Search NASA⌕ Search

SEARCH · Search NASA

Results for “Reliability model generation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,189 records · Page 66

Managing Complexity in Next Generation Robotic Spacecraft: From a Software Perspective

This presentation highlights the challenges in the design of software to support robotic spacecraft. Robotic spacecraft offer a higher degree of autonomy, however currently more capabilities are required, primarily in the software, while providing the same or higher degree of reliability. The complexity of designing such an autonomous system is great, particularly while attempting to address the needs for increased capabilities and high reliability without increased needs for time or money. The efforts to develop programming models for the new hardware and the integration of software architecture are highlighted.

Multi - threaded programming↗

Reliable cyber-threat detection in rapidly changing environments

In some embodiments, a plurality of monitoring nodes each generate a series of current monitoring node values over time that represent a current operation of the industrial asset. An attack detection computer platform may receive the series of current monitoring node values and generate a set of current feature vectors including a current feature for capturing transients (e.g., local transients and/or global transients). The attack detection computer platform may also access an attack detection model having at least one decision boundary that was created using at least one of a set of normal feature vectors and/or a set of attacked feature vectors. The attack detection model may then be executed such that an attack alert signal is transmitted by the attack detection computer platform, when appropriate, based on the set of current feature vectors (including the current feature to capture transients) and the at least one decision boundary.

Abbaszadeh, Masoud↗

Power generation-cooling water Nexus: Impacts of cooling water shortage on power system operation - a simulation case study in Illinois, U.S

Cooling water shortage, frequently attributed to drought and heat waves, poses a significant threat to the operations of thermoelectric power plants and further poses a challenge for the entire power system and environmental stakeholders. Recognizing the critical nexus between power generation and cooling water availability and the potential ability of power generations to adjust generation schedules during cooling water shortages, this paper introduces a security-constrained unit commitment and economic dispatch model considering water-energy nexus. In specific, the model is augmented with a unit-level cooling water requirement (CWR) model and multi-level cooling water availability (CWA) constraints. The unit-level CWR model quantifies the cooling water withdrawal per MWh of power generation, taking into account factors such as thermoelectric generation technologies, cooling system technologies, and environmental parameters. The multi-level CWA constraints incorporate pump-level, plant-level, watershed-level, and forced minimum power constraints, utilizing data derived from actual-based cooling water shortage scenarios. Using a simulation case study in Illinois, United States, this research examines the reliability, economic, and environmental implications of cooling water shortages on power system operations. The results show that Illinois may experience 10-15% daily load curtailment and severe congestion between certain regions from the east to central during cooling water shortages, while once-through and wet-tower units experience a 52% and 17% reduction in power generation. In conclusion, overall cooling water withdrawal decreases by 24-38% as severity intensifies.

Cooling water shortage↗

Integration of renewable energy generation and storage systems for emissions reduction in an islanded campus microgrid

Microgrid connected building communities are projected to play an integral part in the clean energy transition. These types of systems, when integrated with distributed energy resources (DERs) such as combined heat and power (CHP), district heating and cooling, renewable generation, and energy storage, can provide clean, reliable power to critical facilities and vulnerable communities. The intermittent nature of renewable generation is a challenge when integrating renewables into any grid system, but particularly in islanded microgrids. The University of Texas at Austin (UT) operates an islanded microgrid powered by a CHP plant, while also utilizing district heating and cooling systems and thermal energy storage (TES). High fidelity operating data was used to develop a validated reduced order model of UT’s integrated campus energy systems to serve as a testbed for use in a case study. Hypothetical renewable energy installations on land owned by UT in west Texas were modeled and integrated into the validated campus models along with battery energy storage (BES). Simulations showed that a combination of renewable energy from wind, and optimally controlled 24-hour thermal and battery storage systems could reduce carbon dioxide emissions on campus by 45.4%. The additional retrofit of burner systems to utilize hydrogen natural gas blends resulted in an overall annual emissions reduction of 54.7%. Carbon capture and storage eliminated the majority of the remaining emissions with increased plant energy expenditure. The presented simulations display the practical limitations of a CHP system complemented by renewable generation and short-term storage in eliminating emissions. Furthermore, results highlight the need for further research and development in long duration storage technologies and hydrogen fueled turbines to increase penetration of renewable energy and reduce emissions.

CHP↗

Image phase shift invariance based cloud motion displacement vector calculation method for ultra-short-term solar PV power forecasting

Irradiance received on the earth's surface is the main factor that affects the output power of solar PV plants, and is chiefly determined by the cloud distribution seen in a ground-based sky image at the corresponding moment in time. It is the foundation for those linear extrapolation-based ultra-short-term solar PV power forecasting approaches to obtain the cloud distribution in future sky images from the accurate calculation of cloud motion displacement vectors (CMDVs) by using historical sky images. Theoretically, the CMDV can be obtained from the coordinate of the peak pulse calculated from a Fourier phase correlation theory (FPCT) method through the frequency domain information of sky images. The peak pulse is significant and unique only when the cloud deformation between two consecutive sky images is slight enough, which is likely possible for a very short time interval (such as 1?min or shorter) with common changes in the speed of cloud. Sometimes, there will be more than one pulse with similar values when the deformation of the clouds between two consecutive sky images is comparatively obvious under fast changing cloud speeds. This would probably lead to significant errors if the CMDVs were still only obtained from the single coordinate of the peak value pulse. However, the deformation estimation of clouds between two images and its influence on FPCT-based CMDV calculations are terrifically complex and difficult because the motion of clouds is complicated to describe and model. Therefore, to improve the accuracy and reliability under these circumstances in a simple manner, an image-phase-shift-invariance (IPSI) based CMDV calculation method using FPCT is proposed for minute time scale solar power forecasting. First, multiple different CMDVs are calculated from the corresponding consecutive images pairs obtained through different synchronous rotation angles compared to the original images by using the FPCT method. Second, the final CMDV is generated from all of the calculated CMDVs through a centroid iteration strategy based on its density and distance distribution. Third, the influence of different rotation angle resolution on the final CMDV is analyzed as a means of parameter estimation. Simulations under various scenarios including both thick and thin clouds conditions indicated that the proposed IPSI-based CMDV calculation method using FPCT is more accurate and reliable than the original FPCT method, optimal flow (OF) method, and particle image velocimetry (PIV) method.

14 SOLAR ENERGY↗

Machine Learning‐Assisted Microearthquake Location Workflow for Monitoring the Newberry Enhanced Geothermal System

Abstract Enhanced geothermal systems (EGS) offer a sustainable energy source but face challenges in accurately locating microearthquakes induced during reservoir stimulation. Locating these microearthquakes provides reliable feedback on the stimulation progress. Current deep learning methods for locating earthquakes require extensive data sets for training, which is problematic as detected microearthquakes are often limited. To address the scarcity of training data, we propose a practical workflow using probabilistic multilayer perceptron (PMLP) which predicts microearthquake locations from cross‐correlation time lags in waveforms. Utilizing a 3D velocity model of Newberry site derived from ambient noise interferometry, we generate numerous synthetic microearthquakes and 3D acoustic waveforms for PMLP training. Accurate synthetic tests prompt us to apply the trained network to the 2012 and 2014 stimulation field waveforms. To enhance the accuracy of source localization, we carefully handpick the P‐arrival times. Predictions on the 2012 stimulation data set show major microseismic activity at depths of 0.5–1.2 km, correlating with a known casing leakage scenario. In the 2014 data set, the majority of predictions concentrate at 2.0–2.9 km depths, consistent with results obtained from conventional physics‐based inversion, and align with the presence of natural fractures from 2.0 to 2.7 km. We validate our findings by comparing the synthetic and field picks, demonstrating a satisfactory match for the first arrivals. By combining the benefits of quick inference speeds and accurate location predictions, we demonstrate the feasibility of using realistic synthetic data set to locate microseismicity for EGS monitoring.

15 GEOTHERMAL ENERGY↗

ENSEMBLE KALMAN FILTERS FOR RELIABILITY ESTIMATION IN PERFUSION INFERENCE

We consider the solution of inverse problems in dynamic contrast–enhanced imaging by means of ensemble Kalman filters. Our quantity of interest is blood perfusion, i.e., blood flow rates in tissue. While existing approaches to compute blood perfusion parameters for given time series of radiological measurements mainly rely on deterministic, deconvolution–based methods, we aim at recovering probabilistic solution information for given noisy measurements. To this end, we model radiological image capturing as a sequential data assimilation process and solve it by an ensemble Kalman filter. Thereby, we recover deterministic results as an ensemble–based mean and are able to compute reliability information such as probabilities for the perfusion to be in a given range. Our target application is the inference of blood perfusion parameters in the human brain. A numerical study shows promising results for artificial measurements generated by a digital perfusion phantom.

Engineering↗

A Study of the Impact of Reduced Inertia in Power Systems

Inertia in power systems plays an important role in maintaining the stability and reliability of the system by counteracting changes in frequency. However, the traditional sources of synchronous generation are being displaced by renewable resources, which often have no inherent inertia. This paper investigates the impact of reduced system inertia on several aspects of the dynamic stability of power systems, such as angular stability, primary frequency response, and oscillatory modes. This study is performed on a large-scale 2000 bus synthetic Texas model by selectively replacing synchronous generators with inverter-based generation resources. This paper also compares the analysis results obtained by the above-mentioned inertia-reduction approach of renewable integration with another approach in which the inertia constant of all synchronous generators is decreased. This paper demonstrates that only reducing the inertia of all synchronous generators in a system does not provide an accurate analysis of the challenges associated with the reduced system inertia caused by renewable integration.

System Inertia, Angular stability, System Inertial↗

Hourly Electricity Demand Profiles for Each County in the Contiguous United States

This dataset provides estimated hourly electricity demand for each county in the contiguous United States from 2016-2023. The demand profiles represent the sum of two components: (1) Weighted averages of reported hourly demand profiles for North American Electric Reliability Corporation balancing authority (BA) regions and subregions, scaled to match annual estimates of county-level retail sales and direct use of electricity and weighted by the estimated percentage of county load served by each BA region or subregion. (2) Weighted averages of modeled hourly, county- and sector-level distributed photovoltaic (DPV) capacity factor profiles, scaled to match annual estimates of on-site consumption of DPV-generated electricity for each county and weighted by the percentage of consumption attributable to each sector Annual county-level retail sales are estimated by aggregating utility-reported sales to the state level and allocating the results to counties according to each county's share of state population. Annual county-level direct use is calculated by aggregating power plant-reported direct use values. Annual county-level on-site consumption of DPV-generated electricity is estimated by aggregating utility-reported net metering data to determine the amount of DPV-generated electricity sold back to the grid for each state, subtracting those values from modeled state-level DPV generation estimates, and allocating the results to counties according to each county's share of statewide modeled DPV generation. The open-source Python code used to develop this dataset is available at "Historical Load Data Repository" link below.

14 SOLAR ENERGY↗

Effects of the U.S. inflation reduction act on SMR economics

The U.S. Inflation Reduction Act (IRA) of 2022 provides a wide array of tax credits and other incentives for low-carbon energy. The technology-neutral clean generation production tax credit (PTC) (Section 45Y of the U.S. Internal Revenue Code) and the technology-neutral investment tax credit (ITC) (Section 48E) lower the net cost of new electricity generation projects with zero or negative greenhouse gas emission rates. We evaluate the impact of the IRA legislation—specifically the PTC and ITC—on the cost-competitiveness of small modular reactors (SMRs). We use the Argonne Low-carbon Energy Analysis Framework (A-LEAF) model to calculate the capacity factor of an SMR with a range of hypothetical variable operating and maintenance (O&M) costs in the Electric Reliability Council of Texas (ERCOT) electricity market. We selected ERCOT for market modeling because of its competitive structure, available data, and extensive use in prior literature. We use a discounted cash flow model to calculate the SMR’s net present value based on the market prices and capacity factors from A-LEAF, hypothetical ranges of capital and variable O&M costs, and other input parameters, with or without the IRA tax credits. We determine the SMR owner’s optimal choice of PTC or ITC for the hypothetical ranges of capital and variable O&M costs. We also evaluate potential shifts in the SMR owner’s optimal choice of PTC or ITC based on historical patterns of nuclear capital cost overruns in the United States. We also assess the sensitivity of our results to longer PTC period and electricity prices from the New England market, which tend to be higher than electricity prices in ERCOT. We find that even with the IRA tax credits, only SMRs with low capital and variable O&M costs would be economically feasible in the low-price ERCOT market scenario modeled. A longer PTC period and higher-price market such as New England, however, would significantly expand the economic feasibility of SMRs in the United States.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Study of blood flow sensing with microwave radiometry

A study and experimental investigation has been performed to determine the feasibility of measuring regional blood flow and volume in man by means of microwave radiometry. An indication was expected of regional blood flow from measurement of surface and subsurface temperatures with a sensitive radiometer. Following theoretical modeling of biological tissue, to determine the optimum operating frequency for adequate sensing depth, a sensitive microwave radiometer was designed for operation at 793 MHz. A temperature sensitivity of of 0.06 K rms was realized in this equipment. Measurements performed on phantom tissue models, consisting of beef fat and lean beefsteak showed that the radiometer was capable of sensing temperatures from a depth between 3.8 and 5.1 cm. Radiometric and thermodynamic temperature measurements were also performed on the hind thighs of large dogs. These showed that the radiometer could sense subsurface temperatures from a depth of, at least, 1.3 cm. Delays caused by externally-generated RF interference, coupled with the lack of reliable blood flow measurement equipment, prevented correlation of radiometer readings with reginal blood flow. For the same reasons, it was not possible to extend the radiometric observations to human subjects.

Porter, R. A.↗

Behind the Meter Storage for Electric Vehicle Charging, Electrochemical and Thermal Energy Storage, and Solar Photovoltaic

In response to the potentially large and irregular demand from EVs, along with changing load profiles from buildings with on-site generation, utilities are evaluating multiple options for managing dynamic loads, including time-of-use pricing, demand charges, battery storage, and curtailment of variable generation. Buildings, as well as commercial, public, and workplace EV charging operations, can use a combination of electrochemical battery storage and thermal energy storage coupled with on-site generation to manage energy costs as well as provide resiliency and reliability for EV charging and building energy loads. We are completing a behind the meter storage analysis that focuses on determining the optimal system designs and energy flows for thermal and electrochemical behind the meter storage with on-site solar photovoltaic (PV) generation enabling electric vehicle charging in various climates, building types, and utility rate structures. In completing this analysis, we have developed a tool that combines existing battery models via the System Advisor Model (SAM) and building modeling software via EnergyPlus into a single interface. This tool allows us to simulate a building with a detailed battery model to properly size the battery, thermal energy storage, and solar PV systems to maximize profit for the system owner. This also allows us to assess how the battery degrades under various supervisory control dispatch algorithms to control charging/discharging; we can also see how thermal energy storage is created and used to complement the battery to reduce thermal loads in the building. With this project, we can analyze new batteries that are designed specifically for energy storage, rather than designed to be extremely energy dense for electric vehicle applications, using battery lifetime models from other national labs and the existing SAM battery model, which has detailed lifetime and degradation parameters. We can also assess novel thermal storage technologies by integrating them into the whole building energy simulation program EnergyPlus. Because the model calls both SAM and EnergyPlus, required inputs need to be compatible for both models. These inputs include, on a high-level, the following: weather files, building and electric vehicle load profiles, electricity rate tariff information, and system cost information for the stationary battery, solar PV, and thermal storage system. The various buildings we are studying for this analysis are retail big-box grocery store, commercial office building, fleet vehicle depot and operations facility, multi-family residential, and electric vehicle charging station. For these different applications, the battery and thermal storage will be dispatched differently, and the various technologies are sized differently to optimize cost.

30 DIRECT ENERGY CONVERSION↗

Improving Thermal Management Strategies for Data Centers: A Physical Testbed Incorporating Small Modular Reactor and Microreactor Technology

This study aims to accelerate the demonstration of various thermal management systems for data centers using nuclear-generated heat to enhance energy and grid reliability. Utilizing mobile containerized and stationary test beds at INL's High Performance Computing (HPC) facility, this project integrates with various nuclear-related energy systems testing facilities. Key components include immersion cooling apparatus, absorption chillers, and adjustable thermal management simulators. Tasks involve acquiring necessary hardware, sensors, and cooling apparatus, engaging with data center industry stakeholders, and providing a testing platform for algorithms, models, tools, and software. The objective is to expedite the deployment of nuclear-powered data centers, thereby improving energy reliability and affordability.

21 - SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLAN↗

Regulatory Considerations Associated with the Expanded Adoption of Distributed Solar

Increased adoption of distributed PV, and other forms of distributed generation, have the potential to affect utility-customer interactions, system costs recovery, and utility revenue streams. If a greater number of electricity customers choose to self-generate, demand for system power will decrease and utility fixed costs will have to be recovered over fewer kilowatt hours of sales. As such, regulators will need to determine the value and cost of additional distributed PV and determine the appropriate allocation of the costs and benefits among consumers. The potential for new business models to emerge also has implications for regulation and rate structures that ensure equitable solutions for all electricity grid users. This report examines regulatory tools and rate designs for addressing emerging issues with the expanded adoption of distributed PV and evaluates the potential effectiveness and viability of these options going forward. It offers the groundwork needed in order for regulators to explore mechanisms and ensure that utilities can collect sufficient revenues to provide reliable electric service, cover fixed costs, and balance cost equity among ratepayers -- while creating a value proposition for customers to adopt distributed PV.

14 SOLAR ENERGY↗

Genetic Optimization of a Tensegrity Structure

Marshall Space Flight Center (MSFC) is charged with developing advanced technologies for space telescopes. The next generation of space optics will be very large and lightweight. Tensegrity structures are built of compressive members (bars), and tensile members (strings). For most materials, the tensile strength of a longitudinal member is larger than its buckling strength; therefore a large stiffness to mass ratio can be achieved by increasing the use of tensile members. Tensegrities are the epitome of lightweight structures, since they take advantage of the larger tensile strength of materials. The compressive members of tensegrity structures are disjoint allowing compact storage of the structure. The structure has the potential to eliminate the requirement for assembly by man in space; it can be deployed by adjustments in its cable tension. A tensegrity structure can be more reliably modeled since none of the individual members experience bending moments. (Members that experience deformation in more than one dimension are much harder to model.) Structures that can be more precisely modeled can be more precisely controlled. Furthermore, an astoundingly wide variety of natural systems, including carbon atoms, water molecules, proteins, viruses, cells, tissues and even human and other living creatures are tensegrity structures. Through the process of evolution, nature continually improves the design of living creatures for the environment they live in. Since tensegrities are nature's structure of choice, it is conceivable that they have other benefits we are unaware of. A. Keane and S. Brown designed a satellite boom truss system with an enhanced vibration performance. They started with a standard truss system, then used a genetic algorithm to alter the design, while optimizing the vibration performance. An improvement of over 20,000% in frequency-averaged energy levels was obtained using this approach. In this report an introduction to tensegrity structures is given, along with a description of how to generate the nodal coordinates and connectivity of a multiple stage cylindrical tensegrity structure. A description of how finite elements can be used to develop a stiffness and mass matrix so that the modes of vibration can be determined from the eigenvalue problem is shown. A brief description of a micro genetic algorithm is then presented.

Jaime R. Taylor↗

Coordinated operation of electricity and natural gas systems from day-ahead to real-time markets

Power systems worldwide are becoming more reliant on energy from natural gas, wind, and solar, posing possible reliability and coordination challenges from the tighter coupling of these infrastructure systems. This paper proposes a framework for the market-based coordination of electricity and natural gas system operations. The proposed framework includes a power system model that accounts for flexibility in the commitment of power plants with short start-up and shut-down times, coupled with a dynamic gas model that simulates when gas cannot be delivered to generators. The capabilities of the framework are illustrated using real-world electric power and gas systems, including scenarios around wind and solar penetrations and the analysis of time-variant, “shaped flow” gas nominations. Our results indicate that coordination between power and gas systems improves total gas delivery and reduces out-of-merit order dispatch in the electricity system, and that shaped flows may reduce unserved gas in systems with high penetrations of wind and solar. Coordination can have mixed effects on carbon-dioxide emissions, with emissions increasing with coordination for current systems during high load weeks but decreasing for systems with high renewable penetrations, particularly during periods of high variability.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Machine learning surrogates for ion energy–angle distributions in thermal and RF plasma sheaths

Ion energy–angle distributions (IEADs) at material surfaces are a critical input for plasma–material interaction (PMI) studies in fusion devices, yet they are computationally expensive to obtain using particle-in-cell (PIC) simulations. In this work, we develop a machine learning surrogate based on a deep deconvolutional neural network (DDeCNN) trained on large databases generated with the hPIC2 code. The surrogate is capable of reconstructing IEADs from sheath parameters for both thermal and radio-frequency (RF) plasmas, including cases with multiple ion species. Across thousands of test cases, the model achieves high accuracy, with over 97 % of predictions classified as good or average based on standard error metrics (MAE, MSE, L2). Even in the more challenging RF and multi-species regimes, the surrogate reliably captures the multi-peak structure of PIC results. Once trained, the surrogate produces IEADs in milliseconds on a common workstation, yielding speedups of six to seven orders of magnitude compared with running a full PIC simulation. This computational gain enables dense parameter scans and direct coupling of IEAD predictions with PMI and erosion models on whole-device scales in fusion-relevant conditions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Phase I Microgrid Cost Study: Data Collection and Analysis of Microgrid Costs in the United States

The U.S. Department of Energy (DOE) Office of Electricity Microgrid Cost Study project is looking at identifying the costs of components, integration and installation of U.S. microgrids and project cost improvements and technical accelerators over the next 5 years and beyond. This information could then be used by the DOE among others, to develop R&D agendas for the development of the next generation microgrids that provide cost effective, reliable and clean energy solutions. Microgrids are gaining in popularity because of their adaptability and flexible expandability, the need for increased electricity reliability, the increased affordability of distributed energy resources (DERs) and grid intelligence devices, goals to reduce greenhouse gas emissions, and other factors. The U.S. Department of Energy commissioned the National Renewable Energy Laboratory to complete a microgrid cost study and develop a microgrid cost model. The goal is to elucidate the variables that have the highest impact on costs as well as potential areas for cost reduction. This study consists of two phases. Phase I comprises the collection and analysis of data from microgrid projects built in the United States and is the subject of this report. In Phase II, NREL will assess current barriers facing the industry and identify potential solutions with help from industry representatives. Microgrid components are classified as follows in the form used to collect cost data from industry representatives for NREL's microgrid cost database: DERs: diesel, natural gas, combined heat and power (CHP), biofuel, solar photovoltaic (PV), wind, and fuel cell and energy storage; microgrid controller: primary, secondary, or tertiary; additional infrastructure: distribution system infrastructure, information technology communications upgrades, metering, etc.; soft costs: engineering, construction, commissioning, and regulatory. The purposes of Phase I are to better determine the contribution of individual components to total project size and to identify cost differences in projects within the same market segment. Phase II will use the results of Phase I to have an initial indication of the costs that might be driving the cost of development the most.

24 POWER TRANSMISSION AND DISTRIBUTION↗