Search NASA⌕ Search

SEARCH · Search NASA

Results for “MAGNET SYSTEM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,189 records · Page 66

Recovering the Waste Energy from the Electron-Ion Collider Cooling Water Systems

While only a fraction of the electricity required for the EIC goes into the collision itself, most of the energy ultimately ends up being rejected to the environment via the infrastructure cooling systems. The energy utilized by the RF amplifiers, power supplies, magnets, vacuum systems, and cryogenics systems is rejected to the cooling towers that ultimately dissipate the energy to the atmosphere. Current estimates indicate approximately 50 MW of heat is dissipated at a low temperature by the cooling towers. This technical note is prepared to conceptually demonstrate that feasible options exist to recover the low temperature energy from the EIC cooling water systems.

43 PARTICLE ACCELERATORS↗

Effects of window size and shape on accuracy of subpixel centroid estimation of target images

A new algorithm is presented for increasing the accuracy of subpixel centroid estimation of (nearly) point target images in cases where the signal-to-noise ratio is low and the signal amplitude and shape vary from frame to frame. In the algorithm, the centroid is calculated over a data window that is matched in width to the image distribution. Fourier analysis is used to explain the dependency of the centroid estimate on the size of the data window, and simulation and experimental results are presented which demonstrate the effects of window size for two different noise models. The effects of window shape were also investigated for uniform and Gaussian-shaped windows. The new algorithm was developed to improve the dynamic range of a close-range photogrammetric tracking system that provides feedback for control of a large gap magnetic suspension system (LGMSS).

Welch, Sharon S.↗

Development of Cryogenic Filter Wheels for the HERSCHEL Photodetector Array Camera & Spectrometer (PACS)

This paper describes the two PACS Filter Wheels that are direct-drive rotational mechanisms operated at a temperature below 5K inside the PACS focal plane unit of the Herschel Satellite. The purpose of the mechanisms is to switch between filters. The rotation axis is pivoted to the support structure via a slightly preloaded pair of ball bearings and driven by a Cryotorquer. Position sensing is realized by a pair of Hall effect sensors. Powerless positioning at the filter positions is achieved by a magnetic ratchet system. The key technologies are the Cryotorquer design and the magnetic ratchet design in the low temperature range. Furthermore, we will report on lessons learned during the development and qualification of the mechanism and the paint.

Koerner, Christian↗

Formation of a magnetic hole above the mirror-instability threshold in a plasma with sloshing ions

Within the framework of paraxial approximation it is shown that in an anisotropic plasma with sloshing ions confined an open-ended system a magnetic hole is formed near the turning point of the sloshing ions above the threshold of the mirror instability. The magnetic field experiences a jump at the hole boundary from the side of the magnetic mirror. For a small excess over the mirror instability threshold, the surface of the discontinuity has the shape of a truncated paraboloid, and the magnitude of the magnetic field jump at the system axis is proportional to the radius of the hole and gradually decreases to zero away of the axis. It is argued that disappearance of the magnetic hole because of the widening of the sloshing ions angular spread in the course of the neutral beam injection results in abrupt anticorrelated changes of the diamagnetic signals measured near the turning point of the sloshing ions and near the midplane of the gas-dynamic trap.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Galfenol Tactile Sensor Array and Visual Mapping System

The smart material, Galfenol, is being explored for its uses as a magnetostrictive material. This project seeks to determine if Galfenol can be used as a tactile sensor in a 2-D grid array, magnetic circuit system. When used within a magnetic circuit, Galfenol indicates induced stress and force as a change in flux, due to a change in permeability of the material. The change in flux is detected by Giant MagnetoResistive (GMR) Sensors, which produce a voltage change proportional to the field change. By using Galfenol in an array, this research attempts to create a sensory area. Galfenol is an alloy made of Iron and Gallium. FexGax, where 15 less than or equal to x less than or equal to 28, creates a material with useful mechanical and transduction attributes (Clark et al and Kell). Galfenol is also distinguished by the crystalline structure of the material. Two types currently exist: single crystal and polycrystalline. Single crystal has higher transduction coefficients than polycrystalline, but is more costly. Polycrystalline Galfenol is currently available as either production or research grade. The designations are related to the sample growth rate with the slower rate being the research grade. The slower growth rate more closely resembles the single crystal Galfenol properties. Galfenol 17.5- 18% research grade is used for this experiment, provided by Etrema Products Inc. The magnetic circuit and sensor array is first built at the macro scale so that the design can be verified. After the macro scale is proven, further development will move the system to the nano-level. Recent advances in nanofabrication have enabled Galfenol to be grown as nanowires. Using the nanowires, research will seek to create high resolution tactile sensors with spatial resolutions similar to human finger tips, but with greater force ranges and sensitivity capabilities (Flatau & Stadler). Possible uses of such systems include robotics and prosthetics.

Hale, Kathleen↗

Conceptual Design of an MTF Space Propulsion System

Most fusion propulsion concepts that have been investigated in the past employ some form of inertial or magnetic confinement separately, and are encumbered by the need for advanced drivers (e.g. laser) or steady-state magnetic confinement systems (e.g. superconductors) that have historically resulted in large, massive spacecraft designs. Here we present a comparatively new approach, Magnetized Target Fusion (MTF), which offers a nearer-term avenue for realizing the tremendous performance benefits of fusion propulsion. MTF attempts to combine the favorable attributes of both inertially and magnetically confined fusion to achieve both efficient and low-cost compressional plasma heating and energy confinement. The key advantage of MTF is its less demanding requirements for driver energy and power processing. Additional features include: 1) very low system masses and volumes, 2) high gain and relatively low waste heat, 3) substantial utilization of energy from product neutrons, 4) efficient, low peak-power drivers based on existing pulsed power technology, and 5) very high I(sub sp), specific power and thrust. MTF overcomes many of the problems associated with traditional fusion techniques, thus making it particularly attractive for space applications. I(sub sp) greater than 50,000 seconds and specific powers greater than 20 kilowatts/kilogram appear feasible using relatively near-term pulse power and plasma gun technology.

Thio, Y. C. Francis↗

Conceptual Design of an MTF Space Propulsion System

Most fusion propulsion concepts that have been investigated in the past employ some form of inertial or magnetic confinement separately, and are encumbered by the need for advanced drivers (e.g. laser) or steady-state magnetic confinement systems (e.g. superconductors) that have historically resulted in large, massive spacecraft designs. Here we present a comparatively new approach, Magnetized Target Fusion (MTF), which offers a nearer-term avenue for realizing the tremendous performance benefits of fusion propulsion. MTF attempts to combine the favorable attributes of both inertially and magnetically confined fusion to achieve both efficient and low-cost compressional plasma heating and energy confinement. The key advantage of MTF is its less demanding requirements for driver energy and power processing. Additional features include: 1) very low system masses and volumes, 2) relatively low waste heat, 3) substantial utilization of energy from product neutrons, 4) efficient, low peak-power drivers based on existing pulsed power technology, 5) very high Isp , specific power and thrust, and 6) relatively affordable R&D pathways. MTF overcomes many of the problems associated with traditional fusion techniques, thus making it particularly attractive for space applications. Isp greater than 50,000 seconds and specific powers greater than 20 kilowatts/kilogram appear feasible using relatively near-term pulse power and plasma gun technology.

Thio, Y. C. F.↗

Synthesis of magnetic and upconversion nanocapsules as multifunctional drug delivery system

Multifunctional hollow nanocapsules with magnetic and upconversion luminescence properties were synthesized. Hollow Fe{sub 3}O{sub 4}@SiO{sub 2} was firstly prepared by using rodlike β-FeOOH as the template followed by silica coating, calcinations and reduction. Then Fe{sub 3}O{sub 4}@SiO{sub 2}@α-NaYF{sub 4}:Yb{sup 3+},Er{sup 3+} nanocapsules (FeSiUCNP) were synthesized by the hydrothermal transformation of the Y(Yb{sup 3+}, Er{sup 3+})(OH)CO{sub 3} (YOC) deposited onto the surface of nanocapsules through a urea-assisted homogeneous precipitation method. The hollow nanocapsules with porous structure provide space and entrance for the drug molecules. Due to the outside shell of α-NaYF{sub 4}:Yb{sup 3+}, Er{sup 3+}, the nanomaterial shows upconverting red emission upon 980 nm NIR-light excitation. Moreover, the nanocomposites with hollow magnetite core exhibit a high relaxivity with r{sub 2} value of 183 mM{sup −1} s{sup −1}, which reveal the potential as T{sub 2}-weighted contrast agents for magnetic resonance imaging (MRI). The as-prepared nanocapsules can be performed as anti-cancer drug carriers for investigation of drug loading/release properties, which demonstrated a sustained drug release pattern and a comparable cytotoxicity with free doxorubicin (DOX). The multifunctional nanocapsules incorporated upconverting luminescence, T{sub 2}-weighted MRI imaging and drug targeting delivery modalities have great potential for theranostic applications in cancer treatment. - Graphical abstract: Multifunctional hollow nanocapsules with upconverting luminescence, T{sub 2}-weighted MRI imaging and drug targeting delivery modalities were synthesized for cancer treatment. - Highlights: • Multifunctional porous Fe{sub 3}O{sub 4}@SiO{sub 2}@α-NaYF{sub 4}:Yb{sup 3+},Er{sup 3+} nanocapsules were synthesized. • The nanocapsules show upconverting red emission upon 980 nm NIR-light excitation. • The nanocapsules exihibit potential as T{sub 2}-weighted contrast agents for MRI. • The DOX loaded nanocapsules demonstrated a comparable cytotoxicity with free DOX.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

INDUCED MAXIMUM MAGNETIC FIELD IN COSMIC OUTFLOW SYSTEM BY A RELATIVISTIC CURRENT FILAMENTATION INSTABILITY: EXACT ANALYTICAL MODEL

We present an analytical study of current filamentation instability (CFI) in a fully relativistic cold plasma system, including arbitrary currents. For our purposes, we employ the cold fluid equations, together with Maxwell's equations as well as the plasma shell concept and boost frame method, to obtain an exact solution of the instability growth rate. A simple relation is found for the maximum growth rate of the CFI (for any arbitrary current system), which remarkably is used to calculate the large magnitude of an induced magnetic field in astrophysical environments such as active galactic nuclei (AGNs), microquasars, supernova remnants (SNRs), and stellar winds. We find that the magnetic field is amplified in the SNR up to the level required to justify the recent discovery of the year-scale variability in the X-ray emission of SNRs. Also, the maximum magnetic field of two and three orders higher (or two orders lower) than that of the SNR has been derived for microquasars and AGNs (or stellar winds), respectively. Moreover, making use of the exact analytical solution of the CFI, it is shown that the maximum magnetic field up to around 10{sup 8} G can be detected from a classical cold counterstreaming system after a saturation time.

79 ASTRONOMY AND ASTROPHYSICS↗

Final Report for contract DE-SC0010151, "A Cost-Effective Oxygen Separation System Based on Open Gradient Magnetic Field by Polymer Beads"

At present much of the oxygen enrichment market is based primarily on cryogenic systems, ion transport membranes made of ceramics, or polymer membranes technologies. All these methods have some positive and some negative attributes, but remain too expensive for the cost effective production of pure oxygen needed for clean renewable energy conversion projects. In a very successful Phase I period, the ITN-TAMU team accomplished the completion of most of the sub-tasks on oxygen separation based on our proposed magnetic field gradients. Theoretical and computer simulation data under different conditions of flow rates, magnetic flux, magnetic beads packing density, pressure and temperature have resulted very valuable observations. Chitosan based polymer magnetic beads showed the best results for uniformity and column packing. Due to limited magnetic force of 1 Tesla, we were restricted to use only single small column of magnetic beads and limited air pressure with controlled flow rate. We also fabricated smaller sized beads column with metal and clear plastic frames to be used for more concentrated packed capacity. Beads made with rare earth Neodymium were not uniform and were quite brittle. Different surfactants have minimized the effect of the de-aggregation of polymer magnetic beads. This Phase I development work also included overcoming key packaging hurdles such as high packing capacity of magnetic polymer beads and formation of consistent batch of magnetic beads. Market and commercialization studies were also initiated to show that there is a growing market for the proposed cost-effective oxygen separation system for energy conversion projects.

20 FOSSIL-FUELED POWER PLANTS↗

Effect of superconducting solenoid model cores on spanwise iron magnet roll control

Compared with conventional ferromagnetic fuselage cores, superconducting solenoid cores appear to offer significant reductions in the projected cost of a large wind tunnel magnetic suspension and balance system. The provision of sufficient magnetic roll torque capability has been a long-standing problem with all magnetic suspension and balance systems; and the spanwise iron magnet scheme appears to be the most powerful system available. This scheme utilizes iron cores which are installed in the wings of the model. It was anticipated that the magnetization of these cores, and hence the roll torque generated, would be affected by the powerful external magnetic field of the superconducting solenoid. A preliminary study has been made of the effect of the superconducting solenoid fuselage model core concept on the spanwise iron magnet roll torque generation schemes. Computed data for one representative configuration indicate that reductions in available roll torque occur over a range of applied magnetic field levels. These results indicate that a 30-percent increase in roll electromagnet capacity over that previously determined will be required for a representative 8-foot wind tunnel magnetic suspension and balance system design.

Britcher, C. P.↗

Research Related to Multi Degree of Freedom Magnetic Suspensions

This thesis covers the activities associated with (1) recommissioning of the 6-inch Magnetic Suspension and Balance System (MSBS) and (2) enhancing the Annular Suspension and Pointing System (ASPS). These activities continue the program of research in the multi degree of freedom magnetic suspension program at Old Dominion University. The 6-inch MSBS is a large gap magnetic suspension system used as a model support and balance system in wind tunnels. The first stage of recommissioning of the 6-inch MSBS for the 6-inch subsonic wind tunnel is performed. Experimental data and computational results for the magnetic field distribution of the MSBS are given and compared with the estimated magnetic field strength. The comparison indicates that the magnet system is still operating as designed. The Electromagnetic Position Sensor used in the 6-inch MSBS is analyzed before its find reinstatement. The ASPS is a small gap magnetic suspension system providing orientation, mechanical isolation and fine pointing of space payloads. The control system of the ASPS is improved by designing a new code to realize red time control over the system. The original Proportional-Derivative controller is upgraded to a Proportional-Integral-Derivative controller. This progress leads to a system which is more stable and robust with less noise. This new controller is generic and can be adapted to the 6-inch MSBS. Finally, future work on these two systems is proposed.

Britcher, Colin↗

Challenges in Continuous In-Field Critical Current Testing of High-Temperature Superconducting Tapes: Thermal and Mechanical Perspectives

High-temperature superconductors (HTS) are essential for ultra-high-field applications requiring exceptional current-carrying capacity under extreme conditions. However, systematic characterization of critical current in long-length conductors remains challenging due to complex thermal, electromag netic, and mechanical interactions during continuous testing. This study reports the development of a continuous in-field magnetization testing system for position-dependent critical current measurement in HTS tapes at 20 K under 7.5 T fields applied normal to the tape plane, enabling identification of performance-limiting regions that could compromise magnet stability. Here, the system addresses two fundamental challenges inherent to cryogenic reel to-reel testing. First, thermal management requires continuous cooling of a moving conductor to 20 K, achieved through liquid nitrogen precooling combined with a 100 W@20 K Gifford McMahon cryocooler. Second, screening currents in high fields generate Lorentz forces that induce twisting, bowing, and potential delamination. To mitigate these risks, we propose mechanical reinforcement and active current density suppression strategies. Numerical simulations using the stream function formulation reveal four primary failure modes: frictional heating at guide interfaces, unstable equilibria causing deformation, transverse current-induced stresses at guide transitions, and unsupported forces in vertical spans. Our mitigation strategies include PTFE coated guides to minimize friction, spring-loaded stabilization mechanisms to maintain tape alignment, controlled pre-heating using the liquid nitrogen thermal jacket to suppress critical current at stress points, and optimized guide positioning to minimize force accumulation. The experimental system is nearing completion, with testing planned to commence within two months. Preliminary validation at 65 K under 0.5 T demonstrates strong correlation between simulation-predicted mechanical instabilities and observed critical current variations during conductor tran sitions through the measurement region. These findings establish a robust foundation for quality assurance protocols essential to next-generation superconducting magnet applications.

Chen, Siwei [Princeton Plasma Physics Laboratory (↗

The magnetic order of a manganese vanadate system with two-dimensional striped triangular lattice

Results of magnetization and neutron diffraction measurements of the manganese vanadate system Mn 5 (VO 4 ) 2 (OH) 4 are reported. The crystal structure of this compound contains triangular [Mn 3 O 13 ] building blocks that produce two-dimensional Mn 2+ magnetic networks with striped triangular topologies. The Mn sheets are connected through the nonmagnetic vanadate tetrahedra extending along the a-axis. Magnetization measurements performed on single crystals reveal the onset of a long-range antiferromagnetic order below approximately 45 K. The magnetic structure is Néel-type with nearest-neighbor Mn atoms coupled via three or four antiferromagnetic bonds. The magnetic moments are confined within the layers and are oriented parallel to the b direction. In conclusion, the magnitudes of ordered moments are reduced, presumably by geometrical frustration and the low-dimensionality of the lattice structure.

36 MATERIALS SCIENCE↗

Measurement of the Magnet Blocks for SSRF Insertion Devices

Two in-vacuum undulators IVU25s and one elliptically polarized undulator EPU100 have been developed for SSRF. Two IVU25s with the same hybrid design contain about 640 Sm{sub 2}Co{sub 17} magnet blocks and the dimension of blocks is 65 Wx25 Hx9 D. The EPU100 of the APPLE-II type contains about 690 NdFeB magnet blocks with the dimension of 35 Wx35 Hx25 D. This paper describes the magnetic measurements of these magnet blocks with the Helmholtz coil measurement system for IVU25 magnet blocks and the Hall probe measurement system for EPU100 magnet blocks. The measured maximum magnetic moment deviation and the maximum angle deviation are less than {+-}1.0% and 1.1 deg. respectively both for Sm{sub 2}Co{sub 17} blocks and NdFeB blocks and satisfy the specifications of undulators.

43 PARTICLE ACCELERATORS↗

Initial state q q g correlations as a background for the chiral magnetic effect in collision of small systems

Motivated by understanding the background to chiral magnetic effect in proton-nucleus collisions from first principles, we compute the three particle correlation in the projectile wave function. We extract the correlations between two quarks and one gluon in the framework of the color glass condensate. This is related to the same-charge correlation of the conventional observable for the chiral magnetic effect. We show that there are two different contributions to this correlation function. One contribution is rapidity-independent and as such can be identified with the pedestal; while the other displays rather strong rapidity dependence. The pedestal contribution and the rapidity-dependent contribution at large rapidity separation between the two quarks result in the negative same charge correlations, while at small rapidity separation the second contribution changes sign. We argue that the computed initial state correlations might be partially responsible for the experimentally observed signal in proton-nucleus collisions.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

System identification of the Large-Angle Magnetic Suspension Test Fixture (LAMSTF)

The Large-Angle Magnetic Suspension Test Fixture (LAMSTF), a laboratory-scale research project to demonstrate the magnetic suspension of objects over wide ranges of attitudes, has been developed. This system represents a scaled model of a planned Large-Gap Magnetic Suspension System (LGMSS). The LAMSTF consists of a small cylindrical permanent magnet suspended element which is levitated above a planar array of five electromagnets mounted in a circular configuration. The cylinder is a rigid body and can be controlled to move in five independent degrees of freedom. Six position variables are sensed indirectly by using infrared light-emitting diodes and light-receiving phototransistors. The motion of the suspended cylinder is in general nonlinear and hence only the linear, time-invariant perturbed motion about an equilibrium state is considered. One of the main challenges in this project is the control of the suspended element over a wide range of orientations. An accurate dynamic model plays an essential role in controller design. The analytical model is first derived and open-loop characteristics discussed. The system is shown to be highly unstable and requires feedback control for system identification. Projection filters are first proposed to identify the state space model from closed-loop input/output test data in the time domain. This method is then extended to identify linear systems from the frequency test data. A canonical transformation matrix is also derived to transform the identified state space model into the physical coordinate. The LAMSTF system is stabilized by using a linear quadratic regulator (LQR) feedback controller for closed-loop identification. The rate information is obtained by calculating the back difference of the sensed position signals. Only the closed-loop random input/output data are recorded. Preliminary results from numerical simulations demonstrate that the identified system model is fairly accurate from either time domain or frequency-domain data. Experiments will be performed to validate the proposed closed-loop identification algorithms.

Huang, Jen-Kuang↗