Search NASA⌕ Search

SEARCH · Search NASA

Results for “Comparison study”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,189 records · Page 66

Source Levels of In‐Cloud Air in Shallow Cumulus: Consistency Between Paluch Diagram and Lagrangian Particle Tracking

Abstract The Paluch diagram is a widely used tool for interpreting aircraft measurements of shallow cumulus clouds. A prior study conducted by Heus et al. (2008,https://doi.org/10.1175/2008jas2572.1) concluded that the source levels of in‐cloud air inferred from the Paluch diagram exhibit biases, sometimes of several hundred meters, in comparison to those derived from Lagrangian particle tracking. In this short study we revisit this comparison. The results indicate that the upper source levels of in‐cloud air determined from the Lagrangian Particle Tracking and the Paluch diagram are consistent, and the choice of statistical methods is crucial. The significance of this research lies in confirming the reliability of the Paluch analysis, enabling its confident application to aircraft data.

Meteorology & Atmospheric Sciences↗

Cross-Comparative Analysis of GF-1 Wide Field View and Landsat-7 Enhanced Thematic Mapper Plus Data

The wide field view (WFV) sensor on-board GF-1 satellite can acquire multi-spectral data with moderate spatial resolution, which holds great potential for monitoring the Earth's surface. This study assesses WFV data through cross-comparison of spectral band reflectances and vegetation indices with Landsat-7 Enhanced Thematic Mapper plus (ETM+) data. The four vegetation indices considered in this study are the normalized difference vegetation index (NDVI), the enhanced vegetation index (EVI), the ratio vegetation index (RVI), and the soil adjusted vegetation index (SAVI). The R2 between the WFV and ETM+ data were 0.82, 0.89, 0.92, and 0.80 for the blue, green, red, and near-infrared bands reflectance, and 0.90, 0.84, 0.83, and 0.91 for NDVI, EVI, RVI, and SAVI, respectively. The results displayed a high correlation between the spectral reflectances and vegetation indices of the two sensors’ data, which indicated the reliability of the WFV data. Furthermore, the WFV data were better than the ETM+ data with regards to spatial and temporal resolutions.

42 ENGINEERING↗

WE-G-BRE-06: New Potential for Enhancing External Beam Radiotherapy for Lung Cancer Using FDA-Approved Concentrations of Cisplatin Or Carboplatin Nanoparticles Administered Via Inhalation

Purpose: This study investigates, for the first time, the dose enhancement to lung tumors due to cisplatin nanoparticles (CNPs) and carboplatin nanoparticles (CBNPs) administered via inhalation route (IR) during external beam radiotherapy. Methods: Using Monte Carlo generated 6 MV energy fluence spectra, a previously employed analytic method was used to estimate dose enhancement to lung tumor due to radiation-induced photoelectrons from CNPs administered via IR in comparison to intravenous (IV) administration. Previous studies have indicated about 5% of FDA-approved cisplatin concentrations reach the lung tumor via IV. Meanwhile recent experimental studies indicate that 3.5–14.6 times higher concentrations of CNPs can reach the lung tumors by IR compared to IV. Taking these into account, the dose enhancement factor (DEF) defined as the ratio of the dose with and without CNPs was calculated for field size of 10 cm × 10 cm (sweeping gap), for a range of tumor depths and tumor sizes. Similar calculations were done for CBNPs. Results: For IR with 3.5 times higher concentrations than IV, and 2 cm diameter tumor, clinically significant DEF values of 1.19–1.30 were obtained for CNPs at 3–10 cm depth, respectively, in comparison to 1.06–1.09 for IV. For CBNPs, DEF values of 1.26–1.41 were obtained in comparison to 1.07–1.12 for IV. For IR with 14.6 times higher concentrations, higher DEF values were obtained e.g. 1.81–2.27 for CNPs. DEF increased with increasing field size or decreasing tumor size. Conclusions: Our preliminary results indicate that major dose enhancement to lung tumors can be achieved using CNPs/CBNPs administered via IR, in contrast to IV administration during external beam radiotherapy. These findings highlight a potential new approach for radiation boosting to lung tumors using CNPs/CBNPs administered via IR. This would, especially, be applicable during concomitant chemoradiotherapy, potentially allowing for dose enhancement while minimizing normal tissue toxicities.

60 APPLIED LIFE SCIENCES↗

THE ANGULAR MOMENTUM OF MAGNETIZED MOLECULAR CLOUD CORES: A TWO-DIMENSIONAL-THREE-DIMENSIONAL COMPARISON

In this work, we present a detailed study of the rotational properties of magnetized and self-gravitating dense molecular cloud (MC) cores formed in a set of two very high resolution three-dimensional (3D) MC simulations with decaying turbulence. The simulations have been performed using the adaptative mesh refinement code RAMSES with an effective resolution of 4096{sup 3} grid cells. One simulation represents a mildly magnetically supercritical cloud and the other a strongly magnetically supercritical cloud. We identify dense cores at a number of selected epochs in the simulations at two density thresholds which roughly mimic the excitation densities of the NH{sub 3} (J - K) = (1,1) transition and the N{sub 2}H{sup +} (1-0) emission line. A noticeable global difference between the two simulations is the core formation efficiency (CFE) of the high-density cores. In the strongly supercritical simulations, the CFE is 33% per unit free-fall time of the cloud (t{sub ff,cl}), whereas in the mildly supercritical simulations this value goes down to {approx}6 per unit t{sub ff,cl}. A comparison of the intrinsic specific angular momentum (j{sub 3D}) distributions of the cores with the specific angular momentum derived using synthetic two-dimensional (2D) velocity maps of the cores (j{sub 2D}) shows that the synthetic observations tend to overestimate the true value of the specific angular momentum by a factor of {approx}8-10. We find that the distribution of the ratio j{sub 3D}/j{sub 2D} of the cores peaks at around {approx}0.1. The origin of this discrepancy lies in the fact that contrary to the intrinsic determination of j which sums up the individual gas parcels' contributions to the angular momentum, the determination of the specific angular momentum using the standard observational procedure which is based on a measurement on the global velocity gradient under the hypothesis of uniform rotation smoothes out the complex fluctuations present in the 3D velocity field. Our results may well provide a natural explanation for the discrepancy by a factor of {approx}10 observed between the intrinsic 3D distributions of the specific angular momentum and the corresponding distributions derived in real observations. We suggest that previous and future measurements of the specific angular momentum of dense cores which are based on the measurement of the observed global velocity gradients may need to be reduced by a factor of {approx}10 in order to derive a more accurate estimate of the true specific angular momentum in the cores. We also show that the exponent of the size-specific angular momentum relation is smaller ({approx}1.4) in the synthetic observations than their values derived in the 3D space ({approx}1.8).

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Development of a mobile toolmark characterization/comparison system [Development of a mobile, automated toolmark characterization/comparison system]

Since the development of the striagraph, various attempts have been made to enhance forensic investigation through the use of measuring and imaging equipment. This study describes the development of a prototype system employing an easy-to-use software interface designed to provide forensic examiners with the ability to measure topography of a toolmarked surface and then conduct various comparisons using a statistical algorithm. Acquisition of the data is carried out using a portable 3D optical profilometer, and comparison of the resulting data files is made using software named “MANTIS” (Mark and Tool Inspection Suite). The system has been tested on laboratory-produced markings that include fully striated marks (e.g., screwdriver markings), quasistriated markings produced by shear-cut pliers, impression marks left by chisels, rifling marks on bullets, and cut marks produced by knives. Using the system, an examiner has the potential to (i) visually compare two toolmarked surfaces in a manner similar to a comparison microscope and (ii) use the quantitative information embedded within the acquired data to obtain an objective statistical comparison of the data files. Finally, this study shows that, based on the results from laboratory samples, the system has great potential for aiding examiners in conducting comparisons of toolmarks.

47 OTHER INSTRUMENTATION↗

Economic Analyses in Squamous Cell Carcinoma of the Head and Neck: A Review of the Literature From a Clinical Perspective

The purpose of this review was to describe cost-effectiveness and cost analysis studies across treatment modalities for squamous cell carcinoma of the head and neck (SCCHN), while placing their results in context of the current clinical practice. We performed a literature search in PubMed for English-language studies addressing economic analyses of treatment modalities for SCCHN published from January 2000 to March 2013. We also performed an additional search for related studies published by the National Institute for Health and Clinical Excellence in the United Kingdom. Identified articles were classified into 3 clinical approaches (organ preservation, radiation therapy modalities, and chemotherapy regimens) and into 2 types of economic studies (cost analysis and cost-effectiveness/cost-utility studies). All cost estimates were normalized to US dollars, year 2013 values. Our search yielded 23 articles: 13 related to organ preservation approaches, 5 to radiation therapy modalities, and 5 to chemotherapy regimens. In general, studies analyzed different questions and modalities, making it difficult to reach a conclusion. Even when restricted to comparisons of modalities within the same clinical approach, studies often yielded conflicting findings. The heterogeneity across economic studies of SCCHN should be carefully understood in light of the modeling assumptions and limitations of each study and placed in context with relevant settings of clinical practices and study perspectives. Furthermore, the scarcity of comparative effectiveness and quality-of-life data poses unique challenges for conducting economic analyses for a resource-intensive disease, such as SCCHN, that requires a multimodal care. Future research is needed to better understand how to compare the costs and cost-effectiveness of different modalities for SCCHN.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

WE-G-204-08: Optimized Digital Radiographic Technique for Lost Surgical Devices/Needle Identification

Purpose: Small surgical devices and needles are used in many surgical procedures. Conventionally, an x-ray film is taken to identify missing devices/needles if post procedure count is incorrect. There is no data to indicate smallest surgical devices/needles that can be identified with digital radiography (DR), and its optimized acquisition technique. Methods: In this study, the DR equipment used is a Canon RadPro mobile with CXDI-70c wireless DR plate, and the same DR plate on a fixed Siemens Multix unit. Small surgical devices and needles tested include Rubber Shod, Bulldog, Fogarty Hydrogrip, and needles with sizes 3-0 C-T1 through 8-0 BV175-6. They are imaged with PMMA block phantoms with thickness of 2–8 inch, and an abdomen phantom. Various DR techniques are used. Images are reviewed on the portable x-ray acquisition display, a clinical workstation, and a diagnostic workstation. Results: all small surgical devices and needles are visible in portable DR images with 2–8 inch of PMMA. However, when they are imaged with the abdomen phantom plus 2 inch of PMMA, needles smaller than 9.3 mm length can not be visualized at the optimized technique of 81 kV and 16 mAs. There is no significant difference in visualization with various techniques, or between mobile and fixed radiography unit. However, there is noticeable difference in visualizing the smallest needle on a diagnostic reading workstation compared to the acquisition display on a portable x-ray unit. Conclusion: DR images should be reviewed on a diagnostic reading workstation. Using optimized DR techniques, the smallest needle that can be identified on all phantom studies is 9.3 mm. Sample DR images of various small surgical devices/needles available on diagnostic workstation for comparison may improve their identification. Further in vivo study is needed to confirm the optimized digital radiography technique for identification of lost small surgical devices and needles.

60 APPLIED LIFE SCIENCES↗

Behind-the-Meter Solar + Storage Modeling Tool Comparison

Several techno-economic models exist to evaluate solar PV plus battery storage opportunities for behind-the-meter, commercial application. This tool comparison evaluates the methodological differences between several solar plus storage modeling tools and employs a case study to compare their outputs. The tools selected for comparison include NREL's REopt Lite, NREL's System Advisor Model (SAM), Homer Energy's Homer Grid, Geli ESyst, EPRI StorageVET, and LBL's DER-CAM. The comparison focuses on each tool's simulation and optimization capabilities, PV and battery performance modeling, dispatch strategies, and economic model assumptions and calculations, with brief mention of additional capabilities outside the scope of behind-the-meter PV and battery storage. This report describes the case study's tool inputs and outputs and dives into the differences in assumptions, methodologies, and capabilities between tools.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Clinical evaluation of a medical high dynamic range display

Purpose: Recent new medical displays do have higher contrast and higher luminance but do not have a High Dynamic Range (HDR). HDR implies a minimum luminance value close to zero. A medical HDR display prototype based on two Liquid Crystal layers has been developed. The goal of this study is to evaluate the potential clinical benefit of such display in comparison with a low dynamic range (LDR) display. Methods: The study evaluated the clinical performance of the displays in a search and detection task. Eight radiologists read chest x-ray images some of which contained simulated lung nodules. The study used a JAFROC (Jacknife Free Receiver Operating Characteristic) approach for analyzing FROC data. The calculated figure of merit (FoM) is the probability that a lesion is rated higher than all rated nonlesions on all images. Time per case and accuracy for locating the center of the nodules were also compared. The nodules were simulated using Samei’s model. 214 CR and DR images [half were “healthy images” (chest nodule-free) and half “diseased images”] were used resulting in a total number of nodules equal to 199 with 25 images with 1 nodule, 51 images with 2 nodules, and 24 images with 3 nodules. A dedicated software interface was designed for visualizing the images for each session. For the JAFROC1 statistical analysis, the study is done per nodule category: all nodules, difficult nodules, and very difficult nodules. Results: For all nodules, the averaged FoM{sub HDR} is slightly higher than FoM{sub LDR} with 0.09% of difference. For the difficult nodules, the averaged FoM{sub HDR} is slightly higher than FoM{sub LDR} with 1.38% of difference. The averaged FoM{sub HDR} is slightly higher than FoM{sub LDR} with 0.71% of difference. For the true positive fraction (TPF), both displays (the HDR and the LDR ones) have similar TPF for all nodules, but looking at difficult and very difficult nodules, there are more TP for the HDR display. The true positive fraction has been also computed in function of the local average luminance around the nodules. For the lowest luminance range, there is more than 30% in favor of the HDR display. For the highest luminance range, there is less than 6% in favor of the LDR display. Conclusions: This study shows the potential benefit of using a HDR display in radiology.

60 APPLIED LIFE SCIENCES↗

Lattice location study of implanted In in Ge

We report on emission channeling experiments to determine the lattice location and the thermal stability of implanted {sup 111}In atoms in Ge. The majority of the In atoms was found on the substitutional site, which is a thermally stable site at least up to 500 deg. C. We also found strong indication that directly after implantation, a fraction of the implanted {sup 111}In atoms occupies the bond-centered (BC) site. This fraction disappears after annealing at 300 deg. C. From comparison with ab initio calculations, electrical studies, and perturbed angular correlation experiments, the In atoms on the BC site can be related to In-vacancy and In-self-interstitial defect complexes. The activation energy for dissociation of this BC related defect was found to be below 1.6 eV.

36 MATERIALS SCIENCE↗

One-step hydrothermal synthesis and electrochemical performance of sodium-manganese-iron phosphate as cathode material for Li-ion batteries

The sodium-manganese-iron phosphate Na{sub 2}Mn{sub 1.5}Fe{sub 1.5}(PO{sub 4}){sub 3} (NMFP) with alluaudite structure was obtained by a one-step hydrothermal synthesis route. The physical properties and structure of this material were obtained through XRD and Mössbauer analyses. X-ray diffraction Rietveld refinements confirm a cationic distribution of Na{sup +} and presence of vacancies in A(2)’, Na{sup +} and small amounts of Mn{sup 2+} in A(1), Mn{sup 2+} in M(1), 0.5 Mn{sup 2+} and Fe cations (Mn{sup 2+},Fe{sup 2+} and Fe{sup 3+}) in M(2), leading to the structural formula Na{sub 2}Mn(Mn{sub 0.5}Fe{sub 1.5})(PO{sub 4}){sub 3}. The particles morphology was investigated by SEM. Several reactions with different hydrothermal reaction times were attempted to design a suitable synthesis protocol of NMFP compound. The time of reaction was varied from 6 to 48 h at 220 °C. The pure phase of NMFP particles was firstly obtained when the hydrothermal reaction of NMFP precursors mixture was maintained at 220 °C for 6 h. When the reaction time was increased from 6 to 12, 24 and 48 h, the dandelion structure was destroyed in favor of NMFP micro-rods. The combination of NMFP (NMFP-6H, NMFP-12H, NMFP-24H and NMFP-48H) structure refinement and Mössbauer characterizations shows that the increase of the reaction time leads to the progressive increment of Fe(III) and the decrease of the crystal size. The electrochemical tests indicated that NMFP is a 3 V sodium intercalating cathode. The comparison of the discharge capacity evolution of studied NMFP electrode materials at C/5 current density shows different capacities of 48, 40, 34 and 34 mA h g{sup −1} for NMFP-6H, NMFP-12H, NMFP-24H and NMFP-48H respectively. Interestingly, all samples show excellent capacity retention of about 99% during 50 cycles. - Graphical abstract: SEM micrographs (left) and evolution of the discharge on cycling with increasing rates from C/15 to 4 C (right) of NMFP material prepared by hydrothermal synthesis at 220 °C at indicated time. Display Omitted - Highlights: • One-step hydrothermal method was used to prepare sodium manganese iron phosphate NMFP. • 3D-NMFP dandelion sphere-like particles were obtained at 220 °C after 6 h. • Increasing reaction time leads to the enhancement of the crystallinity and crystal stabilility of NMFP. • The growth of the particle size and change of morphology are correlated to the reaction time. • EC performance of NMFP powders were greatly affected by the synthesis conditions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A Comparison of Forecast Error Generators for Modeling Wind and Load Uncertainty

This paper presents four algorithms to generate random forecast error time series, including a truncated-normal distribution model, a state-space based Markov model, a seasonal autoregressive moving average (ARMA) model, and a stochastic-optimization based model. The error time series are used to create real-time (RT), hour-ahead (HA), and day-ahead (DA) wind and load forecast time series that statistically match historically observed forecasting data sets, used for variable generation integration studies. A comparison is made using historical DA load forecast and actual load values to generate new sets of DA forecasts with similar stoical forecast error characteristics. This paper discusses and compares the capabilities of each algorithm to preserve the characteristics of the historical forecast data sets.

Lu, Ning↗

An experimental comparison of triggered and random pulse train uncertainties

In this paper we present an experimental comparison of signal-triggered and randomly triggered based analysis algorithms of neutron multiplicity data. Traditional shift register type signal-triggered multiplicity analysis of singles, doubles and triples rates is compared with analysis using randomly triggered gates. Two methods of random gate generation are explored - non-overlapping gates (Feyrunan approach) and periodic overlapping gates (fast accidentals). Using californium sources with low, medium and high rate in combination with AmLi sources (as a surrogate for plutonium) we investigate relative standard deviation (RSD) of data in order to determine if there are parameter spaces in which one of the measurement methods should be preferred. Neutron correlation analysis is a commonly used NDA technique to assay plutonium mass. The data can be collected in two distinct ways: using signal-triggered or randomly triggered counting gates. Analysis algorithms were developed for both approaches to determine singles (S), doubles (D) and triples (7) rates from the measured sample. Currently the most commonly implemented technique to collect neutron coincidence data utilizes shift register based electronics. Shift register uses signal-triggered counting gates to generate foreground multiplicity distribution of correlated+accidental events and a random gate (opened after a predefined long delay following the signal trigger) to generate background multiplicity distribution of accidental events. Modern shift registers include fast accidental option to sample data with a fixed clock frequency. This way a set of overlapping gates is used to generate background multiplicity distributions in order to improve the measurement precision. In parallel to shift register approach the Feynman variance technique is frequently used, which utilizes set of consecutive non-overlapping gates. In general, different user communities (e.g. safeguards, nuclear material accountancy, emergency response) have used only one of the two analysis methods for the nuclear material assay. The aim of this study is to provide a systematic comparison of the precision of the measured S, D, T rates and {sup 240}Pu effective mass obtained using the above mentioned pulse train sampling techniques. In order to perform this task, a LANL developed list mode based data acquisition system is used, where the entire pulse train is recorded and subsequently analyzed. The list mode acquisition brings an essential advantage for this type of comparison, since the very same pulse train can be analyzed using signal-triggered as well as randomly triggered counting gates. The aim of this study is not only to compare the precision of signal-triggered versus random triggered sampling techniques, but also to investigate the influence of fast accidental sampling on the precision of signal-triggered results. In addition the different random sampling techniques used in safeguards are investigated. For this purpose we implement two types of random sampling - non-overlapping gates (Feynrnan approach) and periodic overlapping gates (fast accidentals). In the following sections the equations utilized in the pulse train analysis are described, experimental setup and measurement techniques are discussed and finally the results are summarized and discussed.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

On the mid-infrared variability of candidate eruptive variables (exors): A comparison between Spitzer and WISE data

Aiming to statistically study the variability in the mid-IR of young stellar objects, we have compared the 3.6, 4.5, and 24 μm Spitzer fluxes of 1478 sources belonging to the C2D (Cores to Disks) legacy program with the WISE fluxes at 3.4, 4.6, and 22 μm. From this comparison, we have selected a robust sample of 34 variable sources. Their variations were classified per spectral Class (according to the widely accepted scheme of Class I/flat/II/III protostars), and per star forming region. On average, the number of variable sources decreases with increasing Class and is definitely higher in Perseus and Ophiuchus than in Chamaeleon and Lupus. According to the paradigm Class ≡ Evolution, the photometric variability can be considered to be a feature more pronounced in less evolved protostars, and, as such, related to accretion processes. Moreover, our statistical findings agree with the current knowledge of star formation activity in different regions. The 34 selected variables were further investigated for similarities with known young eruptive variables, namely the EXors. In particular, we analyzed (1) the shape of the spectral energy distribution, (2) the IR excess over the stellar photosphere, (3) magnitude versus color variations, and (4) output parameters of model fitting. This first systematic search for EXors ends up with 11 bona fide candidates that can be considered as suitable targets for monitoring or future investigations.

79 ASTRONOMY AND ASTROPHYSICS↗

Stochastic Optimization and Uncertainty Quantification of Natrium-based Nuclear-Renewable Energy Systems for Flexible Power Applications in Deregulated Markets

Rapid integration of variable renewable energy sources (VRES) has made modeling and stochastic optimization of hybrid energy systems crucial for studying their long-term performance and viability. However, most studies have focused on just historical data, which may be unreliable for capturing short-term fluctuations, rare events, and long-term patterns of energy demand, price, and the variability of renewable energy sources. For this study, optimal synthetic time series models were developed using Wasserstein distance. The models were validated by comparing the key statistical measures against those of the historical data. They were then used to optimize the integrated Natrium-style advanced energy systems and their long-term (30 years) economics. The stochastic model performs bi-level optimization to find the optimal sizes for the balance of plant and thermal energy storage, while also optimizing energy dispatch to achieve the maximum net present value. In studies of two deregulated markets (California ISO and the Electric Reliability Council of Texas), the integrated Natrium-style system performed better in CAISO than in ERCOT, given higher and more consistent electricity prices during peak-demand periods. The potentially enlarged cost associated with the variable operation and maintenance of the TES system also plays a significant role in driving the system sizing, thus its impacts on the system are investigated in detail through comparison against a baseline case. The study also finds that the bi-level optimization results based on stochastic gradient descent closely match the grid search results. The uncertainty quantification of the stochastic signals provides further NPV-related insights and probability distributions for the case studies. The normal standard error of the mean of NPV for the case with and without TES VOM for CAISO were found to be 7.73M (plus-minus sign) 1.09M USD and 104.99M (plus-minus sign) 1.25M USD, respectively based on a 95% confidence. Given the relatively small NPV variance based on 150 samples, the analysis affords the most robust possible prediction of the techno-economic performance of the integrated Natrium-style energy systems.

25 ENERGY STORAGE↗

TEMPERATURE AND DENSITY DISTRIBUTION IN THE MOLECULAR GAS TOWARD WESTERLUND 2: FURTHER EVIDENCE FOR PHYSICAL ASSOCIATION

Furukawa et al. reported the existence of a large mass of molecular gas associated with the super star cluster Westerlund 2 and the surrounding H II region RCW49, based on a strong morphological correspondence between NANTEN2 {sup 12}CO(J = 2-1) emission and Spitzer IRAC images of the H II region. We here present temperature and density distributions in the associated molecular gas at approx3.5 pc resolution, as derived from a large velocity gradient analysis of the {sup 12}CO(J = 2-1), {sup 12}CO(J = 1-0), and {sup 13}CO(J = 2-1) transitions. The kinetic temperature is as high as approx60-150 K within a projected distance of approx5-10 pc from Westerlund 2 and decreases to as low as approx10 K away from the cluster. The high temperature provides robust verification that the molecular gas is indeed physically associated with the H II region, supporting Furukawa et al.'s conclusion. The derived temperature is also roughly consistent with theoretical calculations of photodissociation regions (PDRs), while the low spatial resolution of the present study does not warrant a more detailed comparison with PDR models. We suggest that the molecular clouds presented here will serve as an ideal laboratory to test theories on PDRs in future higher resolution studies.

79 ASTRONOMY AND ASTROPHYSICS↗

Organ doses for reference pediatric and adolescent patients undergoing computed tomography estimated by Monte Carlo simulation

Purpose: To establish an organ dose database for pediatric and adolescent reference individuals undergoing computed tomography (CT) examinations by using Monte Carlo simulation. The data will permit rapid estimates of organ and effective doses for patients of different age, gender, examination type, and CT scanner model. Methods: The Monte Carlo simulation model of a Siemens Sensation 16 CT scanner previously published was employed as a base CT scanner model. A set of absorbed doses for 33 organs/tissues normalized to the product of 100 mAs and CTDI{sub vol} (mGy/100 mAs mGy) was established by coupling the CT scanner model with age-dependent reference pediatric hybrid phantoms. A series of single axial scans from the top of head to the feet of the phantoms was performed at a slice thickness of 10 mm, and at tube potentials of 80, 100, and 120 kVp. Using the established CTDI{sub vol}- and 100 mAs-normalized dose matrix, organ doses for different pediatric phantoms undergoing head, chest, abdomen-pelvis, and chest-abdomen-pelvis (CAP) scans with the Siemens Sensation 16 scanner were estimated and analyzed. The results were then compared with the values obtained from three independent published methods: CT-Expo software, organ dose for abdominal CT scan derived empirically from patient abdominal circumference, and effective dose per dose-length product (DLP). Results: Organ and effective doses were calculated and normalized to 100 mAs and CTDI{sub vol} for different CT examinations. At the same technical setting, dose to the organs, which were entirely included in the CT beam coverage, were higher by from 40 to 80% for newborn phantoms compared to those of 15-year phantoms. An increase of tube potential from 80 to 120 kVp resulted in 2.5-2.9-fold greater brain dose for head scans. The results from this study were compared with three different published studies and/or techniques. First, organ doses were compared to those given by CT-Expo which revealed dose differences up to several-fold when organs were partially included in the scan coverage. Second, selected organ doses from our calculations agreed to within 20% of values derived from empirical formulae based upon measured patient abdominal circumference. Third, the existing DLP-to-effective dose conversion coefficients tended to be smaller than values given in the present study for all examinations except head scans. Conclusions: A comprehensive organ/effective dose database was established to readily calculate doses for given patients undergoing different CT examinations. The comparisons of our results with the existing studies highlight that use of hybrid phantoms with realistic anatomy is important to improve the accuracy of CT organ dosimetry. The comprehensive pediatric dose data developed here are the first organ-specific pediatric CT scan database based on the realistic pediatric hybrid phantoms which are compliant with the reference data from the International Commission on Radiological Protection (ICRP). The organ dose database is being coupled with an adult organ dose database recently published as part of the development of a user-friendly computer program enabling rapid estimates of organ and effective dose doses for patients of any age, gender, examination types, and CT scanner model.

61 RADIATION PROTECTION AND DOSIMETRY↗

Note: Strain sensitivity comparison between fiber Bragg gratings inscribed on 125 and 80 micron cladding diameter fibers, case study on the solidification monitoring of a photo-curable resin

The influence of fiber Bragg grating diameter when measuring strain is investigated and quantified. Two fiber Bragg gratings with bare cladding diameter of 125 μm and 80 μm are produced by excimer laser irradiation through a phase mask, and are used to simultaneously monitor the Bragg wavelength shift due to the strain produced by the solidification of a photo-curable resin during light exposure. It is found that the ratio of the measured strains in the two fiber Bragg gratings is close to the inverse ratio of the fiber’s cladding diameter. These results represent a direct simultaneous comparison between 125 μm and 80 μm diameter fiber Bragg grating strain sensors, and demonstrate the feasibility of strain measurements in photo-curable resins using bare 80 μm cladding diameter fiber Bragg gratings with an increased sensitivity and spatial resolution compared with standard 125 μm diameter fiber Bragg gratings.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗