Search NASA⌕ Search

SEARCH · Search NASA

Results for “Tracking error”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,189 records · Page 66

Topex orbit determination and gravity recovery using GPS data from repeat orbits

A covariance analysis is presented for a differential GPS-based technique for satellite tracking and gravity recovery to be demonstrated on Topex in the early 1990's. The technique employs data from an ensemble of repeat ground tracks to recover a unique satellite epoch state for each track and a set of invariant local gravity parameters common to all tracks. For satellites above about 800 km altitude, where gravity modeling is the dominant systematic error, averaging of random error over many arcs and adjustment of the gravity model reduces the final satellite position error. The local gravity parameters can then be used to produce a refined global gravity model. The analysis indicates that errors ranging from 5 to 8 cm in Topex altitude and 0.05 to 0.2 mgal for the gravity field can be achieved, depending on the number of repeat arcs used.

Wu, Jiun-Tsong↗

The limits of direct satellite tracking with GPS

Recent advances in high precision differential GPS-based satellite tracking can be usefully applied to the more conventional direct tracking of low earth satellites. To properly evaluate the limiting accuracy of direct GPS-based tracking, it is necessary to take full account of the correlations between the a priori errors in GPS states, Y-bias, and solar pressure parameters. These can be obtained by careful analysis of the GPS orbit determination process. When up-to-date assumptions are used in the analyses of GPS and user orbit solutions, it is found that submeter accuracy can be readily achieved for a user above 1000 km altitude, even when the user solution is obtained with data taken 12 hours after the data used in the GPS orbit solutions.

Bertiger, Willy I.↗

Ionospheric refraction effects on orbit determination using the orbit determination error analysis system

The influence of ionospheric refraction on orbit determination was studied through the use of the Orbit Determination Error Analysis System (ODEAS). The results of a study of the orbital state estimate errors due to the ionospheric refraction corrections, particularly for measurements involving spacecraft-to-spacecraft tracking links, are presented. In current operational practice at the Goddard Space Flight Center (GSFC) Flight Dynamics Facility (FDF), the ionospheric refraction effects on the tracking measurements are modeled in the Goddard Trajectory Determination System (GTDS) using the Bent ionospheric model. While GTDS has the capability of incorporating the ionospheric refraction effects for measurements involving ground-to-spacecraft tracking links, such as those generated by the Ground Spaceflight Tracking and Data Network (GSTDN), it does not have the capability to incorporate the refraction effects for spacecraft-to-spacecraft tracking links for measurements generated by the Tracking and Data Relay Satellite System (TDRSS). The lack of this particular capability in GTDS raised some concern about the achievable accuracy of the estimated orbit for certain classes of spacecraft missions that require high-precision orbits. Using an enhanced research version of GTDS, some efforts have already been made to assess the importance of the spacecraft-to-spacecraft ionospheric refraction corrections in an orbit determination process. While these studies were performed using simulated data or real tracking data in definitive orbit determination modes, the study results presented here were obtained by means of covariance analysis simulating the weighted least-squares method used in orbit determination.

Yee, C. P.↗

Bilevel shared control for teleoperators

A shared system is disclosed for robot control including integration of the human and autonomous input modalities for an improved control. Autonomously planned motion trajectories are modified by a teleoperator to track unmodelled target motions, while nominal teleoperator motions are modified through compliance to accommodate geometric errors autonomously in the latter. A hierarchical shared system intelligently shares control over a remote robot between the autonomous and teleoperative portions of an overall control system. Architecture is hierarchical, and consists of two levels. The top level represents the task level, while the bottom, the execution level. In space applications, the performance of pure teleoperation systems depend significantly on the communication time delays between the local and the remote sites. Selection/mixing matrices are provided with entries which reflect how each input's signals modality is weighted. The shared control minimizes the detrimental effects caused by these time delays between earth and space.

Hayati, Samad A.↗

Orbit Determination Support for the Microwave Anisotropy Probe (MAP)

NASA's Microwave Anisotropy Probe (MAP) was launched from the Cape Canaveral Air Force Station Complex 17 aboard a Delta II 7425-10 expendable launch vehicle on June 30, 2001. The spacecraft received a nominal direct insertion by the Delta expendable launch vehicle into a 185-km circular orbit with a 28.7deg inclination. MAP was then maneuvered into a sequence of phasing loops designed to set up a lunar swingby (gravity-assisted acceleration) of the spacecraft onto a transfer trajectory to a lissajous orbit about the Earth-Sun L2 Lagrange point, about 1.5 million km from Earth. Because of its complex orbital characteristics, the mission provided a unique challenge for orbit determination (OD) support in many orbital regimes. This paper summarizes the premission trajectory covariance error analysis, as well as actual OD results. The use and impact of the various tracking stations, systems, and measurements will be also discussed. Important lessons learned from the MAP OD support team will be presented. There will be a discussion of the challenges presented to OD support including the effects of delta-Vs at apogee as well as perigee, and the impact of the spacecraft attitude mode on the OD accuracy and covariance analysis.

Bauer, Frank↗

Analytic Guidance for the First Entry in a Skip Atmospheric Entry

This paper presents an analytic method to generate a reference drag trajectory for the first entry portion of a skip atmospheric entry. The drag reference, expressed as a polynomial function of the velocity, will meet the conditions necessary to fit the requirements of the complete entry phase. The generic method proposed to generate the drag reference profile is further simplified by thinking of the drag and the velocity as density and cumulative distribution functions respectively. With this notion it will be shown that the reference drag profile can be obtained by solving a linear algebraic system of equations. The resulting drag profile is flown using the feedback linearization method of differential geometric control as guidance law with the error dynamics of a second order homogeneous equation in the form of a damped oscillator. This approach was first proposed as a revisited version of the Space Shuttle Orbiter entry guidance. However, this paper will show that it can be used to fly the first entry in a skip entry trajectory. In doing so, the gains in the error dynamics will be changed at a certain point along the trajectory to improve the tracking performance.

Garcia-Llama, Eduardo↗

Further Characterization of an Active Clearance Control Concept

A new test chamber and precision hydraulic actuation system were incorporated into an active clearance control (ACC) test rig at NASA Glenn Research Center. Using the improved system, a fast-acting, mechanically-actuated, ACC concept was evaluated at engine simulated temperatures and pressure differentials up to 1140 F and 120 psig, on the basis of secondary seal leakage and kinematic controllability. During testing, the ACC concept tracked a simulated flight clearance transient profile at 1140 F, 120 psig, with a maximum error of only 0.0012 in. Comparison of average dynamic leakage of the system with average static leakage did not show significant differences between the two operating conditions. Calculated effective clearance values for the rig were approximately 0.0002 in. at 120 psig, well below the industry specified effective clearance threshold of 0.001 in.

Taylor, Shawn C.↗

Distributed Ground Sensor Fusion Based Object Tracking for Autonomous Advanced Air Mobility Operations

Autonomous operations are a crucial aspect in the context of Advanced Air Mobility and other emerging aviation markets. In order to enable this autonomy, an accurate and detailed understanding of the positions of the various vehicles in the air is necessary. Full localization independent of on-board sensors makes the system suitable for noncooperative vehicles. This paper focuses on the object tracking part that relies on distributed ground-based sensor fusion, considering specific properties and limitations of different sensor types. Results show satisfactory performance in nominal scenarios with full coverage. Dropouts of individual sensors affect the accuracy of the tracking results, which agrees with expectations for partial coverage, when full localization is not achievable anymore. Finally, a study is performed to identify which parameters have the largest impact on the fit error.

Autonomous↗

Effect Of Transition Density On Performance Of A DTTL

One estimates minimum transition density needed to limit symbol-error rate. Theoretical calculations and accompanying computer simulations provide numerical basis for specification of minimum data-transition density needed for adequate performance of radio receiver processing noisy signal containing non-return-to-zero (NRZ) stream of data symbols (bits). By use of digital-data-transition-tracking loop (DTTL), receiver strives to synchronize operation with data symbols. Performance of receiver in terms of ability to keep symbol-error rate (SER) in output of receiver below specified level depends on symbol signal-to-noise ratio (SSNR) of incoming signal and on degree of synchronization. Ability of DTTL to maintain synchronization depends partly on SSNR and partly on data-transition density.

Nguyen, Tien M.↗

Tracking magnetogram proper motions by multiscale regularization

Long uninterrupted sequences of solar magnetograms from the global oscillations network group (GONG) network and from the solar and heliospheric observatory (SOHO) satellite will provide the opportunity to study the proper motions of magnetic features. The possible use of multiscale regularization, a scale-recursive estimation technique which begins with a prior model of how state variables and their statistical properties propagate over scale. Short magnetogram sequences are analyzed with the multiscale regularization algorithm as applied to optical flow. This algorithm is found to be efficient, provides results for all the spatial scales spanned by the data and provides error estimates for the solutions. It is found that the algorithm is less sensitive to evolutionary changes than correlation tracking.

Jones, Harrison P.↗

Spacecraft system study: A study to define the impact of laser communication systems on their host spacecraft

The mutual influence of a laser communication system and its host spacecraft and the degree to which the mutual influence limited acquisition, tracking and pointing processes were investigated. A laser klink between a low earth orbiting (LEO) satellite and a geosynchronous earth orbiting (GEO) satellite was used as a baseline. The laser link between satellites was a generic channel transferring 500 Mbps data from the LEO to GEO using the GaAlAs laser as the laser light source. Major aspects of pointing and tracking with a satelliteborne optical system were evaluated including: (1) orbital aspects such as spacecraft relative motions, point ahead, and Sun snd Moon optical noise; (2) burst errors introduced by the electronic and optical noise levels; (3) servo system design and configurations, and the noise sources such as, sensor noise, base motion disturbances, gimbal friction torque noise; (4) an evaluation of the tracking and beacon link and the type of sensors used; (5) the function of the acquisition procedure and an evaluation of the sensors employed; and (6) an estimate of the size, weight and power needed for the satellite system.

Source record↗

Integrated Pointing and Signal Detector for Optical Receiver

A design concept for the receiver portion of a proposed free-space optical-communication terminal calls for integration of its communication and pointing detectors. As explained below, this would entail a departure from prior designs, in which pointing and communication detectors have been separate. As used here, communication detector denotes a single high-speed photodetector used for reception of a laser beam that has been modulated to convey information, while pointing detector denotes an array of photodetectors (typically, a quad-cell detector or a charge-coupled device) used in sensing the pointing error (the error in the aim of a receiver telescope, relative to the laser-beam axis). The pointing detector of this or any free-space optical-communication receiver is necessary for proper acquisition and tracking of the received laser beam. The suitably processed output of the pointing detector is fed back to a fine-steering mirror to reduce any pointing error and thereby maintain optimum reception. Heretofore, it has been common practice to pass the incoming laser beam through a beam splitter that sends about 10 percent of the beam power to a pointing detector and the rest to a separate communication detector, as illustrated in the upper part of the figure. One disadvantage of this is that because only 10 percent of the received signal power is available for use by the pointing detector, the signal-to-noise ratio (SNR) at the pointing detector is lower than it otherwise would be. The performance of the pointing detector is correspondingly limited. Another disadvantage is that the alignment between the communication and pointing detectors is critical and must be ensured by means of a calibration procedure. According to the proposal, there would be no beam splitter. The communication and pointing detectors would be positioned coaxially in the same focal plane, as shown in the lower part of the figure: the communication detector would occupy the central part of the focal plane, while the pointing detector would occupy the surrounding area. This arrangement would inherently ensure the proper alignment of the detectors with each other.

Britcliffe, Michael↗

Media Calibration in the Deep Space Network: A Status Report

A new media calibration system (MCS) has been implemented at the Goldstone complex of the DSN (Deep Space Network). It is intended to calibrate the delay of radio signals imposed by the neutral atmosphere. The system provides periodic measurements of both the static dry and fluctuating wet components of this delay. In particular, the system will calibrate the fluctuations in line of sight path delay due to atmospheric water vapor that we believe will dominate the error budget for several radio science and radio astronomy experiments. We have compared two of these media calibration systems with a connected element interferometer on a 21 km baseline. In this report we describe a total of 30 observations in which a radio source was tracked for an hour or more and the delay residuals then calibrated using the MCS. The accuracy of the comparison appears to be limited by systematic errors in the interferometer, which are under investigation. However, our results do indicate that the MCS can meet or exceed the two-way Allan standard deviation specification of 1.5 x 10( exp -15) on time scales of 2,000 - 10,000 sec, as required by the Cassini GWE (Gravitational Wave Experiment) for two way Doppler tracking.

Naudet, Charles J.↗

SU-G-JeP1-02: A New Intra-Fractional Prostate Motion Tracking Method in Volumetric Modulated Arc Therapy (VMAT) Via 2D/3D Registration

Purpose: Intra-fractional prostate motion leads uncertainty on delivered dose in radiotherapy and may cause significant dose deviation from the planned dose distribution. This is especially a concern in scenarios with a high dose per fraction and hence a long delivery time, e.g. stereotactic body radiotherapy. Knowledge about intra-fractional prostate motion is valuable to address this problem, e.g. by reconstructing delivered dose and performing adaptation. This study proposes a new approach to determine intra-fractional prostate motion in VMAT via 2D/3D maker registration. Methods: At our institution, each patient has three markers implanted in the prostate. During treatment delivery, kV triggered images were taken every three seconds to acquire 2D projection of 3D anatomy at the direction orthogonal to the therapeutic beam. Projected marker locations were identified on each projection image using template matching with geometric constraints. 3D prostate translation and rotation for each triggered image were obtained by solving an optimization problem, such that the calculated marker locations match the measured ones. Inter-image motion smoothness was employed as a constraint. We tested this method in simulation studies with five realistic prostate motion trajectories acquired via Calypso and in real phantom experiments. Results: For the simulation case, the motion range for these patients was 0.5∼6.0 mm. Root mean square (RMS) error of calculated motion along left-right (LR), anterior-posterior (AP) and cranial-caudal (CC) directions were 0.26mm, 0.36mm, and 0.016mm, respectively. The motion range in the phantom study along LR, AP, and CC directions were 15mm, 20mm and 10mm. The mean RMS errors along these directions were 1.99mm, 1.37mm and 0.22mm. Conclusion: A new prostate motion tracking algorithm based on kV triggered images has been developed and validated. Clinically acceptable accuracy has been achieved.

60 APPLIED LIFE SCIENCES↗

Waypoint Following Dynamics of a Quaternion Error Feedback Attitude Control System

Closed-loop attitude steering can be used to implement alternative attitude maneuvers by using a conventional attitude control system to track a non-standard attitude profile sampled as a series of sequential commands. The idea has been employed in practice to perform zero-propellant maneuvers on the International Space Station and minimum time maneuvers on NASA’s TRACE space telescope. A challenge for operational implementation of the idea is the finite capacity of a space vehicle’s command storage buffer. One approach to mitigate the problem is to downsample-and-hold the attitude commands so that the attitude control system to follows a set of waypoints. This paper explores the waypoint following dynamics of a quaternion error feedback control law for downsample-and-hold. It is shown that downsample-and-hold induces a ripple between downsamples that causes the satellite angular rate to significantly overshoot the desired limit. Analysis in the z-domain is carried out in order to understand the phenomenon. An interpolating Chebyshev-type filter is proposed that allows attitude commands to be encoded in terms of a small set of filter coefficients. Using the interpolating filter, commands can be issued at the ACS rate but with significantly reduced memory requirements. The attitude control system of NASA’s Lunar Reconnaissance Orbiter is used as an example to illustrate the behavior of a practical attitude control system.

Mark Karpenko↗

Polarization mismatch errors in radio phase interferometers.

An analysis is presented which deals with the effects of polarization mismatch errors on the accuracy of a phase interferometer used for position location of unknown emitters relative to known calibration emitters. Closed-form expressions for the induced phase difference between interferometer antennas are derived for several combinations of receiving and transmitting antenna polarizations. Errors contributed by mechanical misalignment between antennas, as well as effects of power loss attributable to polarization mismatch, are also considered. The analysis leads to the conclusion that circularly polarized interferometer and transmitter antennas are best suited for the position location application, if it is assumed that polarization tracking of the interferometer antennas is not available. It is shown that a reasonable amount of ellipticity can be tolerated before the phase error becomes significant.

Muehldorf, E. I.↗

An integrated model-driven method for in-treatment upper airway motion tracking using cine MRI in head and neck radiation therapy

Purpose: For the first time, MRI-guided radiation therapy systems can acquire cine images to dynamically monitor in-treatment internal organ motion. However, the complex head and neck (H&N) structures and low-contrast/resolution of on-board cine MRI images make automatic motion tracking a very challenging task. In this study, the authors proposed an integrated model-driven method to automatically track the in-treatment motion of the H&N upper airway, a complex and highly deformable region wherein internal motion often occurs in an either voluntary or involuntary manner, from cine MRI images for the analysis of H&N motion patterns. Methods: Considering the complex H&N structures and ensuring automatic and robust upper airway motion tracking, the authors firstly built a set of linked statistical shapes (including face, face-jaw, and face-jaw-palate) using principal component analysis from clinically approved contours delineated on a set of training data. The linked statistical shapes integrate explicit landmarks and implicit shape representation. Then, a hierarchical model-fitting algorithm was developed to align the linked shapes on the first image frame of a to-be-tracked cine sequence and to localize the upper airway region. Finally, a multifeature level set contour propagation scheme was performed to identify the upper airway shape change, frame-by-frame, on the entire image sequence. The multifeature fitting energy, including the information of intensity variations, edge saliency, curve geometry, and temporal shape continuity, was minimized to capture the details of moving airway boundaries. Sagittal cine MR image sequences acquired from three H&N cancer patients were utilized to demonstrate the performance of the proposed motion tracking method. Results: The tracking accuracy was validated by comparing the results to the average of two manual delineations in 50 randomly selected cine image frames from each patient. The resulting average dice similarity coefficient (93.28% ± 1.46%) and margin error (0.49 ± 0.12 mm) showed good agreement between the automatic and manual results. The comparison with three other deformable model-based segmentation methods illustrated the superior shape tracking performance of the proposed method. Large interpatient variations of swallowing frequency, swallowing duration, and upper airway cross-sectional area were observed from the testing cine image sequences. Conclusions: The proposed motion tracking method can provide accurate upper airway motion tracking results, and enable automatic and quantitative identification and analysis of in-treatment H&N upper airway motion. By integrating explicit and implicit linked-shape representations within a hierarchical model-fitting process, the proposed tracking method can process complex H&N structures and low-contrast/resolution cine MRI images. Future research will focus on the improvement of method reliability, patient motion pattern analysis for providing more information on patient-specific prediction of structure displacements, and motion effects on dosimetry for better H&N motion management in radiation therapy.

60 APPLIED LIFE SCIENCES↗

Technical Note: A novel leaf sequencing optimization algorithm which considers previous underdose and overdose events for MLC tracking radiotherapy

Purpose: Multileaf collimator (MLC) tracking radiotherapy is complex as the beam pattern needs to be modified due to the planned intensity modulation as well as the real-time target motion. The target motion cannot be planned; therefore, the modified beam pattern differs from the original plan and the MLC sequence needs to be recomputed online. Current MLC tracking algorithms use a greedy heuristic in that they optimize for a given time, but ignore past errors. To overcome this problem, the authors have developed and improved an algorithm that minimizes large underdose and overdose regions. Additionally, previous underdose and overdose events are taken into account to avoid regions with high quantity of dose events. Methods: The authors improved the existing MLC motion control algorithm by introducing a cumulative underdose/overdose map. This map represents the actual projection of the planned tumor shape and logs occurring dose events at each specific regions. These events have an impact on the dose cost calculation and reduce recurrence of dose events at each region. The authors studied the improvement of the new temporal optimization algorithm in terms of the L1-norm minimization of the sum of overdose and underdose compared to not accounting for previous dose events. For evaluation, the authors simulated the delivery of 5 conformal and 14 intensity-modulated radiotherapy (IMRT)-plans with 7 3D patient measured tumor motion traces. Results: Simulations with conformal shapes showed an improvement of L1-norm up to 8.5% after 100 MLC modification steps. Experiments showed comparable improvements with the same type of treatment plans. Conclusions: A novel leaf sequencing optimization algorithm which considers previous dose events for MLC tracking radiotherapy has been developed and investigated. Reductions in underdose/overdose are observed for conformal and IMRT delivery.

61 RADIATION PROTECTION AND DOSIMETRY↗