Search NASA⌕ Search

SEARCH · Search NASA

Results for “Temperature Gradient”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,189 records · Page 66

Is There a Scalar Atmospheric Surface Layer Within a Convective Boundary Layer? Implications for Flux Measurements

Top‐down entrainment shapes the vertical gradients of sensible heat, latent heat, and CO 2 fluxes, influencing the interpretation of eddy covariance (EC) measurements in the unstable atmospheric surface layer (ASL). Using large eddy simulations for convective boundary layer flows, we demonstrate that decreased temperature gradients across the entrainment zone increase entrainment fluxes by enhancing the entrainment velocity, amplifying the asymmetry between top‐down and bottom‐up flux contributions. These changes alter scalar flux profiles, causing flux divergence or convergence and leading to the breakdown of the constant flux layer assumption (CFLA) in the ASL. As a result, EC‐measured fluxes either underestimate or overestimate “true” surface fluxes during divergence or convergence phases, contributing to energy balance non‐closure. The varying degrees of the CFLA breakdown are a fundamental cause for the non‐closure issue. These findings highlight the underappreciated role of entrainment in interpreting EC fluxes, addressing non‐closure, and understanding site‐to‐site variability in flux measurements.

eddy covariance fluxes of scalars↗

All-Optical Cryogenic Thermometry Based on Nitrogen-Vacancy Centers in Nanodiamonds

The nitrogen-vacancy (N-V) center in diamond has been viewed as a high-sensitivity nanometer-scale metrology platform. Thermometry has been a current focus, with attention largely confined to room-temperature applications. Temperature sensing at low temperatures, yet, remains challenging as the sensitivity decreases for many commonly used techniques, which rely on a temperature-dependent frequency shift of the N-V center's spin resonance and its control with microwaves. Here we use an alternative method that does not require microwaves, ratiometric all-optical thermometry, and demonstrate that it may be utilized to liquid-nitrogen temperatures without deterioration of the sensitivity. The use of an array of nanodiamonds embedded within a portable polydimethylsiloxane sheet provides a versatile temperature-sensing platform that can probe a wide variety of systems without the configurational restrictions needed for applying microwaves. With this device, we observe a temperature gradient over tens of microns in a ferromagnetic-insulator substrate (yttrium iron garnet) under local heating by a resistive heater. This thermometry technique provides a cryogenically compatible, microwave-free, minimally invasive approach capable of probing local temperatures with few restrictions on the substrate materials.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Impact of Irradiation-Induced Filter Heating on Calibration of NIR-Longpass-Filtered Reference Solar Cells

Reference solar cells play a crucial role in determining the performance of photovoltaic (PV) devices. In the performance calibration chain of mainstream single-junction PV technologies, common reference cell types include Si, KG-filtered Si, and GaAs cells. For emerging multijunction (MJ) PV technologies, such as CdTe/Si and perovskite/Si, Si reference cells with colored glass near-infrared-longpass (LP) filters like Schott RG-715 and 850 glass have been proposed. They offer a better spectral response that matches the bottom junctions of the emerging MJs, which could lead to lower uncertainties in performance measurements. However, this article reveals a prominent decrease in short-circuit current (ISC) during National Renewable Energy Laboratory's primary calibration over the course of minutes when using this type of LP-filtered reference cell, which could result in unacceptable measurement errors. Unlike quartz or KG filter glasses, LP colored glass filters demonstrate temperature-sensitive cut-on wavelength. When incident irradiance reaches these LP-filtered reference cells, the increased temperature due to light absorption causes a shift of the cut-on to longer wavelength. As a result, the device I SC exhibits a continuous decrease (approximately a 2.5% drop with RG850 LP filter in a 5-min duration) even when the device temperature is controlled at 25 degrees C. To address the temperature gradient issue between colored glass LP filter and the reference cell, we propose the direct integration of thin-film LP semiconductor layer on reference cells. This type of LP-filter-integrated cell has shown minimal temperature-related I SC variation and can serve as a more reliable reference cell source for accurate performance measurements.

14 SOLAR ENERGY↗

Observations of Aerosol, Cloud, Turbulence, and Radiation Properties at the Top of the Marine Boundary Layer over the Eastern North Atlantic Ocean: The ACORES Campaign

We report on the Azores Stratocumulus Measurements of Radiation, Turbulence and Aerosols (ACORES) campaign, which took place around Graciosa and Pico Islands/Azores in July 2017. The main objective was to investigate the vertical distribution of aerosol particles, stratocumulus microphysical and radiative properties, and turbulence parameters in the eastern North Atlantic. The vertical exchange of mass, momentum, and energy between the free troposphere (FT) and the cloudy marine boundary layer (MBL) was explored over a range of scales from submeters to kilometers. To cover these spatial scales with appropriate measurements, helicopter-borne observations with unprecedented high resolution were realized using the Airborne Cloud Turbulence Observation System (ACTOS) and Spectral Modular Airborne Radiation Measurement System–Helicopter-Borne Observations (SMART-HELIOS) instrumental payloads. Here, the helicopter-borne observations were combined with ground-based aerosol measurements collected at two continuously running field stations on Pico Mountain (2,225 m above sea level, in the FT), and at the Atmospheric Radiation Measurement (ARM) station on Graciosa (at sea level). First findings from the ACORES observations we are discussing in the paper are as follows: (i) we have observed a high variability of the turbulent cloud-top structure on horizontal scales below 100 m with local temperature gradients of up to 4 K over less than 1 m vertical distance, (ii) we have collected strictly collocated radiation measurements supporting the relevance of small-scale processes by revealing significant inhomogeneities in cloud-top brightness temperature to scales well below 100 m, and (iii) we have concluded that aerosol properties are completely different in the MBL and FT with often-complex stratification and frequently observed burst-like new particle formation.

54 ENVIRONMENTAL SCIENCES↗

Temperature and circulation in the stratospheres of the outer planets

A zonally symmetric, linear radiative-dynamical model is compared with observations of the upper tropospheres and stratospheres of the outer planets. Seasonal variation is included in the model. Friction is parameterized by linear drag (Rayleigh friction). Gas opacities are accounted for but aerosols are omitted. Horizontal temperature gradients are small on all the planets. Seasonal effects are strongest on Saturn and Neptune but are weak even in these cases, because the latitudinal gradient of radiative heating is weak. Seasonal effects on Uranus are extremely weak because the radiative time constant is longer that the orbital period. One free parameter in the model is the frictional time constant. Comparison with observed temperature perturbations over zonal currents in the troposphere shows that the frictional time constant is on the same order as the radiative time constant for all these objects. Vertical motions predicted by the model are extremely weak. They are much smaller than one scale height per orbital period, except in the immediate neighborhood of tropospheric and zonal currents.

Conrath, Barney J.↗

Temperature and circulation in the stratosphere of the outer planets

A zonally symmetric, linear radiative-dynamical model is compared with observations of the upper tropospheres and stratospheres of the outer planets. Seasonal variation is included in the model. Friction is parameterized by linear drag (Rayleigh friction). Gas opacities are accounted for but aerosols are omitted. Horizontal temperature gradients are small on all the planets. Seasonal effects are strongest on Saturn and Neptune but are weak even in these cases, because the latitudinal gradient of radiative heating is weak. Seasonal effects on Uranus are extremely weak because the radiative time constant is longer than the orbital period. One free parameter in the model is the frictional time constant. Comparison with observed temperature perturbations over zonal currents in the troposphere shows that the frictional time constant is on the same order as the radiative time constant for all these objects. Vertical motions predicted by the model are extremely weak. They are much smaller than one scale height per orbital period, except in the immediate neighborhood of tropospheric and zonal currents.

Conrath, Barney J.↗

MRP and NEAMS Meeting - Current Modeling to Support Experiments

Heat-pipe cooled micro-reactor is currently being actively investigated in the NS&T department at INL. Given the high operation temperature and large temperature gradients in the system, the induced thermal stresses need to be well analyzed and kept within the safety margin. Two commercial FEM software (ABAQUS and STAR-CCM+) have been proposed to simulate and compare for both the temperature and stress distributions for the single heat pipe experiments, with the middle single heat pipe and 6 heaters surrounded. This presentation file is aimed to provide the latest updates for the researchers who is under NEAMS program and involved with the DOE micro-reactor program

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Oxygen Solubility in Aqueous Amine Solvents with Common Additives Used for CO 2 Chemical Absorption

Major sources of anthropogenic CO 2 are power generation and transportation industries where researcher continue to explore CO 2 emission mitigation strategies as applied to these CO 2 sources through carbon capture, utilization, and sequestration (CCUS). The most mature CO 2 capture technology is post-combustion carbon capture (PCCC) using aqueous amine solutions/solvents, however solvent degradation and regeneration costs are slowing the widespread adoption of PCCC. Solvent degradation of the aqueous amine solutions is mainly caused from the temperature gradient between the absorber and stripper columns and common flue gas components such as SOx, NOx, and oxygen (O 2 ). The two main classifications of solvent degradation are thermal degradation, occurring when the amine reacts with itself at elevated temperatures and anaerobic conditions and oxidative degradation. Oxidative degradation reactions can occur from oxygen mass transfer and free radical oxidation. Metals, such as iron from the corrosion of steel structures used in industrial applications such as PCCC, can help to catalyze these reactions. Various oxidative degradation studies have shown how O 2 concentrations in flue gas and, to a lesser extent, temperature influence the extent of oxidative degradation. Accurately measuring the O 2 solubility, commonly referred to as dissolved oxygen (DO), in a quick, continuous, and efficient manner in aqueous amine solvents should contribute to determine the effectiveness of mitigation strategies for oxidative degradation. Knowing that commercial PCCC amine solvents contain components beyond water, amine, carbonate species and CO 2 , this investigation was conducted to determine the oxygen solubility changes of common aqueous amines solutions with commonly used and published solvent additives. The impact of carbon loadings with and without the additives was also examined. A commercial dissolved oxygen probe was used to measure the DO concentrations and compared them against standard Winkler Method titration values. The results show that antifoam shows minimal change in [DO]. MBT yielded lower DO values, and NaVO 3 showed a higher DO concentration due to interferences. These results indicate that most common amine solvent additives should be expected to minimally impact oxygen solubility and amine oxidative degradation.

60 APPLIED LIFE SCIENCES↗

Measurements of H-beta, He D3, and Ca/+/ 8542-A line emission in quiescent prominences

Measurements of H-beta, He D3, and Ca(+) 8542-A line emission in 18 quiescent prominences are presented which were performed with a 25-cm coronagraph/coude spectrograph system and an optical multichannel analyzer utilizing a Si-vidicon detector assembly mounted at the single-pass spectrograph port. The data obtained show that the line profiles deviate in the wings from those calculated on the basis of an isothermal atmosphere and a Gaussian absorption coefficient. Both a non-Gaussian microturbulence component and a temperature gradient from prominence-core to coronal values can successfully account for this phenomenon. The line widths from a given line of sight of prominence material are reduced on the basis of a common core emitting region with a temperature of 7500 to 11,600 K and a microturbulent velocity of 4.5 to 7.1 km/s for the isothermal model (these values are 5% to 10% less for the two-temperature model). It is noted that long-period low-amplitude oscillations in the D3 line width and intensity were observed when a specific line of sight in a quiescent prominence was followed. These oscillations are found to remain coherent for as many as 3 or 4 cycles and to be associated with prominence structural activation.

Landman, D. A.↗

The influence of gas velocity on surface heat pumping for the orifice pulse tube refrigerator

The basic pulse tube refrigerator produces cooling by a mechanism known as surface heat pumping. Cyclical compression and expansion of a gas within an enclosed tube produces large temperature gradients. The purpose of the tube is to act as 'nodal regenerator'. Heat is stored at node positions along the tube wall and is transported between nodes by moving gas parcels. This process gives rise to refrigeration, with hot temperatures at the closed end and cold temperatures at the open end. Unfortunately, much of the available refrigeration is not realized because the closed end of the basic pulse tube restricts gas movement - gas at the extreme temperatures does not come in contact with the heat exchangers. The orifice pulse tube overcomes this limitation by using a valve and surge volume assembly at the warm, closed end. This allows for a residual gas velocity to remain present during the heat transfer process, thereby permitting more gas to exchange heat at the heat exchangers. This paper describes the pulse tube as a nodal regenerator and the effect residual gas velocity has on the heat transfer mechanism of the orifice pulse tube.

Lee, J. M.↗

Cryogenic Vacuum Chamber Testing of A Conductively-Cooled, High Temperature Superconducting Rotor for a 1.4 MW Electric Machine for Aeronautics Applications

This paper presents the second ever demonstration of a superconducting rotor cooled only via conductive connection to a cryocooler, i.e., without pumped or solid cryogens. The fullscale rotor was operated statically in its intended environment – about 1e-3 torr vacuum with only conductive cooling through mechanical connections to a cryocooler contained on the rotor. Stable operation of the rotor in a representative magnetic environment was demonstrated up to its rated direct current (57.2 A) and the designed temperature limit for the superconductor (62 K). Additional electrical measurements increased confidence that the superconducting coils functioned as intended. A collection of steady state temperature distributions was measured at operating and non-operating conditions. In all but one case, the observed temperature gradient between the cold tip and superconducting coils satisfies the design but with little margin. Opportunities to reduce the gradient are identified.

Electrified aircraft propulsion↗

Cryogenic Vacuum Chamber Testing of A Conductively-Cooled, High Temperature Superconducting Rotor for a 1.4 MW Electric Machine for Aeronautics Applications

This paper presents the first ever demonstration of a superconducting rotor cooled conductively without a cryogenic fluid or solid. The full-scale rotor was operated statically in its intended environment – about 1e-3 torr vacuum with only conductive cooling through mechanical connections to a cryocooler contained on the rotor. Stable operation of the rotor in a representative magnetic environment was demonstrated up to its rated direct current (57.2 A) and the designed temperature limit for the superconductor (62 K). Additional electrical measurements increased confidence that the superconducting coils functioned as intended. A collection of steady state temperature distributions was measured at operating and non-operating conditions. In all but one case, the observed temperature gradient between the cold tip and superconducting coils satisfies the design but with little margin. Opportunities to reduce the gradient are identified.

Electrified aircraft propulsion↗

The dynamic characteristics of a turbo-rotor simulator supported on gas-lubricated foil bearings. Part 2: Operation with heating and thermal gradients

A high speed rotor, supported by gas-lubricated foil bearings, is free from self-excited whirl and displays no loss of load capacity when vibrated at frequency equal to the rotational speed. It is demonstrated that in addition to tolerance of geometrical imperfections, misalignment and foreign particles, the foil bearing performs well at elevated temperatures and accommodates appreciable temperature gradients. The foil bearing is endowed with superior wipe-wear characteristics and the flexibility of the foil accounts not only for the stability of the foil bearing, but also for its accommodation of, and compensation for, distortion, contamination, and contact.

Licht, L.↗

Atomic density effects on temperature characteristics and thermal transport at grain boundaries through a proper bin size selection

This study focuses on the proper characterization of temperature profiles across grain boundaries (GBs) in order to calculate the correct interfacial thermal resistance (ITR) and reveal the influence of GB geometries onto thermal transport. The solid-solid interfaces resulting from the orientation difference between the (001), (011), and (111) copper surfaces were investigated. Temperature discontinuities were observed at the boundary of grains due to the phonon mismatch, phonon backscattering, and atomic forces between dissimilar structures at the GBs. We observed that the temperature decreases gradually in the GB area rather than a sharp drop at the interface. As a result, three distinct temperature gradients developed at the GB which were different than the one observed in the bulk solid. This behavior extends a couple molecular diameters into both sides of the interface where we defined a thickness at GB based on the measured temperature profiles for characterization. Results showed dependence on the selection of the bin size used to average the temperature data from the molecular dynamics system. The bin size on the order of the crystal layer spacing was found to present an accurate temperature profile through the GB. We further calculated the GB thickness of various cases by using potential energy (PE) distributions which showed agreement with direct measurements from the temperature profile and validated the proper binning. The variation of grain crystal orientation developed different molecular densities which were characterized by the average atomic surface density (ASD) definition. Our results revealed that the ASD is the primary factor affecting the structural disorders and heat transfer at the solid-solid interfaces. Using a system in which the planes are highly close-packed can enhance the probability of interactions and the degree of overlap between vibrational density of states (VDOS) of atoms forming at interfaces, leading to a reduced ITR. Thus, an accurate understanding of thermal characteristics at the GB can be formulated by selecting a proper bin size.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Parameter space for magnetization effects in high-energy-density plasmas

Magnetic fields are well known to affect the evolution of fluids via the J × B force, where J is the current density and B is the magnetic field. This force leads to the influence of magnetic fields on hydrodynamics (magnetohydrodynamics). Magnetic fields are often neglected in modeling of high-energy-density plasmas, since J × B is very small compared with the plasma pressure gradients. However, many experiments lie in a separate part of parameter space where the plasma is indirectly affected via magnetization of the heat flux and charged particle transport. This is true even for initially unmagnetized plasmas, since misaligned density and temperature gradients can self-generate magnetic fields. By comparing terms in the induction equation, we go on to estimate the regions of parameter space where these self-generated fields are strong enough to affect the hydrodynamics.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Crump Geyser Exploration and Drilling Project. High Precision Geophysics and Detailed Structural Exploration and Slim Well Drilling

The Crump Geyser Exploration and Drilling Project – High Precision Geophysics and Detailed Structural Exploration and Slim Well Drilling ran from January 29, 2010 to September 30, 2013. During Phase 1 of the project, collection of all geophysical surveys was completed as outlined in the Statement of Project Objectives. In addition, a 5000-foot full sized exploration well was drilled by Ormat, and preexisting drilling data was discovered for multiple temperature gradient wells within the project area. Three dimensional modeling and interpretation of results from the geophysical surveys and drilling data gave confidence to move to the project into Phase 2 drilling. Geological and geophysical survey interpretations combined with existing downhole temperature data provided an ideal target for the first slim-hole drilled as the first task in Phase 2. Slim-hole 35-34 was drilled in September 2011 and tested temperature, lithology, and permeability along the primary range-bounding fault zone near its intersection with buried northwest-trending faults that have been identified using geophysical methods. Following analysis of the results of the first slim-hole 35-34, the second slim hole was not drilled and subsequent project tasks, including flowing differential self-potential (FDSP) surveys that were designed to detail the affect of production and injection on water flow in the shallow aquifer, were not completed. NGP sold the Crump project to Ormat in August 2014, afterwards, there was insufficient time and interest from Ormat available to complete the project objectives. NGP was unable to continue managing the award for a project they did not own due to liability issues and Novation of the award was not a viable option due to federal award timelines. NGP submitted a request to mutually terminate the award on February 18, 2015. The results of all of the technical surveys and drilling are included in this report. Fault interpretations from surface geology, aeromag, seismic, and gravity data sets are in good agreement, illustrating two or more major range-bounding faults and buried northwest trending faults. The intersections of these fault systems provide the primary targets for drilling.

15 GEOTHERMAL ENERGY↗

Blind Modeling Validation Exercises Using the Horizontal Dry Cask Simulator

The U.S. Department of Energy (DOE) established a need to understand the thermal-hydraulic properties of dry storage systems for commercial spent nuclear fuel (SNF) in response to a shift towards the storage of high-burnup (HBU) fuel (> 45 gigawatt days per metric ton of uranium, or GWd/MTU). This shift raises concerns regarding cladding integrity, which faces increased risk at the higher temperatures within spent fuel assemblies present within HBU fuel compared to low-burnup fuel (≤ 45 GWd/MTU). A dry cask simulator (DCS) was built at Sandia National Laboratories (SNL) in Albuquerque, New Mexico to produce validation-quality data that can be used to test the accuracy of the modeling used to predict cladding temperatures. These temperatures are critical to evaluating cladding integrity throughout the storage cycle of commercial spent nuclear fuel. A model validation exercise was previously carried out for the DCS in a vertical configuration. Lessons learned during the previous validation exercise have been applied to a new, blind study using a horizontal dry cask simulator (HDCS). Three modeling institutions – the Nuclear Regulatory Commission (NRC), Pacific Northwest National Laboratory (PNNL), and Empresa Nacional del Uranio, S.A., S.M.E. (ENUSA) – were granted access to the input parameters from the DCS Handbook, SAND2017-13058R, and results from a limited data set from the horizontal BWR dry cask simulator tests reported in the HDCS update report, SAND2019-11688R. With this information, each institution was tasked to calculate peak cladding temperatures and air mass flow rates for ten HDCS test cases. Axial as well as vertical and horizontal transverse temperature profiles were also calculated. These calculations were done using modeling codes (ANSYS/Fluent, STAR-CCM+, or COBRA-SFS), each with their own unique combination of modeling assumptions and boundary conditions. For this validation study, the ten test cases of the horizontal dry cask simulator were defined by three independent variables – fuel assembly decay heat (0.5 kW, 1 kW, 2.5 W, and 5 kW), internal backfill pressure (100 kPa and 800 kPa), and backfill gas (helium and air). The plots provided in Chapter 3 of this report show the axial, vertical, and horizontal temperature profiles obtained from the dry cask simulator experiments in the horizontal configuration and the corresponding models used to describe the thermal-hydraulic behavior of this system. The tables provided in Chapter 3 illustrate the closeness of fit of the model data to the experiment data through root mean square (RMS) calculations of the error in peak cladding temperatures (PCTs), PCT axial locations, axial temperature profiles, vertical and horizontal temperature profiles at two different axial locations, and air mass flow rates for the ten test cases, normalized by the experimental results. The model results are assigned arbitrary model numbers to retain anonymity. Due to the relatively flat axial temperature profiles, small temperature gradients resulted in large deviations of all models’ PCT axial location from the experimental PCT axial location. When the PCT axial location error is excluded in the calculation of the combined RMS of the normalized errors that considers PCT, the temperature profiles, and the air mass flow rates, the model data fits the experimental data to within 5%. When the vault information is excluded, the model data fits the experimental data to within 2.5%. An error analysis was developed further for one model, using the model and experimental uncertainties in each validation parameter to calculate validation uncertainties. The uncertainties for each parameter were used to define quantifiable validation criteria. For this analysis, the model was considered validated for a given comparison metric if the normalized error in that metric divided by the validation uncertainty was less than or equal to 1. When considering the combined RMS of the normalized errors of all metrics divided by their validation uncertainties, the model was found to have satisfied the criterion for model validation.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Implementation and Results of Extended-MHD Post-processing of xRAGE Simulations

Magnetic fields are known to affect the evolution of conducting fluids via the J× B force, where J is the current density and B is the magnetic field. Typically, J× B in high energy density plasmas (HEDP) systems is considered small compared to the plasma pressure gradients. However, many experiments lie in a part of the parameter space where the plasma is indirectly affected via magnetization of the heat flux and charged particle transport. This is true even for initially unmagnetized plasmas, since misaligned density and temperature gradients can self-generate the so-called Biermann magnetic fields.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗