Search NASA⌕ Search

SEARCH · Search NASA

Results for “Contamination”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,189 records · Page 66

IR excitation of contaminant water by oxygen for the space shuttle at low Earth orbit altitude

As the water outgas of a space shuttle passes through the rarefied atmosphere at orbital altitude, collisions occur between the gases with sufficient energy to excite infrared-active water molecules to various vibrational and rotational states. An infrared contaminant model (IR model) has been developed to study the shuttle-induced excitation and emission of water molecules outgassed from the space shuttle. The focus of the first application of the model is translation-to-vibration (T-V) energy transfer since estimates suggest that this process should dominate the production of vibrationally excited H2O under typical low Earth orbit conditions. Using the velocity and position distribution functions of interacting neutral gases obtained from a neutral gases interaction model, the spatial distributions of excitation and IR radiation from contaminant water are computed, and typical results are presented. Infrared spectral data (450 - 2500/cm), measured by the Cryogenic Infrared Radiance Instrumentation for Shuttle (CIRRIS-1A) sensor on STS-39 (April 28 to May 6, 1991) at an altitude near 265 km, are used to test model predictions. The dependence of the radiant emission structure and brightness on outgassing rates and altitudes is discussed. The time history of the contaminant water outgassing rate is inferred for STS-39, and it is compared with the mass-spectrometer-based results for STS-4 (June 26 to July 4, 1982). Also, estimates of H2O column density at mission elapsed time (MET) 50 hours are compared for missions STS-2, STS-3, STS-4, and STS-39.

Zhou, D. K.↗

Pulsed Plasma Thruster Contamination

Pulsed Plasma Thrusters (PPT's) are currently baselined for the Air Force Mightysat II.1 flight in 1999 and are under consideration for a number of other missions for primary propulsion, precision positioning, and attitude control functions. In this work, PPT plumes were characterized to assess their contamination characteristics. Diagnostics included planar and cylindrical Langmuir probes and a large number of collimated quartz contamination sensors. Measurements were made using a LES 8/9 flight PPT at 0.24, 0.39, 0.55, and 1.2 m from the thruster, as well as in the backflow region behind the thruster. Plasma measurements revealed a peak centerline ion density and velocity of approx. 6 x 10(exp 12) cm(exp -3) and 42,000 m/s, respectively. Optical transmittance measurements of the quartz sensors after 2 x 10(exp 5) pulses showed a rapid decrease in plume contamination with increasing angle from the plume axis, with a barely measurable transmittance decrease in the ultraviolet at 90 deg. No change in optical properties was detected for sensors in the backflow region.

Myers, Roger M.↗

Rationale and Methods for Archival Sampling and Analysis of Atmospheric Trace Chemical Contaminants On Board Mir and Recommendations for the International Space Station

Collection and analysis of spacecraft cabin air samples are necessary to assess the cabin air quality with respect to crew health. Both toxicology and engineering disciplines work together to achieve an acceptably clean cabin atmosphere. Toxicology is concerned with limiting the risk to crew health from chemical sources, setting exposure limits, and analyzing air samples to determine how well these limits are met. Engineering provides the means for minimizing the contribution of the various contaminant generating sources by providing active contamination control equipment on board spacecraft and adhering to a rigorous material selection and control program during the design and construction of the spacecraft. A review of the rationale and objectives for sampling spacecraft cabin atmospheres is provided. The presently-available sampling equipment and methods are reviewed along with the analytical chemistry methods employed to determine trace contaminant concentrations. These methods are compared and assessed with respect to actual cabin air quality monitoring needs. Recommendations are presented with respect to the basic sampling program necessary to ensure an acceptably clean spacecraft cabin atmosphere. Also, rationale and recommendations for expanding the scope of the basic monitoring program are discussed.

Perry, J. L.↗

Performance Testing of a Russian Mir Space Station Trace Contaminant Control Assembly

A filter assembly which is incorporated into the Russian Trace Contaminant Control Assembly was tested for removal of airborne trace chemical contaminants in a closed loop 9 m(exp 3) system. Given contaminant loading rates and maximum allowable atmospheric concentrations, the Russian system was able to maintain system air concentrations below maximum allowable limits. This was achieved for both a new filter system and for a system where a part of it was pre-loaded to emulate 3 years of system age.

Curtis, R. E.↗

1997 Spacecraft Contamination and Coatings Workshop

This volume contains the presentation charts of talks given at the "1997 Spacecraft Contamination and Coatings Workshop," held July 9-10, 1997, in Annapolis, Maryland. The workshop was attended by representatives from NASA, Jet Propulsion Laboratory, Department of Defense, industry, and universities concerned with the the spacecraft contamination engineering and thermal control coatings. The workshop provided a forum for exchanging new developments in spacecraft contamination and coatings.

Chen, Philip T.↗

Use of Variable Angle Spectroscopic Ellipsometry in Order to Determine Contaminant Optical Properties

In order to measure contaminant levels found in the manufacture of the Redesigned Solid Rocket Motor (RSRM), optical properties of the contaminants are needed to develop standards for calibration purposes. Specific to our efforts is the determination of the complex index of refraction for a hydrocarbon mixture and a commercial methyl siloxane. Using ellipsometric measurements with multiple angles of incident and a range of wavelengths in the near infrared a determination of the index of refraction and the extinction coefficient were made for the contaminants. This paper will present the optical techniques and modeling approach used to determine these optical constants of the hydrocarbon mixture and the methyl siloxane studied.

Hughes, C.↗

Earth Observing System/Meteorological Satellite (EOS/METSAT). Advanced Microwave Sounding Unit-A (AMSU-A) Contamination Control Plan

This Contamination Control Plan is submitted in response the Contract Document requirements List (CDRL) 007 under contract NAS5-32314 for the Earth Observing System (EOS) Advanced Microwave Sounding Unit A (AMSU-A). In response to the CDRL instructions, this document defines the level of cleanliness and methods/procedures to be followed to achieve adequate cleanliness/contamination control, and defines the required approach to maintain cleanliness/contamination control through shipping, observatory integration, test, and flight. This plan is also applicable to the Meteorological Satellite (METSAT) except where requirements are identified as EOS-specific. This plan is based on two key factors: a. The EOS/METSAT AMSU-A Instruments are not highly contamination sensitive. b. Potential contamination of other EOS Instruments is a key concern as addressed in Section 9/0 of the Performance Assurance Requirements for EOS/METSAT Integrated Programs AMSU-A Instrument (MR) (NASA Specification S-480-79).

Fay, M.↗

Contamination Control Changes to the Reusable Solid Rocket Motor Program: A Ten Year Review

During the post Challenger period, the National Aeronautics and Space Administration and Thiokol implemented changes to the Reusable Solid Rocket Motor (RSRM) contract to include provisions for contamination control to enhance the production environment. During the ten years since those agreements for contamination controls were made, many changes have taken place in the production facilities at Thiokol. These changes have led to the production of much higher quality shuttle solid rocket motors and improved cleanliness and safety of operations in the production facilities. The experience in contamination control over this past decade highlights the value these changes have brought to the RSRM program, and how the system can be improved to meet the challenges the program will face in the next ten years.

Bushman, David M.↗

Calibration Results for the AXAF Flux Contamination Monitor

The Flux Contamination Monitor (FCM) on the Advanced X-ray Astrophysics Facility (AXAF) serves the purposes of transfering the absolute flux calibration from the ground calibration at the X-Ray Calibration Facility (XRCF) at Marshall Space Flight Center to operation on orbit and of detecting any changes in molecular contamination of the High Resolution Mirror Assembly (HRMA) between ground calibration and the post-launch activation phase. we describe the design, construction, and characterization of the FCM radioactive sources, and their placement on the Forward Contamination Cover (FCC). We present results from FCM measurements with the AXAF focal plane instruments, particularly the AXAF CCD Imaging Spectrometer (ACIS), during the ground calibration phase at XRCF in 1997. Finally, we describe the plans for FCM on-orbit measurements during observatory activation and the subsequent analysis.

Elsner, Ronald F.↗

Calibration Results for the AXAF Flux Contamination Monitor

The AXAF Flux Contamination Monitor (FCM) serves the purposes of transferring the absolute flux calibration from the ground calibration at the X-Ray Calibration Facility (XRCF) to operation on orbit and of detecting any changes in molecular contamination of the High-Resolution Mirror Assembly (HRMA) between ground calibration and the post-launch activation. We describe the design, construction, and characterization of the FCM radioactive sources, and their placement on the Forward Contamination Cover (FCC). We present results from FCM measurements with the AXAF focal-plane instruments, particularly the AXAF CCD Imaging Spectrometer (ACIS), during the ground calibration phase at the XRCF in 1997. Finally, we describe the plans for FCM on-orbit measurements during observatory activation and for the subsequent analysis.

Elsner, R. F.↗

Measurements with the Chandra Flight Contamination Monitor

NASA's Chandra X-ray Observatory includes a Flight Contamination Monitor (FCM), a system of 16 radioactive calibration sources mounted to the inside of the Observatory's forward contamination cover. The purpose of the FCM is to verify the ground-to-orbit transfer of the Chandra flux scale, through comparison of data acquired during the ground calibration with those obtained in orbit, immediately prior to opening the Observatory's sun-shade door. Here we report results of these measurements, which place limits on the change in mirror-detector system response and, hence, on any accumulation of molecular contamination on the mirrors' iridium-coated surfaces.

Elsner, R. E.↗

A Contaminant Ice Visualization Experiment in a Glass Pulse Tube

Results are presented from pulse tube experiments designed to investigate the effect of 400 parts per million water vapor contamination of the helium working gas. The experiments were conducted in a glass pulse tube to enable visualization of ice formation on internal surfaces. Photographs of this ice formation were taken along with simultaneous coldtip temperature and compressor power measurements. Four types of regenerator elements were tested in various combinations: 200- and 400-mesh stainless steel screens, 1.6 mm diameter glass beads, and 1.6 mm thick perforated plastic plates. Internal spacers were also used to provide clear fields of view into the regenerator stack. Substantial water-ice formation was observed at the cold end of the regenerator and on the inside wall of pulse tube; it appeared to be highly porous, like snow, and was seen to accumulate only in a very localized region at the coldest end, despite changing the cold tip temperature across a range of 150 to 235 K. Ice formation degraded pulse tube thermal performance only in cases where screen regenerators were used at the regenerator cold end. It was concluded that flow blockage was the mechanism by which contaminants affected performance; coarse regenerator elements were largely immune over the tested time scale of a few days. Substantially reduced ice formation and minimal performance loss were also observed in repeated tests where the contaminated gas was reused after warming up and melting of the accumulated internal ice. Significant adsorption of the liquid water onto the regenerator was inferred, a process that depleted the gas phase concentration of water.

Hall, J. L.↗

Hall Effect Thruster Plume Contamination and Erosion Study

The objective of the Hall effect thruster plume contamination and erosion study was to evaluate the impact of a xenon ion plume on various samples placed in the vicinity of a Hall effect thruster for a continuous 100 hour exposure. NASA Glenn Research Center was responsible for the pre- and post-test evaluation of three sample types placed around the thruster: solar cell cover glass, RTV silicone, and Kapton(R). Mass and profilometer), were used to identify the degree of deposition and/or erosion on the solar cell cover glass, RTV silicone, and Kapton@ samples. Transmittance, reflectance, solar absorptance, and room temperature emittance were used to identify the degree of performance degradation of the solar cell cover glass samples alone. Auger spectroscopy was used to identify the chemical constituents found on the surface of the exposed solar cell cover glass samples. Chemical analysis indicated some boron nitride contamination on the samples, from boron nitride insulators used in the body of the thruster. However, erosion outweighted contamination. All samples exhibited some degree of erosion. with the most erosion occurring near the centerline of the plume and the least occurring at the +/- 90 deg positions. For the solar cell cover glass samples, erosion progressed through the antireflective coating and into the microsheet glass itself. Erosion occurred in the solar cell cover glass, RTV silicone and Kapton(R) at different rates. All optical properties changed with the degree of erosion, with solar absorptance and room temperature emittance increasing with erosion. The transmittance of some samples decreased while the reflectance of some samples increased and others decreased. All results are consistent with an energetic plume of xenon ions serving as a source for erosion.

Jaworske, Donald A.↗

The Hubble Space Telescope Servicing Mission 3A Contamination Control Program

After nearly 10 years on-orbit, the Hubble Space Telescope (HST) external thermal control materials and paint have degraded due to exposure to the low Earth orbit environment. This presented a potentially large on-orbit contamination source (particles and/or debris). Contamination mitigation techniques were developed to augment existing on-orbit servicing contamination controls. They encompassed mission management, crew training, and crew aids and tools. These techniques were successfully employed during the HST Servicing Mission 3A, December 1999.

Hansen, Patricia A.↗

Mechanical Abrasion as a Low Cost Technique for Contamination-Free Sample Acquisition from a Category IVA Clean Platform

The proposed Mars Sample Transfer Chain Architecture provides Planetary Protection Officers with clean samples that are required for the eventual release from confinement of the returned Martian samples. At the same time, absolute cleanliness and sterility requirement is not placed of any part of the Lander (including the deep drill), Mars Assent Vehicle (MAV), any part of the Orbiting Sample container (OS), Rover mobility platform, any part of the Minicorer, Robotic arm (including instrument sensors), and most of the caching equipment on the Rover. The removal of the strict requirements in excess of the Category IVa cleanliness (Pathfinder clean) is expected to lead to significant cost savings. The proposed architecture assumes that crosscontamination renders all surfaces in the vicinity of the rover(s) and the lander(s) contaminated. Thus, no accessible surface of Martian rocks and soil is Earth contamination free. As a result of the latter, only subsurface samples (either rock or soil) can be and will be collected for eventual return to Earth. Uncontaminated samples can be collected from a Category IVa clean platform. Both subsurface soil and rock samples can be maintained clean if they are collected by devices that are self-contained and clean and sterile inside only. The top layer of the sample is removed in a manner that does not contaminate the collection tools. Biobarrier (e.g., aluminum foil) covering the moving parts of these devices may be used as the only self removing bio-blanket that is required. The samples never leave the collection tools. The lids are placed on these tools inside the collection device. These single use tools with the lid and the sample inside are brought to Earth in the OS. The lids have to be designed impenetrable to the Earth organisms. The latter is a well established art.

Dolgin, B.↗

The Swift Project Contamination Control Program: A Case study of Balancing Cost, Schedule and Risk

The Swift Observatory will be launched in early 2004 to examine the dynamic process of gamma ray burst (GRB) events. The multi-wavelength Observatory will study the GRB afterglow characteristics, which will help to answer fundamental questions about both the structure and the evolution of the universe. The Swift Observatory Contamination Control Program has been developed to aid in ensuring the success of the on-orbit performance of two of the primary instruments: the Ultraviolet and Optical Telescope (UVOT) and the X-Ray Telescope (XRT). During the design phase of the Observatory, the contamination control program evolved and trade studies were performed to assess the risk of contaminating the sensitive UVOT and XRT optics during both pre-launch testing and on-orbit operations, within the constraints of the overall program cost and schedule.

Hansen, Patricia A.↗

Forward Contamination of the Moon and Mars: Implications for Future Life Detection Missions

NASA and ESA have outlined new visions for solar system exploration that will include a series of lunar robotic missions to prepare for, and support a human return to the Moon, and future human exploration of Mars and other destinations. One of the guiding principles for exploration is to pursue compelling scientific questions about the origin and evolution of life. The search for life on objects such as Mars will require that all spacecraft and instrumentation be sufficiently cleaned and sterilized prior to launch to ensure that the scientific integrity of extraterrestrial samples is not jeopardized by terrestrial organic contamination. Under COSPAR's current planetary protection policy for the Moon, no sterilization procedures are required for outbound lunar spacecraft. Nonetheless, future in situ investigations of a variety of locations on the Moon by highly sensitive instruments designed to search for biologically derived organic compounds would help assess the contamination of the Moon by lunar spacecraft. These studies could also provide valuable "ground truth" data for Mars sample return missions and help define planetary protection requirements for future Mars bound spacecraft carrying life detection experiments. In addition, studies of the impact of terrestrial contamination of the lunar surface by the Apollo astronauts could provide valuable data to help refine future Mars surface exploration plans for a human mission to Mars.

Glavin, Daniel P.↗

Extraction of Profile Information from Cloud Contaminated Radiances

Clouds act to reduce the signal level and may produce noise dependence on the complexity of the cloud properties and the manner in which they are treated in the profile retrieval process. There are essentially three ways to extract profile information from cloud contaminated radiances: (1) cloud-clearing using spatially adjacent cloud contaminated radiance measurements, (2) retrieval based upon the assumption of opaque cloud conditions, and (3) retrieval or radiance assimilation using a physically correct cloud radiative transfer model which accounts for the absorption and scattering of the radiance observed. Cloud clearing extracts the radiance arising from the clear air portion of partly clouded fields of view permitting soundings to the surface or the assimilation of radiances as in the clear field of view case. However, the accuracy of the clear air radiance signal depends upon the cloud height and optical property uniformity across the two fields of view used in the cloud clearing process. The assumption of opaque clouds within the field of view permits relatively accurate profiles to be retrieved down to near cloud top levels, the accuracy near the cloud top level being dependent upon the actual microphysical properties of the cloud. The use of a physically correct cloud radiative transfer model enables accurate retrievals down to cloud top levels and below semi-transparent cloud layers (e.g., cirrus). It should also be possible to assimilate cloudy radiances directly into the model given a physically correct cloud radiative transfer model using geometric and microphysical cloud parameters retrieved from the radiance spectra as initial cloud variables in the radiance assimilation process. This presentation reviews the above three ways to extract profile information from cloud contaminated radiances. NPOESS Airborne Sounder Testbed-Interferometer radiance spectra and Aqua satellite AIRS radiance spectra are used to illustrate how cloudy radiances can be used in the profile retrieval process.

Smith, W. L.↗