Search NASA⌕ Search

SEARCH · Search NASA

Results for “IRRADIATION DEVICES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,189 records · Page 66

Bright and stable light-emitting diodes made with perovskite nanocrystals stabilized in metal–organic frameworks

Perovskite nanocrystals are exceptional candidates for light-emitting diodes (LEDs). However, they are unstable in the solid film and tend to degrade back to the bulk phase, which undermines their potential for LEDs. Here we demonstrate that perovskite nanocrystals stabilized in metal–organic framework (MOF) thin films make bright and stable LEDs. The perovskite nanocrystals in MOF thin films can maintain the photoluminescence and electroluminescence against continuous ultraviolet irradiation, heat and electrical stress. As revealed by optical and X-ray spectroscopy, the strong emission originates from localized carrier recombination. Bright LEDs made from perovskite-MOF nanocrystals are demonstrated with a maximum external quantum efficiency of over 15% and a high brightness of over 10 5 cd m -2 after the device reaches stabilization. During LED operation, the nanocrystals can be well preserved, free of ion migration or crystal merging through protection by the MOF matrix, leading to a stable performance over 50 hours.

36 MATERIALS SCIENCE↗

Three-dimensional micronanofabrication via two-photon-excited photoisomerization

In this letter, laser micronanofabrication via two-photon absorption initiated isomerization was proposed and explored. Experimentally a cis-form rich poly[2,5-dihexyloxy-1,4-phenylene] vinylene)-alt-(2,5-diphenyl-1,4-phenylene vinylene)] (DPO-PPV) was used as the precursory material, which underwent pinpoint molecular conformational change upon the near-infrared femtosecond laser irradiation. Due to pronouncedly reduced solubility of trans-configuration molecules, the precipitate at the tiny volumes was implemented as voxels to construct two- and three-dimensional micronanostructures. This mechanism may provide an alternative enabling tool other than two-photon absorption initiated polymerization of resins for designable micronanofabrication of photonic or optoelectronic devices including organic electroluminescent devices, particularly those based on PPV and its derivatives.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Improved passivation of the ZnO/Si interface by pulsed laser deposition

Zinc oxide thin-films were grown on crystalline silicon employing magnetron sputtering and pulsed laser deposition. Bulk and interface properties were investigated using scanning electron microscopy, Raman backscattering, photoluminescence, and infrared spectroscopic ellipsometry. Sputter deposited ZnO samples reveal a large degree of disorder and an interface defect density of Almost-Equal-To 10{sup 12} cm{sup -2}. A significant improvement of the structural quality is observed in samples grown by pulsed laser deposition. The bulk defect density is further reduced, when introducing monatomic oxygen during deposition. Simultaneously, the defect density at the ZnO/Si interface decreases by about a factor of five. Implications for devices containing ZnO/Si interfaces are discussed.

36 MATERIALS SCIENCE↗

Time delay and integration array (TDI) using charge transfer device technology. Phase 2, volume 1: Technical

The 20x9 TDI array was developed to meet the LANDSAT Thematic Mapper Requirements. This array is based upon a self-aligned, transparent gate, buried channel process. The process features: (1) buried channel, four phase, overlapping gate CCD's for high transfer efficiency without fat zero; (2) self-aligned transistors to minimize clock feedthrough and parasitic capacitance; and (3) transparent tin oxide electrode for high quantum efficiency with front surface irradiation. The requirements placed on the array and the performance achieved are summarized. This data is the result of flat field measurements only, no imaging or dynamic target measurements were made during this program. Measurements were performed with two different test stands. The bench test equipment fabricated for this program operated at the 8 micro sec line time and employed simple sampling of the gated MOSFET output video signal. The second stand employed Correlated Doubled Sampling (CDS) and operated at 79.2 micro sec line time.

Source record↗

Magnetic properties of intercalated quasi-2D Fe 3-x GeTe 2 van der Waals magnet

Among several well-known transition metal-based compounds, cleavable van der Waals (vdW) Fe 3-x GeTe 2 (FGT) magnet is a strong candidate for use in two-dimensional (2D) magnetic devices due to its strong perpendicular magnetic anisotropy, sizeable Curie temperature (T C ~154 K), and versatile magnetic character that is retained in the low-dimensional limit. While the T C remains far too low for practical applications, there has been a successful push toward improving it via external driving forces such as pressure, irradiation, and doping. Here we present experimental evidence of a room temperature (RT) ferromagnetic phase induced by the electrochemical intercalation of common tetrabutylammonium cations (TBA+) into quasi-2D FGT. We obtained Curie temperatures as high as 350 K with chemical and physical stability of the intercalated compound. The temperature-dependent Raman measurements, in combination with vdW-corrected ab initio calculations, suggest that charge transfer (electron doping) upon intercalation could lead to the observation of RT ferromagnetism. This work demonstrates that molecular intercalation is a viable route in realizing high-temperature vdW magnets in an inexpensive and reliable manner and has the potential to be extended to bilayer and few-layer vdW magnets.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Raman spectroscopy and electrical properties of InAs nanowires with local oxidation enabled by substrate micro-trenches and laser irradiation

The thermal gradients along indium arsenide nanowires were engineered by a combination of fabricated micro-trenches in the supporting substrate and focused laser irradiation. This allowed local spatial control of thermally activated oxidation reactions of the nanowire on the scale of the diffraction limit. The locality of the oxidation was detected by micro-Raman mapping, and the results were found to be consistent with numerical simulations of the temperature profile. Applying the technique to nanowires in electrical devices the locally oxidized nanowires remained conducting with a lower conductance as expected for an effectively thinner conducting core.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Investigating the limits of PET/CT imaging at very low true count rates and high random fractions in ion-beam therapy monitoring

Purpose: External beam radiotherapy with protons and heavier ions enables a tighter conformation of the applied dose to arbitrarily shaped tumor volumes with respect to photons, but is more sensitive to uncertainties in the radiotherapeutic treatment chain. Consequently, an independent verification of the applied treatment is highly desirable. For this purpose, the irradiation-induced β{sup +}-emitter distribution within the patient is detected shortly after irradiation by a commercial full-ring positron emission tomography/x-ray computed tomography (PET/CT) scanner installed next to the treatment rooms at the Heidelberg Ion-Beam Therapy Center (HIT). A major challenge to this approach is posed by the small number of detected coincidences. This contribution aims at characterizing the performance of the used PET/CT device and identifying the best-performing reconstruction algorithm under the particular statistical conditions of PET-based treatment monitoring. Moreover, this study addresses the impact of radiation background from the intrinsically radioactive lutetium-oxyorthosilicate (LSO)-based detectors at low counts. Methods: The authors have acquired 30 subsequent PET scans of a cylindrical phantom emulating a patientlike activity pattern and spanning the entire patient counting regime in terms of true coincidences and random fractions (RFs). Accuracy and precision of activity quantification, image noise, and geometrical fidelity of the scanner have been investigated for various reconstruction algorithms and settings in order to identify a practical, well-suited reconstruction scheme for PET-based treatment verification. Truncated listmode data have been utilized for separating the effects of small true count numbers and high RFs on the reconstructed images. A corresponding simulation study enabled extending the results to an even wider range of counting statistics and to additionally investigate the impact of scatter coincidences. Eventually, the recommended reconstruction scheme has been applied to exemplary postirradiation patient data-sets. Results: Among the investigated reconstruction options, the overall best results in terms of image noise, activity quantification, and accurate geometrical recovery were achieved using the ordered subset expectation maximization reconstruction algorithm with time-of-flight (TOF) and point-spread function (PSF) information. For this algorithm, reasonably accurate (better than 5%) and precise (uncertainty of the mean activity below 10%) imaging can be provided down to 80 000 true coincidences at 96% RF. Image noise and geometrical fidelity are generally improved for fewer iterations. The main limitation for PET-based treatment monitoring has been identified in the small number of true coincidences, rather than the high intrinsic random background. Application of the optimized reconstruction scheme to patient data-sets results in a 25% − 50% reduced image noise at a comparable activity quantification accuracy and an improved geometrical performance with respect to the formerly used reconstruction scheme at HIT, adopted from nuclear medicine applications. Conclusions: Under the poor statistical conditions in PET-based treatment monitoring, improved results can be achieved by considering PSF and TOF information during image reconstruction and by applying less iterations than in conventional nuclear medicine imaging. Geometrical fidelity and image noise are mainly limited by the low number of true coincidences, not the high LSO-related random background. The retrieved results might also impact other emerging PET applications at low counting statistics.

60 APPLIED LIFE SCIENCES↗

Deep levels and radiation effects in p-InP

A survey was conducted on past studies of hole traps in InP. An experiment was designed to evaluate hole traps in Zn-doped InP after fabrication, after electron irradiation and after annealing using deep level transient spectroscopy. Data similar to that of Yamaguchi was seen with observation of both radiation-induced hole and electron traps at E sub A=0.45 eV and 0.03 eV, respectively. Both traps are altered by annealing. It is also shown that trap parameters for surface-barrier devices are influenced by many factors such as bias voltage, which probes traps at different depths below the surface. These devices require great care in data evaluation.

Anderson, W. A.↗

SU-D-BRE-05: Feasibility and Limitations of Laser-Driven Proton Therapy: A Treatment Planning Study

Purpose: Laser-acceleration of particles may offer a cost- and spaceefficient alternative for future radiation therapy with particles. Laser-driven particle beams are pulsed with very short bunch times, and a high number of particles is delivered within one laser shot which cannot be portioned or modulated during irradiation. The goal of this study was to examine whether good treatment plans can be produced for laser-driven proton beams and to investigate the feasibility of a laser-driven treatment unit. Methods: An exponentially decaying proton spectrum was tracked through a gantry and energy selection beam line design to produce multiple proton spectra with different energy widths centered on various nominal energies. These spectra were fed into a treatment planning system to calculate spot scanning proton plans using different lateral widths of the beam and different numbers of protons contained in the initial spectrum. The clinical feasibility of the resulting plans was analyzed in terms of dosimetric quality and the required number of laser shots as an estimation of the overall treatment time. Results: We were able to produce treatment plans with plan qualities of clinical relevance for a maximum initial proton number per laser shot of 6*10{sup 8}. However, the associated minimum number of laser shots was in the order of 10{sup 4}, indicating a long delivery time in the order of at least 15 minutes, when assuming an optimistic repetition rate of the laser system of 10 Hz. Conclusion: With the simulated beam line and the assumed shape of the proton spectrum it was impossible to produce clinically acceptable treatment plans that can be delivered in a reasonable time. The situation can be improved by a method or a device in the beam line which can modulate the number of protons from shot to shot. Supported by DFG Cluster of Excellence: Munich-Centre for Advanced Photonics.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Enhanced tunable magnetoresistance properties over a wide temperature range in epitaxial (La{sub 0.7}Sr{sub 0.3}MnO{sub 3}){sub 1−x}:(CeO{sub 2}){sub x} nanocomposites

Vertically aligned nanocomposite (VAN) (La{sub 0.7}Sr{sub 0.3}MnO{sub 3}){sub 1−x}:(CeO{sub 2}){sub x} (LSMO:CeO{sub 2}) thin films have been grown on SrTiO{sub 3} (001) substrates by pulsed laser deposition. Tunable magnetoresistance properties as well as microstructures are demonstrated in these VAN films by modulating the film composition (x = 0, 0.3, 0.4, 0.45, 0.5, and 0.55). The sample of x = 0.3 shows a large low-field magnetoresistance (LFMR) in a high temperature range, i.e., over 10% at the range of 280 K to 320 K under 1 T and with a peak value of ∼13.5% at 310 K. In addition, a vast enhancement of LFMR in a low temperature range of 20–150 K with peak of ≈34.3% at 45 K for 1 T could be achieved with x = 0.5. The enhanced LFMR properties can be attributed to both the phase boundary induced spin fluctuation and the magnetic tunneling effect through vertical ferromagnetic/insulator/ferromagnetic structures. The observed enhanced LFMR performance, especially at high temperatures, as well as its simple growth method, offers a great potential for LSMO:CeO{sub 2}nanocomposites to be used in spintronic devices in a large temperature range.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Dosimetric optimization of a conical breast brachytherapy applicator for improved skin dose sparing

Purpose: Both the AccuBoost D-shaped and round applicators have been dosimetrically characterized and clinically used to treat patients with breast cancer. While the round applicators provide conformal dose coverage, under certain clinical circumstances the breast skin dose may be higher than preferred. The purpose of this study was to modify the round applicators to minimize skin dose while not substantially affecting dose uniformity within the target volume and reducing the treatment time. Methods: In order to irradiate the intended volume while sparing critical structures such as the skin, the current round applicator design has been augmented through the addition of an internal truncated cone (i.e., frustum) shield. Monte Carlo methods and clinical constraints were used to design the optimal cone applicator. With the cone applicator now defined as the entire assembly including the surrounding tungsten-alloy shell holding the HDR {sup 192}Ir source catheter, the applicator height was reduced to diminish the treatment time while minimizing skin dose. Monte Carlo simulation results were validated using both radiochromic film and ionization chamber measurements based on established techniques. Results: The optimal cone applicators diminished the maximum skin dose by 15%-32% (based on the applicator diameter and breast separation) with the tumor dose reduced by less than 3% for a constant exposure time. Furthermore, reduction in applicator height diminished the treatment time by up to 30%. Radiochromic film and ionization chamber dosimetric results in phantom agreed with Monte Carlo simulation results typically within 3%. Larger differences were outside the treatment volume in low dose regions or associated with differences between the measurement and Monte Carlo simulation environments. Conclusions: A new radiotherapy treatment device was developed and dosimetrically characterized. This set of applicators significantly reduces the skin dose and treatment time while retaining uniform target dose.

60 APPLIED LIFE SCIENCES↗

Self-healing effects in a semi-ordered liquid for stable electronic conversion of high-energy radiation

Radiation damage in solid-state semiconductors has, until now, placed strict limitations on the acceptable decay energies of radioisotopes in radiovoltaic cells. Relegation to low-energy beta-emitting isotopes has minimized the power output from these devices and limited the technology’s ability to deliver greater energy densities and longer lifetimes than conventional batteries. We demonstrate the self-healing abilities of a liquid-phase semiconducting alloy which can withstand high-energy alpha radiation. Neutron difraction of liquid selenium-sulfur shows the liquid phase repairing damage sustained in the irradiation of the solid phase. This self-healing behavior results in long-lived power output in a liquid selenium-sulfur alphavoltaic cell. To the best of our knowledge, this marks the only successful demonstration of resistance to high-energy radiation (>500keV) in a semiconducting material. This new robustness can potentially allow increases to the available energy density in radiovoltaic cells near 1000 times the current state of the art.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Ultrafast gated imaging of laser produced plasmas using the optical Kerr effect

Optical imaging is a versatile diagnostic for investigations of plasmas generated under intense laser irradiation. Electro-optic gating techniques operating on the >100 ps timescale are commonly used to reduce the amount of light detected from self-emission of hot plasma or improve the temporal resolution of the detector. The use of an optical Kerr gate enables a superior dynamic range and temporal resolution compared to electronically gated devices. The application of this method for enhanced imaging of laser produced plasmas with gate time approx100 fs is demonstrated, and the possibility to produce a sub-10 fs, high dynamic range 'all optical' streak camera is discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

TU-C-BRE-04: 3D Gel Dosimetry Using ViewRay On-Board MR Scanner: A Feasibility Study

Purpose: MR based 3D gel has been proposed for radiation therapy dosimetry. However, access to MR scanner has been one of the limiting factors for its wide acceptance. Recent commercialization of an on-board MR-IGRT device (ViewRay) may render the availability issue less of a concern. This work reports our attempts to simulate MR based dose measurement accuracy on ViewRay using three different gels. Methods: A spherical BANG gel dosimeter was purchased from MGS Research. Cylindrical MAGIC gel and Fricke gel were fabricated in-house according to published recipes. After irradiation, BANG and MAGIC were imaged using a dual-echo spin echo sequence for T2 measurement on a Philips 1.5T MR scanner, while Fricke gel was imaged using multiple spin echo sequences. Difference between MR measured and TPS calculated dose was defined as noise. The noise power spectrum was calculated and then simulated for the 0.35 T magnetic field associated with ViewRay. The estimated noise was then added to TG-119 test cases to simulate measured dose distributions. Simulated measurements were evaluated against TPS calculated doses using gamma analysis. Results: Given same gel, sequence and coil setup, with a FOV of 180×90×90 mm3, resolution of 3×3×3 mm3, and scanning time of 30 minutes, the simulated measured dose distribution using BANG would have a gamma passing rate greater than 90% (3%/3mm and absolute). With a FOV 180×90×90 mm3, resolution of 4×4×5 mm3, and scanning time of 45 minutes, the simulated measuremened dose distribution would have a gamma passing rate greater than 97%. MAGIC exhibited similar performance while Fricke gel was inferior due to much higher noise. Conclusions: The simulation results demonstrated that it may be feasible to use MAGIC and BANG gels for 3D dose verification using ViewRay low-field on-board MRI scanner.

60 APPLIED LIFE SCIENCES↗

Low-noise, radiation tolerant SiCpms

Over the last 10 years, our R&D effort has resulted in a steady progress on improving Geiger detector array technology performance, verifying their reliability and developing three cell layout libraries containing more than 2200 primitive cells for Si and SiC Geiger based single-photon detectors and silicon ROIC array fabrication. Awards from DOE, NASA and DOD, as wells as commercial R&D orders supported much progress, relevant to this program. The expertise gained and the technologies developed or qualified during these programs provided the design database and expertise to carry out the development of this new SiC photomultiplier (SiCpm) technology, successful fabrication of SiCpm detectors, and evaluation of their radiation hardness. After irradiation with protons and neutrons at 1015cm-2 and 1014cm-2 respectively, SiCpms proved radiation hardness, exceeding the expected radiation tolerance The defects induced by irradiation were mainly point defects. A new improved DLTS method (fDLTS – full wave DLTS) hardware and data processing software specific to investigating radiation damage in SiC was developed. Further work is needed to better characterize and control defects induced by charged particles. We recommend further funding of radiation hardened technology development and validation; qualification of device-specific characterization methods like f-DLTS, development of more methods to evaluate defects in SiC, more active involvement of the national labs in evaluating the SiCpm devices, and DOE support of technology transfer to a qualified foundry.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

1985 Annual Conference on Nuclear and Space Radiation Effects, 22nd, Monterey, CA, July 22-24, 1985, Proceedings

Basic mechanisms of radiation effects in structures and materials are discussed, taking into account the time dependence of interface state production, process dependent build-up of interface states in irradiated N-channel MOSFETs, bias annealing of radiation and bias induced positive charges in n- and p-type MOS capacitors, hole removal in thin-gate MOSFETs by tunneling, and activation energies of oxide charge recovery in SOS or SOI structures after an ionizing pulse. Other topics investigated are related to radiation effects in devices, radiation effects in integrated circuits, spacecraft charging and space radiation effects, single-event phenomena, hardness assurance and radiation sources, SGEMP/IEMP phenomena, EMP phenomena, and dosimetry and energy-dependent effects. Attention is given to a model of the plasma wake generated by a large object, gate charge collection and induced drain current in GaAs FETs, simulation of charge collection in a multilayer device, and time dependent dose enhancement effects on integrated circuit transient response mechanisms.

Jones, C. W.↗

Proton-induced radiation damage in germanium detectors

High-purity germanium (HPGe) detectors will be used in future space missions for gamma-ray measurements and will be subject to interactions with energetic particles. To simulate this process, several large-volume n-type HPGe detectors were incrementally exposed to a particle fluence of up to 10 to the 8th protons/sq cm (proton energy: 1.5 GeV) at different operating temperatures (90 to 120 K) to induce radiation damage. Basic scientific and engineering data on detector performance were collected. During the incremental irradiation, the peak shape produced by the detectors showed a significant change from a Gaussian shape to a broad complex structure. After the irradiation, all detectors were thoroughly characterized by measuring many parameters. To remove the accumulated radiation damage, the detectors were stepwise-annealed at temperatures below 110 C, while kept in their specially designed cryostats. This study shows that n-type HPGe detectors can be used in charged-particle environments as high-energy resolution devices until a certain level of radiation damage is accumulated and that the damage can be removed at moderate annealing temperatures and the detector returned to operating condition.

Brueckner, J.↗

PE99155 Point-Of-Load Buck Regulator Total Ionizing Dose Test Report

Teledyne’s PE99155 point-of-load buck regulator was tested to evaluate an applicationspecific question about the start-up behavior of the device. This test determined if accumulated total ionizing dose (TID) affected any start-up voltage transient characteristics. Testing was based on pass/fail criterial for the magnitude of the output voltage to ensure the safety of downstream electronics. Two sets of radiation tests were performed. The first group of PE99155s used a high dose rate (HDR) irradiation to 25 krad(Si). A second group of PE99155s used high dose rate irradiation to 30 krad(Si).

TID↗