Search NASA⌕ Search

SEARCH · Search NASA

Results for “ELECTROMAGNETIC INSTRUMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,189 records · Page 66

The Jefferson Lab Eta Factory Experiment and Applications of PbWO4 Calorimeters in Future Experimental Facilities

The goal of the new JLab Eta Factory (JEF) experiment, conducted with the GlueX detector in Hall D at Jefferson Lab, is to perform measurements of various ¿(') decays with a primary focus on rare neutral modes. The experiment’s physics program ranges from precision tests of low-energy QCD to searches for gauge bosons with masses below 1 GeV that could couple the Standard Model (SM) sector to the dark sector. The experiment will collect a high-statistics data sample of ¿(') mesons produced via a beam of tagged photons. The GlueX detector features a large, nearly uniform acceptance for both neutral and charged particles, enabling efficient identification of complex multi-particle final states. To meet the requirements of the JEF experiment, the inner section of the forward lead-glass calorimeter in the GlueX detector has been upgraded with lead tungstate (PbWO4) scintillating crystals. PbWO4 offers exceptional characteristics, such as a small radiation length and Molire radius, and large light yield, that make it ideal for constructing high- granularity, high-resolution, radiation-hard detectors. These properties enable excellent spatial separation and energy resolution of reconstructed electromagnetic showers, establishing PbWO4 as the material of choice for many high-precision experiments. The JEF experiment began data collection in April 2025 and will operate concurrently with the GlueX experiment, whose primary objective is the search for gluonic excitations in the meson spectrum. I will give an overview of the JEF experiment, the GlueX detector, and the feasibility of further upgrades to support future ¿ physics studies. Special attention will be given to the newly constructed PbWO4 scintillating calorimeter and recent advancements in calorimeter instrumentation.

Somov, Alexander↗

Experimental Limit on Nonlinear State-Dependent Terms in Quantum Theory

Linear time evolution is one of the fundamental postulates of quantum theory. Past theoretical attempts to introduce nonlinearity into quantum evolution have violated causality. However, a recent theory has introduced nonlinear state-dependent terms in quantum field theory, preserving causality [D. E. Kaplan and S. Rajendran, Phys. Rev. D 105, 055002 (2022)]. We report the results of an experiment that searches for such terms. Our approach, inspired by the Everett many-worlds interpretation of quantum theory, correlates a binary macroscopic classical voltage with the outcome of a projective measurement of a quantum bit, prepared in a coherent superposition state. Measurement results are recorded in a bit string, which is used to control a voltage switch. Presence of a nonzero voltage reading in cases of no applied voltage is the experimental signature of a nonlinear state-dependent shift of the electromagnetic field operator. We implement blinded measurement and data analysis with three control bit strings. Control of systematic effects is realized by producing one of the control bit strings with a classical random-bit generator. The other two bit strings are generated by measurements performed on a superconducting qubit in an IBM Quantum processor and on a N 15 nuclear spin in a nitrogen-vacancy center in diamond. Our measurements find no evidence for electromagnetic quantum state-dependent nonlinearity. We set a bound on the parameter that quantifies this nonlinearity | ε γ | < 4.7 × 10 - 11 , at 90% confidence level.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

First Annual Progress Report on Transmission of Information by Acoustic Communication along Metal Pathways in Nuclear Facilities

The objective of this project is to develop and demonstrate methods for transmission of information in nuclear facilities by acoustic means along existing in-place metal piping infrastructure. Pipes are omnipresent in a nuclear facility, and penetrate enclosures and partitions, such as the containment building wall. In the envisioned acoustic communication (AC) system, packets of information will be transmitted as guided acoustic waves along pipes. Performance of AC hardware and network protocols for efficient and secure communications under development in this project will be eventually evaluated in a representative nuclear power plant environment. Research efforts in the first year of this project have been focused on identification of appropriate transducers, and evaluation of their performance for information transmission along nuclear-grade metallic pipes. COMSOL computer simulations were performed to study acoustic wave generation, propagation, and attenuation on pipes. An experimental benchtop system was used to evaluate signal attenuation and spectral dispersion using piezo-electric transducers (PZTs) and electromagnetic acoustic transducers (EMATs). Communication protocols under evaluation consisted on-off keying (OOK) signal modulation, in particular amplitude shift keying (ASK) and phase shift keying (PSK). Tradeoffs between signal power and communication data rate were considered for ASK and PSK coding schemes.

42 ENGINEERING↗

Report of METL Mutual Inductance Level Sensor Development for Use in Liquid Metals – FY2023

A robust mutual inductance level sensor (MILS) for use in high temperature liquid metals has been developed at Argonne National Laboratory (ANL). The current design utilizes mineral insulated cables with a 300-series stainless steel sheath, magnesium oxide insulation, and a single copper conductor. Two coils are wrapped on a common core made of a 300-series stainless steel tube. One coil is energized with an alternating current (AC) source, and this electromagnetically couples with the second coil to generate an induced voltage. The voltage is measured to determine the mutual induction between the coils, and the mutual inductance measurement can be used to determine the level of a nearby liquid metal volume. The MILS can be located in an isolating thimble that is fully sealed to a vessel containing liquid metal for ease of maintenance and replacement. When the primary coil is energized with the AC source, the coil not only electromagnetic (EM) couples with the second coil, but also the surrounding liquid metal. The EM coupling with the surrounding liquid metal reduces the EM coupling with the second coil, producing an inverse-linear relationship between liquid metal level and secondary coil voltage. This has all been demonstrated at the Mechanisms Engineering Test Loop (METL) liquid sodium facility at ANL. The most current iteration of the MILS system is the MILS-MK-II. This sensor system has been commissioned in a non-sodium test stand where calibrations were performed using a sodium analog. The calibrations proved to be highly linear and repeatable. The MILS-MK-II has been installed in the METL expansion tank where high temperature sodium tests have been performed. The MILS-MK-II has been calibrated against a known standard at temperature of 300°C, and the calibrations have proved to be highly linear and repeatable. The calibrated MILS-MK-II has been in operation in the METL facility for several thousands of hours at temperatures around 300°C. The experimental data has been used to develop and validate electromagnetic finite element models in COMSOL Multiphysics, and now these models can be used to advance the development of the sensor system. Next steps will include temperature compensation to allow for operation at various temperatures. Additionally, efforts to incorporate a self-calibration methodology are underway.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Biological detector and method

A biological detector includes a conduit for receiving a fluid containing one or more magnetic nanoparticle-labeled, biological objects to be detected and one or more permanent magnets or electromagnet for establishing a low magnetic field in which the conduit is disposed. A microcoil is disposed proximate the conduit for energization at a frequency that permits detection by NMR spectroscopy of whether the one or more magnetically-labeled biological objects is/are present in the fluid.

47 OTHER INSTRUMENTATION↗

Biological detector and method

A biological detector includes a conduit for receiving a fluid containing one or more magnetic nanoparticle-labeled, biological objects to be detected and one or more permanent magnets or electromagnet for establishing a low magnetic field in which the conduit is disposed. A microcoil is disposed proximate the conduit for energization at a frequency that permits detection by NMR spectroscopy of whether the one or more magnetically-labeled biological objects is/are present in the fluid.

47 OTHER INSTRUMENTATION↗

Biological detector and method

A biological detector includes a conduit for receiving a fluid containing one or more magnetic nanoparticle-labeled, biological objects to be detected and one or more permanent magnets or electromagnet for establishing a low magnetic field in which the conduit is disposed. A microcoil is disposed proximate the conduit for energization at a frequency that permits detection by NMR spectroscopy of whether the one or more magnetically-labeled biological objects is/are present in the fluid.

47 OTHER INSTRUMENTATION↗

Orchestrating Spontaneous Emission With Metasurfaces: Recent Advances in Engineering Thermal, Luminescent, and Quantum Emissions

Metasurfaces have emerged as powerful tools for controlling spontaneous emission, offering unprecedented control over light-matter interactions at sub-wavelength scales. While metasurfaces are traditionally utilized for shaping coherent electromagnetic waves, they have recently extended their capabilities to control incoherent or spontaneous emission. This examines review how metasurfaces can enhance and precisely control properties of thermal, luminescent, and quantum emission. In thermal emission, metasurfaces enable control over spatial, temporal, and spin coherence, offering new possibilities for applications such as energy harvesting, radiative cooling and heat assisted ranging and detection. For luminescent emission, metasurfaces significantly improve emission rates, quantum efficiency, and directionality, driving innovations in lighting and display technologies. For controlling quantized spontaneous emission, metasurfaces are instrumental in enhancing single-photon sources and enabling novel functionalities in quantum states through photon-pair generation, which is vital for quantum communication, meteorology, and computing. Here, despite these advancements several challenges to increase the operational bandwidths, accelerate and develop simulation strategies, and fabrication complexities persist. Emerging trends are also discussed, such as dynamic metasurfaces and their integration with nanophotonic platforms, which could further expand the capabilities of light-emitting metasurfaces.

Luminescence↗

Transition nucleon resonance electrocouplings from CLAS data on {pi}{sup +}{pi}{sup -}p electroproduction off protons

Electrocouplings of excited proton states with masses less than 1.8 GeV were determined for the first time from the CLAS data on {pi}{sup +}{pi}{sup -}p electroproduction at photon virtualities Q{sup 2}<1.5 GeV{sup 2}. Electrocouplings were obtained from a combined fit of all available observables within the framework of a phenomenological reaction model.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Authentication of Electromagnetic Interference Removal in Johnson Noise Thermometry

This report summarizes the testing performed offsite at the TVA Kingston Fossil Plant (KFP). This location is selected as a valid offsite test facility because the environment is very similar to the expected industrial nuclear power plant environment. This report will discuss the EMI discovered in the environment, the removal technique validity, and results from the measurements.

47 OTHER INSTRUMENTATION↗

Scalable single-mode surface-emitting laser via open-Dirac singularities

Single-aperture cavities are a key component of lasers that are instrumental for the amplification and emission of a single light mode. However, the appearance of high-order transverse modes as the size of the cavities increases has frustrated efforts to scale-up cavities while preserving single-mode operation since the invention of the laser six decades ago. A suitable physical mechanism that allows single-mode lasing irrespective of the cavity size-a 'scale invariant' cavity or laser-has not been identified yet. Here we propose and demonstrate experimentally that open-Dirac electromagnetic cavities with linear dispersion-which in our devices are realized by a truncated photonic crystal arranged in a hexagonal pattern-exhibit unconventional scaling of losses in reciprocal space, leading to single-mode lasing that is maintained as the cavity is scaled up in size. The physical origin of this phenomenon lies in the convergence of the complex part of the free spectral range in open-Dirac cavities towards a constant governed by the loss rates of distinct Bloch bands, whereas for common cavities it converges to zero as the size grows, leading to inevitable multimode emission. An unconventional flat-envelope fundamental mode locks all unit cells in the cavity in phase, leading to single-mode lasing. We name such sources Berkeley surface-emitting lasers (BerkSELs) and demonstrate that their far-field corresponds to a topological singularity of charge two, in agreement with our theory. Open-Dirac cavities unlock avenues for light-matter interaction and cavity quantum electrodynamics.

42 ENGINEERING↗

Positrons and Electrons at HERA and HERMES

The HERA electron-proton storage ring at DESY, Hamburg, provided a unique laboratory for the collection of data in deep-inelastic charged lepton-proton scattering at a center-of-mass energy of about 7 GeV for the fixed-target experiment HERMES and at 318 GeV for the collider experiments ZEUS and Hl. HERA could be operated with both electrons and positrons. The ability of the lepton beam to polarize itself was exploited.Data taken with the HERMES spectrometer on unpolarized and transversely polarized gaseous targets are presented. Two examples involving interference processes are chosen that are sensitive to the beam charge: the measurement of azimuthal asymmtries in deeply-virtual COMPTON scattering and the search for a two-photon exchange signal at HERMES.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Combined in-beam electron and {gamma}-ray spectroscopy of {sup 184,186}Hg

By exploiting the SAGE spectrometer a simultaneous measurement of conversion electrons and {gamma} rays emitted in the de-excitation of excited levels in the neutron-deficient nuclei {sup 184,186}Hg was performed. The light Hg isotopes under investigation were produced using the 4n channels of the fusion-evaporation reactions of {sup 40}Ar and {sup 148,150}Sm. The measured K- and L-conversion electron ratios confirmed the stretched E2 nature of several transitions of the yrast bands in {sup 184,186}Hg. Additional information on the E0 component of the 2{sub 2}{sup +}{yields}2{sub 1}{sup +} transition in {sup 186}Hg was obtained.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Resolving femtosecond photoinduced energy flow: capture of nonadiabatic reaction pathway topography and wavepacket dynamics from photoexcitation through the conical intersection seam (Final Technical Report)

The dynamics that take place within just tens to hundreds of femtoseconds following the absorption of light by a molecule can play a critical role in how the absorbed energy is directed, allowing it to be used for a specific function or dissipated harmlessly. The form of chemical change that occurs rapidly in these molecules is called a “nonadiabatic electronic transition.” Such transitions are known to mediate energy flow in natural biological systems such as the ultraviolet photoprotection mechanism of DNA and the first step of the human vision response. Understanding how these mechanisms work precisely may help scientists achieve controlled manipulation of solar energy or optical control of a wide range of energy management functions in artificial systems. Experimental methods, however, have not yet allowed a precisely resolved and complete measurement of nonadiabatic electronic transitions. This constitutes a major obstacle to progress in the field. For progress to occur that would inform a wide body of research aiming to efficiently harness the energy of light for practical purposes, it is especially important to benchmark computational models of the molecules undergoing these rapid changes with experimental measurements, in order to learn which models are accurate. With Dept. of Energy funding, we have made strong progress towards establishing a new optical method for experimentally detecting the full nonadiabatic electronic transition. This requires having coordinated pulses of light covering the visible through the mid-infrared range of the electromagnetic spectrum that last only ten femtoseconds. We have developed a new, relatively simple approach for generating such pulses of laser light, and have incorporated them into a time-resolved spectrometer for measuring rapid changes in molecules. These tools can provide the greater precision and new types of data that are needed to benchmark computational models of molecular change and thus to make progress in the field. Our tools were tested on graphene, an excellent solid-state sample for verifying the capabilities and limitations of our instrumentation. The investment made in these tools by the Dept. of Energy Office of Science will allow new fundamental scientific understanding of energy dynamics in molecules in future studies.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A Standard Siren Measurement of the Hubble Constant Using Gravitational-wave Events from the First Three LIGO/Virgo Observing Runs and the DESI Legacy Survey

We present a new constraint on the Hubble constant H 0 using a sample of well-localized gravitational-wave (GW) events detected during the first three LIGO/Virgo observing runs as dark standard sirens. In the case of dark standard sirens, a unique host galaxy is not identified, and the redshift information comes from the distribution of potential host galaxies. From the third LIGO/Virgo observing run detections, we add the asymmetric-mass binary black hole GW190412 and the high-confidence GW candidates S191204r, S200129m, and S200311bg to the sample of dark standard sirens analyzed in Palmese et al. Our sample contains the top 20% (based on localization) GW events and candidates to date with significant coverage by the Dark Energy Spectroscopic Instrument Legacy Survey. We combine the H 0 posterior for eight dark siren events, finding H 0 = $79.8^{+19.1}_{-12.8}$ km s -1 Mpc -1 (68% highest density interval) for a prior in H 0 uniform between [20, 140] km s -1 Mpc -1 . This result shows that a combination of eight well-localized dark sirens combined with an appropriate galaxy catalog is able to provide an H 0 constraint that is competitive (~20% versus 18% precision) with a single bright standard siren analysis (i.e., assuming the electromagnetic counterpart) using GW170817. When combining the posterior with that from GW170817, we obtain H 0 = $72.77^{+11.0}_{-7.55}$ km s -1 Mpc -1 . This result is broadly consistent with recent H 0 estimates from both the cosmic microwave background and supernovae.

79 ASTRONOMY AND ASTROPHYSICS↗

Photon Activation Analysis Of Light Elements Using 'Non-Gamma' Radiation Spectroscopy - The Instrumental Determination Of Phosphorus

Unlike metal determinations the analysis of light elements (e.g., carbon, oxygen, phosphorus) is frequently problematic, in particular if analysed instrumentally. In photon activation analysis (PAA) the respective activation products do not emit gamma radiation in the most cases. Usually, annihilation quanta counting and subsequent decay curve analysis have been used for determinations of C, N, O, and F. However, radiochemical separation of the respective radioisotopes mostly is indispensable. For several reasons, some of the light elements cannot be analysed following this procedure, e.g. phosphorus. In this contribution the instrumental PAA of phosphorus in organic matrix by activation with bremsstrahlung of an electron linear accelerator and subsequent beta spectroscopy is described. The accuracy of the results was excellent as obtained by analysis of a BCR Reference Material.

07 ISOTOPE AND RADIATION SOURCES↗

Very Forward Calorimetry at the LHC--Recent results from ATLAS

We present first results from the ATLAS Zero Degree Calorimeters (ZDC) based on 7 TeV pp collision data recorded in 2010. The ZDC coverage of {+-}{approx}350 {mu}rad about the forward direction makes possible the measurement of neutral particles (primarily {pi}{sup 0}'s and neutrons) over the kinematic region x{sub F} > or approx. 0.1 and out to p{sub T} < or approx. 1.2 GeV/c at large x{sub F}. The ATLAS ZDC is unique in that it provides a complete image of both electromagnetic and hadronic showers. This is illustrated with the reconstruction of {pi}{sup 0}'s with energies of 0.7-3.5 TeV. We also discuss the waveform reconstruction algorithm which has allowed good time-of-flight resolution on leading neutrons emerging from the collisions despite the sparse (40 MHz) sampling of the calorimeter signals used.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Infrared nanoantenna apparatus and method for the manufacture thereof

An exemplary embodiment of the present invention is a photodetector comprising a semiconductor body, a periodically patterned metal nanoantenna disposed on a surface of the semiconductor body, and at least one electrode separate from the nanoantenna. The semiconductor body comprises an active layer in sufficient proximity to the nanoantenna for plasmonic coupling thereto. The nanoantenna is dimensioned to absorb electromagnetic radiation in at least some wavelengths not more than 12 .mu.m that are effective for plasmonic coupling into the active layer. The electrode is part of an electrode arrangement for obtaining a photovoltage or photocurrent in operation under appropriate stimulation.

47 OTHER INSTRUMENTATION↗