Search NASA⌕ Search

SEARCH · Search NASA

Results for “MULTIPLICITY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,189 records · Page 66

Multiple plates subducting beneath Colombia, as illuminated by seismicity and velocity from the joint inversion of seismic and gravity data

Subduction beneath the northernmost Andes in Colombia is complex. Based on seismicity distributions, multiple segments of slab appear to be subducting, and arc volcanism ceases north of 5° N. Here, we illuminate the subduction system through hypocentral relocations and Vp and Vs models resulting from the joint inversion of local body wave arrivals, surface wave dispersion measurements, and gravity data. The simultaneous use of multiple data types takes advantage of the differing sensitivities of each data type, resulting in velocity models that have improved resolution at both shallower and deeper depths than would result from traditional travel time tomography alone. The relocated earthquake dataset and velocity model clearly indicate a tear in the Nazca slab at 5° N, corresponding to a 250-km shift in slab seismicity and the termination of arc volcanism. North of this tear, the slab is flat, and it comprises slabs of two sources: the Nazca and Caribbean plates. The Bucaramanga nest, a small region of among the most intense intermediate-depth seismicity globally, is associated with the boundary between these two plates and possibly with a zone of melting or elevated water content, based on reduced Vp and increased Vp/Vs. As a result, we also use relocated seismicity to identify two new faults in the South American plate, one related to plate convergence and one highlighted by induced seismicity.

58 GEOSCIENCES↗

Enhanced dynamic equivalent identification method of large-scale power systems using multiple events

The increasing complexity of the interconnected power system makes high-fidelity dynamic simulation models computationally more intensive. To improve computation efficiency, model reduction techniques have been investigated to only preserve the dynamics in a limited area of interest (study area), while deriving equivalent representation for the external area. For this purpose, a measurement-based reduction approach using system identification techniques has been previously proposed. Accordingly, external areas are represented by dynamic equivalent loads using transfer function estimation. In this paper, in order to enhance the accuracy of the reduced model in preserving dynamics of the study area, multiple “grid” events of different types and at different locations are considered for identifying the parameters of the equivalent loads. Additionally, case studies are carried out in the NPCC 140-bus system. Comparisons are made between multiple events training and single event training, highlighting the advantages of the proposed method in providing a better representation of the grid dynamics under different operating conditions.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Numerical investigation of mass flow rate effects on multiplicity of detonation waves within a H 2 /Air rotating detonation combustor

This paper presents results from numerical simulations of a non-premixed hydrogen-air rotating detonation combustor with radial injection. The fuel and air mass flow rate are varied in order to hold a unity global equivalence ratio. The calculations show that multiple detonation waves co-exist when the mass flow rate is increased. Conditional statistics of the detonation structure and combustion processes suggest similarities across co-existing waves. Quantification of the injection response to the rotation of a detonation indicates that at higher flow rate the refill time is short enough to allow for a quick and well mixed composition prior to the new front passage. Details of the combustion characteristics are analyzed. Finally, the results elucidate the correlation between initial injection conditions and detonation multiplicity on the overall physics within the combustor.

08 HYDROGEN↗

Deciphering the multiple deformation mechanisms responsible for sustained work hardening in a FeCrCoNi medium entropy alloy

Two important and desirable properties of materials for most structural applications are high tensile strength and ductility, which typically require high work hardening to delay necking. Here, in this work, we designed and tensile tested a face-centered cubic (fcc) Fe-Cr-Co-Ni medium-entropy alloy in which multiple deformation mechanisms are triggered during tensile loading at different temperatures to induce sustained work hardening. Our strategy involved control of the relative stabilities of the fcc, hcp (hexagonal close-packed), and bcc (body-centered cubic) phases in this quaternary system via high-throughput thermodynamic calculations. This alloy not only exhibits extensive deformation-induced nanotwinning at room temperature, but also displays a two-step sequential phase transformation [γ (fcc) → ε (hcp) martensite → α’ (bcc) martensite] at 77 K, which contrasts with the single-step phase transformation [γ → ε martensite] observed in many other fcc high/medium entropy alloys with a low stacking fault energy. The sequence of phase transformation at 77K was supported by first-principles density functional theory calculations. This work provides new templates for the design of alloys capable of multiple deformation mechanisms for sustained work hardening.

36 MATERIALS SCIENCE↗

A Phase III Study of Conventional Radiation Therapy Plus Thalidomide Versus Conventional Radiation Therapy for Multiple Brain Metastases (RTOG 0118)

Purpose: To compare whole-brain radiation therapy (WBRT) with WBRT combined with thalidomide for patients with brain metastases not amenable to resection or radiosurgery. Patients and Methods: Patients with Zubrod performance status 0-1, MRI-documented multiple (>3), large (>4 cm), or midbrain brain metastases arising from a histopathologically confirmed extracranial primary tumor, and an anticipated survival of >8 weeks were randomized to receive WBRT to a dose of 37.5 Gy in 15 fractions with or without thalidomide during and after WBRT. Prerandomization stratification used Radiation Therapy Oncology Group (RTOG) Recursive Partitioning Analysis (RPA) Class and whether post-WBRT chemotherapy was planned. Endpoints included overall survival, progression-free survival, time to neurocognitive progression, the cause of death, toxicities, and quality of life. A protocol-planned interim analysis documented that the trial had an extremely low probability of ever showing a significant difference favoring the thalidomide arm given the results at the time of the analysis, and it was therefore closed on the basis of predefined statistical guidelines. Results: Enrolled in the study were 332 patients. Of 183 accrued patients, 93 were randomized to receive WBRT alone and 90 to WBRT and thalidomide. Median survival was 3.9 months for both arms. No novel toxicities were seen, but thalidomide was not well tolerated in this population. Forty-eight percent of patients discontinued thalidomide because of side effects. Conclusion: Thalidomide provided no survival benefit for patients with multiple, large, or midbrain metastases when combined with WBRT; nearly half the patients discontinued thalidomide due to side effects.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Image-Guided Total-Marrow Irradiation Using Helical Tomotherapy in Patients With Multiple Myeloma and Acute Leukemia Undergoing Hematopoietic Cell Transplantation

Purpose: Total-body irradiation (TBI) has an important role in patients undergoing hematopoietic cell transplantation (HCT), but is associated with significant toxicities. Targeted TBI using helical tomotherapy results in reduced doses to normal organs, which predicts for reduced toxicities compared with standard TBI. Methods and Materials: Thirteen patients with multiple myeloma were treated in an autologous tandem transplantation Phase I trial with high-dose melphalan, followed 6 weeks later by total-marrow irradiation (TMI) to skeletal bone. Dose levels were 10, 12, 14, and 16 Gy at 2 Gy daily/twice daily. In a separate allogeneic HCT trial, 8 patients (5 with acute myelogenous leukemia, 1 with acute lymphoblastic leukemia, 1 with non-Hodgkin's lymphoma, and 1 with multiple myeloma) were treated with TMI plus total lymphoid irradiation plus splenic radiotherapy to 12 Gy (1.5 Gy twice daily) combined with fludarabine/melphalan. Results: For the 13 patients in the tandem autologous HCT trial, median age was 54 years (range, 42-66 years). Median organ doses were 15-65% that of the gross target volume dose. Primarily Grades 1-2 acute toxicities were observed. Six patients reported no vomiting; 9 patients, no mucositis; 6 patients, no fatigue; and 8 patients, no diarrhea. For the 8 patients in the allogeneic HCT trial, median age was 52 years (range, 24-61 years). Grades 2-3 nausea, vomiting, mucositis, and diarrhea were observed. In both trials, no Grade 4 nonhematologic toxicity was observed, and all patients underwent successful engraftment. Conclusions: This study shows that TMI using helical tomotherapy is clinically feasible. The reduced acute toxicities observed compare favorably with those seen with standard TBI. Initial results are encouraging and warrant further evaluation as a method to dose escalate with acceptable toxicity or to offer TBI-containing regimens to patients unable to tolerate standard approaches.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Whole-Brain Radiotherapy With Simultaneous Integrated Boost to Multiple Brain Metastases Using Volumetric Modulated Arc Therapy

Purpose: Volumetric modulated arc therapy (RapidArc [RA]; Varian Medical Systems, Palo Alto, CA) allows for the generation of intensity-modulated dose distributions by use of a single gantry rotation. We used RA to plan and deliver whole-brain radiotherapy (WBRT) with a simultaneous integrated boost in patients with multiple brain metastases. Methods and Materials: Composite RA plans were generated for 8 patients, consisting of WBRT (20 Gy in 5 fractions) with an integrated boost, also 20 Gy in 5 fractions, to Brain metastases, and clinically delivered in 3 patients. Summated gross tumor volumes were 1.0 to 37.5 cm{sup 3}. RA plans were measured in a solid water phantom by use of Gafchromic films (International Specialty Products, Wayne, NJ). Results: Composite RA plans could be generated within 1 hour. Two arcs were needed to deliver the mean of 1,600 monitor units with a mean 'beam-on' time of 180 seconds. RA plans showed excellent coverage of planning target volume for WBRT and planning target volume for the boost, with mean volumes receiving at least 95% of the prescribed dose of 100% and 99.8%, respectively. The mean conformity index was 1.36. Composite plans showed much steeper dose gradients outside Brain metastases than plans with a conventional summation of WBRT and radiosurgery. Comparison of calculated and measured doses showed a mean gamma for double-arc plans of 0.30, and the area with a gamma larger than 1 was 2%. In-room times for clinical RA sessions were approximately 20 minutes for each patient. Conclusions: RA treatment planning and delivery of integrated plans of WBRT and boosts to multiple brain metastases is a rapid and accurate technique that has a higher conformity index than conventional summation of WBRT and radiosurgery boost.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Radiation Treatment Planning Using Positron Emission and Computed Tomography for Lung and Pharyngeal Cancers: A Multiple-Threshold Method for [{sup 18}F]Fluoro-2-Deoxyglucose Activity

Purpose: Clinical applicability of a multiple-threshold method for [{sup 18}F]fluoro-2-deoxyglucose (FDG) activity in radiation treatment planning was evaluated. Methods and Materials: A total of 32 patients who underwent positron emission and computed tomography (PET/CT) simulation were included; 18 patients had lung cancer, and 14 patients had pharyngeal cancer. For tumors of <=2 cm, 2 to 5 cm, and >5 cm, thresholds were defined as 2.5 standardized uptake value (SUV), 35%, and 20% of the maximum FDG activity, respectively. The cervical and mediastinal lymph nodes with the shortest axial diameter of >=10 mm were considered to be metastatic on CT (LNCT). The retropharyngeal lymph nodes with the shortest axial diameter of >=5 mm on CT and MRI were also defined as metastatic. Lymph nodes showing maximum FDG activity greater than the adopted thresholds for radiation therapy planning were designated LNPET-RTP, and lymph nodes with a maximum FDG activity of >=2.5 SUV were regarded as malignant and were designated LNPET-2.5 SUV. Results: The sizes of gross tumor volumes on PET (GTVPET) with the adopted thresholds in the axial plane were visually well fitted to those of GTV on CT (GTVCT). However, the volumes of GTVPET were larger than those of GTVCT, with significant differences (p < 0.0001) for lung cancer, due to respiratory motion. For lung cancer, the numbers of LNCT, LNPET-RTP, and LNPET-2.5 SUV were 29, 28, and 34, respectively. For pharyngeal cancer, the numbers of LNCT, LNPET-RTP, and LNPET-2.5 SUV were 14, 9, and 15, respectively. Conclusions: Our multiple thresholds were applicable for delineating the primary target on PET/CT simulation. However, these thresholds were inaccurate for depicting malignant lymph nodes.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Is Local Radiotherapy Still Valuable for Patients With Multiple Intrahepatic Hepatocellular Carcinomas?

Purpose: To investigate whether local radiotherapy (RT) is valuable for patients with multiple hepatocellular carcinomas (HCCs). Methods and Materials: From July 1992 to August 2006, 107 patients with unresectable HCC were treated with local RT after incomplete transcatheter arterial chemoembolization (TACE). The RT field included a main tumor with or without other tumor nodules, depending on the effectiveness of TACE. The median RT dose was 50.4Gy in conventional fractionation. Patients were categorized into four groups: Group 1, single tumor (39 patients); Group 2, multiple tumors within the RT field (25 patients); Group 3, controlled tumors out of the RT field (19 patients); and Group 4, tumors that remained viable out of the RT field (24 patients). Results: Group 1 showed the best survival rate (MST, 35 months; 2-year OS, 60%) and Group 4 the worst (MST, 5 months; 2-year OS, 16%). Group 2 and Group 3 showed similar survival (MST, 13 vs. 19 months; 2-year OS, 35% vs. 46%; p = 0.698). Significantly worse intrahepatic control in Group 4 was observed. The survival in Groups 2 and 3 (MST, 16 months) was significantly different from that in Group 4 (p = 0.004), and was marginally significant compared with that in Group 1 (p = 0.051). Conclusions: Local RT to the main tumor could be applicable in well-controlled intrahepatic tumors out of the RT field. Patients with viable intrahepatic tumors out of the RT field showed worse survival. In future clinical trials, these patients need to be excluded.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Single-Isocenter Frameless Intensity-Modulated Stereotactic Radiosurgery for Simultaneous Treatment of Multiple Brain Metastases: Clinical Experience

Purpose: To describe our clinical experience using a unique single-isocenter technique for frameless intensity-modulated stereotactic radiosurgery (IM-SRS) to treat multiple brain metastases. Methods and Materials: Twenty-six patients with a median of 5 metastases (range, 2-13) underwent optically guided frameless IM-SRS using a single, centrally located isocenter. Median prescription dose was 18 Gy (range, 14-25). Follow-up magnetic resonance imaging (MRI) and clinical examination occurred every 2-4 months. Results: Median follow-up for all patients was 3.3 months (range, 0.2-21.3), with 20 of 26 patients (77%) followed up until their death. For the remaining 6 patients alive at the time of analysis, median follow-up was 14.6 months (range, 9.3-18.0). Total treatment time ranged from 9.0 to 38.9 minutes (median, 21.0). Actuarial 6- and 12-month overall survivals were 50% (95% confidence interval [C.I.], 31-70%) and 38% (95% C.I., 19-56%), respectively. Actuarial 6- and 12-month local control (LC) rates were 97% (95% C.I., 93-100%) and 83% (95% C.I., 71-96%), respectively. Tumors {<=}1.5 cm had a better 6-month LC than those >1.5 cm (98% vs. 90%, p = 0.008). New intracranial metastatic disease occurring outside of the treatment volume was observed in 7 patients. Grade {>=}3 toxicity occurred in 2 patients (8%). Conclusion: Frameless IM-SRS using a single-isocenter approach for treating multiple intracranial metastases can produce clinical outcomes that compare favorably with those of conventional SRS in a much shorter treatment time (<40 minutes). Given its faster treatment time, this technique is appealing to both patients and personnel in busy clinics.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

External-Beam Accelerated Partial Breast Irradiation Using Multiple Proton Beam Configurations

Purpose: To explore multiple proton beam configurations for optimizing dosimetry and minimizing uncertainties for accelerated partial breast irradiation (APBI) and to compare the dosimetry of proton with that of photon radiotherapy for treatment of the same clinical volumes. Methods and Materials: Proton treatment plans were created for 11 sequential patients treated with three-dimensional radiotherapy (3DCRT) photon APBI using passive scattering proton beams (PSPB) and were compared with clinically treated 3DCRT photon plans. Monte Carlo calculations were used to verify the accuracy of the proton dose calculation from the treatment planning system. The impact of range, motion, and setup uncertainty was evaluated with tangential vs. en face beams. Results: Compared with 3DCRT photons, the absolute reduction of the mean of V100 (the volume receiving 100% of prescription dose), V90, V75, V50, and V20 for normal breast using protons are 3.4%, 8.6%, 11.8%, 17.9%, and 23.6%, respectively. For breast skin, with the similar V90 as 3DCRT photons, the proton plan significantly reduced V75, V50, V30, and V10. The proton plan also significantly reduced the dose to the lung and heart. Dose distributions from Monte Carlo simulations demonstrated minimal deviation from the treatment planning system. The tangential beam configuration showed significantly less dose fluctuation in the chest wall region but was more vulnerable to respiratory motion than that for the en face beams. Worst-case analysis demonstrated the robustness of designed proton beams with range and patient setup uncertainties. Conclusions: APBI using multiple proton beams spares significantly more normal tissue, including nontarget breast and breast skin, than 3DCRT using photons. It is robust, considering the range and patient setup uncertainties.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Clinical Validation of Atlas-Based Auto-Segmentation of Multiple Target Volumes and Normal Tissue (Swallowing/Mastication) Structures in the Head and Neck

Purpose: To validate and clinically evaluate autocontouring using atlas-based autosegmentation (ABAS) of computed tomography images. Methods and Materials: The data from 10 head-and-neck patients were selected as input for ABAS, and neck levels I-V and 20 organs at risk were manually contoured according to published guidelines. The total contouring times were recorded. Two different ABAS strategies, multiple and single subject, were evaluated, and the similarity of the autocontours with the atlas contours was assessed using Dice coefficients and the mean distances, using the leave-one-out method. For 12 clinically treated patients, 5 experienced observers edited the autosegmented contours. The editing times were recorded. The Dice coefficients and mean distances were calculated among the clinically used contours, autocontours, and edited autocontours. Finally, an expert panel scored all autocontours and the edited autocontours regarding their adequacy relative to the published atlas. Results: The time to autosegment all the structures using ABAS was 7 min/patient. No significant differences were observed in the autosegmentation accuracy for stage N0 and N+ patients. The multisubject atlas performed best, with a Dice coefficient and mean distance of 0.74 and 2 mm, 0.67 and 3 mm, 0.71 and 2 mm, 0.50 and 2 mm, and 0.78 and 2 mm for the salivary glands, neck levels, chewing muscles, swallowing muscles, and spinal cord-brainstem, respectively. The mean Dice coefficient and mean distance of the autocontours vs. the clinical contours was 0.8 and 2.4 mm for the neck levels and salivary glands, respectively. For the autocontours vs. the edited autocontours, the mean Dice coefficient and mean distance was 0.9 and 1.6 mm, respectively. The expert panel scored 100% of the autocontours as a 'minor deviation, editable' or better. The expert panel scored 88% of the edited contours as good compared with 83% of the clinical contours. The total editing time was 66 min. Conclusion: Multiple-subject ABAS of computed tomography images proved to be a useful novel tool in the rapid delineation of target and normal tissues. Although editing of the autocontours is inevitable, a substantial time reduction was achieved using editing, instead of manual contouring (180 vs. 66 min).

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Continued Benefit to Androgen Deprivation Therapy for Prostate Cancer Patients Treated With Dose-Escalated Radiation Therapy Across Multiple Definitions of High-Risk Disease

Purpose: To analyze prognostic factors in patients with high-risk prostate cancer treated with dose-escalated external-beam radiation therapy (EBRT) and androgen deprivation (ADT). Methods and Materials: Between 1998 and 2008 at University of Michigan Medical Center, 718 men were consecutively treated with EBRT to at least 75 Gy. Seven definitions of high-risk prostate cancer, applying to 11-33% of patients, were evaluated. Biochemical failure (BF), salvage ADT use, metastatic progression, and prostate cancer-specific mortality (PCSM) were estimated by the Kaplan-Meier method and Cox proportional hazards regression. Results: Each high-risk definition was associated with increased BF (hazard ratio [HR] 2.8-3.9, p < 0.0001), salvage ADT use (HR 3.9-6.3, p < 0.0001), metastasis (HR 3.7-6.6, p < 0.0001), and PCSM (HR 3.7-16.2, p < 0.0001). Furthermore, an increasing number of high-risk features predicted worse outcome. Adjuvant ADT yielded significant reductions in both metastases (HR 0.19-0.38, p < 0.001) and PCSM (HR 0.38-0.50, p < 0.05) for all high-risk definitions (with the exception of clinical Stage T3-4 disease) but improved BF only for those with elevated Gleason scores (p < 0.03, HR 0.25-0.48). When treated with ADT and dose-escalated EBRT, patients with Gleason scores 8 to 10, without other high-risk features, had 8-year freedom from BF of 74%, freedom from distant metastases of 93%, and cause-specific survival of 92%, with salvage ADT used in 16% of patients. Conclusion: Adjuvant ADT results in a significant improvement in clinical progression and PCSM across multiple definitions of high-risk disease even with dose-escalated EBRT. There is a subset of patients, characterized by multiple high-risk features or the presence of Gleason Pattern 5, who remain at significant risk for metastasis and PCSM despite current treatment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Whole Brain Irradiation With Hippocampal Sparing and Dose Escalation on Multiple Brain Metastases: A Planning Study on Treatment Concepts

Purpose: To develop a new treatment planning strategy in patients with multiple brain metastases. The goal was to perform whole brain irradiation (WBI) with hippocampal sparing and dose escalation on multiple brain metastases. Two treatment concepts were investigated: simultaneously integrated boost (SIB) and WBI followed by stereotactic fractionated radiation therapy sequential concept (SC). Methods and Materials: Treatment plans for both concepts were calculated for 10 patients with 2-8 brain metastases using volumetric modulated arc therapy. In the SIB concept, the prescribed dose was 30 Gy in 12 fractions to the whole brain and 51 Gy in 12 fractions to individual brain metastases. In the SC concept, the prescription was 30 Gy in 12 fractions to the whole brain followed by 18 Gy in 2 fractions to brain metastases. All plans were optimized for dose coverage of whole brain and lesions, simultaneously minimizing dose to the hippocampus. The treatment plans were evaluated on target coverage, homogeneity, and minimal dose to the hippocampus and organs at risk. Results: The SIB concept enabled more successful sparing of the hippocampus; the mean dose to the hippocampus was 7.55 {+-} 0.62 Gy and 6.29 {+-} 0.62 Gy, respectively, when 5-mm and 10-mm avoidance regions around the hippocampus were used, normalized to 2-Gy fractions. In the SC concept, the mean dose to hippocampus was 9.8 {+-} 1.75 Gy. The mean dose to the whole brain (excluding metastases) was 33.2 {+-} 0.7 Gy and 32.7 {+-} 0.96 Gy, respectively, in the SIB concept, for 5-mm and 10-mm hippocampus avoidance regions, and 37.23 {+-} 1.42 Gy in SC. Conclusions: Both concepts, SIB and SC, were able to achieve adequate whole brain coverage and radiosurgery-equivalent dose distributions to individual brain metastases. The SIB technique achieved better sparing of the hippocampus, especially when a10-mm hippocampal avoidance region was used.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Helical Tomotherapy for Whole-Brain Irradiation With Integrated Boost to Multiple Brain Metastases: Evaluation of Dose Distribution Characteristics and Comparison With Alternative Techniques

Purpose: To quantitatively evaluate dose distribution characteristics achieved with helical tomotherapy (HT) for whole-brain irradiation (WBRT) with integrated boost (IB) to multiple brain metastases in comparison with alternative techniques. Methods and Materials: Dose distributions for 23 patients with 81 metastases treated with WBRT (30 Gy/10 fractions) and IB (50 Gy) were analyzed. The median number of metastases per patient (N{sub mets}) was 3 (range, 2-8). Mean values of the composite planning target volume of all metastases per patient (PTV{sub mets}) and of the individual metastasis planning target volume (PTV{sub ind} {sub met}) were 8.7 ± 8.9 cm{sup 3} (range, 1.3-35.5 cm{sup 3}) and 2.5 ± 4.5 cm{sup 3} (range, 0.19-24.7 cm{sup 3}), respectively. Dose distributions in PTV{sub mets} and PTV{sub ind} {sub met} were evaluated with respect to dose conformity (conformation number [CN], RTOG conformity index [PITV]), target coverage (TC), and homogeneity (homogeneity index [HI], ratio of maximum dose to prescription dose [MDPD]). The dependence of dose conformity on target size and N{sub mets} was investigated. The dose distribution characteristics were benchmarked against alternative irradiation techniques identified in a systematic literature review. Results: Mean ± standard deviation of dose distribution characteristics derived for PTV{sub mets} amounted to CN = 0.790 ± 0.101, PITV = 1.161 ± 0.154, TC = 0.95 ± 0.01, HI = 0.142 ± 0.022, and MDPD = 1.147 ± 0.029, respectively, demonstrating high dose conformity with acceptable homogeneity. Corresponding numbers for PTV{sub ind} {sub met} were CN = 0.708 ± 0.128, PITV = 1.174 ± 0.237, TC = 0.90 ± 0.10, HI = 0.140 ± 0.027, and MDPD = 1.129 ± 0.030, respectively. The target size had a statistically significant influence on dose conformity to PTV{sub mets} (CN = 0.737 for PTV{sub mets} ≤4.32 cm{sup 3} vs CN = 0.848 for PTV{sub mets} >4.32 cm{sup 3}, P=.006), in contrast to N{sub mets}. The achieved dose conformity to PTV{sub mets}, assessed by both CN and PITV, was in all investigated volume strata well within the best quartile of the values reported for alternative irradiation techniques. Conclusions: HT is a well-suited technique to deliver WBRT with IB to multiple brain metastases, yielding high-quality dose distributions. A multi-institutional prospective randomized phase 2 clinical trial to exploit efficacy and safety of the treatment concept is currently under way.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Epstein-Barr virus gH/gL has multiple sites of vulnerability for virus neutralization and fusion inhibition

Epstein-Barr virus (EBV) is nearly ubiquitous in adults. EBV causes infectious mononucleosis and is associated with B cell lymphomas, epithelial cell malignancies, and multiple sclerosis. The EBV gH/gL glycoprotein complex facilitates fusion of virus membrane with host cells and is a target of neutralizing antibodies. Here, in this study, we examined the sites of vulnerability for virus neutralization and fusion inhibition within EBV gH/gL. We developed a panel of human monoclonal antibodies (mAbs) that targeted five distinct antigenic sites on EBV gH/gL and prevented infection of epithelial and B cells. Structural analyses using X-ray crystallography and electron microscopy revealed multiple sites of vulnerability and defined the antigenic landscape of EBV gH/gL. One mAb provided near-complete protection against viremia and lymphoma in a humanized mouse EBV challenge model. Our findings provide structural and antigenic knowledge of the viral fusion machinery, yield a potential therapeutic antibody to prevent EBV disease, and emphasize gH/gL as a target for herpesvirus vaccines and therapeutics.

60 APPLIED LIFE SCIENCES↗

Biophysical analysis of the plant-specific GIPC sphingolipids reveals multiple modes of membrane regulation

The plant plasma membrane (PM) is an essential barrier between the cell and the external environment, controlling signal perception and transmission. It consists of an asymmetrical lipid bilayer made up of three different lipid classes: sphingolipids, sterols, and phospholipids. The glycosyl inositol phosphoryl ceramides (GIPCs), representing up to 40% of total sphingolipids, are assumed to be almost exclusively in the outer leaflet of the PM. However, their biological role and properties are poorly defined. In this study, we investigated the role of GIPCs in membrane organization. Because GIPCs are not commercially available, we developed a protocol to extract and isolate GIPC-enriched fractions from eudicots (cauliflower and tobacco) and monocots (leek and rice). Lipidomic analysis confirmed the presence of trihydroxylated long chain bases and 2-hydroxylated very long-chain fatty acids up to 26 carbon atoms. The glycan head groups of the GIPCs from monocots and dicots were analyzed by gas chromatograph-mass spectrometry, revealing different sugar moieties. Multiple biophysics tools, namely Langmuir monolayer, ζ-Potential, light scattering, neutron reflectivity, solid state 2H-NMR, and molecular modeling, were used to investigate the physical properties of the GIPCs, as well as their interaction with free and conjugated phytosterols. We showed that GIPCs increase the thickness and electronegativity of model membranes, interact differentially with the different phytosterols species, and regulate the gel-to-fluid phase transition during temperature variations. These results unveil the multiple roles played by GIPCs in the plant PM.

59 BASIC BIOLOGICAL SCIENCES↗

EPIsembleVis: A geo-visual analysis and comparison of the prediction ensembles of multiple COVID-19 models

In this work, we present EPIsembleVis, a web-based comparative visual analysis tool for evaluating the consistency of multiple COVID-19 prediction models. Our approach analyzes a collection of COVID-19 predictions from different epidemiological models as an ensemble and utilizes two metrics to quantify model performance. These metrics include (a) prediction uncertainty (represented as the dispersion of predictions in each ensemble) and (b) prediction error (calculated by comparing individual model predictions with the recorded data). Through an interactive visual interface, our approach provides a data-driven workflow for (a) selecting and constructing the COVID-19 model prediction ensemble based on the spatiotemporal overlap of available predictions of multiple epidemiological models, (b) quantifying the model performance using both the uncertainty of each model prediction ensemble, and the error of each ensemble member that represents individual model predictions, and (c) visualizing the spatiotemporal variability in the projection performance of individual models using a suite of novel ensemble visualization techniques, such as the data availability map, a spatiotemporal textured-tile calendar, multivariate rose chart, and time-series leaflet glyph. We demonstrate the capability of our ensemble visual interface through a case study that investigates the performance of weekly COVID-19 predictions, which are provided through the COVID-19 Forecast Hub UMass-Amherst Influenza Forecasting Center of Excellence [47] for the United States and United States Territories. The EPIsembleVis tool is implemented using open-source web technologies and adaptive system design, rendering it interoperable with Elasticsearch and Kibana for automatically ingesting COVID-19 predictions from online repositories, and it is generalizable for analyzing worldwide projections from more epidemiological models.

60 APPLIED LIFE SCIENCES↗