Search NASA⌕ Search

SEARCH · Search NASA

Results for “Analysis software”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,189 records · Page 66

Application of a Rapid Design Tool to a 3D Woven Structural Joint

The optimization of composite structural joints is an iterative process and a multiscale problem. High fidelity finite element modeling of joints with 3D woven and laminated materials can become computationally expensive. The aim of this paper is to establish a reliable analysis process for the optimization of a composite Y-joint (curved Pi-joint), to be used in an aircraft fuselage, using commercial rapid joint design, analysis, and optimization software. The rapid joint design tool was investigated as a substitute and/or complement to a finite element analysis software. A composite Pi-joint and a composite Y-joint were evaluated using the rapid joint design tool to determine the applicability and limits of the software. Furthermore, three main preliminary parametric studies were performed to better understand the capability of the tool in predicting the stress distributions and trends in the Y-joint. The parameters investigated were the joint curvature, the laminated skin thickness, the adhesive systems, and the ply composition. Lastly, trends in predicted failure load were produced as a function of skin thickness (16ply, 24ply and 32ply). Failure loads were found with varying joint curvature and skin thickness using stress-based adherend failure criterion. The rapid joint design tool was also validated against existing experimental results.

Bonded Joints↗

Analysis by NASA's VESGEN Software of Retinal Blood Vessels in Human Subjects Undergoing Head-Down Tilt During 70-Day Bed Rest

Significant risks for visual impairment associated with increased intracranial pressure (VIIP) are incurred by microgravity spaceflight, especially long-duration missions [1]. We hypothesize that microgravity-induced fluid shifts result in pathological changes within blood vessels of the retina that precede development of visual and other ocular impairments. Potential contributions of retinal vascular remodeling to VIIP etiology are therefore being investigated for two studies in 30deg infrared (IR) Heidelberg Spectralis(Registered Trademark) images with NASA's innovative VESsel GENeration Analysis (VESGEN) software [2,3]. The retrospective studies include: (1) before, during and after (pre, mid and post) 6º head-down tilt (HDT) in human subjects during 70 days of bed rest, and (2) before and after missions to the International Space Station (ISS) by U.S. crew members. Results for both studies are almost complete. A preliminary example for HDT is described below.

Microgravity↗

Software Performs Complex Design Analysis

Designers use computational fluid dynamics (CFD) to gain greater understanding of the fluid flow phenomena involved in components being designed. They also use finite element analysis (FEA) as a tool to help gain greater understanding of the structural response of components to loads, stresses and strains, and the prediction of failure modes. Automated CFD and FEA engineering design has centered on shape optimization, which has been hindered by two major problems: 1) inadequate shape parameterization algorithms, and 2) inadequate algorithms for CFD and FEA grid modification. Working with software engineers at Stennis Space Center, a NASA commercial partner, Optimal Solutions Software LLC, was able to utilize its revolutionary, one-of-a-kind arbitrary shape deformation (ASD) capability-a major advancement in solving these two aforementioned problems-to optimize the shapes of complex pipe components that transport highly sensitive fluids. The ASD technology solves the problem of inadequate shape parameterization algorithms by allowing the CFD designers to freely create their own shape parameters, therefore eliminating the restriction of only being able to use the computer-aided design (CAD) parameters. The problem of inadequate algorithms for CFD grid modification is solved by the fact that the new software performs a smooth volumetric deformation. This eliminates the extremely costly process of having to remesh the grid for every shape change desired. The program can perform a design change in a markedly reduced amount of time, a process that would traditionally involve the designer returning to the CAD model to reshape and then remesh the shapes, something that has been known to take hours, days-even weeks or months-depending upon the size of the model.

Source record↗

Nuclear Space System Analysis and Modelling (NSSAM): A Software Tool to Efficiently Analyze the Design Space of Space Reactor Systems

Space reactors have the potential to play a key role in future NASA exploration activities due to their capability to enable sustainable power and advanced propulsion systems. To enable assessment of the space reactor design space, the nuclear space system analysis and modelling (NSSAM) software was developed by Analytical Mechanics Associates. NSSAM leverages a scalable and extensible software architecture which automates reactor analysis to perform coupled engine-reactor and reactor physics-thermal hydraulics calculations. This allows space reactor systems to be evaluated by a wider number of users with a consistent analysis approach to compare designs. NSSAM has been developed with multiple use cases to tailor the analysis to the level of detail desired by the user and computing resources. This summary overviews the NSSAM architecture and development approach, current capabilities (including design variants and use cases) and analysis approach for reactor and system component models.

nuclear thermal propulsion↗

SCA Tools - SCRM Value Add or Lossy Noise Machines

Software supply chain risk management (SCRM) depends upon accurate information regarding the software components that comprise any given software system. The collection of components included in a software package can be organized within a software bill of materials, or SBOM. SBOMs are ideally generated when the software components are put together, such as at compile time, but for many reasons that has not and is not always possible. For example, legacy or proprietary software packages often do not have SBOMs available to downstream consumers of that software. It’s not just end users that are affected, manufacturers themselves also must deal with this problem. To answer these questions, the market has seen the rise of several commercial software composition analysis (SCA) tools. These tools aim to peer into completed software systems, automatically identifying hidden software dependencies and looking up known vulnerabilities associated with those dependencies to enable end-users to enhance their cyber supply chain risk management processes. These tools are potentially a huge boon to end users of legacy and proprietary software – and a potential bane, depending on how accurate they are. This research asks that question – how accurate are currently available binary SCA tools – and provides answers to several other questions: What does it mean to be “accurate”? What limitations do the tools have in identifying common edge cases that take place in modern software development? Can they help you avoid a devastating supply chain attack, or is it all just noise? After researching SCA tools on the market, we identified three vendors that fit our use case and would provide analysis on compiled binaries. Using these tools, we submitted firmware for critical infrastructure devices for analysis and SBOM generation. The SBOM outputs were then cross referenced with SBOMs generated through manual analysis for comparison. In addition to the firmware samples, we also submitted edge case samples based off a popular open-source library that were specifically crafted to evaluate each tools’ ability to accurately identify components. These samples were customized to be consistent with modifications we have seen in modern software development as well as a couple that are representative of supply chain attacks.

97 MATHEMATICS AND COMPUTING↗

Validation of CFD/Heat Transfer Software for Turbine Blade Analysis

I am an intern in the Turbine Branch of the Turbomachinery and Propulsion Systems Division. The division is primarily concerned with experimental and computational methods of calculating heat transfer effects of turbine blades during operation in jet engines and land-based power systems. These include modeling flow in internal cooling passages and film cooling, as well as calculating heat flux and peak temperatures to ensure safe and efficient operation. The branch is research-oriented, emphasizing the development of tools that may be used by gas turbine designers in industry. The branch has been developing a computational fluid dynamics (CFD) and heat transfer code called GlennHT to achieve the computational end of this analysis. The code was originally written in FORTRAN 77 and run on Silicon Graphics machines. However the code has been rewritten and compiled in FORTRAN 90 to take advantage of more modem computer memory systems. In addition the branch has made a switch in system architectures from SGI's to Linux PC's. The newly modified code therefore needs to be tested and validated. This is the primary goal of my internship. To validate the GlennHT code, it must be run using benchmark fluid mechanics and heat transfer test cases, for which there are either analytical solutions or widely accepted experimental data. From the solutions generated by the code, comparisons can be made to the correct solutions to establish the accuracy of the code. To design and create these test cases, there are many steps and programs that must be used. Before a test case can be run, pre-processing steps must be accomplished. These include generating a grid to describe the geometry, using a software package called GridPro. Also various files required by the GlennHT code must be created including a boundary condition file, a file for multi-processor computing, and a file to describe problem and algorithm parameters. A good deal of this internship will be to become familiar with these programs and the structure of the GlennHT code. Additional information is included in the original extended abstract.

Kiefer, Walter D.↗

Certification of CFD heat transfer software for turbine blade analysis

Accurate modeling of heat transfer effects is a critical component of the Turbine Branch of the Turbomachinery and Propulsion Systems Division. Being able to adequately predict and model heat flux, coolant flows, and peak temperatures are necessary for the analysis of high pressure turbine blades. To that end, the primary goal of my internship this summer will be to certify the reliability of the CFD program GlennHT for the purpose of turbine blade heat transfer analysis. GlennHT is currently in use by the engineers in the Turbine Branch who use the FORTRAN 77 version of the code for analysis. The program, however, has been updated to a FORTRAN 90 version which is more robust than the older code. In order for the new code to be distributed for use, its reliability must first be certified. Over the course of my internship I will create and run test cases using the FORTRAN 90 version of GlennHT and compare the results to older cases which are known to be accurate, If the results of the new code match those of the sample cases then the newer version will be one step closer to certification for distribution. In order to complete these it will first be necessary to become familiar with operating a number of other programs. Among them are GridPro, which is used to create a grid mesh around a blade geometry, and FieldView, whose purpose is to graphically display the results from the GlennHT program. Once enough familiarity is established with these programs to render them useful, then the work of creating and running test scenarios will begin. The work is additionally complicated by a transition in computer hardware. Most of the working computers in the Turbine Branch are Silicon Graphics machines, which will soon be replaced by LINUX PC's. My project is one of the first to make use the new PC's. The change in system architecture however, has created several software related issues which have greatly increased the time and effort investments required by the project.Although complications with the project continue to arise, it is expected that the goal of my internship can still be achieved within the remaining time period. Critical steps have been achieved and test scenarios can now be designed and run. At the completion of my internship, the FORTRAN 90 version of GlennHT should be well on its way to certification.

Jordan, William A.↗

Digital X-ray Pipe Inspector Software

The Digital X-ray Pipe Inspector software requires a digital x-ray image of a pipe as input to the program, such as the image in Attachment A Figure 1. The image may be in a variety of software formats such as bitmap, jpeg, tiff, DICOM or DICONDE. The software allows the user to interactively select a region of interest from the image for analysis. This software is used to analyze digital x-ray images of pipes to evaluate loss of wall thickness. The software specifically provides tools to analyze the image in (a) the pipe walls, (b) between the pipe walls. Traditional software uses only the information at the pipe wall while this new software also evaluates the image between the pipewalls. This makes the inspection process faster, more thorough, more efficient, and reduces expensive reshots. Attachment A Figure 2 shows a region of interest (a green box) drawn by the user around an anomaly in the pipe wall. This area is automatically analyzed by the external pipe wall tool with the result shown in Attachment A Figure 3. The edges of the pipe wall are detected and highlighted in yellow and areas where the wall thickness in less the the minimum wall threshold are shown in red. These measurements are typically made manually in other software programs, which lead to errors and inconsistency because the location of the edges are estimated by the user. Attachment A Figure 4 shows a region of interest (a green box) drawn by the user between the pipe walls. As can be seen there are intensity anomalies that correspond to wall defects. However, this information is not used directly by other software programs. In order to fully investigate these anomalies, the pipe would be reinspected in a different orientation to attempt to obtain a view of the anomaly in the pipe wall rather than the interior of the pipe. The pipe may need to be x-rayed a number of times to obtain the correct orientation. This is very costly and time consuming. The new software can perform the analysis directly on the intensity information in the original image. Figures 5 through 9 in Attachment A show wall defects in red for various percents of wall thickness loss. For example, Figure 5 show defects (in red) where the wall thickness is 95% or less than the nominal wall thickness (or a 5% or greater wall thickness loss). Wall thicknesses can be given in absolute terms as well.

Gibbs, Kenneth M.↗

Interactive statistical decision tools (GiSdT): An open source software integration of decision analysis and stakeholder judgment for sustainable waste management, disposal and remediation - 15650

The vast majority of remediation and waste management decisions are made without quantitative consideration of economic and socio-political factors. They are made instead based on quantitative metrics of human health risk. Sustainable decisions need to be made based on all three 'pillars of sustainability' (economics, environment and social), and require understanding and characterization of the costs and values associated with each pillar. In addition, such decisions need to conform to regulatory or other legal requirements, which often constrains the decision space of interest. Although efforts are often made to include factors across all three pillars (for example, for decisions made under CERCLA), these efforts are usually qualitative, and hence difficult to defend. They lack technical defensibility, transparency and traceability. The purpose of GiSdT (Guided Interactive Statistical Decision Tools) is to provide a quantitative framework whereby all aspects of a decision problem, such as remediation and waste management decisions, can be addressed quantitatively, and hence, defensibly, transparently and traceably. Most decision-makers do not currently have access to useful or usable methods and approaches when are presented with choices that have significant impacts across all three pillars of sustainability. The goal of GiSdT is to provide that access by identifying or developing effective and user-friendly decision methods and approaches that empower decision-makers to explicitly and routinely incorporate all aspects of sustainability into their decision-making. To identify and develop these methods and approaches, GiSdT provides the tools needed for decision-makers and stakeholders to understand and characterize their knowledge of their current decision-making processes, and what methods and approaches they need to pro-actively and quantitatively address all aspects of sustainability in their decisions. GiSdT is an open source interactive framework program that provides the tools needed to address the relevant components of a sustainability-based decision problem, including describing the decision landscape, translating that landscape into goals and objectives, valuing the measurable attributes that describe each objective, identifying decision options and addressing the uncertainty in the attributes (e.g., human health risk, institutional controls) through appropriate probabilistic models. In addition to addressing these quantitative technical components, the GiSdT program is aimed at facilitating stakeholder involvement so that the perspectives, values and objectives are all relevant stakeholders are addressed explicitly in the decision making process. The technical underpinnings of our software program, called Guided Interactive Statistical Decision Tools (GiSdT), are described. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Application of software technology to automatic test data analysis

The verification process for a major software subsystem was partially automated as part of a feasibility demonstration. The methods employed are generally useful and applicable to other types of subsystems. The effort resulted in substantial savings in test engineer analysis time and offers a method for inclusion of automatic verification as a part of regression testing.

Stagner, J. R.↗

Analysis of a hardware and software fault tolerant processor for critical applications

Computer systems for critical applications must be designed to tolerate software faults as well as hardware faults. A unified approach to tolerating hardware and software faults is characterized by classifying faults in terms of duration (transient or permanent) rather than source (hardware or software). Errors arising from transient faults can be handled through masking or voting, but errors arising from permanent faults require system reconfiguration to bypass the failed component. Most errors which are caused by software faults can be considered transient, in that they are input-dependent. Software faults are triggered by a particular set of inputs. Quantitative dependability analysis of systems which exhibit a unified approach to fault tolerance can be performed by a hierarchical combination of fault tree and Markov models. A methodology for analyzing hardware and software fault tolerant systems is applied to the analysis of a hypothetical system, loosely based on the Fault Tolerant Parallel Processor. The models consider both transient and permanent faults, hardware and software faults, independent and related software faults, automatic recovery, and reconfiguration.

Dugan, Joanne B.↗

PyApprox: A software package for sensitivity analysis, Bayesian inference, optimal experimental design, and multi-fidelity uncertainty quantification and surrogate modeling

PyApprox is a Python-based one-stop-shop for probabilistic analysis of numerical models such as those used in the earth, environmental and engineering sciences. Easy to use and extendable tools are provided for constructing surrogates, sensitivity analysis, Bayesian inference, experimental design, and forward uncertainty quantification. The algorithms implemented represent a wide range of methods for model analysis developed over the past two decades, including recent advances in multi-fidelity approaches that use multiple model discretizations and/or simplified physics to significantly reduce the computational cost of various types of analyses. An extensive set of Benchmarks from the literature is also provided to facilitate the easy comparison of new or existing algorithms for a wide range of model analyses. Here, this paper introduces PyApprox and its various features, and presents results demonstrating the utility of PyApprox on a benchmark problem modeling the advection of a tracer in groundwater.

54 ENVIRONMENTAL SCIENCES↗

Development of Automated Software Program for the Analysis of Alzheimer's Disease Scans: Evaluation of PET imaging with PBR-111 in HV and AD subjects

Study goal: A Phase 1 evaluation of the kinetics, clearance and cerebral distribution of one novel peripheral benzodiazepine receptors(PBR)positron emission tomography (PET) imaging agent, 18F-PBR-111 following intravenous administration in healthy volunteers and Alzheimer's disease (AD) patients. Short title: Evaluation of PET imaging with PBR-111 in HV and AD subjects Proof of Mechanism. Primary Objective: To evaluate the cerebral distribution of PBR-111 positron emission tomography (PET) for detection/exclusion of microglial activation in patients with Alzheimer's disease subjects compared to healthy volunteers. Secondary objectives: - To assess the dynamic uptake and washout of [18F]PBR-111, a potential imaging bio-marker for inflammatory changes in brain, using positron emission tomography in subjects with Alzheimer's disease (AD) and healthy volunteers (HV). - To perform blood metabolite characterization of [18F]PBR-111 in subjects with AD and HV to determine the nature of metabolites in assessment of [18F]-PBR-111 as a PET brain imaging agent. Name of radioactive drug substance: PBR-111 Dose(s): The applied PBR-111 radioactive dose will be up to 5.0 mCi, diluted in a maximum of 10 ml of saline. The radioligand will be administered as a slow intravenous bolus injection (i.e., 6 sec/ml) into a large vein (e.g., antecubital vein). Route of administration: Intravenous injection Duration of treatment: Single administration of a diagnostic agent Indication: PBR-111 positron emission tomography (PET) imaging has the potential to detect microglial activation. In the presence of PBR-111 uptake (representative of microglial activation), inflammation in the brain can be detected. Diagnosis and main criteria for inclusion: Study participants will be HVs and patients diagnosed with probable AD. HVs must be 18 years of age (at least four subjects 50 years of age) and have no evidence of cognitive impairment or other neurologic disease by medical history. The lack of cognitive impairment will also be based on a Clinical Dementia Rating (CDR) of 0. Patients with probable AD must be 50 years of age and must fulfill the National Institute of Neurological and Communicative Disorders and Stroke, Alzheimer's Disease and Related Disorders Association [NINCDS-ADRDA] criteria for probable AD. The CDR score must be 1.0 and 2.0 and have a modified Hachinski of 4. All HVs and all patients with probable AD must be able to comply with all study procedures. Study design: This is a Phase 1, open-label, single-center, non-randomized single dose study to assess the kinetics, clearance and cerebral distribution of PBR-111 PET imaging in detecting microglial activation in the brain in patients with probable AD compared to HVs. All aspects related to image acquisition, processing, and visual as well as quantitative evaluation will be developed, optimized, and validated (where required). Each subject will be required to visit the study center during the screening phase and on the PBR-111 PET imaging day (baseline). A telephone follow-up visit will be performed 7 days (± 3 days) after PBR-111 PET administration. At the screening visit, each subject (or caregiver in the case of AD subjects) will be asked to provide written informed consent or assent. During the screening phase (maximum duration of 60 days) subject medical, neurological, and surgical history, clinical assessments, and a neuro-psychiatric evaluation will be performed on all eligible subjects. Subjects will be allowed to leave the center after all evaluations have been completed. During this period an MRI of the brain will be performed during the screening period. If an MRI of the brain has been performed within six months of the imaging visit using the methods described in the protocol, and there has been no medically significant events in the interim, the previous MRI may be used. During the PBR-111 PET imaging day, all subjects will receive a single intravenous injection of PBR-111 and scanning will be performed over a 3.5 hour period. Each subject will have a telephone follow-up 7 days (± 3 days) thereafter to assess for adverse events. Methodology: - Assessments to provide clinical characterization of the AD subjects will be performed. - After administration of PBR-111, images will be generated with state-of-the-art PET imaging. Images will be assessed quantitatively for the presence of microglial activation by a nuclear physician blinded to clinical data. - Total radioactivity and estimation of the fraction of radioactivity associated to the un-metabolized tracer will be determined. In addition, the metabolite patterns of PBR-111 are determined in venous plasma and arterial samples based on high-performance liquid chromatography (HPLC) analyses. - Arterial sampling will be acquired in the initial two AD and two HV subjects and modeling will be assessed to determine if additional arterial sampling is necessary.

97 MATHEMATICS AND COMPUTING↗