Real-Time Interactive 4D-STEM Phase-Contrast Imaging From Electron Event Representation Data: Less computation with the right representation

The arrival of direct electron detectors (DED) with high frame-rates in the field of scanning transmission electron microscopy has enabled many experimental techniques that require collection of a full diffraction pattern at each scan position, a field which is subsumed under the name four dimensional-scanning transmission electron microscopy (4D-STEM). DED frame rates approaching 100 kHz require data transmission rates and data storage capabilities that exceed commonly available computing infrastructure. Current commercial DEDs allow the user to make compromises in pixel bit depth, detector binning or windowing to reduce the per-frame file size and allow higher frame rates. This change in detector specifications requires decisions to be made before data acquisition that may reduce or lose information that could have been advantageous during data analysis. The 4D Camera, a DED with 87 kHz frame-rate developed at Lawrence Berkeley National Laboratory, reduces the raw data to a linear-index encoded electron event representation (EER). Here we show with experimental data from the 4D Camera that linear-index encoded EER and its direct use in 4D-STEM phase contrast imaging methods enables real-time, interactive phase-contrast from large-area 4D-STEM datasets. Furthermore, we detail the computational complexity advantages of the EER and the necessary computational steps to achieve real-time interactive ptychography and center-of-mass differential phase contrast using commonly available hardware accelerators.

4D-STEM↗

Atomic force microscopy of biological samples

The ability to evaluate structural-functional relationships in real time has allowed scanning probe microscopy (SPM) to assume a prominent role in post genomic biological research. In this mini-review, we highlight the development of imaging and ancillary techniques that have allowed SPM to permeate many key areas of contemporary research. We begin by examining the invention of the scanning tunneling microscope (STM) by Binnig and Rohrer in 1982 and discuss how it served to team biologists with physicists to integrate high-resolution microscopy into biological science. We point to the problems of imaging nonconductive biological samples with the STM and relate how this led to the evolution of the atomic force microscope (AFM) developed by Binnig, Quate, and Gerber, in 1986. Commercialization in the late 1980s established SPM as a powerful research tool in the biological research community. Contact mode AFM imaging was soon complemented by the development of non-contact imaging modes. These non-contact modes eventually became the primary focus for further new applications including the development of fast scanning methods. The extreme sensitivity of the AFM cantilever was recognized and has been developed into applications for measuring forces required for indenting biological surfaces and breaking bonds between biomolecules. Further functional augmentation to the cantilever tip allowed development of new and emerging techniques including scanning ion-conductance microscopy (SICM), scanning electrochemical microscope (SECM), Kelvin force microscopy (KFM) and scanning near field ultrasonic holography (SNFUH).

59 BASIC BIOLOGICAL SCIENCES↗

High fidelity ultrasound imaging of concrete structures

As plans are made to extend licenses for the aging fleet of commercial nuclear power plants for periods of sixty years and beyond, research into the long-term integrity of their concrete structures has increased. Ultrasound tomography is a useful tool for nondestructive evaluation of these concrete structures. Typically, pulse-echo measurements are made over a large surface and are processed using a reconstruction algorithm, producing a 3D image of the structure that highlights embedded defects. These measurements are processed using a delay-and-sum algorithm such as the synthetic aperture focusing technique (SAFT). Oak Ridge National Laboratory is developing novel ultrasound model-based image reconstruction (U-MBIR) algorithms to improve the imaging capability of pulse-echo ultrasound array imagers. U-MBIR is an inversion technique that reconstructs the sample under test from the ultrasound measurements by formulating and solving a mathematical optimization problem using two sets of terms: one set ensures that the reconstruction matches measured data based on a model for the physics of beam propagation with the noise in the detector, and another set ensures that the reconstruction has certain properties based on a model for the object being scanned. This paper compares three techniques: SAFT, frequency-banded SAFT (FB-SAFT), and U-MBIR. The U-MBIR method produces higher quality images of the underlying concrete structures compared to the images produced using SAFT and FB-SAFT from the same set of measurements. This paper also illustrates the detection of various defects with higher confidence due to the lower noise and artifact-free U-MBIR images.

Ezell, N Dianne↗

Monitoring damage growth in titanium matrix composites using acoustic emission

The application of the acoustic emission (AE) technique to locate and monitor damage growth in titanium matrix composites (TMC) was investigated. Damage growth was studied using several optical techniques including a long focal length, high magnification microscope system with image acquisition capabilities. Fracture surface examinations were conducted using a scanning electron microscope (SEM). The AE technique was used to locate damage based on the arrival times of AE events between two sensors. Using model specimens exhibiting a dominant failure mechanism, correlations were established between the observed damage growth mechanisms and the AE results in terms of the events amplitude. These correlations were used to monitor the damage growth process in laminates exhibiting multiple modes of damage. Results revealed that the AE technique is a viable and effective tool to monitor damage growth in TMC.

Bakuckas, J. G., Jr.↗

Dosimetry And Its Enhancement Using Gold Nanoparticles In Synchrotron Based Microbeam And Stereotactic Radiosurgery

Research into the areas of synchrotron generated microbeam radiotherapy (MRT) and stereotactic radiosurgery is increasing. Such MRT techniques are showing potential of tackling some of the more difficult radiotherapy cases such as certain type of brain tumours. Two challenging aspects of these techniques are addressed in this investigation; the difficulty of dose determination and the delivery of the treatments at lower dose levels. In this research polymer gels were used as phantoms and dosimeters and cells were used to confirm outcomes. Normoxic polyacrylamide gels (nPAG) were tested as potential dosimeters for microbeam dosimetry. Following irradiation using microbeam and minibeam radiation from the BL28BU beam-line at Spring-8, Japan, the nPAG were scanned using a Raman spectroscopy technique. Dose enhancement caused by the inclusion of the gold nanoparticles (AuNPs) in the target was investigated using both cells and polymer gels. The use of AuNP could potentially reduce the dose required for the delivery of MRT. In this study it was shown that using endothelial cells with AuNPs, the minimal dose for clear cell killing along the beam line was reduced to 10 Gy. Both studies cell and gel studies indicates significant dose enhancement caused by the gold atoms in the target.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Application of Optical Measurement Techniques During Fabrication and Testing of Liquid Rocket Nozzles

This paper presents a series of optical measurement techniques that were developed for use during large-scale fabrication and testing of nozzle components. A thorough understanding of hardware throughout the fabrication cycle and hotfire testing is critical to meet component design intent. Regeneratively cooled nozzles and associated tooling require tight control of tolerances during the fabrication process to ensure optimal performance. Additionally, changes in geometry during testing can affect performance of the nozzle and mating components. Structured light scanning and digital image correlation techniques were used to collect data during the fabrication and test of nozzles, in addition to other engine components. This data was used to analyze deformations data during machining, heat treatment, assembly and testing operations. A series of feasibility experiments were conducted for these techniques that led to use on full scale nozzles during the J-2X upper stage engine program in addition to other engine development programs. This paper discusses the methods and results of these measurement techniques throughout the nozzle life cycle and application to other components.

Gradl, Paul R.↗

Nanomanipulation and nanofabrication with multi-probe STM: From individual atoms to nanowires

The wide variety of nanoscale structures and devices demands novel tools for handling, assembly, and fabrication at nanoscopic positioning precision. The manipulation tools should allow for in situ characterization and testing of fundamental building blocks, such as nanotubes and nanowires, as they are built into functional devices. In this paper, a bottom-up technique for nanomanipulation and nanofabrication is reported by using a 4-probe scanning tunneling microscope (STM) combined with a scanning electron microscope (SEM). The applications of this technique are demonstrated in a variety of nanosystems, from manipulating individual atoms to bending, cutting, breaking carbon nanofibers, and constructing nanodevices for electrical characterizations. The combination of the wide field of view of SEM, the atomic position resolution of STM, and the flexibility of multiple scanning probes is expected to be a valuable tool for rapid prototyping in the nanoscience and nanotechnology.

Qin, Shengyong↗

Precession electron diffraction for SiC grain boundary characterization in unirradiated TRISO fuel

Precession electron diffraction (PED), a transmission electron microscopy-based technique, has been evaluated for the suitability for evaluating grain boundary character in the SiC layer of tristructural isotropic (TRISO) fuel. Although the ultimate goal is to determine the grain boundary characteristics of fission product containing grain boundaries of neutron irradiated SiC, our work reports the effect of transmission electron microscope (TEM) lamella thickness on quality of data and establishes a baseline comparison on grain boundary characteristics determined previously using a conventional EBSD scanning electron microscope (SEM) based technique. In general, it was determined that the lamella thickness produced using the standard FIB fabrication process, is sufficient to provide reliable PED measurements with thicker lamellae (~120 nm) produce higher quality orientation data. Analysis of grain boundary character from the TEM-based PED data showed a much lower fraction of low angle grain boundaries compared to SEM-based EBSD data from the SiC layer of the same TRISO-coated particle as well as a SiC layer deposited at a slightly lower temperature. The fractions of high angle and CSL-related grain boundaries determined by PED are similar to those found using SEM-based EBSD. Since the grain size of the SiC layer of TRSIO fuel can be as small as 250 nm [12], depending on the fabrication parameters, and grain boundary fission product precipitates can be nano-sized, the TEM-based PED orientation data collection method is preferred to determine an accurate representation of the relative fractions of low angle, high angle and CSL-related grain boundaries. It was concluded that although the resolution of the PED data is better by more than an order of magnitude, data acquisition times may be significantly longer or the number of areas analyzed significantly larger than the SEM-based method to obtain a statistically relevant distribution. Also, grain size could be accurately determined but significantly larger analysis areas than those used in this study would be required.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Probing Light Atoms at Subnanometer Resolution: Realization of Scanning Transmission Electron Microscope Holography

Atomic resolution imaging of light elements in electron-transparent materials has long been a challenge. Biomolecular materials, for example, are rapidly altered by incident electrons. We demonstrate a scanning transmission electron microscopy (STEM) technique, called STEM holography, capable of efficient structural analysis of beam-sensitive nanomaterials. STEM holography measures the absolute phase and amplitude of electrons passed through a specimen via interference with a vacuum reference wave. We use an amplitude-dividing nanofabricated grating to prepare multiple beams focused at the sample. We configure the postspecimen microscope imaging system to overlap the beams, forming an interference pattern. We record and analyze the pattern at each 2D-raster-scan-position, reconstructing the complex object wave. As a demonstration, we image gold nanoparticles on an amorphous carbon substrate at 2.4 Å resolution. In conclusion STEM holography offers higher contrast of the carbon while maintaining gold atomic lattice resolution compared to high angle annular dark field STEM.

4D-STEM↗

TU-CD-304-04: Scanning Field Total Body Irradiation Using Dynamic Arc with Variable Dose Rate and Gantry Speed

Purpose: Enable a scanning field total body irradiation (TBI) technique, using dynamic arcs, which is biologically equivalent to a moving couch TBI. Methods: Patient is treated slightly above the floor and the treatment field scans across the patient by a moving gantry. MLC positions change during gantry motion to keep same field opening at the level of the treatment plane (170 cm). This is done to mimic the same geometry as the moving couch TBI technique which has been used in our institution for over 10 years. The dose rate and the gantry speed are determined considering a constant speed of the moving field, variations in SSD and slanted depths resulting from oblique gantry angles. An Eclipse (Varian) planning system is commissioned to accommodate the extended SSD. The dosimetric foundations of the technique have been thoroughly investigated using phantom measurements. Results: Dose uniformity better than 2% across 180 cm length at 10cm depth is achieved by moving the gantry from −55 to +55 deg. Treatment range can be extended by increasing gantry range. No device such as a gravity-oriented compensator is needed to achieve a uniform dose. It is feasible to modify the dose distribution by adjusting the dose rate at each gantry angle to compensate for body thickness differences. Total treatment time for 2 Gy AP/PA fields is 40–50 minutes excluding patient set up time, at the machine dose rate of 100 MU/min. Conclusion: This novel yet transportable moving field technique enables TBI treatment in a small treatment room with less program development preparation than other techniques. Treatment length can be extended per need, and. MLC-based thickness compensation and partial lung blocking are also possible.

60 APPLIED LIFE SCIENCES↗

Investigation of high temperature corrosion behavior on 304L austenite stainless steel in corrosive environments

In this work, 304L stainless steel samples were exposed at 700 °C for 10hrs in different corrosive environments; dry oxygen, molten salt, and molten salt + dry oxygen. The corrosion behavior of samples was analyzed using weight change measurement technique, optical microscope (OM) and Scanning Electron Microscope (SEM) equipped with Energy Dispersive X-ray (EDX). The existence phases of corroded sample were determined using X-ray Diffraction (XRD). The lowest corrosion rate was recorded in dry oxygen while the highest was in molten salt + dry oxygen environments with the value of 0.0062 mg/cm{sup 2} and −13.5225 mg/cm{sup 2} respectively. The surface morphology of sample in presence of salt mixture showed scale spallation. Oxide scales of Fe{sub 3}O{sub 4}, Fe{sub 2}O{sub 3} were the main phases developed and detected by XRD technique. Cr{sub 2}O{sub 3} was not developed in every sample as protective layers but chromate-rich oxide was developed. The cross-section analysis found the oxide scales were in porous, thick and non-adherent that would not an effective barrier to prevent from further degradation of alloy. EDX analysis also showed the Cr-element was low compared to Fe-element at the oxide scale region.

36 MATERIALS SCIENCE↗

Quantitative Scanning Laue Diffraction Microscopy: Application to the Study of 3D Printed Nickel-Based Superalloys

Progress in computing speed and algorithm efficiency together with advances in area detector and X-ray optics technologies have transformed the technique of synchrotron radiation-based scanning Laue X-ray microdiffraction. It has now evolved into a near real-time quantitative imaging tool for material structure and deformation at the micrometer and nanometer scales. We will review the achievements of this technique at the Advanced Light Source (Berkeley, CA, USA), and demonstrate its application in the thorough microstructural investigations of laser-assisted 3D printed nickel-based superalloys.

36 MATERIALS SCIENCE↗

Aperture-coupled thin-membrane microstrip array antenna for beam scanning application

A microstrip array using aperture-slot-coupling technique with very thin membranes has been developed at the L-band frequency for beam scanning application. This technology-demonstration array with 4 x 2 elements achieved a relatively wide bandwidth of 100 MHz (8%) and +/-45(deg) beam scan. Very narrow coupling slots were used with each having an aspect ratio of 160 (conventional slot aspect ratio is between 10 to 30) for coupling through very thin membrane (0.05mm thickness). This thin-membrane aperture-coupling technique allows the array antenna elements to be more easily integrated with transmit/receive amplifier (T/R) and phase shifter modules. This paper addresses only the radiator portion of the array. The array and active components will be presented in a separate pape.

array antenna↗

Mitigate Stress Corrosion Cracking (SCC) in High-strength Al Castings (CRADA 508)

Development of high strength, corrosion resistant, aluminum alloys is important to a number of industries, including automotive, aerospace, power, etc. Understanding how processing methods such as casting, chemistry, additives and recycle content affect an alloy’s microstructure and performance in real world environments is crucial to their implementation. One major concern is how the repeated exposure to saline solutions can be detrimental to the structural integrity of aluminum alloy components. This study was undertaken as a collaboration between Eck Industries and PNNL to investigate the stress corrosion cracking (SCC) and corrosion behavior of aluminum alloys. This work examines the SCC response of three different materials set. First is cast A206 Al alloy produced by three different casting techniques (i.e., permanent mold, and sand casting with and without chill) and with or without nano forming additives as potential grain refiners. The second materials set comprises Al alloy tubes extruded by PNNL’s ShAPE process and produced using raw material with three different ratios of twitch and pre-consumer Al 6061 scrap. Finally, the third materials set comprises two Al-Si-Mg-Fe alloys with controlled Si% and Fe% to mimic recycle grade Al alloys. The corrosion behavior of these materials was characterized using SCC testing and scanning electrochemical cell microscopy (SECCM) technique; mechanical behavior was characterized using tensile testing, and microstructure was characterized using optical and electron microscopy techniques. Of the A206 Al alloys, the samples with nano forming additives performed poorly compared to those without. The best SCC performance (i.e. least degradation in mechanical properties) was demonstrated by A206 alloy sand cast with chill while the permanent mold sample showed the worst SCC performance. The SECCM was performed on A206 alloy sand cast with chill to understand the effect of microstructure and determine the location-dependent corrosion properties on grain boundaries (GB) and inside grains (IG) on the sample. The corrosion potential and current measured on GB and IG at various points on the sample established that the GB locations are more cathodic and corrosive than the IG locations. Further work needs to be conducted to investigate the mechanisms behind the observed dependence of SCC on casting technique and nano forming additives. Among the ShAPE extruded tubes, SECCM data suggests the decreasing order of tendency to corrode as follows: 100% twitch > 75% twitch > 50% twitch. Finally, both variants of the Al-Si-Mg-Fe alloys showed a large volume fraction of Fe- and Si-containing intermetallics and additional work is needed to discern differences in their respective corrosion responses. In summary, correlating local electrochemical behavior (e.g. via SECCM) with micro/nanostructure, in conjunction with bulk mechanical behavior, can help identify the right fabrication method and alloy chemistry to minimize SCC issues in Al alloys.

36 MATERIALS SCIENCE↗

Microstructural Characterization of Irradiated U{sub 0.17}ZrH{sub 1.6} Using Ultrasonic Techniques

In recent years, there has been an increased level of effort to understand the changes in microstructure that occur due to irradiation of nuclear fuel. The primary driver for this increased effort is the potential for designing new fuels that are safer and more reliable, in turn enabling new and improved reactor technologies. Much of the data on microstructural change in irradiated fuels is generated through a host of post irradiation examination techniques such as optical microscopy (OM), scanning electron microscopy (SEM), and transmission electron microscopy (TEM) to determine grain structure, porosity, crack geometry, etc. in irradiated fuels. Such 'traditional' examination techniques were recently used to characterize a novel new fuel consisting of U{sub 0.17}ZrH{sub 1.6} pellets bonded to zircaloy-2 cladded with lead-bismuth eutectic before and after irradiation. In addition to the conventional suite of post-irradiation examination tools, several nondestructive interrogation techniques exist which bring the potential for in-situ assessment of microstructural changes. One such method, ultrasonic examination, was tested on each of the samples. This paper describes the results of this examination. Ultrasonic measurements have a long and successful history of use for nondestructive materials characterization, including nondestructive evaluation (NDE) of degradation and damage, microstructure characterization, and measurement of physical parameters for process control. Ultrasonic NDE is critical to the nuclear power industry's in-service inspection program for maintaining pressure boundary integrity, and is being actively investigated for PIE of fuels. Ultrasonic measurements, typically performed at 10 MHz or higher, performed post irradiation show that fuel microstructural parameters, such as porosity and grain size, can be correlated to ultrasonic velocity. The objective of this examination was to assess the feasibility of using ultrasonic measurements on irradiated fuel to determine sensitivity to microstructural changes.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Solar cell anomaly detection method and apparatus

A method is provided for detecting cracks and other imperfections in a solar cell, which includes scanning a narrow light beam back and forth across the cell in a raster pattern, while monitoring the electrical output of the cell to find locations where the electrical output varies significantly. The electrical output can be monitored on a television type screen containing a raster pattern with each point on the screen corresponding to a point on the solar cell surface, and with the brightness of each point on the screen corresponding to the electrical output from the cell which was produced when the light beam was at the corresponding point on the cell. The technique can be utilized to scan a large array of interconnected solar cells, to determine which ones are defective.

Miller, Emmett L.↗

Two-step controllable electrochemical etching of tungsten scanning probe microscopy tips

Dynamic electrochemical etching technique is optimized to produce tungsten tips with controllable shape and radius of curvature of less than 10 nm. Nascent features such as 'dynamic electrochemical etching' and reverse biasing after 'drop-off' are utilized, and 'two-step dynamic electrochemical etching' is introduced to produce extremely sharp tips with controllable aspect ratio. Electronic current shut-off time for conventional dc 'drop-off' technique is reduced to {approx}36 ns using high speed analog electronics. Undesirable variability in tip shape, which is innate to static dc electrochemical etching, is mitigated with novel 'dynamic electrochemical etching.' Overall, we present a facile and robust approach, whereby using a novel etchant level adjustment mechanism, 30 Degree-Sign variability in cone angle and 1.5 mm controllability in cone length were achieved, while routinely producing ultra-sharp probes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Microstructural Characterization of Irradiated U0.7ZrH1.6 Using Ultrasonic Techniques

In recent years, there has been an increased level of effort to understand the changes in microstructure that occur due to irradiation of nuclear fuel. The primary driver for this increased effort is the potential for designing new fuels that are safer and more reliable, in turn enabling new and improved reactor technologies. Much of the data on microstructural change in irradiated fuels is generated through a host of post irradiation examination techniques such as optical microscopy (OM), scanning electron microscopy (SEM), and transmission electron microscopy (TEM) to determine grain structure, porosity, crack geometry, etc. in irradiated fuels. Such “traditional” examination techniques were recently used to characterize a novel new fuel consisting of U0.17ZrH1.6 pellets bonded to zircaloy-2 cladded with lead-bismuth eutectic before and after irradiation. However, alternative methods such as ultrasonic inspection can provide an opportunity for nondestructively assessing microstructure in both in-pile and post-irradiation examinations. In this paper, we briefly describe initial results of ultrasonic examination of the U0.17ZrH1.6 pellets (unirradiated and irradiated), in a post-irradiation examination study. Data indicate some correlation with microstructural changes due to irradiation; however, it is not clear what the specific microstructural changes are that are influencing the ultrasonic measurements. Interestingly, specimens with nominally identical burnup show differences in ultrasonic signatures, indicating apparent microstructural differences between these specimens. A summary of the experimental study, preliminary data and findings are presented in this short paper. Additional details of the analysis will be included in the presentation.

Microstructure evaluation↗