Search NASA⌕ Search

SEARCH · Search NASA

Results for “Sensitivity Matrix”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,189 records · Page 66

SU-E-T-270: Quality Control of Source Strength and Indexer Length in HDR Brachytherapy Using Sun Nuclear Mapcheck2

Purpose: The goal of this work was to evaluate Sun Nuclear MapCheck2 capability for quantitative determination of both HDR source strength and position. Predictive power of Mapcheck2 dose matrix, originated by a microSelectron-v2 source from 22mm distance, was investigated. Methods: A Mick MultiDoc phantom with the 1400mm indexer length mark aligned over MapCheck2 central detector plus two additional 5cm plastic slabs were used as a composite phantom. Dose readings were transformed by applying published source anisotropy corrections and experimentally established radial dose and relative sensitivity factors. Angular dependence was not considered. Only readings from diodes located 2cm around the central detector were evaluated. The reproducibility of a fit between transformed dose readings and the ratio of virtual source strength and the square of source-detector distance was investigated. Four parameters were considered in the model: virtual source strength, lateral, longitudinal and vertical source positions. Final source strength calibration factor was calculated from the ratio of reference measurements and results from the fit. Results: Original lateral and longitudinal source position estimations had systematic errors of 0.39mm and 0.75mm. After subtracting these errors, both source positions were predicted with a standard deviation of 0.15mm. Results for vertical positions were reproducible with a standard deviation of 0.05mm. The difference between calculated and reference source strengths from 34 independent measurement setups had a standard deviation of 0.3%. The coefficient of determination for the linear regression between known indexer lengths and results from the fit in the range 1400mm ± 5mm was 0.985. Conclusions: ource strength can be estimated with MapCheck2 at appropriate accuracy levels for quality control. Verification of indexer length with present implementation is more accurate than visual alternatives. Results can be improved by designing a coupling catheter phantom and refining relative diode calibration. Diode angular dependence in MapCheck2 does not play significant role.

07 ISOTOPE AND RADIATION SOURCES↗

Nonuniform thermal environmental effects on space truss structural reliability

A three-bay, space, cantilever truss is probabilistically evaluated to quantify the range of uncertainties of buckling loads and member forces due to nonuniform thermal loads, applied loads and moments (mechanical loads), and combination of both. The truss members are assumed to be made from (1) aluminum tubes or (2) high modulus graphite-fiber/intermediate modulus epoxy-matrix composite tubes. Cumulative distribution function results show that certain combinations of thermal loads with mechanical loads reduce the probabilistic buckling loads and increase the magnitude of the member axial forces for aluminum truss. However, the reverse is true for composite truss due to very low coefficient of thermal expansion and higher stiffness of the composite. Finally, the sensitivities associated with the uncertainties in the structural, material, and load variables (primitive variables) are investigated. They show that buckling loads and member axial forces are most sensitive to the uncertainties in spacial (geometry) variables.

Pai, Shantaram S.↗

The Effect of Gravity Fields on Cellular Gene Expression

Early theoretical analysis predicted that microgravity effects on the isolated cell would be minuscule at the subcellular level; however, these speculations have not proven true in the real world. Astronauts experience a significant bone and muscle loss in as little as 2 weeks of spaceflight and changes are seen at the cellular level soon after exposure to microgravity. Changes in biological systems may be primarily due to the lack of gravity and the resulting loss of mechanical stress on tissues and cells. Recent ground and flight studies examining the effects of gravity or mechanical stress on cells demonstrate marked changes in gene expression when relatively small changes in mechanical forces or gravity fields were made. Several immediate early genes (IEG) like c-fos and c-myc are induced by mechanical stimulation within minutes. In contrast, several investigators report that the absence of mechanical forces during space flight result in decreased sera response element (SRE) activity and attenuation of expression of IEGs such as c-fos, c-jun and cox-2 mRNAs. Clearly, these early changes in gene expression may have long term consequences on mechanically sensitive cells. In our early studies on STS-56, we reported four major changes in the osteoblast; 1) prostaglandin synthesis in flight, 2) changes in cellular morphology, 3) altered actin cytoskeleton and 4) reduced osteoblast growth after four days exposure to microgravity. Initially, it was believed that changes in fibronectin (FN) RNA, FN protein synthesis or subsequent FN matrix formation might account for the changes in cytoskeleton and/ or reduction of growth. However our recent studies on Biorack (STS-76, STS-81 and STS-84), using ground and in-flight 1-G controls, demonstrated that fibronectin synthesis and matrix formation were normal in microgravity. In addition, in our most recent Biorack paper, our laboratory has documented that relative protein synthesis and mRNA synthesis are not changed after 24 hours exposure to microgravity. We did, however, find significant changes in osteoblast gene expression of IEGs, c-fos and cox-2 in microgravity exposure as compared to ground and in-flight 1-G controls. Subsequent ground studies suggest that the molecular mechanism underlying these changes may involve prostaglandin c-AMP receptors (EPs) and/or subsequent alteration of intracellular signaling in the absence of gravity.

Hughes-Fulford, Millie↗

Effects of Microstructural Variability on Thermo-Mechanical Properties of a Woven Ceramic Matrix Composite

The objectives of this paper include identifying important architectural parameters that describe the SiC/SiC five-harness satin weave composite and characterizing the statistical distributions and correlations of those parameters from photomicrographs of various cross sections. In addition, realistic artificial cross sections of a 2D representative volume element (RVE) are generated reflecting the variability found in the photomicrographs, which are used to determine the effects of architectural variability on the thermo-mechanical properties. Lastly, preliminary information is obtained on the sensitivity of thermo-mechanical properties to architectural variations. Finite element analysis is used in combination with a response surface and it is shown that the present method is effective in determining the effects of architectural variability on thermo-mechanical properties.

Goldsmith, Marlana B.↗

Modeling Single Well Injection-Withdrawal (SWIW) Tests for Characterization of Complex Fracture-Matrix Systems

The ability to reliably predict flow and transport in fractured porous rock is an essential condition for performance evaluation of geologic (underground) nuclear waste repositories. In this report, a suite of programs (TRIPOLY code) for calculating and analyzing flow and transport in two-dimensional fracture-matrix systems is used to model single-well injection-withdrawal (SWIW) tracer tests. The SWIW test, a tracer test using one well, is proposed as a useful means of collecting data for site characterization, as well as estimating parameters relevant to tracer diffusion and sorption. After some specific code adaptations, we numerically generated a complex fracture-matrix system for computation of steady-state flow and tracer advection and dispersion in the fracture network, along with solute exchange processes between the fractures and the porous matrix.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Magnetic, dielectric, magnetoelectric, and microstructural studies demonstrating improved magnetoelectric sensitivity in three-phase BaTiO{sub 3}-CoFe{sub 2}O{sub 4}-poly(vinylidene-fluoride) composite

A three-phase BaTiO{sub 3}-CoFe{sub 2}O{sub 4}-poly(vinylidene-fluoride) (BT-CF-PVDF) particulate composite showing a maximum magnetoelectric voltage coefficient alpha{sub E33}approx26 mV/cm Oe, at a small applied magnetic field H{sub DC}=263 Oe, has been demonstrated in this work. Large magnetoelectric response in this composite (particulate BT-CF embedded in PVDF matrix) is possibly a result of the effective mechanical interaction between CF and BT through the PVDF matrix. Processing temperatures for composite preparation are low, ensuring no chemical reaction or interdiffusion between the atoms of piezoelectric and magnetostrictive phases, leading to large value of magnetoelectric voltage coefficient. Detailed measurements of dielectric, magnetic, and static magnetoelectric data are reported. Peak in the dielectric spectrum is shown to correlate with the buildup of magnetization in the composite. Although the M-H loop gives M{sub s}, M{sub r}, and H{sub c} (=37.2 emu/g, 16.4 emu/g, and 830 Oe, respectively) in accordance with the expected values (wt % of CF in the composite is 52.5%), the overall magnetic behavior of the composite is identified as 'spin glass'.

36 MATERIALS SCIENCE↗

Measurement of the Electroweak Single Top Quark Production Cross Section and the CKM Matrix Element $|V_{tb}|$ at CDF Run II

The establishment of the electroweak single top quark production at CDF is experimentally challenging. The small single top signal hidden under large uncertain background processes makes it necessary an excellent understanding of the detector and a detailed study of the processes involved. Moreover, simple counting experiments are not sufficient to extract enough information from the candidate event sample and multivariate analysis techniques are crucial to distinguish signal from background. This thesis presents the world’s most sensitive individual search, together with CDF’s Neural Network analysis, for the combined s- and t-channel single top production. This analysis uses a dataset that corresponds to an integrated luminosity of 3.2fb -1 , and is based on a Boosted Decision Tree method that combines information from several input variables to construct a final powerful discriminant, reaching a sensitivity to the combined single top quark production equivalent to 5.2σ. The measured combined single top quark production cross section is 2.1 +0.7 -0.6 pb assuming a top quark mass of 175 GeV/c 2 . The probability that this result comes from a background-only fluctuation (p-value) is 0.0002, which corresponds to 3.5σ.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Shotgun Proteomics Identifies Proteins Specific for Acute Renal Transplant Rejection

Acute rejection (AR) remains the primary risk factor for renal transplant outcome; development of non-invasive diagnostic biomarkers for AR is an unmet need. We used shotgun proteomics using LC-MS/MS and ELISA to analyze a set of 92 urine samples, from patients with AR, stable grafts (STA), proteinuria (NS), and healthy controls (HC). A total of 1446 urinary proteins were identified along with a number of NS specific, renal transplantation specific and AR specific proteins. Relative abundance of identified urinary proteins was measured by protein-level spectral counts adopting a weighted fold-change statistic, assigning increased weight for more frequently observed proteins. We have identified alterations in a number of specific urinary proteins in AR, primarily relating to MHC antigens, the complement cascade and extra-cellular matrix proteins. A subset of proteins (UMOD, SERPINF1 and CD44), have been further cross-validated by ELISA in an independent set of urine samples, for significant differences in the abundance of these urinary proteins in AR. This label-free, semi-quantitative approach for sampling the urinary proteome in normal and disease states provides a robust and sensitive method for detection of urinary proteins for serial, non-invasive clinical monitoring for graft rejection after

59 BASIC BIOLOGICAL SCIENCES↗

Mg vacancy and impurity-limited MgO single crystal thermal conductivity

Magnesium oxide (MgO) exhibits one of the highest thermal conductivities among oxides and is widely used as a dielectric material and substrate in semiconductor devices, in refractory applications, and as a promising filler in thermal interface materials for electronics. Its high thermal conductivity may be sensitive to impurity and defects, yet this influence is still uncertain. Here, in this study, the impact of the common impurities, i.e., Al, Ca, Ti, V, Fe, Si, B, Nb, Zr, Na, and K, as well as Mg and O vacancies on phonon scattering and thermal conductivity of MgO is studied using a fully first-principles T-matrix framework. It is found that B, Nb, and Zr impurities, along with Mg vacancies, lead to exceptionally strong reductions in thermal conductivity. By contrast, O vacancies and other impurities have modest to minimal impacts. Leveraging the T-matrix results, we reassess the perturbative, mass-only formalism whose use is pervasive in the literature and show that neglecting bond disorder does not necessarily lead to underestimation: for all transition-metal impurities studied, bond perturbations partially cancel mass disorder, causing the traditional perturbative model to overestimate scattering. We propose a simple modified perturbative expression that incorporates both mass and bond disorder and closely reproduces the T-matrix trends. Our predicted low-temperature trends by including phonon-impurity and phonon-boundary scattering match reasonably well with experiments. This work provides an in-depth study of impurity- and vacancy-limited thermal conductivity of MgO and suggests that reported “high-purity” MgO values have likely not yet reached the intrinsic upper limit, which may be substantially higher.

36 - MATERIALS SCIENCE↗

The role of osteopontin in D-galactosamine-induced liver injury in genetically obese mice

Various epidemiological studies have shown that obesity increases the risk of liver disease, but the precise mechanisms through which this occurs are poorly understood. In the present study, we hypothesized that osteopontin (OPN), an extracellular matrix and proinflammatory cytokine, has an important role in making obese mice more susceptible to inflammatory liver injury. After exposure of genetically obese ob/ob and db/db mice to a single dose of D-galactosamine (GalN), the plasma liver enzyme levels, histology and expression levels of cytokines and OPN were evaluated. The ob/ob and db/db mice, which were more sensitive to GalN-induced inflammatory liver injury compared with wild-type mice, had significantly higher plasma and hepatic OPN expression levels. Increased OPN expression was mainly found in hepatocytes and inflammatory cells and was correlated with markedly up-regulated interleukin (IL)-12 and IL-18 levels. Furthermore, pretreatment with a neutralizing OPN (nOPN) antibody attenuated the GalN-induced inflammatory liver injury in ob/ob and db/db mice, which was accompanied by significantly reduced macrophages recruitment and IL-12 and IL-18 productions. Taken together, these results suggest that up-regulated OPN expression is a contributing factor to increased susceptibility of genetically obese mice to GalN-induced liver injury by promoting inflammation and modulating immune response.

60 APPLIED LIFE SCIENCES↗

Observations on the deformation of metal microspheres in shock-driven polymer flows

We report that solid particles can be fragmented by a fast-moving fluid if their velocity difference is great enough, such as during the atmospheric entry of meteoroids or the shock compression of engineered particulate composites. The extent of particle deformation and breakup in such systems is poorly understood because the necessary extreme conditions make observation difficult and data scarce. To meet this need, experiments combining ultrafast synchrotron-based radiography with plate impact loading were performed at the dynamic compression sector at the advanced photon source. Metal microspheres of several densities and strengths (Au, Ta, and W) were placed inside a polymer matrix. A planar shock wave was then produced in the polymer by the impact of a gun-launched flyer plate. X-ray images of the resulting flow were collected at ~150ns intervals. These images document the progression of particle deformation across a range of flow conditions and particle materials. They show that the extent of deformation is sensitive to the ratio of drag stress to particle strength. The deforming particle's shape is determined by the initial shock–particle interaction, fluid stagnation pressure, and vorticity, each acting on its own timescale. A set of scaling relationships is presented to capture these observations and enable comparison with prior hydrodynamic data. The result is a framework for predicting the conditions under which strong particles are severely deformed by a shock-driven flow.

36 MATERIALS SCIENCE↗

Performance of High Stopping Power Bismuth-Loaded Plastic Scintillators for Radiation Portal Monitors

Plastic scintillators are widely used in radiation portal monitors because of their low cost and availability in large sizes. However, due to their low density and low effective atomic number (Z), they offer low intrinsic efficiency and little spectroscopic information. The addition of high-Z constituents to these plastics can greatly increase both their total stopping power and the amount of photoelectric absorption, leading to full-energy deposition and thus useful gamma spectra. Herein, we present the performance of the latest formulation of Bi-loaded plastic scintillators showing their useful spectroscopic information up to relatively high energy (~1 MeV) due to their high stopping power compared to the current commercially available plastics. These Bi-loaded plastics use 20 weight percent (wt%) Bi-pivalate (8 wt% elemental Bi) dissolved in polyvinyltoluene (PVT) matrix and conventional fast fluors (~10 ns decay time). These Bi-loaded plastics achieve up to approximately 6000 photons/MeV and have been produced in sizes up to 17 in 3 . The performance of these Bi-loaded plastics is also demonstrated in the existing portal monitor hardware (Rapiscan Model TSA Trainer 770) showing the possibility to provide improved sensitivity as a drop-in replacement with continued scale-up.

42 ENGINEERING↗

Analysis of useful ion yield for Si in GaN by secondary ion mass spectrometry

The optimum detection levels that can be achieved by a secondary ion mass spectrometer are dependent on how efficiently a particular species of interest can be ionized and detected. One can determine in advance whether the analysis of a particular ion in the sample is possible, if the useful ion yield is known. The useful ion yield depends on the element, instrument transmission, the analytical conditions, the sample matrix, etc. The value of the useful ion yield for a species can diverge from one instrument type to another due to its different transmission and ionization probabilities. However, the same tendencies in the results may be expected for all types of instruments. In this paper, the authors present a quantitative secondary ion mass spectrometry analysis of the useful ion yield for the silicon dopant species in a gallium nitride matrix grown by metal organic chemical vapor deposition. Positively ionized cesium was used as the primary ion beam, and its energy was varied in the range from 0.5 to 5 kV. A quadrupole mass analyzer was utilized to collect secondary ion species of interest. The analysis results can be used to determine the primary beam energies for optimal Si sensitivity.

Senevirathna, M. K. Indika (ORCID:0000000243575029↗

Unifying soil organic matter formation and persistence frameworks: the MEMS model

Soil organic matter (SOM) dynamics in ecosystem-scale biogeochemical models have traditionally been simulated as immeasurable fluxes between conceptually defined pools. This greatly limits how empirical data can be used to improve model performance and reduce the uncertainty associated with their predictions of carbon (C) cycling. Recent advances in our understanding of the biogeochemical processes that govern SOM formation and persistence demand a new mathematical model with a structure built around key mechanisms and biogeochemically relevant pools. Here, we present one approach that aims to address this need. Our new model (MEMS v1.0) is developed from the Microbial Efficiency-Matrix Stabilization framework, which emphasizes the importance of linking the chemistry of organic matter inputs with efficiency of microbial processing and ultimately with the soil mineral matrix, when studying SOM formation and stabilization. Building on this framework, MEMS v1.0 is also capable of simulating the concept of C saturation and represents decomposition processes and mechanisms of physico-chemical stabilization to define SOM formation into four primary fractions. After describing the model in detail, we optimize four key parameters identified through a variance-based sensitivity analysis. Optimization employed soil fractionation data from 154 sites with diverse environmental conditions, directly equating mineral-associated organic matter and particulate organic matter fractions with corresponding model pools. Finally, model performance was evaluated using total topsoil (0–20 cm) C data from 8192 forest and grassland sites across Europe. Despite the relative simplicity of the model, it was able to accurately capture general trends in soil C stocks across extensive gradients of temperature, precipitation, annual C inputs and soil texture. The novel approach that MEMS v1.0 takes to simulate SOM dynamics has the potential to improve our forecasts of how soils respond to management and environmental perturbation. Ensuring these forecasts are accurate is key to effectively informing policy that can address the sustainability of ecosystem services and help mitigate climate change.

54 ENVIRONMENTAL SCIENCES↗

Exercise thermoregulation after 6 h of chair rest, 6 degrees head-down bed-rest, and water immersion deconditioning in men

The purpose was to investigate the mechanism for the excessive exercise hyperthermia following deconditioning (reduction of physical fitness). Rectal (Tre) and mean skin (Tsk) temperatures and thermoregulatory responses were measured in six men [mean (SD) age, 32 (6) years; mass, 78.26 (5.80) kg; surface area, 1.95 (0.11) m2; maximum oxygen uptake (VO2max), 48 (6) ml.min-1.kg-1; whilst supine in air at dry bulb temperature 23.2 (0.6) degree C, relative humidity 31.1 (11.1)% and air speed 5.6 (0.1) m.min-1] during 70 min of leg cycle exercise [51 (4)% VO2max] in ambulatory control (AC), or following 6 h of chair rest (CR), 6 degree head-down bed rest (BR), and 20 degree (WI20) and 80 degree (WI80) foot-down water immersion [water temperature, 35.0 (0.1) degree C]. Compared with the AC exercise delta Tre [mean (SD) 0.77 (0.13) degree C (*P < 0.05), after WI80 0.96 (0.13) degree C*, and after WI20 1.03 (0.09) degree C*. All Tsk responded similarly to exercise: they decreased (NS) by 0.5-0.7 degree C in minutes 4-8 and equilibrated at +0.1 to +0.5 degree C at 60-70. Skin heat conductance was not different among the five conditions (range = 147-159 kJ.m-2.h-1.degree C-1). Results from an intercorrelation matrix suggested that total body sweat rate was more closely related to Tre at 70 min (Tre70) than limb sweat rate or blood flow. Only 36% of the variability in Tre70 could be accounted for by total sweating, and less than 10% from total body dehydration. It would appear that multiple factors are involved which may include change in sensitivity of thermo- and osmoreceptors.

NASA Discipline Regulatory Physiology↗

Upconversion luminescence of Ho{sup 3+} sensitized by Yb{sup 3+} in transparent glass ceramic embedding BaYF{sub 5} nanocrystals

Transparent SiO{sub 2}-Al{sub 2}O{sub 3}-BaCO{sub 3}-YF{sub 3}-BaF{sub 2} glass ceramics co-doped with Yb{sup 3+}/Ho{sup 3+} ions were prepared by melt quenching and subsequent heating. X-ray diffraction and transmission electron microscopy observation revealed that BaYF{sub 5} nanocrystals incorporated with Yb{sup 3+} and Ho{sup 3+} were precipitated homogeneously among the oxide glass matrix. Three upconversion emission bands centered at 483 nm, 545 nm and 645 nm, corresponding to the {sup 5}F{sub 3} {yields} {sup 5}I{sub 8}, {sup 5}S{sub 2}, {sup 5}F{sub 4} {yields} {sup 5}I{sub 8} and {sup 5}F{sub 5} {yields} {sup 5}I{sub 8} transitions of Ho{sup 3+} respectively, were detected under 976 nm excitation, ascribing to the efficient energy transfer from Yb{sup 3+} to Ho{sup 3+}. The red emission is prevailing in the precursor glass, while the green one turns to be dominant in the glass ceramic.

36 MATERIALS SCIENCE↗

Surface Mechanoengineering of a Zr-based Bulk Metallic Glass via Ar-Nanobubble Doping to Probe Cell Sensitivity to Rigid Materials

In this paper, a new materials platform, utilizing the amorphous microstructure of bulk metallic glasses (BMGs) and the versatility of ion implantation, was developed for the fundamental investigation of cell responses to substrate-rigidity variations in the gigapascal modulus range, which was previously unattainable with polymeric materials. The surface rigidity of a Zr-Al- Ni-Cu-Y BMG was modulated with low-energy Ar-ion implantation owing to the impartment of Ar nanobubbles into the amorphous matrix. Surface softening was achieved due to the formation of nanobubble-doped transitional zones in the Zrbased BMG substrate. Bone-forming cell studies on this newly designed platform demonstrated that mechanical cues, accompanied with the potential effects of other surface properties (i.e. roughness, morphology, and chemistry), contributed to modulating cell behaviors. Cell adhesion and actin filaments were found to be less established on less stiff surfaces, especially on the surface with an elastic modulus of 51 GPa. Cell growth appeared to be affected by surface mechanical properties. A lower stiffness was generally related to a higher growth rate. Findings in this study broadened our fundamental understanding concerning the mechanosensing of bone cells on stiff substrates. It also suggests that surface mechano-engineering of metallic materials could be a potential strategy to promote osseointegration of such materials for bone-implant applications. Further investigations are proposed to fine tune the ion implantation variables in order to further distinguish the surface-mechanical effect on bone-forming cell activities from the contributions of other surface properties.

36 MATERIALS SCIENCE↗

Single Quadrupole Multiple Fragment Ion Monitoring Quantitative Mass Spectrometry

Single quadrupole mass spectrometry (MS) with enhanced in-source multiple fragment ion monitoring was designed to perform high sensitivity quantitative mass analyses. Enhanced in-source fragmentation amplifies fragmentation from traditional soft electrospray ionization producing fragment ions that have been found to be identical to those generated in tandem MS. We have combined enhanced in-source fragmentation data with criteria established by the European Union Commission Directive 2002/657/EC for electron ionization single quadrupole quantitative analysis to perform quantitative analyses. These experiments were performed on multiple types of complex samples that included a mixture of 50 standards, as well as cell and plasma extracts. The dynamic range for these quantitative analyses was comparable to triple quadrupole multiple reaction monitoring (MRM) analyses at up to 5 orders of magnitude with the cell and plasma extracts showing similar matrix effects across both platforms. Amino acid and fatty acid measurements performed from certified NIST 1950 plasma with isotopically labeled standards demonstrated accuracy in the range of 91–110% for the amino acids, 76–129% for the fatty acids, and good precision (coefficient of variation <10%). To enhance specificity, a newly developed correlated ion monitoring algorithm was designed to facilitate these analyses. This algorithm autonomously processes, aligns, filters, and compiles multiple ions within one chromatogram enabling both precursor and in-source fragment ions to be correlated within a single chromatogram, also enabling the detection of coeluting species based on precursor and fragment ion ratios. Single quadrupole instrumentation can provide MRM level quantitative performance by monitoring/correlating precursor and fragment ions facilitating high sensitivity analysis on existing single quadrupole instrumentation that are generally inexpensive, easy to operate, and technically less complex.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗