Search NASA⌕ Search

SEARCH · Search NASA

Results for “Monitor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,189 records · Page 66

Automated Framework for Groundwater Monitoring Using DWT with LSTM and Transformers

Environmental monitoring is critical for safeguarding public health and ecological well-being. Traditional data structuring and workflow monitoring methods consume significant time and effort, hindering timely insights and effective decision-making. Our study addresses this challenge by presenting an AI framework that automates data cleaning, structuring, and modeling processes, specifically targeting applications in groundwater monitoring. By leveraging automation for data processing and model training, our framework establishes a novel and efficient paradigm for environmental monitoring, with its potential application to the vast network of over a hundred Department of Energy Environmental Management (DoE-EM) cleanup sites across the country. It analyzes data streams from a network of groundwater Internet-of-Things (IoT) sensors deployed at the Savannah River Site (SRS) for prediction modeling. This allows human experts to focus on analysis and decision-making, ultimately leading to better environmental outcomes.The framework employs multivariate time-series forecasting methods to study and model the behavior of varying chemical analytes. The continuous learning process is enabled by utilizing deep learning techniques. It allows the framework to become more nuanced in its analysis over time, adapting to the specific characteristics of the environmental site and the evolving nature of contaminant behavior. Deep learning models known for sequence modeling, LSTM, and Transformers are employed for time series forecasting. Data processing and structuring are essential components significantly impacting the final model's performance. This hypothesis was proven by presenting a comparative analysis of model performance with processed and unprocessed data. The feature engineering approach utilized was the Discrete Wavelet Transform, which works well with time series data.

Discrete Wavelet Transform (DWT)↗

Developing Effective Continuous On-Line Monitoring Technologies to Manage Service Degradation of Nuclear Power Plants

Recently, there has been increased interest in using prognostics (i.e, remaining useful life (RUL) prediction) for managing and mitigating aging effects in service-degraded passive nuclear power reactor components. A vital part of this philosophy is the development of tools for detecting and monitoring service-induced degradation. Experience with in-service degradation has shown that rapidly-growing cracks, including several varieties of stress corrosion cracks (SCCs), can grow through a pipe in less than one fuel outage cycle after they initiate. Periodic inspection has limited effectiveness at detecting and managing such degradation requiring a more versatile monitoring philosophy. Acoustic emission testing (AET) and guided wave ultrasonic testing (GUT) are related technologies with potential for on-line monitoring applications. However, harsh operating conditions within NPPs inhibit the widespread implementation of both technologies. For AET, another hurdle is the attenuation of passive degradation signals as they travel though large components, relegating AET to targeted applications. GUT is further hindered by the complexity of GUT signatures limiting its application to the inspection of simple components. The development of sensors that are robust and inexpensive is key to expanding the use of AET and GUT for degradation monitoring in NPPs and improving overall effectiveness. Meanwhile, the effectiveness of AET and GUT in NPPs can be enhanced through thoughtful application of tandem AET-GUT techniques.

acoustic emission↗

Connect the Dots: In Situ 4-D Seismic Monitoring of CO 2 Storage With Spatio-Temporal CNNs

4-D seismic imaging has been widely used in CO 2 sequestration projects to monitor the fluid flow in the volumetric subsurface region that is not sampled by wells. Ideally, real-time monitoring and near-future forecasting would provide site operators with great insights to understand the dynamics of the subsurface reservoir and assess any potential risks. However, due to obstacles such as high deployment cost, availability of acquisition equipment, exclusion zones around surface structures, only very sparse seismic imaging data can be obtained during monitoring. That leads to an unavoidable and growing knowledge gap over time. The operator needs to understand the fluid flow throughout the project lifetime and the seismic data are only available at a limited number of times. This is insufficient for understanding reservoir behavior. To overcome those challenges, we have developed spatio-temporal neural-network-based models that can produce high-fidelity interpolated or extrapolated images effectively and efficiently. Specifically, our models are built on an autoencoder, and incorporate the long short-term memory (LSTM) structure with a new loss function regularized by optical flow. We validate the performance of our models using real 4-D post-stack seismic imaging data acquired at the Sleipner CO 2 sequestration field. We employ two different strategies in evaluating our models. Numerically, we compare our models with different baseline approaches using classic pixel-based metrics. We also conduct a blind survey and collect a total of 20 responses from domain experts to evaluate the quality of data generated by our models. Finally, via both numerical and expert evaluation, we conclude that our models can produce high-quality 2-D/3-D seismic imaging data at a reasonable cost, offering the possibility of real-time monitoring or even near-future forecasting of the CO 2 storage reservoir.

4-D seismic imaging↗

Smart Meters Enabling Voltage Monitoring and Control Functionalities: The Last-Mile Voltage Stability Issue

It is a demanding yet challenging task to design the next generation of smart meters. This work investigates the new voltage monitoring and control function for the next-generation smart meters, and identifies its added values for power system voltage stability issues. In terms of voltage monitoring, the risk benefit analysis for adding voltage magnitudes to smart meter measurements is presented, and the risk mitigation strategies along with the co-simulation validation via GridLAB-D and NS-3 are proposed, all providing insight into the new function evaluation. In terms of voltage control, a new voltage stability control scheme is developed, which uses voltage measurements from smart meters and utilizes the observability and controllability of distributed energy resources and controllable loads. Different from traditional voltage control schemes focusing on voltage regulation and power quality monitoring from the utility perspective, the proposed control scheme can achieve the maximum real power transfer margin at the end user side, enabling the voltage stability issues being solved at the grid edge, i.e. the last-mile segment. It is the first work that considers voltage monitoring and control collectively for smart meter investment. It can help power engineering community supplement smart meter applications and shape the next-generation smart meters.

42 ENGINEERING↗

Deep Neural Network Assisted Distributed Strain and Temperature Fiber Sensor System for Natural Gas Pipeline Monitoring

Natural gas pipeline integrity monitoring is crucial to detect potential leaks, find structural issues, and prevent environmental damage. This article presents a system of natural gas pipeline monitoring that uses a specialized double Brillouin peak sensing fiber along with the Brillouin optical time domain analysis (BOTDAs) technique. The calibrated sensing fiber coefficients for strain and temperature are 41.8 kHz/ με and 0.9 MHz/°C for peak 1; and 47.2 kHz/ με , and 1.11 MHz/°C for peak 2, respectively. Initially, lab tests were performed by installing a short section of double Brillouin peak fiber (DBPF) on a 1-in steel pipe under pressure up to 1000 per square inch (psi) at elevated temperatures. Simultaneous distributed measurements of temperature and pressure-induced hoop strain were successfully measured. Considering the long processing speed to extract Brillouin frequency shift (BFS), we employ a novel probabilistic deep neural network (PDNN) framework for rapid BFS prediction. Additionally, using the Finite Element Method, the effects of the pipeline pressure on hoop strain were modeled and compared to the experimental hoop strain under the same set of pipeline conditions. Finally, an actual 4-in outer diameter steel natural gas pipeline was used for pilot-scale tests, where hoop strain was measured at various pressure levels. Leaks were simulated to demonstrate accurate pipeline integrity monitoring. At an internal pipe pressure of 1000 psi, hoop strain of approximately 300 με was observed, and the sensitivity was calculated as 0.28 με /psi. The results of this pilot-scale study demonstrated that the system is capable of performing distributed monitoring sufficient to detect pipeline pressure and the presence of leaks to ensure the safe operation of gas pipelines in the field.

03 NATURAL GAS↗

Low-cost embedded optical sensing systems for distribution transformer monitoring

There is a mounting need for low-cost monitoring with online sensing technologies to maintain grid reliability and uptime. Here we introduce an innovative low-cost, embedded optical sensing technology initially focused on transformers that was developed and demonstrated at a major electric utility, Con Edison. A version of it that can be retrofitted onto existing transformers in the field was also developed. Two new 500 kVA distribution network transformers were built with embedded fiber-optic (FO) sensors and qualified per industry standards. Vibration, temperature, and corrosion were key parameters monitored. The first transformer with embedded FO sensors was installed at a Con Edison facility and monitored at our team’s office. The second one was installed in an urban street-side underground location with online data processing/feature extraction algorithms and monitored through a wireless router. Additionally, an older transformer was also retrofitted. Data analysis was done on these transformers showing promising correlations with their corresponding loading cycles. Furthermore, key events such as the transformer primary-side energizing, and other events were detected. In general, the technology was demonstrated over 6 months across the 3 transformers instrumented with promising results. Thus, it has the potential to enable predictive maintenance for transformers and other grid assets.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Condition Monitoring of Wind Turbine Planetary Gearboxes Under Different Operating Conditions

Digitally enhanced services for wind power could reduce Operations and Maintenance costs as well as the Levelised Cost Of Energy. Therefore, there is a continuous need for advanced monitoring techniques which can exploit the opportunities of Internet of Things and Big Data Analytics. The heart of wind turbines is an epicyclic gearbox and rolling element bearings are often responsible for machinery stops. The vibration signatures of bearings are rather weak compared to other components. As a result a number of signal processing techniques have been proposed, focusing towards accurate and early fault detection with limited false alarms and missed detections. In Envelope Analysis an envelope of the vibration signal is estimated usually after filtering around a frequency band. Different tools, such as Kurtogram, have been proposed to select the optimum filter parameters. Monitoring techniques have reached a mature level for steady speed and load operating conditions. On the other hand, under chaniging operating conditions, it is still unclear whether the change of the monitoring indicators is due to the change of the machinery's health or due to the change of operating parameters. Recently, the authors have proposed a new tool called IESFOgram, based on Cyclic Spectral Coherence for the automatic selection of the filtering band. In this paper, the performance of the tool is evaluated on the National Renewable Energy Laboratory wind turbine gearbox vibration condition monitoring benchmarking data set which includes various faults with different levels of diagnostic complexity as well as various speed and load operating conditions.

17 WIND ENERGY↗

Remote-sensing application for facilitating land resource assessment and monitoring for utility-scale solar energy development

A monitoring plan that incorporates regional datasets and integrates cost-effective data collection methods is necessary to sustain the long-term environmental monitoring of utility-scale solar energy development in expansive, environmentally sensitive desert environments. Using very high spatial resolution (VHSR; 15 cm) multispectral imagery collected in November 2012 and January 2014, an image processing routine was developed to characterize ephemeral streams, vegetation, and land surface in the southwestern United States where increased utility-scale solar development is anticipated. In addition to knowledge about desert landscapes, the methodology integrates existing spectral indices and transformation (e.g., visible atmospherically resistant index and principal components); a newly developed index, erosion resistance index (ERI); and digital terrain and surface models, all of which were derived from a common VHSR image. The methodology identified fine-scale ephemeral streams with greater detail than the National Hydrography Dataset and accurately estimated vegetation distribution and fractional cover of various surface types. The ERI classified surface types that have a range of erosive potentials. The remote-sensing methodology could ultimately reduce uncertainty and monitoring costs for all stakeholders by providing a cost-effective monitoring approach that accurately characterizes the land resources at potential development sites.

Desert regions↗

Monitoring radiation use in cardiac fluoroscopy imaging procedures

Purpose: Timely identification of systematic changes in radiation delivery of an imaging system can lead to a reduction in risk for the patients involved. However, existing quality assurance programs involving the routine testing of equipment performance using phantoms are limited in their ability to effectively carry out this task. To address this issue, the authors propose the implementation of an ongoing monitoring process that utilizes procedural data to identify unexpected large or small radiation exposures for individual patients, as well as to detect persistent changes in the radiation output of imaging platforms. Methods: Data used in this study were obtained from records routinely collected during procedures performed in the cardiac catheterization imaging facility at St. Andrew's War Memorial Hospital, Brisbane, Australia, over the period January 2008-March 2010. A two stage monitoring process employing individual and exponentially weighted moving average (EWMA) control charts was developed and used to identify unexpectedly high or low radiation exposure levels for individual patients, as well as detect persistent changes in the radiation output delivered by the imaging systems. To increase sensitivity of the charts, we account for variation in dose area product (DAP) values due to other measured factors (patient weight, fluoroscopy time, and digital acquisition frame count) using multiple linear regression. Control charts are then constructed using the residual values from this linear regression. The proposed monitoring process was evaluated using simulation to model the performance of the process under known conditions. Results: Retrospective application of this technique to actual clinical data identified a number of cases in which the DAP result could be considered unexpected. Most of these, upon review, were attributed to data entry errors. The charts monitoring the overall system radiation output trends demonstrated changes in equipment performance associated with relocation of the equipment to a new department. When tested under simulated conditions, the EWMA chart was capable of detecting a sustained 15% increase in average radiation output within 60 cases (<1 month of operation), while a 33% increase would be signaled within 20 cases. Conclusions: This technique offers a valuable enhancement to existing quality assurance programs in radiology that rely upon the testing of equipment radiation output at discrete time frames to ensure performance security.

60 APPLIED LIFE SCIENCES↗

Management of the baseline shift using a new and simple method for respiratory-gated radiation therapy: Detectability and effectiveness of a flexible monitoring system

Purpose: In respiratory-gated radiation therapy, a baseline shift decreases the accuracy of target coverage and organs at risk (OAR) sparing. The effectiveness of audio-feedback and audio-visual feedback in correcting the baseline shift in the breathing pattern of the patient has been demonstrated previously. However, the baseline shift derived from the intrafraction motion of the patient's body cannot be corrected by these methods. In the present study, the authors designed and developed a simple and flexible system. Methods: The system consisted of a web camera and a computer running our in-house software. The in-house software was adapted to template matching and also to no preimage processing. The system was capable of monitoring the baseline shift in the intrafraction motion of the patient's body. Another marker box was used to monitor the baseline shift due to the flexible setups required of a marker box for gated signals. The system accuracy was evaluated by employing a respiratory motion phantom and was found to be within AAPM Task Group 142 tolerance (positional accuracy <2 mm and temporal accuracy <100 ms) for respiratory-gated radiation therapy. Additionally, the effectiveness of this flexible and independent system in gated treatment was investigated in healthy volunteers, in terms of the results from the differences in the baseline shift detectable between the marker positions, which the authors evaluated statistically. Results: The movement of the marker on the sternum [1.599 {+-} 0.622 mm (1 SD)] was substantially decreased as compared with the abdomen [6.547 {+-} 0.962 mm (1 SD)]. Additionally, in all of the volunteers, the baseline shifts for the sternum [-0.136 {+-} 0.868 (2 SD)] were in better agreement with the nominal baseline shifts than was the case for the abdomen [-0.722 {+-} 1.56 mm (2 SD)]. The baseline shifts could be accurately measured and detected using the monitoring system, which could acquire the movement of the marker on the sternum. The baseline shift-monitoring system with the displacement-based methods for highly accurate respiratory-gated treatments should be used to make most of the displacement-based gating methods. Conclusions: The advent of intensity modulated radiation therapy and volumetric modulated radiation therapy facilitates margin reduction for the planning target volumes and the OARs, but highly accurate irradiation is needed to achieve target coverage and OAR sparing with a small margin. The baseline shifts can affect treatment not only with the respiratory gating system but also without the system. Our system can manage the baseline shift and also enables treatment irradiation to be undertaken with high accuracy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Missile Captive Carry Monitoring and Helicopter Identification Using a Capacitive Microelectromechanical Systems Accelerometer

Military missiles are exposed to many sources of mechanical vibration that can affect system reliability, safety, and mission effectiveness. The U. S. Army Aviation and Missile Research Development and Engineering Center (AMRDEC) has been developing missile health monitoring systems to assess and improve reliability, reduce life cycle costs, and increase system readiness. One of the most significant exposures to vibration occurs when the missile is being carried by a helicopter or other aviation platform, which is a condition known as captive carry. Recording the duration of captive carry exposure during the missile’s service life can enable the implementation of predictive maintenance and resource management programs. Since the vibration imparted by each class of helicopter varies in frequency and amplitude, tracking the vibration exposure from each helicopter separately can help quantify the severity and harmonic content of the exposure. Under the direction of AMRDEC staff, engineers at the Pacific Northwest National Laboratory have developed a Captive Carry Health Monitor (CCHM) for the Hellfire II missile. The CCHM is an embedded usage monitoring device installed on the outer skin of the Hellfire II missile to record the cumulative hours the host missile has been in captive carry mode. To classify the vibration by class of helicopter, the CCHM analyzes the amplitude and frequency content of the vibration with the Goertzel algorithm to detect the presence of distinctive rotor harmonics. Cumulative usage data are accessible in theater from an external display; monthly usage histograms are accessible through an internal download connector. This paper provides an overview of the CCHM electrical and package design, describes field testing and data analysis techniques used to monitor captive carry identify and the class of helicopter, and discusses the potential application of missile health and usage data for real-time reliability analysis and fleet management.

Goertzel, HUMS↗

On the vulnerability of data-driven structural health monitoring models to adversarial attack

Many approaches at the forefront of structural health monitoring rely on cutting-edge techniques from the field of machine learning. Recently, much interest has been directed towards the study of so-called adversarial examples; deliberate input perturbations that deceive machine learning models while remaining semantically identical. This article demonstrates that data-driven approaches to structural health monitoring are vulnerable to attacks of this kind. In the perfect information or ‘white-box’ scenario, a transformation is found that maps every example in the Los Alamos National Laboratory three-storey structure dataset to an adversarial example. Also presented is an adversarial threat model specific to structural health monitoring. The threat model is proposed with a view to motivate discussion into ways in which structural health monitoring approaches might be made more robust to the threat of adversarial attack.

60 APPLIED LIFE SCIENCES↗

T-TY Tank Farm Interim Surface Barrier Demonstration—Vadose Zone Monitoring Plan

The Hanford Site has 149 underground single-shell tanks that store hazardous radioactive waste. Many of these tanks and their associated infrastructure (e.g., pipelines, diversion boxes) have leaked. Some of the leaked waste has entered the groundwater. The largest known leak occurred from the T-106 Tank of the 241-T Tank Farm in 1973. Five tanks are assumed to have leaked in the TY Farm. Many of the contaminants from those leaks still reside within the vadose zone within the T and TY Tank Farms. The Department of Energy’s Office of River Protection seeks to minimize the movement of these contaminant plumes by placing interim barriers on the ground surface. Such barriers are expected to prevent infiltrating water from reaching the plumes and moving them further. The soil water regime is monitored to determine the effectiveness of the interim surface barriers. Soil-water content and water pressure are monitored using off-the-shelf equipment that can be installed by the hydraulic hammer technique. Four instrument nests were installed in the T Farm in fiscal year (FY) 2006 and FY2007; two nests were installed in the TY Farm in FY2010. Each instrument nest contains a neutron probe access tube, a capacitance probe, and four heat-dissipation units. A meteorological station has been installed at the north side of the fence of the T Farm. This document summarizes the monitoring methods, the instrument calibration and installation, and the vadose zone monitoring plan for interim barriers in T farm and TY Farm.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A Prototype Wire Position Monitoring System

The Wire Position Monitoring System (WPM) will track changes in the transverse position of LCLS Beam Position Monitors (BPMs) to 1{micro}m over several weeks. This position information will be used between applications of beam based alignment to correct for changes in component alignment. The WPM system has several requirements. The sensor range must be large enough so that precision sensor positioning is not required. The resolution needs to be small enough so that the signal can be used to monitor motion to 1{micro}m. The system must be stable enough so that system drift does not mimic motion of the component being monitored. The WPM sensor assembly consists of two parts, the magnetic sensor and an integrated lock-in amplifier. The magnetic sensor picks up a signal from the alternating current in a stretched wire. The voltage v induced in the sensor is proportional to the wire displacement from the center of the sensor. The integrated lock-in amplifier provides a DC output whose magnitude is proportional to the AC signal from the magnetic sensor. The DC output is either read on a digital voltmeter or digitized locally and communicated over a computer interface.

43 PARTICLE ACCELERATORS↗

2010 Groundwater Monitoring and Inspection Report Gnome-Coach Site, New Mexico

This report presents the 2010 groundwater monitoring results collected by the U.S. Department of Energy (DOE) Office of Legacy Management (LM) at the Gnome-Coach (Gnome) Site in New Mexico (Figure 1). Groundwater monitoring consisted of collecting hydraulic head data and groundwater samples from the wells on site. Historically, the U.S. Environmental Protection Agency (EPA) had conducted these annual activities under the Long-Term Hydrologic Monitoring Program (LTHMP). LM took over the sampling and data collection activities in 2008 but continues to use the EPA Radiation and Indoor Environments National Laboratory in Las Vegas, Nevada, to analyze the water samples. This report summarizes groundwater monitoring and site investigation activities that were conducted at the site during calendar year 2010.

54 ENVIRONMENTAL SCIENCES↗

Annual report of groundwater monitoring at Everest, Kansas in 2011

Everest, Kansas, is a small rural community (population approximately 300) located in the southeast corner of Brown County, in the northeastern corner of Kansas. Carbon tetrachloride and chloroform contamination in groundwater at Everest was initially identified in 1997 as a result of testing performed under the Commodity Credit Corporation/U.S. Department of Agriculture (CCC/USDA) private well sampling program conducted by the Kansas Department of Health and Environment (KDHE). The KDHE collected samples from seven private wells in and near Everest. Carbon tetrachloride and chloroform were found in only one of the wells, the Donnie Nigh domestic well (owned at that time by Tim Gale), approximately 3/8 mi northwest of the former Everest CCC/USDA facility. Carbon tetrachloride and chloroform were detected at 121 {mu}g/L and 4 {mu}g/L, respectively. Nitrate was found at 12.62 mg/L. The USDA subsequently connected the Nigh residence to the Everest public water supply system. The findings of the 2011 monitoring at Everest support the following conclusions: (1) Measurements of groundwater levels obtained manually during annual monitoring in 2009-2011 (and through the use of automatic recorders in 2002-2010) have consistently indicated an initial direction of groundwater flow from the former CCC/USDA facility to the north-northwest and toward the Nigh property, then west-southwest from the Nigh property toward the intermittent creek that lies west of the former CCC/USDA facility and the Nigh property. (2) At most of the monitored locations, carbon tetrachloride concentrations decreased in April 2011 relative to 2010 results. Noteworthy decreases of > 50% occurred at locations MW4, MW60, and MW88, in the most concentrated part of the plume. (3) Comparison of accumulated data demonstrates that the area of the carbon tetrachloride plume with concentrations > 200 {mu}g/L has decreased markedly over time and suggests a generally decreasing trend in contaminant levels. (4) The trace increases in carbon tetrachloride concentrations observed in 2010 at locations SB63 and SB64 were notable because of the locations proximity to the downgradient intermittent creek. However, these increases were not confirmed in sampling in 2011. (5) The results of the April 2011 monitoring event continue to support the interpretation, made during the 9-yr observation period from 2001 to 2010, that the migration rate for contamination in groundwater toward the intermittent creek is very slow. (6) No carbon tetrachloride was detected in five samples of surface water collected from the intermittent creek west of the former CCC/USDA facility and the Nigh property, or in tree branch tissue samples collected at locations along the banks of the creek. These observations indicate that the carbon tetrachloride contamination identified at Everest has, to date, not impacted the surface waters of the intermittent creek.

54 ENVIRONMENTAL SCIENCES↗

Air Monitoring of Emissions from the Fukushima Daiichi Reactor

In response to the disasters in Japan on March 11, 2011, and the subsequent emissions from Fukushima-Daiichi, we monitored the air near Los Alamos using four air-monitoring systems: the standard AIRNET samplers, the standard rad-NESHAP samplers, the NEWNET system, and high-volume air samplers. Each of these systems has advantages and disadvantages. In combination, they provide a comprehensive set of measurements of airborne radionuclides near Los Alamos during the weeks following March 11. We report air-monitoring measurements of the fission products released from the Fukushima-Daiichi nuclear-power-plant accident in 2011. Clear gamma-spectrometry peaks were observed from Cs-134, Cs-136, Cs-137, I-131, I132, Te-132, and Te-129m. These data, together with measurements of other radionuclides, are adequate for an assessment and assure us that radionuclides from Fukushima Daiichi did not present a threat to human health at or near Los Alamos. The data demonstrate the capabilities of the Los Alamos air-monitoring systems.

54 ENVIRONMENTAL SCIENCES↗

Nonlinear Ultrasonic Techniques to Monitor Radiation Damage in RPV and Internal Components

The objective of this research is to demonstrate that nonlinear ultrasonics (NLU) can be used to directly and quantitatively measure the remaining life in radiation damaged reactor pressure vessel (RPV) and internal components. Specific damage types to be monitored are irradiation embrittlement and irradiation assisted stress corrosion cracking (IASCC). Our vision is to develop a technique that allows operators to assess damage by making a limited number of NLU measurements in strategically selected critical reactor components during regularly scheduled outages. This measured data can then be used to determine the current condition of these key components, from which remaining useful life can be predicted. Methods to unambiguously characterize radiation related damage in reactor internals and RPVs remain elusive. NLU technology has demonstrated great potential to be used as a material sensor – a sensor that can continuously monitor a material’s damage state. The physical effect being monitored by NLU is the generation of higher harmonic frequencies in an initially monochromatic ultrasonic wave. The degree of nonlinearity is quantified with the acoustic nonlinearity parameter, β, which is an absolute, measurable material constant. Recent research has demonstrated that nonlinear ultrasound can be used to characterize material state and changes in microscale characteristics such as internal stress states, precipitate formation and dislocation densities. Radiation damage reduces the fracture toughness of RPV steels and internals, and can leave them susceptible to IASCC, which may in turn limit the lifetimes of some operating reactors. The ability to characterize radiation damage in the RPV and internals will enable nuclear operators to set operation time thresholds for vessels and prescribe and schedule replacement activities for core internals. Such a capability will allow a more clear definition of reactor safety margins. The research consists of three tasks: (1) materials sensing and monitoring; (2) physics-based materials and damage evolution modeling; and (3) remaining life estimation by integrating sensing, modeling and uncertainty.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗