Search NASA⌕ Search

SEARCH · Search NASA

Results for “wind program”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,171 records · Page 65

AGC 2 Irradiation Creep Strain Data Analysis

The Advanced Reactor Technologies Graphite Research and Development Program is conducting an extensive graphite irradiation experiment to provide data for licensing of a high temperature reactor (HTR) design. In past applications, graphite has been used effectively as a structural and moderator material in both research and commercial high temperature gas cooled reactor designs. Nuclear graphite H-451, used previously in the United States for nuclear reactor graphite components, is no longer available. New nuclear graphite grades have been developed and are considered suitable candidates for new HTR reactor designs. To support the design and licensing of HTR core components within a commercial reactor, a complete properties database must be developed for these current grades of graphite. Quantitative data on in service material performance are required for the physical, mechanical, and thermal properties of each graphite grade, with a specific emphasis on data accounting for the life limiting effects of irradiation creep on key physical properties of the HTR candidate graphite grades. Further details on the research and development activities and associated rationale required to qualify nuclear grade graphite for use within the HTR are documented in the graphite technology research and development plan.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

AGC-3 Irradiation Creep Strain Data Analysis

The Advanced Reactor Technologies Graphite Research and Development Program is conducting an extensive graphite irradiation experiment to provide data for licensing of a high temperature reactor (HTR) design. In past applications, graphite has been used effectively as a structural and moderator material in both research and commercial high temperature gas cooled reactor designs. , Nuclear graphite H 451, used previously in the United States for nuclear reactor graphite components, is no longer available. New nuclear graphite grades have been developed and are considered suitable candidates for new HTR reactor designs. To support the design and licensing of HTR core components within a commercial reactor, a complete irradiated properties database must be developed for these current grades of graphite. Quantitative data on in service material performance are required for the physical, mechanical, and thermal properties of each graphite grade, with a specific emphasis on data accounting for the life limiting effects of irradiation creep on key physical properties of the HTR candidate graphite grades. Further details on the research and development activities and associated rationale required to qualify nuclear grade graphite for use within the HTR are documented in the graphite technology research and development plan.

42 ENGINEERING↗

Grid-Supportive Loads - A New Approach to Increasing Renewable Energy in Power Systems

This paper demonstrates the potential of inverter-based loads to support grid reliability during power system transients thereby enabling reliable integration of renewable energy in power systems. Such loads are referred to in this paper as grid-supportive loads (GSLs). A new GSL model is developed that simulates the transient response capabilities that can be programmed in electronic loads. The model’s design enables it to be easily integrated in widely used commercial power system transient analysis software. Theoretical expressions are derived that explain the workings of the GSL model. The performance, numerical stability, and impact of the GSL model is validated on 9-bus and 2000-bus synthetic power system models using generator tripping and bus fault disturbances. Results on the 2000 bus system show that in the absence of frequency support from wind/solar generation resources, just 20% of loads with grid-supportive capabilities can improve frequency response by up to 2000 MW/0.1 Hz and reduce deviation in frequency at nadir by up to 60% compared to the situation when GSLs are absent. Power system reliability also improves under fault events. Here, it is further shown that GSLs can aid in integrating more renewable generation without degrading the overall transient response of the power system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Renewable Firming EnergyFarm Final Report

The American Recovery and Reinvestment Act (ARRA) of 2009 (Recovery Act) provided the U.S. Department of Energy (DOE) with funds to modernize the electric power grid. One program under this initiative is the Smart Grid Demonstration program (SGDP). The SGDP mandate is to demonstrate how a suite of existing and emerging smart grid technologies can be innovatively applied and integrated to prove technical, operational, and business-model feasibility. Primus Power is a provider of low cost, long life and long duration energy storage systems. The Company’s flow batteries are shipping to US and international microgrid, utility, military, commercial and industrial customers. Primus Power’s EnergyPod® is a modular battery system for grid scale applications available in configurations ranging from 25 kW to more than 25 MW. The EnergyPod provides nameplate power for 5 hours. This long duration unlocks economic benefits on both sides of the electric meter. It allows commercial and industrial customers to shift low cost electricity purchased at night to offset afternoon electrical peaks to reduce utility demand charges. It also allows utilities to economically reduce power peaks and defer costly upgrades to distribution infrastructure. An EnergyPod contains one or more EnergyCells-a highly engineered flow battery core made from low cost, readily available materials. An EnergyCell includes a membrane-free stack of titanium electrodes located above a novel liquid electrolyte management system. This patented design enables reliable, low maintenance operation for decades. It is safe and robust, featuring non-flammable aqueous electrolyte, sophisticated fault detection and built-in secondary containment. Unlike Li Ion batteries, the EnergyCell is not susceptible to thermal runaway. This cooperative agreement project was started in Feb 2010. The objectives of the project are: 1. Trigger rapid adoption of grid storage systems in the US by demonstrating a low cost, robust and flexible EnergyFarm®. 2. Accelerate adoption of renewable energy and enhance grid stability by firming the output of wind & solar farms. 3. Demonstrate improved grid asset utilization by storing energy during off-peak periods for dispatch during local load peaks. 4. Establish an advanced battery manufacturing industry in the U.S. 5. Reduce CO2 emissions from utilities. This report summarizes the key milestones, data, results and lessons learned from the project. The desired goals and benefits of the cooperative agreement with the DOE have all been achieved. The project has contributed to reducing power costs, accelerating adoption of renewable energy resources, reducing greenhouse gas emissions and establishing advanced battery manufacturing in the U.S. The Recovery Act funds provided thru the DOE have been leveraged multiple times by additional private equity investment. Primus Power continues to ship low cost, long life and long duration EnergyPod® flow battery systems to utilities, commercial/industrial, microgrid and data center customers. After the conclusion of this project, Primus Power has modified the EnergyPod® design to optimize around energy performance. Primus Power has moved to a prefabricated enclosure instead of multiple EnergyCells in a container. This lowers capital and maintenance costs and can optimize site design. Utilities are starting to adopt energy storage for a variety of functions. The market will grow as the technology is proven and profitable applications expand.

25 ENERGY STORAGE↗

A Novel Process for Carbon Dioxide Conversion to Fuel

In this project, TDA developed a new mixed metal oxide-based sorbent that converts CO2 (captured from coal fired power plants) to CO, which can then be combined with renewable H2 generated by water electrolysis or H2 from steam methane reforming to produce different liquid fuels. TDA’s absorbent-based CO2 conversion process uses a redox process, which splits the catalytic reforming of methane with CO2 reaction into two stages: CO2 reduction to CO and CH4 reforming into H2 and CO which eliminates the equilibrium limitations. The CO produced in the two-stage reactor system can then be further reacted with renewable H2 to produce methanol, naphtha, diesel, or gasoline. We worked with the Advanced Power & Energy Program (APEP) of University of California, Irvine (UCI) to design and develop the liquid fuel synthesis process that is built around this new material. We demonstrated the techno-economic viability of the new sorbent based redox process to convert CO2 into synthesis gas by demonstrating continuous carbon dioxide reduction in a prototype test system for over 585 hours while converting up to 10 kg CO2/day. With the successful completion of the R&D effort, the technology is now ready for a larger pilot-scale demonstration and the technology readiness has been raised from TRL 3 to TRL 5. In collaboration with UCI, we completed a high-fidelity process design and economic analysis. The required sale price (RSP) for gasoline (Case 1 NG-MTG) is $4.91/gal and naphtha and diesel (Case 2 NG-FT) are $4.23/gal and $6.07/gal, respectively, on a 2011 dollar basis. To put these costs in perspective, the California prices in current dollars (with its strict specifications) for regular grade gasoline from last year to current year have varied from a low of $3.10/gal in January 2021 to a high of $5.76/gal in March 2022, while prices for diesel from last year to current year have varied from a low of $3.40/gal in January 2021 to a high of $6.41/gal in May 2022 according to the U.S. Energy Information Agency data. It should be noted that the gasoline and diesel produced by these designs of Case 1 and Case 2 would be of very high quality and both nitrogen and sulfur free. These RSPs are based on a cost of imported electricity of $64/MWh based on the low-end current wind generated electricity cost (Genevieve 2011). This cost is by far the largest component of the variable costs used in computing the RSPs. A sensitivity analysis of these RSPs to the cost of imported electricity shows that the cost of the imported electricity has a significant effect on the RSPs. The life cycle analysis (LCA) shows that the total cradle-to-gate CO2 emissions for both liquid fuels (diesel and gasoline) were negative, indicating that overall more CO2 is consumed than released during production of the fuel from CO2 feed stack for both cases (-296 kgCO2 per MT gasoline for Case 1 and -705 kgCO2 per MT diesel for Case 2). On a cradle-to-grave comparison, the use of diesel produced using TDA’s process (2,457 kgCO2 per MT diesel) would release 37.6% less CO2 compared to petroleum based diesel (3,937 kgCO2 per MT diesel) while the use of gasoline produced using TDA’s process (2,792 kgCO2 per MT gasoline) would release 29.3% less CO2 compared to petroleum based gasoline (3,946 kgCO2 per MT gasoline). With the successful completion of the R&D effort, the technology is now ready for a bench-scale demonstration and the technology readiness has been raised from TRL 3 (Analytical and experimental critical function and/or characteristic proof of concept) to TRL 5 (Laboratory scale similar system validation in relevant environment).

20 FOSSIL-FUELED POWER PLANTS↗

Collaborative Research: Advancing Arctic Climate Projection Capability at Seasonal to Decadal Scales (Final Technical Report)

The Regional Arctic System Model (RASM) at process resolving configurations has been used to (i) advance understanding of physical processes and feedbacks involved in Arctic amplification and (ii) understand and potentially reduce uncertainty in prediction of arctic climate change at seasonal to decadal scales. RASM consists the atmosphere (Weather and Research Forecasting model, WRF), ocean (Parallel Ocean Program, POP), sea ice (CICE), land hydrology (Variable Infiltration Capacity model, VIC), river routing scheme (RVIC), marine biogeochemistry components and the coupling framework (CPL7). Its domain is pan-Arctic, with the atmosphere and land components configured on a 50-km or 25-km grid and four configurations of the ocean and sea ice components: 1/12°(~9.3km) or 1/48°(~2.4km) and 45 or 60 vertical layers. These RASM configurations have been motivated by the emerging exascale capability for high performance computing to improve model fidelity. The dynamical downscaling of reanalysis allows comparison of RASM results with observations in place and time to: (i) advance system level understanding of physical processes and coupling involved in an event, (ii) optimize model parameter space, (iii) diagnose and reduce model biases and (iv) produce realistic and consistent across all the components initial conditions for predictions and predictability studies, which are all unique capabilities not available in global Earth System Models (ESMs). An evaluation of RASM 1.0 (Cassano et al. 2017) revealed that it had a cold bias over the oceans and a warm bias over land areas due largely to cloud and radiation biases in the model, with too little cloud cover simulated over land and too much cloud cover simulated over sub-polar oceans. This study has motivated an upgrade to WRF version 3.7.1 in RASM and allowed for the inclusion of the radiative impact of convective clouds. A variety of atmospheric physics parameterizations were evaluated against observations (e.g. data from the Arctic Clouds in Summer Experiment (ACSE); Sedlar et al. 2020) to identify an optimal suite of WRF physics options in RASM. The RASM with the optimized WRF physics were used to study the impact of strong mesoscale winds over the ocean around the southern tip of Greenland (DuVivier and Cassano 2016) and their impact on oceanic convection (DuVivier et al. 2017a). Data from the PolarWinds field campaign were used to evaluate WRF boundary layer physics and resolution impacts on the simulation of a Greenland barrier wind event (DuVivier et al. 2017b). The RVIC streamflow routing model has been implemented in RASM to realistically represent high-resolution streamflow processes (Hamman et al. 2017) and to couple the land buoyancy fluxes to the ocean. The RASM-RVIC high-resolution data set of all coastal freshwater fluxes for the Arctic drainage basin and surrounding areas for 1979-2014 was published as a separate product (https://doi.org/10.5281/zenodo.293037). The fidelity of atmospheric momentum transfer to and the response of polar marine Ekman layer in RASM and Community Earth System Model (CESM) was investigated by Roberts et al. (2015). The increased frequency of oceanic flux exchange in CESM, following the RASM guidance, caused a considerable increase in the median inertial ice speed across the Southern Ocean and parts of the Arctic. A comprehensive evaluation of the RASM1.0 atmosphere-ocean-sea ice-land interface was completed by Brunke et al. (2018). RASM was also demonstrated for its capability to simulate extreme events in agreement with observations in space and time (Lee et al. submitted). In particular, the development of three open water events, known as polynyas, have been simulated north of Greenland in February of 2011, 2017 and 2018, in agreement with satellite observations for the past four decades. The optimized RASM sea ice results have been favorably evaluated against satellite observations and a subset of eleven CMIP6 models (Watts et al. submitted). In a complementary project, Jin et al. (2018) have shown that RASM with higher-resolution and new sea-ice processes contributed to lower model errors in sea-ice conditions, concentrations of nutrients and ice algae, in comparison to results from the coarse-resolution (1°) CESM. In two other complementary studies, RASM results were used (i) to explain areas of concentrated use by bowhead whales, the seasonal progression in the use, and the physical environment within those areas (Citta et al. 2015) and (ii) for a synthesis of fall bowhead whales distribution and migration in the Bering-Chukchi-Beaufort (BCB) Sea to investigate whale movements and feeding to the local ocean hydrography and currents (Citta et al. 2018). However, the multi-decadal output from the CESM Large Ensemble yielded unrealistic forcing. Instead, the shorter NCEP CFSv2 9-month forecasts were successfully tested and afforded an increased ensemble size (~30) to demonstrate gains of dynamical downscaling at sub-seasonal to intra-annual time scales. The improved model physics and coupling among RASM model components have yielded more realistic representation of the sea ice cover and consistent across all model components initial conditions. Consequently, RASM demonstrates significant gains compared to simulation of sea ice in the NCEP reanalysis. In addition, RASM 6-month ensemble forecasts yield very realistic sea ice distribution, which demonstrates both significant gains of dynamical downscaling and the continued impact of the initial conditions on forecasts out to 6 months (https://nps.edu/web/rasm/predictions). A follow up study using RASM for dynamical downscaling of the more realistic CESM initialized Decadal Prediction Large Ensemble output is currently ongoing as part of the DOE RGMA HiLAT-RASM project.

54 ENVIRONMENTAL SCIENCES↗

OPTOM: Optimization of Parabolic Trough - Operations & Maintenance

The US Department of Energy’s SunShot goals look to reduce the cost of Concentrating Solar Power (CSP) technology to 5¢/kWh for baseload plants. This is about a 50% reduction from current costs. To achieve this cost target, a significant reduction in operation and maintenance (O&M) costs of 40 to 50% is likely needed. Advances are needed in the O&M practices of CSP plants if the technology is to achieve the SunShot cost goals. Digitization of plant performance and O&M data has become a new best practice in the world of renewable energy asset management. Owners and operators of large photovoltaic and wind power plants are working to digitize performance and O&M data at their existing assets, to improve their management of the facilities, to increase performance, reduce O&M costs, and lower the overall life cycle cost of ownership. CSP power plants are behind the curve of other technologies on the digitization of plant information to aid in the plant asset management. This project directly addresses the objective of digitizing the O&M data of the solar field, focusing on three areas: 1) creating a framework for sharing data and information, 2) creating a system for monitoring and managing the maintenance of the solar field collectors, and 3) developing analytic tools to identify issues in the solar field. According to the NREL CSP Best Practices Study, the current practice at many CSP plants is to rely on paper lists, spreadsheets, and email for monitoring and managing problems and maintenance in the solar field. The key element to digitize solar field O&M is the creation of a centralized data archive that all users and systems can interface with. This project developed a centralized relational database framework that allows users and applications to access and share data. Conventional power plants utilize Computerized Maintenance Management Systems (CMMSs) to track the corrective, preventive (scheduled), and predictive maintenance of equipment and subsystems in the power plant. CSP plants use these systems in the power block, but while these systems specialize at tracking maintenance on up to thousands of pieces of equipment, they are not well suited for tracking the tens or hundreds of thousands of components in large commercial CSP or photovoltaic solar fields. In this project we developed a new software application referred to as FieldStatus (TM). This is a specialized database program that is used to track the status of each collector and its components. This application is designed to complement the existing CMMS to enable improved tracking and management of maintenance activities in the solar field. One of the major maintenance tasks for solar fields is maintaining the cleanliness of the mirrors. Although seemingly a relatively straight forward task, it has often proven challenging to maintain high levels of cleanliness in an efficient and cost-effective manner. This project developed new tools and metrics for monitoring and optimizing solar field cleaning resources and overall solar field cleanliness.

14 SOLAR ENERGY↗

Elk Valley Rancheria Energy Efficiency and Alternatives Analysis

The Elk Valley Rancheria, California ('Tribe') is a federally recognized Indian tribe located in Del Norte County, California, in the northwestern corner of California. The Tribe, its members and Tribal enterprises are challenged by increasing energy costs and undeveloped local energy resources. The Tribe currently lacks an energy program. The Tribal government lacked sufficient information to make informed decisions about potential renewable energy resources, energy alternatives and other energy management issues. To meet this challenge efficiently, the Tribe contracted with Frank Zaino and Associates, Inc. to help become more energy self-sufficient, by reducing their energy costs and promoting energy alternatives that stimulate economic development. Frank Zaino & Associates, Inc. provided a high level economic screening analysis based on anticipated electric and natural gas rates. This was in an effort to determine which alternative energy system will performed at a higher level so the Tribe could reduce their energy model by 30% from alternative fuel sources. The feasibility study will identify suitable energy alternatives and conservation methods that will benefit the Tribe and tribal community through important reductions in cost. The lessons learned from these conservation efforts will yield knowledge that will serve a wider goal of executing energy efficiency measures and practices in Tribal residences and business facilities. Pacific Power is the provider of electrical power to the four properties under review at $ 0.08 per Kilowatt-hour (KWH). This is a very low energy cost compared to alternative energy sources. The Tribe used baseline audits to assess current and historic energy usage at four Rancheria owned facilities. Past electric and gas billing statements were retained for review for the four buildings that will be audited. A comparative assessment of the various energy usages will determine the demand, forecast future need and identify the differences in energy costs, narrowing the focus of the work and defining its scope. The Tribe's peak demand periods will help determine the scope of need for alternative energy sources. The Tribe's Energy Efficiency and Alternatives Analysis report included several system investigations which include fuel cells, wind turbines, solar panels, hydro electric, ground source heat pumps, bio mass, cogeneration & energy conservation and implementation for the existing properties. The energy analysis included site visits to collect and analyze historical energy usage and cost. The analysis also included the study of the building systems for the Elk Valley Casino, Elk Valley Rancheria administration complex, United Indian Health Service/Small Community Center complex and the Tribal Gaming Commission Offices. The analysis involved identifying modifications, performing an engineering economic analysis, preparation of a rank ordered list of modifications and preparation of a report to provide recommendations and actions for the Tribe to implement.

03 NATURAL GAS↗

AGC-2 Specimen Post Irradiation Data Package Report

This report documents results of the post-irradiation examination material property testing of the creep, control, and piggyback specimens from the irradiation creep capsule Advanced Graphite Creep (AGC)-2 are reported. This is the second of a series of six irradiation test trains planned as part of the AGC experiment to fully characterize the neutron irradiation effects and radiation creep behavior of current nuclear graphite grades. The AGC-2 capsule was irradiated in the Idaho National Laboratory Advanced Test Reactor at a nominal temperature of 600°C and to a peak dose of 5 dpa (displacements per atom). One half of the creep specimens were subjected to mechanical stresses (an applied stress of either 13.8, 17.2, or 20.7 MPa) to induce irradiation creep. All post-irradiation testing and measurement results are reported with the exception of the irradiation mechanical strength testing, which is the last destructive testing stage of the irradiation testing program. Material property tests were conducted on specimens from 15 nuclear graphite grades using a similar loading configuration as the first AGC capsule (AGC-1) to provide easy comparison between the two capsules. However, AGC-2 contained an increased number of specimens (i.e., 487 total specimens irradiated) and replaced specimens of the minor grade 2020 with the newer grade 2114. The data reported include specimen dimensions for both stressed and unstressed specimens to establish the irradiation creep rates, mass and volume data necessary to derive density, elastic constants (Young’s modulus, shear modulus, and Poisson’s ratio) from ultrasonic time of flight velocity measurements, Young’s modulus from the fundamental frequency of vibration, electrical resistivity, and thermal diffusivity and thermal expansion data from 100–500°C. No data outliers were determined after all measurements were completed. A brief statistical analysis was performed on the irradiated data and a limited comparison between pre- and post-irradiation properties is presented. A more complete evaluation of trends in the material property changes, as well as irradiation-induced creep due to irradiation, temperature, and applied load on specimens will be discussed in later AGC-2 post-irradiation examination analysis reports.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

AGC-2 Specimen Post Irradiation Data Package Report

This report documents results of the post-irradiation examination material property testing of the creep, control, and piggyback specimens from the irradiation creep capsule Advanced Graphite Creep (AGC)-2 are reported. This is the second of a series of six irradiation test trains planned as part of the AGC experiment to fully characterize the neutron irradiation effects and radiation creep behavior of current nuclear graphite grades. The AGC-2 capsule was irradiated in the Idaho National Laboratory Advanced Test Reactor at a nominal temperature of 600°C and to a peak dose of 5 dpa (displacements per atom). One-half of the creep specimens were subjected to mechanical stresses (an applied stress of either 13.8, 17.2, or 20.7 MPa) to induce irradiation creep. All post-irradiation testing and measurement results are reported with the exception of the irradiation mechanical strength testing, which is the last destructive testing stage of the irradiation testing program. Material property tests were conducted on specimens from 15 nuclear graphite grades using a similar loading configuration as the first AGC capsule (AGC-1) to provide easy comparison between the two capsules. However, AGC-2 contained an increased number of specimens (i.e., 487 total specimens irradiated) and replaced specimens of the minor grade 2020 with the newer grade 2114. The data reported include specimen dimensions for both stressed and unstressed specimens to establish the irradiation creep rates, mass and volume data necessary to derive density, elastic constants (Young’s modulus, shear modulus, and Poisson’s ratio) from ultrasonic time-of-flight velocity measurements, Young’s modulus from the fundamental frequency of vibration, electrical resistivity, and thermal diffusivity and thermal expansion data from 100–500°C. No data outliers were determined after all measurements were completed. A brief statistical analysis was performed on the irradiated data and a limited comparison between pre- and post-irradiation properties is presented. A more complete evaluation of trends in the material property changes, as well as irradiation-induced creep due to irradiation, temperature, and applied load on specimens will be discussed in later AGC-2 post-irradiation examination analysis reports.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Northwest Colorado Local Energy Analysis: October 2025 Results

The U.S. Department of Energy's (DOE) Communities Local Energy Action Program (Communities LEAP) provided customized technical assistance to the Northwest Colorado region to assist in developing strategies that facilitate long-term economic benefits through locally driven energy planning and development. The region sought technical assistance to model alternatives energy projects in response to the expected retirement of coal-fired powers plant and associated coal mines by 2030. Northwest Colorado faces a potential economic gap due to the loss of tax revenue, labor income, and jobs within the region due to the impending closure of the Craig and Hayden Power Stations and related mining operations at Trapper and Colowyo mines.

08 HYDROGEN↗

Lac Courte Oreilles Energy Analysis Project

The Lac Courte Oreilles Tribe applied for first step funding in 2007 and was awarded in October of that year. We wanted to perform an audit to begin fulfilling two commitments we made to our membership and resolutions that we adopted. One was the Kyoto Protocol and reduce our carbon emissions by 25% and to produce 25% of our energy by sustainable means. To complete these goals we needed to begin with first assessing what our carbon emissions are and begin taking the steps to conserve on the energy we currently use. The First Step Grant gave us the opportunity to do this. Upon funding the Energy Project was formed under the umbrella of the LCO Public Works Department and Denise Johnson was hired as the coordinator. She quickly began fulfilling the objectives of the project. Denise began by contact the LCO College and hiring interns who were able to go to each Tribal entity and perform line logging to read and document the energy used for each electrical appliance. Data was also gathered for one full year from each entity for all their utility bills (gasoline, electric, natural gas, fuel oil, etc.). Relationships were formed with the Green Team and other Green Committees in the area that could assist us in this undertaking. The Energy Task Force was of great assistance as well recommending other committees and guidance to completing our project. The data was gathered, compiled and placed into spreadsheets that would be understandable for anyone who didn't have a background in Renewable Resources. While gathering the data Denise was also looking for ways to conserve energy usage, policies changes to implement and any possible viable renewable energy resources. Changes in the social behaviors of our members and employees will require further education by workshops, energy fairs, etc.. This will be looked into and done in coordination with our schools. The renewable resources seem most feasible are wind resources as well as Bio Mass both of which need further assessment and funding to do so will be sought. While we already are in ownership of a Hydro Dam it is currently not functioning to its full capacity we are seeking operation and maintenance firm proposals and funding sources. One of our biggest accomplishment this project gave us was our total Carbon Emissions 9989.45 tons, this will be the number that we will use to base our reductions from. It will help us achieve our goals we have set for ourselves in achieving the Kyoto Protocol and saving our Earth for our future generations. Another major accomplishment and lesson learned is we need to educate ourselves and our people on how to conserve energy to both impact the environment and our own budgets. The Lac Courte Oreilles (LCO) Energy Analysis Project will perform an energy audit to gather information on the Tribe's energy usage and determine the carbon emissions. By performing the audit we will be able to identify areas where conservation efforts are most viable and recommend policies that can be implemented. These steps will enable LCO to begin achieving the goals that have been set by the Tribal Governing Board and adopted through resolutions. The goals are to reduce emissions by 25% and to produce 25% of its energy using sustainable sources. The project objectives were very definitive to assist the Tribe in achieving its goals; reducing carbon emissions and obtaining a sustainable source of energy. The following were the outlined objectives: (1) Coordinate LCO's current and future conservation and renewable energy projects; (2) Establish working relationships with outside entities to share information and collaborate on future projects; (3) Complete energy audit and analyze LCO's energy load and carbon emissions; (4) Identify policy changes, education programs and conservation efforts which are appropriate for the LCO Reservation; and (5) Create a plan to identify the most cost effective renewable energy options for LCO.

02 PETROLEUM↗

Analysis of the Effects of a Flexible Ramping Ancillary Service Product on Power System Operations: Preprint

The recent increased interest in utilizing variable generation (VG) resources such as wind and solar in power systems has motivated investigations into new operating procedures. Although these resources provide desirable value to a system (e.g., no fuel costs or emissions), interconnecting them provides unique challenges. Their variable, non-controllable nature in particular requires significant attention, because it directly results in increased power system variability and uncertainty. One way to handle this is via new operating reserve schemes. Operating reserves provide upward and downward generation and ramping capacity to counteract uncertainty and variability prior to their realization. For instance, uncertainty and variability in real-time dispatch can be accounted for in the hour-ahead unit commitment. New operating reserve methodologies that specifically account for the increased variability and uncertainty caused by VG are currently being investigated and developed by academia and industry. This paper examines one method inspired by the new operating reserve product being proposed by the California Independent System Operator. The method is based on examining the potential ramping requirements at any given time and enforcing those requirements via a reserve demand curve in the market-clearing optimization as an additional ancillary service product.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Environmental monitoring data from the 2022-2023 field experiment at Game Ridge, Missoula County, Montana, USA

This dataset contains sensor data from programmed loggers as well as handheld moisture probes, including weather data, air and soil temperature, and soil volumetric water content. Data files and data dictionary(ies) are uploaded as .csv files. The Users Guide is a .pdf file. Location data can be found in the Google Earth file GameRidge_SitePlotCoordinates.kmz.kml included here. These datasets were collected for Plant Carbohydrate Depletion, Mycorrhizal Networks, and Vulnerability to Drought: An Experimental Test in the Field. This experiment examined the interdependency between plant hydraulics and carbohydrate availability and sought to develop ways to incorporate interactions with below ground symbiotic organisms to better model and quantify forest response to drought. This environmental data was collected to provide context for the fungal community data and Pinus ponderosa physiological data.

54 ENVIRONMENTAL SCIENCES↗

Are coupled renewable-battery power plants more valuable than independently sited installations?

Coupled renewable-battery powerplants differ from the traditional concept of independent siting of electricity resources within transmission networks. Prior research on the value proposition and cost savings from coupling did not consider the geographic constraint of co-location. This paper fills the gap by assessing how pricing volatility differences between nodes within electricity markets impact the system value of coupled renewable-battery projects as compared to independent VRE and battery installations. We use wholesale power market prices from 2012–2019 across the seven main U.S. independent system operators (ISOs) with a linear optimization program to compare the electricity market value of coupled projects to the value of the same underlying sub-components, deployed separately. We find that additional value from adding a 4-hour battery sized to 50% of renewable-plant nameplate capacity is $\$$10/MWh across ISOs on average. The highest boost occurs in California ($\$$15/MWh), where the value of adding storage to solar rises over time in tandem with increased solar penetration in the region. If renewables and batteries are deployed independently, we estimate that $\$$12.5/MWh of additional value could be achieved because of more flexibility on battery siting and operation. The $\$$12.5/MWh coupling penalty is reduced to $\$$1.6/MWh when considering alternative approaches to integrating battery storage. This result implies that renewable-battery power plants will play an increasing role in electricity systems if they can be built for $\$$2–$\$$13/MWh less than independent projects of comparable size. However, the wide regional variation in coupling penalties, along with the importance of conditions captured in our sensitivity cases, suggests the tradeoff between coupling penalties and savings will vary by situation. Therefore, roles exist for independent and coupled projects from a system optimization perspective.

14 SOLAR ENERGY↗

Measurement of advective soil gas flux: Results of field and laboratory experiments with CO2

We modified our multi-channel, steady-state flow-through (SSFT), soil-CO2 flux monitoring system to include an array of inexpensive pyroelectric non-dispersive infrared detectors for full-range (0-100%) coverage of CO2 concentrations without dilution, and a larger-diameter vent tube. We then conducted field testing of this system from late July through mid-September 2010 at the Zero Emissions Research and Technology (ZERT) project site located in Bozeman, MT, and subsequently, laboratory testing at the Pacific Northwest National Laboratory (PNNL) in Richland, WA using a flux bucket filled with dry sand. In the field, an array of twenty-five SSFT and three non-steady-state (NSS) flux chambers was installed in a 10x4 m area, the long boundary of which was directly above a shallow (2-m depth) horizontal injection well located 0.5 m below the water table. Two additional chambers (one SSFT and one NSS) were installed 10 m from the well for background measurements. Volumetric soil moisture sensors were installed at each SSFT chamber to measure mean levels in the top 0.15 m of soil. A total flux of 52 kg CO2 d-1 was injected into the well for 27 d and the efflux from the soil was monitored by the chambers before, during, and for 27 d after the injection. Overall, the results were consistent with those from previous years, showing a radial efflux pattern centered on a known “hot spot”, rapid responses to changes in injection rate and wind power, evidence for movement of the CO2 plume during the injection, and nominal flux levels from the SSFT chambers that were up to 6-fold higher than those measured by adjacent NSS chambers. Soil moisture levels varied during the experiment from moderate to near saturation with the highest levels occurring consistently at the hot spot. The effects of wind on measured flux were complex and decreased as soil moisture content increased. In the laboratory, flux bucket testing with the SSFT chamber showed large measured-flux enhancement due to the Venturi effect on the chamber vent, but an overall decrease in measured flux when wind also reached the sand surface. Flux-bucket tests at a high flux (comparable to that at the hot spot) also showed that the measured flux levels increase linearly with the chamber-flushing rate until the actual level is reached. At the SSFT chamber-flushing rate used in the field experiment the measured flux in the laboratory was only about a third of the actual flux. The ratio of measured to actual flux increased logarithmically as flux decreased, and reached parity at low levels typical of diffusive flux systems. Taken together, our results suggest that values for advective CO2 flux measured by SSFT and NSS chamber systems are likely to be significantly lower than the actual values due to back pressure developed in the chamber that diverts flux from entering the chamber. Chamber designs that counteract the back pressure and also avoid large Venturi effects associated with vent tubes, such as the SSFT with a narrow vent tube operated at a high chamber-flushing rate, are likely to yield flux measurements closer to the true values.

carbon dioxide↗

Accomplishments in Field Period Assembly for NCSX* This is how we did it

The National Compact Stellarator Experiment (NCSX) was a collaborative effort between ORNL and PPPL. PPPL provided the assembly techniques with guidance from ORNL to meet design criteria. The individual vacuum vessel segments, modular coils, trim coils, and toroidal field coils components were delivered to the Field Period Assembly (FPA) crew who then would complete the component assemblies and then assemble the final three field period assemblies, each consisting of two sets of three modular coils assembled over a 120o vacuum vessel segment with the trim coils and toroidal field coils providing the outer layer. The requirements for positioning the modular coils were found to be most demanding. The assembly tolerances required for accurate positioning of the field coil windings in order to generate sufficiently accurate magnetic fields strained state of the art techniques in metrology and alignment and required constant monitoring of assembly steps with laser trackers, measurement arms, and photogrammetry. The FPA activities were being performed concurrently while engineering challenges were being resolved. For example, it was determined that high friction electrically isolated shims were needed between the modular coil interface joints and low distortion welding was required in the nose region of those joints. This took months of analysis and development yet the assembly was not significantly impacted because other assembly tasks could be performed in parallel with ongoing assembly tasks as well as tasks such as advance tooling setup preparation for the eventual welding tasks. The crew technicians developed unique, accurate time saving techniques and tooling which provided significant cost and schedule savings. Project management displayed extraordinary foresight and every opportunity to gain advanced knowledge and develop techniques was taken advantage of. Despite many risk concerns, the cost and schedule performance index was maintained nearly 1.0 during the assembly phase until project cancellation. In this paper, the assembly logic, the engineering challenges, solutions to those challenges and some of the unique and clever assembly techniques, will be presented.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Multi-Fidelity Stochastic Economic Dispatch for Operating Low Carbon Power Grids

Grid operators can address the inherently stochastic nature of renewables by solving a two-stage stochastic programming model that minimizes the cost of dispatch decisions while accounting for the complex grid dynamics. It is common to use a sample average approximation to estimate the expectation of the second stage costs in this model. However, the large sample count needed for numerical accuracy makes effective modeling large-scale electric grids computationally intractable. We introduce a control variate multi-fidelity estimator for the second-stage recourse that enables high quality dispatch decisions in real-time with a reduced computational burden. We obtain a hierarchy of model fidelities by linearizing the AC power flow system representation to DC power flow, and by relaxing transmission and voltage network constraints. We evaluate the performance of our proposed method on a synthetic grid with 73 buses against a deterministic baseline with persistence forecast and a high-fidelity reference. Our analysis shows a computational speed-up of 7.62x with a minimal loss in accuracy. The multi-fidelity method is well suited to fidelity combinations that use a simplified network topology in their lower fidelity model and is an attractive option for applications where accurate grid modeling needed on a limited computational budget.

24 POWER TRANSMISSION AND DISTRIBUTION↗