Search NASA⌕ Search

SEARCH · Search NASA

Results for “DEVICES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,189 records · Page 66

HVPE-Grown GaAs//Si Tandem Device Performance

The performance of III-V//Si tandem devices has successfully exceeded the theoretical efficiency limit of single junction Si devices (29.4%) yet the costs associated with these high-efficiency tandem devices are still too high to compete with today's conventional Si solar cells. Recent cost modeling efforts suggest that hydride vapor phase epitaxy (HVPE) could be adopted as an alternative growth technique to metal-organic chemical vapor deposition (MOCVD) because the costs of HVPE are substantially lower and the performance of devices fabricated from HVPE materials are continuously improving. This study reports on our first results of a HVPE-grown GaAs top cell mechanically stacked on a Si bottom cell.

14 SOLAR ENERGY↗

(110)-Oriented GaAs Devices and Spalling as a Platform for Low-Cost III-V Photovoltaics

We demonstrate the growth of (110) GaAs solar cells by hydride vapor phase epitaxy (HVPE) as an advance towards a (110)-oriented device platform with substrate reuse via spalling. Controlled spalling offers a fracture-based path to substrate amortization, allowing device removal and substrate reuse, but the faceted surface generated in spalling of (100)-GaAs presents hurdles to direct regrowth of subsequent devices. Spalling of (110)-oriented substrates takes advantage of the natural (110) cleavage plane in zinc-blende III-V materials, eliminating this faceting. The vast majority of III-V epitaxy development is on (100)-oriented substrates, but epitaxy is not limited to this orientation. Here, we demonstrate (110)-based GaAs solar cells grown by HVPE with equivalent performance to devices grown on the more standard (100) orientation. We also demonstrate spalling of (110) oriented substrates, revealing surfaces with flat terraces separated by steps. These results provide preliminary evidence of a potentially low-cost path for terrestrial III-V photovoltaics via the (110) substrate orientation.

(110) orientation↗

Arsenic Doping of Polycrystalline CdSeTe Devices for Microsecond Life-times with High Carrier Concentrations

We report seminal advances in fabrication and understanding of group V (As) doped thin-film polycrystalline CdTe-based solar cells. The devices are fabricated using a novel approach, by sublimating layers of CdSeTe and CdSeTe:As. This new method allowed us to achieve minority carrier lifetime of over 1 μs, carrier concentration of more than 5×l0 15 cc -1 and external radiative efficiency of over 2 % in a device configuration. We find an increase in open-circuit voltage when comparing As-doped, Cu-doped and undoped devices. The choice of CdSeTe instead of a CdTe-only absorber has been explained using first-principle density functional theory model. A SCAPS device model is used to analyze the potential causes for lower open-circuit voltage.

Munshi, Amit H.↗

Na Diffusion and Device Performance of AgBr Treated CuGaSe 2 Thin Films

Previous work demonstrated that uniform CuGaSe2 (CGS) thin films with large grains could be grown using a short AgBr vapor treatment during growth. Here, devices made with this treated CGS showed better performance compared to devices made with standard material. Here, it is shown that AgBr treated CGS device performance worsens over time and is attributed to the suppression of Na diffusion. A NaF post-deposition treatment is shown to effectively introduce Na into the AgBr treated CGS film and prevent device degradation.

14 SOLAR ENERGY↗

Characterizing the Stability of NISQ Devices

In this study, we focus on the question of stability of NISQ devices. The parameters that define the device stability profile are motivated by the work of DiVincenzo in [9] where the requirements for physical implementation of quantum computing are discussed. We develop the metrics and theoretical framework to quantify the DiVincenzo requirements and study the stability of those key metrics. The basis of our assessment is histogram similarity (in time and space). For identical experiments, devices which produce reproducible histograms in time, and similar histograms in space, are considered more reliable. To investigate such reliability concerns robustly, we propose a moment-based distance (MBD) metric. We illustrate our methodology using data collected from IBM's Yorktown device. Two types of assessments are discussed: spatial stability and temporal stability.

Dasgupta, Samudra↗

Adaptive stabilization of quantum circuits executed on unstable devices

Conventional computers have evolved to device components that demonstrate failure rates of 10 −17 or less, while current quantum computing devices typically exhibit error rates of 10 −2 or greater. This raises concerns about the reliability and reproducibility of the results obtained from quantum computers. The problem is highlighted by experimental observation that today’s NISQ devices are inherently unstable. Remote quantum cloud servers typically do not provide users with an ability to calibrate the device themselves. Using inaccurate characterization data for error mitigation can have devastating impact on reproducibility. In this study, we investigate if one can infer the critical channel parameters dynamically from the noisy binary output of the executed quantum circuit and use it to improve program stability. An open question however is how well does this methodology scale. We discuss the efficacy and efficiency of our adaptive algorithm using canonical quantum circuits such as the uniform superposition circuit. Our metric of performance is the Hellinger distance between the post-stabilization observations and the reference (ideal) distribution.

Dasgupta, Samudra↗

Reliable Devices Yield Stable Quantum Computations

Stable quantum computation requires noisy results to remain bounded even in the presence of noise fluctuations. Yet non-stationary noise processes lead to drift in the varying characteristics of a quantum device that can greatly influence the circuit outcomes. Here we address how temporal and spatial variations in noise relate device reliability to quantum computing stability. First, our approach quantifies the differences in statistical distributions of characterization metrics collected at different times and locations using Hellinger distance. We then validate an analytical bound that relates this distance directly to the stability of a computed expectation value. Our demonstration uses numerical simulations with models informed by the washington superconducting transmon device. We find that the stability metric is consistently bounded from above by the corresponding Hellinger distance, which can be cast as a specified tolerance level. These results underscore the significance of reliable quantum computing devices and the impact for stable quantum computation.

Dasgupta, Samudra↗

Electroluminescence and Transmission Electron Microscopy Characterization of Reverse-Biased AlGaN/GaN Devices

Reverse-bias stress testing has been applied to a large set of more than 50 AlGaN/GaN high electron mobility transistors, which were fabricated using the same process but with different values of the AlN mole fraction and the AlGaN barrier-layer thickness, as well as different substrates (SiC and sapphire). Two sets of devices having different defect types and densities, related to the different growth conditions and the choice of nucleation layer, were also compared. When subjected to gate drain (or gate-to-drain and source short-circuited) reverse-bias testing, all devices presented the same time-dependent failure mode, consisting of a significant increase in the gate leakage current. This failure mechanism occurred abruptly during step-stress experiments when a certain negative gate voltage, or critical voltage, was exceeded or, during constant voltage tests, at a certain time, defined as time to breakdown. Electroluminescence (EL) microscopy was systematically used to identify localized damaged areas that induced an increase of gate reverse current. This current increase was correlated with the increase of EL intensity, and significant EL emission during tests occurred only when the critical voltage was exceeded. Focused-ion-beam milling produced cross-sectional samples suitable for electron microscopy observation at the sites of failure points previously identified by EL microscopy. In highdefectivity devices, V-defects were identified that were associated with initially high gate leakage current and corresponding to EL spots already present in untreated devices. Conversely, identification of defects induced by reverse-bias testing proved to be extremely difficult, and only nanometer-size cracks or defect chains, extending vertically from the gate edges through the AlGaN/GaN heterojunction, were found. No signs of metal/semiconductor interdiffusion or extended defective areas were visible.

Cullen, David A↗

Methodology for Wide Band-Gap Device Dynamic Characterization

Here, the double pulse test (DPT) is a widely accepted method to evaluate the dynamic behavior of power devices. Considering the high switching-speed capability of wide band-gap devices, the test results are very sensitive to the alignment of voltage and current (V-I) measurements. Also, because of the shoot-through current induced by Cdv/dt (i.e., cross-talk), the switching losses of the nonoperating switch device in a phase-leg must be considered in addition to the operating device. This paper summarizes the key issues of the DPT, including components and layout design, measurement considerations, grounding effects, and data processing. Additionally, a practical method is proposed for phase-leg switching loss evaluation by calculating the difference between the input energy supplied by a dc capacitor and the output energy stored in a load inductor. Based on a phase-leg power module built with 1200-V/50-A SiC MOSFETs, the test results show that this method can accurately evaluate the switching loss of both the upper and lower switches by detecting only one switching current and voltage, and it is immune to V-I timing misalignment errors.

30 DIRECT ENERGY CONVERSION↗

Classification of Unintended Radiated Emissions in a Multi-Device Environment

Here, unintended radiated emissions (URE) from electronic devices are conducted on to the power infrastructure and can be collected and analyzed for non-intrusive load monitoring (NILM) applications. Dimensionally aligned signal projections (DASP) were previously introduced as specialized signal transforms to enable device classification using machine learning on statistical features derived from the DASP transforms. In this work, we explore multi-device classification which requires more sophisticated methods owing to the complexity of the feature space such as large dynamic range, non-contiguous features, over-lapping features, and nonlinear interactions of features. In particular, we introduce an additional DASP algorithm for increased resolution and sensitivity to intermodulation products and examine the utility of convolutional neural networks (CNNs) to extract and learn features directly from DASP images for classification of single and multiple device URE captures.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Fabrication of fluidic devices with 30 nm nanochannels by direct imprinting

In this work, we propose an innovative approach to the fabrication of a complete micro/nano fluidic system, based on direct nanoimprint lithography. The fabricated device consists of nanochannels connected to U-shaped microchannels by triangular tapered inlets, and has four large reservoirs for liquid input. A master silicon stamp with the multilevel structures is fabricated first, and then a negative replica is made, to be used as a stamp for ultraviolet nanoimprint lithography (UV-NIL). Afterwards, just one single UV-NIL step is necessary for patterning all the the micro and nanostructures. Furthermore, the devices are made of all-transparent materials, and the method allows flexibility for the type of substrates used. The active material (an inorganic-organic hybrid polymer) used for the fabrication of the device has been carefully chosen, so it has adequate surface properties (inert and hydrophilic) for its direct use for biological applications. Devices having 30 nm wide, 30 nm deep nanochannels have been fabricated, and the successful performance of the fluidic system and the continuity of the nanochannels have been proven by flow tests.

42 ENGINEERING↗

Dry etching techniques for active devices based on hexagonal boron nitride epilayers

Hexagonal boron nitride (hBN) has emerged as a fundamentally and technologically important material system owing to its unique physical properties including layered structure, wide energy bandgap, large optical absorption, and neutron capture cross section. As for any materials under development, it is necessary to establish device processing techniques to realize active devices based on hBN. The authors report on the advancements in dry etching techniques for active devices based on hBN epilayers via inductively coupled plasma (ICP). The effect of ICP radio frequency (RF) power on the etch rate and vertical side wall profile was studied. The etching depth and angle with respect to the surface were measured using atomic force microscopy showing that an etching rate ∼1.25 μm/min and etching angles >80° were obtained. Profilometer data and scanning electron microscope images confirmed these results. This work demonstrates that SF{sub 6} is very suitable for etching hBN epilayers in RF plasma environments and can serve as a guide for future hBN device processing.

36 MATERIALS SCIENCE↗

Development and optimization of a beam shaper device for a mobile dedicated IOERT accelerator

Purpose: The aim of this study was to design and build a prototype beam shaper to be used on a dedicated mobile accelerator that protects organs at risk within the radiation field and conforms the beam to the target geometry during intraoperative electron radiotherapy (IOERT). A dosimetric characterization of the beam shaper device was performed based on Monte Carlo (MC) simulations, as well as experimental data, at different energies, field sizes, and source to skin distances. Methods: A mobile light intraoperative accelerator (LIAC{sup Registered-Sign }, Sordina, Italy) was used. The design of the beam shaper prototype was based on MC simulations (BEAMnrc/OMEGA and DOSXYZnrc code) for a selection of materials and thicknesses, as well as for dosimetric characterization. Percentage depth dose (PDD) and profile measurements were performed using a p-type silicon diode and a commercial water phantom, while output factors were measured using a PinPoint ion chamber in a PMMA phantom. Planar doses in planes of interest were carried out using radiochromic films (Gafchromic{sup TM} EBT and EBT2) in PMMA and in a Solid Water{sup Registered-Sign} phantom. Several experimental set-ups were investigated with the beam shaper device fixed on the top of the phantom, varying both the short side of the rectangular field and the air gap between the device and the phantom surface, simulating the clinical situation. The output factors (OFs) were determined using different geometrical set-ups and energies. Results: The beam shaper prototype consists of four blades sliding alongside each other and mounted on a special support at the end of the 10 cm diameter PMMA circular applicator. Each blade is made of an upper layer of 2.6 cm of Teflon{sup Registered-Sign} and a lower layer of 8 mm of stainless steel. All rectangles inscribed in a 5 cm diameter can be achieved in addition to any 'squircle-shaped' field. When one side of the rectangular field is held constant and the second side is reduced, both R{sub 50} and R{sub max} move towards the phantom surface. Comparing the PDDs obtained with the 5 cm circular applicator and with a 4.4 Multiplication-Sign 4.4 cm{sup 2} square field (that is the equivalent square of the 5 cm circular field) obtained with the beam shaper, a different behavior was observed in the region extending from the surface to a depth of 50% of the maximum dose. Isodoses measured for rectangular fields used for clinical cases (i.e., 4 Multiplication-Sign 9 cm{sup 2} 8 MeV) are shown, with different air gaps. For each energy investigated, the normalized OFs slowly increase, when the length of the side decreases down to about 4 cm, and then rapidly decreases for smaller field widths. MC simulation showed an excellent agreement with experimental data (<2%). Conclusions: The beam shaper device is able to provide square/rectangular/squircle fields with adequate dose homogeneity for mobile dedicated accelerators, thus allowing conformal treatment with IOERT. Monte Carlo simulation can be a very useful tool to simulate any clinical set up and can be used to create a data set to calculate MUs, thereby increasing the accuracy of the delivered dose during IOERT procedures.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dosimetric and geometric evaluation of a novel stereotactic radiotherapy device for breast cancer: The GammaPod Trade-Mark-Sign

Purpose: A dedicated stereotactic gamma irradiation device, the GammaPod Trade-Mark-Sign from Xcision Medical Systems, was developed specifically to treat small breast cancers. This study presents the first evaluation of dosimetric and geometric characteristics from the initial prototype installed at University of Maryland Radiation Oncology Department. Methods: The GammaPod Trade-Mark-Sign stereotactic radiotherapy device is an assembly of a hemi-spherical source carrier containing 36 {sup 60}Co sources, a tungsten collimator, a dynamically controlled patient support table, and the breast immobilization system which also functions as a stereotactic frame. The source carrier contains the sources in six columns spaced longitudinally at 60 Degree-Sign intervals and it rotates together with the variable-size collimator to form 36 noncoplanar, concentric arcs focused at the isocenter. The patient support table enables motion in three dimensions to position the patient tumor at the focal point of the irradiation. The table moves continuously in three cardinal dimensions during treatment to provide dynamic shaping of the dose distribution. The breast is immobilized using a breast cup applying a small negative pressure, where the immobilization cup is embedded with fiducials also functioning as the stereotactic frame for the breast. Geometric and dosimetric evaluations of the system as well as a protocol for absorbed dose calibration are provided. Dosimetric verifications of dynamically delivered patient plans are performed for seven patients using radiochromic films in hypothetical preop, postop, and target-in-target treatment scenarios. Results: Loaded with 36 {sup 60}Co sources with cumulative activity of 4320 Ci, the prototype GammaPod Trade-Mark-Sign unit delivers 5.31 Gy/min at the isocenter using the largest 2.5 cm diameter collimator. Due to the noncoplanar beam arrangement and dynamic dose shaping features, the GammaPod Trade-Mark-Sign device is found to deliver uniform doses to targets with good conformity. The spatial accuracy of the device to locate the radiation isocenter is determined to be less than 1 mm. Single shot profiles with 2.5 cm collimator are measured with radiochromic film and found to be in good agreement with respect to the Monte Carlo based calculations (congruence of FWHM less than 1 mm). Dosimetric verifications corresponding to all hypothetical treatment plans corresponding to three target scenarios for each of the seven patients demonstrated good agreement with gamma index pass rates of better than 97% (99.0%{+-} 0.7%). Conclusions: Dosimetric evaluation of the first GammaPod Trade-Mark-Sign stereotactic breast radiotherapy unit was performed and the dosimetric and spatial accuracy of this novel technology is found to be feasible with respect to clinical radiotherapy standards. The observed level of agreement between the treatment planning system calculations and dosimetric measurements has confirmed that the system can deliver highly complex treatment plans with remarkable geometric and dosimetric accuracy.

60 APPLIED LIFE SCIENCES↗

SU-E-T-447: Growth of Metal Whiskers Under External Beam Irradiation: Experimental Evidence and Implications in Medical Electronic Devices for Radiation Therapy Treatments

Purpose: Thin metallic protrusions, termed “whiskers,” have been identified as a cause of failure in devices ranging from satellites to pacemakers. For decades, lead was used in tin-based soldering alloys to suppress whisker formation. With the adoption of the Restriction of Hazardous Substances act and the expiration of its exemption on medical devices, including implanted medical devices (IMDs), electronic circuits are required to be lead-free as of July 2014. The effect of radiation on such soldering components remains unknown. Methods: We have irradiated a thin (150 nm) tin metal layer, deposited on a 3 mm thick glass substrate, with a 6 MeV medical linac (Varian TrueBeam) electron beam in five 2-hour long sessions. After receiving ∼10 kGy, whisker growth on the sample was assessed with scanning electron microscopy and compared to a reference sample not exposed to radiation. Results: After 10 hours of irradiation, the sample was found to develop intense whisker infestation, while the reference sample remained in its pristine as-deposited condition. Repeating the same irradiation schedule generated more and longer whiskers. The observed phenomenon can be explained through charge accumulation in the glass substrate, generating an electric field that promotes whisker growth. The observed substrate glass darkening under irradiation points towards development of color centers related to charge trapping. Experiments on the same type of samples with direct application of the external field in a capacitor-like setting also resulted in intense whisker growth. Conclusion: Extreme care should be taken in dealing with all electronic devices, especially IMDs, produced with lead-free solder and components, subject to radiation exposure. While in our experiments strong electric fields were intentionally generated to accelerate whisker growth over hours, in everyday use the circuit soldering may cause problems in a matter of days or months. Designated reliability testing under radiation must be conducted. This work is partially supported by NRC grant No. NRC-HQ-12-G-38-0042.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-F-I-15: Evaluation of a New MR-Compatible Respiratory Motion Device at 3T

Purpose: Recent advances in MRI-guided radiotherapy has inspired the development of MRI-compatible motion devices that simulate patient periodic motion in the scanner, particularly respiratory motion. Most commercial devices rely on non MR-safe ferromagnetic stepper motors which are not practical for regular QA testing. This work evaluates the motion performance of a new fully MRI compatible respiratory motion device at 3T. Methods: The QUASAR™ MRI-compatible respiratory motion phantom has been recently developed by Modus QA Inc., London, ON, Canada. The prototype is constructed from diamagnetic materials with linear motion generated using MRI-compatible piezoelectric motors that can be safely inserted in the scanner bore. The tumor was represented by a fillable sphere and is attached to the linear motion generator. The spherical tumor-representative and its surroundings were filled with different concentrations of MnCl2 to produce realistic relaxation times. The motion was generated along the longitudinal (H/F) axis of the bore using sinusoidal reference waveform (amplitude = 15 mm, frequency 0.25 Hz). Imaging was then performed on 3T Philips Achieva using a 32-channel cardiac coil. Fast 2D spoiled gradient-echo was used with a spatial resolution of 1.8 × 1.8 mm{sup 2} and slice thickness of 4 mm. The motion waveform was then measured on the resultant image series by tracking the centroid of the sphere through the time series. This image-derived measured motion was compared to the software-generated reference waveform. Results: No visible distortions from the device were observed on the images. Excellent agreement between the measured and the reference waveforms were obtained. Negligible motion was observed in the lateral (R/L) direction. Conclusion: Our investigation demonstrates that this piezo-electric motor design is effective at simulating periodic motion and is a potential candidate for MRI-radiotherapy respiratory motion simulation. Future work should focus on evaluating non-sinusoidal waveforms, fast 3D pulse sequences, and perform dosimetric QA.

60 APPLIED LIFE SCIENCES↗

SU-F-T-18: The Importance of Immobilization Devices in Brachytherapy Treatments of Vaginal Cuff

Purpose: High dose rate brachytherapy is a highly localized radiation therapy that has a very high dose gradient. Thus one of the most important parts of the treatment is the immobilization. The smallest movement of the patient or applicator can result in dose variation to the surrounding tissues as well as to the tumor to be treated. We will revise the ML Cylinder treatments and their localization challenges. Methods: A retrospective study of 25 patients with 5 treatments each looking into the applicator’s placement in regard to the organs at risk. Motion possibilities for each applicator intra and inter fractionation with their dosimetric implications were covered and measured in regard with their dose variance. The localization immobilization devices used were assessed for the capability to prevent motion before and during the treatment delivery. Results: We focused on the 100% isodose on central axis and a 15 degree displacement due to possible rotation analyzing the dose variations to the bladder and rectum walls. The average dose variation for bladder was 15% of the accepted tolerance, with a minimum variance of 11.1% and a maximum one of 23.14% on the central axis. For the off axis measurements we found an average variation of 16.84% of the accepted tolerance, with a minimum variance of 11.47% and a maximum one of 27.69%. For the rectum we focused on the rectum wall closest to the 120% isodose line. The average dose variation was 19.4%, minimum 11.3% and a maximum of 34.02% from the accepted tolerance values Conclusion: Improved immobilization devices are recommended. For inter-fractionation, localization devices are recommended in place with consistent planning in regards with the initial fraction. Many of the present immobilization devices produced for external radiotherapy can be used to improve the localization of HDR applicators during transportation of the patient and during treatment.

60 APPLIED LIFE SCIENCES↗

SU-F-T-260: Using Portal Image Device for Pre-Treatment QA in Volumetric Modulated Arc Plans with Flattening Filter Free (FFF) Beams

Purpose: To implement and validate a method of using electronic portal image device (EPID) for pre-treatment quality assurance (QA) of volumetric modulated arc therapy (VMAT) plans using flattering filter free (FFF) beams for stereotactic body radiotherapy (SBRT). Methods: On Varian Edge with 6MV FFF beam, open field (from 2×2 cm to 20×20 cm) EPID images were acquired with 200 monitor unit (MU) at the image device to radiation source distance of 150cm. With 10×10 open field and calibration unit (CU) provided by vendor to EPID image pixel, a dose conversion factor was determined by dividing the center dose calculated from the treatment planning system (TPS) to the corresponding CU readout on the image. Water phantom measured beam profile and the output factors for various field sizes were further correlated to those of EPID images. The dose conversion factor and correction factors were then used for converting the portal images to the planner dose distributions of clinical fields. A total of 28 VMAT fields of 14 SBRT plans (8 lung, 2 prostate, 2 liver and 2 spine) were measured. With 10% low threshold cutoff, the delivered dose distributions were compared to the reference doses calculated in water phantom from the TPS. A gamma index analysis was performed for the comparison in percentage dose difference/distance-to-agreement specifications. Results: The EPID device has a linear response to the open fields with increasing MU. For the clinical fields, the gamma indices between the converted EPID dose distributions and the TPS calculated 2D dose distributions were 98.7%±1.1%, 94.0%±3.4% and 70.3%±7.7% for the criteria of 3%/3mm, 2%/2mm and 1%/1mm, respectively. Conclusion: Using a portal image device, a high resolution and high accuracy portal dosimerty was achieved for pre-treatment QA verification for SBRT VMAT plans with FFF beams.

60 APPLIED LIFE SCIENCES↗