Search NASA⌕ Search

SEARCH · Search NASA

Results for “Optical Systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,189 records · Page 66

X-ray instrumentation in astronomy; Proceedings of the Meeting, Cannes, France, December 2-4, 1985

Recent developments in X-ray and EUV astronomical instrumentation are discussed in reviews and reports. Topics examined include optical systems for the NASA Advanced X-ray Astrophysics Facility (AXAF), specialized X-ray systems, advanced X-ray optics, gas-filled X-ray detectors, instrumentation for spectrometry on AXAF, X-ray and EUV spectrometers, microchannel plate detectors, and solid-state detectors.

Culhane, J. L.↗

Effects of the contamination environment on surfaces and materials

In addition to the issues that have always existed, demands are being placed on space systems for increased contamination prevention/control. Optical surveillance sensors are required to detect low radiance targets. This increases the need for very low scatter surfaces in the optical system. Particulate contamination levels typically experienced in today's working environments/habits will most likely compromise these sensors. Contamination (molecular and particulate) can also affect the survivability of space sensors in both the natural and hostile space environments. The effects of di-octyl phthalate (DOP) on sensors are discussed.

Maag, Carl R.↗

Comparison of optics and electronics for the calculation of matrix-vector products

Optical processors are attractive because of their ability to perform massively parallel operations such as matrix vector products. The inherently analog nature of optical calculations requires that optical processors be based on analog computations. While the speed at which such analog operations can be performed as well as the natural parallelism of optical systems are great advantages of optical processors, the analog representation of values severely limits the achievable accuracy. Furthermore, optical processors are limited by the need to convert information to and from the intensity of light. Digitization can be used to increase the accuracy of optical matrix-vector processors, but causes a severe reduction in speed. This paper compares the throughput and power requirements of optical and electronic processors, showing that optical matrix-vector processors can provide a greater number of operations/Watt than conventional electronics.

Gary, C. K.↗

Imaging The Leading Edge Of A Weld

Proposed optical system integrated into plasma arc welding torch provides image of leading edge of weld pool and welding-arc-initiation point. Welding torch aligned better with joint. System includes coherent bundle of optical fibers and transparent cup.

Mcgee, William F.↗

Thermographic imaging for high-temperature composite materials: A defect detection study

The ability of a thermographic imaging technique for detecting flat-bottom hole defects of various diameters and depths was evaluated in four composite systems (two types of ceramic matrix composites, one metal matrix composite, and one polymer matrix composite) of interest as high-temperature structural materials. The holes ranged from 1 to 13 mm in diameter and 0.1 to 2.5 mm in depth in samples approximately 2-3 mm thick. The thermographic imaging system utilized a scanning mirror optical system and infrared (IR) focusing lens in conjunction with a mercury cadmium telluride infrared detector element to obtain high resolution infrared images. High intensity flash lamps located on the same side as the infrared camera were used to heat the samples. After heating, up to 30 images were sequentially acquired at 70-150 msec intervals. Limits of detectability based on depth and diameter of the flat-bottom holes were defined for each composite material. Ultrasonic and radiographic images of the samples were obtained and compared with the thermographic images.

Roth, Don J.↗

Fabrication and Testing of a Large Primary Reflector Structure

This paper discusses the fabrication considerations and proposed testing concepts related to a large twelve meter, graphite-epoxy space truss that is being developed to provide support of the primary mirror system for the Beam Transmission Optical System (BTOS).

space truss primary reflector free electron laser ↗

An approach to estimating flame radiation in combustion chambers containing suspended-particles

Thermal radiation often plays a key role in heat transfer between flames and the surrounding environment. Therefore, reliable measurement of flame radiation is indispensable in the study of combustion. While the measurement of radiative flux from flames is straightforward in an open environment, it is challenging to do so in a confined chamber, due to the influence of the walls. Radiation emitted by the walls and the reflection of flame radiation off the walls can interfere with measurements of flame radiation. For wall surfaces that are at high temperature or highly reflective, the error in the flame radiation measurement can be significant. Here in this paper, a theoretical analysis was carried out to study the contribution of wall emission and wall reflection to the incident radiation measured by radiometers. The results reveal that for a typical lab-scale air-fired flame, the contribution of wall emission and wall reflection to the measured incident radiation can be as high as 55% for a refractory-lined wall and 40% for a water-cooled wall. A convenient approach is proposed to distinguish flame radiation from the measured incident radiation. The approach is based on measurements of surface incident radiation and net radiative heat flux through the wall. The approach can be applied to optically thin systems (most lab-scale and some pilot-scale atmospheric pressure combustion systems) and optically dense systems (typically pressurized large-scale combustion systems). CFD simulations were also performed for two coal-fired combustors, one which represents optically thin and the other optically thick systems, to validate the theoretical model and the approach to estimating flame radiation. Good agreement was observed between CFD results and the theoretical model results, and the proposed approach to estimation of flame radiation was found to have reasonable accuracy.

42 ENGINEERING↗

Deflection gating for time-resolved x-ray magnetic circular dichroism-photoemission electron microscopy using synchrotron radiation

In this paper, we present a newly developed gating technique for a time-resolving photoemission microscope. The technique makes use of an electrostatic deflector within the microscope's electron optical system for fast switching between two electron-optical paths, one of which is used for imaging, while the other is blocked by an aperture stop. The system can be operated with a switching time of 20 ns and shows superior dark current rejection. We report on the application of this new gating technique to exploit the time structure in the injection bunch pattern of the synchrotron radiation source BESSY II at Helmholtz-Zentrum Berlin for time-resolved measurements in the picosecond regime.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Photonic processing at NASA Ames Research Center

The Photonic Processing group is engaged in applied research on optical processors in support of the Ames vision to lead the development of autonomous intelligent systems. Optical processors, in conjunction with numeric and symbolic processors, are needed to provide the powerful processing capability that is required for many future agency missions. The research program emphasizes application of analog optical processing, where free-space propagation between components allows natural implementations of algorithms requiring a large degree of parallel computation. Special consideration is given in the Ames program to the integration of optical processors into larger, heterogeneous computational systems. Demonstration of the effective integration of optical processors within a broader knowledge-based system is essential to evaluate their potential for dependable operation in an autonomous environment such as space. The Ames Photonics program is currently addressing several areas of interest. One of the efforts is to develop an optical correlator system with two programmable spatial light modulators (SLMs) to perform distortion invariant pattern recognition. Another area of research is optical neural networks, also for use in distortion-invariant pattern recognition.

Ochoa, Ellen↗

Development of a 3-D visible limiter imaging system for the HSX stellarator

A visible camera diagnostic has been developed to study the Helically Symmetric eXperiment (HSX) limiter plasma interaction. A straight line view from the camera location to the limiter was not possible due to the complex 3D stellarator geometry of HSX, so it was necessary to insert a mirror/lens system into the plasma edge. A custom support structure for this optical system tailored to the HSX geometry was designed and installed. This system holds the optics tube assembly at the required angle for the desired view to both minimize system stress and facilitate robust and repeatable camera positioning. The camera system has been absolutely calibrated and using H α and C-III filters can provide hydrogen and carbon photon fluxes, which through an S/XB coefficient can be converted into particle fluxes. The resulting measurements have been used to obtain the characteristic penetration length of hydrogen and C-III species. Here, the hydrogen λ iz value shows reasonable agreement with the value predicted by a 1D penetration length calculation.

47 OTHER INSTRUMENTATION↗

Nonlocal Coherent Optical Nonlinearities of a Macroscopic Quantum System

The optical responses of solids are typically understood to be local in space. Whether locality holds for the optical response of a macroscopic quantum system has, however, been largely unexplored. Here, we use multidimensional coherent spectroscopy at the optical diffraction limit to demonstrate nonlocal optical nonlinearities in a semiconductor microcavity. In conclusion, these nonlocal optical responses are both coherent and quantum in nature, deriving from the macroscopic length scale of confined exciton-polariton wave functions.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A Compact Fiber Optic Eye Diagnostic System

A new fiber optic probe developed for determining transport properties of sub-micron particles in fluid experiments in a microgravity environment has been applied to study different parts of an eye. The probe positioned in front of an eye, delivers a low power (approximately few microW) light from a laser diode into the eye and guides the light which is back scattered by different components (aqueous humor, lens, and vitreous humor) of the eye through a receiving optical fiber to a photo detector. The probe provides rapid determination of macromolecular diffusivities and their respective size distributions in the eye lens and the gel-like materials in the vitreous humor. In a clinical setting, the probe can be mounted on a standard slit-lamp apparatus simply using a Hruby lens holder. The capability of detecting cataracts, both nuclear and cortical, in their early stages of formation, in a non invasive and quantitative fashion, has the potential in patient monitoring and in developing and testing new drugs or diet therapies to 'dissolve' or slow down the cataract formation before the surgery becomes necessary. The ability to detect biochemical and macromolecular changes in the vitreous structure can be very useful in identifying certain diseases of the posterior chamber and their complications, e.g., posterior vitreous detachment and diabetic retinopathy.

Ansari, Rafat R.↗

A Compact Fiber Optic Eye Diagnostics System

A new fiber optic probe development for determining transport properties of sub-micron particles in fluids experiments in a microgravity environment has been applied to study different parts of the eye. The probe positioned in front of an eye, delivers a low power (approximately a few mu W) light from a laser diode into the eye and guides the light which is back scattered by different components (aqueous humor, lens, and vitreous humor) of the eye through a receiving optical fiber to a photo detector. The probe provides rapid determination of macromolecular diffusivities and their respective size distributions in the eye lens and the gel-like material in the vitreous humor. For a clinical use, the probe is mounted on a standard slit-lamp apparatus simply using Hruby lens holder. The capability of detecting cataracts, both nuclear and cortical, in their early stages of formation, in a non invasive and quantitative fashion, has the potential in patient monitoring and in developing and testing new drugs or diet therapies to 'dissolve' or slow down the cataract formation before the surgery becomes necessary. The ability to detect biochemical and macromolecular changes in the vitreous structure can be very useful in identifying certain diseases of the posterior chamber and their complications, e.g., posterior vitreous detachment and diabetic retinopathy.

Ansari, Rafat R.↗

Optical method for distance and displacement measurements of the probe-sample separation in a scanning near-field optical microscope

In this work, we present an alternative optical method to determine the probe-sample separation distance in a scanning near-field optical microscope. The experimental method is based in a Lloyd’s mirror interferometer and offers a measurement precision deviation of ∼100 nm using digital image processing and numerical analysis. The technique can also be strategically combined with the characterization of piezoelectric actuators and stability evaluation of the optical system. It also opens the possibility for the development of an automatic approximation control system valid for probe-sample distances from 5 to 500 μm.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Projection moire for remote contour analysis

Remote projection and viewing of moire contours are examined analytically for a system employing separate projection and viewing optics, with specific attention paid to the practical limitations imposed by the optical systems. It is found that planar contours are possible only when the optics are telecentric (exit pupil at infinity) but that the requirement for spatial separability of the contour fringes from extraneous fringes is independent of the specific optics and is a function only of the angle separating the two optic axes. In the nontelecentric case, the contour separation near the object is unchanged from that of the telecentric case, although the contours are distorted into low-eccentricity (near-circular) ellipses. Furthermore, the minimum contour spacing is directly related to the depth of focus through the resolution of the optics.

Doty, J. L.↗

Field tests of the optical cross beam system

Recent detailed evaluation of the use of an optical cross-beam system to measure convective wind velocities are reported. Low level measurements, where the optical system is looking at either the earth surface or cloud banks, are demonstrated. Further information on the nature and scale of the light fluctuations is reviewed.

Sandborn, V. A.↗

A near infra-red video system as a protective diagnostic for electron cyclotron resonance heating operation in the Wendelstein 7-X stellarator

The Wendelstein 7-X stellarator is a large nuclear fusion device based at Max-Planck-Institut für Plasmaphysik in Greifswald in Germany. The main plasma heating system for steady state operation in W7-X is electron cyclotron resonance heating (ECRH). During operation, part of plama facing components will be directly heated by the non-absorbed power of 1 MW rf beams of ECRH. In order to avoid damages of such components made of graphite tiles during the first operational phase, a near infra-red video system has been developed as a protective diagnostic for safe and secure ECRH operation. Both the mechanical design housing the camera and the optical system are very flexible and respect the requirements of steady state operation. The full system including data acquisition and control system has been successfully tested in the vacuum vessel, including on-line visualization and data storage of the four cameras equipping the ECRH equatorial launchers of W7-X.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗