Search NASA⌕ Search

SEARCH · Search NASA

Results for “EXTRAPOLATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,189 records · Page 66

Ultrahigh energy predictions of proton-air cross sections from accelerator data: An update

At {radical}(s)=57{+-}7 TeV, the Pierre Auger Observatory (PAO) measured the p-air inelastic production cross section, {sigma}{sub p-air}{sup prod}=475{+-}22(stat){+-}{sub 15}{sup 20}(syst) mb, assuming a proton cosmic ray beam with a 25% helium contamination. From a Glauber calculation, they found the inelastic pp cross section, {sigma}{sub inel}=90{+-}7(stat){+-}{sub 11}{sup 9}(syst){+-}1.5(Glaub) mb. Our parameterization of pp and pp total cross sections, {sigma}{sub tot}, using analyticity constraints and unitarity gives accurate extrapolations to ultrahigh energies, and after using a Glauber calculation, accurate predictions for {sigma}{sub p-air}{sup prod}. We find (i) a pp total cross section, {sigma}{sub tot}=133.4{+-}1.6 mb and (ii) {sigma}{sub p-air}{sup prod}=483{+-}3 mb, independently determining a 19% helium contamination. Using our 57 TeV value for pp {sigma}{sub tot}[M. M. Block and F. Halzen, arXiv:1109-2041], we find a pp inelastic cross section, {sigma}{sub inel}=92.9{+-}1.6 mb, agreeing with POA.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Mass of the H Dibaryon

Recent lattice QCD calculations have reported evidence for the existence of a bound state with strangeness -2 and baryon number 2 at quark masses somewhat higher than the physical values. By developing a description of the dependence of this binding energy on the up, down and strange quark masses that allows a controlled chiral extrapolation, we explore the hypothesis that this state is to be identified with the H dibaryon. Taking as input the recent results of the HAL and NPLQCD Collaborations, we show that the H dibaryon is likely to be unbound by 13{+-}14 MeV at the physical point.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Crystallization and preliminary X-ray diffraction analysis of Sfh3, a member of the Sec14 protein superfamily

Sec14 is the major phosphatidylinositol (PtdIns)/phosphatidylcholine (PtdCho) transfer protein in the yeast Saccharomyces cerevisiae and is the founding member of the Sec14 protein superfamily. Recent functional data suggest that Sec14 functions as a nanoreactor for PtdCho-regulated presentation of PtdIns to PtdIns kinase to affect membrane trafficking. Extrapolation of this concept to other members of the Sec14 superfamily suggests a mechanism by which a comprehensive cohort of Sec14-like nanoreactors sense correspondingly diverse pools of lipid metabolites. In turn, metabolic information is translated to signaling circuits driven by phosphoinositide metabolism. Sfh3, one of five Sec14 homologs in yeast, exhibits several interesting functional features, including its unique localization to lipid particles and microsomes. This localization forecasts novel regulatory interfaces between neutral lipid metabolism and phosphoinositide signaling. To launch a detailed structural and functional characterization of Sfh3, the recombinant protein was purified to homogeneity, diffraction-quality crystals were produced and a native X-ray data set was collected to 2.2 {angstrom} resolution. To aid in phasing, SAD X-ray diffraction data were collected to 1.93 {angstrom} resolution from an SeMet-labeled crystal at the Southeast Regional Collaborative Access Team at the Advanced Photon Source. Here, the cloning and purification of Sfh3 and the preliminary diffraction of Sfh3 crystals are reported, enabling structural analyses that are expected to reveal novel principles governing ligand binding and functional specificity for Sec14-superfamily proteins.

43 PARTICLE ACCELERATORS↗

Assessment of Accelerated Stress Testing Data for Silicon Photovoltaics Using Tensor Decomposition Methods

In this work, we examine the use of high-order tensor decompositions to analyze degradation pathways emerging from accelerated stress testing of silicon photovoltaic (PV) modules. Matrix-based decompositions are powerful tools for studying two-dimensional data arrays and form the foundation of a host of classical data analysis techniques. Tensors are high-order extrapolations of matrices that are able to account for more parameter dimensions, and a variety of tensor decomposition methods have been developed that similarly seek to extend insights from matrix decompositions to higher dimensions. Applying and interpreting tensor decomposition methods to sequences of PV module image data, we seek to uncover and isolate different degradation modes occurring from accelerated stress testing procedures. Further, we consider the contributions of different modes to PV module performance degradations.

data analysis↗

Connect the Dots: In Situ 4-D Seismic Monitoring of CO 2 Storage With Spatio-Temporal CNNs

4-D seismic imaging has been widely used in CO 2 sequestration projects to monitor the fluid flow in the volumetric subsurface region that is not sampled by wells. Ideally, real-time monitoring and near-future forecasting would provide site operators with great insights to understand the dynamics of the subsurface reservoir and assess any potential risks. However, due to obstacles such as high deployment cost, availability of acquisition equipment, exclusion zones around surface structures, only very sparse seismic imaging data can be obtained during monitoring. That leads to an unavoidable and growing knowledge gap over time. The operator needs to understand the fluid flow throughout the project lifetime and the seismic data are only available at a limited number of times. This is insufficient for understanding reservoir behavior. To overcome those challenges, we have developed spatio-temporal neural-network-based models that can produce high-fidelity interpolated or extrapolated images effectively and efficiently. Specifically, our models are built on an autoencoder, and incorporate the long short-term memory (LSTM) structure with a new loss function regularized by optical flow. We validate the performance of our models using real 4-D post-stack seismic imaging data acquired at the Sleipner CO 2 sequestration field. We employ two different strategies in evaluating our models. Numerically, we compare our models with different baseline approaches using classic pixel-based metrics. We also conduct a blind survey and collect a total of 20 responses from domain experts to evaluate the quality of data generated by our models. Finally, via both numerical and expert evaluation, we conclude that our models can produce high-quality 2-D/3-D seismic imaging data at a reasonable cost, offering the possibility of real-time monitoring or even near-future forecasting of the CO 2 storage reservoir.

4-D seismic imaging↗

LOGISTIC FUNCTION PROFILE FIT: A least-squares program for fitting interface profiles to an extended logistic function

The extended logistic function provides a physically reasonable description of interfaces such as depth profiles or line scans of surface topological or compositional features. It describes these interfaces with the minimum number of parameters, namely, position, width, and asymmetry. Logistic Function Profile Fit (LFPF) is a robust, least-squares fitting program in which the nonlinear extended logistic function is linearized by a Taylor series expansion (equivalent to a Newton-Raphson approach) with no apparent introduction of bias in the analysis. The program provides reliable confidence limits for the parameters when systematic errors are minimal and provides a display of the residuals from the fit for the detection of systematic errors. The program will aid researchers in applying ASTM E1636-10, 'Standard practice for analytically describing sputter-depth-profile and linescan-profile data by an extended logistic function,' and may also prove useful in applying ISO 18516: 2006, 'Surface chemical analysis-Auger electron spectroscopy and x-ray photoelectron spectroscopy-determination of lateral resolution.' Examples are given of LFPF fits to a secondary ion mass spectrometry depth profile, an Auger surface line scan, and synthetic data generated to exhibit known systematic errors for examining the significance of such errors to the extrapolation of partial profiles.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dose calculation for photon-emitting brachytherapy sources with average energy higher than 50 keV: Report of the AAPM and ESTRO

Purpose: Recommendations of the American Association of Physicists in Medicine (AAPM) and the European Society for Radiotherapy and Oncology (ESTRO) on dose calculations for high-energy (average energy higher than 50 keV) photon-emitting brachytherapy sources are presented, including the physical characteristics of specific {sup 192}Ir, {sup 137}Cs, and {sup 60}Co source models. Methods: This report has been prepared by the High Energy Brachytherapy Source Dosimetry (HEBD) Working Group. This report includes considerations in the application of the TG-43U1 formalism to high-energy photon-emitting sources with particular attention to phantom size effects, interpolation accuracy dependence on dose calculation grid size, and dosimetry parameter dependence on source active length. Results: Consensus datasets for commercially available high-energy photon sources are provided, along with recommended methods for evaluating these datasets. Recommendations on dosimetry characterization methods, mainly using experimental procedures and Monte Carlo, are established and discussed. Also included are methodological recommendations on detector choice, detector energy response characterization and phantom materials, and measurement specification methodology. Uncertainty analyses are discussed and recommendations for high-energy sources without consensus datasets are given. Conclusions: Recommended consensus datasets for high-energy sources have been derived for sources that were commercially available as of January 2010. Data are presented according to the AAPM TG-43U1 formalism, with modified interpolation and extrapolation techniques of the AAPM TG-43U1S1 report for the 2D anisotropy function and radial dose function.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-E-T-104: An Examination of Dose in the Buildup and Build-Down Regions

Purpose: To examine dose in the buildup and build-down regions and compare measurements made with various models and dosimeters Methods: Dose was examined in a 30×30cm {sup 2} phantom of water-equivalent plastic with 10cm of backscatter for various field sizes. Examination was performed with radiochromic film and optically-stimulated-luminescent-dosimeter (OSLD) chips, and compared against a plane-parallel chamber with a correction factor applied to approximate the response of an extrapolation chamber. For the build-down region, a correction factor to account for table absorption and chamber orientation in the posterior-anterior direction was applied. The measurement depths used for the film were halfway through their sensitive volumes, and a polynomial best fit curve was used to determine the dose to their surfaces. This chamber was also compared with the dose expected in a clinical kernel-based computer model, and a clinical Boltzmann-transport-equation-based (BTE) computer model. The two models were also compared against each other for cases with air gaps in the buildup region. Results: Within 3mm, all dosimeters and models agreed with the chamber within 10% for all field sizes. At the entrance surface, film differed in comparison with the chamber from +90% to +15%, the BTE-model by +140 to +3%, and the kernel-based model by +20% to −25%, decreasing with increasing field size. At the exit surface, film differed in comparison with the chamber from −10% to −15%, the BTE-model by −53% to −50%, the kernel-based model by −55% to −57%, mostly independent of field size. Conclusion: The largest differences compared with the chamber were found at the surface for all field sizes. Differences decreased with increasing field size and increasing depth in phantom. Air gaps in the buildup region cause dose buildup to occur again post-gap, but the effect decreases with increasing phantom thickness prior to the gap.

60 APPLIED LIFE SCIENCES↗

Clinical introduction of image lag correction for a cone beam CT system

Purpose: Image lag in the flat-panel detector used for Linac integrated cone beam computed tomography (CBCT) has a degrading effect on CBCT image quality. The most prominent visible artifact is the presence of bright semicircular structure in the transverse view of the scans, known also as radar artifact. Several correction strategies have been proposed, but until now the clinical introduction of such corrections remains unreported. In November 2013, the authors have clinically implemented a previously proposed image lag correction on all of their machines at their main site in Amsterdam. The purpose of this study was to retrospectively evaluate the effect of the correction on the quality of CBCT images and evaluate the required calibration frequency. Methods: Image lag was measured in five clinical CBCT systems (Elekta Synergy 4.6) using an in-house developed beam interrupting device that stops the x-ray beam midway through the data acquisition of an unattenuated beam for calibration. A triple exponential falling edge response was fitted to the measured data and used to correct image lag from projection images with an infinite response. This filter, including an extrapolation for saturated pixels, was incorporated in the authors’ in-house developed clinical CBCT reconstruction software. To investigate the short-term stability of the lag and associated parameters, a series of five image lag measurement over a period of three months was performed. For quantitative analysis, the authors have retrospectively selected ten patients treated in the pelvic region. The apparent contrast was quantified in polar coordinates for scans reconstructed using the parameters obtained from different dates with and without saturation handling. Results: Visually, the radar artifact was minimal in scans reconstructed using image lag correction especially when saturation handling was used. In patient imaging, there was a significant reduction of the apparent contrast from 43 ± 16.7 to 15.5 ± 11.9 HU without the saturation handling and to 9.6 ± 12.1 HU with the saturation handling, depending on the date of the calibration. The image lag correction parameters were stable over a period of 3 months. The computational load was increased by approximately 10%, not endangering the fast in-line reconstruction. Conclusions: The lag correction was successfully implemented clinically and removed most image lag artifacts thus improving the image quality. Image lag correction parameters were stable for 3 months indicating low frequency of calibration requirements.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-C-206-07: A Practical Sparse View Ultra-Low Dose CT Acquisition Scheme for PET Attenuation Correction in the Extended Scan Field-Of-View

Purpose: To further reduce CT dose, a practical sparse-view acquisition scheme is proposed to provide the same attenuation estimation as higher dose for PET imaging in the extended scan field-of-view. Methods: CT scans are often used for PET attenuation correction and can be acquired at very low CT radiation dose. Low dose techniques often employ low tube voltage/current accompanied with a smooth filter before backprojection to reduce CT image noise. These techniques can introduce bias in the conversion from HU to attenuation values, especially in the extended CT scan field-of-view (FOV). In this work, we propose an ultra-low dose CT technique for PET attenuation correction based on sparse-view acquisition. That is, instead of an acquisition of full amount of views, only a fraction of views are acquired. We tested this technique on a 64-slice GE CT scanner using multiple phantoms. CT scan FOV truncation completion was performed based on the published water-cylinder extrapolation algorithm. A number of continuous views per rotation: 984 (full), 246, 123, 82 and 62 have been tested, corresponding to a CT dose reduction of none, 4x, 8x, 12x and 16x. We also simulated sparse-view acquisition by skipping views from the fully-acquired view data. Results: FBP reconstruction with Q. AC filter on reduced views in the full extended scan field-of-view possesses similar image quality to the reconstruction on acquired full view data. The results showed a further potential for dose reduction compared to the full acquisition, without sacrificing any significant attenuation support to the PET. Conclusion: With the proposed sparse-view method, one can potential achieve at least 2x more CT dose reduction compared to the current Ultra-Low Dose (ULD) PET/CT protocol. A pre-scan based dose modulation scheme can be combined with the above sparse-view approaches, which can even further reduce the CT scan dose during a PET/CT exam.

60 APPLIED LIFE SCIENCES↗

SU-D-204-03: Comparison of Patient Positioning Methods Through Modeling of Acute Rectal Toxicity in Intensity Modulated Radiation Therapy for Prostate Cancer. Does Quality of Data Matter More Than the Quantity?

Purpose: To determine if differences in patient positioning methods have an impact on the incidence and modeling of grade >=2 acute rectal toxicity in prostate cancer patients who were treated with Intensity Modulated Radiation Therapy (IMRT). Methods: We compared two databases of patients treated with radiation therapy for prostate cancer: a database of 79 patients who were treated with 7 field IMRT and daily image guided positioning based on implanted gold markers (IGRTdb), and a database of 302 patients who were treated with 5 field IMRT and daily positioning using a trans-abdominal ultrasound system (USdb). Complete planning dosimetry was available for IGRTdb patients while limited planning dosimetry, recorded at the time of planning, was available for USdb patients. We fit Lyman-Kutcher-Burman (LKB) model to IGRTdb only, and Univariate Logistic Regression (ULR) NTCP model to both databases. We perform Receiver Operating Characteristics analysis to determine the predictive power of NTCP models. Results: The incidence of grade >= 2 acute rectal toxicity in IGRTdb was 20%, while the incidence in USdb was 54%. Fits of both LKB and ULR models yielded predictive NTCP models for IGRTdb patients with Area Under the Curve (AUC) in the 0.63 – 0.67 range. Extrapolation of the ULR model from IGRTdb to planning dosimetry in USdb predicts that the incidence of acute rectal toxicity in USdb should not exceed 40%. Fits of the ULR model to the USdb do not yield predictive NTCP models and their AUC is consistent with AUC = 0.5. Conclusion: Accuracy of a patient positioning system affects clinically observed toxicity rates and the quality of NTCP models that can be derived from toxicity data. Poor correlation between planned and clinically delivered dosimetry may lead to erroneous or poorly performing NTCP models, even if the number of patients in a database is large.

60 APPLIED LIFE SCIENCES↗

Specific features of magnetic phase diagram of an MnSi helimagnet

Magnetization curves of MnSi single crystals have been measured in a range of temperatures T = 5.5-35 K and magnetic field strengths H {<=} 11 kOe for H Parallel-To [1 1 1], [0 0 1], and [1 1 0]. Special attention has been paid to the temperature interval near T{sub N} = 28.8 K, where MnSi exhibits a transition to the state with a long-period helical magnetic structure. Some new features in the magnetic behavior of MnSi have been found. In particular, in an intermediate temperature region above the transition (28.8 K = T{sub N} {<=} T < 31.5 K), the dM(H)/dH curves exhibit anomalies that are not characteristic of the typical paramagnetic state. It is established that the line of the characteristic field H*(T) of this anomaly is a natural extrapolation of the temperature dependence of the field of the transition from a conical phase to an induced ferromagnetic phase observed at T < T{sub N}. It is concluded that the properties of MnSi in the indicated intermediate region are related to and governed by those of the conical phase (rather than of the A phase). Based on these data, magnetic phase diagrams of MnSi for H Parallel-To [1 1 1], [0 0 1], and [1 1 0] are plotted and compared to diagrams obtained earlier by other methods.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

How large is 'large N{sub c}' for nuclear matter?

We argue that a so far neglected dimensionless scale, the number of neighbors in a closely packed system, is relevant for the convergence of the large-N{sub c} expansion at high chemical potential. It is only when the number of colors is large w.r.t. this new scale ({approx} O(10)) that a convergent large-N{sub c} limit is reached. This provides an explanation as to why the large-N{sub c} expansion, qualitatively successful in vacuum QCD, fails to describe high baryo-chemical potential systems, such as nuclear matter. It also means that phenomenological claims about high-density matter based on large-N{sub c} extrapolations should be treated with caution. This work is based on [1].

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Contribution of the Δ-isobar excitation mechanism to the pp → {pp}{sub s} π{sup 0} reaction

The differential cross section of the reaction pp → {pp}{sub s} π{sup 0}, where {pp}{sub s} is the proton pair in the {sup 1}S{sub 0} state at a small excitation energy E{sub pp} < 3 MeV, is calculated using the box diagram with the excitation of the Δ-isobar. The model demonstrates a clear bump observed in the experimental data at the beam energy of ∼0.6 GeV and the zero diproton outgoing angle; however, its absolute value strongly depends on the off-shell extrapolation of the πNΔ vertex factor and underestimates the data.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Composition and optical properties of amorphous a-SiO{sub x}:H films with silicon nanoclusters

The phase composition and optical properties of hydrogenated amorphous films of silicon suboxide (a-SiO{sub x}:H) with silicon nanoclusters are studied. Ultrasoft X-ray emission spectroscopy show that silicon- suboxide films with various oxidation states and various amorphous silicon-cluster contents can be grown using dc discharge modulation. In films with an ncl-Si content of ∼50%, the optical-absorption edge is observed, whose extrapolation yields an optical band gap estimate of ∼3.2–3.3 eV. In the visible region, rather intense photoluminescence bands are observed, whose peak positions indicate the formation of silicon nanoclusters 2.5–4.7 nm in size in these films, depending on the film composition.

36 MATERIALS SCIENCE↗

Thermal stability of hydrogenated small-diameter carbon nanotubes

The initial stage of hydrogen desorption from fully hydrogenated carbon nanotubes (3.0) and (2.2) is numerically studied by the molecular dynamics method. The temperature dependence of the desorption rate is directly determined at T = 1800–2500 K. The characteristic desorption times are determined at temperatures outside this range by extrapolation. It is shown that hydrogen desorption leads to the appearance of electronic states in the band gap.

36 MATERIALS SCIENCE↗

Size Dependence of the Melting Point of Silicon Nanoparticles: Molecular Dynamics and Thermodynamic Simulation

The size dependence of the melting point of Si nanoparticles is investigated using molecular dynamics and thermodynamic simulation based on the Thomson’s formula. The atomistic modeling data obtained using the Stillinger–Weber potential agree with the results reported by other authors and thermodynamic-simulation data and predict a decrease in the melting point T{sub m} of Si nanoparticles with an increase in their reciprocal radius R{sup –1} according to linear law. The available experimental data predict lower T{sub m} values, including the limiting value T{sub m}{sup (∞)}, which corresponds to the linear extrapolation of experimental points to R{sup –1} → 0 (to the radius R → ∞); the underestimation is 200–300 K as compared with the reference melting point of silicon (1688 K). It is concluded that the molecular-dynamics data on T{sub m}(R{sup –1}) obtained using the Stillinger–Weber potential are more adequate than the available experimental data.

74 ATOMIC AND MOLECULAR PHYSICS↗

Comparative Iron Oxide Nanoparticle Cellular Dosimetry and Response in Mice by the Inhalation and Liquid Cell Culture Exposure Routes

testing the rapidly growing number of nanomaterials requires large scale use of in vitro systems under the presumption that these systems are sufficiently predictive or descriptive of responses in in vivo systems for effective use in hazard ranking. We hypothesized that improved relationships between in vitro and in vivo models of experimental toxicology for nanomaterials would result from placing response data in vitro and in vivo on the same dose scale, the amount of material associated with cells (target cell dose). Methods: Balb/c mice were exposed nose-only to an aerosol of 12.8 nm (68.6 nm CMD, 19.9 mg/m3, 4 hours) super paramagnetic iron oxide particles, target cell doses were calculated and biomarkers of response anchored with histological evidence were identified by global transcriptomics. Representative murine epithelial and macrophage cell types were exposed in vitro to the same material in liquid suspension for four hours and levels nanoparticle regulated cytokine transcripts identified in vivo were quantified as a function of measured nanoparticle cellular dose. Results. Target tissue doses of 0.009-0.4 μg SPIO/cm2 lung led to an inflammatory response in the alveolar region characterized by interstitial inflammation and macrophage infiltration. In vitro, higher target tissue doses of ~1.2-4 μg SPIO/ cm2 of cells were required to induce transcriptional regulation of markers of inflammation, CXCL2 CCL3, in C10 lung epithelial cells. Estimated in vivo macrophage SPIO nanoparticle doses ranged from 1-100 pg/cell, and induction of inflammatory markers was observed in vitro in macrophages at doses of 8-35 pg/cell. Conclusions: Application of target tissue dosimetry revealed good correspondence between target cell doses triggering inflammatory processes in vitro and in vivo in the alveolar macrophage population, but not in the epithelial cells of the alveolar region. These findings demonstrate the potential for target tissue dosimetry to enable the more quantitative comparison of in vitro and in vivo systems advance their use for hazard assessment and extrapolation to humans. The mildly inflammogentic cellular doses experienced by mice were similar those calculated for humans exposed to the same at the existing permissible exposure limit of 10 mg/m3 iron oxide (as Fe).

Dosimetry↗