Search NASA⌕ Search

SEARCH · Search NASA

Results for “Microscope and microscopy.”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,189 records · Page 66

Low drift type N thermocouples in out-of-pile advanced gas reactor mock-up test: metallurgical analysis

Thermocouples are the most commonly used sensors for temperature measurement in nuclear reactors. They are crucial for the control of current nuclear reactors and for the development of GEN IV reactors. In nuclear applications thermocouples are strongly affected by intense neutron fluxes. As a result of the interaction with neutrons, the thermoelements of the thermocouples undergo transmutation, which produces a time dependent change in composition and, as a consequence, a time dependent drift of the thermocouple signal. Thermocouple drift can be very significant for in-pile temperature measurements and may render the temperature sensors unreliable after exposure to nuclear radiation for relatively short times compared to the life required for temperature sensors in nuclear applications. Previous experiences with type K thermocouples in nuclear reactors have shown that they are affected by neutron irradiation only to a limited extent. Similarly type N thermocouples are expected to be only slightly affected by neutron fluxes. Currently the use of Nickel based thermocouples is limited to temperatures lower than 1000 deg. C due to drift related to phenomena other than nuclear irradiation. As part of a collaboration between Idaho National Laboratory (INL) and the University of Cambridge a variety of Type N thermocouples have been exposed at INL in an Advanced Gas Reactor mock-up test at 1150 deg. C for 2000 h, 1200 deg. C for 2000 h, 125 deg. C for 200 h and 1300 deg. C for 200 h, and later analysed metallurgically at the University of Cambridge. The use of electron microscopy allows to identify the metallurgical changes occurring in the thermocouples during high temperature exposure and correlate the time dependent thermocouple drift with the microscopic changes experienced by the thermoelements of different thermocouple designs. In this paper conventional Inconel 600 sheathed type N thermocouples and a type N using a customized sheath developed at the University of Cambridge have been investigated. The rationale for the superior performance of the type N using a customized sheath developed at the University of Cambridge is explained in comparison with the behavior of conventional type N Inconel 600 sheathed thermocouples. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Scanning electrochemical probe microscopy investigation of two-dimensional materials

Research interests in two-dimensional (2D) materials have seen exponential growth owing to their unique and fascinating properties. The highly exposed lattice planes coupled with tunable electronic states of 2D materials have created manifold opportunities in the design of new platforms for energy conversion and sensing applications. Still, challenges in understanding the electrochemical (EC) characteristics of these materials arise from the complexity of both intrinsic and extrinsic heterogeneities that can obscure structure–activity correlations. Scanning EC probe microscopic investigations offer unique benefits in disclosing local EC reactivities at the nanoscale level that are otherwise inaccessible with macroscale methods. This review summarizes recent progress in applying techniques of scanning EC microscopy (SECM) and scanning EC cell microscopy (SECCM) to obtain distinctive insights into the fundamentals of 2D electrodes. We showcase the capabilities of EC microscopies in addressing the roles of defects, thickness, environments, strain, phase, stacking, and many other aspects in the heterogeneous electron transfer, ion transport, electrocatalysis, and photoelectrochemistry of representative 2D materials and their derivatives. Perspectives for the advantages, challenges, and future opportunities of scanning EC probe microscopy investigation of 2D structures are discussed.

36 MATERIALS SCIENCE↗

Electron microscopy study of Ni induced crystallization in amorphous Si thin films

The crystallization of amorphous silicon is studied by transmission electron microscopy. The effect of Ni on the crystallization is studied in a wide temperature range heating thinned samples in-situ inside the microscope. Two cases of limited Ni source and unlimited Ni source are studied and compared. NiSi{sub 2} phase started to form at a temperature as low as 250°C in the limited Ni source case. In-situ observation gives a clear view on the crystallization of silicon through small NiSi{sub 2} grain formation. The same phase is observed at the crystallization front in the unlimited Ni source case, where a second region is also observed with large grains of Ni{sub 3}Si{sub 2}. Low temperature experiments show, that long annealing of amorphous silicon at 410 °C already results in large crystallized Si regions due to the Ni induced crystallization.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

In vitro chick pre-cardiac explant tissue differentiation during spaceflight on SpaceHab-02

Chick precardiac tissue explants were cultured on the 8-day mission of STS-60, space shuttle Discovery. Development of in vitro cultures of precardiac chick tissue from embryo stages 5 though 8 (H-H) were initiated during orbit and were terminated after approximately fifteen hours of 37 degree C culture. Transmission electron microscopy and tritiated thymidine studies were performed postflight. No significant differences in cell proliferation were observed between flight and ground controls. Electron-microscopic studies revealed stage 8 explants were capable of differentiation during flight in a pattern which matched ground control tissues. As anticipated, stage 7 explant tissues had differentiated to a lesser extent compared to stage 8 tissues. Interestingly, stage 7 precardiac explant flight tissue differentiation was less than ground control tissue. This difference in differentiation between flight and ground cultures was enhanced in stage 6 tissues, as high levels of myofibril organization were only seen in ground controls. Other cellular components such as Golgi apparatus, junctional complexes, and mitochondria were present and appeared normal and healthy.

NASA Program NSCORT↗

Shock Initiation Microscopy with High Time and Space Resolution

In this paper, we describe studies of shock initiation and shock-to-detonation transitions in energetic materials using a tabletop shock compression microscope with nanosecond time resolution and micrometer spatial resolution. Planar input shocks with durations of 4–20 ns are produced using 0–4.5 km/s laser-launched flyer plates. Emphasis is on measurements of temperature, velocities, pressure, and microstructure using photon Doppler velocimetry (PDV), optical pyrometry and high-speed videography. Techniques are discussed for fabricating disposable shock target arrays of tiny plastic-bonded explosives (PBX), liquid and powder explosives, and single-crystal explosives for high-throughput studies. Optical temperature measurements of shocked triaminotrinitrobenzene (TATB) are discussed. Since TATB is yellow, we developed methods to correct for the blue absorption to obtain more accurate temperatures. Hot spots in shocked polymer-encased HMX (octahydro-1,3,5,7-tetranitro-1,3,5,7-tetrazocine) crystals are observed in real-time, showing a hot spot produced in a collapsing void that ignites a deflagration. Despite the small dimensions of our explosive charges (typically 1 mm diameter and 250 μm length), we produced reproducible detonation states in solid and liquid explosives using short-duration shocks near the von Neumann spike (VNS) pressure. We show the VNS pressure is associated with a transition to high-efficiency gas production from the explosives. In studies of NM, prior to detonation, we see reaction originating at hot spots which coalesce to form a superdetonation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Origin of organic matter and organic pores in the overmature Ordovician-Silurian Wufeng-Longmaxi Shale of the Sichuan Basin, China

Organic matter (OM)-hosted pores play important roles in controlling the porosity and gas content of gas shales. However, the control of organic pore development and preservation remains poorly understood, partly because of the inability to distinguish OM types under the scanning electron microscope (SEM). In this study, seven over-mature Wufeng-Longmaxi Shale samples (equivalent vitrinite reflectance 1.93%–3.07%) were investigated with organic petrography and scanning electron microscope to study the origin of OM and development of organic pores in this black shale succession. Correlative light and electron microscopy was employed to examine pore development in individual macerals. Organic petrographic observations show that OM in these over-mature black shales is dominated by pyrobitumen and graptolites (> 90 vol.% of total OM based on point counting). Pyrobitumen mainly occurs as matrix bitumen in the fine-grained matrix, and also as a mixture with clay minerals and fossil cavity infillings. Vitrinite-like particles are minor constituents of OM in the Wufeng-Longmaxi Shale, and their average reflectance, reflectance distribution, and morphology suggest that they may be derived from graptolite fragments lacking diagnostic features and acritarchs. OM type critically controls the development of organic pores. Here, organic pores primarily occur in pyrobitumen, whereas other macerals are mostly non-porous when examined under the SEM. Results of this study provided important insights into OM thermal evolution and organic pore development in source-rock reservoirs, calling for a critical appraisal of OM in black shales with organic petrography in addition to SEM.

03 NATURAL GAS↗

Analytical Formulae for Calculation of X-Ray Detector Solid Angles in the Scanning and Scanning/Transmission Analytical Electron Microscope

Closed form analytical equations used to calculate the collection solid angle of six common geometries of solid-state X-ray detectors in scanning and scanning/transmission analytical electron microscopy are presented. Using these formulae one can make realistic comparisons of the merits of the different detector geometries in modern electron column instruments. This work updates earlier formulations and adds new detector configurations.

Zaluzec, Nestor J.↗

Phase Imaging: A Compressive Sensing Approach

Since Wolfgang Pauli posed the question in 1933, whether the probability densities |Ψ(r)|² (real-space image) and |Ψ(q)|² (reciprocal space image) uniquely determine the wave function Ψ(r) [1], the so called Pauli Problem sparked numerous methods in all fields of microscopy [2, 3]. Reconstructing the complete wave function Ψ(r) = a(r)e-iφ(r) with the amplitude a(r) and the phase φ(r) from the recorded intensity enables the possibility to directly study the electric and magnetic properties of the sample through the phase. In transmission electron microscopy (TEM), electron holography is by far the most established method for phase reconstruction [4]. Requiring a high stability of the microscope, next to the installation of a biprism in the TEM, holography cannot be applied to any microscope straightforwardly. Recently, a phase retrieval approach was proposed using conventional TEM electron diffractive imaging (EDI). Using the SAD aperture as reciprocal-space constraint, a localized sample structure can be reconstructed from its diffraction pattern and a real-space image using the hybrid input-output algorithm [5]. We present an alternative approach using compressive phase-retrieval [6]. Our approach does not require a real-space image. Instead, random complimentary pairs of checkerboard masks are cut into a 200 nm Pt foil covering a conventional TEM aperture (cf. Figure 1). Used as SAD aperture, subsequently diffraction patterns are recorded from the same sample area. Hereby every mask blocks different parts of gold particles on a carbon support (cf. Figure 2). The compressive sensing problem has the following formulation. First, we note that the complex-valued reciprocal-space wave-function is the Fourier transform of the (also complex-valued) real-space wave-function, Ψ(q) = F[Ψ(r)], and subsequently the diffraction pattern image is given by |Ψ(q)|2 = |F[Ψ(r)]|2. We want to find Ψ(r) given a few differently coded diffraction pattern measurements yn = |F[HnΨ(r)]|2, where the matrices Hn encode the mask structure of the aperture. This is a nonlinear inverse problem, but has been shown to be solvable even in the underdetermined case [6]. Since each diffraction pattern yn contains diffraction information from selected regions of the same sample, the differences in each pattern contain local phase information, which can be combined to form a full estimate of the real-space wave-function[7]. References: [1] W. Pauli in “Die allgemeinen Prinzipien der Wellenmechanik“, ed. H Geiger and W Scheel, (Julius Springer, Berlin). [2] A. Tonomura, Rev. Mod. Phys. 59 (1987), p. 639. [3] J. Miao et al, Nature 400 (1999), p. 342. [4] H. Lichte et al, Annu. Rev. Mater. Res. 37 (2007), p. 539. [5] J. Yamasaki et al, Appl. Phys. Lett. 101 (2012), 234105. [6] P Schniter and S Rangan. Signal Proc., IEEE Trans. on. 64(4), (2015), pp. 1043. [7] Supported by the Chemical Imaging, Signature Discovery, and Analytics in Motion initiatives at PNNL. PNNL is operated by Battelle Memorial Inst. for the US DOE; contract DE-AC05-76RL01830.

Schneider, Sebastian↗

Carbon Monoxide Mediated Hydrogen Release from PtCu Single-Atom Alloys: The Punctured Molecular Cork Effect

Pt-based materials are used extensively in heterogeneous catalytic processes, yet they are notoriously susceptible to poisoning by CO. In contrast, highly dilute binary alloys formed of isolated Pt atoms in a Cu metal host, known as PtCu single-atom alloys (SAAs), are more resilient to CO poisoning during catalytic hydrogenation reactions. In this article, we describe how CO affects the adsorption and desorption of H 2 from a model PtCu(111) SAA surface and gain a microscopic understanding of these species’ interaction at the Pt atom active sites. By combining temperature-programmed desorption and scanning tunneling microscopy with first-principles kinetic Monte Carlo, we identify CO as a Pt site blocker that prevents the low temperature adsorption and desorption of H 2 , the so-called molecular cork effect , first realized when examining PdCu SAAs. Intriguingly, for the case of PtCu, H 2 desorption occurs before CO release is detected. Additionally, desorption experiments show a nonlinear relationship between CO coverage of the Pt sites and H 2 desorption peak temperature. When all the Pt atoms are saturated by CO, a very sharp H 2 desorption feature is observed 55 K above the regular desorption temperature of H 2 . Our simulations reveal that the origin of these effects is the fact that desorption of just one CO molecule from a Pt site facilitates the fast release of many molecules of H 2 . In fact, just 0.7% of the CO adsorbed at Pt sites has desorbed when the H 2 desorption peak maximum is reached. The release of H 2 from CO-corked PtCu SAA surfaces is analogous to the escape of gas from a pressurized container with a small puncture. Given that small changes in CO surface coverage lead to large changes in H 2 evolution energetics, the punctured molecular cork effect must be considered when modeling reaction mechanisms on similar alloy systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Supercontinuum Stimulated Emission Depletion Fluorescence Lifetime Imaging

Supercontinuum (SC) stimulated emission depletion (STED) fluorescence lifetime imaging is demonstrated by using time-correlated single-photon counting (TCSPC) detection. The spatial resolution of the developed STED instrument was measured by imaging monodispersed 40-nm fluorescent beads and then determining their fwhm, and was 36 ± 9 and 40 ± 10 nm in the X and Y coordinates, respectively. The same beads measured by confocal microscopy were 450 ± 50 and 430 ± 30 nm, which is larger than the diffraction limit of light due to underfilling the microscope objective. Underfilling the objective and time gating the signal were necessary to achieve the stated STED spatial resolution. The same fluorescence lifetime (2.0 ± 0.1 ns) was measured for the fluorescent beads by using confocal or STED lifetime imaging. The instrument has been applied to study Alexa Fluor 594-phalloidin labeled F-actin-rich projections with dimensions smaller than the diffraction limit of light in cultured cells. Fluorescence lifetimes of the actin-rich projections range from 2.2 to 2.9 ns as measured by STED lifetime imaging.

36 MATERIALS SCIENCE↗

Investigation of static and dynamic behavior of functionally graded piezoelectric actuated Poly-Si micro cantilever probe

In the present paper a novel functionally graded piezoelectric (FGP) actuated Poly-Si micro cantilever probe is proposed for atomic force microscope. The shear piezoelectric coefficient d{sub 15} has much higher value than coupling coefficients d{sub 31} and d{sub 33}, hence in the present work the micro cantilever beam actuated by d{sub 15} effect is utilized. The material properties are graded in the thickness direction of actuator by a simple power law. A three dimensional finite element analysis has been performed using COMSOL Multiphysics® (version 4.2) software. Tip deflection and free vibration analysis for the micro cantilever probe has been done. The results presented in the paper shall be useful in the design of micro cantilever probe and their subsequent utilization in atomic force microscopes.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Superconductivity in Nb-Sn Thin Films of Stoichiometric and Off-Stoichiometric Compositions

Binary Nb-Sn thin film samples were fabricated and characterized in terms of their composition, morphology, and superconducting properties. Nb-Sn was magnetron-sputtered onto heated R-plane sapphire substrates at 700 °C, 800 °C, and 900 °C, using a custom-built heater assembly. Samples were cut into strips, where each strip has a unique composition. For a subset of the samples, Nb-Sn was selectively etched away at an etching rate of 6 ± 1 nm/s using an aqueous solution of 3 vol. % hydrofluoric and 19 vol. % nitric acid. The sample composition was investigated with a scanning electron microscope with an X-ray energy dispersive spectroscopy detector. Surface and cross-section morphologies were investigated using scanning electron microscopy and scanning transmission electron microscopy, revealing a dense columnar poly-crystalline grain structure. X-ray diffraction measurements indicate a highly textured film that is (100) oriented out-of-plane and random in-plane. The critical temperature Tc (ranging from 9.8 to 17.9 K), critical magnetic field μ-0 H c2 (ranging from 12.5 to 31.3 T), residual resistivity ratio (RRR), and normal state resistivity ρ 0 were measured and found to be broadly consistent with literature data on bulk Nb- 3 Sn.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Microstructural Study of Hydration of C 3 S in the Presence of Calcium Nitrate Using Scanning Transmission X-Ray Microscopy (STXM)

Calcium nitrate (CN) is used widely as an effectively inorganic setting accelerator and antifreeze admixture in concrete structures. In this paper, the multiscale investigation of CN on the hydration of C 3 S was studied by scanning transmission X-ray microscopy (STXM) combined with near-edge X-ray absorption fine structure (NEXAFS), 29 Si MAS NMR, calorimetry, scanning electron microscope, and N 2 absorption. It was concluded that the calcium silicate hydrate (C-S-H) surrounds the unhydrated C 3 S at 1-day hydrated C 3 S in the presence of calcium nitrate, while portlandite is partly in transformation and is formed partly. Based on Ca L 3 , 2 -edge NEXAFS spectra for 1-day hydrated C 3 S particle, calcium nitrate does not change the structure of the asymmetrically 7-fold coordination of calcium in the C-S-H. Calcium nitrate can accelerate the hydration of C 3 S to some extent and polymerization of the silicate chains within C-S-H considerably at early age, resulting in the increasing specific surface area.

Li, Qinfei↗

Multimodal Few-Shot Segmentation of Electron Micrographs

Scanning transmission electron microscopy (STEM) is one of the most used methods of analyzing the chemistry and composition of materials. By analyzing microstructures, these microscopes can help scientists better understand the molecular underpinnings of microelectronics, batteries, and more. However, STEM data can be difficult to interpret, so recent developments have been made in applications of machine learning to analyze these images. The PNNL-developed pyCHIP Classifier has achieved results in segmenting STEM these images via few-shot learning, a method which requires little data and human input, perfect for quickly analysis. In my internship I (Eli Meyers) investigated a multimodal improvement of this classifier by incorporating energy dispersive x-ray spectroscopy (EDS) data into the classification process for a more accurate segmentation. Furthermore, I encoded the spectral data by training a mass spectrometry encoder on the EDS data to extract a more meaningful representation of the data.

36 MATERIALS SCIENCE↗

Recent Advances in Soft Matter Characterization Capabilities Developed at NASA GRC for Lunar Exploration: Differential Dynamic Microscopy to Spectroscopy to Computer Vision

In 1991, famous French scientist Pierre-Gilles de Genes was awarded Nobel prize for his impactful research in soft matter, more specifically polymers. He is defined as the founding father of soft matter. In his Nobel lecture (https://www.nobelprize.org/uploads/2018/06/gennes-lecture.pdf ) he described soft matter aka complex fluids as materials with two primary features – (a) complexity and (b) flexibility. The sub-categories of soft matter (e.g.- granular materials, polymers, foams, colloids etc.) are defined on the basis of Pierre-Gilles de Gennes’ definition. At NASA GRC, we are pushing the boundaries for fundamental study of soft matter on Lunar Surface. With regard to Lunar surface science, we are focusing on developing capabilities pertaining to granular materials and bio-soft/active matter to facilitate future efforts in ISRU and bio-ISRU capabilities. In order to achieve fundamental goals of soft matter research within the limitations of Lunar environment, the scientific capabilities need to be small, flexible, modular, off the shelf and the focus needs to be more on developing an interdisciplinary capability that leverages the recent growth in AI/ML and Computer Vision to augment our understanding of fundamental science. This strategy would allow us to reduce our resource requirement during launch, installation, and occupied real estate footprint on Lunar surface In this talk, we will go over 3 different capabilities that we have developed in house and in close collaboration – (a) Differential Dynamic Microscopy (DDM), (b) Portable In-situ Chemical Spectroscopy (PICS) and (c) Computer Vision Enabled Observation. At very high level, Differential Dynamic Microscopy (DDM) allows us to study the structure-property-process relation (microrheology) of bio-soft/active matter using optical microscope and improved image analysis capabilities. PICS uses AI/ML-based advanced signal deconvolution and analysis technique that can work with existing portable spectroscopy tools to perform materials analysis (e.g.- granular materials and bio-soft/active matter) inspection on the go. Finally, computer vision enabled analysis allows us to use simple camera images for 3D reconstruction of experimental process and tracking of objects of interest in an experiment. We expect that this detailed process will allow us reach a thorough understanding of soft matter in Lunar environment. The capabilities developed by us will help to validate and establish fundamental understanding in Lunar environment. This will, in turn, allow us to guide future space exploration missions and expand the knowledge base of the scientific and engineering communities.

Suman Sinha Ray↗

Recent Advances in Soft Matter Characterization Capabilities Developed at NASA GRC for Lunar Exploration: Differential Dynamic Microscopy to Spectroscopy to Computer Vision

In 1991, famous French scientist Pierre-Gilles de Genes was awarded Nobel prize for his impactful research in soft matter, more specifically polymers. He is defined as the founding father of soft matter. In his Nobel lecture (https://www.nobelprize.org/uploads/2018/06/gennes-lecture.pdf ) he described soft matter aka complex fluids as materials with two primary features – (a) complexity and (b) flexibility. The sub-categories of soft matter (e.g.- granular materials, polymers, foams, colloids etc.) are defined on the basis of Pierre-Gilles de Gennes’ definition. At NASA GRC, we are pushing the boundaries for fundamental study of soft matter on Lunar Surface. With regard to Lunar surface science, we are focusing on developing capabilities pertaining to granular materials and bio-soft/active matter to facilitate future efforts in ISRU and bio-ISRU capabilities. In order to achieve fundamental goals of soft matter research within the limitations of Lunar environment, the scientific capabilities need to be small, flexible, modular, off the shelf and the focus needs to be more on developing an interdisciplinary capability that leverages the recent growth in AI/ML and Computer Vision to augment our understanding of fundamental science. This strategy would allow us to reduce our resource requirement during launch, installation, and occupied real estate footprint on Lunar surface. In this talk, we will go over 3 different capabilities that we have developed in house and in close collaboration – (a) Differential Dynamic Microscopy (DDM), (b) Portable In-situ Chemical Spectroscopy (PICS) and (c) Computer Vision Enabled Observation. At very high level, Differential Dynamic Microscopy (DDM) allows us to study the structure-property-process relation (microrheology) of bio-soft/active matter using optical microscope and improved image analysis capabilities. PICS uses AI/ML-based advanced signal deconvolution and analysis technique that can work with existing portable spectroscopy tools to perform materials analysis (e.g.- granular materials and bio-soft/active matter) inspection on the go. Finally, computer vision enabled analysis allows us to use simple camera images for 3D reconstruction of experimental process and tracking of objects of interest in an experiment. We expect that this detailed process will allow us reach a thorough understanding of soft matter in Lunar environment. The capabilities developed by us will help to validate and establish fundamental understanding in Lunar environment. This will, in turn, allow us to guide future space exploration missions and expand the knowledge base of the scientific and engineering communities.

Suman Sinha-Ray↗

Recent Advances in Soft Matter Characterization Capabilities Developed at NASA GRC for Lunar Exploration: Differential Dynamic Microscopy to Spectroscopy to Computer Vision

In 1991, famous French scientist Pierre-Gilles de Genes was awarded Nobel prize for his impactful research in soft matter, more specifically polymers. He is defined as the founding father of soft matter. In his Nobel lecture (https://www.nobelprize.org/uploads/2018/06/gennes-lecture.pdf ) he described soft matter aka complex fluids as materials with two primary features – (a) complexity and (b) flexibility. The sub-categories of soft matter (e.g.- granular materials, polymers, foams, colloids etc.) are defined on the basis of Pierre-Gilles de Gennes’ definition. At NASA GRC, we are pushing the boundaries for fundamental study of soft matter on Lunar Surface. With regard to Lunar surface science, we are focusing on developing capabilities pertaining to granular materials and bio-soft/active matter to facilitate future efforts in ISRU and bio-ISRU capabilities. In order to achieve fundamental goals of soft matter research within the limitations of Lunar environment, the scientific capabilities need to be small, flexible, modular, off the shelf and the focus needs to be more on developing an interdisciplinary capability that leverages the recent growth in AI/ML and Computer Vision to augment our understanding of fundamental science. This strategy would allow us to reduce our resource requirement during launch, installation, and occupied real estate footprint on Lunar surface In this talk, we will go over 3 different capabilities that we have developed in house and in close collaboration – (a) Differential Dynamic Microscopy (DDM), (b) Portable In-situ Chemical Spectroscopy (PICS) and (c) Computer Vision Enabled Observation. At very high level, Differential Dynamic Microscopy (DDM) allows us to study the structure-property-process relation (microrheology) of bio-soft/active matter using optical microscope and improved image analysis capabilities. PICS uses AI/ML-based advanced signal deconvolution and analysis technique that can work with existing portable spectroscopy tools to perform materials analysis (e.g.- granular materials and bio-soft/active matter) inspection on the go. Finally, computer vision enabled analysis allows us to use simple camera images for 3D reconstruction of experimental process and tracking of objects of interest in an experiment. We expect that this detailed process will allow us reach a thorough understanding of soft matter in Lunar environment. The capabilities developed by us will help to validate and establish fundamental understanding in Lunar environment. This will, in turn, allow us to guide future space exploration missions and expand the knowledge base of the scientific and engineering communities.

Suman Sinha Ray↗