Search NASA⌕ Search

SEARCH · Search NASA

Results for “FLUID INJECTION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,189 records · Page 66

Effectiveness of Needleless Vial Adaptors and Blunt Cannulas for Drug Administration in a Microgravity Environment

Fluid Isolation in the medication vial: Air/ fluid isolation maneuvers were used to move the medication to the septum end of vial. This isolation may be achieved in multiple ways based on the experience of the astronaut with fluid management in microgravity. If vial adaptors/blunt cannula or syringe assembly is inserted into the to vial before fluid isolation commences, the stability of this assembly should be considered in an effort to limit the risk of "slinging off" of the vial during isolation. Alternatively, fluid isolation can be performed prior to attaching the syringe/vial adaptor assembly. Terrestrial practices for medication withdrawal from a nonvented vial require injection of an equivalent amount of air as the expected medication volume prior to withdrawing liquid. In microgravity, this action is still valid, however the injection of additional air into the vial creates a multitude of micro bubbles and increases the volume of medication mixed with air that then must be withdrawn to achieve the desired drug volume in syringe. This practice is more likely to be required when using vials >30ml in size and injection volumes >10mL. It is felt that based on the microgravity flight, the practice of air injection is more of a hindrance than help.

Hailey, M.↗

Analysis of Probe Surveys Conducted in the 10-MW TP3 Arc-Jet Facility 15-Inch Nozzle Flow

Computational simulations and analysis of flow characterization tests in a high enthalpy arc-jet facility at NASA Ames Research Center are reported. These tests were conducted in the 10-MW TP3 facility 15-inch conical nozzle, and pitot pressure and heat flux probes are used to survey test flow downstream of the nozzle exit. Two 1.59-cm (0.625 in) diameter hemisphere probes were used: one with a stagnation-point pressure port, the other with a Gardon heat flux gage. Calibration data were also obtained using 10.16-cm iso-q and 20.32-cm flat-faced slug calorimeters. Experimental surveys of arc-jet test flow with pitot pressure and heat flux probes were obtained at eight arc-heater conditions, covering wide ranges in arc current (316–1756 A) and mass flow rate (32–500 g/s, without any cold-gas injection at the arc-heater plenum) and providing assessment of the flow uniformity in the facility. The present analysis comprises computational fluid dynamics simulations of the nonequilibrium flowfield in the facility nozzle and test box, including the models tested. These simulations take into account non-uniform total enthalpy and mass flux profiles at the nozzle inlet as well as the expansion waves emanating from the nozzle exit and their effects on the model flowfields. Comparisons of computations with the experimental measurements are presented, showing reasonably good agreement. The probe survey data and accompanying analysis show that the test flow in the TP3 15-inch nozzle is highly non-uniform at most conditions, and the extent of flow non-uniformity depends on arc current and mass flow rate.

Arc-jets↗

Analysis of Probe Surveys Conducted in the 10-MW TP3 Arc-Jet Facility 15-Inch Nozzle Flow

Computational simulations and analysis of flow characterization tests in a high enthalpy arc-jet facility at NASA Ames Research Center are reported. These tests were conducted in the 10-MW TP3 facility 15-inch conical nozzle, and pitot pressure and heat flux probes are used to survey test flow downstream of the nozzle exit. Two 1.59-cm (0.625 in) diameter hemisphere probes were used: one with a stagnation-point pressure port, the other with a Gardon heat flux gage. Calibration data were also obtained using 20.32-cm flat-faced slug calorimeters. Experimental surveys of arc-jet test flow with pitot pressure and heat flux probes were obtained at eight arc-heater conditions, covering wide ranges in arc current (316–1756 A) and mass flow rate (32–500 g/s, without any cold-gas injection at the arc-heater plenum) and providing assessment of the flow uniformity in the facility. The present analysis comprises computational fluid dynamics simulations of the nonequilibrium flowfield in the facility nozzle and test box, including the models tested. These simulations take into account non-uniform total enthalpy and mass flux profiles at the nozzle inlet as well as the expansion waves emanating from the nozzle exit and their effects on the model flowfields. Comparisons of computations with the experimental measurements are presented, showing reasonably good agreement. The probe survey data and accompanying analysis show that the test flow in the TP3 15-inch nozzle is highly non-uniform at most conditions, and the extent of flow non-uniformity depends on arc current and mass flow rate.

Arc-jets↗

Evaluation of Spray and Combustion Models for Simulating Dilute Combustion in a Direct-Injection Spark-Ignition Engine

Dilute combustion in spark-ignition engines has the potential to improve thermal efficiency by mitigating knock and by reducing throttling and wall heat losses. However, ignition and combustion processes can become unstable for dilute operation due to a lowered laminar flame speed, resulting in excessive cycle-to-cycle variability (CCV) of the combustion process. To compensate for the slower combustion in less reactive mixtures, a modified intake port geometry can be employed to generate a strong tumble flow in the cylinder and elevate turbulence levels around the spark plug, thereby promoting a faster transition to turbulent deflagration. Consequently, optimizing combustion chamber geometry and operating strategy is crucial to maximizing the benefits of using dilute combustion with enhanced in-cylinder turbulence across a wide range of operating conditions. Computational fluid dynamics (CFD) simulations can be utilized for virtual engine optimization tasks, but this would require the models to be truly predictive regarding the impact of changes to the engine design and operational parameters.In this study, multicycle large-eddy simulations (LES) are performed for a direct-injection spark-ignition engine to investigate the model performance in predicting engine combustion characteristics with respect to changes in the intake configuration. A tumble plate that blocks the lower part of the intake port inlet is used to vary the tumble. A set of CFD models that have been recently developed are employed, which takes into account the drag of nonspherical droplets, flash-boiling behavior of liquid sprays, spray-wall interaction, surrogate formulation of a research-grade E10 gasoline, and fast chemical kinetic solvers. Simulation results are compared to experimental engine data in terms of cylinder pressure, apparent heat release rate, mass fraction burned timing, and flame images. It is found that LES employing the state-of-the-art CFD models are capable of properly predicting the spray processes and reproducing the measured mean cylinder pressure for the case with the tumble plate. On the other hand, the LES over-predicts the combustion rate during the early combustion stage and under-estimates the CCV, and these discrepancies become larger when the tumble plate is removed.

computational fluid dynamics simulation↗

Training Graduate and Undergraduate Students in Simulation and Risk Assessment for Carbon Sequestration

Capturing carbon dioxide (CO 2 ) and injecting it into deep underground formations for storage (carbon capture and underground storage, or CCUS) is one way of reducing anthropogenic CO 2 emissions. Gas or aqueous-phase leakage may occur due to transport via faults and fractures, through faulty well bores, or through leaky confining materials. Contaminants of concern include aqueous salts and dissolved solids, gaseous or aqueous-phase organic contaminants, and acidic gas or aqueous-phase fluids that can liberate metals from aquifer minerals. Understanding the mechanisms and parameters that can contribute to leakage of the CO 2 and the ultimate impact on shallow water aquifers that overlie injection formations is an important step in evaluating the efficacy and risks associated with long-term CO 2 storage.

McCray, John↗

High Fidelity Simulations of a Non-Premixed Rotating Detonation Engine

Over the last two decades, detonation based propulsion concepts have received a great deal of attention as a means to achieve significant improvement in the performance of air-breathing and rocket engines. Detonative combustion mode is particularly interesting due to the resulting pressure gain from reactants to products, faster heat release, decreased entropy generation, more available work and higher thrust compared to conventional deflagrative combustion. Rotating detonation engine (RDE) is one such class of novel combustor concepts. Realistic RDE configurations utilize separate fuel and air injection schemes, hence are not perfectly premixed. Moreover, the performance of RDEs is governed by a large number of design parameters and operating conditions. In this context, computational fluid dynamics (CFD) has the potential to enhance the understanding of RDE combustion and aid future development/optimization of this technology. In the present work, a CFD model was developed to simulate a representative non-premixed RDE combustor at the US Air Force Research Laboratory (AFRL). To resolve the reacting flow in the combustor, a finite-rate chemistry model was employed. In addition, adaptive mesh refinement (AMR) was incorporated to achieve a good trade-off between model accuracy and computational expense. Unsteady Reynolds-Averaged Navier-Stokes (RANS) simulations were performed for the full combustor (including the separate fuel and air injection ports) geometry, with hydrogen as fuel and air as the oxidizer. A 10-species detailed kinetic mechanism was employed to describe the H2-Air combustion chemistry. Two different operating conditions were simulated, corresponding to the same global equivalence ratio of unity but different fuel and air mass flow rates. For both conditions, the capability of the model to capture the essential detonation wave dynamics was assessed. A validation study was performed against a wide variety of experimental data available on detonation wave frequency/height, reactant fill height, oblique shock angle, axial pressure distribution in the channel, and fuel/air plenum pressure. The CFD model predicted the sensitivity of all these wave characteristics to the operating conditions with good accuracy, both qualitatively and quantitatively. The present CFD model offers a potential capability to perform rapid design space exploration and/or performance optimization studies for realistic full-scale RDE configurations.

Cocks, Peter A.↗

A Numerical Study of Two-Phase Flow and Interfacial Mass Transfer in a Wetted Wall Column for Counter-Current Gas Absorption

We present a numerical study to investigate the effects of surface waves of falling films on the mass transfer from flowing gas phase into the liquid film. The model employs the volume of fluid method to explicitly track the gas-liquid phase interface and a one-fluid formulation to model the multiphase flow coupled with mass transfer between the two phases. The surface waves are generated by the time-varying injection rate of the falling film. The effects of surface wave frequencies and amplitudes on the overall mass transfer also are investigated for a counter-current gas-liquid flow of oxygen and water. Because of the solubility difference in the two phases, the model can capture the concentration discontinuity across the liquid-gas interface. Good agreement is obtained between the numerical results and experimental data reported in the literature. By systematically varying the frequencies and amplitudes of flow rate for the falling film, the surface waves generated on the film surface enhance mass transfer in general. Here, the model prediction shows a proportional increase in mass transfer for small frequencies of surface waves, but saturation at higher frequencies.

42 ENGINEERING↗

Applying colloidal silica suspensions injection and sequential gelation to block vertical water flow in well annulus: laboratory testing on rheology, gelation, and injection

We evaluated the application of silica suspension injection and sequential gelation to block vertical water flow in the annuli of long-screened wells. First, we studied the viscosity, rheological behavior, and gelation performance of colloidal silica suspensions in batch tests. Then, we tested the injection of silica suspensions and the water flow blocking efficiency of the later formed silica gel in column and bench-scale sandbox experiments. Micron-sized fumed powder silica suspensions and nanosized silica suspensions recovered from geothermal fluids were tested in this work. Fumed silica suspensions showed shear thinning, while nanosized silica suspensions exhibited Newtonian flow behavior. During the gelation process, the nanosized silica suspension changed from a Newtonian fluid to a shear thinning fluid while increasing its overall viscosity. At comparable concentrations, the nanosized silica suspensions have much lower viscosity than that of the fumed silica suspensions. Increases in the Na + concentration and silica particle concentration in these suspensions shortened the gelation time. Silica suspension gelation in sand columns completely blocked the water flow and sustained the injection pressure up to 50 psig (344.7 kPa). A silica suspension was successfully injected into the target zone in the annulus of a bench-scale sandbox mimicking long-screened wells in the field. The silica gel formed in the annulus effectively blocked chemical transport through the gelled zone. Our research reveals that a process using silica suspension injection and sequential gelation technology is promising for blocking the vertical water flow and chemical transport through the filter pack in targeted zones within the annulus of long-screened well systems.

54 ENVIRONMENTAL SCIENCES↗

Application of gas-liquid fluid dynamics techniques to the modeling of sprays

The purpose of this paper is to provide an overview of modern computational techniques for gas-liquid systems as they are found in liquid fuel atomization applications. Fuel atomization – the generation of ligaments and droplets from the bulk of liquid injection – offers several modeling challenges: a localized surface tension force, depending on the accurate evaluation of interface curvature; drastic topology changes, which complicate interface advection and introduce local length scales; and separation of phases that have substantially different physical properties. The techniques presented in this review specifically target the gas-liquid interface and couple its evolution in time with the equations of multiphase fluid dynamics. Recent algorithmic advances in this area are discussed first, including new methods that improve conservation properties and deal with very large density ratios and compressibility effects. This part is followed by a discussion on the issue of convergence in simulations with topology changes (i.e., surface pinch-off) and on the viewpoint offered by atomistic and statistical modeling. State-of the-art simulations for various types of fuel injectors are presented next, with particular attention to numerical convergence and to the inclusion of realistic inlet boundary conditions. The review is concluded by the discussion of some of the challenges that still remains in this field.

42 ENGINEERING↗

APPARATUS AND METHOD FOR TREATING POLLUTANTS IN A GAS USING HYDROGEN PEROXIDE AND UV LIGHT

An apparatus for treating pollutants in a gas may include a source of hydrogen peroxide, and a treatment injector for creating and injecting dissociated hydrogen peroxide into the flow of gas. The treatment injector may further include an injector housing having an inlet, an outlet, and a hollow interior extending there between. The inlet may be connected in fluid communication with the source of hydrogen peroxide so that hydrogen peroxide flows through the hollow interior and toward the outlet. At least one ultraviolet (UV) lamp may be positioned within the hollow interior of the injector housing. The at least one UV lamp may dissociate the hydrogen peroxide flowing through the tube. The dissociated hydrogen peroxide may be injected into the flow of gas from the outlet for treating pollutants, such as nitrogen oxides.

Cooper, Charles David↗

Response surface data for sensitivity study of industrial spray injected fluidized bed reactor

An industrial fluidized bed reactor was designed to convert an aqueous solid laden stream into a consistent granular product. CFD simulations were run using the MFiX two-fluid model for this fluidizing bed operating at 650 °C. A set of simulations were run over a Latin-hypercube sample of five model parameters – bed particle size, bed particle density, coal particle size, spray feed flow rate, and fluidizing gas flow rate. Data from the simulations were collected on three quantities of interest – bed differential temperature, low solids velocity, and bed voidage. The data presented here is the full span of response surfaces generated using the process Gaussian response surface model in the Dakota code, as well as the table of data for coefficients of the fitted model. The fits to the five-dimensional Gaussian Process models were 0.7797, 0.8664, and 0.9440 for the temperature, velocity, and solids packing, respectively.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Hybrid Propulsion Based on Fluid-Controlled Solid Gas Generators

The use of fuel-rich solid (gas generator-type) propellants for hybrid propulsion affords some design and utilization efficiency advantages. Both forward and aft liquid injection control concepts are evaluated form the operational standpoints of ballistics, throttling, Stability and extinguishment.

Propulsion↗

Shock injector for low-laser energy electron injection in a laser plasma accelerator

This disclosure provides systems, methods, and apparatus related to laser plasma accelerators. In one aspect a block of material defines a gas inlet, a chamber in fluid communication with the gas inlet, a throat in fluid communication with the chamber, a channel in fluid communication with the throat, and a gas outlet in fluid communication with the channel. The throat is configured to generate a supersonic flow of a gas when the gas flows through the throat. The channel includes a ramp that is positioned proximate the gas outlet, with the ramp being inclined at an angle with respect to a direction of a flow of the gas proximate a surface of the channel prior to the ramp at the gas outlet.

Mao, Hann -Shin↗

Liquid Microjunction Surface Sampling Probe Fluid Dynamics: Computational and Experimental Analysis of Coaxial Intercapillary Positioning Effects on Sample Manipulation

A coaxial geometry liquid microjunction surface sampling probe (LMJ-SSP) enables direct extraction of analytes from surfaces for subsequent analysis by techniques like mass spectrometry. Solution dynamics at the probe-to-sample surface interface in the LMJ-SSP has been suspected to influence sampling efficiency and dispersion but has not been rigorously investigated. The effect on flow dynamics and analyte transport to the mass spectrometer caused by coaxial retraction of the inner and outer capillaries from each other and the surface during sampling with a LMJ-SSP was investigated using computational fluid dynamics and experimentation. A transparent LMJ-SSP was constructed to provide the means for visual observation of the dynamics of the surface sampling process. Visual observation, computational fluid dynamics (CFD) analysis, and experimental results revealed that inner capillary axial retraction from the flush position relative to the outer capillary transitioned the probe from a continuous sampling and injection mode through an intermediate regime to sample plug formationmode caused by eddy currents at the sampling end of the probe. The potential for analytical implementation of these newly discovered probe operational modes is discussed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

CO 2 -induced chemo-mechanical alteration in reservoir rocks assessed via batch reaction experiments and scratch testing

Here, the injection of carbon dioxide (CO 2 ) into geological formations results in a chemical re-equilibration between the mineral assemblage and the pore fluid, with ensuing mineral dissolution and re-precipitation. Hence, target rock formations may exhibit changes of mechanical and petrophysical properties due to CO 2 exposure. We conducted batch reaction experiments with Entrada Sandstone and Summerville Siltstone exposed to de-ionized water and synthetic brine under reservoir pressure (9–10 MPa) and temperature (80°C) for up to four weeks. Samples originate from the Crystal Geyser field site, where a naturally occurring CO 2 seepage alters portions of these geologic formations. We conducted micro-scratch tests on rock samples without alteration, altered under laboratory conditions, and naturally altered over geologic time. Scratch toughness and hardness decrease as a function of exposure time and water salinity up to 52% in the case of Entrada and 87% in the case of Summerville after CO 2 -induced alteration in the laboratory. Imaging of altered cores with SEM-EDS and X-ray microCT methods show dissolution of carbonate and silica cements and matrix accompanied by minor dissolution of Fe-oxides, clays, and other silicates. Parallel experiments using powdered samples confirm that dissolution of carbonate and silica are the primary reactions. The batch reaction experiments in the autoclave utilize a high fluid to rock volume ratio and represent an end member of possible alteration associated with CO 2 storage systems. These types of tests serve as a pre-screening tool to identify the susceptibility of rock facies to CO 2 -related chemical-mechanical alteration during long-term CO 2 storage.

54 ENVIRONMENTAL SCIENCES↗

Molecular dynamics simulations of field emission from a planar nanodiode

High resolution molecular dynamics simulations with full Coulomb interactions of electrons are used to investigate field emission in planar nanodiodes. The effects of space-charge and emitter radius are examined and compared to previous results concerning transition from Fowler-Nordheim to Child-Langmuir current [Y. Y. Lau, Y. Liu, and R. K. Parker, Phys. Plasmas 1, 2082 (1994) and Y. Feng and J. P. Verboncoeur, Phys. Plasmas 13, 073105 (2006)]. The Fowler-Nordheim law is used to determine the current density injected into the system and the Metropolis-Hastings algorithm to find a favourable point of emission on the emitter surface. A simple fluid like model is also developed and its results are in qualitative agreement with the simulations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Characterization of seminal plasma proteomic alterations associated with the IVF and rescue‐ICSI pregnancy in assisted reproduction

Abstract Background Seminal plasma is a promising diagnostic fluid for male infertility. In assisted reproduction, the seminal plasma‐based characteristics of normozoospermic men achieving successful clinical pregnancy through rescue intracytoplasmic sperm injection after in vitro fertilization failure remain unclear. Objective To identify potential seminal plasma proteins to contribute to a new understanding of unexplained male factor infertility. Materials and Methods An approach with isobaric tags for relative and absolute quantification labeling coupled with liquid chromatography matrix‐assisted laser desorption ionization mass spectrometry was applied to investigate differentially expressed proteins in the seminal plasma of a rescue intracytoplasmic sperm injection pregnancy group versus an in vitro fertilization pregnancy group of normozoospermic men. Result(s) The present work revealed seventy‐three differentially expressed seminal plasma proteins between the in vitro fertilization and rescue intracytoplasmic sperm injection groups. Forty‐five proteins were upregulated, and 28 proteins were downregulated in the rescue intracytoplasmic sperm injection group compared with the in vitro fertilization group. Bioinformatics analyses showed that these altered proteins were involved in various functions, including the kallikrein‐related proteolytic cascade, immune response, and heparin binding. Furthermore, the validity of the proteomic results was verified by Western blot analysis of the proteins (lactoferrin [LTF], fibronectin [FN1], creatine kinase B type [CKB], kallikrein‐2 [KLK2], aminopeptidase N [ANPEP], extracellular matrix protein 1 [ECM1], glycodelin [PAEP], alpha‐1‐antitrypsin [SERPINA1], and semenogelin‐1 [SEMG1]) and immunofluorescence. Moreover, 16% of the seminal plasma proteins identified in the present work have not been reported in previous studies. Discussion This panel of altered seminal plasma proteins associated with unexplained male factor infertility might have clinical relevance and may be useful in the diagnosis and prognosis of idiopathic infertility in in vitro fertilization. Conclusions Our work not only provides a new complementary high‐confidence dataset of seminal plasma proteins but also shines new light onto the molecular characteristics of seminal plasma from normozoospermic men with different assisted reproductive outcomes.

Liu, X.↗

Recent Developments in Hydrogeologic Applications for Strain Tensor Analyses

Changes in fluid pressure deform porous media and this effect occurs in a variety of hydrogeologic processes, from the change in storage during pumping or injection to fluctuations in water levels caused by barometric pressure. We have developed instruments for measuring small strains in porous media, and we have used the resulting strain data to evaluate well testing, hydraulic fracturing, manual loading at the ground surface, and ambient hydrologic processes, like rainfall and evaporation. A particularly important application is the use of strain tensor data measured at shallow depths to analyze well tests or hydraulic fractures conducted at much greater depths. An early demonstration of this technique was conducted at the North Avant Field north of Tulsa, Oklahoma, where Pennsylvanian sandstone creates a confined aquifer and oil reservoir at a depth of 530m. We have showed that the strains caused by injecting into the aquifer could be measured at a depth of 30m and used to evaluate the properties of the aquifer. We recently expanded the array of strainmeters at the North Avant Field by deploying three more instruments at shallow depth (30m) along with a deep instrument at 520m depth in the winter, 2021. The deep instrument is deployed in shale caprock slightly above the aquifer. To our knowledge, the deep strainmeter at the North Avant Field is the deepest strainmeter ever deployed and this required refining methods originally developed for shallow deployments. The instrument was lowered to depth on oil field tubing and cemented in place using techniques and materials developed for use in oil wells. Optical fiber used to communicate with the instrument was cemented in the annulus on the outside of tubing. This is significant because the techniques we used could readily be extended to greater depth, suggesting that strainmeters can be deployed over a wide range of depths for monitoring critical subsurface processes. For example, it suggests that strainmeters could be deployed through the caprock to monitor for leaks from underlying CO2 storage reservoirs. The strainmeter array at the North Avant Field has been used to characterize deformation during a series of injection tests in the spring and summer, 2021. All the new strainmeters respond to pumping, and the strainmeters we installed earlier also responded. To our knowledge, this is the first application of well testing in a deep aquifer that was monitored by an array of strainmeters—our earlier work used strainmeters at a single location. We are currently analyzing the strain data using an analytical solution, a proxy-based Bayesian inversion algorithm, and other methods. Strainmeter data has also been used to characterize periodic pumping tests by us and Riley Blais. A periodically varying pumping rate causes both hydraulic head and strain signals that vary with the same period as the pumping. The peaks and troughs of the head in monitoring wells lag behind the peaks and troughs of the head in the pumping well, and this lag time increases with distance from the pumping well. The lag time of the pressure and the distance to the monitoring well can be used in a simple analysis to estimate the hydraulic diffusivity of the aquifer. The lag time determined from strain data can be used to estimate aquifer properties using the same analysis that works for the pressure only for strain data measured at particular locations. That is because the strain field in a confining unit advances upward, laterally and then downward even though the pressure in the underlying aquifer only advances laterally, according to our recent simulations. We have field data showing that a small periodic signal superimposed on an injection rate at the North Avant Field will create a periodic strain signal at shallow strainmeters. The field data and the recent simulations suggest that including a periodic component to injection or pumping and then monitoring the resulting strain signal could be a way to monitor the subsurface.

Murdoch, Larry↗