Search NASA⌕ Search

SEARCH · Search NASA

Results for “MAGNETIC RESONANCE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,189 records · Page 66

Specialized diamond materials for NMR applications

Polarizable diamond materials and methods for obtaining nuclear magnetic resonance spectra of samples external to the diamond materials are described. The diamond materials can include 12C, 13C, substitutional nitrogen, and nitrogen vacancy defects in a crystalline lattice, wherein the substitutional nitrogen concentration is between 10 ppm and 200 ppm, the nitrogen vacancy concentration is between 10 ppb and 10 ppm, and the 13C concentration is greater than 1.1% and not more than 25%. Methods for obtaining nuclear magnetic resonance spectra can include optically pumping a diamond material to generate electron spin hyperpolarization in nitrogen vacancy centers, transferring the electron spin hyperpolarization to nuclei of the sample, and generating a nuclear magnetic resonance spectrum by applying a magnetic field to the sample, exciting the sample with a radio frequency pulse, and detecting a nuclear magnetic resonance response from the sample.

Parker, Alfred↗

NH3-SCR on Cu, Fe and Cu+Fe exchanged Beta and SSZ-13 catalysts: hydrothermal aging and propylene poisoning effects

Cu, Fe and Cu+Fe ion exchanged Beta and SSZ-13 catalysts were prepared by solution ion exchange using commercial NH4/Beta, and NH4/SSZ-13 that was prepared in-house. To study hydrothermal aging effects, Beta supported catalysts were aged hydrothermally at 700 C and SSZ-13 supported catalysts were aged at 750 C. In order to reveal the effects of Fe addition in the co-exchanged catalysts, these catalysts were characterized by means of powder X-ray diffraction (XRD), N2 adsorption-desorption, electron paramagnetic resonance (EPR), 27Al-nuclear magnetic resonance (27Al-NMR) and propylene coking followed with temperature programmed reaction (TPR), and further tested with standard NH3-SCR with and without the presence of propylene. Collectively, the catalyst characterizations and reaction testing indicated minor beneficial effects of Fe addition in Cu,Fe/Beta, where NH3-SCR activity, N2 selectivity and hydrothermal stability were all slightly improved. In contrast, Fe addition did not show apparent beneficial effects in low-temperature SCR for the Cu,Fe/SSZ-13 case. At elevated reaction temperatures, however, the presence of Fe indeed considerably improved NO conversion and N2 selectivity for the hydrothermally aged Cu,Fe/SSZ-13 catalyst in the presence of propylene. The authors from Pacific Northwest National Laboratory (PNNL) gratefully acknowledge the US Department of Energy (DOE), Energy Efficiency and Renewable Energy, Vehicle Technologies Office for the support of this work. The research described in this paper was performed in the Environmental Molecular Sciences Laboratory (EMSL), a national scientific user facility sponsored by the DOE’s Office of Biological and Environmental Research and located at PNNL. PNNL is operated for the US DOE by Battelle. The authors from East China University of Science and Technology acknowledge support from National Basic Research Program of China (2013CB933200), National Natural Science Foundation of China (21577035, 21577034), Commission of Science and Technology of Shanghai Municipality (15DZ1205305) and 111 Project (B08021). Aiyong Wang also gratefully acknowledges the China Scholarship Council for a Joint-Training Scholarship Program with PNNL.

Wang, Aiyong↗

Measurement with microscopic MRI and simulation of flow in different aneurysm models

Purpose: The impact and the development of aneurysms depend to a significant degree on the exchange of liquid between the regular vessel and the pathological extension. A better understanding of this process will lead to improved prediction capabilities. The aim of the current study was to investigate fluid-exchange in aneurysm models of different complexities by combining microscopic magnetic resonance measurements with numerical simulations. In order to evaluate the accuracy and applicability of these methods, the fluid-exchange process between the unaltered vessel lumen and the aneurysm phantoms was analyzed quantitatively using high spatial resolution. Methods: Magnetic resonance flow imaging was used to visualize fluid-exchange in two different models produced with a 3D printer. One model of an aneurysm was based on histological findings. The flow distribution in the different models was measured on a microscopic scale using time of flight magnetic resonance imaging. The whole experiment was simulated using fast graphics processing unit-based numerical simulations. The obtained simulation results were compared qualitatively and quantitatively with the magnetic resonance imaging measurements, taking into account flow and spin–lattice relaxation. Results: The results of both presented methods compared well for the used aneurysm models and the chosen flow distributions. The results from the fluid-exchange analysis showed comparable characteristics concerning measurement and simulation. Similar symmetry behavior was observed. Based on these results, the amount of fluid-exchange was calculated. Depending on the geometry of the models, 7% to 45% of the liquid was exchanged per second. Conclusions: The result of the numerical simulations coincides well with the experimentally determined velocity field. The rate of fluid-exchange between vessel and aneurysm was well-predicted. Hence, the results obtained by simulation could be validated by the experiment. The observed deviations can be caused by the noise in the measurement and by the limited resolution of the simulation. The resulting differences are small enough to allow reliable predictions of the flow distribution in vessels with stents and for pulsed blood flow.

60 APPLIED LIFE SCIENCES↗

A Universal Method for Fishing Target Proteins from Mixtures of Biomolecules using Isothermal Titration Calorimetry

The most challenging tasks in biology include the identification of (1) the orphan receptor for a ligand, (2) the ligand for an orphan receptor protein, and (3) the target protein(s) for a given drug or a lead compound that are critical for the pharmacological or side effects. At present, several approaches are available, including cell- or animal-based assays, affinity labeling, solid-phase binding assays, surface plasmon resonance, and nuclear magnetic resonance. Most of these techniques are not easy to apply when the target protein is unknown and the compound is not amenable to labeling, chemical modification, or immobilization. Here we demonstrate a new universal method for fishing orphan target proteins from a complex mixture of biomolecules using isothermal titration calorimetry (ITC) as a tracking tool. We took snake venom, a crude mixture of several hundred proteins/peptides, as a model to demonstrate our proposed ITC method in tracking the isolation and purification of two distinct target proteins, a major component and a minor component. Identities of fished out target proteins were confirmed by amino acid sequencing and inhibition assays. This method has the potential to make a significant advancement in the area of identifying orphan target proteins and inhibitor screening in drug discovery and characterization.

59 BASIC BIOLOGICAL SCIENCES↗

Spin-dependent electron transport in manganite bicrystal junctions

Magnetic bicrystal films and junctions of magnetic La{sub 0.67}Sr{sub 0.33}MnO{sub 3} (LSMO) and La{sub 0.67}Ca{sub 0.33}MnO{sub 3} (LCMO) films epitaxially grown on NdGaO{sub 3} substrates with the (110) planes of their two parts misoriented (tilted) at angles of 12 Degree-Sign , 22 Degree-Sign , 28 Degree-Sign , and 38 Degree-Sign are investigated. For comparison, bicrystal boundaries with a 90 Degree-Sign misorientation of the axes of the NdGaO{sub 3} (110) planes were fabricated. The directions of the axes and the magnetic anisotropy constants of the films on both sides of the boundary are determined by two independent techniques of magnetic resonance spectroscopy. The magnetic misorientation of the axes in the substrate plane has been found to be much smaller than the crystallographic misorientation for tilted bicrystal boundaries, while the crystallographic and magnetic misorientation angles coincide for boundaries with rotation of the axes. An increase in the magnetoresistance and characteristic resistance of bicrystal junctions with increasing misorientation angle was observed experimentally. The magnetoresistance of bicrystal junctions has been calculated by taking into account the uniaxial anisotropy, which has allowed the contributions from the tunneling and anisotropic magnetoresistances to be separated. The largest tunneling magnetoresistance was observed on LCMO bicrystal junctions, in which the characteristic resistance of the boundary is higher than that in LSMO boundaries.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

NMR measurement of hydrodynamic dispersion in porous media subject to biofilm mediated precipitation reactions

Noninvasive measurements of hydrodynamic dispersion by nuclear magnetic resonance (NMR) are made in a model porous system before and after a biologically mediated precipitation reaction. Traditional magnetic resonance imaging (MRI) was unable to detect the small scale changes in pore structure visualized during light microscopy analysis after destructive sampling of the porous medium. However, pulse gradient spin echo nuclear magnetic resonance (PGSE NMR) measurements clearly indicated a change in hydrodynamics including increased pore scale mixing. These changes were detected through time-dependent measurement of the propagator by PGSE NMR. The dynamics indicate an increased pore scale mixing which alters the pre-asymptotic approach to asymptotic Gaussian dynamics governed by the advection diffusion equation. The methods described here can be used in the future to directly measure the transport of solutes in biomineral-affected porous media and contribute towards reactive transport models, which take into account the influence of pore scale changes in hydrodynamics.

54 ENVIRONMENTAL SCIENCES↗

Pairing Toroidal and Magnetic Dipole Resonances in Elliptic Dielectric Rod Metasurfaces for Reconfigurable Wavefront Manipulation in Reflection

Abstract A novel approach for reconfigurable wavefront manipulation with gradient metasurfaces based on permittivity‐modulated elliptic dielectric rods is proposed. It is shown that the required 2π phase span in the local electromagnetic response of the metasurface can be achieved by pairing the lowest magnetic dipole Mie resonance with a toroidal dipole Mie resonance, instead of using the lowest two Mie resonances corresponding to fundamental electric and magnetic dipole resonances as customarily exercised. This approach allows for the precise matching of both the resonance frequencies and quality factors. Moreover, the accurate matching is preserved if the rod permittivity is varied, allowing for constructing reconfigurable gradient metasurfaces by locally modulating the permittivity in each rod. Highly efficient tunable beam steering and beam focusing with ultrashort focal lengths are numerically demonstrated, highlighting the advantage of the low‐profile metasurfaces over bulky conventional lenses. Notably, despite using a matched pair of Mie resonances, the presence of an electric polarizability background allows to perform the wavefront shaping operations in reflection, rather than transmission. This has the advantage that any control circuitry necessary in an experimental realization can be accommodated behind the metasurface without affecting the electromagnetic response.

36 MATERIALS SCIENCE↗

In Vivo Noninvasive Analysis of Human Forearm Muscle Function and Fatigue: Applications to EVA Operations and Training Maneuvers

Forearm muscle fatigue is one of the major limiting factors affecting endurance during performance of deep-space extravehicular activity (EVA) by crew members. Magnetic resonance (MR) provides in vivo noninvasive analysis of tissue level metabolism and fluid exchange dynamics in exercised forearm muscles through the monitoring of proton magnetic resonance imaging (MRI) and phosphorus magnetic resonance spectroscopy (P-31-MRS) parameter variations. Using a space glove box and EVA simulation protocols, we conducted a preliminary MRS/MRI study in a small group of human test subjects during submaximal exercise and recovery and following exhaustive exercise. In assessing simulated EVA-related muscle fatigue and function, this pilot study revealed substantial changes in the MR image longitudinal relaxation times (T2) as an indicator of specific muscle activation and proton flux as well as changes in spectral phosphocreatine-to-phosphate (PCr/Pi) levels as a function of tissue bioenergetic potential.

Fotedar, L. K.↗

Error field measurements with rotating RMP fields for DIII-D H-mode

3D magnetic sensors are employed to identify the amplitude and toroidal phase of error fields (EF) by analyzing the torque balance for magnetic islands entrained by rotating resonant magnetic perturbations (RMPs) in DIII-D H-mode plasmas. This technique of torque balance allows for efficient error field identification, offering a valuable tool for scenario-specific and optimized error field compensation (EFC) and requires only magnetic diagnostics. The torque balance used in this work includes the contribution from electromagnetic torque due to error fields, wall response, RMP fields, and viscous. Results show that viscous torque plays a crucial role, particularly during locked modes and H-mode plasmas, ensuring accurate data fits with lower residuals. The torque balance technique reveals that the L- and H-mode plasmas have distinct EF configurations, and consistent with a model-based EF analysis including MHD response in IPEC and the SURFMN EF simulation. This technique shows great robustness in measuring the intrinsic EF amplitude regardless of its amplitude or toroidal phase. Repeated discharges with EFC disparities exhibit consistent results of intrinsic error field within a reasonable range near the “standard” error field compensation. Additionally, the use of a rotating n = 1 resonant magnetic perturbation offers the advantage of reducing disruption risks by entraining saturated magnetic islands. These findings are instrumental for optimizing EF correction in fusion devices, thereby enhancing tearing mode suppression and overall plasma stability.

3D magnetic sensors↗

Patterns of Retropharyngeal Node Metastasis in Nasopharyngeal Carcinoma

Purpose: To explore the pattern of metastasis to retropharyngeal lymph nodes (RLN) and its relationship with tumor range in nasopharyngeal carcinoma (NPC) patients by using magnetic resonance imaging. Methods and Materials: Magnetic resonance images of 618 NPC patients were reviewed. Nodes were classified as metastatic on the basis of size criteria, the presence of nodal necrosis, and extracapsular spread. Results: A total of 597 involved RLN were detected in 392 patients (63.4%). The sites of RLN metastasis included occipital bone, 37 (6.2%); first cervical vertebra (C1), 453 (75.9%); second cervical vertebra (C2), 104 (17.4%); and third cervical vertebra (C3), 3 (0.5%). The incidence of RLN involvement was less than that of Level IIb node involvement (72.2% vs. 86.5%) in 543 patients with lymphadenopathy. The incidence of RLN metastasis was significantly higher in cases of parapharyngeal space invasion or involvement of Level II, Level III, Level IV, and/or Level V nodes and significantly lower in N0 and Stage I disease. Conversely, the incidence of RLN metastasis did not differ significantly among T1, 2, 3, and 4 disease or among Stage II, III, and IV disease. Conclusions: Level IIb nodes, rather than RLN, seem to be the first-echelon nodes in NPC. The incidence of RLN metastasis decreases steadily from level C1 to level C3. Retropharyngeal lymph node metastasis correlates well with involvement of the parapharyngeal space and metastases to Level II, III, IV, and/or V nodes but not with T stage.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Switchable wavelength-selective and diffuse metamaterial absorber/emitter with a phase transition spacer layer

We numerically demonstrate a switchable metamaterial absorber/emitter by thermally turning on or off the excitation of magnetic resonance upon the phase transition of vanadium dioxide (VO{sub 2}). Perfect absorption peak exists around the wavelength of 5 μm when the excitation of magnetic resonance is supported with the insulating VO{sub 2} spacer layer. The wavelength-selective absorption is switched off when the magnetic resonance is disabled with metallic VO{sub 2} that shorts the top and bottom metallic structures. The resonance wavelength can be tuned with different geometry, and the switchable metamaterial exhibits diffuse behaviors at oblique angles. The results would facilitate the design of switchable metamaterials for active control in energy and sensing applications.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Weak Magnetic Field Resonance Effects in Diamond with Nitrogen-Vacancy Centers

The photoluminescence intensity of the ensemble of NV centers in diamond at weak magnetic field was studied. Two resonances were revealed in the region of weak magnetic fields: the first resonance with a width of the order of 20 G, and the second resonance with a width of the order of 180 G. The presence of these optical resonances makes it possible to propose a new concept for creating magnetic field sensors based on a diamond with an ensemble of NV centers without the use of a microwave field.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Decay time characteristics of La2O2S:Eu and La2O2S:Tb for use within an optical sensor for human skin temperature measurement

We focus on the development of a remote temperature sensing technology, i.e., an optical laser-based sensor, using thermographic phosphors for medical applications, particularly within an electromagnetically hostile magnetic resonance imaging (MRI) environment. A MRI scanner uses a strong magnetic field and radio waves to generate images of the inside of the body. The quality of the image improves with increasing magnetic resonance; however, the drawback of applying a greater magnetic strength is the inducement of heat into the body tissue. Therefore, monitoring the patient's temperature inside MRI is vital, but until now, a practical solution for temperature measurement did not exist. We show europium doped lanthanum oxysulphide (La2O2S:Eu) and terbium doped lanthanum oxysulphide (La2O2S:Tb) are both temperature sensitive to a low temperature range of 10-50 deg. C when under ultraviolet (UV) excitation. The emission spectra and decay time characteristics of these phosphors were demonstrated. The results indicate that La2O2S:Eu has a quenching rate of 13.7 m deg. C{sup -1} and 4 m deg. C{sup -1} at 512 nm and 538 nm, respectively. In addition, La2O2S:Tb has a lower quenching rate of 4.19 m deg. C{sup -1} at 548 nm due to its faster decay time.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Method of performing MRI with an atomic magnetometer

A method and apparatus are provided for performing an in-situ magnetic resonance imaging of an object. The method includes the steps of providing an atomic magnetometer, coupling a magnetic field generated by magnetically resonating samples of the object through a flux transformer to the atomic magnetometer and measuring a magnetic resonance of the atomic magnetometer.

47 OTHER INSTRUMENTATION↗

Method of performing MRI with an atomic magnetometer

A method and apparatus are provided for performing an in-situ magnetic resonance imaging of an object. The method includes the steps of providing an atomic magnetometer, coupling a magnetic field generated by magnetically resonating samples of the object through a flux transformer to the atomic magnetometer and measuring a magnetic resonance of the atomic magnetometer.

47 OTHER INSTRUMENTATION↗

Ferromagnetic resonance and magnetic studies of cores 60009/60010 and 60003 - Compositional and surface-exposure stratigraphy

Ferromagnetic resonance and static magnetic measurements were made on 131 samples from core 60009/60010 and on 40 samples from section 60003 of the Apollo 16 deep drill core. These studies provided depth profiles for composition, in terms of the concentration of FeO, and relative surface exposure age (or maturity), in terms of the values of the specific FMR intensity normalized to the FeO content. For core 60009/60010, the concentration of FeO ranged from about 1.6 wt.% to 5.8 wt.% with a mean value of 4.6 wt.% and the maturity ranged from immature to mature with most of the soils being submature. A systematic decrease in maturity from the lunar surface to a depth of about 12.5 cm was observed in core section 60010. For core section 60003, the concentration of FeO ranged from about 5.2 wt.% to 7.5 wt.% with a mean value of 6.4 wt.% and the maturity ranged from submature to mature with most of the soils being mature.

Morris, R. V.↗

Magnesium silicate dissolution investigated by Si-29 MAS, H-1-Si-29 CPMAS, Mg-25 QCPMG NMR.

Olivine-(Mg,Fe){sub 2}SiO{sub 4}-has been the subject of frequent investigation in the earth sciences because of its simple structure and rapid dissolution kinetics. Several studies have observed a preferential release of the divalent cation with respect to silicon during weathering under acidic conditions, which has been correlated to the formation of a silicon-rich leached layer. While leached layer formation has been inferred through the changing solution chemistry, a thorough spectroscopic investigation of olivine reacted under acidic conditions has not been conducted. The pure magnesium end member of the olivine series (forsterite-Mg{sub 2}SiO{sub 4}) was chosen for detailed investigations in this study because paramagnetic iron hinders NMR investigations by providing an extra mode of relaxation for neighboring nuclei, causing lineshapes to become significantly broadened and unobservable in the NMR spectrum. For reacting forsterite, spectroscopic interrogations using nuclear magnetic resonance (NMR) can elucidate the changing magnesium coordination and bonding environment. In this study, we combine analysis of the changing solution chemistry with advanced NMR techniques ({sup 29}Si MAS, {sup 1}H-{sup 29}Si CP MAS, {sup 25}Mg QCPMG, and {sup 1}H-{sup 25}Mg CP QCPMG NMR) to probe leached layer formation and secondary phase precipitation during the dissolution of forsterite at 150 C.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗