Search NASA⌕ Search

SEARCH · Search NASA

Results for “DOSES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,189 records · Page 66

SU-F-I-53: Coded Aperture Coherent Scatter Spectral Imaging of the Breast: A Monte Carlo Evaluation of Absorbed Dose

Purpose: Coherent scatter based imaging has shown improved contrast and molecular specificity over conventional digital mammography however the biological risks have not been quantified due to a lack of accurate information on absorbed dose. This study intends to characterize the dose distribution and average glandular dose from coded aperture coherent scatter spectral imaging of the breast. The dose deposited in the breast from this new diagnostic imaging modality has not yet been quantitatively evaluated. Here, various digitized anthropomorphic phantoms are tested in a Monte Carlo simulation to evaluate the absorbed dose distribution and average glandular dose using clinically feasible scan protocols. Methods: Geant4 Monte Carlo radiation transport simulation software is used to replicate the coded aperture coherent scatter spectral imaging system. Energy sensitive, photon counting detectors are used to characterize the x-ray beam spectra for various imaging protocols. This input spectra is cross-validated with the results from XSPECT, a commercially available application that yields x-ray tube specific spectra for the operating parameters employed. XSPECT is also used to determine the appropriate number of photons emitted per mAs of tube current at a given kVp tube potential. With the implementation of the XCAT digital anthropomorphic breast phantom library, a variety of breast sizes with differing anatomical structure are evaluated. Simulations were performed with and without compression of the breast for dose comparison. Results: Through the Monte Carlo evaluation of a diverse population of breast types imaged under real-world scan conditions, a clinically relevant average glandular dose for this new imaging modality is extrapolated. Conclusion: With access to the physical coherent scatter imaging system used in the simulation, the results of this Monte Carlo study may be used to directly influence the future development of the modality to keep breast dose to a minimum while still maintaining clinically viable image quality.

60 APPLIED LIFE SCIENCES↗

SU-F-J-99: Dose Accumulation and Evaluation in Lung SBRT Among All Phases of Respiration

Purpose: To calculate the total planning dose on lung tumors (GTV) by accumulating the dose received in all respiration phases. Methods: A patient 4D planning CT (phase-binned, from a Siemens Somatom CT) was used to locate the GTV of a lung tumor in all respiratory phases with Pinnacle (v9.10). GTV contours defined in all phases were projected to the reference phase, where the ITV was defined. Centroids were calculated for all the GTV projections. No deformation or rotation was taken into account. The only GTV contour as defined in the reference phase was voxelized to track each voxel individually. We accumulated the absorbed dose in different phases on each voxel. A 3DCRT and a VMAT plan were designed on the reference phase fulfilling the ITV dosimetric requirements, using the 10MV FFF photon model from an Elekta Versa linac. ITV-to-PTV margins were set to 5mm. In-house developed MATLAB code was used for tumor voxeling and dose accumulation, assuming that the dose distribution planned in the reference phase behaved as a “dose-cloud” during patient breathing. Results: We tested the method on a patient 4DCT set of images exhibiting limited tumor motion (<5mm). For the 3DCRT plan, D95 was calculated for the GTV with motion and for the ITV, showing an agreement of 0.04%. For the VMAT plan, we calculated the D95 for every phase as if the GTV in that phase had received the whole treatment. Differences in D95 for all phases are within 1%, and estimate the potential interplay effect during delivery. Conclusion: A method for dose accumulation and assessment was developed that can compare GTV motion with ITV dosage, and estimate the potential interplay effect for VMAT plans. Work in progress includes the incorporation of deformable image registration and 4D CBCT dose calculation for dose reconstruction and assessment during treatment.

60 APPLIED LIFE SCIENCES↗

SU-F-T-46: The Effect of Inter-Seed Attenuation and Tissue Composition in Prostate 125I Brachytherapy Dose Calculations

Purpose: To investigate the difference of dose distributions with/without the effect of inter-seed attenuation and tissue compositions in prostate {sup 125}I brachytherapy dose calculations, using Monte Carlo simulations of Particle and Heavy Ion Transport code System (PHITS). Methods: The dose distributions in {sup 125}I prostate brachytherapy were calculated using PHITS for non-simultaneous and simultaneous alignments of STM1251 sources in water or prostate phantom for six patients. The PHITS input file was created from DICOM-RT file which includes source coordinates and structures for clinical target volume (CTV) and organs at risk (OARs) of urethra and rectum, using in-house Matlab software. Photon and electron cutoff energies were set to 1 keV and 100 MeV, respectively. The dose distributions were calculated with the kerma approximation and the voxel size of 1 × 1 × 1 mm{sup 3}. The number of incident photon was set to be the statistical uncertainty (1σ) of less than 1%. The effect of inter-seed attenuation and prostate tissue compositions was evaluated from dose volume histograms (DVHs) for each structure, by comparing to results of the AAPM TG-43 dose calculation (without the effect of inter-seed attenuation and prostate tissue compositions). Results: The dose reduction due to the inter-seed attenuation by source capsules was approximately 2% for CTV and OARs compared to those of TG-43. In additions, by considering prostate tissue composition, the D{sub 90} and V{sub 100} of CTV reduced by 6% and 1%, respectively. Conclusion: It needs to consider the dose reduction due to the inter-seed attenuation and tissue composition in prostate {sup 125}I brachytherapy dose calculations.

60 APPLIED LIFE SCIENCES↗

Maxine Onsite: Estimating Dose from Chronic Atmospheric Radioactive Releases

Maxine Onsite: Developed to estimate dose to individuals who are working onsite but are not site employees. Follows the methodologies discussed in US NRC Regulatory Guides 1.109 and 1.111 to determine dose from a chronic atmospheric release. Determines the dose given relative air concentrations and deposition concentrations as input. We look at four locations onsite that may be accessed by members of the public. To show compliance with the EPA and DOE public dose limit of 10 mrem/yr, determining who is a member of the public or a worker onsite is necessary. SRS has defined a member of the public for NESHAPS and DOE O 458.1. Maxine Onsite runs on Microsoft Windows Operating System through a Microsoft Excel spreadsheet. Input from the user includes parameters that are variable such as air concentrations, and fixed, such as distance to the receptor and elemental iodine fraction. Maxine Onsite was developed from Maxine which is a program meant to calculate dose to the MEI via three pathways, external, inhalation, and ingestion. Maxine Onsite is meant for looking at the exposure through the external and inhalation pathways only, no local food production onsite. The ways that Maxine Onsite is used to calculate the dose to the MEI includes the following: - Determining the respective air concentration values at each location using distances from the release stack; - Breathing rates for the MEI; - Determining the amount of time the MEI is outside; - Determining the plume travel time. The following relative air and ground deposition values for proper execution of the spreadsheet come from MAXDOSE-SR and are needed to accurately determine the dose to the MEI: relative air concentration, relative air concentration decayed by 2.26 days, relative air concentration decayed and depleted for 8 days, and relative deposition. Test cases were designed, developed, and executed to determine the accuracy of Maxine Onsite, which were verified additionally through hand calculations. Several changes were made for testing, including varying air concentrations, distances, breathing rates, and shielding factors. Each test case was then verified through hand calculations to assure the accuracy of the calculated doses. The results from the test cases, as well as the default parameters, can be used for benchmarking Maxine Onsite in the future. Maxine Onsite performs as expected and produces correct and accurate results at each of the different locations onsite (TRL, B-Area Barracks, SRELCC, and Gunsite 51) for varying test cases. The input required by the user is minimal and includes the results of the dose to the MEI on the first page for ease of access. Future plans for Maxine Onsite include adding in the ingestion pathway and adding in atmospheric dispersion estimates to the spreadsheet.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

The Effect of Realtime Monitoring on Dose Exposure to Staff Within an Interventional Radiology Setting

PurposeThe purpose of this study is to evaluate a new device providing real-time monitoring on radiation exposure during fluoroscopy procedures intending to reduce radiation in an interventional radiology setting.Materials and MethodsIn one interventional suite, a new system providing a real-time radiation dose display and five individual wireless dosimeters were installed. The five dosimeters were worn by the attending, fellow, nurse, technician, and anesthesiologist for every procedure taking place in that suite. During the first 6-week interval the dose display was off (closed phase) and activated thereafter, for a 6-week learning phase (learning phase) and a 10-week open phase (open phase). During these phases, the staff dose and the individual dose for each procedure were recorded from the wireless dosimeter and correlated with the fluoroscopy time. Further subanalysis for dose exposure included diagnostic versus interventional as well as short (<10 min) versus long (>10 min) procedures.ResultsA total of 252 procedures were performed (n = 88 closed phase, n = 50 learning phase, n = 114 open phase). The overall mean staff dose per fluoroscopic minute was 42.79 versus 19.81 µSv/min (p < 0.05) comparing the closed and open phase. Thereby, anesthesiologists were the only individuals attaining a significant dose reduction during open phase 16.9 versus 8.86 µSv/min (p < 0.05). Furthermore, a significant reduction of total staff dose was observed for short 51 % and interventional procedures 45 % (p < 0.05, for both).ConclusionA real-time qualitative display of radiation exposure may reduce team radiation dose. The process may take a few weeks during the learning phase but appears sustained, thereafter.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Comparing Effective Doses During Image-Guided Core Needle Biopsies with Computed Tomography Versus C-Arm Cone Beam CT Using Adult and Pediatric Phantoms

PurposeTo compare the effective doses of needle biopsies based on dose measurements and simulations using adult and pediatric phantoms, between cone beam c-arm CT (CBCT) and CT.MethodEffective doses were calculated and compared based on measurements and Monte Carlo simulations of CT- and CBCT-guided biopsy procedures of the lungs, liver, and kidney using pediatric and adult phantoms.ResultsThe effective doses for pediatric and adult phantoms, using our standard protocols for upper, middle and lower lungs, liver, and kidney biopsies, were significantly lower under CBCT guidance than CT. The average effective dose for a 5-year old for these five biopsies was 0.36 ± 0.05 mSv with the standard CBCT exposure protocols and 2.13 ± 0.26 mSv with CT. The adult average effective dose for the five biopsies was 1.63 ± 0.22 mSv with the standard CBCT protocols and 8.22 ± 1.02 mSv using CT. The CT effective dose was higher than CBCT protocols for child and adult phantoms by 803 and 590 % for upper lung, 639 and 525 % for mid-lung, and 461 and 251 % for lower lung, respectively. Similarly, the effective dose was higher by 691 and 762 % for liver and 513 and 608 % for kidney biopsies.ConclusionsBased on measurements and simulations with pediatric and adult phantoms, radiation effective doses during image-guided needle biopsies of the lung, liver, and kidney are significantly lower with CBCT than with CT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparison of neutron organ and effective dose coefficients for PIMAL stylized phantom in bent postures in standard irradiation geometries

Neutron dose coefficients for standard irradiation geometries have been reported in International Commission on Radiological Protection (ICRP) Publication 116 for the ICRP Publication 110 adult reference phantoms. In the present paper, organ and effective dose coefficients have been calculated for a receptor in both upright and articulated (bent) postures representing more realistic working postures exposed to a mono-energetic neutron radiation field. This work builds upon prior work by Dewji and co-workers comparing upright and bent postures for exposure to mono-energetic photon fields. Simulations were conducted using the Oak Ridge National Laboratory’s articulated stylized adult phantom, “Phantom wIth Moving Arms and Legs” (PIMAL) software package, and the Monte Carlo N-Particle (MCNP) version 6.1.1 radiation transport code. Organ doses were compared for the upright and bent (45° and 90°) phantom postures for neutron energies ranging from 1 × 10 -9 to 20 MeV for the ICRP Publication 116 external exposure geometries—antero-posterior (AP), postero-anterior (PA), and left and right lateral (LLAT, RLAT). Using both male and female phantoms, effective dose coefficients were computed using ICRP Publication 103 methodology. The resulting coefficients for articulated phantoms were compared to those of the upright phantom. Computed organ and effective dose coefficients are discussed as a function of neutron energy, phantom posture, and source irradiation geometry. For example, it is shown here that for the AP and PA irradiation geometries, the differences in the organ coefficients between the upright and bent posture become more pronounced with increasing bending angle. In the AP geometry, the brain dose coefficients are expectedly higher in the bent postures than in the upright posture, while all other organs have lower dose coefficients, with the thyroid showing the greatest difference. Finally and overall, the effective dose estimated for the upright phantom is more conservative than that for the articulated phantom, which may have ramifications in the estimation or reconstruction of radiation doses.

61 RADIATION PROTECTION AND DOSIMETRY↗

Observation of a Dose-Control Relationship for Lung and Liver Tumors After Stereotactic Body Radiation Therapy

Purpose: To determine prognostic factors for local control of primary or metastatic tumors within the lung or liver treated with stereotactic body radiation therapy (SBRT) within a single institution. Methods and Materials: The records of 141 consecutive patients with 246 lesions treated with three-fraction SBRT from Oct 1999 through Aug 2005 were reviewed. Local control was assessed radiographically. Univariate and multivariate analyses were performed to evaluate the influence of the following factors on local control: total dose, expressed as either nominal prescription dose or equivalent uniform dose (EUD); gross tumor volume; primary site; treatment site (lung vs. other); histologic characteristics (adenocarcinoma vs. other); gender; age; and primary vs. metastatic tumor. Results: On univariate analysis, increased dose (either nominal or EUD) and smaller gross tumor volume were significant predictors of higher local control. Lesions treated to a nominal dose of 54 Gy or greater had a 3-year actuarial local control rate of 89.3% compared with 59.0% and 8.1% for those treated to 36-53.9 Gy and less than 36 Gy. On multivariate analysis, only increased nominal dose and EUD retained statistical significance. Treatment was well tolerated; 5.7% of patients experienced Grade 3 or higher toxicity. Conclusions: This large single-institution series suggests a dose-control relationship within the range of SBRT doses applied. Excellent local control rates are achieved with a nominal dose of 54 Gy or greater, corresponding to an EUD greater than 65.3 Gy. These results support the use of aggressive SBRT regimens when durable tumor control is the primary objective.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

In Vivo Dosimetry Using a Linear Mosfet-Array Dosimeter to Determine the Urethra Dose In {sup 125}I Permanent Prostate Implants

Purpose: In vivo dosimetry during brachytherapy of the prostate with {sup 125}I seeds is challenging because of the high dose gradients and low photon energies involved. We present the results of a study using metal-oxide-semiconductor field-effect transistor (MOSFET) dosimeters to evaluate the dose in the urethra after a permanent prostate implantation procedure. Methods and Materials: Phantom measurements were made to validate the measurement technique, determine the measurement accuracy, and define action levels for clinical measurements. Patient measurements were performed with a MOSFET array in the urinary catheter immediately after the implantation procedure. A CT scan was performed, and dose values, calculated by the treatment planning system, were compared to in vivo dose values measured with MOSFET dosimeters. Results: Corrections for temperature dependence of the MOSFET array response and photon attenuation in the catheter on the in vivo dose values are necessary. The overall uncertainty in the measurement procedure, determined in a simulation experiment, is 8.0% (1 SD). In vivo dose values were obtained for 17 patients. In the high-dose region (> 100 Gy), calculated and measured dose values agreed within 1.7% {+-} 10.7% (1 SD). In the low-dose region outside the prostate (< 100 Gy), larger deviations occurred. Conclusions: MOSFET detectors are suitable for in vivo dosimetry during {sup 125}I brachytherapy of prostate cancer. An action level of {+-} 16% (2 SD) for detection of errors in the implantation procedure is achievable after validation of the detector system and measurement conditions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dose Distribution in Bladder and Surrounding Normal Tissues in Relation to Bladder Volume in Conformal Radiotherapy for Bladder Cancer

Purpose: To estimate bladder movements and changes in dose distribution in the bladder and surrounding tissues associated with changes in bladder filling and to estimate the internal treatment margins. Methods and Materials: A total of 16 patients with bladder cancer underwent planning computed tomography scans with 80- and 150-mL bladder volumes. The bladder displacements associated with the change in volume were measured. Each patient had treatment plans constructed for a 'partially empty' (80 mL) and a 'partially full' (150 mL) bladder. An additional plan was constructed for tumor irradiation alone. A subsequent 9 patients underwent sequential weekly computed tomography scanning during radiotherapy to verify the bladder movements and estimate the internal margins. Results: Bladder movements were mainly observed cranially, and the estimated internal margins were nonuniform and largest (>2 cm) anteriorly and cranially. The dose distribution in the bladder worsened if the bladder increased in volume: 70% of patients (11 of 16) would have had bladder underdosed to <95% of the prescribed dose. The dose distribution in the rectum and intestines was better with a 'partially empty' bladder (volume that received >70%, 80%, and 90% of the prescribed dose was 23%, 20%, and 15% for the rectum and 162, 144, 123 cm{sup 3} for the intestines, respectively) than with a 'partially full' bladder (volume that received >70%, 80%, and 90% of the prescribed dose was 28%, 24%, and 18% for the rectum and 180, 158, 136 cm{sup 3} for the intestines, respectively). The change in bladder filling during RT was significant for the dose distribution in the intestines. Tumor irradiation alone was significantly better than whole bladder irradiation in terms of organ sparing. Conclusion: The displacements of the bladder due to volume changes were mainly related to the upper wall. The internal margins should be nonuniform, with the largest margins cranially and anteriorly. The changes in bladder filling during RT could influence the dose distribution in the bladder and intestines. The dose distribution in the rectum and bowel was slightly better with a 'partially empty' than with a 'full' bladder.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

In Vivo Dosimetry With a Linear MOSFET Array to Evaluate the Urethra Dose During Permanent Implant Brachytherapy Using Iodine-125

Purpose: To develop a technique to monitor the dose rate in the urethra during permanent implant brachytherapy using a linear MOSFET array, with sufficient accuracy and without significantly extending the implantation time. Methods and Materials: Phantom measurements were performed to determine the optimal conditions for clinical measurements. In vivo measurements were performed in 5 patients during the {sup 125}I brachytherapy implant procedure. To evaluate if the urethra dose obtained in the operating room with the ultrasound transducer in the rectum and the patient in treatment position is a reference for the total accumulated dose; additional measurements were performed after the implantation procedure, in the recovery room. Results: In vivo measurements during and after the implantation procedure agree very well, illustrating that the ultrasound transducer in the rectum and patient positioning do not influence the measured dose in the urethra. In vivo dose values obtained during the implantation are therefore representative for the total accumulated dose in the urethra. In 5 patients, the dose rates during and after the implantation were below the maximum dose rate of the urethra, using the planned seed distribution. Conclusion: In vivo dosimetry during the implantation, using a MOSFET array, is a feasible technique to evaluate the dose in the urethra during the implantation of {sup 125}I seeds for prostate brachytherapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Relationship Between Pelvic Organ-at-Risk Dose and Clinical Target Volume in Postprostatectomy Patients Receiving Intensity-Modulated Radiotherapy

Purpose: To investigate dose-volume consequences of inclusion of the seminal vesicle (SV) bed in the clinical target volume (CTV) for the rectum and bladder using biological response indices in postprostatectomy patients receiving intensity-modulated radiotherapy (IMRT). Methods and Materials: We studied 10 consecutive patients who underwent prostatectomy for prostate cancer and subsequently received adjuvant or salvage RT to the prostate fossa. The CTV to planning target volume (PTV) expansion was 7 mm, except posterior expansion, which was 5 mm. Two IMRT plans were generated for each patient, including either the prostate fossa alone or the prostate fossa with the SV bed, but identical in all other aspects. Prescription dose was 68.4 Gy in 1.8-Gy fractions prescribed to {>=}95% PTV. Results: With inclusion of the SV bed in the treatment volume, PTV increased and correlated with PTV-bladder and PTV-rectum volume overlap (Spearman {rho} 0.91 and 0.86, respectively; p < 0.05). As a result, the dose delivered to the bladder and rectum was higher (p < 0.05): mean bladder dose increased from 11.3 {+-} 3.5 Gy to 21.2 {+-} 6.6 Gy, whereas mean rectal dose increased from 25.8 {+-} 5.5 Gy to 32.3 {+-} 5.5 Gy. Bladder and rectal equivalent uniform dose correlated with mean bladder and rectal dose. Inclusion of the SV bed in the treatment volume increased rectal normal tissue complication probability from 2.4% to 4.8% (p < 0.01). Conclusions: Inclusion of the SV bed in the CTV in postprostatectomy patients receiving IMRT increases bladder and rectal dose, as well as rectal normal tissue complication probability. The magnitude of PTV-bladder and PTV-rectal volume overlap and subsequent bladder and rectum dose increase will be higher if larger PTV expansion margins are used.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Analysis of Dose at the Site of Second Tumor Formation After Radiotherapy to the Central Nervous System

Purpose: Second tumors are an uncommon complication of multimodality treatment of childhood cancer. The present analysis attempted to correlate the dose received as a component of primary treatment and the site of the eventual development of a second tumor. Methods and Materials: We retrospectively identified 16 patients who had received radiotherapy to sites in the craniospinal axis and subsequently developed a second tumor. We compared the historical fields and port films of the primary treatment with the modern imaging of the second tumor locations. We classified the location of the second tumors as follows: in the boost field; marginal to the boost field, but in a whole-brain field; in a whole-brain field; marginal to the whole brain/primary treatment field; and distant to the field. We divided the dose received into 3 broad categories: high dose (>45 Gy), moderate dose (20-36 Gy), and low dose (<20 Gy). Results: The most common location of the second tumor was in the whole brain field (57%) and in the moderate-dose range (81%). Conclusions: Our data contradict previous publications that suggested that most second tumors develop in tissues that receive a low radiation dose. Almost all the second tumors in our series occurred in tissue within a target volume in the cranium that had received a moderate dose (20-36 Gy). These findings suggest that a major decrease in the brain volume that receives a moderate radiation dose is the only way to substantially decrease the second tumor rate after central nervous system radiotherapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Mild Toxicity and Favorable Prognosis of High-Dose and Extended Involved-Field Intensity-Modulated Radiotherapy for Patients With Early-Stage Nasal NK/T-Cell Lymphoma

Purpose: The value of intensity-modulated radiotherapy (IMRT) for early-stage nasal NK/T-cell lymphoma has not been previously reported. The aim of the present study was to assess the dosimetric parameters, toxicity, and treatment outcomes of patients with nasal NK/T-cell lymphoma. Methods and Materials: Between 2003 and 2008, 42 patients with early-stage nasal NK/T-cell lymphoma underwent definitive high-dose and extended involved-field IMRT with or without combination chemotherapy. The median radiation dose to the primary tumor was 50 Gy. The dose-volume histograms of the target volume and critical normal structures were evaluated in all patients. The locoregional control, overall survival, and progression-free survival were calculated using the Kaplan-Meier method. Results: The average mean dose delivered to the planning target volume was 55.5 Gy. Only 1.3% and 2.5% of the planning target volume received <90% and 95% of the prescribed dose, respectively, indicating excellent planning target volume coverage. The mean dose and average dose to the parotid glands was 15 Gy and 14 Gy, respectively. With a median follow-up time of 27 months, the 2-year locoregional control, overall survival, and progression-free survivalrate was 93%, 78%, and 74%, respectively. No Grade 4 or 5 acute or late toxicity was reported. Conclusions: High-dose and extended involved-field IMRT for patients with early-stage nasal NK/T-cell lymphoma showed favorable locoregional control, overall survival, and progression-free survival, with mild toxicity. The dose constraints of IMRT for the parotid glands can be limited to <20 Gy in these patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Optimizing Normal Tissue Sparing in Ion Therapy Using Calculated Isoeffective Dose for Ion Selection

Purpose: To investigate how the selection of ion type affects the calculated isoeffective dose to the surrounding normal tissue as a function of both normal tissue and target tissue {alpha}/{beta} ratios. Methods and Materials: A microdosimetric biologic dose model was incorporated into a Geant4 simulation of parallel opposed beams of protons, helium, lithium, beryllium, carbon, and neon ions. The beams were constructed to give a homogeneous isoeffective dose to a volume in the center of a water phantom for target tissues covering a range of cobalt equivalent {alpha}/{beta} ratios of 1-20 Gy. Concomitant normal tissue isoeffective doses in the plateau of the ion beam were then compared for different ions across the range of normal tissue and target tissue radiosensitivities for a fixed isoeffective dose to the target tissue. Results: The ion type yielding the optimal normal tissue sparing was highly dependent on the {alpha}/{beta} ratio of both the normal and the target tissue. For carbon ions, the calculated isoeffective dose to normal tissue at a 5-cm depth varied by almost a factor of 5, depending on the {alpha}/{beta} ratios of the normal and target tissue. This ranges from a factor of 2 less than the isoeffective dose of a similar proton treatment to a factor of 2 greater. Conclusions: No single ion is optimal for all treatment scenarios. The heavier ions are superior in cases in which the {alpha}/{beta} ratio of the target tissue is low and the {alpha}/{beta} ratio of normal tissue is high, and protons are superior in the opposite circumstances. Lithium and beryllium appear to offer dose advantages similar to carbon, with a considerably lower normal tissue dose when the {alpha}/{beta} ratio in the target tissue is high and the {alpha}/{beta} ratio in the normal tissue is low.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Do Intermediate Radiation Doses Contribute to Late Rectal Toxicity? An Analysis of Data From Radiation Therapy Oncology Group Protocol 94-06

Purpose: To investigate whether the volumes of rectum exposed to intermediate doses, from 30 to 50 Gy, contribute to the risk of Grade {>=}2 late rectal toxicity among patients with prostate cancer receiving radiotherapy. Methods and Materials: Data from 1009 patients treated on Radiation Therapy Oncology Group protocol 94-06 were analyzed using three approaches. First, the contribution of intermediate doses to a previously published fit of the Lyman-Kutcher-Burman (LKB) normal tissue complication probability (NTCP) model was determined. Next, the extent to which intermediate doses provide additional risk information, after taking the LKB model into account, was investigated. Third, the proportion of rectum receiving doses higher than a threshold, VDose, was computed for doses ranging from 5 to 85 Gy, and a multivariate Cox proportional hazards model was used to determine which of these parameters were significantly associated with time to Grade {>=}2 late rectal toxicity. Results: Doses <60 Gy had no detectable impact on the fit of the LKB model, as expected on the basis of the small estimate of the volume parameter (n = 0.077). Furthermore, there was no detectable difference in late rectal toxicity among cohorts with similar risk estimates from the LKB model but with different volumes of rectum exposed to intermediate doses. The multivariate Cox proportional hazards model selected V75 as the only value of VDose significantly associated with late rectal toxicity. Conclusions: There is no evidence from these data that intermediate doses influence the risk of Grade {>=}2 late rectal toxicity. Instead, the critical doses for this endpoint seem to be {>=}75 Gy. It is hypothesized that cases of Grade {>=}2 late rectal toxicity occurring among patients with V75 less than approximately 12% may be due to a 'background' level of risk, likely due mainly to biological factors.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Algorithms Used in Heterogeneous Dose Calculations Show Systematic Differences as Measured With the Radiological Physics Center's Anthropomorphic Thorax Phantom Used for RTOG Credentialing

Purpose: To determine the impact of treatment planning algorithm on the accuracy of heterogeneous dose calculations in the Radiological Physics Center (RPC) thorax phantom. Methods and Materials: We retrospectively analyzed the results of 304 irradiations of the RPC thorax phantom at 221 different institutions as part of credentialing for Radiation Therapy Oncology Group clinical trials; the irradiations were all done using 6-MV beams. Treatment plans included those for intensity-modulated radiation therapy (IMRT) as well as 3-dimensional conformal therapy (3D-CRT). Heterogeneous plans were developed using Monte Carlo (MC), convolution/superposition (CS), and the anisotropic analytic algorithm (AAA), as well as pencil beam (PB) algorithms. For each plan and delivery, the absolute dose measured in the center of a lung target was compared to the calculated dose, as was the planar dose in 3 orthogonal planes. The difference between measured and calculated dose was examined as a function of planning algorithm as well as use of IMRT. Results: PB algorithms overestimated the dose delivered to the center of the target by 4.9% on average. Surprisingly, CS algorithms and AAA also showed a systematic overestimation of the dose to the center of the target, by 3.7% on average. In contrast, the MC algorithm dose calculations agreed with measurement within 0.6% on average. There was no difference observed between IMRT and 3D CRT calculation accuracy. Conclusion: Unexpectedly, advanced treatment planning systems (those using CS and AAA algorithms) overestimated the dose that was delivered to the lung target. This issue requires attention in terms of heterogeneity calculations and potentially in terms of clinical practice.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Evaluation of High Ipsilateral Subventricular Zone Radiation Therapy Dose in Glioblastoma: A Pooled Analysis

Purpose: Cancer stem cells (CSCs) may play a role in the recurrence of glioblastoma. They are believed to originate from neural stem cells in the subventricular zone (SVZ). Because of their radioresistance, we hypothesized that high doses of radiation (>59.4 Gy) to the SVZ are necessary to control CSCs and improve progression-free survival (PFS) or overall survival (OS) in glioblastoma. Methods and Materials: 173 patients with glioblastoma pooled from 2 academic centers were treated with resection followed by chemoradiation therapy. The SVZ was segmented on computed tomography to calculate radiation doses delivered to the presumptive CSC niches. The relationships between high SVZ doses and PFS and OS were examined using Cox proportional hazards models. Five covariates were included to estimate their impact on PFS or OS: ipsilateral and contralateral SVZ doses, clinical target volume dose, age, and extent of resection. Results: Median PFS and OS were 10.4 and 19.6 months for the cohort. The mean ipsilateral SVZ, contralateral SVZ, and clinical target volume doses were 49.2, 35.2, and 60.1 Gy, respectively. Twenty-one patients who received high ipsilateral SVZ dose (>59.4 Gy) had significantly longer median PFS (12.6 vs 9.9 months, P=.042) and longer OS (25.8 vs 19.2 months, P=.173). On multivariate analysis, high radiation therapy doses to ipsilateral SVZ remained a statistically significant independent predictor of improved PFS but not of OS. The extent of surgery affected both PFS and OS on multivariate analysis. Conclusion: High radiation therapy doses to ipsilateral CSC niches are associated with improved PFS in glioblastoma.

62 RADIOLOGY AND NUCLEAR MEDICINE↗