Search NASA⌕ Search

SEARCH · Search NASA

Results for “CONVENTIONAL RADIATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,189 records · Page 66

Reirradiation Tolerance of the Human Brain

Purpose: To give an overview of current available clinical data on reirradiation of glioma with respect to the tolerance dose of normal brain tissue. Methods and Materials: Clinical brain reirradiation studies from January 1996 to December 2006 were considered on radiation-induced late adverse effects-i.e., brain tissue necrosis. The studies were analyzed by using the linear quadratic model to derive information on the cumulative biologic effective tolerance dose and equivalent doses in 2-Gy fractions for the healthy human brain. Results: The cumulative dose in conventional reirradiation series (of 81.6-101.9 Gy) were generally lower than in fractionated stereotactic radiotherapy (FSRT) ( 90-133.9 Gy.) or LINAC-based stereotactic radiosurgery series (of 111.6-137.2 Gy). No correlation between the time interval between the initial and reirradiation course and the incidence of radionecrosis was noted. The analysis showed the prescribed to increase with decreasing treatment volume, which is allowed by modern conformal radiation techniques. Conclusion: Radiation-induced normal brain tissue necrosis is found to occur at >100 Gy. The applied reirradiation dose and increases with a change in irradiation technique from conventional to radiosurgery re-treatment, without increasing the probability of normal brain necrosis. Taken together, modern conformal treatment options, because of their limited volume of normal brain tissue exposure, allow brain reirradiation for palliative treatment of recurrent high grade glioma with an acceptable probability of radionecrosis.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A non-free-space propagation x-ray phase contrast imaging method sensitive to phase effects in two directions simultaneously

We present an x-ray phase contrast imaging method based on coded apertures sensitive to phase effects in two directions simultaneously. To date, this is the only non-free-space propagation approach with this capability. Whereas the use of free-space propagation methods is limited to synchrotron radiation or microfocal x-ray sources, which impose severe limits in terms of practical applicability, coded-aperture based methods have been shown to provide synchrotronlike phase contrast enhancements with conventional x-ray sources. A two-directional sensitive method working with conventional sources could create a breakthrough in medical imaging, where two-directional sensitivity is often a mandatory requirement.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

May 2011 Groundwater and Surface Water Sampling at the Rio Blanco, Colorado, Site (Data Validation Package)

Annual sampling was conducted at the Rio Blanco, Colorado, site for the Long-Term Hydrologic Monitoring Program May 16-17, 2011, to monitor groundwater and surface water for potential radionuclide contamination. Sampling and analyses were conducted as specified in Sampling and Analysis Plan for the U.S. Department of Energy Office of Legacy Management Sites (LMS/PRO/S04351, continually updated). A duplicate sample was collected from location Johnson Artesian WL. Samples were analyzed by the U.S. Environmental Protection Agency (EPA) Radiation&Indoor Environments National Laboratory in Las Vegas, Nevada. Samples were analyzed for gamma-emitting radionuclides by high-resolution gamma spectrometry, and for tritium using the conventional method. Tritium was not measured using the enrichment method because the EPA laboratory no longer offers that service. Results of this monitoring at the Rio Blanco site demonstrate that groundwater and surface water outside the boundaries have not been affected by project-related contaminants.

54 ENVIRONMENTAL SCIENCES↗

SU-E-I-64: X-Ray Coherent Scatter Mammography Simulation

Purpose: Conventional mammography has poor contrast between healthy and cancerous tissues due to the small difference in attenuation properties. Coherent scatter potentially provides more information because interference of coherently scattered radiation depends on the average intermolecular spacing, and can be used to characterize tissue types. However, typical coherent scatter analysis techniques are not compatible with rapid low dose screening modalities. Coherent scatter slot scan imaging is a novel imaging technique which provides new information with higher contrast. In this work a simulation was performed of coherent scatter slot scan imaging to assess its performance and provide system optimization. Methods: In coherent scatter imaging, the coherent scatter is exploited using a conventional slot scan mammography system with anti-scatter grids tilted at the characteristic angle of cancerous tissues. A Monte Carlo simulation was used to simulate the coherent scatter imaging. System optimization was performed across several parameters, including source voltage and filtration, tilt angle, source and grid distances, grid ratio, and shielding geometry. Results: The contrast was high and increased as the grid tilt angle was increased beyond the characteristic angle for the modeled carcinoma, and as the source voltage increased. Source filtration did not have a significant effect on contrast. Increasing grid ratio improved contrast at the expense of decreasing the signal to noise ratio (SNR). As the tumor size is decreased, additional shields to block the fat signal are necessary in order to detect the cancer signal. Conclusion: Coherent scatter analysis using a wide slot setup is promising as an enhancement for screening mammography. This work was supported by National Institutes of Health, # 7 R01EB009715.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Spatial profiles of photon chemical potential in near-field thermophotovoltaic cells

Emitted photons stemming from the radiative recombination of electron–hole pairs carry chemical potential in radiative energy converters. This luminescent effect can substantially alter the local net photogeneration in near-field thermophotovoltaic cells. Several assumptions involving the luminescent effect are commonly made in modeling photovoltaic devices; in particular, the photon chemical potential is assumed to be zero or a constant prescribed by the bias voltage. The significance of photon chemical potential depends upon the emitter temperature, the semiconductor properties, and the injection level. Hence, these assumptions are questionable in near-field thermophotovoltaic devices with nanoscale separation distances between the emitter and the cell. In the present work, an iterative solver that combines fluctuational electrodynamics with the drift-diffusion model is developed to tackle the coupled photon and charge transport problem, enabling the determination of the spatial profile of photon chemical potential beyond the detailed balance approach. Here, the difference between the results obtained by allowing the photon chemical potential to vary spatially and by assuming a constant value demonstrates the limitations of the conventional approaches. This study is critically important for performance evaluation of near-field thermophotovoltaic systems with nanoscale vacuum gaps.

30 DIRECT ENERGY CONVERSION↗

Machine Learning Moment Closure Models for the Radiative Transfer Equation III: Enforcing Hyperbolicity and Physical Characteristic Speeds

This is the third paper in a series in which we develop machine learning (ML) moment closure models for the radiative transfer equation. In our previous work (Huang et al. in J Comput Phys 453:110941, 2022), we proposed an approach to learn the gradient of the unclosed high order moment, which performs much better than learning the moment itself and the conventional $P_N$ closure. However, while the ML moment closure has better accuracy, it is not able to guarantee hyperbolicity and has issues with long time stability. In our second paper (Huang et al., in: Machine learning moment closure models for the radiative transfer equation II: enforcing global hyperbolicity in gradient based closures, 2021. arXiv:2105.14410), we identified a symmetrizer which leads to conditions that enforce that the gradient based ML closure is symmetrizable hyperbolic and stable over long time. The limitation of this approach is that in practice the highest moment can only be related to four, or fewer, lower moments. In this paper, we propose a new method to enforce the hyperbolicity of the ML closure model. Motivated by the observation that the coefficient matrix of the closure system is a lower Hessenberg matrix, we relate its eigenvalues to the roots of an associated polynomial. Here, we design two new neural network architectures based on this relation. The ML closure model resulting from the first neural network is weakly hyperbolic and guarantees the physical characteristic speeds, i.e., the eigenvalues are bounded by the speed of light. The second model is strictly hyperbolic and does not guarantee the boundedness of the eigenvalues. Several benchmark tests including the Gaussian source problem and the two-material problem show the good accuracy, stability and generalizability of our hyperbolic ML closure model.

97 MATHEMATICS AND COMPUTING↗

A multi-dimensional, energy- and charge-conserving, nonlinearly implicit, electromagnetic Vlasov–Darwin particle-in-cell algorithm

For decades, the Vlasov–Darwin model has been recognized to be attractive for particle-in-cell (PIC) kinetic plasma simulations in non-radiative electromagnetic regimes, to avoid radiative noise issues and gain computational efficiency. However, the Darwin model results in an elliptic set of field equations that renders conventional explicit time integration unconditionally unstable. We explore a fully implicit PIC algorithm for the Vlasov–Darwin model in multiple dimensions, which overcomes many difficulties of traditional semi-implicit Darwin PIC algorithms. The finite-difference scheme for Darwin field equations and particle equations of motion is space–time-centered, employing particle sub-cycling and orbit-averaging. This algorithm conserves total energy, local charge, canonical-momentum in the ignorable direction, and preserves the Coulomb gauge exactly. An asymptotically well-posed fluid preconditioner allows efficient use of large cell sizes, which are determined by accuracy considerations, not stability, and can be orders of magnitude larger than required in a standard explicit electromagnetic PIC simulation. Finally, we demonstrate the accuracy and efficiency properties of the algorithm with various numerical experiments in 2D–3V.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Adoption of Hypofractionated Whole-Breast Irradiation for Early-Stage Breast Cancer: A National Cancer Data Base Analysis

Purpose: To evaluate the relationship of patient, hospital, and cancer characteristics with the adoption of hypofractionation in a national sample of patients diagnosed with early-stage breast cancer. Methods and Materials: We performed a retrospective study of breast cancer patients in the National Cancer Data Base from 2004-2011 who were treated with radiation therapy and met eligibility criteria for hypofractionation. We used logistic regression to identify factors associated with receipt of hypofractionation (vs conventional fractionation). Results: We identified 13,271 women (11.7%) and 99,996 women (88.3%) with early-stage breast cancer who were treated with hypofractionation and conventional fractionation, respectively. The use of hypofractionation increased significantly, with 5.4% of patients receiving it in 2004 compared with 22.8% in 2011 (P<.001 for trend). Patients living ≥50 miles from the cancer reporting facility had increased odds of receiving hypofractionation (odds ratio 1.57 [95% confidence interval 1.44-1.72], P<.001). Adoption of hypofractionation was associated with treatment at an academic center (P<.001) and living in an area with high median income (P<.001). Hypofractionation was less likely to be used in patients with high-risk disease, such as increased tumor size (P<.001) or poorly differentiated histologic grade (P<.001). Conclusions: The use of hypofractionation is rising and is associated with increased travel distance and treatment at an academic center. Further adoption of hypofractionation may be tempered by both clinical and nonclinical concerns.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Determination of neutron multiplication coefficients for fuel elements irradiated by spallation neutrons

A neutron multiplication coefficient, k{sub eff}, has been estimated for spallation neutron flux using the data of spectrum average cross sections of all absorption, fission, and nonelastic reaction channels of {sup 232}Th, {sup 238}U, {sup 235}U, and {sup 233}U fuel elements. It has been revealed that in spallation neutron flux (i) nonfission, nonabsorption reactions play an important role in the calculation of k{sub eff}, (ii) one can obtain a high value of k{sub eff} even for fertile {sup 232}Th fuel, which is hardly possible in a conventional fast reactor, and (iii) spectrum average absorption cross sections of neutron poisons of a conventional reactor are relatively very small.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Deep residual networks for crystallography trained on synthetic data

The use of artificial intelligence to process diffraction images is challenged by the need to assemble large and precisely designed training data sets. To address this, a codebase called Resonet was developed for synthesizing diffraction data and training residual neural networks on these data. Here, two per-pattern capabilities of Resonet are demonstrated: (i) interpretation of crystal resolution and (ii) identification of overlapping lattices. Resonet was tested across a compilation of diffraction images from synchrotron experiments and X-ray free-electron laser experiments. Crucially, these models readily execute on graphics processing units and can thus significantly outperform conventional algorithms. While Resonet is currently utilized to provide real-time feedback for macromolecular crystallography users at the Stanford Synchrotron Radiation Lightsource, its simple Python-based interface makes it easy to embed in other processing frameworks. This work highlights the utility of physics-based simulation for training deep neural networks and lays the groundwork for the development of additional models to enhance diffraction collection and analysis.

36 MATERIALS SCIENCE↗

Sparse-view proton computed tomography using modulated proton beams

Purpose: Proton imaging that uses a modulated proton beam and an intensity detector allows a relatively fast image acquisition compared to the imaging approach based on a trajectory tracking detector. In addition, it requires a relatively simple implementation in a conventional proton therapy equipment. The model of geometric straight ray assumed in conventional computed tomography (CT) image reconstruction is however challenged by multiple-Coulomb scattering and energy straggling in the proton imaging. Radiation dose to the patient is another important issue that has to be taken care of for practical applications. In this work, the authors have investigated iterative image reconstructions after a deconvolution of the sparsely view-sampled data to address these issues in proton CT. Methods: Proton projection images were acquired using the modulated proton beams and the EBT2 film as an intensity detector. Four electron-density cylinders representing normal soft tissues and bone were used as imaged object and scanned at 40 views that are equally separated over 360°. Digitized film images were converted to water-equivalent thickness by use of an empirically derived conversion curve. For improving the image quality, a deconvolution-based image deblurring with an empirically acquired point spread function was employed. They have implemented iterative image reconstruction algorithms such as adaptive steepest descent-projection onto convex sets (ASD-POCS), superiorization method–projection onto convex sets (SM-POCS), superiorization method–expectation maximization (SM-EM), and expectation maximization-total variation minimization (EM-TV). Performance of the four image reconstruction algorithms was analyzed and compared quantitatively via contrast-to-noise ratio (CNR) and root-mean-square-error (RMSE). Results: Objects of higher electron density have been reconstructed more accurately than those of lower density objects. The bone, for example, has been reconstructed within 1% error. EM-based algorithms produced an increased image noise and RMSE as the iteration reaches about 20, while the POCS-based algorithms showed a monotonic convergence with iterations. The ASD-POCS algorithm outperformed the others in terms of CNR, RMSE, and the accuracy of the reconstructed relative stopping power in the region of lung and soft tissues. Conclusions: The four iterative algorithms, i.e., ASD-POCS, SM-POCS, SM-EM, and EM-TV, have been developed and applied for proton CT image reconstruction. Although it still seems that the images need to be improved for practical applications to the treatment planning, proton CT imaging by use of the modulated beams in sparse-view sampling has demonstrated its feasibility.

60 APPLIED LIFE SCIENCES↗

SU-E-T-532: Left-Sided Breast Cancer Irradiation Using Volumatric Modulated Arc Therapy: An Evaluation of Multiple Commercial Systems

Purposes: There has been growing interest in treating breast cancer using VMAT technique. Our goal is to compare the dosimetry and treatment delivery parameters for the left-sided breast cancer treatment using various VMAT platforms from commercially available planning systems. Methods: Five consecutive left-sided breast cancer patients initially treated with conventional 3D-conformal radiotherapy (3DCRT) were selected. Four VMAT plans using most popular treatment planning systems, including Eclipse (Version 11, Varian), Pinnacle (Version 9.8, Philips), Monaco (Version 2.03, Elekta) and helical Tomotherapy (V4.0, Accuray). The same structure set and same planning goals were used for all VMAT plans. The dosimetric parameters including target coverage and minimum/maximum/mean, dose-volume endpoints for the selected normal structures: the heart, ipsilateral-/contralateral lung and breast, were evaluated. Other dosimetric indices including heterogeneity index (HI) were evaluated. The treatment delivery parameters, such as monitor unit (MUs) and delivery time were also compared. Results: VMAT increases dose homogeneity to the treated volume and reduces the irradiated heart and left-lung volumes. Compared to the 3DCRT technique, all VMAT plans offer better heart and left-lung dose sparing; the mean heart doses were 4.5±1.6(Monaco), 1.2±0.4(Pinnacle), 1.3± (Eclipse) and 5.6±4.4(Tomo), the mean left-lung doses were 5.9±1.5(Monaco), 3.7±0.7(Pinnacle), 1.4± (Eclipse) and 5.2±1.6 (Tomo), while for the 3DCRT plan, the mean heart and left-Lung doses were 2.9±2.0, and 6.8±4.4 (Gy) respectively. The averaged contralateral-breast and lung mean doses were higher in VMAT plans than the 3DCRT plans but were not statistically significant. Among all the VMAT plans, the Pinnacle plans often yield the lowest right-lung/breast mean doses, and slightly better heterogeneity indices that are similar to Tomotherapy plans. Treatment delivery time of the VMAT plans (except helical Tomotherapy IMRT) is estimated to be comparable with the conventional 3DCRT. Conclusion: VMAT achieves equal or better PTV coverage and comparable OARs sparing compared to the conventional 3DCRT techniques.

60 APPLIED LIFE SCIENCES↗

SU-F-T-48: Clinical Implementation of Brachytherapy Planning System for COMS Eye Plaques

Purpose: To commission the Brachytherapy Planning (BP) system (Varian, Palo Alto, CA) for the Collaborative Ocular Melanoma Study (COMS) eye plaques by evaluating dose differences against original plans from Nucletron Planning System (NPS). Methods: NPS system is the primary planning software for COMS-plaques at our facility; however, Brachytherapy Planning 11.0.47 (Varian Medical Systems) is used for secondary check and for seed placement configurations not originally commissioned. Dose comparisons of BP and NPS plans were performed for prescription of 8500 cGy at 5 mm depth and doses to normal structures: opposite retina, inner sclera, macula, optic disk and lens. Plans were calculated for Iodine-125 seeds (OncoSeeds, Model 6711) using COMS-plaques of 10, 12, 14, 16, 18 and 20 mm diameters. An in-house program based on inverse-square was utilized to calculate point doses for comparison as well. Results: The highest dose difference between BP and NPS was 3.7% for the prescription point for all plaques. Doses for BP were higher than doses reported by NPS for all points. The largest percent differences for apex, opposite retina, inner sclera, macula, optic disk, and lens were 3.2%, 0.9%, 13.5%, 20.5%, 15.7% and 2.2%, respectively. The dose calculated by the in-house program was 1.3% higher at the prescription point, and were as high as 42.1%, for points away from the plaque (i.e. opposite retina) when compared to NPS. Conclusion: Doses to the tumor, lens, retina, and optic nerve are paramount for a successful treatment and vision preservation. Both systems are based on TG-43 calculations and assume water medium tissue homogeneity (ρe=1, water medium). Variations seen may result from the different task group versions and/or mathematical algorithms of the software. BP was commissioned to serve as a backup system and it also enables dose calculation in cases where seeds don’t follow conventional placement configuration.

60 APPLIED LIFE SCIENCES↗

Superradiance in the Generalized (Non-Wiener) Dicke Model

It is shown that when nonresonant interactions between atoms and a vacuum electromagnetic field are included in analysis of emission of a localized ensemble of identical atoms, a delay must appear in the cooperative radiation pulse emitted by the atomic ensemble that is initially in a half-excited state. At the same time, the emission of cooperative radiation from a completely excited ensemble for certain parameters must begin without any delay. This contradicts the familiar facts of the conventional Dicke superradiance, in the theory of which nonresonant interactions are disregarded. The model taking into account nonresonant interactions along with other factors of the Dicke model is called the generalized Dicke model.

74 ATOMIC AND MOLECULAR PHYSICS↗

Compact Superconducting RF Accelerators for Water Treatment

Jefferson Lab is actively exploring the environmental applications of compact irradiation facilities utilizing Superconducting Radio Frequency (SRF) accelerator technology ? a well-established technology primarily used in large research machines. Recent advancements, such as the application of thin films of superconducting alloys in radio frequency (RF) resonators and the development of high-capacity cryocoolers, have made it feasible to employ this key technology in compact, standalone irradiation facilities. The main advantage over conventional systems based on normal conducting technology is the significantly enhanced efficiency in beam power generation, enabling exposure to substantially higher radiation doses. In the realm of addressing contaminants in wastewater treatment, particularly concerning persistent substances known as "forever chemicals," this technology presents an attractive solution, given the required considerable effort i.e. dose to break them down. Experiment Numbers:

Vennekate, John↗

The beam test of the lead tungstate calorimeter prototype with SiPM readout at Jefferson Lab

The lead tungstate crystals (PWO4) are a well-known radiator material for precise homogeneous electromagnetic calorimetry. In nuclear physics experiments, the typical way to read out the crystals is using conventional photomultiplier tubes (PMTs). In the case of the presence of a magnetic field, such a method has some complications and requires a passive PMT shielding design. The recent development of Silicon Photomultipliers (SiPMs) with small pixel pitch sizes and relatively small noise levels opens an opportunity avenue to use such a device as an alternative to conventional PMTs. The SiPM readout method may be beneficial for future nuclear physics and collider experiments. We are presenting the beam test results of the calorimeter prototype instrumented with SiPM readout performed at Jefferson Lab. The SiPM readout performance was compared with PMT readout measured at the same experimental conditions. The prototype was successfully tested using beam of photons in the energy range between 3 GeV and 11 GeV in experimental Hall D. The detector performance was also studied using a secondary beam of positrons provided by Hall D pair spectrometer.

Berdnikov, Vladimir↗

As-Run Neutronic Calculations of HFIR Mini-Fuel Experiments: Guidelines for Analysts

This report provides guidelines for analysts performing radiation transport calculations for mini-fuel experiments irradiated in the High Flux Isotope Reactor (HFIR). Procedures, practical recommendations, and modeling conventions which are essential to ensuring consistency and high fidelity in as-run simulations have been compiled. The content is intended to be a portion of the official training material for new staff in this area, offering both technical references and practical guidance derived from previous experience. This report is a living document and will be periodically updated to incorporate new developments, methodological improvements, and lessons learned from ongoing and future irradiation campaigns.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗