Search NASA⌕ Search

SEARCH · Search NASA

Results for “Beam Distribution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,189 records · Page 66

An analysis of the influence of impurities on fast particle attenuation and on fast ion spectral shape in LHD

Neutral particle fluxes measured by neutral particle analyzers can provide information about the ion temperature as well as the non-Maxwellian anisotropic ion distribution tails from neutral beam injection and ion cyclotron radio frequency heating. In the case of multidirectional diagnostics employing high resolution atomic energy spectrometers, the neutral atomic flux source is not localized in contrast to pellet charge exchange or diagnostic neutral beam methods. The correct interpretation of such measurements from plasma in a complex toroidally asymmetric geometry, like that of LHD, requires careful numerical modeling of the neutral flux formation. Previously a measured neutral flux calculation scheme was developed and was used for the LHD geometry and a suitable analytic expression for ionization cross sections {sigma}{sub s}{sup (z)}(E,n{sub e},T{sub e},Z{sub eff}) of impurities was formulated by Janev et al. [Nucl. Fusion 29, 2125 (1989)]. In this paper, the attenuation of fast particles by impurities is incorporated into the neutral flux calculation scheme and the influence of impurities on the calculated neutral flux spectra is shown. Finally, the behavior of the calculated and experimental suprathermal particle distributions is compared for pure hydrogen and for argon impurity seeded plasmas.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Final Technical Report - Rapid Surface Microanalysis using a Low Temperature Plasma

This project focused on improving our current understanding and scientific knowledge in the area of plasma-surface interactions and plasma assisted material synthesis related to advanced microelectronics and nanotechnology. Current challenges include: controlling the interaction of Low Temperature Plasma (LTP) with a single layer of atoms to manufacture integrated circuits, continued miniaturization of integrated circuits, LTP processing of material surfaces and thin films to enable industrial scale fabrication of advanced microelectronics, synthesis of new materials, nanomaterials, nanotubes, and complex materials, Technology developed in this subtopic is of value to either (i) enable scans of surfaces (~1 sq. cm area) using various microscopies (electron, optical, other) at high resolution (micron or sub-micron resolution) rapidly (hours or days rather than years to complete a high-resolution scan of such a large surface area), or (ii) enable scans of surfaces (~1 sq. cm area) using various microscopies (electron, optical, other) at relatively low resolution rapidly, then apply algorithms to select spots for micron-scale imaging. Sputtering occurs when particles of a solid material are ejected from its surface by energetic particles from a plasma. While the degradation of the solid material and the subsequent deposition of the ejected material onto vulnerable surfaces are the usual subjects of sputtering studies, plasma science has yet to be combined with sputtering to create new diagnostics devices and systems. Small changes in the design of the plasma discharge device make it possible to create broad plasma beams for rapid scanning or small plasma beams to obtain the distribution of ejected elements with micron resolution. In the high-resolution use, the ion flux is extracted from the gas-discharge plasma and focused by a spherical emission surface to micron sizes onto the target specimen, providing very local sputtering and local elemental analysis. We call this “self-focusing”. The radiation from the excited and ionized sputtered atoms is recorded by a spectrometer through a window and fiberglass cable and analyzed with standard software packages used for optical glow discharge spectroscopy. Computer simulations of beam formation were used to verify and optimize the designs to be tested. A prototype was designed, constructed, and used to start experiments of beam formation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

SU-E-T-601: Output Factor Calculation of Irregular Shape Electron Cutout at Extended SSD

Purpose: To calculate the output factor of irregular shape electron beam at extended SSD using modified lateral build-up-ratio method. Methods: Circular cutouts from 2.0cm diameter to maximum possible sizes were prepared for applicator cone size of 15×15cm. In addition, different irregular cutouts were prepared. Percentage depth dose (PDD) curves were measured for each cutout using 6, 9, 12 and 16-MeV at the standard SSD of 100cm. The scanning was done using Multidata system and Scanditronix diodes on 2100SC Varian LINAC. In addition, for each cutout and electron beam energy doses were measured at SSD values of 100, 105, 110, 115cm using EDR2 films and diodes. Results: The measured PDD were normalized to the depth of 1.0mm. The lateral build-up-ratio (LBR) and the lateral scatter parameter (sigma) were calculated for each circular cutout using the open 15X15-cm2 field as the reference field. Taking the linear increase of sigma with cutout size into account, PDD of the irregular cutouts were calculated at 100 cm SSD. Furthermore, using the dose measured at different SSDs, the effective SSD value for each circular cutout and electron beam energy was determined. Employing the LBR and the effective-SSD values of the circular cutouts along with the calculated PDD of the irregular cutouts, the output factors of the irregular cutout at different extended SSD values were calculated. Finally, the calculated output factors were compared with the measured values. Conclusion: In this research, it is shown that output factor of irregular shape electron beam at extended SSD can be determined by using the LBR and the effective SSD values of circular cutouts. The percentage difference of the calculated output factor from the measured output factor for irregular cutouts at extended SSD were within 3.0%.

07 ISOTOPE AND RADIATION SOURCES↗

FEM design and simulation of a short, 10 MV, S-band Linac with Monte Carlo dose simulations

Purpose: Current commercial 10 MV Linac waveguides are 1.5 m. The authors’ current 6 MV linear accelerator–magnetic resonance imager (Linac–MR) system fits in typical radiotherapy vaults. To allow 10 MV treatments with the Linac–MR and still fit within typical vaults, the authors design a 10 MV Linac with an accelerator waveguide of the same length (27.5 cm) as current 6 MV Linacs. Methods: The first design stage is to design a cavity such that a specific experimental measurement for breakdown is applicable to the cavity. This is accomplished through the use of finite element method (FEM) simulations to match published shunt impedance, Q factor, and ratio of peak to mean-axial electric field strength from an electric breakdown study. A full waveguide is then designed and tuned in FEM simulations based on this cavity design. Electron trajectories are computed through the resulting radio frequency fields, and the waveguide geometry is modified by shifting the first coupling cavity in order to optimize the electron beam properties until the energy spread and mean energy closely match values published for an emulated 10 MV Linac. Finally, Monte Carlo dose simulations are used to compare the resulting photon beam depth dose profile and penumbra with that produced by the emulated 10 MV Linac. Results: The shunt impedance, Q factor, and ratio of peak to mean-axial electric field strength are all matched to within 0.1%. A first coupling cavity shift of 1.45 mm produces an energy spectrum width of 0.347 MeV, very close to the published value for the emulated 10 MV of 0.315 MeV, and a mean energy of 10.53 MeV, nearly identical to the published 10.5 MeV for the emulated 10 MV Linac. The depth dose profile produced by their new Linac is within 1% of that produced by the emulated 10 MV spectrum for all depths greater than 1.5 cm. The penumbra produced is 11% narrower, as measured from 80% to 20% of the central axis dose. Conclusions: The authors have successfully designed and simulated an S-band waveguide of length of 27.5 cm capable of producing a 10 MV photon beam. This waveguide operates well within the breakdown threshold determined for the cavity geometry used. The designed Linac produces depth dose profiles similar to those of the emulated 10 MV Linac (waveguide-length of 1.5 m) but yields a narrower penumbra.

07 ISOTOPE AND RADIATION SOURCES↗

Solar wind suprathermal electron Stahl widths across high-speed stream structures

Suprathermal electrons (100-1500 eV) observed in the solar wind typically show a strahl distribution, that is, a beam directed away from the Sun along the magnetic field direction. The strahl width observed at 1 AU is highly variable, ranging from 10-70 degrees. The obsenred finite width of the strahl results from the competition between beam focusing as the interplanetary magnetic field strength drops with distance from the Sun, and pitch-angle scattering as the beam interacts with the solar wind plasma in transit from the sun. Here we examine strahl width, observed with ACE SWEPAM across high-speed stream structures to investigate variations in electron scattering as a function of local plasma characteristics. We find that narrow strahls (less than 20 degrees wide), indicating reduced scattering, are observed within high-speed streams. Narrow strahls are also observed in both very low temperature solar wind, in association with ICMEs. Case studies of high-speed streams typically show the strahl narrowing at the leading edge of the stream. In some cases, the strahl narrows at the reverse shock or pressure wave, in other cases at the stream interface. The narrowing can either occur discontinuously or gradually over a period of hours. Within the high-speed wind, the strahl remains narrow for a period of hours to days, and then gradually broadens. The strahl width is roughly constant at all energies across these structures. For some fraction of high-speed streams, counterstreaming is associated with passage of the corotating interaction region. In these cases, we find the widths of the two counterstreaming beams frequently differ by more than 40 degrees. This dramatic difference in strahl width contrasts with observations in the solar wind as a whole, in which counterstreaming strahls typically differ in width by less than 20 degrees.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Mechanism of heat-modification inside a glass after irradiation with high-repetition rate femtosecond laser pulses

Accumulation of thermal energies by highly repeated irradiation of femtosecond laser pulses inside a glass induces the heat-modification whose volume is much larger than that of the photoexcited region. It has been proposed that the heat-modification occurs in the region in which the temperature had overcome a threshold temperature during exposure of laser pulses. In order to understand the mechanism of the heat-modification, we investigated the temperature distribution during laser exposure and the threshold temperature by analyzing the volume of the modification based on a thermal diffusion model. We found that the threshold temperature becomes lower with increasing laser exposure time. The dependence of the threshold temperature on the laser exposure time was explained by the deformation mechanism based on the temperature-dependent viscosity and viscoelastic behavior of a glass under a stress loading by thermal expansion. The deformation mechanism also could simulate a tear-drop shape of a heat-modification by simultaneous double-beams' irradiation and the distribution of birefringence in a heat-modification. The mechanism proposed in this study means that the temperature-dependence of the viscosity of a glass should be essential for predicting and controlling the heat-modification.

36 MATERIALS SCIENCE↗

Characteristics of miniature electronic brachytherapy x-ray sources based on TG-43U1 formalism using Monte Carlo simulation techniques

Purpose: The goal of this study is to determine a method for Monte Carlo (MC) characterization of the miniature electronic brachytherapy x-ray sources (MEBXS) and to set dosimetric parameters according to TG-43U1 formalism. TG-43U1 parameters were used to get optimal designs of MEBXS. Parameters that affect the dose distribution such as anode shapes, target thickness, target angles, and electron beam source characteristics were evaluated. Optimized MEBXS designs were obtained and used to determine radial dose functions and 2D anisotropy functions in the electron energy range of 25-80 keV. Methods: Tungsten anode material was considered in two different geometries, hemispherical and conical-hemisphere. These configurations were analyzed by the 4C MC code with several different optimization techniques. The first optimization compared target thickness layers versus electron energy. These optimized thicknesses were compared with published results by Ihsan et al.[Nucl. Instrum. Methods Phys. Res. B 264, 371-377 (2007)]. The second optimization evaluated electron source characteristics by changing the cathode shapes and electron energies. Electron sources studied included; (1) point sources, (2) uniform cylinders, and (3) nonuniform cylindrical shell geometries. The third optimization was used to assess the apex angle of the conical-hemisphere target. The goal of these optimizations was to produce 2D-dose anisotropy functions closer to unity. An overall optimized MEBXS was developed from this analysis. The results obtained from this model were compared to known characteristics of HDR {sup 125}I, LDR {sup 103}Pd, and Xoft Axxent electronic brachytherapy source (XAEBS) [Med. Phys. 33, 4020-4032 (2006)]. Results: The optimized anode thicknesses as a function of electron energy is fitted by the linear equation Y ({mu}m) = 0.0459X (keV)-0.7342. The optimized electron source geometry is obtained for a disk-shaped parallel beam (uniform cylinder) with 0.9 mm radius. The TG-43 distribution is less sensitive to the shape of the conical-hemisphere anode than the hemispherical anode. However, the optimized apex angle of conical-hemisphere anode was determined to be 60 deg. For the hemispherical targets, calculated radial dose function values at a distance of 5 cm were 0.137, 0.191, 0.247, and 0.331 for 40, 50, 60, and 80 keV electrons, respectively. These values for the conical-hemisphere targets are 0.165, 0.239, 0.305, and 0.412, respectively. Calculated 2D anisotropy functions values for the hemispherical target shape were F(1 cm, 0 deg.) = 1.438 and F(1 cm, 0 deg.) = 1.465 for 30 and 80 keV electrons, respectively. The corresponding values for conical-hemisphere targets are 1.091 and 1.241, respectively. Conclusions: A method for the characterizations of MEBXS using TG-43U1 dosimetric data using the MC MCNP4C has been presented. The effects of target geometry, thicknesses, and electron source geometry have been investigated. The final choices of MEBXS design are conical-hemisphere target shapes having an apex angle of 60 deg. Tungsten material having an optimized thickness versus electron energy and a 0.9 mm radius of uniform cylinder as a cathode produces optimal electron source characteristics.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Beam spin asymmetries in deeply virtual Compton scattering (DVCS) with CLAS at 4.8 GeV

We report measurements of the beam spin asymmetry in deeply virtual Compton scattering (DVCS) at an electron beam energy of 4.8 GeV using the CLAS detector at the Thomas Jefferson National Accelerator Facility. The DVCS beam spin asymmetry has been measured in a wide range of kinematics, 1.0<Q{sup 2}<2.8 (GeV/c){sup 2}, 0.12<x{sub B}<0.48, and 0.1<-t<0.8 (GeV/c){sup 2}, using the reaction e-vector p{yields}e{sup '}pX. The number of H(e,e{sup '}{gamma}p) and H(e,e{sup '}{pi}{sup 0}p) events are separated in each (Q{sup 2},x{sub B},t) bin by a fit to the line shape of the H(e,e{sup '}p)X M{sub x}{sup 2} distribution. The validity of the method was studied in detail using experimental and simulated data. It was shown that with the achieved missing mass squared resolution and the available statistics, the separation of DVCS-Bethe-Heitler and {pi}{sup 0} events can reliably be done with less than 5% uncertainty. Also, the Q{sup 2} and t dependences of the sin{phi} moments of the asymmetry are extracted and compared with theoretical calculations.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Dose distribution of a 125 keV mean energy microplanar x-ray beam for basic studies on microbeam radiotherapy

A multislit collimator was designed and fabricated for basic studies on microbeam radiation therapy (MRT) with an x-ray energy of about 100 keV. It consists of 30 slits that are 25 {mu}m high, 30 mm wide, and 5 mm thick in the beam direction. The slits were made of 25 {mu}m-thick polyimide sheets that were separated by 175 {mu}m-thick tungsten sheets. The authors measured the dose distribution of a single microbeam with a mean energy of 125 keV by a scanning slit method using a phosphor coupled to a charge coupled device camera and found that the ratios of the dose at the center of a microbeam to that at midpositions to adjacent slits were 1050 and 760 for each side of the microbeam. This dose distribution was well reproduced by the Monte Carlo simulation code PHITS.

61 RADIATION PROTECTION AND DOSIMETRY↗

Defects and 3D structural inhomogeneity in electron beam additively manufactured Inconel 718

Highlights: • A protocol for 3D characterization of structure and defects in additively manufactured EBM 718 is presented. • Lack of fusion defects disrupt local microstructure, creating isolated regions of equiaxed grains. • Clustering of micron-scale nitrides is attributed to a particle rafting process. • Normalized size-number density relationship of carbides matches that of industrial ingots. • Removal of porosity via post-processing will not correct microstructural inhomogeneities created by lack of fusion defects. - Abstract: Material structure and defects created during additive manufacturing contribute to the variability in mechanical properties of these parts, limiting their use for critical applications. Three-dimensional crystallographic, structural, and chemical information in electron beam melted Inconel 718 was collected from the sub-micron to the millimeter scale using the TriBeam tomography system. The relationship of defects to the surrounding microstructure has been studied in detail. Lack of fusion defects created sharp discontinuities in the grain morphology that extended several build layers beyond the layer where the defect originated. Nitrides and carbides in the size range of 1.25 μm to 10 μm were observed throughout the volume, with pronounced nitride clustering. The similarities between solidification in additive manufacturing and traditional manufacturing processes are demonstrated by the comparable size and distribution of carbides measured for industrial-scale samples of 718. Defects created during additive manufacturing cannot be easily remedied via standard post-processing techniques, and will likely diminish the mechanical performance of additively manufactured parts.

36 MATERIALS SCIENCE↗

Ion-acoustic-like waves excited by the reflected ions at the earth's bow shock

Some model distributions based on recent observations and simulations of the plasma at the earth's bow shock are found to be unstable to obliquely propagating electrostatic instabilities. The model distributions consist of either an ion beam or an ion velocity ring accompanied by a bi-Maxwellian background ion distribution and a flattop electron distribution. Ion anisotropies and nonthermal electrons are capable of significantly lowering the threshold of the ion beam instability. The generated waves share many properties in common with the ion acoustic waves that have been observed at the earth's bow shock. The results also indicate the importance of an anisotropy in the background ion velocity distribution in identifying sources of the ion-acoustic-like waves observed in the ion foreshock and the solar wind.

Akimoto, K.↗

Infrared bands of neutral gas-phase carbon clusters in a broad spectral range

The identification of species in the interstellar medium requires precise and molecule-specific spectroscopic information in the laboratory framework, in broad spectral ranges and under conditions relevant to interstellar environments. In this work, we measure the gas-phase infrared spectra of neutral carbon clusters, C N (N = 6–11), in a molecular beam. The C N distribution is formed by photofragmentation of C 60 molecules, concurrently showing a top-down formation mechanism. A broad spectral range in the infrared between 500–3200 cm -1 (20–3.125 μm) is investigated. We observe strong bands between 5 and 6 μm, in conjunction with novel features in the 3 μm region. Density functional theory calculations reveal that these short wavelength modes correspond to combination bands with significant infrared intensity. Moreover, we identify the N ≤ 10 clusters as linear, while C 11 adopts a ring configuration, placing the linear-to-ring transition at N = 11 under our molecular beam conditions. The linearity of C 10 is discussed based on the formation pathway from larger clusters in energetic conditions. Given the vast and very precise infrared information already been released from the James Webb Space Telescope mission, this infrared spectroscopic data set in conjunction with information on formation mechanisms is of major relevance for identifying neutral carbon clusters in astronomical environments.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Electron dose distributions caused by the contact-type metallic eye shield: Studies using Monte Carlo and pencil beam algorithms

A metallic contact eye shield has sometimes been used for eyelid treatment, but dose distribution has never been reported for a patient case. This study aimed to show the shield-incorporated CT-based dose distribution using the Pinnacle system and Monte Carlo (MC) calculation for 3 patient cases. For the artifact-free CT scan, an acrylic shield machined as the same size as that of the tungsten shield was used. For the MC calculation, BEAMnrc and DOSXYZnrc were used for the 6-MeV electron beam of the Varian 21EX, in which information for the tungsten, stainless steel, and aluminum material for the eye shield was used. The same plan was generated on the Pinnacle system and both were compared. The use of the acrylic shield produced clear CT images, enabling delineation of the regions of interest, and yielded CT-based dose calculation for the metallic shield. Both the MC and the Pinnacle systems showed a similar dose distribution downstream of the eye shield, reflecting the blocking effect of the metallic eye shield. The major difference between the MC and the Pinnacle results was the target eyelid dose upstream of the shield such that the Pinnacle system underestimated the dose by 19 to 28% and 11 to 18% for the maximum and the mean doses, respectively. The pattern of dose difference between the MC and the Pinnacle systems was similar to that in the previous phantom study. In conclusion, the metallic eye shield was successfully incorporated into the CT-based planning, and the accurate dose calculation requires MC simulation.

61 RADIATION PROTECTION AND DOSIMETRY↗

Polarization-independent silicon metadevices for efficient optical wavefront control

In this study, we experimentally demonstrate a functional silicon metadevice at telecom wavelengths that can efficiently control the wavefront of optical beams by imprinting a spatially varying transmittance phase independent of the polarization of the incident beam. Near-unity transmittance efficiency and close to 0–2π phase coverage are enabled by utilizing the localized electric and magnetic Mie-type resonances of low-loss silicon nanoparticles tailored to behave as electromagnetically dual-symmetric scatterers. We apply this concept to realize a metadevice that converts a Gaussian beam into a vortex beam. The required spatial distribution of transmittance phases is achieved by a variation of the lattice spacing as a single geometric control parameter.

36 MATERIALS SCIENCE↗

Simulation of diatomic gas-wall interaction and accommodation coefficients for negative ion sources and accelerators

Particle-wall interactions determine in different ways the operating conditions of plasma sources, ion accelerators, and beams operating in vacuum. For instance, a contribution to gas heating is given by ion neutralization at walls; beam losses and stray particle production—detrimental for high current negative ion systems such as beam sources for fusion—are caused by collisional processes with residual gas, with the gas density profile that is determined by the scattering of neutral particles at the walls. This paper shows that Molecular Dynamics (MD) studies at the nano-scale can provide accommodation parameters for gas-wall interactions, such as the momentum accommodation coefficient and energy accommodation coefficient: in non-isothermal flows (such as the neutral gas in the accelerator, coming from the plasma source), these affect the gas density gradients and influence efficiency and losses in particular of negative ion accelerators. For ideal surfaces, the computation also provides the angular distribution of scattered particles. Classical MD method has been applied to the case of diatomic hydrogen molecules. Single collision events, against a frozen wall or a fully thermal lattice, have been simulated by using probe molecules. Different modelling approximations are compared.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Compact Instrument for Measuring Profile of a Light Beam

The beamviewer is an optical device designed to be attached to a charge-coupled-device (CCD) image detector for measuring the spatial distribution of intensity of a beam of light (the beam profile ) at a designated plane intersecting the beam. The beamviewer-and-CCD combination is particularly well suited for measuring the radiant- power profile (for a steady beam) or the radiant-energy profile (for a pulsed beam) impinging on the input face or emerging from the output face of a bundle of optical fibers. The beamviewer and-CCD combination could also be used as a general laboratory instrument for profiling light beams, including beams emerging through small holes and laser beams in free space.

Papanyan, Valeri↗

Calibration of megavoltage cone-beam CT for radiotherapy dose calculations: Correction of cupping artifacts and conversion of CT numbers to electron density

Megavoltage cone-beam CT (MV CBCT) is used for three-dimensional imaging of the patient anatomy on the treatment table prior to or just after radiotherapy treatment. To use MV CBCT images for radiotherapy dose calculation purposes, reliable electron density (ED) distributions are needed. Patient scatter, beam hardening and softening effects result in cupping artifacts in MV CBCT images and distort the CT number to ED conversion. A method based on transmission images is presented to correct for these effects without using prior knowledge of the object's geometry. The scatter distribution originating from the patient is calculated with pencil beam scatter kernels that are fitted based on transmission measurements. The radiological thickness is extracted from the scatter subtracted transmission images and is then converted to the primary transmission used in the cone-beam reconstruction. These corrections are performed in an iterative manner, without using prior knowledge regarding the geometry and composition of the object. The method was tested using various homogeneous and inhomogeneous phantoms with varying shapes and compositions, including a phantom with different electron density inserts, phantoms with large density variations, and an anthropomorphic head phantom. For all phantoms, the cupping artifact was substantially removed from the images and a linear relation between the CT number and electron density was found. After correction the deviations in reconstructed ED from the true values were reduced from up to 0.30 ED units to 0.03 for the majority of the phantoms; the residual difference is equal to the amount of noise in the images. The ED distributions were evaluated in terms of absolute dose calculation accuracy for homogeneous cylinders of different size; errors decreased from 7% to below 1% in the center of the objects for the uncorrected and corrected images, respectively, and maximum differences were reduced from 17% to 2%, respectively. The presented method corrects the MV CBCT images for cupping artifacts and extracts reliable ED information of objects with varying geometries and composition, making these corrected MV CBCT images suitable for accurate dose calculation purposes.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Feasibility of Near-field ODR Beam-size Monitoring at 23 GeV at FACET

Extension of near-field optical diffraction radiation (ODR) imaging to the 23 GeV beams at the proposed FACET facility at SLAC has been evaluated. The beam-size sensitivity at the 10- to 20-{micro}m sigma level based on a simple model will be reported. Polarization effects are also seen to be important and will be discussed. The comparisons to previous experimental results and the modeling results indicate sufficient feasibility for planning of the experiments in the coming year.

43 PARTICLE ACCELERATORS↗