Search NASA⌕ Search

SEARCH · Search NASA

Results for “Conditional distribution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,189 records · Page 66

Report of the Task Group 186 on model-based dose calculation methods in brachytherapy beyond the TG-43 formalism: Current status and recommendations for clinical implementation

The charge of Task Group 186 (TG-186) is to provide guidance for early adopters of model-based dose calculation algorithms (MBDCAs) for brachytherapy (BT) dose calculations to ensure practice uniformity. Contrary to external beam radiotherapy, heterogeneity correction algorithms have only recently been made available to the BT community. Yet, BT dose calculation accuracy is highly dependent on scatter conditions and photoelectric effect cross-sections relative to water. In specific situations, differences between the current water-based BT dose calculation formalism (TG-43) and MBDCAs can lead to differences in calculated doses exceeding a factor of 10. MBDCAs raise three major issues that are not addressed by current guidance documents: (1) MBDCA calculated doses are sensitive to the dose specification medium, resulting in energy-dependent differences between dose calculated to water in a homogeneous water geometry (TG-43), dose calculated to the local medium in the heterogeneous medium, and the intermediate scenario of dose calculated to a small volume of water in the heterogeneous medium. (2) MBDCA doses are sensitive to voxel-by-voxel interaction cross sections. Neither conventional single-energy CT nor ICRU/ICRP tissue composition compilations provide useful guidance for the task of assigning interaction cross sections to each voxel. (3) Since each patient-source-applicator combination is unique, having reference data for each possible combination to benchmark MBDCAs is an impractical strategy. Hence, a new commissioning process is required. TG-186 addresses in detail the above issues through the literature review and provides explicit recommendations based on the current state of knowledge. TG-43-based dose prescription and dose calculation remain in effect, with MBDCA dose reporting performed in parallel when available. In using MBDCAs, it is recommended that the radiation transport should be performed in the heterogeneous medium and, at minimum, the dose to the local medium be reported along with the TG-43 calculated doses. Assignments of voxel-by-voxel cross sections represent a particular challenge. Electron density information is readily extracted from CT imaging, but cannot be used to distinguish between different materials having the same density. Therefore, a recommendation is made to use a number of standardized materials to maintain uniformity across institutions. Sensitivity analysis shows that this recommendation offers increased accuracy over TG-43. MBDCA commissioning will share commonalities with current TG-43-based systems, but in addition there will be algorithm-specific tasks. Two levels of commissioning are recommended: reproducing TG-43 dose parameters and testing the advanced capabilities of MBDCAs. For validation of heterogeneity and scatter conditions, MBDCAs should mimic the 3D dose distributions from reference virtual geometries. Potential changes in BT dose prescriptions and MBDCA limitations are discussed. When data required for full MBDCA implementation are insufficient, interim recommendations are made and potential areas of research are identified. Application of TG-186 guidance should retain practice uniformity in transitioning from the TG-43 to the MBDCA approach.

61 RADIATION PROTECTION AND DOSIMETRY↗

Solvation and Ion Pair Association in Aqueous Metal Sulfates: Interpretation of NDIS raw data by isobaric-isothermal molecular dynamics simulation.

We analyzed the solvation behavior of aqueous lithium, nickel, and ytterbium sulfates at ambient conditions in terms of the relevant radial distributions functions and the corresponding first-order difference of the sulfur-site neutronweighted distribution functions generated by isothermal-isobaric molecular dynamics simulation. We determined of the partial contributions to the neutronweighted distribution functions, to identify the main peaks, and the effect of the contact ion-pair configuration on the resulting H ! S coordination number. Finally, we assessed the extent of the ion-pair formation according to Poirier- DeLap formalism and highlighted the significant increase of the ion-pair association exhibited by these salts with cation charge.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Long-Term Effects of Humidity on Stainless Steel Pitting in Sea Salt Exposures

Ground 304 stainless steel (SS) samples were exposed to sea salt particles at 35 °C and two relative humidity (RH) levels for durations ranging from 1 week to 2 years. For all exposure times, pit number density and total pit volume at 40% RH were observed to be considerably greater than those at 76% RH. Statistical analysis of distributions of pit populations for both RH conditions showed that pit number density and total pit volume increased rapidly at first but slowed as exposure time increased. Cross-hatched features were observed in the 40% RH pits while ellipsoidal, faceted pits were observed at 76% RH. Optical profilometry indicated that most pits were not hemispherical. X-ray tomography provided evidence of undercutting and fissures. Piecewise curve fitting modeled the 40% RH data closely, predicting that corrosion damage would eventually plateau. However, a similar treatment of the 76% RH data suggested that corrosion damage would continuously increase, which implied that the piecewise power-law fit was limited in its ability to model atmospheric corrosion generally. Based on these observations, the operative mechanisms determining long-term corrosion behavior were hypothesized to be different depending on the RH of exposure.

36 MATERIALS SCIENCE↗

Study of Cathode Gas Diffusion Architecture for Improved Oxygen Transport in Hydroxide Exchange Membrane Fuel Cells

The high pH environment in hydroxide exchange membrane fuel cells (HEMFCs) has the potential to reach lower costs than the current proton exchange membrane fuel cells (PEMFCs), the incumbent technology. A significant difference between HEMFCs and PEMFCs is the location of water production within the cell. In PEMFCs, the water is produced on the cathode, limiting oxygen transport. In HEMFCs, the water is produced on the anode where the fuel is pure hydrogen. This allows the cathode to be optimized for oxygen transport without the presence of excess liquid water. Limiting current analysis, a technique previously used in PEMFCs, is adopted in HEMFCs to evaluate the oxygen mass transport resistances for different sections of the cathode. Through elimination of the microporous layer (MPL), gas diffusion layer (GDL), and traditional flow field and using porous nickel foam for gas distribution, the transport resistance at an operating condition of 150 kPa(g) and with the cell temperature at 80 °C was decreased from 112 s m −1 to 48 s m −1 , effectively halved. The optimal configuration for performance was found with Ni foam and a GDL, eliminating the MPL and traditional flow field, which vastly improved oxygen transport while maintaining adequate electrical contact with the cathode catalyst layer.

25 ENERGY STORAGE↗

Physics Features of TRU‐Fueled VHTRs

The current waste management strategy for spent nuclear fuel (SNF) mandated by the US Congress is the disposal of high‐level waste (HLW) in a geological repository at Yucca Mountain. Ongoing efforts on closed‐fuel cycle options and difficulties in opening and safeguarding such a repository have led to investigations of alternative waste management strategies. One potential strategy for the US fuel cycle would be to make use of fuel loadings containing high concentrations of transuranic (TRU) nuclides in the next‐generation reactors. The use of such fuels would not only increase fuel supply but could also potentially facilitate prolonged operation modes (via fertile additives) on a single fuel loading. The idea is to approach autonomous operation on a single fuel loading that would allow marketing power units as nuclear batteries for worldwide deployment. Studies have already shown that high‐temperature gas‐cooled reactors (HTGRs) and their Generation IV (GEN IV) extensions, very‐high‐temperature reactors (VHTRs), have encouraging performance characteristics. This paper is focused on possible physics features of TRU‐fueled VHTRs. One of the objectives of a 3‐year U.S. DOE NERI project was to show that TRU‐fueled VHTRs have the possibility of prolonged operation on a single fuel loading. A 3D temperature distribution was developed based on conceivable operation conditions of the 600 MWth VHTR design. Results of extensive criticality and depletion calculations with varying fuel loadings showed that VHTRs are capable for autonomous operation and HLW waste reduction when loaded with TRU fuel.

Lewis, III, Tom G.↗

Energetic-particle-modified global Alfven eigenmodes

Fully self-consistent hybrid MHD/particle simulations reveal strong energetic particle modifications to sub-cyclotron global Alfven eigenmodes (GAE) in low-aspect ratio, NSTX-like conditions. Key parameters defining the fast ion distribution function -- the normalized injection velocity v_0/v_A and central pitch -- are varied in order to study their influence on the characteristics of the excited modes. It is found that the frequency of the most unstable mode changes significantly and continuously with beam parameters, in accordance with the Doppler-shifted cyclotron resonances which drive the modes, and depending most substantially on v_0/v_A. This unexpected result is present for both counter-propagating GAEs, which are routinely excited in NSTX, and high frequency co-GAEs, which have not been previously studied. Large changes in frequency without clear corresponding changes in mode structure could indicate the existence of a new energetic particle mode, referred to here as an energetic-particle-modified GAE (EP-GAE). Additional simulations conducted for a fixed MHD equilibrium demonstrate that the GAE frequency shift cannot be explained by the equilibrium changes due to energetic particle effects.

Lestz, J B↗

A Two-Dimensional Thermal-Electrochemical Model for Prismatic Lithium Ion Cells [SWR 14-04]

The software disclosed implements the thermal and electrochemical laws of conservation in a format that can be readily implemented on to hardware, for interfacing with and controlling lithium ion cells. The model can i) accept a set value for current (or voltage), the initial states within the positive and negative electrodes, the initial cell and ambient temperatures as input, and predict the voltage (or current) under these conditions after a specified duration ii) determine whether or not a lithium ion cell can deliver the power requirement for a given set of initial conditions for the cell iii) output the distribution in temperature, current and potential across the electrodes for a given load profile.

Santhanagopalan, Shriram↗

Ion Trapping Studies and Mitigation Strategies for the EIC ERL-Based Strong Hadron Cooler

An Energy Recovery Linac based strong hadron cooler was previously considered for the Electron-Ion Collider. The required electron beam parameters for variable-energy strong hadron cooling place significant constraints on ion trapping and collective effects. This paper presents initial studies of these constraints through a combination of analytical modelling and numerical simulations of ion production, trapping behaviour, and mitigation strategies. A multi-bunch tracking framework based on ELEGANT with the ionEffects module is used to simulate machine operation over millisecond time scales, corresponding to more than 3 × 10^5 electron bunches. The simulations include modelling of ionisation processes together with transverse electron–ion dynamics, allowing the evolution and accumulation of ions to be investigated. Analytical expressions based on Gaussian beam distributions are used to estimate ion trapping conditions and benchmark the simulation results. A bi-periodic bunch spacing scheme is also investigated as a possible mitigation method by detuning the ion oscillation frequency. These studies provide an initial assessment of ion trapping in the strong hadron cooler and demonstrate possible approaches for reducing beam–ion effects.

Bi, R. [Lancaster University, Cockcroft Institute]↗

Electric Power Delivery Testing Feasibility Study (Task 6 Final Report)

This Final Report is covers the completion of the Electric Power Delivery Testing Feasibility Study. The objective of this project was to research, engineer, and demonstrate high-power laboratory testing protocols to accurately reproduce the conditions on the electric power grid representing both normal load switching and abnormalities such as short-circuit fault protection. Test circuits, equipment, and techniques were developed and proven at reduced power levels to determine the feasibility of building a large-scale high-power testing laboratory capable of testing equipment and systems at simulated high-power conditions of the U.S. power grid at distribution levels up through 38 kiloVolts (kV) and transmission levels up through 230 kV. The project delivered demonstrated testing techniques, high-voltage test equipment for load testing and synthetic short-circuit testing, and recommended designs for future implementation of a high-power testing laboratory to test equipment and systems, enabling increased reliability of the electric transmission and distribution grid.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Analog, Digital, or Enhanced Human-System Interfaces? Results of an Operator-in-the-Loop Study on Main Control Room Modernization for a Nuclear Power Plant

The second Operator Study of System Overviews (OSSO-2) was conducted with a three-person reactor operator crew in the Human Systems Simulation Laboratory (HSSL) at Idaho National Laboratory (INL) in August, 2017. The study supported control room modernization at a nuclear power plant and featured a benchmark comparison of three variants of a turbine control system (TCS): the existing analog TCS, a proposed standalone digital TCS with two displays, and the digital TCS with the addition of a third display consisting of a system overview screen. TCS prototypes were developed at INL to allow evaluation of operator performance and preferences during realistic turbine scenarios in the full-scope simulator. The study revealed that completion of turbine startup was several minutes faster with the digital TCS variants than with the conventional analog TCS. Eye tracking scan paths were more widely distributed in the overview vs. standalone TCS condition, suggesting the overview screen was cueing reactor operators to verify values across the boards. There was no significant difference in workload or situation awareness across the three interfaces. Reviewing key plant parameters showed smoother transitions during load following for the digital vs. analog TCS. Despite some performance advantages for the digital TCS variants, operators preferred the existing analog TCS. Open-ended responses suggested this finding may be more an artifact of familiarity than a reflection of dissatisfaction with the new TCS. OSSO-2 provides compelling evidence that the new digital TCS was used successfully by the operators without extensive training of rewriting of the operating procedures, suggesting high usability for the digital TCS design. Further advantages were realized through the addition of the system overview screen to provide crews with at-a-glance indicators of key turbine parameters.

99 GENERAL AND MISCELLANEOUS↗

Understanding the Evolution of Biomass Burning Particles in the Atmosphere: Analysis of BBOP Data, Laboratory Experiments, and Model Integration

Submicron particles in the atmosphere can have a profound influence on Earth’s climate [Stocker et al., 2013]. Particulate matter (PM) affects climate via both direct effects (scattering or absorption of radiation) and indirect effects (changes to the formation and properties of clouds). Biomass burning (BB) is the largest global source of submicron, carbonaceous particles [Wiedinmyer et al., 2011]. Field campaigns have shown that BB aerosol (BBA) can evolve through rapid transformations and removal processes in the atmosphere, with changing radiative and hygroscopic properties, but these processes are not well characterized. Better understanding of the evolution of biomass burning PM in the atmosphere is critical for improving the accuracy of regional to global climate models. In order to address uncertainties in the initial physical, chemical and radiative forcing of BBA and the evolution of these parameters, DOE ASR conducted an airborne field campaign, the Biomass Burning Observation Project (BBOP), during the summer and fall of 2013 to make measurements in the plumes of northwest U.S. wildfires and southeast U.S. agricultural burns. BBOP provided unique, extremely detailed trace gas and particle measurements in fresh biomass burning plumes and captured large, rapid downwind transformations within a few hours of the sources. These fast changes in properties have also been observed in laboratory-generated BB smoke in a smog chamber, but in general the controlling factors and most likely outcomes in the real atmosphere are still not clear. The goals of this project were to 1) analyze and interpret the BBOP measurements in detail, 2) conduct laboratory experiments to explore the formation of tar balls, and 3) to incorporate our findings into improved models of biomass burning emissions and aging. This research focuses on understanding the chemical, physical and optical properties and transformations of BB emissions in the near-field within hours downwind of the burn and on a more regional scale and, in turn, how BB emissions relate to climate forcing. Analysis of the BBOP data paid particular attention to relating SOA production, changes in size distribution, and mixing state to the environmental conditions (gas-phase precursors, relative humidity, radiation, oxidants, NO x , etc.). This project included subcontracts and unfunded collaborations with many of the key participants in the BBOP campaign. Professor Robert Yokelson at the University of Montana is an expert on biomass burning fuels and emissions and participated in BBOP as an unfunded collaborator. Professor Peter Buseck at Arizona State University collected particle samples during BBOP and analyzed some of them as part of this project. Unfunded collaborators include Dr. Arthur Sedlacek, III at Brookhaven National Laboratory (BNL) and Dr. Rahul Zaveri at the Pacific Northwest National Laboratory (PNNL) who were both principal investigators in the BBOP campaign, focusing on measurements and modeling, respectively. We are also working closely with Prof. Qi Zhang at UC Davis to coordinate analysis of BBOP flight data and data from the Mt. Bachelor Observatory (MBO), and with Dr. Kouji Adachi at the Meteorological Institute (Japan) to analyze laboratory-generated tar ball samples.

09 BIOMASS FUELS↗

Cesium Ion Exchange Testing Using a Three-Column System with Crystalline Silicotitanate and Hanford Tank Waste 241-AP-107

Washington River Protection Solutions (WRPS) is working to support early production of immobilized low-activity waste by feeding Hanford tank supernate from tank farms to the Hanford Waste Treatment and Immobilization Plant (WTP) Low-Activity Waste (LAW) facility. This goal incorporates the design of a Tank-Side Cesium Removal (TSCR) system, which in effect filters tank waste supernate and processes it through a cesium ion exchange medium to remove 137Cs. The 137Cs-depleted product is sent to the WTP for vitrification. Rovira et al. (2018) reported the successful Cs removal from Hanford tank 241-AP-107 waste (hereafter called AP-107) using crystalline silicotitanate (CST) ion exchange media manufactured by Honeywell UOP, LLC (product IONSIVTM R9140-B, Batch 2081000057) in a lead-lag column system. Since that testing, WRPS has changed the column design to a three-column system. WRPS requested a repeated study with AP-107 tank waste using a different batch of IONSIVTM R9140-B, Lot 2002009604, in a three-column format. A small-scale test platform was constructed to demonstrate solids filtration, Cs removal, and LAW vitrification and installed at Pacific Northwest National Laboratory. This report describes the small-scale ion exchange testing system component of the test platform and the processing of approximately 8.55 L of filtered AP-107 supernate using CST, Lot 8056262-999, that passed through a 25-mesh filter. This report also describes the Cs ion exchange batch contact testing to determine the Cs distribution coefficient and the maximum Cs loading capacity in the AP-107 tank waste matrix. Batch contact testing helps to evaluate CST performance on tank waste supernate and is often used prior to processing tank waste through ion exchange columns to assess some performance metrics (e.g., 50% Cs breakthrough). Batch contact tests were performed with the filtered AP-107 tank waste at four Cs concentrations at a phase ratio of 200 (liquid volume to exchanger mass). The distribution coefficient (K d ) at the equilibrium condition of 9.2 µg Cs/mL (AP-107 feed condition) was determined to be 806 mL AP 107/g CST. With a CST bed density of 1.01 g/mL (<25 mesh CST), this K d corresponded to a predicted 50% Cs breakthrough of 814 bed volumes (BVs). The Cs load capacity at the equilibrium feed condition was determined to be 8.3 mg Cs/g dry CST. The three-column format testing was prototypic to the intended TSCR operations, albeit on a small scale with 10-mL CST beds. Flowrate was adjusted to match the CST contact time expected for the full-scale operation, i.e., matched bed volumes per hour (BV/h) flow rate. The feed was processed downflow through the lead column, then through the middle column, and then through the polish column. Loading continued at an average of 1.88 BV/h (1.83 to 2.04 BV/h range) until the entire available AP-107 feed was processed. The Cs-decontaminated product will be provided for vitrification testing. The lead column only reached 45% Cs breakthrough after processing 855 BVs of feed. The 50% Cs breakthrough was extrapolated to occur at ~900 BVs. This extrapolated 50% Cs breakthrough value differed from the batch contact estimate (814 BVs) by 13%. The waste acceptance criteria (WAC) or contract limit for the WTP LAW vitrification facility is 3.18E-5 Ci 137 Cs per mole Na. For the AP-107 tank waste, only 0.127% of the influent 137 Cs concentration may be delivered to the WTP; this required a Cs decontamination factor of 787. The Cs effluent from the middle column reached the WAC after processing 590 BVs. Cs breakthrough from the polish column began at 590 BVs, reaching 6.3E-3 µCi/mL or 4.3E-3% Cs breakthrough after processing 844 BVs of feed.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Cesium Ion Exchange Testing Using Crystalline Silicotitanate with Hanford Tank Waste 241-AP-107

At the time of this testing, the Low-Activity Waste Pretreatment System (LAWPS) was to provide for the initial production of immobilized low-activity waste by feeding Hanford tank supernate from tank farms to the Hanford Tank Waste Treatment and Immobilization Plant (WTP) Low-Activity Waste (LAW) Facility for immobilization. Washington River Protection Solutions requested that Hanford tank waste collected from tank 241-AP-107 (hereafter called AP-107) be processed using conceived pretreatment steps (suspended solids removal by filtration, Cs removal by ion exchange) then vitrified. A small-scale test platform to demonstrate the solids filtration, Cs removal, and LAW vitrification was constructed and installed at Pacific Northwest National Laboratory. Bench-scale ion exchange testing with approximately 9 L of AP-107 supernate was conducted using crystalline silicotitanate (CST) ion exchange media. The IONSIV R9140-B CST was provided by Honeywell UOP, LLC in 2018 (Batch 2081000057). The ion exchange media was first tested with simulant and was previously described. This report describes the Cs ion exchange batch contact and column test results with the AP-107 tank waste. Batch contact testing helps to evaluate CST performance on tank waste supernate prior to processing it in the ion exchange columns. Batch contacts were performed with the waste at four Cs concentrations at a phase ratio of 200 (liquid volume to exchanger mass) with AP-107. The distribution coefficient (K d ) at the equilibrium condition of 8.57 µg Cs/mL (AP-107 feed condition) was determined to be 669 mL AP-107/g CST. With a CST bed density of 1.00 g/mL, this K d corresponded to a predicted 50% Cs breakthrough of 669 bed volumes (BVs). The Cs load capacity at the equilibrium feed condition was determined to be 7.5 mg Cs/g dry CST. The column testing was prototypic to the intended LAWPS operations in a lead-lag column format, although on a small-scale basis with 10-mL CST beds. The feed was processed downflow through the lead column and then through the lag column at ~2.2 BV/h. Loading continued until the lag column reached the WTP waste acceptance criteria (WAC) for receiving supernatant waste for vitrification (a function of the Na and 137 Cs concentrations). For AP-107, the WAC is 0.114% of the influent 137 Cs concentration; this required a Cs decontamination factor of 876. The Cs effluent from the lag column reached the WAC after processing ~410 BVs. To keep the subsequent product effluent below the WAC, a replacement lag column was prepared, the lead column was removed from service (after processing a total of 471 BVs), the lag column was put into the lead column position, and the replacement lag column was installed. Feed processing continued and after another ~290 BVs the Cs effluent from the lag column again exceeded the WAC. In both cases, the lead columns only reached 25% Cs breakthrough before removal. Although 50% Cs breakthrough was not reached, this value was estimated and averaged based on extrapolation of the loading curves (640 BVs) and agreed within 4% of the predicted 50% Cs breakthrough from batch contact test results (669 BVs). Table ES.1 summarizes the observed column performance and relevant Cs loading characteristics.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Thermal Hydraulic Experimental Test Article - Fiscal Year 2022 Final Report

The Thermal Hydraulic Experimental Test Article (THETA) is a METL vessel experiment designed for testing and validating sodium fast reactor components and phenomena. THETA has been scaled using a non-dimensional Richardson number approach to represent temperature distributions during nominal and loss of flow conditions in a sodium fast reactor (SFR), this analysis was detailed in the THETA FY19 report. The facility is being constructed with versatility in mind, allowing for the installation of various immersion heaters, heat pipes, and heat exchangers without significant facility modification. THETA was designed in collaboration with systems code experts to inform the geometry and sensor placement to acquire the highest value code validation data.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Numerical Simulation of Biogenic Fluid Catalytic Cracking (BFCC) Regenerators at Different Scales with MFIX-Exa

Catalytic Fast Pyrolysis (CFP) is a process that converts biomass into liquid intermediates suitable for transportation fuels by rapidly heating it in the presence of a catalyst, aiming to produce stable oils with reduced oxygen content. During CFP, the catalyst can become deactivated by the accumulation of coke, a carbon-rich deposit formed from the decomposition of biomass components. Unlike in petroleum refining, regenerating coked catalysts from biomass pyrolysis requires specific approaches due to the different chemical nature of the coke formed. An experimental technique, Temperature Programmed Oxidation (TPO), was used to study the de-coking process by gradually increasing temperature while monitoring the production of CO and CO2, which provides data for kinetic modeling. Utilizing data from TPO experiments, coke combustion kinetic model was developed to describe the rate of coke removal at different temperatures, allowing for simulation of regeneration processes. Then kinetic model is integrated into MFIX-Exa for the simulation of Biogenic Fluid Catalytic Cracker (BFCC) regenerator at different scales, enabling analysis of catalyst flow, temperature distribution, and regeneration efficiency under various operating conditions.

biogenic fluid catalytic cracking↗

MPACT Verification and Validation: Status and Plans

The MPACT code provides the capability to calculate the steady-state reactor core neutron distribution for operating nuclear power plant (PWR) conditions across multiple fuel cycles. This document provides an initial plan and summarizes the current status of the verification and validation (V&V) of MPACT.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Pacific Northwest GridWise™ Testbed Demonstration Projects; Part I. Olympic Peninsula Project

This report describes the implementation and results of a field demonstration wherein residential electric water heaters and thermostats, commercial building space conditioning, municipal water pump loads, and several distributed generators were coordinated to manage constrained feeder electrical distribution through the two-way communication of load status and electric price signals. The field demonstration took place in Washington and Oregon and was paid for by the U.S. Department of Energy and several northwest utilities. Price is found to be an effective control signal for managing transmission or distribution congestion. Real-time signals at 5-minute intervals are shown to shift controlled load in time. The behaviors of customers and their responses under fixed, time-of-use, and real-time price contracts are compared. Peak loads are effectively reduced on the experimental feeder. A novel application of portfolio theory is applied to the selection of an optimal mix of customer contract types.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Data-Driven Linear Parameter-Varying Modeling and Control of Flexible Loads for Grid Services

Flexible loads have great potential to improve the electric grid's flexibility and stability. To effectively control large ensembles of heterogeneous loads, reliable models thereof are required. This paper presents a data-driven modeling and control approach to manage flexible loads for providing grid services. We leverage a linear parameter-varying autoregressive moving average (LPV-ARMA) model to describe the aggregate load response, where the parameters in the model are used to capture external environmental impacts (e.g., weather). A gain-scheduling feedback controller is then developed to adapt to environmental variations. This data-driven approach can be easily applied to different types of loads in various environmental conditions. In addition to the ensemble controller, distributed load controllers are designed to deliver grid services, while maintaining the quality of service of inherent load tasks. We demonstrate the work on the IEEE 37-node distribution system for real-time power regulation services through control of thermostatically controlled loads.

61 RADIATION PROTECTION AND DOSIMETRY↗