Quantifying uncertainty in LCA-modelling of waste management systems

Highlights: Black-Right-Pointing-Pointer Uncertainty in LCA-modelling of waste management is significant. Black-Right-Pointing-Pointer Model, scenario and parameter uncertainties contribute. Black-Right-Pointing-Pointer Sequential procedure for quantifying uncertainty is proposed. Black-Right-Pointing-Pointer Application of procedure is illustrated by a case-study. - Abstract: Uncertainty analysis in LCA studies has been subject to major progress over the last years. In the context of waste management, various methods have been implemented but a systematic method for uncertainty analysis of waste-LCA studies is lacking. The objective of this paper is (1) to present the sources of uncertainty specifically inherent to waste-LCA studies, (2) to select and apply several methods for uncertainty analysis and (3) to develop a general framework for quantitative uncertainty assessment of LCA of waste management systems. The suggested method is a sequence of four steps combining the selected methods: (Step 1) a sensitivity analysis evaluating the sensitivities of the results with respect to the input uncertainties, (Step 2) an uncertainty propagation providing appropriate tools for representing uncertainties and calculating the overall uncertainty of the model results, (Step 3) an uncertainty contribution analysis quantifying the contribution of each parameter uncertainty to the final uncertainty and (Step 4) as a new approach, a combined sensitivity analysis providing a visualisation of the shift in the ranking of different options due to variations of selected key parameters. This tiered approach optimises the resources available to LCA practitioners by only propagating the most influential uncertainties.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Diversity and population structure of Marine Group A bacteria in the Northeast subarctic Pacific Ocean

Marine Group A (MGA) is a candidate phylum of Bacteria that is ubiquitous and abundant in the ocean. Despite being prevalent, the structural and functional properties of MGA populations remain poorly constrained. Here, we quantified MGA diversity and population structure in relation to nutrients and O2 concentrations in the oxygen minimum zone (OMZ) of the Northeast subarctic Pacific Ocean using a combination of catalyzed reporter deposition fluorescence in situ hybridization (CARD-FISH) and 16S small subunit ribosomal RNA (16S rRNA) gene sequencing (clone libraries and 454-pyrotags). Estimates of MGA abundance as a proportion of total bacteria were similar across all three methods although estimates based on CARD-FISH were consistently lower in the OMZ (5.6%±1.9%) than estimates based on 16S rRNA gene clone libraries (11.0%±3.9%) or pyrotags (9.9%±1.8%). Five previously defined MGA subgroups were recovered in 16S rRNA gene clone libraries and five novel subgroups were defined (HF770D10, P262000D03, P41300E03, P262000N21 and A714018). Rarefaction analysis of pyrotag data indicated that the ultimate richness of MGA was very nearly sampled. Spearman’s rank analysis of MGA abundances by CARD-FISH and O2 concentrations resulted in significant correlation. Analyzed in more detail by 16S rRNA pyrotag sequencing, MGA operational taxonomic units affiliated with subgroups Arctic95A-2 and A714018 comprised 0.3–2.4% of total bacterial sequences and displayed strong correlations with decreasing O2 concentration. This study is the first comprehensive description of MGA diversity using complementary techniques. These results provide a phylogenetic framework for interpreting future studies on ecotype selection among MGA subgroups, and suggest a potentially important role for MGA in the ecology and biogeochemistry of OMZs.

Marine Group A↗

ARMD Workshop on Materials and Methods for Rapid Manufacturing for Commercial and Urban Aviation

This report documents the goals, organization and outcomes of the NASA Aeronautics Research Mission Directorate’s (ARMD) Materials and Methods for Rapid Manufacturing for Commercial and Urban Aviation Workshop. The workshop began with a series of plenary presentations by leaders in the field of structures and materials, followed by concurrent symposia focused on forecasting the future of various technologies related to rapid manufacturing of metallic materials and polymeric matrix composites, referred to herein as composites. Shortly after the workshop, questionnaires were sent to key workshop participants from the aerospace industry with requests to rank the importance of a series of potential investment areas identified during the workshop. Outcomes from the workshop and subsequent questionnaires are being used as guidance for NASA investments in this important technology area.

Ransom, Jonathan B.↗

Fast Reactor Core Analysis Using AZNHEX Neutron Diffusion Code

The AZTLAN platform project emerged as an initiative to rank Mexico at a competitive level in software aspects for the analysis of nuclear reactors, in an effort to achieve autonomy in this area. The AZTLAN platform is conformed by a thermo-hydraulic code (AZTHECA), a neutron transport code (AZTRAN) and two neutron diffusion codes (AZKIND, AZNHEX). AZNHEX is a 3D diffusion code that solves numerically the time dependent neutron diffusion equations in hexagonal z-geometry using the RTN0 nodal finite element method. With this code, it is possible to simulate and analyze light water reactors, such as the Russian VVER, and variety of fast reactors. In this work, a sodium-cooled fast reactor core in steady state, with control rods fully withdrawn, is simulated. The comparison and validation of the values obtained with AZNHEX was done with the results obtained with MCNP6 Monte Carlo code.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Agentic framework for programmatic crystal structure generation using a fine-tuned worker–supervisor large language model

Platinum group metals (PGMs) underpin many catalytic technologies but face severe supply constraints, motivating the search for alternative materials and computational methods to accelerate discovery. While atomistic simulation tools such as Pymatgen and ASE have streamlined structure manipulation, they require detailed inputs, limiting accessibility for experimentalists and slowing early-stage exploration. Here, in this study, we present an AI-driven agentic framework that orchestrates worker–supervisor large language models (LLMs). The worker translates natural-language prompts of varying abstraction into valid crystallographic structures using a compact LLM fine-tuned with low-rank adaptation on a curated text–code–CIF dataset, emphasizing energy-efficient training. Benchmarking against the baseline CodeGen-350M-mono model shows that fine-tuning reduces hallucination rates from 100% to as low as 5% and improves structural match accuracy to up to 82% for fully specified inputs. Accuracy declines with decreasing prompt detail but remains nontrivial even when only stoichiometry and space group are provided, underscoring the LLM’s capacity for crystallographic inference. The supervisor Claude LLM evaluates the outputs and triggers iterative refinement through the worker’s built-in structure manipulation capabilities (e.g., supercell scaling, strain, vacancy, and substitution operations). We further demonstrate use cases for technologically relevant catalysts, including IrO 2 , pyrochlore Pb 2 Ir 2 O 7 , Ni 2 FeO 4 , and Ni 3 Mo, where the framework generates physically consistent structures that can be refined via geometry optimization. This work introduces a low-energy, language-driven pathway for integrating human and machine intelligence in materials design, paving the way for AI-assisted synthesis planning and high-throughput screening of complex oxides.

AI agent↗

Reducing the environmental impact of road and rail vehicles

Methods have been developed to measure in situ the dynamic impact of both road and rail vehicles on the infrastructure and the environment. The resulting data sets have been analysed to quantify the environmental impacts in a transparent manner across both modes. A primary concern is that a small number of vehicles are being operated outside safe or regulatory limits which can have a disproportionate large impact. The analysis enables the various impacts to be ranked across both modes so enabling one to discern the benefits of intermodal transport. The impact of various policy options is considered and how to identify vehicles which can be classified as environmentally friendly. This would require European agreement as many heavy goods vehicle operate across country borders.

54 ENVIRONMENTAL SCIENCES↗

Correlation of Local Failure With Measures of Dose Insufficiency in the High-Dose Single-Fraction Treatment of Bony Metastases

Purpose: In the setting of high-dose single-fraction image-guided radiotherapy of spine metastases, the delivered dose is hypothesized to be a significant factor in local control. We investigated the dependence of local control on measures of dose insufficiency. Methods and Materials: The minimum doses received by the hottest 100%, 98%, and 95% (D{sub min}, D{sub 98}, and D{sub 95}) of the gross target volume (GTV) were computed for 91 consecutively treated lesions observed in 79 patients. Prescribed doses of 18-24 Gy were delivered in a single fraction. The spinal cord and cauda equina were constrained to a maximum dose of 12-14 Gy and 16 Gy, respectively. A rank-sum test was used to assess the differences between radiographic local failure and local control. Results: With a median follow-up of 18 months, seven local failures have occurred. The distributions of GTV D{sub min}, D{sub 98}, and D{sub 95} for treatments resulting in local failure were found to be statistically different from the corresponding distributions of the patient group as a whole. Taking no account of histology, p values calculated for D{sub min}, D{sub 98}, and D{sub 95} were 0.004, 0.012, and 0.031, respectively. No correlations between local failure and target volume or between local failure and anatomic location were found. Conclusions: The results indicate that D{sub min}, D{sub 98}, and D{sub 95} may be important risk factors for local failure. No local failures in any histology were observed when D{sub min} was >15 Gy, suggesting that this metric may be an important predictor of local control.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Poor Prognosis Associated With Human Papillomavirus α7 Genotypes in Cervical Carcinoma Cannot Be Explained by Intrinsic Radiosensitivity

Purpose: To investigate the relationship between human papillomavirus (HPV) genotype and outcome after radiation therapy and intrinsic radiosensitivity. Methods and Materials: HPV genotyping was performed on cervix biopsies by polymerase chain reaction using SPF-10 broad-spectrum primers, followed by deoxyribonucleic acid enzyme immunoassay and genotyping by reverse hybridization line probe assay (LiPA{sub 25}) (version 1) (n=202). PapilloCheck and quantitative reverse transcription-polymerase chain reaction were used to genotype cervix cancer cell lines (n=16). Local progression-free survival after radiation therapy alone was assessed using log-rank and Cox proportionate hazard analyses. Intrinsic radiosensitivity was measured as surviving fraction at 2 Gy (SF2) using clonogenic assays. Results: Of the 202 tumors, 107 (53.0%) were positive for HPV16, 29 (14.4%) for HPV18, 9 (4.5%) for HPV45, 23 (11.4%) for other HPV genotypes, and 22 (10.9%) were negative; 11 (5.5%) contained multiple genotypes, and 1 tumor was HPV X (0.5%). In 148 patients with outcome data, those with HPVα9-positive tumors had better local progression-free survival compared with α7 patients in univariate (P<.004) and multivariate (hazard ratio 1.54, 95% confidence interval 1.11-1.76, P=.021) analyses. There was no difference in the median SF2 of α9 and α7 cervical tumors (n=63). In the cell lines, 9 were α7 and 4 α9 positive and 3 negative. There was no difference in SF2 between α9 and α7 cell lines (n=14). Conclusion: The reduced radioresponsiveness of α7 cervical tumors is not related to intrinsic radiosensitivity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

WE-DE-201-04: Cross Validation of Knowledge-Based Treatment Planning for Prostate LDR Brachytherapy Using Principle Component Analysis

Purpose: To validate a knowledge-based algorithm for prostate LDR brachytherapy treatment planning. Methods: A dataset of 100 cases was compiled from an active prostate seed implant service. Cases were randomized into 10 subsets. For each subset, the 90 remaining library cases were registered to a common reference frame and then characterized on a point by point basis using principle component analysis (PCA). Each test case was converted to PCA vectors using the same process and compared with each library case using a Mahalanobis distance to evaluate similarity. Rank order PCA scores were used to select the best-matched library case. The seed arrangement was extracted from the best-matched case and used as a starting point for planning the test case. Any subsequent modifications were recorded that required input from a treatment planner to achieve V100>95%, V150<60%, V200<20%. To simulate operating-room planning constraints, seed activity was held constant, and the seed count could not increase. Results: The computational time required to register test-case contours and evaluate PCA similarity across the library was 10s. Preliminary analysis of 2 subsets shows that 9 of 20 test cases did not require any seed modifications to obtain an acceptable plan. Five test cases required fewer than 10 seed modifications or a grid shift. Another 5 test cases required approximately 20 seed modifications. An acceptable plan was not achieved for 1 outlier, which was substantially larger than its best match. Modifications took between 5s and 6min. Conclusion: A knowledge-based treatment planning algorithm for prostate LDR brachytherapy is being cross validated using 100 prior cases. Preliminary results suggest that for this size library, acceptable plans can be achieved without planner input in about half of the cases while varying amounts of planner input are needed in remaining cases. Computational time and planning time are compatible with clinical practice.

60 APPLIED LIFE SCIENCES↗

Evaluating The Relationships Between Supine Propriorception Assessments with Upright Functional Mobility and Balance Tests

INTRODUCTION Upon return to Earth, spaceflight sensorimotor adaptations can result in impaired posture and locomotion [1], [2], and current exercise countermeasures in the International Space Station are not sufficient to maintain sensorimotor function. In-flight countermeasures and assessment tools for sensorimotor function are needed to mitigate risks associated with mission-critical task performance upon return to Earth or arrival to 0.38 G on Mars. One proposed countermeasure for proprioceptive deconditioning includes training on a tilt board device [3], which will be tested in an upcoming bed rest study. In preparation for the said study, the objective of this pilot study is to compare performance in supine proprioceptive assessments to performance in functional upright activities. The results are intended to guide the selection of supine assessment tools for the upcoming bedrest study and the development of future inflight proprioceptive training and assessment tools for exploration missions. METHODS Seventeen healthy participants (8 males and 9 females, 27.9 ± 8.5 years) provided informed consent as approved by the Institutional Review Board (IRB) at NASA. A horizontal air-bearing sled was used to provide a proprioceptive challenge in a supine body orientation, allowing for mediolateral motion with minimal friction during supine stance [4]. Participants were loaded axially (30 to 60% body weight) with their feet on a vertically oriented tilt board and instructed to perform supine assessment activities using custom software that displays a cursor controlled by tilting the tilt board. In a single-leg static activity on the tilt board (TB-St), performance was measured as the percent time spent on a center target during a 30-second trial. During a two-feet dynamic activity on the tilt board (TB-Dy), performance was measured as the number of targets captured in 30 seconds. These supine tasks were compared to performance during two upright activities used to represent upright performance: completion time for a functional mobility task (FMT) [2],[5] and a performance score from force plate sway data during 30-second single-leg upright standing (USL). RESULTS AND DISCUSSION A Spearman's rank-order correlation was run to assess the relationship between upright and supine assessments. There were statistically significant, strong correlations between scores for the FMT and each TB activity, including TB-St, rs(17) = 0.50, p<0.05, TB-Dy3, rs(17) = 0.73, p<0.001, and TB-Dy9, rs(15) = 0.53, p<0.05. There were no statistically significant correlations between USL and each TB activity. Despite a lack of correlation with upright single-leg balance, the ability of the TB to indicate upright performance in the FMT is promising, as this task is a standard post-flight measure designed to characterize locomotor dysfunction [2], [5]. CONCLUSION These efforts will inform the selection of an appropriate sensorimotor assessment method for the upcoming bed rest study and similar future studies. While current work uses a bed rest analog to develop these technologies, future work aims to prepare capabilities for future in-flight sensorimotor training and assessment to mitigate the risks of proprioception impairment after spaceflight. ACKNOWLEDGEMENTS This work was supported by the University Space Research Association Internship Program. REFERENCES [1] Mulavara A.P. et al (2018) Med Sci Sports Exerc, 50(9), 1961-1980. [2] Mulavara A.P. et al (2010) Exp Brain Res, 202(3), 649-659. [3] Macaulay T.R. et al (2021) Front. Syst. Neurosci., 15, 658-985. [4] Goel R. et al (2017) Front. Syst. Neurosci, 11. [5] Koppelmans V. et al (2013) BMC Neurology, 12.

R Bellisle↗

Timing of Salvage Hormonal Therapy in Prostate Cancer Patients With Unfavorable Prognosis Treated With Radiotherapy: A Secondary Analysis of Radiation Therapy Oncology Group 85-31

Purpose: Radiation Therapy Oncology Group 85-31 was a randomized trial comparing radiotherapy (RT) alone vs. RT plus adjuvant androgen suppression for life in unfavorable-prognosis carcinoma of the prostate. We examined the impact of early initiation of salvage hormonal therapy (HT) in relapsing patients randomized to RT alone arm. Methods and Materials: Patients were divided into two groups: early salvage HT and late salvage HT. The early salvage group was defined as receiving HT with a prostate-specific antigen (PSA) level of less than 10 ng/mL, and the late salvage HT group had a PSA level of 10 ng/mL or greater. The outcomes were overall survival (OS), cause-specific mortality (CSM), and local failure (LF). The Kaplan-Meier estimation and log-rank test were used for OS, and the cumulative incidence estimation and Gray's test were used for CSM and LF. Proportional hazards regression models were used to compare the outcomes adjusted for other covariates. Results: The median follow-up times of surviving patients in the early and late salvage HT groups were about 11 and 13 years, respectively. The late salvage HT group had significantly more post-prostatectomy patients and patients with high Gleason scores. After adjustment for all covariates, OS was significantly longer in the early salvage HT group (hazard ratio, 1.5; p = 0.01). However, there were no statistically significant differences in LF or CSM between the groups. Conclusions: The early introduction of salvage HT resulted in improved OS but not improved CSM and LF. A randomized trial to define the optimal salvage hormonal timing is warranted in this group of patients with PSA recurrence after RT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Prognostic Importance of Small Prostate Size in Men Receiving Definitive Prostate Brachytherapy

Purpose: To assess whether small prostate size is an adverse prognostic factor in men undergoing brachytherapy in the same manner in which it seems to be for men undergoing radical prostatectomy. Methods and Materials: From April 1995 to June 2008, 2024 patients underwent brachytherapy by a single brachytherapist. Median follow-up was 7.4 years. The role of small prostate size ({<=}20 cm{sup 3}) as a prognostic factor for biochemical progression-free survival, cause-specific survival, and all-cause mortality was investigated. The differences in survival between men with small and larger prostates were compared using Kaplan-Meier curves and log-rank tests. Results: Median prostate size for the entire cohort was 32.7 cm{sup 3}. For the 167 men with small prostates, median prostate size was 17.4 cm{sup 3}. There was no difference in biochemical progression-free survival (95.2% vs 96.2%, P=.603), cause-specific survival (97.7% vs 98.3%, P=.546), or all-cause mortality (78.0% vs 77.2%, P=.838) at 10 years for men with small prostates compared with men with larger prostates. On univariate and multivariate analysis, small prostate size was not associated with any of the primary outcome measures. Conclusion: Men with small prostates treated with brachytherapy have excellent outcomes and are at no higher risk of treatment failure than men with larger glands. High-quality implants with adequate margins seem sufficient to address the increased adverse risk factors associated with small prostate size.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Long-Term Quality of Life in Prostate Cancer Patients Treated With Cesium-131

Purpose: To evaluate long-term patient-reported quality of life (QOL) scores in men with prostate cancer treated at our institution with {sup 131}Cs prostate brachytherapy. Methods and Materials: Patients treated more than 4 years ago with {sup 131}Cs (n=290) were asked to fill out an Expanded Prostate Cancer Index Composite (EPIC) QOL questionnaire and American Urological Association Symptom Score (AUASS) survey, before treatment and at each follow-up appointment. We compared patients' EPIC and AUA scores at baseline with scores at a last follow-up of at least 4 years after treatment using the Wilcoxon signed-rank test. Results: At a median last follow-up of 5.5 years after treatment with {sup 131}Cs prostate brachytherapy there were no clinically significant changes in the EPIC or AUA scores from baseline. There was statistical worsening in the EPIC urinary incontinence subscore. Subset analyses revealed improved QOL outcomes in patients who received external beam radiation therapy or α-blocker therapy, whereas androgen deprivation therapy was not associated with differences in QOL change. Conclusions: Our results demonstrate minimal long-term changes in urinary or bowel patient-reported QOL with {sup 131}Cs prostate brachytherapy. These findings suggest that patients treated with this isotope are able to recover and then maintain their baseline QOL in the long term.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

On the dual advantage of placing observations through forward sensitivity analysis

The four-dimensional variational data assimilation methodology for assimilating noisy observations into a deterministic model has been the workhorse in forecasting centres for over three decades. While this method provides a computationally efficient framework for dynamic data assimilation, it is largely silent on the important question concerning the minimum number and placement of observations. To answer this question, we demonstrate the dual advantage of placing the observations where the square of the sensitivity of the model solution with respect to the unknown control variables, called forward sensitivities, attains its maximum. By following this approach, we can force the observability Gramian to be of full rank, which in turn guarantees efficient recovery of the optimal values of the control variables, which is the first of the two advantages of this strategy. We further show that the proposed strategy of placing observations has another inherent optimality: the square of the sensitivity of the optimal estimates of the control with respect to the observations (used to obtain these estimates) attains its minimum value, a second advantage that is a direct consequence of the above strategy for placing observations. Our analytical framework and numerical experiments on linear and nonlinear systems confirm the effectiveness of our proposed strategy.

97 MATHEMATICS AND COMPUTING↗

A streamlined failure mode and effects analysis

Purpose: Explore the feasibility and impact of a streamlined failure mode and effects analysis (FMEA) using a structured process that is designed to minimize staff effort. Methods: FMEA for the external beam process was conducted at an affiliate radiation oncology center that treats approximately 60 patients per day. A structured FMEA process was developed which included clearly defined roles and goals for each phase. A core group of seven people was identified and a facilitator was chosen to lead the effort. Failure modes were identified and scored according to the FMEA formalism. A risk priority number,RPN, was calculated and used to rank failure modes. Failure modes with RPN > 150 received safety improvement interventions. Staff effort was carefully tracked throughout the project. Results: Fifty-two failure modes were identified, 22 collected during meetings, and 30 from take-home worksheets. The four top-ranked failure modes were: delay in film check, missing pacemaker protocol/consent, critical structures not contoured, and pregnant patient simulated without the team's knowledge of the pregnancy. These four failure modes hadRPN > 150 and received safety interventions. The FMEA was completed in one month in four 1-h meetings. A total of 55 staff hours were required and, additionally, 20 h by the facilitator. Conclusions: Streamlined FMEA provides a means of accomplishing a relatively large-scale analysis with modest effort. One potential value of FMEA is that it potentially provides a means of measuring the impact of quality improvement efforts through a reduction in risk scores. Future study of this possibility is needed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

MO-G-BRF-01: BEST IN PHYSICS (JOINT IMAGING-THERAPY) - Sensitivity of PET-Based Texture Features to Respiratory Motion in Non-Small Cell Lung Cancer (NSCLC)

Purpose: PET-based texture features are used to quantify tumor heterogeneity due to their predictive power in treatment outcome. We investigated the sensitivity of texture features to tumor motion by comparing whole body (3D) and respiratory-gated (4D) PET imaging. Methods: Twenty-six patients (34 lesions) received 3D and 4D [F-18]FDG-PET scans before chemo-radiotherapy. The acquired 4D data were retrospectively binned into five breathing phases to create the 4D image sequence. Four texture features (Coarseness, Contrast, Busyness, and Complexity) were computed within the the physician-defined tumor volume. The relative difference (δ) in each measure between the 3D- and 4D-PET imaging was calculated. Wilcoxon signed-rank test (p<0.01) was used to determine if δ was significantly different from zero. Coefficient of variation (CV) was used to determine the variability in the texture features between all 4D-PET phases. Pearson correlation coefficient was used to investigate the impact of tumor size and motion amplitude on δ. Results: Significant differences (p<<0.01) between 3D and 4D imaging were found for Coarseness, Busyness, and Complexity. The difference for Contrast was not significant (p>0.24). 4D-PET increased Busyness (∼20%) and Complexity (∼20%), and decreased Coarseness (∼10%) and Contrast (∼5%) compared to 3D-PET. Nearly negligible variability (CV=3.9%) was found between the 4D phase bins for Coarseness and Complexity. Moderate variability was found for Contrast and Busyness (CV∼10%). Poor correlation was found between the tumor volume and δ for the texture features (R=−0.34−0.34). Motion amplitude had moderate impact on δ for Contrast and Busyness (R=−0.64− 0.54) and no impact for Coarseness and Complexity (R=−0.29−0.17). Conclusion: Substantial differences in textures were found between 3D and 4D-PET imaging. Moreover, the variability between phase bins for Coarseness and Complexity was negligible, suggesting that similar quantification can be obtained from all phases. Texture features, blurred out by respiratory motion during 3D-PET acquisition, can be better resolved by 4D-PET imaging with any phase.

60 APPLIED LIFE SCIENCES↗

MO-DE-207B-01: JACK FOWLER JUNIOR INVESTIGATOR COMPETITION WINNER: Between Somatic Mutations and PET-Based Radiomic Features in Non-Small Cell Lung Cancer

Purpose: Although PET-based radiomic features have been proposed to quantify tumor heterogeneity and shown promise in outcome prediction, little is known about their relationship with tumor genetics. This study assessed the association of [{sup 18}F]fluorodeoxyglucose (FDG)-PET-based radiomic features with non-small cell lung cancer (NSCLC) mutations. Methods: 348 NSCLC patients underwent FDG-PET/CT scans before treatment and were tested for genetic mutations. 13% (44/348) and 28% (96/348) patients were found to harbor EGFR (EGFR+) and KRAS (KRAS+) mutations, respectively. We evaluated nineteen PET-based radiomic features quantifying phenotypic traits, and compared them with conventional PET features (metabolic tumor volume (MTV) and maximum-SUV). The association between the feature values and mutation status was evaluated using the Wilcoxcon-rank-sum-test. The ability of each measure to predict mutations was assessed by the area under the receiver operating curve (AUC). Noether’s test was used to determine if the AUCs were significantly from random (AUC=0.50). All p-values were corrected for multiple testing by controlling the false discovery rate (FDR{sub Wilcoxon} and FDR{sub Noether}) of 10%. Results: Eight radiomic features, MTV, and maximum-SUV, were significantly associated with the EGFR mutation (FDR{sub Wilcoxon}=0.01–0.10). However, KRAS+ demonstrated no significantly distinctive imaging features compared to KRAS− (FDR{sub Wilcoxon}≥0.92). EGFR+ and EGFR− were significantly discriminated by conventional PET features (AUC=0.61, FDR{sub Noether}=0.04 for MTV and AUC=0.64, FDR{sub Noether}=0.01 for maximum-SUV). Eight radiomic features were significantly predictive for EGFR+ compared to EGFR− (AUC=0.59–0.67, FDR{sub Noether}=0.0032–0.09). Normalized-inverse-difference-moment outperformed all features in predicting EGFR mutation (AUC=0.67, FDR{sub Noether}=0.0032). Moreover, only the radiomic feature normalized-inverse-difference-moment could significantly predict KRAS+ from EGFR+ (AUC=0.65, FDR{sub Noether}=0.05). All measures failed to predict KRAS+ from KRAS− (AUC=0.50–0.54, FDR{sub Noether}≥0.92). Conclusion: PET imaging features were strongly associated with EGFR mutations in NSCLC. Radiomic features have great potential in predicting EGFR mutations. Our study may help develop a non-invasive imaging biomarker for EGFR mutation. R.M. has consulting interests with Amgen.

60 APPLIED LIFE SCIENCES↗

WE-H-BRC-01: Failure Mode and Effects Analysis of Skin Electronic Brachytherapy Using Esteya Unit

Purpose: A failure mode and effect analysis (FMEA) of skin lesions treatment process using Esteya™ device (Elekta Brachyterapy, Veenendaal, The Netherlands) was performed, with the aim of increasing the quality of the treatment and reducing the likelihood of unwanted events. Methods: A multidisciplinary team with experience in the treatment process met to establish the process map, which outlines the flow of various stages for such patients undergoing skin treatment. Potential failure modes (FM) were identified and the value of severity (S), frequency of occurrence (O), and lack of detectability (D) of the proposed FM were scored individually, each on a scale of 1 to 10 following TG-100 guidelines of the AAPM. These failure modes were ranked according to our risk priority number (RPN) and S scores. The efficiency of existing quality management tools was analyzed through a reassessment of the O and D made by consensus. Results: 149 FM were identified, 43 of which had RPN ≥ 100 and 30 had S ≥ 7. After introduction of the tools of quality management, only 3 FM had RPN ≥ 100 and 22 FM had RPN ≥ 50. These 22 FM were thoroughly analyzed and new tools for quality management were proposed. The most common cause of highest RPN FM was associated with the heavy patient workload and the continuous and accurate applicator-patient skin contact during the treatment. To overcome this second item, a regular quality control and setup review by a second individual before each treatment session was proposed. Conclusion: FMEA revealed some of the FM potentials that were not predicted during the initial implementation of the quality management tools. This exercise was useful in identifying the need of periodic update of the FMEA process as new potential failures can be identified.

60 APPLIED LIFE SCIENCES↗