Search NASA⌕ Search

SEARCH · Search NASA

Results for “test protocol”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

1,165 records · Page 65

Utah FORGE: Fault Reactivation Through Fluid Injection Induced Seismicity Laboratory Experiments

Included are results from shear reactivation experiments on laboratory faults pre-loaded close to failure and reactivated by the injection of fluid into the fault. The sample comprises a single-inclined-fracture (SIF) transecting a cylindrical sample of Westerly granite. All experiments are conducted at ambient temperature and follow a similar protocol: (i) application of confining stresses (3MPa) on the fault fully saturated with DI water, (ii) shear-mobilization through the increase of axial loading at a constant displacement rate until a post-peak steady-state condition is reached, (iii) reduction of axial loading and related shear stress to a prescribed fraction of the peak steady-state frictional strength (typically 60% to 90%, representing intermediate to high magnitudes) and (iv), fault reactivation triggered by a stepwise increase of pore pressure on the fault in 0.1 MPa increments held constant for 1-5 minutes. Mechanical data from three ISCO pumps connected to a Temco pressure vessel measure axial, confining, and fault-related parameters, including fluid pressure (kPa), fluid flow rate (mL/min), and axial displacement (mm). See included code for initial data analysis and visualization for select experiments. Resource names represent experiment numbers found in the "Read Me" file, which describes each experimental setup and parameters.

15 GEOTHERMAL ENERGY↗

Standardization and best practices in single-cell testing for liquid alkaline water electrolysis

The increasing demand for efficient and sustainable hydrogen production has driven significant advancements in water electrolysis technologies. Among these, liquid alkaline water electrolysis (LAWE) stands out for its cost-effectiveness and scalability. This manuscript establishes best practices and standardized testing procedures for single-cell LAWE, focusing on the use of nickel foam as both anode and cathode substrates, while incorporating catalysts such as nickel-iron layered double hydroxide (NiFe-LDH) as the anode material and nickel-molybdenum on carbon (NiMo/C) as the cathode material. By providing detailed guidelines on material preparation, cell assembly, and performance evaluation, this work offers a comprehensive framework to improve reproducibility and ensure consistency. The results demonstrate that applying these best practices minimizes variability across different laboratories and experimental setups, laying the groundwork for more robust comparisons and accelerating progress in LAWE research.

08 HYDROGEN↗

Anthropogenic Markers in Alta Irrigation District Water Supply Wells

In July 2016, LLNL produced a report for the Kings River Watershed Coalition Authority (KRWCA) entitled “Groundwater Age and Nitrate Isotopic Composition in Alta Irrigation District Water Supply Wells” (Esser et al., 2016). That report summarized groundwater age and nitrate isotopic composition data produced by LLNL for Alta Irrigation District (AID) groundwater wells sampled by KRWCA in a pilot project to test the utility of advanced isotopic methods for constraining the timing and source of nitrate in groundwater at selected sites in the Kings River service area. One section of that report made recommendations for follow-on study. The first and strongest recommendation was to measure a wider suite of source tracers including co-contaminants such as herbicides, pesticides, pharmaceuticals, personal care products, and food constituents and additives. KRWCA followed up on this recommendation in Phase II of the pilot study by re-sampling the original set of wells and submitting the samples to a commercial laboratory for analysis of a limited range of co-contaminants (including pharmaceuticals, personal care products , and food constituents and additives, but not including herbicides or pesticides). They have asked that LLNL review and interpret these data in the context of previous LLNL analyses and to evaluate the utility of such co-contaminant analyses in providing additional constraints on the source of groundwater nitrate contamination in Alta Irrigation District water supply wells. The goal of the second phase of this pilot project is to evaluate the utility of co-contaminant occurrence for constraining nitrate source in groundwater at selected sites in the Kings River service area, with special reference to the use of such data in conjunction with advanced isotopic methods such as nitrate isotopic composition and groundwater age. Nitrate isotopic composition alone cannot distinguish nitrate derived from animal manure from nitrate derived from human septic waste. The presence or absence of agricultural chemicals (herbicides, pesticides, veterinary pharmaceuticals) or chemicals associated with people (human pharmaceuticals, artificial sweeteners) can help make this distinction. Co-contaminant analyses using multi-analyte LC-MS-MS protocols are now commercially available and reasonably priced. The feasibility and utility of the using co-contaminants for nitrate source attribution can be evaluated by 1) determining the degree to which co-contaminants occur in distinct and easily attributable groupings (e.g. agricultural chemicals vs personal care products and food additives); 2) determining the degree to which co-contaminant occurrence is consistent with nitrate isotopic composition and groundwater age (e.g. no co-contaminant occurrence in very old groundwater; co-contaminants consistent with animal manure or human septic waste occurring in groundwaters having nitrate isotopic composition also consistent with animal manure or human septic waste); and 3) determining the degree to which co-contaminants provide additional constraint on nitrate source over and beyond nitrate isotopic composition and groundwater age (e.g. distinguishing between animal manure and human septic waste).

58 GEOSCIENCES↗

SU-F-T-219: Verification of the Accuracy of a Relative Stopping Power (RSP) to Hounsfield Unit (HU) Calibration Curve Produced for Proton Treatment Planning Using EBT3-Gafchromic Film Dosimetry

Purpose: Accuracy of a RSP-HU calibration curve produced for proton treatment planning is tested by comparing the treatment planning system dose grid to physical doses delivered on film by a Mevion S250 double-scattering proton unit. Methods: A single batch of EBT3 Gafchromic film was used for calibration and measurements. The film calibration curve was obtained using Mevion proton beam reference option 20 (15cm range, 10cm modulation). Paired films were positioned at the center of the spread out Bragg peak (SOBP) in solid water. The calibration doses were verified with an ion chamber, including background and doses from 20cGy to 350cGy. Films were scanned in a flatbed Epson-Expression 10000-XL scanner, and analyzed using the red channel. A Rando phantom was scanned with a GE LightSpeed CT Simulator. A single-field proton plan (Eclipse, Varian) was calculated to deliver 171cGy to the pelvis section (heterogeneous region), using a standard 4×4cm aperture without compensator, 7.89cm beam range, and 5.36cm SOBP. Varied depths of the calculated distal 90% isodose-line were recorded and compared. The dose distribution from film irradiated between Rando slices was compared with the calculated plans using RIT v.6.2. Results: Distal 90% isodose-line depth variation between CT scans was 2mm on average, and 4mm at maximum. Fine calculation of this variation was restricted by the dose calculation grid, as well as the slice thickness. Dose differences between calibrated film measurements and calculated doses were on average 5.93cGy (3.5%), with the large majority of differences forming a normal distribution around 3.5cGy (2%). Calculated doses were almost entirely greater than those measured. Conclusion: RSP to HU calibration curve is shown to produce distal depth variation within the margin of tolerance (±4.3mm) across all potential scan energies and protocols. Dose distribution calculation is accurate to 2–4% within the SOBP, including areas of high tissue heterogeneity.

07 ISOTOPE AND RADIATION SOURCES↗

Environmental Restoration of Diesel-Range Organics from Project Chariot, Cape Thompson, Alaska - 16147

Cape Thompson, Alaska, is located approximately 120 miles north of Kotzebue, Alaska, within the Ogotoruk Creek valley. The remote Alaskan location is also home to the US Atomic Energy Commission (AEC) Project Chariot study area. Project Chariot was part of the Plowshare Program, created in 1957 by the AEC to study peaceful uses for atomic energy. Project Chariot began in 1958 when a scientific field team chose Cape Thompson as a potential site to excavate a harbor using a series of nuclear explosions. Between 1959 and 1962, AEC was responsible for over 40 pretest bio-environmental and geotechnical studies of the Cape Thompson area. Strong public opposition to the tests developed, which caused the project to be cancelled with no nuclear explosions ever conducted at the site. In the early 1960's, several deep boreholes were drilled to obtain subsurface, temperature, and high-explosive testing data. Refrigerated diesel was used as a drilling fluid to keep the boreholes open so that thermistors could measure subsurface temperatures. The test boreholes were named Able, Baker, Charlie, Dog, and X-1. In the summer of 2014, the US Department of Energy, Office of Legacy Management (LM) completed the remediation of remnant diesel at these sites. Prior to the 2014 remediation activities, LM conducted two separate characterization field studies to determine the nature and extent of the contamination from the 1960's drilling activities. In 2013, LM developed a remediation plan that was submitted and approved by the Alaska Department of Environmental Conservation (ADEC). The 2014 Project Chariot remediation had some unique logistical challenges and historic issues with stakeholders to overcome. Many of the historic issues centered on previous AEC scientific actions and a general mistrust of the government by the local stakeholders. Prior to and during the 2014 remediation work, an outreach campaign was implemented to discuss prior activities at the site and include stakeholders from Point Hope, Alaska, in the remediation-planning process. The remoteness of the region also provided unique logistical challenges. Because of the short field season, LM initiated several subcontracts over a year in advance. The field camp, heavy equipment, and soil storage containers were shipped by barge to the site. Personnel, food, and small materials were flown in by bush plane from Kotzebue, Alaska. Previous site characterization had identified diesel-range organics (DROs) as the primary contaminant. The cleanup levels for the site were provided by the Alaska Administrative Code (AAC) for the Arctic Zone region. The AAC cleanup level for DROs on gravel pads is 500 mg/kg and 12,500 mg/kg tundra in the arctic-zone region. To help determine the extent and direct soil excavation in the field, photoionization detectors (PIDs) were used for field screening. While the PID results provided rough limits for excavation, laboratory confirmation sampling was required to provide actual excavation guidance. All excavation locations remained open until laboratory results met AAC criteria and ADEC approved closure. The laboratory sample protocol required the bush plane to pick up samples almost daily and transfer them to Anchorage for analysis. In order to meet holding time requirements, all laboratory samples were analyzed on an expedited basis. Analytical results and ADEC approval notifications were e-mailed back to the site via satellite connection. A total of 202 laboratory analyses were needed to complete the remediation effort. At each location (Able, Baker, Charlie, Dog, and X-1), the boreholes were plugged and abandoned in accordance with ADEC regulations. Contaminated soil was excavated, and the material was placed in super-sacks and hauled to connex boxes located near the sea shore. Approximately 786 tons of material was removed and shipped by barge to the Columbia Ridge Landfill in Arlington, Oregon, for disposal. The well casings were cut and sealed below ground surface. Each location was graded to its original contours and reclaimed with native vegetation, and a geodetic survey was conducted. Tours with leaders of the Village of Point Hope and the land owner (Arctic Slope Regional Corporation) were conducted prior to the final demobilization. All remediation equipment and camp facilities were removed at the completion of the project. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Preservation of rat hearts in subfreezing temperature isochoric conditions to – 8 °C and 78 MPa

Highlights: • A novel method of low-temperature organ preservation is tested using rat hearts. • Isochoric systems allow ice-free preservation at temperatures well below freezing. • Conventional heart preservation employs on-ice storage in atmospheric conditions. • Histological quality is improved in hearts preserved in a −4 °C isochoric system. Isochoric (constant volume) preservation at subfreezing temperatures is being investigated as a novel method for preserving cells and organs. This study is a first initial effort to evaluate the efficacy of this method for heart preservation, and to provide a preliminary outline of appropriate preservation parameters. To establish a baseline for further studies, rat hearts were preserved in a University of Wisconsin (UW) intracellular solution for one hour under isochoric conditions at: 0 °C (atmospheric pressure - 0.1 MPa), - 4 °C (41 MPa), - 6 °C (60 MPa) and – 8 °C (78 MPa). The viability of the heart was evaluated using Langendorff perfusion and histological examination. The physiological performance of hearts preserved at – 4 °C (41 MPa) was comparable to that of a heart preserved on ice at atmospheric pressure, with no statistically significant difference in histological injury score. However, hearts preserved at −4 °C displayed substantially reduced interstitial edema compared to hearts preserved by conventional hypothermic preservation in UW on ice at atmospheric pressure, suggesting significant protection from increased vascular permeability following preservation. Hearts preserved at – 6 °C (60 MPa) suffered injury from cellular swelling and extensive edema, and at – 8 °C (78 MPa) hearts experienced significant morphological disruption. To the best of our knowledge, this is the first publication showing that a mammalian organ can survive low subfreezing temperatures without the use of a cryoprotective additive. Lowering the preservation temperature reduces metabolism and improves preservation quality, and these results suggest that improvements in preservation are possible at subzero temperatures with low to moderate pressures observed at −4 °C. Notably, tissue damage was observed at lower temperatures (−6 °C or below) accompanying further elevation of pressure associated with isochoric preservation that may prove detrimental. Therefore, subfreezing temperature isochoric preservation protocols should optimize, a combination of temperature and pressure that will minimize the negative effects of elevated pressure while retaining the beneficial effect of lower temperatures and reduced metabolism.

60 APPLIED LIFE SCIENCES↗

Deep learning and radiomics: the utility of Google TensorFlow™ Inception in classifying clear cell renal cell carcinoma and oncocytoma on multiphasic CT

Purpose: Currently, all solid enhancing renal masses without microscopic fat are considered malignant until proven otherwise and there is substantial overlap in the imaging findings of benign and malignant renal masses, particularly between clear cell RCC (ccRCC) and benign oncocytoma (ONC). Radiomics has attracted increased attention for its utility in pre-operative work-up on routine clinical images. Radiomics based approaches have converted medical images into mineable data and identified prognostic imaging signatures that machine learning algorithms can use to construct predictive models by learning the decision boundaries of the underlying data distribution. The TensorFlow™ framework from Google is a state-of-the-art open-source software library that can be used for training deep learning neural networks for performing machine learning tasks. The purpose of this study was to investigate the diagnostic value and feasibility of a deep learning-based renal lesion classifier using open-source Google TensorFlow™ Inception in differentiating ccRCC from ONC on routine four-phase MDCT in patients with pathologically confirmed renal masses. Methods: With institutional review board approval for this 1996 Health Insurance Portability and Accountability Act compliant retrospective study and a waiver of informed consent, we queried our institution’s pathology, clinical, and radiology databases for histologically proven cases of ccRCC and ONC obtained between January 2000 and January 2016 scanned with a an intravenous contrast-enhanced four-phase renal mass protocol (unenhanced (UN), corticomedullary (CM), nephrographic (NP), and excretory (EX) phases). To extract features to be used for the machine learning model, the entire renal mass was contoured in the axial plane in each of the four phases, resulting in a 3D volume of interest (VOI) representative of the entire renal mass. We investigated thirteen different approaches to convert the acquired VOI data into a set of images that adequately represented each tumor which was used to train the final layer of the neural network model. Training was performed over 4000 iterations. In each iteration, 90% of the data were designated as training data and the remaining 10% served as validation data and a leave-one-out cross-validation scheme was implemented. Accuracy, sensitivity, specificity, positive (PPV) and negative predictive (NPV) values, and CIs were calculated for the classification of the thirteen processing modes. Results: We analyzed 179 consecutive patients with 179 lesions (128 ccRCC and 51 ONC). The ccRCC cohort had a mean size of 3.8 cm (range 0.8–14.6 cm) and the ONC cohort had a mean lesion size of 3.9 cm (range 1.0–13.1 cm). The highest specificity and PPV (52.9% and 80.3%, respectively) were achieved in the EX phase when we analyzed the single mid-slice of the tumor in the axial, coronal and sagittal plane, and when we increased the number of mid-slices of the tumor to three, with an accuracy of 75.4%, which also increased the sensitivity to 88.3% and the PPV to 79.6%. Using the entire tumor volume also showed that classification performance was best in the EX phase with an accuracy of 74.4%, a sensitivity of 85.8% and a PPV of 80.1%. When the entire tumor volume, plus mid-slices from all phases and all planes presented as tiled images, were submitted to the final layer of the neural network we achieved a PPV of 82.5%. Conclusions: The best classification result was obtained in the EX phase among the thirteen classification methods tested. Our proof of concept study is the first step towards understanding the utility of machine learning in the differentiation of ccRCC from ONC on routine CT images. We hope this could lead to future investigation into the development of a multivariate machine learning model which may augment our ability to accurately predict renal lesion histology on imaging.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Materials Challenges and Opportunities for Energy Generation, Conversion, Delivery, and Storage (Applied Energy Tri-Laboratory Consortium Workshop Report)

This report documents the outcomes of the Tri-Laboratory Materials Workshop that was held July 31 and August 1, 2019 to begin addressing the needs, opportunities, and challenges associated with the development, fabrication, and testing of the needed materials and components for integrated hybrid energy systems (i.e., incorporating nuclear, fossil, and renewables for electric and thermal applications). This was accomplished by assembling the research program leads and principal investigators at Idaho National Laboratory (INL), National Energy Technology Laboratory (NETL), and National Renewable Energy Laboratory (NREL), who support the research and development of new technology and system integration. The team then identified and prioritized key materials development needs. This effort was intended to enhance communications and synergy among the Tri-Lab partners. Advanced functional and structural materials are central to transformative energy technologies for energy generation, conversion, delivery, and storage. With that in mind, the workshop focused on identifying and assessing the foundational materials research needs at both the basic and applied levels. Materials challenges include the ability to withstand harsh environments, such as high temperatures and pressures, corrosion, oxidation, or irradiation while maintaining flexible mission profiles and long service lifespans. Advanced energy system material challenges and needs range from materials for the capture, upgrading/concentration, storage, and delivery of low-grade heat to materials for high temperature environments that involve liquid metals, molten salt, and very high temperature gas heat delivery and storage systems. Material improvements are needed for hybrid energy systems due to accelerated corrosion and stress-fatigue failure of materials and equipment, which results from increased frequency and amplitude of thermal, mechanical, and electrical cycling of systems components. Multifunctional materials are needed for high temperature solid-oxide fuel cells, advanced electrochemical reactors, and in-process separation. Relative to materials manufacturing, application of advanced additive and subtractive methods need to be understood to develop both thin-layer homogenous materials and materials of graded composition. Materials modeling and machine learning will be critical to accelerate the design and production of power electronics, and nuclear reactor materials and fuel, as well as to gain an understanding of beneficial materials phenomena or deleterious microstructure evolution. There is also a need for standardized models, computational structures, data reporting protocols and modeling tools across the three laboratories. This would allow consistent results, analysis, and data sharing. Combining computational capabilities between the three laboratories (e.g., hardware, software) would greatly increase computational capabilities and throughput. The workshop identified the need for laboratories to anticipate and address problems that will occur during scale-up. Laboratory work must connect with industry to ensure that research focuses on processes that are scalable and marketable. Industry input and perspective are essential to guide laboratory research to meet these requirements and deploy new technology in industrial demonstrations. Another aspect of scale-up is the integration of multiple systems since new challenges often arise at the subsystem interfaces. Establishing a scale-up manufacturing demonstration/pilot plant, potentially as an industrial user facility, would be beneficial to the laboratories and industry. That modular scale-up manufacturing demonstration/pilot plant would allow researchers to find and resolve interface problems that cannot be identified by focusing only on individual parts. Communication exchanges among the organizers, attendees, and workshop survey responses indicate that the workshop was successful in achieving its goal to identify key technology gaps and research needs. Strong positive feedback was received on the sharing of ideas, capabilities, talent, and passion to move forward on the materials-related action items.

36 MATERIALS SCIENCE↗

Biological toxicity and environmental hazards associated with PLGA nanoparticles

There have been tremendous advances in nanotechnology. More recently, the use of nanoparticles has expanded to applications including materials, packaging, energy, and medical uses such as drug delivery, diagnostics, and therapeutics. The American Society for Testing and Materials (ASTM) and the International Organization for Standardization (ISO) define nanoparticles as particles with at least one dimension measuring between 1 and 100 nm (2), but this view is generally too limited, and recommendations have been made to consider all materials with a dimension measuring under 1,000 nm as nanoparticles. The biomedical uses of nanoparticles are particularly promising because of their ability to reach and target various sites and organs. However, some nanoparticles can be composed of toxic materials or are limited by issues of biodistribution and bioaccumulation, which have hampered their use in biomedicine. The copolymer poly lactic-co-glycolic acid (PLGA) has gained use in biomedical applications as a delivery system because it is considered biocompatible and can be formulated with controlled degradation in physiological environments. PLGA has a history in biomedicine that dates to the 1970s when biodegradable sutures were developed using PLGA. In addition, the United States (US) Food and Drug Administration (FDA) and the European Medicine Agency (EMA) have approved various PLGA particle formulations as therapeutic delivery vehicles. Interest in biocompatible materials to deliver a range of therapeutic drugs, proteins, nucleic acids, and other molecules has risen recently. In addition to drug delivery, sustained drug release can be achieved by tuning the physical properties of PLGA, such as the molecular weight, ratio of lactic to glycolic acid, drug concentration, stabilizing molecules, and particle size. Given the rise of nanoparticles, human and environmental exposure to them is inevitable as more applications use free, unbound, and highly mobile particles. Although PLGA is generally considered safe, a detailed understanding of how PLGA and the other components used to help formulate this copolymer into a nanoparticle delivery vehicle is useful for assessing potential harmful effects. Despite recent advances in PLGA nanoparticle formulations, residual stabilizing molecules, inconsistent preparations, and batch-to-batch variations can lead to toxicity. Poor preparations of PLGA can lead to common mechanisms of toxicity observed with nanoparticles, such as inflammation and oxidative stress. Consistency in PLGA formulations and accurate methods to evaluate nanoparticle toxicity are needed to ensure safety. In order to better assess PLGA nanoparticles as non-toxic delivery systems, it is critical to understand their physical and chemical properties and the formulation protocols that may introduce toxic components into particles.

Biology, nanoparticle, toxicity↗

Nanoscale structural evolution and phase transformation of geopolymers: In situ SAXS/WAXS investigation under uniaxial tension at elevated temperatures

This investigation delves into the degradation mechanisms of high-density polyethylene geomembranes (PE GMXs) under a spectrum of conditions, replicating real-world scenarios within a rigorously controlled laboratory setting. The treatment protocols applied induced a notable increase in the crystallinity of the treated specimens relative to the untreated controls. Small-angle x-ray scattering (SAXS) analysis identified an initial long period (interlamellar distance) of 16.9 nm for the untreated polymer, which expanded by 19.5% at a strain of 16.7 percent. Conversely, the treated PE GMXs exhibited a more gradual elongation of the long period, with an increase of merely 10.6% at a strain of 23.3 percent. At an elevated temperature of 65°C, both samples exhibited pronounced strain hardening, with the treated PE GMXs demonstrating superior stability even at a strain of 150 percent. Wide-angle x-ray scattering (WAXS) experiments corroborated these observations, revealing that the diffraction patterns of the untreated PE remained stable up to a strain of 16.7%, whereas those of the treated PE remained distinct up to a strain of 46.1 percent. Scanning electron microscopy (SEM) images substantiated the formation of a shish–kebab structure in the treated samples. The study concludes that the geopolymer underwent oxidation and material degradation as a result of the chemical and mechanical treatments, transitioning to a more crystalline state and concomitantly losing its initial elasticity.

36 MATERIALS SCIENCE↗

The Nuclear Energy Knowledge and Validation Center – Summary of Activities Conducted in FY15

The Nuclear Energy Knowledge and Validation Center (NEKVaC) is a new initiative by the Department of Energy and the Idaho National Laboratory to coordinate and focus the resources and expertise that exist with the DOE Complex toward solving issues in modern nuclear code validation. In time, code owners, users, and developers will view the Center as a partner and essential resource for acquiring the best practices and latest techniques for validating codes, for guidance in planning and executing experiments, for facilitating access to, and maximizing the usefulness of, existing data, and for preserving knowledge for continual use by nuclear professionals and organizations for their own validation needs. The scope of the center covers many inter-related activities which will need to be cultivated carefully in the near-term and managed properly once the Center is fully functional. Three areas comprise the principal mission: 1) identification and prioritization of projects that extend the field of validation science and its application to modern codes, 2) adapt or develop best practices and guidelines for high fidelity multiphysics/multiscale analysis code development and associated experiment design, and 3) define protocols for data acquisition and knowledge preservation and provide a portal for access to databases currently scattered among numerous organizations. These mission areas, while each having a unique focus, are inter-dependent and complementary. Likewise, all activities supported by the NEKVaC, both near-term and long-term), must possess elements supporting all three. This cross-cutting nature is essential to ensuring that activities and supporting personnel do not become ‘stove-piped’, i.e. focused so much on a specific function that the activity itself becomes the objective rather than the achieving the larger vision. Achieving the broader vision will require a healthy and accountable level of activity in each of the areas. This will take time and significant DOE support. Growing too fast (budget-wise) will not allow ideas to mature, lessons to be learned, and taxpayer money to be spent responsibly. The process should be initiated with a small set of tasks, executed over a short but reasonable term, that will exercise most if not all aspects of the Center’s potential operation. The initial activities described in this report have a high potential for near-term success in demonstrating Center objectives but also to work out some of the issues in task execution, communication between functional elements, and the ability to raise awareness of the Center and cement stakeholder buy-in. This report begins with a description of the Mission areas; specifically the role played by each and the types of activities for which they are responsible. It then lists and describes the proposed near-term tasks upon which future efforts can build.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Layer-by-layer deposition of ultra-thin hybrid/microporous membrane for CO 2 separation

Based on two issued US patent, US7947579B2 and US8187678B2 that were invented by our team member at the University of New Mexico and Sandia National Labs, using atomic layer deposition technique (ALD) and molecular self-assembly or templating technique, An ultra-thin CO 2 membrane with CO 2 permeance up to 1580 GPU and CO 2 /N 2 up to 62 has been achieved in phase I project, promising for cost-effective CO 2 separations. As the first step of the project, a robust membrane fabrication protocol was established. To address the defects in the membrane structure, ALD treatment on AO support, multiple dip-coating processes and slow calcination steps were adopted. Consequently, defects were no longer evident in the nanoporous support, which ensures a reliable procedure for lab-scale membrane fabrications as well as the high-fidelity experimental findings. The same procedures may also be helpful for future scaling-up protocols. The layer-by-layer membrane fabrication was started by using a bridged disilane BTEE as the ALD precursor, wherein the organic groups at the bridging site were expected to be aligned layer-by-layer to form Angstrom-channels for CO 2 transport. Using 2-level factorial experimental design, we have found that ALD reaction time and ALD temperature were important factors impacting the CO 2 permeance and selectivity. Longer reaction time and higher ALD temperature were found to be advantageous for better CO 2 permeance and selectivity, which is in agreement with our model that better-aligned CO 2 -channels formed by the layer-by-layer stacking of the organic ligands can be achieved by a slower “stacking” process (longer reaction time) and stronger self-alignment tendency (higher ALD temperature). This observation will be an important guidance for our future membrane designs. The CO 2 -channel templated by –(CH 2 ) 2 - in BTEE was found to be too tight to facilitate fast CO 2 transport, but larger channel diameter is in contradiction with higher CO 2 selectivity. Therefore, the size-exclusion mechanism by itself is not sufficient for effective CO 2 separation. For this reason, the chemistry of the CO 2 -channel has to be carefully tuned. An amine bridged-disilane BTMA was therefore used as ALD precursor for larger CO 2 channel and high CO 2 -affinity chemistry. For BMTA membrane with amine chemistry measured at 100C, the CO 2 permeance was 1030 GPU for 100-cycle-ALD sample with CO 2 /N 2 selectivity of 17, and 302 GPU for 200-cycle-ALD sample with CO 2 /N 2 selectivity of 44. The increase of CO 2 permeance and the CO 2 /N 2 selectivity at elevated temperature is an evidence showing that there is a preferential chemical interaction between CO 2 and –NH functional groups in the membrane, which facilitates selective transport of CO 2 through the membrane. Therefore, using larger organic ligands as the CO 2 -channel template and the introduction of –NH chemistry to the membrane structure were proved to be an effective strategy in achieving better CO 2 permeance and selectivity. Guided by the same strategy, BTMA membrane was irradiated with UV to remove the bridging ligands for larger CO-channel, followed by Zn 2+ and Ni 2+ chemistry modification. Results showed that Zn 2+ or Ni 2+ chemistries will both enhance the selective CO 2 transport thereby the CO 2 /N 2 selectivity, and increasing separation temperature will further improve the CO2 permeance and selectivity. For BTMA membrane with Ni 2+ chemistry measured at 100C, CO 2 permeance of 1580 GPU and CO 2 /N 2 of 62 were achieved, promising for scaled-up industrial applications. Further, same membrane was tested at simulated flue gas condition (with SO 2 at 60C), the CO 2 permeance was 920 GPU and the CO 2 /N 2 selectivity was 52, suggesting the membrane still worked well under simulated flue gas conditions, primarily due to the stable ceramic framework of this membrane.

36 MATERIALS SCIENCE↗

Novel Carbon (C)-Boron (B)-Nitrogen (N)-Containing H2 Storage Materials

The following summarizes the research conducted for DOE project DE-EE0005658 “Novel Carbon(C)-Boron(B)-Nitrogen(N)-Containing H2 Storage Materials”. This work focused in part on the continued study of two materials identified from the preceding project DE-FG360GO18143 (“Hydrogen Storage by Novel CBN Heterocycle Materials”) as lead candidates to meet the DOE technical targets for either vehicular or non-automotive hydrogen storage applications. Specifically, a room-temperature liquid, 3-methyl-1,2-cyclopentane (B), and a high H2 capacity solid, 1,2-BN-cyclohexane (J), were selected for further characterization and performance optimization. In addition to these compounds, the current project also aimed to prepare several new materials predicted to be disposed towards direct reversibility of H2 release and uptake, a feature deemed critical to achieving efficient recycling of spent fuel end products. To assist in the rational design of these and other next-generation materials, this project undertook to investigate the mechanism of hydrogen release from established compounds (mainly B and J) using a combined experimental/computational approach. Among this project’s signature accomplishments, the preliminary synthetic route to B was optimized for production on decagram scale. With such quantities of material available, its performance in powering an actual 30 W proton exchange membrane (PEM) fuel cell stack was tested and found to be identical to that of facility H2. Despite this positive proof-of-concept achievement, however, further consideration of neat B as a potential hydrogen storage material was abandoned due to evidence of thermal instability. Specifically, mass spectrometry-coupled thermogravimetric analysis (TGA-MS) revealed significant H2 release from B to initiate at 50 °C, well below the 60 °C minimum threshold set by the DOE. This result prompted a more extensive investigation in the decomposition mechanism of B vis-à-vis that of J, which exhibited in neat form a substantially higher onset temperature for spontaneous H2 release (70 °C). Solution-phase kinetic experiments using ReactIR established a second-order dependence for the initial loss of H2 from both B and J; Arrhenius analysis, however, revealed the activation barrier for this reaction was lower for B than for J, which presumably contributes to the diminished thermal stability of the former. On the basis of these and other experimental results, extensive computational efforts yielded a reasonable mechanistic model for the dehydrogenation of 1,2-BN-cycloalkane materials. While the prospect of neat B as a suitable hydrogen storage material was discarded, it was proposed that the combination of B with more thermally stable amine-borane-based materials might afford mixtures with improved properties. Indeed, when B was combined with ammonia borane (AB) in a 2:1 molar ratio, the two materials formed a liquid. More significantly, this mixture remained liquid even after complete dehydrogenation, thus establishing the potential for a single-phase fuel cycle. (In contrast, the dehydrogenation product of neat B is a low melting solid (mp = 28-30 °C).) Another advantage conferred by the blend formulation was a dramatic reduction in the amount of borazine produced by AB. Borazine is a well-known contaminant of H2 produced by the thermal decomposition of neat AB, and exerts deleterious effects on fuel cell performance. Residual gas analysis (RGA) of the gas stream generated from the B-AB blend, however, detected just 0.01% borazine content when a Pt-Ni nanoparticle dehydrogenation catalyst was used. In all ii then, the 2:1 B-AB blend marks a major achievement in the effort to develop a suitable liquid amine-borane hydrogen storage material, and merits further investigation into the optimization for practical adoption. Similar realization of the potential of J as a high % wt. H2 material required a method to dehydrogenate the carbonaceous components of the molecule without the use of a sacrificial hydrogen acceptor, as had been reported in the previous project. Ultimately, this reaction was achieved for a B,N-disubstituted BN-cyclohexene model substrate using a gas flow system with a fixed Pd/C catalyst bed. Considerable work remains, however, to translate these initial results into a general protocol for complete dehydrogenation of fully saturated BN-cycloalkane materials such as J. With concrete confirmation of the possibility to perform both BN and CC dehydrogenation on a single theoretical substrate, COMSOL modeling was used to evaluate the effects of thermodynamically coupling the two reactions. It was hypothesized that the heat generated from exothermic BN dehydrogenation would partially drive the endothermic CC dehydrogenation reaction; this additional heat consumption was expected to in turn confer the benefit of lowering the maximum reactor temperature. A two-dimensional model of an axisymmetric reactor including experimental kinetic and calculated thermodynamic parameters for both reactions did indeed predict these outcomes. The extent to which the effects of thermodynamic coupling actually manifested, however, were also revealed to depend strongly on the relative rates of the two reactions, as well as the magnitude of the equilibrium constant governing the progress of the endothermic process. Given the evident complexity of attaining high effective % wt. H2 capacity with J, alternative systems were investigated for greater facility of extensive H2 release. Among those studied, 1,2,4,5-bis-BN-cyclohexane (H) demonstrated the most favorable properties, particularly with respect to thermal stability: rather than decompose, a neat sample instead sublimed when heated above 150 °C. Nevertheless, two commercially available catalytic systems were identified to effect release of two H2 equivalents from H. Release of further equivalents were apparently impeded by the formation of either polymeric material or one of two dimeric cage compounds depending on the catalyst used. Notably, a method to regenerate H from these product mixtures remains to be developed. Thus, while H may prove useful for certain long-term energy storage needs, it is currently less suited applications involving frequent fuel consumption. Similar difficulties were also encountered in attempts to realize the complete fuel cycle of 1,3-BN-cyclohexane (E) and B,N-substituted derivatives thereof. It had been initially proposed that E would provide for readily reversible BN dehydrogenation through a measure of frustrated Lewis pair-type character. Indeed, computations predicted this reaction would be essentially thermoneutral in solution. In the course of attempts to fully hydrogenate the spent fuel, however, dimeric species formed and proved resistant to further BN reduction. While a number of monomeric cyclic compounds were also successfully synthesized as formal boron-nitrogen frustrated Lewis pairs, none demonstrated any capacity to split H2 across the BN unit. The challenge of developing a practical amine-borane-based material for readily reversible hydrogen storage thus remains unresolved at this time. As such, it deserves consideration as a major objective of any future work.

08 HYDROGEN↗