At least 1,171 records · Page 65

Modeling MTS pyrolysis and SiC deposition kinetics using principal component analysis and neural networks

Accurate chemical kinetics modeling is crucial for improving the efficiency of chemical processing and synthesis of ceramic matrix composites. Detailed kinetic models are computationally expensive due to the large number of transported chemical species, while the simplified physics-based models, such as single-step global mechanisms, are efficient but often overlook key chemical intermediates and pathways. Recent deep learning approaches promise accurate and cost-effective models. Yet, they require additional closures for the transported nonlinear latent variables, complicating integration with existing solvers. In this work, we develop a hybrid linear—nonlinear reduced model for silicon carbide deposition from methyltrichlorosilane precursor by combining principal component analysis (PCA) and autoencoder (AE) neural network (NN) approaches. PCA is used to identify a smaller set of linear transport variables, enabling direct reuse of conventional transport solvers. NNs then reconstruct the full chemical state from these reduced variables. We demonstrate the method on a chemical vapor deposition reactor—comprising a gas-phase pyrolysis plug flow reactor and a heterogeneous surface reactor—over a wide range of temperatures, pressures, and residence times. Our PCA–AE model achieves high accuracy with only five transported scalars, achieving an eightfold cost reduction compared to detailed mechanisms, in both a priori (using data from the test set only) and a posteriori (coupled with a differential equation solver). In conclusion, notable errors arise primarily near training domain boundaries and for long residence times, indicating the need for domain shift indicators and better long-horizon predictions in future reduced chemistry model development.

autoencoder neural networks↗

Laminar flame and acoustic waves in two-dimensional flow

The complete system of fluid dynamics equations describing the development of instability of a reaction front in a two-dimensional flow in reversed time are reduced to a closed system of equations of front dynamics by using Lagrangian variables and integrals of motion. The system can be used to analyze processes behind the front without solving the complete system of fluid dynamics and chemical kinetics equations. It is demonstrated how the gas density disturbances induced by the moving front can be described in the adiabatic approximation.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Improving Process Level Understanding of Boundary Layer Winds over the Northeast U.S. Shelf: The Third Wind Forecast Improvement Project (WFIP3)

The third Wind Forecast Improvement Project (WFIP3), a U.S. Department of Energy and National Oceanic and Atmospheric Administration sponsored investigation, sought to improve understanding of the physical phenomena in the atmosphere and ocean that dictate the structure and variability of wind and thermodynamic fields within the marine atmospheric boundary layer. WFIP3 focused on mesoscale and submesoscale flows -- including sea breezes, low-level jets, low-level clouds, and coastal storms -- and the ability of advanced numerical model parameterizations to represent them within fully coupled oceanic and atmospheric modeling systems and foundational weather forecast models. WFIP3 conducted a comprehensive 18-month observational study over the Northeast U.S. outer continental shelf, a high-use coastal zone, using a 3D multiscale sensor array to highly resolve the temporal, vertical, and horizontal structure of the coupled atmospheric and oceanic boundary layers. Multiple land-based study sites adjacent to the coastal ocean observed surface meteorology and vertical profiles of atmospheric properties via passive infrared and microwave radiometers, active lidars and radars, and radiosondes. At sea, an array of surface flux buoys and two vertical profiling lidar buoys observed both atmospheric and oceanic properties, augmented by land-based oceanographic radar systems and routine ship-based surveys. Intensive observations of the marine atmospheric boundary layer over the ocean was done from an air-sea interaction flux tower and extended deployments of a large autonomous barge platform. Numerous critical forecasting phenomena were observed that are being evaluated within regional coupled and uncoupled modeling systems, including the National Oceanic and Atmospheric Administration's foundational High-Resolution Rapid Refresh forecast model.

Kirincich, Anthony↗

Evaluating Global Streamflow Simulations by a Physically-based Routing Model Coupled with the Community Land Model

Accurately simulating hydrological processes such as streamflow is important in land surface modeling because they can influence other land surface processes, such as carbon cycle dynamics, through various interaction pathways. This study aims to evaluate the global application of a recently developed Model for Scale Adaptive River Transport (MOSART)coupled with theCommunity Land Model, version 4 (CLM4). To support the global implementation of MOSART, a comprehensive global hydrography dataset has been derived at multiple resolutions from different sources. The simulated runoff fields are first evaluated against the composite runoff map from theGlobal RunoffData Centre (GRDC). The simulated streamflow is then shown to reproduce reasonably well the observed daily andmonthly streamflow at over 1600 of the world’smajor river stations in terms of annual, seasonal, and daily flow statistics. The impacts of model structure complexity are evaluated, and results show that the spatial and temporal variability of river velocity simulated byMOSART is necessary for capturing streamflow seasonality and annual maximum flood. Other sources of the simulation bias include uncertainties in the atmospheric forcing, as revealed by simulations driven by four different climate datasets, and human influences, based on a classification framework that quantifies the impact levels of large dams on the streamflow worldwide.

global evaluation, routing model, community land m↗

Utah FORGE: Pump and Probe Test on an Intact Westerly Granite Sample

This dataset contains results from a pump and probe experiment conducted on an intact Westerly Granite sample with a diameter of 1 inch and a height of 1 3/8 inches. The experiment was performed within an aluminum triaxial pressure vessel (TEMCO) to investigate the non-linear acoustic parameters of the sample under varying axial pressures. The confining pressure was maintained at 4 MPa, while the axial pressure was incrementally increased from 1 MPa to 17 MPa before being reduced back to 1 MPa. 5 dynamic pressure oscillations of 0.5 MPa were applied over a 10 minute interval. The dataset includes pump controller data, linear variable differential transformer (LVDT) measurements, and acoustic data. The pump controller data tracks the confining and axial pressures, flow rates, and pump volumes. LVDT measurements provide detailed records of the axial displacement of the cell piston. Additionally, acoustic data captured by s-wave transducers is archived in a compressed file.

15 GEOTHERMAL ENERGY↗

Utah FORGE: Pump and Probe Test on a Mated Fracture Westerly Granite Sample

This dataset contains results from a pump and probe experiment conducted on a mated fracture Westerly Granite sample with a diameter of 1 inch and a height of 2 7/8 inches. The experiment was performed within an aluminum triaxial pressure vessel (TEMCO) to investigate the non-linear acoustic parameters of the sample under varying axial pressures. The confining pressure was maintained at 4 MPa, while the axial pressure was incrementally reduced from 17 MPa to 1 MPa in 1 MPa steps. 5 dynamic pressure oscillations of 0.5 MPa were applied over a 10 minute interval. The dataset includes pump controller data, linear variable differential transformer (LVDT) measurements, and acoustic data. The pump controller data tracks the confining and axial pressures, flow rates, and pump volumes. LVDT measurements provide detailed records of the axial displacement of the cell piston. Additionally, acoustic data captured by s-wave transducers is archived in a compressed file.

15 GEOTHERMAL ENERGY↗

WECC Variable Generation Planning Reference Book: Appendices

The document titled “WECC Variable Generation Planning Reference Book”. This book is divided into two volumes; one is the main document (volume 1)and the other is appendices (volume 2). The main document is a collection of the best practices and the information regarding the application and impact of variables generation on power system planning. This volume (appendices) has additional information on the following topics: Probabilistic load flow problems. 2. Additional useful indices. 3. high-impact low-frequency (HILF) events. 4. Examples of wide-area nomograms. 5. Transmission line ratings, types of dynamic rating methods. 6. Relative costs per MW-km of different electric power transmission technologies. 7. Ultra-high voltage (UHV) transmission. 8.High voltage direct current (VSC-HVDC). 9. HVDC. 10. Rewiring of existing transmission lines. 11. High-temperature low sag (HTLS) conductors. 12. The direct method and energy functions for transient stability analysis in power systems. 13.Blackouts caused by voltage instability. 14. Algorithm for parameter continuation predictor-corrector methods. 15. Approximation techniques available for security regions. 16. Impacts of wind power on power system small signals stability. 17. FIDVR. 18. FACTS. 19. European planning standard and practices. 20. International experience in wind and solar energy sources. 21. Western Renewable Energy Zones (WREZ). 22. various energy storage technologies. 23. demand response. 24. BA consolidation and cooperation options. 25. generator power management requirements and 26. European planning guidelines.

Makarov, Yuri V.↗

High temperature high velocity direct power extraction using an open-cycle oxy-combustion system

The implementation of oxy-fuel technology in fossil-fuel power plants may contribute to increased system efficiencies and a reduction of pollutant emissions. One technology that has potential to utilize the temperature of undiluted oxy-combustion flames is open-cycle magnetohydrodynamic (MHD) power generators. These systems can be configured as a topping cycle and provide high enthalpy, electrically conductive flows for direct conversion of electricity. This report presents the design and modeling strategies of a MHD combustor operating at temperatures exceeding 3000 K. Throughout the study, computational fluid dynamics (CFD) models were extensively used as a design and optimization tool. A lab-scale 60 kWth model was designed, manufactured and tested as part of this project. A fully-coupled numerical method was developed in ANSYS FLUENT to characterize the heat transfer in the system. This study revealed that nozzle heat transfer may be predicted through a 40% reduction of the semi-empirical Bartz correlation. Experimental results showed good agreement with the numerical evaluation, with the combustor exhibiting a favorable performance when tested during extended time periods. A transient numerical method was employed to analyze fuel injector geometries for the 60-kW combustor. The ANSYS FLUENT study revealed that counter-swirl inlets achieve a uniform pressure and velocity ratio when the ports of the injector length to diameter ratio (L/D) is 4. An angle of 115 degrees was found to increase distribution efficiency. The findings show that this oxy-combustion concept is capable of providing a high-enthalpy environment for seeding, in order to render the flow to be conductive. Based on previous findings, temperatures in the range of 2800-3000 K may enable magnetohydrodynamic power extraction. The heat loss fraction in this oxy-combustion system, based on CFD and analytical calculations, at optimal operating conditions, was estimated to be less than 10 percent. Furthermore, the heat transfer design removed approximately 7 MW/m2. The results observed in the lab-scale system were employed to develop a 1-MW scaled prototype. Scaling methods were based on critical design criteria found in similar systems, aimed at replicating combustion flow fields and reducing possible instabilities. A numerical simulation of the combustor wall was developed for a combined thermal steady model and static structural model. This combined model was developed predict combined stress parameters within the wall during testing conditions. Both models were developed within ANSYS FEA software package. The relative accuracy presented as well major performance parameters are discussed to assess the design's validity and ensure safety. The scaled prototype was manufactured through selective laser melting (SLM)-based additive manufacturing to reduce lead times and increase geometrical complexity. Additional CFD models were developed to optimize coolant manifold system parameters and perform a parametric study on channel geometry. An investigation on coolant manifold geometry demonstrated improvements in channel flow distribution when enlarging manifold lengths and increasing the number of tubes feeding into the flow. A three-dimensional model based on a single channel was developed to capture the effect of variable properties and thermal stratification. All cases in the simulation exhibited higher wall temperatures and lower convective coefficients than those determined through 1-D analytical equations. This implies that pressure and velocity safety factors must be implemented during system operation. Overall, the findings made in this investigation are thought to be of value to researchers and industrial practitioners when designing oxy-fuel direct power extraction systems operating at temperatures exceeding 3000 K. In addition to this, the implementation of the developed technology at pilot and commercial scales could result in a significant improvement in the efficiencies of heritage and next-generation power cycles.

03 NATURAL GAS↗

Exploring the Inner Acceleration Region of Solar Wind: A Study Based on Coronagraphic UV and Visible Light Data

This work combined coronagraphic visible light (VL) and UV data to provide with an unprecedented view of the inner corona where the nascent solar wind is accelerated. The UV (H i Lyα) and VL (polarized brightness) images (reconstructed with SOHO/UVCS, LASCO, and Mauna Loa data) have been analyzed with the Doppler dimming technique to provide for the first time daily 2D images of the radial wind speed between 1 and 6 R {sub ⊙} over 1 month of observations. Results show that both polar and equatorial regions are characterized at the base of the corona by plasma outflows at speeds >100 km s{sup −1}. The plasma is then decelerated within ∼1.5 R {sub ⊙} at the poles and ∼2.0 R {sub ⊙} at the equator, where local minima of the expansion speeds are reached, and gently reaccelerated higher up, reaching speeds typical of fast and slow wind components. The mass flux is highly variable with latitude and time at the equator and more uniform and stable over the poles. The polar flow is asymmetric, with speeds above the south pole lower than those above the north pole. A correlation (anticorrelation) between the wind speed and its density is found below (above) ∼1.8 R {sub ⊙}. The 2D distribution of forces responsible for deceleration and reacceleration of solar wind is provided and interpreted in terms of Alfvén waves. These results provide a possible connection between small-scale outflows reported with other instruments at the base of the corona and bulk wind flows measured higher up.

79 ASTRONOMY AND ASTROPHYSICS↗

High resolution neutron imaging of water in the polymer electrolyte membrane

To achieve a deeper understanding of water transport and performance issues associated with water management, we have conducted in situ water examinations to help understand the effects of components and operation. High Frequency Resistance (HFR), AC Impedance and neutron radiography were used to measure water content in operating fuel cells under various operating conditions. Variables examined include: sub-freezing conditions, inlet relative humidities, cell temperature, current density and response transients, different flow field orientations and different component materials (membranes, GDLs and MEAs). Quantification of the water within the membrane was made by neutron radiography after equilibration to different humidified gases, during fuel cell operation and in hydrogen pump mode. The water content was evaluated in bare Nafion{reg_sign} membranes as well as in MEAs operated in both fuel cell and H{sub 2} pump mode. These in situ imaging results allow measurement of the water content and gradients in the PEFC membrane and relate the membrane water transport characteristics to the fuel cell operation and performance under disparate materials and operational combinations. Flow geometry makes a large impact on MEA water content. Higher membrane water with counter flow was measured compared with co-flow for sub-saturated inlet RH's. This correlates to lower HFR and higher performance compared with co-flow. Higher anode stoichiometry helps remove water which accumulates in the anode channels and GDL material. Cell orientation was measured to affect both the water content and cell performance. While membrane water content was measured to be similar regardless of orientation, cells with the cathode on top show flooding and loss of performance compared with similarly operated cells with the anode on top. Transient fuel cell current measurements show a large degree of hysteresis in terms of membrane hydration as measured by HFR. Current step transients from 0.01 A cm{sup -2} to 0.68 A cm{sup -2} consistently show PEM wetting occurring within 5 to 20 sec. Whereas the PEM drying response to the reverse step transient of 0.68 A cm{sup -2} to 0.01 A cm{sup -2}, takes several minutes. The observed faster wetting response is due to reaction water being produced in the cathode and back diffusing into the membrane. The slower PEM drying is due to the water slowly being removed out of the wetted GDLs. This rate of removal of water and hence the PEM hydration level was found to be influenced strongly by the PTFE loadings in the GDL substrate and Microporous layer (MPL). The drying of the membrane is influenced by both the anode and cathode GDL PTFE loadings. Lower PTFE loading in the anode GDL leads to better membrane hydration probably due to the easier incorporation of water from the anode GDL into the membrane. Similarly a lower PTFE loading in the cathode GDL also results in better membrane hydration probably due to the better water retention properties (less hydrophobic) of this GDL. Fuel cells operated isothermal at sub-freezing temperatures show gradual cell performance decay over time and eventually drops to zero. AC impedance analysis indicates that losses are initially due to increasing charge transfer resistance. After time, the rate of decay accelerates rapidly due to mass transport limitations. High frequency resistance also increases over time and is a function of the initial membrane water content. These results indicate that catalyst layer ice formation is influenced strongly by the MEA and is responsible for the long-term degradation of fuel cells operated at sub-freezing temperatures. Water distribution measurements indicate that ice may be fonning mainly in the GDLs at -10 C but are concentrated in the catalyst layer at -20 C.

08 HYDROGEN↗

Progress on the development of new correlations under the framework of the IAEA Coordinated Research Programme on heat transfer in SCWR's

This paper begins with an introduction designed to provide researchers who are new to field of heat transfer to fluids at supercritical pressure with a brief picture of early developments, and to set the scene for the review of work on the development of new correlations for such fluids under the framework of the IAEA CRP. These are needed because of the active consideration now being given to water-cooled nuclear reactors operating at pressures above the critical value. Work on the development of a trans-critical look-up table aimed at covering the region near the critical point is outlined. A very large heat transfer databank has been compiled and subjected to a thorough screening process. It covers a wide range of conditions and has been used for the assessment of the performance of a number of empirical equations. A detailed error analysis was carried out for the most promising ones and an examination of parametric trends was made. A new correlation is described which has been specifically designed to combine simplicity of structure, explicit connection with physically-based phenomena whilst being able to cover both normal and deteriorated heat transfer conditions. It avoids direct dependence of heat transfer coefficient on wall temperature. The performance of this correlation was evaluated using the data set of Herkenrath et al for water at supercritical pressure. Results from a recent experimental study of heat transfer to carbon dioxide at supercritical pressure under conditions of mixed convection have been used to develop a set of equations to describe the general behaviour observed. Comparisons are made between the performance of a number of equations and the data from the carbon dioxide experiments and also some for water. Finally, the development is outlined of physically-based, semi-empirical models aimed at extending an empirical equation for variable property forced convection heat transfer to fluids at supercritical pressure to account for influences of buoyancy and flow acceleration. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Retrofittable Thermal Switches for Dynamic Building Envelopes Integrated with Thermal Energy Storage: Preprint

Buildings in the United States consume about 40 quadrillion BTU of primary energy annually, which accounts for the nation's 40% of total energy use, 75% of all electricity use, and 35% of the net carbon emissions. Deploying thermal energy storage in the form of phase change material (PCM) in building envelopes is an effective method to reduce space heating/cooling loads, provide load shedding, and shift demand to periods of lower energy cost. However, the full potential of PCM-integrated envelopes can only be realized if the PCM undergoes complete phase change using free ambient heating/cooling, and the stored energy is effectively transferred between the exterior and the interior environments. Conventional thermal insulation (with a fixed thermal resistance) limits PCM utilization, particularly with the increasing emphasis on higher R-value in building envelopes, which negatively affects the energy-saving potential of a PCM-integrated envelope. In contrast, dynamic building envelopes integrated with PCMs provide the option of varying the thermal resistance based on the indoor and outdoor conditions, thereby enhancing utilization of free ambient cooling and heating to charge/discharge the PCM thermal storage, reducing the buildings' heating and cooling load, and shifting the peak energy demand. In this study, we demonstrate innovative retrofittable thermal switches in the form of the insertable plugs inside an insulation to provide variable thermal resistance depending on the operating temperature and direction of temperature gradient, thus allowing preferential directional heat flow. Notably, they are passive in nature, requiring no external power, and work solely based on the ambient temperature.

buildings↗

Quantification of process variables for carbothermic synthesis of UC 1-x N x fuel microspheres

This report details the continued investigation of process variables involved in converting sol-gel-derived, urania-carbon microspheres to ~820-μm-dia. UC 1-x N x fuel kernels in flow-through, vertical Mo and W crucibles at temperatures up to 2123 K. Experiments included calcining of air-dried UO 3 -H 2 O-C microspheres in Ar and H 2 -containing gases, conversion of the resulting UO 2 -C kernels to dense UO2:2UC in the same gases and vacuum, and its conversion in N 2 to UC 1-x N x (x = ~0.85). The thermodynamics of the relevant reactions were applied extensively to interpret and control the process variables. Producing the precursor UO 2 :2UC kernel of ~96% theoretical density was required, but its subsequent conversion to UC 1-x N x at 2123 K was not accompanied by sintering and resulted in ~83-86% of theoretical density. Increasing the UC 1-x N x kernel nitride component to ~0.98 in flowing N 2 -H 2 mixtures to evolve HCN was shown to be quantitatively consistent with present and past experiments and the only useful application of H 2 in the entire process.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

On specification of initial conditions in turbulence models

Recent research has shown that initial conditions have a significant influence on the evolution of a flow towards turbulence. This important finding offers a unique opportunity for turbulence control, but also raises the question of how to properly specify initial conditions in turbulence models. We study this problem in the context of the Rayleigh-Taylor instability. The Rayleigh-Taylor instability is an interfacial fluid instability that leads to turbulence and turbulent mixing. It occurs when a light fluid is accelerated in to a heavy fluid because of misalignment between density and pressure gradients. The Rayleigh-Taylor instability plays a key role in a wide variety of natural and man-made flows ranging from supernovae to the implosion phase of Inertial Confinement Fusion (ICF). Our approach consists of providing the turbulence models with a predicted profile of its key variables at the appropriate time in accordance to the initial conditions of the problem.

42 ENGINEERING↗

Quantifying electron transport in aggregated colloidal suspensions in the strong flow regime

Electron transport in complex fluids, biology, and soft matter is a valuable characteristic in processes ranging from redox reactions to electrochemical energy storage. These processes often employ conductor–insulator composites in which electron transport properties are fundamentally linked to the microstructure and dynamics of the conductive phase. While microstructure and dynamics are well recognized as key determinants of the electrical properties, a unified description of their effect has yet to be determined, especially under flowing conditions. In this work, the conductivity and shear viscosity are measured for conductive colloidal suspensions to build a unified description by exploiting both recent quantification of the effect of flow-induced dynamics on electron transport and well-established relationships between electrical properties, microstructure, and flow. These model suspensions consist of conductive carbon black (CB) particles dispersed in fluids of varying viscosities and dielectric constants. In a stable, well-characterized shear rate regime where all suspensions undergo self-similar agglomerate breakup, competing relationships between conductivity and shear rate were observed. To account for the role of variable agglomerate size, equivalent microstructural states were identified using a dimensionless fluid Mason number, Mn f , which allowed for isolation of the role of dynamics on the flow-induced electron transport rate. At equivalent microstructural states, shear-enhanced particle–particle collisions are found to dominate the electron transport rate. This work rationalizes seemingly contradictory experimental observations in literature concerning the shear-dependent electrical properties of CB suspensions and can be extended to other flowing composite systems.

Science & Technology - Other Topics↗

A general peridynamics model for multiphase transport of non-Newtonian compressible fluids in porous media

Herein a general state-based peridynamics model is developed to simulate transport of fluids in an arbitrary heterogeneous porous medium. The generality encompasses modeling of multiphase, multi-component flow of non-Newtonian and compressible fluids, which is often encountered in but not limited to subsurface reservoirs. Peridynamic model is especially useful for solving non-local problems, such as crack propagation, since it does not assume spatial continuity of field variables. Thus, the formulation presented here, combined with peridynamics-based damage model, can be used to simulate hydraulic fracturing with complex fluids. To demonstrate its capability to simulate multi-phase flow in porous media, the derived model is verified against the analytical Buckley-Leverett solution for immiscible Newtonian two-phase flow. Further, the non-Newtonian two-phase fluid flow in porous media is verified by simulating the polymer flood process involving immiscible displacement of a Newtonian fluid by a non-Newtonian fluid against a generalized solution obtained by Wu et al. The non-local solutions are shown to be consistent with the corresponding local solutions in limiting cases. Moreover, mass conservation of all the phases is satisfied, irrespective of discretization and extent of non-locality.

42 ENGINEERING↗

Chapter 14: Machine Learning of Combustion LES Models from Reacting Direct Numerical Simulation

In this chapter we demonstrate how supervised deep learning techniques can be used to construct models for the filtered progress variable source term necessary for large eddy simulation (LES). The source data for the model is a direct numerical simulation (DNS) of a reacting flow in a low swirl burner configuration. Filtered quantities taken from the DNS data are used to train a deep neural network (DNN)-based model. An efficient data sampling strategy was devised to ensure that a uniform representation of all the states observed in the filtered DNS data are equally present in the training dataset. A-priori testing of the DNN-based model highlights the representative power of DNN to accurately reproduce the filtered reaction progress variable source term over a range of scales and various flame regimes as seen in an industrial burner.

combustion LES models↗

Influence of Agricultural Managed Aquifer Recharge (AgMAR) and Stratigraphic Heterogeneities on Nitrate Reduction in the Deep Subsurface

Agricultural managed aquifer recharge (AgMAR) is a strategy whereby surface water is used to intentionally flood croplands to recharge underlying aquifers. However, nitrate (NO 3 - ) contamination in agriculturally intensive regions poses a threat to groundwater resources under AgMAR. We use a reactive transport model to understand the effects of AgMAR management strategies (i.e., by varying the frequency, duration between flooding events, and amount of water) on NO 3 - leaching to groundwater under different stratigraphic configurations and antecedent moisture conditions. We examine the potential of denitrification and nitrogen retention in deep vadose zone sediments (~15 m) using variable AgMAR application rates on two-dimensional representations of differently textured soils, soils with discontinuous bands/channels, and with preferential flow paths characteristic of agricultural fields. Simulations indicate finer textured sediments, alone or embedded within/adjacent to high flow regions, are important reducing zones providing conditions needed for denitrification. Simulation results suggest that applying water all-at-once rather than in increments transports higher concentrations of NO 3 - deeper into the profile, which may exacerbate groundwater quality. This transport into deeper depths can be aggravated by wetter antecedent soil moisture conditions. However, applying water all-at-once also increases denitrification within the vadose zone by promoting anoxic conditions. We conclude that AgMAR can be designed to enhance denitrification in the subsurface and reduce NO 3 - leaching to groundwater, while specifically accounting for lithologic heterogeneity, antecedent soil moisture conditions, and depth to the water table. Our findings are potentially relevant to other systems that experience flooding inundation such as floodplains and dedicated recharge basins.

54 ENVIRONMENTAL SCIENCES↗