Search NASA⌕ Search

SEARCH · Search NASA

Results for “Computer Programming and Software”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,189 records · Page 66

A mass graph-based approach for the identification of modified proteoforms using top-down tandem mass spectra

Motivation: Although proteomics has rapidly developed in the past decade, researchers are still in the early stage of exploring the world of complex proteoforms, which are protein products with various primary structure alterations resulting from gene mutations, alternative splicing, post-translational modifications, and other biological processes. Proteoform identification is essential to mapping proteoforms to their biological functions as well as discovering novel proteoforms and new protein functions. Top-down mass spectrometry is the method of choice for identifying complex proteoforms because it provides a “bird’s eye view” of intact proteoforms. The combinatorial explosion of various alterations on a protein may result in billions of possible proteoforms, making proteoform identification a challenging computational problem. Results: We propose a new data structure, called the mass graph, for efficient representation of proteoforms and design mass graph alignment algorithms. We developed TopMG, a mass graph-based software tool for proteoform identification by top-down mass spectrometry. Experiments on top-down mass spectrometry data sets showed that TopMG outperformed existing methods in identifying complex proteoforms.

Dynamic Programming↗

Safety Requirement Management System (SRMS) - Improved Documented Safety Analyses Implementation - 18476

Savannah River Remediation (SRR) developed a new software application, Safety Requirement Management System (SRMS), to improve Documented Safety Analysis (DSA) safety requirement implementation in the Savannah River Site's Liquid Waste facilities. Technical Safety Requirement (TSR) Limited Conditions of Operations (LCOs) and related surveillances were previously tracked using four different applications. Due to their differences and their age, the applications introduced a number of operational challenges and vulnerabilities, including outdated platforms, usage demands beyond original design, and different organizational work processes. SRMS was developed to resolve these issues by using a single web-based approach that provides consistency, wider accessibility, simpler maintenance, and a platform for additional functionality. Other SRS facilities are evaluating the application for its applicability as a standard practice across the site. The new SRMS application decreased the administrative overhead for application maintenance, provided the needed TSR change management functionality, and reduced error precursors with the following advantages: - Consistent process/application across all SRR facilities - More efficient way to track and communicate compliance with DSA time-related requirements (i.e., TSR LCOs and surveillances). - Web-based search capability for LCO entries/exits and a record of surveillance performances. - TSR change management and independent reviews through electronic approvals. For example, the application provides the ability to bundle and stage LCO and surveillance changes associated with a TSR revision. The approval process involves multiple roles from the facility to ensure validity. - Formal configuration management program, fully supported by software life cycle documents. SRMS was implemented at Defense Waste Processing Facility (DWPF) in June 2017, with implementation in all Liquid Waste facilities expected by the end of 2017. Next, SRR plans to expand SRMS functionality to include a linking document database (LDD) to support the DSA requirements. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

IBEX: An open infrastructure software platform to facilitate collaborative work in radiomics

Purpose: Radiomics, which is the high-throughput extraction and analysis of quantitative image features, has been shown to have considerable potential to quantify the tumor phenotype. However, at present, a lack of software infrastructure has impeded the development of radiomics and its applications. Therefore, the authors developed the imaging biomarker explorer (IBEX), an open infrastructure software platform that flexibly supports common radiomics workflow tasks such as multimodality image data import and review, development of feature extraction algorithms, model validation, and consistent data sharing among multiple institutions. Methods: The IBEX software package was developed using the MATLAB and C/C++ programming languages. The software architecture deploys the modern model-view-controller, unit testing, and function handle programming concepts to isolate each quantitative imaging analysis task, to validate if their relevant data and algorithms are fit for use, and to plug in new modules. On one hand, IBEX is self-contained and ready to use: it has implemented common data importers, common image filters, and common feature extraction algorithms. On the other hand, IBEX provides an integrated development environment on top of MATLAB and C/C++, so users are not limited to its built-in functions. In the IBEX developer studio, users can plug in, debug, and test new algorithms, extending IBEX’s functionality. IBEX also supports quality assurance for data and feature algorithms: image data, regions of interest, and feature algorithm-related data can be reviewed, validated, and/or modified. More importantly, two key elements in collaborative workflows, the consistency of data sharing and the reproducibility of calculation result, are embedded in the IBEX workflow: image data, feature algorithms, and model validation including newly developed ones from different users can be easily and consistently shared so that results can be more easily reproduced between institutions. Results: Researchers with a variety of technical skill levels, including radiation oncologists, physicists, and computer scientists, have found the IBEX software to be intuitive, powerful, and easy to use. IBEX can be run at any computer with the windows operating system and 1GB RAM. The authors fully validated the implementation of all importers, preprocessing algorithms, and feature extraction algorithms. Windows version 1.0 beta of stand-alone IBEX and IBEX’s source code can be downloaded. Conclusions: The authors successfully implemented IBEX, an open infrastructure software platform that streamlines common radiomics workflow tasks. Its transparency, flexibility, and portability can greatly accelerate the pace of radiomics research and pave the way toward successful clinical translation.

60 APPLIED LIFE SCIENCES↗

Introduction to Phenix

PHENIX is a software package that automates nearly all aspects of macromolecular structure determination. This talk will describe the main features of PHENIX, including automated structure solution by MIR, MAD and SAD methods, refinement, molecular replacement, and validation. The PHENIX GUI and command line interfaces will be described as well.

59 BASIC BIOLOGICAL SCIENCES↗

Generic Optimization Program User Manual Version 3.0.0

GenOpt is an optimization program for the minimization of a cost function that is evaluated by an external simulation program. It has been developed for optimization problems where the cost function is computationally expensive and its derivatives are not available or may not even exist. GenOpt can be coupled to any simulation program that reads its input from text files and writes its output to text files. The independent variables can be continuous variables (possibly with lower and upper bounds), discrete variables, or both, continuous and discrete variables. Constraints on dependent variables can be implemented using penalty or barrier functions. GenOpt uses parallel computing to evaluate the simulations. GenOpt has a library with local and global multi-dimensional and one-dimensional optimization algorithms, and algorithms for doing parametric runs. An algorithm interface allows adding new minimization algorithms without knowing the details of the program structure. GenOpt is written in Java so that it is platform independent. The platform independence and the general interface make GenOpt applicable to a wide range of optimization problems. GenOpt has not been designed for linear programming problems, quadratic programming problems, and problems where the gradient of the cost function is available. For such problems, as well as for other problems, special tailored software exists that is more efficient.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Lustre on Red Sky.

The goals of Lustre on Red Sky are: (1) provide home/projects/scratch Lustre file systems; (2) adhere to the Sun HPC stack; (3) implement software RAID on Sun provided JBODs; and (4) design for easy administration. Conclusions are: (1) software RAID includes additional risks and administration vs. hardware RAID solutions; (2) limited testing of hardware in these configurations make it ill-suited for rapid deployment in a production environment; and (3) Lustre has been a shining star on this machine, Red Sky users are pleased with its performance.

99 GENERAL AND MISCELLANEOUS↗

Analyzing the Energy and Power Consumption of Remote Memory Accesses in the OpenSHMEM Model

PGAS models like OpenSHMEM provide interfaces to explicitly initiate one-sided remote memory accesses among processes. In addition, the model also provides synchronizing barriers to ensure a consistent view of the distributed memory at different phases of an application. The incorrect use of such interfaces affects the scalability achievable while using a parallel programming model. This study aims at understanding the effects of these constructs on the energy and power consumption behavior of OpenSHMEM applications. Our experiments show that cost incurred in terms of the total energy and power consumed depends on multiple factors across the software and hardware stack. We conclude that there is a significant impact on the power consumed by the CPU and DRAM due to multiple factors including the design of the data transfer patterns within an application, the design of the communication protocols within a middleware, the architectural constraints laid by the interconnect solutions, and also the levels of memory hierarchy within a compute node. This work motivates treating energy and power consumption as important factors while designing compute solutions for current and future distributed systems.

Jana, Siddhartha↗

The ATLAS experiment software on ARM

With an increased dataset obtained during the Run 3 of the LHC at CERN and the even larger expected increase of the dataset by more than one order of magnitude for the HL-LHC, the ATLAS experiment is reaching the limits of the current data processing model in terms of traditional CPU resources based on x86_64 architectures and an extensive program for software upgrades towards the HL-LHC has been set up. The ARM architecture is becoming a competitive and energy efficient alternative. Some surveys indicate its increased presence in HPCs and commercial clouds, and some WLCG sites have expressed their interest. Chip makers are also developing their next generation solutions on ARM architectures, sometimes combining ARM and GPU processors in the same chip. Consequently it is important that the ATLAS software embraces the change and is able to successfully exploit this architecture. We report on the successful porting to ARM of the Athena software framework, which is used by ATLAS for both online and offline computing operations. Furthermore we report on the successful validation of simulation workflows running on ARM resources. For this we have set up an ATLAS Grid site using ARM compatible middleware and containers on Amazon Web Services (AWS) ARM resources. The ARM version of Athena is fully integrated in the regular software build system and distributed in the same way as other software releases. In addition, the workflows have been integrated into the HEPscore benchmark suite which is the planned WLCG wide replacement of the HepSpec06 benchmark used for Grid site pledges. In the overall porting process we have used resources on AWS, Google Cloud Platform (GCP) and CERN. A performance comparison of different architectures and resources will be discussed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

SU-E-T-235: Data Mining for Evaluating Treatment Performances Over a Large Quantity of Data to Monitor and Improve SBRT Workflow

Purpose: To quality assure a large quantity of retrospective treatment cases for treatment performances by randomly sampling is inefficient. Here we provide a method to efficiently monitor and investigate the QA of SBRT workflow over Mosaiq. Methods: The code developed with Microsoft SQL Server Management Studio 2008R2 and VBA was used for retrieving and sorting data from Mosaiq (version 2.3–2.6 during 2012–2015). SBRT patients were filtered by fractional dose over 350cGy and total fraction number less than 6, which SBRT prescriptions were defined. The quality assurance on the SBRT workflow was focused on the treatment deliveries such as patient positioning setup, CBCT indicated offsets and couch shifted corrections. The treatment delivery were done by Varian Truebeam systems and the record/verify by Mosaiq. Results: Total 82 SBRT patients corresponding to 103 courses and 854 CBCT images were found by the retrieval query. Most centers record daily pre-treatment (Pre-Tx: before treatment shift) image-guided shifts along treatment course for inter-fraction motion record, and it is useful to also verify it with post-treatment imaging (Post-Tx: after treatment CBCT verification) to verify intra-fraction motion. Analyzing the details of daily recorded shifts can reveals the information of patient-setup and staff’s record/verify behaviors. 3 examples were provided as solid evidences and on-going rectification for preventing future mistakes. Conclusions: The report gave feasible examples for inspector to verify a large amount of data during site investigation. This program can also be extended to a scheduled data mining with software to periodical analyze the timely records in Mosaiq, for example, a various control charts for different QA purposes. As the current trend of automation in radiation therapy field, the data mining would be a necessary tool in the future, just as the automatic plan quality evaluation has been under development in Eclipse.

60 APPLIED LIFE SCIENCES↗

LLVM Infrastructure and Tools Project Summary

This project works with the open source LLVM Compiler Infrastructure (http://llvm.org) to provide tools and capabilities that address needs and challenges faced by ECP community (applications, libraries, and other components of the software stack). Our focus is on providing a more productive development environment that enables (i) improved compilation times and code generation for parallelism, (ii) additional features/capabilities within the design and implementations of LLVM components for improved platform/performance portability and (iii) improved aspects related to composition of the underlying implementation details of the programming environment, capturing resource utilization, overheads, etc. -- including runtime systems that are often not easily addressed by application and library developers.

97 MATHEMATICS AND COMPUTING↗

Chemics-Reactors: A Preliminary Python Program for Implementing Network Models of Multiphase Reactors

We discuss the design and implementation of a preliminary software package written in Python 3 that is intended to represent complex multiphase reactors as networks of ideal continuous stirred tank reactors. This software also implements statistical design of experiments, uncertainty quantification, and global sensitivity analysis. These advanced features can provide important qualitative and quantitative insights into the effect of operating conditions and model parameters on predicted reactor performance. We demonstrate the utility of the program by modeling the vapor phase catalytic upgrading of bio-oil in a bubbling fluidized bed reactor.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Implementation and Demonstration of P4 Software for Improving ICS Protocol Visibility and Control [Slides]

No prior enabling funded work applicable to this proposal. Programming Protocol-independent Packet Processors (P4) is an open source, domain-specific programming language for network switching devices. P4 complements traditional Software Defined Networking (SDN) which is primarily concerned with the management of packets (e.g. routing/dropping decisions) rather than how each packet is processed. The introduction of P4 provided new capabilities (e.g. firewall, load balancing, enhanced security) but has primarily been deployed in data centers. This effort investigates ways to expand P4 into other niches such as ICS networks.

97 MATHEMATICS AND COMPUTING↗

Analyzing the Energy and Power Consumption of Remote Memory Accesses in the OpenSHMEM Model

PGAS models like OpenSHMEM provide interfaces to explicitly initiate one-sided remote memory accesses among processes. In addition, the model also provides synchronizing barriers to ensure a consistent view of the distributed memory at different phases of an application. The incorrect use of such interfaces affects the scalability achievable while using a parallel programming model. This study aims at understanding the effects of these constructs on the energy and power consumption behavior of OpenSHMEM applications. Our experiments show that cost incurred in terms of the total energy and power consumed depends on multiple factors across the software and hardware stack. We conclude that there is a significant impact on the power consumed by the CPU and DRAM due to multiple factors including the design of the data transfer patterns within an application, the design of the communication protocols within a middleware, the architectural constraints laid by the interconnect solutions, and also the levels of memory hierarchy within a compute node. This work motivates treating energy and power consumption as important factors while designing compute solutions for current and future distributed systems.

Jana, Siddhartha↗

HEP Software Foundation Community White Paper Working Group - Data Processing Frameworks

Data processing frameworks are an essential part of HEP experiments' software stacks. Frameworks provide a means by which code developers can undertake the essential tasks of physics data processing, accessing relevant inputs and storing their outputs, in a coherent way without needing to know the details of other domains. Frameworks provide essential core services for developers and help deliver a configurable working application to the experiments' production systems. Modern HEP processing frameworks are in the process of adapting to a new computing landscape dominated by parallel processing and heterogeneity, which pose many questions regarding enhanced functionality and scaling that must be faced without compromising the maintainability of the code. In this paper we identify a program of work that can help further clarify the key concepts of frameworks for HEP and then spawn R&D activities that can focus the community's efforts in the most efficient manner to address the challenges of the upcoming experimental program.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

JBlulce Data Acquisition Software for Macromolecular Crystallography

JBlulce (Java Beam Line Universal Integrated Configuration Environment is a data acquisition software for macromolecular crystallography conforming user interface of the SSRL Blulce that has become a de-factor standard in the field. Besides this interface conformity, JBlulce is a unique system in terms of architecture, spec, capability and software implementation. It features only two software layers, the JBlulce clients and the EPICS servers, as compared to three layers present in Blulce and most of similar systems. This layers reduction provides a faster communication with hardware and an easier access to advanced hardware capabilities like on-the-fly scanning. Then JBlulce clients are designed to operate in parallel with the other beamline controls which streamlines the tasks performed by staff such as beamline preparation, maintenance, auditing and user assistance. Another distinction is the deployment of multiple plugins that can be written in any programming language thus involving more staff into the development. further on, JBlulce makes use of unified motion controls allowing for easy scanning and optimizing of any beamline component. Finally, the graphic interface is implemented in Java making full use of rich Java libraries and Jave IDE for debugging. to compare, Blulce user interface is implemented with aging Tcl/tk language providing very restricted capabilities. JBlulce makes full use of the industrial power and wide drivers selection of EPICS in controlling hardware; all hardware communication is routed via multiple EPICS servers residing on local area network. JBlulce also includes several EPICS State Notation servers aimed at making hardware communication more robust. Besides using EPICS for controlling hardware, JBlulce extensively uses EPICS databases for efficient communications between multiple instances of JBlulce clients and JBlulce plugins that can run in parallel on different computers. All of the above makes JBlulce one of the biggest and most sophisticated EPICS client projects to date. JBlulce configuration is stored in my SQL database which provides flexibility in tuning the system. The database is also accessible by the plugins. From the users perspective JBlulce provides all standard features of data acquisition software for macromolecular crystallography plus such unique capabilities as one click beamline energy change that may involve switching undulator harmonics, mirrors lanes and beam realignment, automated diffraction rtastering for finding small crystals and sweet spots on poorly diffracting crystals with automated scoring of raster cells by the number of reflections; data collection along a vector; automated on-the-fly fluorescent tastering, a faster and lower-irradiation compliment to the diffraction raster; fully automated fluorescence measurements for MAD that include signal optimization, fast on the fly energy scanning and automated adapting of scan range to chemical shifts; fly-scan minibeam realignment; automated loop and crystal centering, controls for sample automounter, automated screening, data collection auditing, remote access and a lot more.

Stepanov, Sergey↗

Accuracy of pencil-beam redefinition algorithm dose calculations in patient-like cylindrical phantoms for bolus electron conformal therapy

Purpose: The purpose of this study was to document the improved accuracy of the pencil beam redefinition algorithm (PBRA) compared to the pencil beam algorithm (PBA) for bolus electron conformal therapy using cylindrical patient phantoms based on patient computed tomography (CT) scans of retromolar trigone and nose cancer.Methods: PBRA and PBA electron dose calculations were compared with measured dose in retromolar trigone and nose phantoms both with and without bolus. For the bolus treatment plans, a radiation oncologist outlined a planning target volume (PTV) on the central axis slice of the CT scan for each phantom. A bolus was designed using the planning.decimal{sup Registered-Sign} (p.d) software (.decimal, Inc., Sanford, FL) to conform the 90% dose line to the distal surface of the PTV. Dose measurements were taken with thermoluminescent dosimeters placed into predrilled holes. The Pinnacle{sup 3} (Philips Healthcare, Andover, MD) treatment planning system was used to calculate PBA dose distributions. The PBRA dose distributions were calculated with an in-house C++ program. In order to accurately account for the phantom materials a table correlating CT number to relative electron stopping and scattering powers was compiled and used for both PBA and PBRA dose calculations. Accuracy was determined by comparing differences in measured and calculated dose, as well as distance to agreement for each measurement point.Results: The measured doses had an average precision of 0.9%. For the retromolar trigone phantom, the PBRA dose calculations had an average {+-}1{sigma} dose difference (calculated - measured) of -0.65%{+-} 1.62% without the bolus and -0.20%{+-} 1.54% with the bolus. The PBA dose calculation had an average dose difference of 0.19%{+-} 3.27% without the bolus and -0.05%{+-} 3.14% with the bolus. For the nose phantom, the PBRA dose calculations had an average dose difference of 0.50%{+-} 3.06% without bolus and -0.18%{+-} 1.22% with the bolus. The PBA dose calculations had an average dose difference of 0.65%{+-} 6.21% without bolus and 1.75%{+-} 5.94% with the bolus. From a clinical perspective an agreement of 5% or better between planned (calculated) and delivered (measured) dose is desired. Statistically, this was true for 99% ({+-}2{sigma}) of the dose points for three of the four cases for the PBRA dose calculations, the exception being the nose without bolus for which this was true for 89% ({+-}1.6{sigma}) of the dose points. For the retromolar trigone, with and without bolus, the PBA showed agreement of 5% or better for approximately 86% ({+-}1.5{sigma}) of the dose points. For the nose, with and without bolus, the PBA showed agreement of 5% or better for only approximately 58% ({+-}0.8{sigma}) of the dose points.Conclusions: The measured data, whose high precision makes them useful for evaluation of the accuracy of electron dose algorithms, will be made publicly available. Based on the spread in dose differences, the PBRA has at least twice the accuracy of the PBA. From a clinical perspective the PBRA accuracy is acceptable in the retromolar trigone and nose for electron therapy with and without bolus.

61 RADIATION PROTECTION AND DOSIMETRY↗

A mathematical programming approach for the optimal placement of flame detectors in petrochemical facilities

Flame detectors provide an important layer of protection for personnel in petrochemical plants, but effective placement can be challenging. A mixed-integer nonlinear programming formulation is proposed for optimal placement of flame detectors while considering non-uniform probabilities of detection failure. We show that this approach allows for the placement of fire detectors using a fixed sensor budget and outperforms models that do not account for imperfect detection. In this study, we develop a linear relaxation to the formulation and an efficient solution algorithm that achieves global optimality with reasonable computational effort. We integrate this problem formulation into the Python package, Chama, and demonstrate the effectiveness of this formulation on a small test case and on two real-world case studies using the fire and gas mapping software, Kenexis Effigy.

47 OTHER INSTRUMENTATION↗

Compiler-Driven FPGA Virtualization with SYNERGY

FPGAs are increasingly common in modern applications, and cloud providers now support on-demand FPGA acceleration in datacenters. Applications in datacenters run on virtual infrastructure, where consolidation, multi-tenancy, and workload migration enable economies of scale that are fundamental to the provider's business. However, a general strategy for virtualizing FPGAs has yet to emerge. While manufacturers struggle with hardware-based approaches, we propose a compiler/runtime-based solution called Synergy. We show a compiler transformation for Verilog programs that produces code able to yield control to software atsub-clock-tickgranularity according to the semantics of the original program. Synergy uses this property to efficiently support core virtualization primitives: suspend and resume, program migration, and spatial/temporal multiplexing, on hardware which is availabletoday.We use Synergy to virtualize FPGA workloads across a cluster of Intel SoCs and Xilinx FPGAs on Amazon F1. The workloads require no modification, run within 3--4x of unvirtualized performance, and incur a modest increase in FPGA fabric usage.

Computer Science↗