Search NASA⌕ Search

SEARCH · Search NASA

Results for “THERMOCOUPLES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,189 records · Page 66

Experimental clean combustor program: Noise study

Under a Noise Addendum to the NASA Experimental Clean Combustor Program (ECCP) internal pressure fluctuations were measured during tests of JT9D combustor designs conducted in a burner test rig. Measurements were correlated with burner operating parameters using an expression relating farfield noise to these parameters. For a given combustor, variation of internal noise with operating parameters was reasonably well predicted by this expression but the levels were higher than farfield predictions and differed significantly among several combustors. For two burners, discharge stream temperature fluctuations were obtained with fast-response thermocouples to allow calculation of indirect combustion noise which would be generated by passage of the temperature inhomogeneities through the high pressure turbine stages of a JT9D turbofan engine. Using a previously developed analysis, the computed indirect combustion noise was significantly lower than total low frequency core noise observed on this and several other engines.

Sofrin, T. G.↗

Results from a convective heat transfer rate distribution test on a 0.0175 scale model (22-0) of the Rockwell International vehicle 4 space shuttle configuration in the AEDC-VKF tunnel B (OH49B), volume 1

The tests were conducted in a hypersonic wind tunnel at Mach number 8 to investigate reentry mode convective heat--transfer rates to the vehicle 4 shuttle orbiter. The thin skin thermocouple technique was used to obtain the heat transfer rate measurements. A complete set of tabulated data is presented.

Herrera, B. J.↗

Heat-transfer distributions on a 0.013-scale shuttle solid rocket booster at Mach 3.70 and angles of attack from 0 deg to 180 deg

An experimental investigation was conducted in the Langley Unitary Plan wind tunnel to estimate the peak aerodynamic heating on the space shuttle solid rocket booster during the descent phase of its flight. Heat transfer measurements were obtained using 0.013 scale models instrumented with thermocouples at a Mach number of 3.70, Reynolds number per meter of 11.48 million, and angles of attack from 0 to 180 deg. At angles of attack of 0 and 180 deg, heat transfer measurements on the cylindrical section of the model between the conical nose and ring interaction region were in good agreement with flat plate strip theory for laminar and turbulent flow. At angles of attack up to 30 deg, measurements on this section of the model were in good agreement with laminar swept-cylinder theory, whereas at angles of attack from 120 to 180 deg, the measurements were in good agreement with turbulent swept-cylinder theory. The good agreement with turbulent theory indicated that large flow disturbances created by the nozzle and afterbody flare at these large angles of attack influenced the downstream heating primarily by promoting boundary layer transition. Measurements obtained at 90 deg angle of attack were indicative of laminar flow.

Lamb, M.↗

Heat-transfer test results for a .0275-scale space shuttle external tank with a 10 deg/40 deg double cone-ogive nose in the NASA/AMES 3.5-foot hypersonic wind tunnel (FH14), volume 2

A .0275 scale forebody model of the new baseline configuration of the space shuttle external tank vent cap configuration was tested to determine the flow field due to the double cone configuration. The tests were conducted in a 3.5 foot hypersonic wind tunnel at alpha = -5 deg, -4.59 deg, 0 deg, 5 deg, and 10 deg; beta = 0 deg, -3 deg, -5.51 deg, -6 deg, -9 deg, and +6 deg; nominal freestream Reynolds numbers per foot of 1.5 x 1 million, 3.0 x 1 million, and 5.0 x 1 million; and a nominal Mach number of 5. Separation and reattached flow from thermocouple data, shadowgraphs, and oil flows indicate that separation begins about 80% from the tip of the 10 deg cone, then reattaches on the vent cap and produces fully turbulent flow over most of the model forebody. The hardware disturbs the flow over a much larger area than present TPS application has assumed. A correction to the flow disturbance was experimentally suggested from the results of an additional test run.

Carroll, H. R.↗

Apparatus for determining thermophysical properties of test specimens

Apparatus is described for directly measuring the quantity square root of pck of a test specimen such as a wind tunnel model where p is density, c is the specific heat and k is the thermal conductivity of the specimen. The test specimen and a reference specimen are simultaneously subjected to the heat from a heat source. A thermocouple is attached to the reference specimen for producing a first electrical analog signal proportional to the heat rate Q that the test specimen is subjected to and an infrared radiometer that is aimed at the test specimen produces a second electrical analog signal proportional to the surface temperature T of the test specimen. An analog-to-digital converter converts the first and second electrical analog signals to digital signals. These digital signals are applied to a computer for determining the quantity.

Creel, T. R., Jr.↗

A low cost, portable instrument for measuring emittance

A low cost, portable instrument was developed with which emittance can be measured by comparison to a standard. A reflector collects infrared radiation from a heated sample onto a low mass, black detector and the temperature rise of the black detector is measured with a thermocouple and meter. Graphical examples are presented for determination of emittance from measurements made on a sample at any known temperature.

Mcdonald, G.↗

Experimental investigation of flow turbulence effects on premixed methane-air flames

An experimental assessment of a novel technique for measuring turbulent flame speeds was conducted. Unconfined, V-shaped, methane-air flames stabilized in grid turbulence were investigated. Local flame speeds were measured employing hot film and laser anemometry and fine wire thermocouples. The measurement instrumentation was extended to provide mean and fluctuating temperature information about turbulent flames. The flames in grid turbulence exhibited an increase in flame speed with increased length scale and velocity fluctuations. At high combustor velocities, stabilizer wake turbulence dominated the flame properties.

Smith, K. O.↗

Effect of ambient temperature on the thermal profile of the human forearm, hand, and fingers

Forearm, hand, and finger skin temperatures were measured on the right and left sides of seven resting men. The purpose was to determine the bilateral symmetry of these segmental temperature profiles at ambient temperatures from 10 to 45 C. Thermistors placed on the right and left forearms, hands, and index fingers were used to monitor the subjects until equilibration was reached at each ambient temperature. Additionally, thermal profiles of both hands were measured with copper-constantan thermocouples. During one experimental condition (23 C ambient), rectal, ear canal, and 24 skin temperatures were measured on each subject. Average body and average skin temperatures are given for each subject at the 23 C ambient condition. Detailed thermal profiles are also presented for the dorsal, ventral, and circumferential left forearm, hand, and finger skin temperatures at 23 C ambient. No significant differences were found between the mean skin temperatures of the right and left contralateral segments at any of the selected ambient temperatures.

Montgomery, L. D.↗

Controlled freezing of biological samples

Apparatus consists of thermocouple connected to semiconductor reference junction. Junction is connected to amplifier that boosts signal by 1,000. High-level signal is displayed on recorder and fed into second amplifier where it is compared with signal from potentiometer of programmed dc reference in bag-temperature programer. Difference in signals indicates output voltage. Remaining circuitry provides zero-phase, time-proportion control of heaters such that heater power is directly proportional to error signal.

Cygnarowicz, T. A.↗

Body/bone-marrow differential-temperature sensor

Differential-temperature sensor developed to compare bone-marrow and body temperature in leukemia patients uses single stable amplifier to monitor temperature difference recorded by thermocouples. Errors are reduced by referencing temperatures to each other, not to separate calibration points.

Anselmo, V. J.↗

Calibration target for temperature radiometer

Technique measures temperature/voltage drop characteristics of very thin filament. With constant current running through filament, voltage drop is recorded at various temperatures, as measured by calibrated thermocouple.

Edwards, S. F.↗

Predicting surface heat flux

Report presents technique involving single embedded thermocouple used to predict flux and temperature for high-or-low conductivity materials that have temperature-and-pressure dependent properties. Technique solves for heat rate and temperature at given surface at each time step, rather than for entire history. Newton-Raphson technique is used for temperature solutions; then quadratic fit is employed. Report contains representative graphs and tables.

Curry, D. M.↗

Internal grid for release of brazing retorts

Wire grid permits retorts to be opened more quickly after brazing. Grid also aids purging and evacuation, better control of vacuum in part area, and reduces thermocouple damage.

Beuyukian, C. S.↗

Wind-tunnel investigation of aerodynamic performance, steady amd vibratory loads, surface temperatures, and acoustic characteristics of a large-scale twin-engine upper-surface blown jet-flap configuration

Static and wind-on tests were conducted to determine the aerodynamic characteristics of and the effects of jet impingement on the wing of a large scale upper surface blown configuration powered with an actual turbine engine. The wing and flaps were instrumented with experimental dual-sensing transducer units consisting of a fluctuating pressure gage, a vibratory accelerometer, and a surface mounted alumel thermocouple. Noise directivity and spectral content measurements were obtained for various flap configurations and various engine thrust settings to provide baseline noise data for other upper surface blown configurations.

Source record↗

Conceptual design for spacelab pool boiling experiment

A pool boiling heat transfer experiment to be incorporated with a larger two-phase flow experiment on Spacelab was designed to confirm (or alter) the results of earth-normal gravity experiments which indicate that the hydrodynamic peak and minimum pool boiling heat fluxes vanish at very low gravity. Twelve small sealed test cells containing water, methanol or Freon 113 and cylindrical heaters of various sizes are to be built. Each cell will be subjected to one or more 45 sec tests in which the surface heat flux on the heaters is increased linearly until the surface temperature reaches a limiting value of 500 C. The entire boiling process will be photographed in slow-motion. Boiling curves will be constructed from thermocouple and electric input data, for comparison with the motion picture records. The conduct of the experiment will require no more than a few hours of operator time.

Lienhard, J. H.↗

A low cost, portable instrument for measuring emittance

A low cost, portable instrument has been developed with which emittance can be measured by comparison to a standard. A reflector collects infra-red radiation from a heated sample onto a low mass, black detector and the temperature rise of the black detector is measured with a thermocouple and meter. Graphical examples are presented for determination of emittance from measurements made on a sample at any known temperature.

Mcdonald, G.↗

Lamination residual strains and stresses in hybrid laminates

An investigation is conducted of the effects of hybridization on the magnitude of lamination residual stresses. Eight-ply graphite/Kevlar 49/epoxy and graphite/S-glass/epoxy laminates were studied. The same matrix resin was selected for all basic materials to ensure compatibility and uniform curing of the various plies. The specimens, with inserted strain gages and thermocouples, were subjected to curing and postcuring cycles in an autoclave. Subsequently, the specimens were subjected to a thermal cycle from room temperature to 444 K and down to room temperature. It was found that hydridizing reduces apparently residual strains and stresses in the graphite plies. However, these strains were not affected much by the type and degree of hybridization.

Daniel, I. M.↗

Instrumentation techniques for studying heterogeneous combustion

Velocity measurements in flames and the simultaneous measurement of droplet size and velocity with the aid of laser anemometry are considered along with methods of particle size measurement and techniques based on laser Raman spectroscopy. Attention is given to high-speed photography and holography, computer compensated thermocouples, and the determination of turbulence characteristics. The employment of suction probes is also discussed, taking into account sampling methods, the effects of temperature change in sampling probes on particle formation, and the chemical analysis of samples.

Chigier, N. A.↗