Search NASA⌕ Search

SEARCH · Search NASA

Results for “Software studies”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,189 records · Page 66

Simulation verification techniques study. Task report 4: Simulation module performance parameters and performance standards

Shuttle simulation software modules in the environment, crew station, vehicle configuration and vehicle dynamics categories are discussed. For each software module covered, a description of the module functions and operational modes, its interfaces with other modules, its stored data, inputs, performance parameters and critical performance parameters is given. Reference data sources which provide standards of performance are identified for each module. Performance verification methods are also discussed briefly.

Source record↗

A study of spacecraft technology and design concepts. Volume 2: Appendices

Electrical, mechanical, and software subsystem needs in the Post 1990 space operations environment are considered as well as the effect of radiation environment on spacecraft configuration. Criteria are given for selecting a specific design or technology concept from among the alternatives available.

Zylius, F. A.↗

A design study for a three-dimensional display computer terminal for meteorological information

The software developed on this project in FY-84 was put into final form and documented for McIDAS user access. The various users have been asked to utilize the techniques and to provide feedback to the developers. Researchers have received limited feedback to date, but nearly all has been helpful and generally favorable. The stereo display has been used by most of the operational users of McIDAS or its progenies. Specifically, the National Hurricane Center, the National Severe Storm Forecast Center, the National Meteorological Center, and the Cape Canaveral Forecast Facility have all made use of the 4-D display techniques to help evaluate meteorological situations on various occasions.

Suomi, V. E.↗

Data diversity: An approach to software fault tolerance

Data diversity is described, and the results of a pilot study are presented. The regions of the input space that cause failure for certain experimental programs are discussed, and data reexpression, the way in which alternate input data sets can be obtained, is examined. A description is given of the retry block which is the data-diverse equivalent of the recovery block, and a model of the retry block, together with some empirical results is presented. N-copy programming which is the data-diverse equivalent of N-version programming is considered, and a simple model and some empirical results are also given.

Ammann, Paul E.↗

Refactoring and Componentizing Legacy Codes: GMI Case Study

As Earth science applications grow increasingly complex over time, maintenance of such software becomes a significant challenge. In general, the software subsystems were designed, implemented and integrated (over an extended period of time) by different groups that did not follow the same software design standard. The objective was understandably to obtain scientific results quickly, but this goal was often achieved at the expense of good software practices. With that pattern of development, the cost of incremental changes to the applications grow ominously large. This increase in effort, tends to squeeze development resources and largely prevent any systematic attempt to reintroduce better software practices and thereby enhance the maintainability of the software. In this paper, we present the process we used to incrementally refactor and componentize the Global Modeling Initiative code to make it more understandable, maintainable, flexible and extensible. The resulting product not only preserves the scientific integrity of the original code but also extends the capabilities of the code for several applications.

Kouatchou, Jules↗

Sandia Complex Lifecycle Analysis Framework

Given a set of unit-process descriptions in Ecospold XML format, the software imports said descriptions and objectifies them into software objects dynamically linked into a process graph. The software then traverses this graph dynamically to compute a total inventory of inputs and effluents involved in the production of any represented anthropogenic substance or product. The software is capable of intelligently searching this graph to find upstream unit-process linkages based not only on the name of the unit-process, but also other attributes such as the geographic location of the unit-process, potential greenhouse gas (GHG) footprint of the unit-process, etc. In addition, the software can search based on metadata attributes such as the provenance of the unit-process data. These degrees of freedom enable the software to not only compute conventional LCI inventories but to perform process-substitution studies, optimized process chains, constraint-satisfied process chains, and temporally-optimized process chains taking into account how such chains might change over time. The software conducts Lifecycle Assessment (LCA) of GHGs based on the IPCC Global Warming Potential methodology.

Source record↗

Evaluation of various approaches for assessing dose indicators and patient organ doses resulting from radiotherapy cone-beam CT

Purpose: The aim of this study was to evaluate various approaches for assessing patient organ doses resulting from radiotherapy cone-beam CT (CBCT), by the use of thermoluminescent dosimeter (TLD) measurements in anthropomorphic phantoms, a Monte Carlo based dose calculation software, and different dose indicators as presently defined. Methods: Dose evaluations were performed on a CBCT Elekta XVI (Elekta, Crawley, UK) for different protocols and anatomical regions. The first part of the study focuses on using PCXMC software (PCXMC 2.0, STUK, Helsinki, Finland) for calculating organ doses, adapting the input parameters to simulate the exposure geometry, and beam dose distribution in an appropriate way. The calculated doses were compared to readouts of TLDs placed in an anthropomorphic Rando phantom. After this validation, the software was used for analyzing organ dose variability associated with patients’ differences in size and gender. At the same time, various dose indicators were evaluated: kerma area product (KAP), cumulative air-kerma at the isocenter (K{sub air}), cone-beam dose index, and central cumulative dose. The latter was evaluated in a single phantom and in a stack of three adjacent computed tomography dose index phantoms. Based on the different dose indicators, a set of coefficients was calculated to estimate organ doses for a range of patient morphologies, using their equivalent diameters. Results: Maximum organ doses were about 1 mGy for head and neck and 25 mGy for chest and pelvis protocols. The differences between PCXMC and TLDs doses were generally below 10% for organs within the field of view and approximately 15% for organs at the boundaries of the radiation beam. When considering patient size and gender variability, differences in organ doses up to 40% were observed especially in the pelvic region; for the organs in the thorax, the maximum differences ranged between 20% and 30%. Phantom dose indexes provided better correlation with organ doses than K{sub air} and KAP, with average ratios ranging between 0.9 and 1.1 and variations for different organs and protocols below 20%. The triple phantom setup allowed us to take into account scatter dose contributions, but nonetheless, the correlation with the evaluated organ doses was not improved with this method. Conclusions: The simulation of rotational geometry and of asymmetric beam distribution by means of PCXMC 2.0 enabled us to determine patient organ doses depending on weight, height and gender. Alternatively, the measurement of an in phantom dose indicator combined with proper correction coefficients can be a useful tool for a first dose estimation of in-field organs. The data and coefficients provided in this study can be applied to any patient undergoing a scan by an Elekta XVI equipment.

60 APPLIED LIFE SCIENCES↗

Low-latency NuMI Trigger for the CHIPS-5 Neutrino Detector

The CHIPS R&D project aims to develop affordable water Cherenkov detectors for large-scale underwater installations. In 2019, a 5kt prototype detector CHIPS-5 was deployed in northern Minnesota to study neutrinos generated by the nearby NuMI beam. This contribution presents a dedicated low-latency time distribution system for CHIPS-5 that delivers timing signals from the Fermilab accelerator to the detector with sub-nanosecond precision. Exploiting existing NOvA infrastructure, the time distribution system achieves this only with open-source software and conventional network elements. In a time-of-flight study, the presented system has reliably offered a time budget of $610 \pm 330\text{ ms}$ for on-site triggering. This permits advanced analysis in real-time as well as a novel hardware-assisted active triggering mode, which reduces DAQ computing load and network bandwidth outside triggered time windows.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Collective I/O Tuning Using Analytical and Machine-Learning Models

The ever larger demand of scientific applications for computation and data is currently driving a continuous increase in scale of parallel computers. The inherent complexity of scaling up a computing systems in terms of both hardware and software stack exposes an increasing number of factors impacting the performance and complicating the process of optimization. In particular, the optimization of parallel I/O has become increasingly challenging due to increasing storage hierarchy and well known performance variability of shared storage systems. This paper focuses on model-based autotuning of the two-phase collective I/O algorithm from a popular MPI distribution on the Blue Gene/Q architecture. We propose a novel hybrid model, constructed as a composition of analytical models for communication and storage operations and black-box models for the performance of the individual operations. We perform an in-depth study of the complexity involved in performance modeling including architecture, software stack and noise. In particular we address this challenges of modeling the performance of shared storage systems by building a benchmark that helps synthesizing factors such as topology, file caching, and noise. The experimental results show that the hybrid approach produces significantly better results than state-of-the-art machine learning approaches and shows a higher robustness to noise, at the cost of a higher modeling complexity

I/O performance modeling↗

Detailed studies of the nonperiodic time variability of several galactic X-ray sources

Computer software necessary for the analysis of the time variability of X-ray sources was developed and tested. Seventy-one Uhuru observations of the black hole candidate Cygnus X-1 were also examined. Data show that the X-ray emission can be best represented as arising from randomly occurring X-ray flares with a mean rate of occurrence of 18 flares/sec and a mean cooling time of approximately 1/2 sec. Furthermore data show that photons in the 2 to 16 keV bandwidth arise from within the same flares. Finally, it was found that the mean flare rate and cooling time have been constant since the source underwent a spectral transition in March 1971. Long term variations of several parameters associated with the X-ray emission from this object were studied.

Weisskopf, M. C.↗

Simulation studies related to the particle identification by the forward and backward RICH detectors at Electron Ion Collider

The Electron-Ion collider (EIC) will be the ultimate facility to study the dynamics played by colored quarks and gluons in the phenomenology of nucleons and nuclei, described by Quantum Chromodynamics. The physics programs will greatly rely on efficient particle identification (PID) in both the forward and the backward regions. The forward and the backward RICHes of the EIC have to be able to cover wide acceptance and momentum ranges; in the forward region a dual radiator RICH (dRICH) is foreseen and in the backward region a proximity-focusing RICH can be foreseen to be employed. The geometry and the performance studies of the dRICH have been performed as prescribed in the EIC Yellow Report using the ATHENA software framework. Furthermore, this part of our work reports the effort following the call for EIC detector proposal and the studies related to the forward and the backward RICH performance. In the forward region, the dRICH performance showed a pion- kaon separation from around 1 GeV/c to 50 GeV/c at a three sigma level; the proximity focusing RICH (pfRICH) foreseen for the backward region can reach three sigma separation up to 3 GeV/c for e/$π$ and up to 10 GeV/c for $π$/K mass hypotheses.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Retroreflection of Optical Radiation from Ellipsoidal-Porous Surfaces

The retroreflection of optical radiation from surfaces with roughness in the form of ellipsoidal pores and two-level roughness in the form of convex ellipsoids with elliptical-porous surfaces is studied using the ROKS-RG Monte-Carlo method software in the geometrical-optics approximation. The dependence of the retroreflection phase function on the parameters of bodies that simulates the rough surface is analyzed. It is shown that the angular dependence of the retroreflection from porous rough surfaces with arbitrarily oriented pores and the aspect ratio higher than unity is a pronounced peak with concave sides at all incidence angles.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

CFD Vision 2030 Study: A Path to Revolutionary Computational Aerosciences

This report documents the results of a study to address the long range, strategic planning required by NASA's Revolutionary Computational Aerosciences (RCA) program in the area of computational fluid dynamics (CFD), including future software and hardware requirements for High Performance Computing (HPC). Specifically, the "Vision 2030" CFD study is to provide a knowledge-based forecast of the future computational capabilities required for turbulent, transitional, and reacting flow simulations across a broad Mach number regime, and to lay the foundation for the development of a future framework and/or environment where physics-based, accurate predictions of complex turbulent flows, including flow separation, can be accomplished routinely and efficiently in cooperation with other physics-based simulations to enable multi-physics analysis and design. Specific technical requirements from the aerospace industrial and scientific communities were obtained to determine critical capability gaps, anticipated technical challenges, and impediments to achieving the target CFD capability in 2030. A preliminary development plan and roadmap were created to help focus investments in technology development to help achieve the CFD vision in 2030.

Jeffrey P Slotnick↗

Regenerator design optimization: Results from REGEN 3.3

The results from an extensive parametric study using the most recent version of the regenerator design software tool, REGEN3.3, are presented. By compiling the results from more than 10,000 applications of REGEN3.3 for three different temperatures (35 K, 60 K and 80 K), a wide range of frequencies (30–300 Hz), and a variety of regenerator length, inverse mass flux, and cold end phase angles, a group of performance maps have been generated that will enable regenerator optimization without having to learn REGEN3.3. Optimum results, defined by maximum COP values, are also provided in the form of a convenient correlation whereby the COP can be calculated directly from chosen values of cold end temperature, frequency, inverse mass flux, length, and cold end phase angle. Here one of the more interesting results revealed by this study is that the optimum value of COP is very broad. That is, changes by as much as 15% to 20% in the length, inverse mass flux, or cold end phase away from their optimized values degrade the COP by only 2%.

42 ENGINEERING↗

Required Time of Arrival as a Control Mechanism to Mitigate Uncertainty in Arrival Traffic Demand Management

The objective of this study is to explore the use of Required Time of Arrival (RTA) capability on the flight deck as a control mechanism on arrival traffic management to improve traffic delivery accuracy by mitigating the effect of traffic demand uncertainty. The uncertainties are caused by various factors, such as departure error due to the difference between scheduled departure and the actual take-off time. A simulation study was conducted using the Multi Aircraft Control System (MACS) software, a comprehensive research platform developed in the Airspace Operations Laboratory (AOL) at NASA Ames Research Center. The Crossing Time (CT) performance (i.e. the difference between target crossing time and actual crossing time) of the RTA for uncertainty mitigation during cruise phase was evaluated under the influence of varying two main factors: wind severity (heavy wind vs. mild wind), and wind error (1 hour, 2 hours, and 5 hours wind forecast errors). To examine the CT performance improvement made by the RTA, the comparison to the CT of the aircraft that were not assigned with RTA (Non-RTA) under the influence of the selected factors was also made. The Newark Liberty International Airport (EWR) was chosen for this study. A total 66 inbound traffic to the EWR (34 of them were airborne when the simulation was initiated, 32 were pre-departures at that time) was simulated, where the pre-scripted departure error was assigned to each pre-departure (61 conform to their Expected Departure Clearance Time, which is +-300 seconds of their scheduled departure time). The results of the study show that the delivery accuracy improvement can be achieved by assigning RTA, regardless of the influence of the selected two factors (the wind severity and the wind information inaccuracy). Across all wind variances, 66.9 (265 out of 396) of the CT performance of the RTA assigned aircraft was within +- 60 seconds (i.e. target tolerance range) and 88.9 (352 out of 396) aircraft met +-300 seconds marginal tolerance range, while only 33.6 (133 out of 396) of the Non-RTA assigned aircrafts CT performance achieved the target tolerance range and 75.5 (299 out of 396) stayed within the marginal. Examination of the impact of different error sources i.e. departure error, wind severity, and wind error suggest that although large departure errors can significantly impact the CT performance, the impacts of wind severity and errors were modest relative the targeted +- 60 second conformance range.

required time of arrival (RTA)↗

Fundus image fusion in EYEPLAN software: An evaluation of a novel technique for ocular melanoma radiation treatment planning

Purpose: The purpose of this study is to evaluate a novel approach for treatment planning using digital fundus image fusion in EYEPLAN for proton beam radiation therapy (PBRT) planning for ocular melanoma. The authors used a prototype version of EYEPLAN software, which allows for digital registration of high-resolution fundus photographs. The authors examined the improvement in tumor localization by replanning with the addition of fundus photo superimposition in patients with macular area tumors. Methods: The new version of EYEPLAN (v3.05) software allows for the registration of fundus photographs as a background image. This is then used in conjunction with clinical examination, tantalum marker clips, surgeon's mapping, and ultrasound to draw the tumor contour accurately. In order to determine if the fundus image superimposition helps in tumor delineation and treatment planning, the authors identified 79 patients with choroidal melanoma in the macular location that were treated with PBRT. All patients were treated to a dose of 56 GyE in four fractions. The authors reviewed and replanned all 79 macular melanoma cases with superimposition of pretreatment and post-treatment fundus imaging in the new EYEPLAN software. For patients with no local failure, the authors analyzed whether fundus photograph fusion accurately depicted and confirmed tumor volumes as outlined in the original treatment plan. For patients with local failure, the authors determined whether the addition of the fundus photograph might have benefited in terms of more accurate tumor volume delineation. Results: The mean follow-up of patients was 33.6{+-}23 months. Tumor growth was seen in six eyes of the 79 macular lesions. All six patients were marginal failures or tumor miss in the region of dose fall-off, including one patient with both in-field recurrence as well as marginal. Among the six recurrences, three were managed by enucleation and one underwent retreatment with proton therapy. Three patients developed distant metastasis and all three patients have since died. The replanning of six patients with their original fundus photograph superimposed showed that in four cases, the treatment field adequately covered the tumor volume. In the other two patients, the overlaid fundus photographs indicated the area of marginal miss. The replanning with the fundus photograph showed improved tumor coverage in these two macular lesions. For the remaining patients without local failure, replanning with fundus photograph superimposition confirmed the tumor volume as drawn in the original treatment plan. Conclusions: Local control was excellent in patients receiving 56 GyE of PBRT for uveal melanomas in the macular region, which traditionally can be more difficult to control. Posterior lesions are better defined with the additional use of fundus image since they can be difficult to mark surgically. In one-third of treatment failing patients, the superposition of the fundus photograph would have clearly allowed improved localization of tumor. The current practice standard is to use the superimposition of the fundus photograph in addition to the surgeon's clinical and clip mapping of the tumor and ultrasound measurement to draw the tumor volume.

60 APPLIED LIFE SCIENCES↗

Improved image quality of cone beam CT scans for radiotherapy image guidance using fiber-interspaced antiscatter grid

Purpose: Medical linear accelerator mounted cone beam CT (CBCT) scanner provides useful soft tissue contrast for purposes of image guidance in radiotherapy. The presence of extensive scattered radiation has a negative effect on soft tissue visibility and uniformity of CBCT scans. Antiscatter grids (ASG) are used in the field of diagnostic radiography to mitigate the scatter. They usually do increase the contrast of the scan, but simultaneously increase the noise. Therefore, and considering other scatter mitigation mechanisms present in a CBCT scanner, the applicability of ASGs with aluminum interspacing for a wide range of imaging conditions has been inconclusive in previous studies. In recent years, grids using fiber interspacers have appeared, providing grids with higher scatter rejection while maintaining reasonable transmission of primary radiation. The purpose of this study was to evaluate the impact of one such grid on CBCT image quality. Methods: The grid used (Philips Medical Systems) had ratio of 21:1, frequency 36 lp/cm, and nominal selectivity of 11.9. It was mounted on the kV flat panel detector of an Elekta Synergy linear accelerator and tested in a phantom and a clinical study. Due to the flex of the linac and presence of gridline artifacts an angle dependent gain correction algorithm was devised to mitigate resulting artifacts. Scan reconstruction was performed using XVI4.5 augmented with inhouse developed image lag correction and Hounsfield unit calibration. To determine the necessary parameters for Hounsfield unit calibration and software scatter correction parameters, the Catphan 600 (The Phantom Laboratory) phantom was used. Image quality parameters were evaluated using CIRS CBCT Image Quality and Electron Density Phantom (CIRS) in two different geometries: one modeling head and neck and other pelvic region. Phantoms were acquired with and without the grid and reconstructed with and without software correction which was adapted for the different acquisition scenarios. Parameters used in the phantom study weret{sub cup} for nonuniformity and contrast-to-noise ratio (CNR) for soft tissue visibility. Clinical scans were evaluated in an observer study in which four experienced radiotherapy technologists rated soft tissue visibility and uniformity of scans with and without the grid. Results: The proposed angle dependent gain correction algorithm suppressed the visible ring artifacts. Grid had a beneficial impact on nonuniformity, contrast to noise ratio, and Hounsfield unit accuracy for both scanning geometries. The nonuniformity reduced by 90% for head sized object and 91% for pelvic-sized object. CNR improved compared to no corrections on average by a factor 2.8 for the head sized object, and 2.2 for the pelvic sized phantom. Grid outperformed software correction alone, but adding additional software correction to the grid was overall the best strategy. In the observer study, a significant improvement was found in both soft tissue visibility and nonuniformity of scans when grid is used. Conclusions: The evaluated fiber-interspaced grid improved the image quality of the CBCT system for broad range of imaging conditions. Clinical scans show significant improvement in soft tissue visibility and uniformity without the need to increase the imaging dose.

60 APPLIED LIFE SCIENCES↗

Experience Report for WOPR

One of the purposes of the SQA effort at LLNL is to attempt to determine the 'goodness' of the research codes used for various scientific applications. Typically these are two and three dimensional multi-physics simulation and modeling codes. These legacy research codes are used for applciations such as atmospheric dispersion modeling and analysis and prediction of the performance of engineered systems. These codes are continually subjected to automated regression test suites consisting of verified and validated expected results. Code is managed in repositories. Experience level of developers is high in the knowledge domain, platforms, and languages used. Code size of the multi-physics code used in this study was 578,242 lines excluding comment and blank lines or 5538.7 function points. Languages were 70% C++, 20% C, and 10% Fortran. The code has 130 users and a development team of 14 and an embedded SQE. The code has achieved 100% prime feature test coverage, 73.6% functional test coverage, and 71.5% statement test coverage. The average cyclomatic complexity of the code was 6.25. The codes have evolved over 10 years. Research codes are challenging because there is a desire to balance agility with discipline as well as compliance with DOE standards. Agility is important to allow experimentation with new algorithms and addition of the latest physics features. Discipline is important to increase the quality of the codes. Automation of processes and defect prevention/detection are deployed throughout the software development process. Since resarch codes are a small segment of the software industry, not much information exists in terms of reliability studies on these types of codes. This paper describes attempts to determine the goodness of these research codes. Goodness defined as both correctness of the codes and their fault densities. Correctness is determined by user interviews, peer review; feature based automated testing, and coverage measurement. This paper focuses on the fault density aspect of goodness and reliability of the codes in particular. The approach taken was to use multiple fault density prediction methods and compare results to actual experimentation and other industry studies on fault density. As a result of the predictions and experiments our confidence in the prediction methods was increased and our confidence in the goodness of the code from a fault density perspective was given more context. A large unintended benefit of these experiments was to find defects hidden for years in the codes when using the Monte Carlo reliability testing results to develop heuristic based bug driven tests.

99 GENERAL AND MISCELLANEOUS↗