Search NASA⌕ Search

SEARCH · Search NASA

Results for “Validation Methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,189 records · Page 66

Evaluation of an aerodynamic-load prediction method on a STOL fighter configuration

A three-dimensional panel method was used to compute the aerodynamic loads on a large-scale, powered wind tunnel model. The size of the computation grid was selected such that turnaround times, on present computers remained satisfactory. With this constraint, the STOL aircraft configuration was modeled and the capabilities and limitations of the prediction method were investigated. After this study, a similar numerical model was established for a forward-swept-wing aircraft configuration which is planned for large-scale, low-speed testing. The resulting aerodynamic-load predictions are discussed and will be utilized, together with the future experimental results, to obtain a broader validation of this method as well as to reduce the necessary size of the matrix of the test parameters.

Katz, J.↗

Full-Field Reconstruction of Structural Deformations and Loads from Measured Strain Data on a Wing Using the Inverse Finite Element Method

A study was undertaken to investigate the measurement of wing deformation and internal loads using measured strain data. Future aerospace vehicle research depends on the ability to accurately measure the deformation and internal loads during ground testing and in flight. The approach uses the inverse Finite Element Method (iFEM). The iFEM is a robust, computationally efficient method that is well suited for real-time measurement of real-time structural deformation and loads. The method has been validated in previous work, but has yet to be applied to a large-scale test article. This work is in preparation for an upcoming loads test of a half-span test wing in the Flight Loads Laboratory at the National Aeronautics and Space Administration Armstrong Flight Research Center (Edwards, California). The method has been implemented into an efficient MATLAB® (The MathWorks, Inc., Natick, Massachusetts) code for testing different sensor configurations. This report discusses formulation and implementation along with the preliminary results from a representative aerospace structure. The end goal is to investigate the modeling and sensor placement approach so that the best practices can be applied to future aerospace projects.

Finite element↗

Comparison of dose estimates using the buildup-factor method and a Baryon transport code (BRYNTRN) with Monte Carlo results

Continuing efforts toward validating the buildup factor method and the BRYNTRN code, which use the deterministic approach in solving radiation transport problems and are the candidate engineering tools in space radiation shielding analyses, are presented. A simplified theory of proton buildup factors assuming no neutron coupling is derived to verify a previously chosen form for parameterizing the dose conversion factor that includes the secondary particle buildup effect. Estimates of dose in tissue made by the two deterministic approaches and the Monte Carlo method are intercompared for cases with various thicknesses of shields and various types of proton spectra. The results are found to be in reasonable agreement but with some overestimation by the buildup factor method when the effect of neutron production in the shield is significant. Future improvement to include neutron coupling in the buildup factor theory is suggested to alleviate this shortcoming. Impressive agreement for individual components of doses, such as those from the secondaries and heavy particle recoils, are obtained between BRYNTRN and Monte Carlo results.

Shinn, Judy L.↗

Battery Charge Curve Prediction via Feature Extraction and Supervised Machine Learning

Real-time onboard state monitoring and estimation of a battery over its lifetime is indispensable for the safe and durable operation of battery-powered devices. In this study, a methodology to predict the entire constant-current cycling curve with limited input information that can be collected in a short period of time is developed. A total of 10 066 charge curves of LiNiO 2 -based batteries at a constant C-rate are collected. With the combination of a feature extraction step and a multiple linear regression step, the method can accurately predict an entire battery charge curve with an error of < 2% using only 10% of the charge curve as the input information. The method is further validated across other battery chemistries (LiCoO 2 -based) using open-access datasets. The prediction error of the charge curves for the LiCoO 2 -based battery is around 2% with only 5% of the charge curve as the input information, indicating the generalization of the developed methodology for predicting battery cycling curves. The developed method paves the way for fast onboard health status monitoring and estimation for batteries during practical applications.

25 ENERGY STORAGE↗

An O(N logN) multi-layer boundary element method for direct computation of sound propagation in shallow water environments

Direct three-dimensional (3D) numerical simulations of acoustic fields in range-dependent shallow water environments remains a challenge due to environmental complexities and large computational cost.We develop an efficient 3D boundary element method (BEM) for shallow water acoustic propagation which utilizes a Pre-corrected Fast Fourier Transform (PFFT) approach to reduce the computational effort from O ( N 2~3 ) to O ( N log N ) where N is the total number of boundary unknowns. To account for inhomogeneous media, the method allows for arbitrary number of coupled multi-layer BEM sub-domains. With O ( N log N ) efficiency and the use of massively parallel high-performance computing platforms, we are able to conduct multi-layer 3D direct simulations of low-mid frequency acoustics over kilometer ranges. Furthermore we perform extensive validations of the method and provide two shallow water waveguide examples benchmarked against theoretical solutions. To illustrate the efficacy and usefulness of the PFFT-BEM method, we perform 3D large-scale direct simulations to assess the performance of two established canonical models: axisymmetric coupled mode model for 3D seamount; and Kirchhoff approximation and perturbation theory for 3D rough surface scattering.

42 ENGINEERING↗

Integrated Oxygen Flow Meter/Heat Exchanger for Portable Life Support Systems

Space suits for future exploration missions will have multi-mission goals with new and challenging requirements for the portable life support system (PLSS). In particular, the space suit ventilation loop requires cooling and flow measurement components that must meet specifications that go well beyond the capabilities of the components used for the existing Extravehicular Mobility Unit. The flow meter must have high measurement accuracy over a wide flow range, compatibility with pure oxygen, low pressure losses, and very compact size. The heat exchanger that cools the ventilation loop must be built from materials that are compatible with the liquid cooling loop, and it must provide efficient gas cooling in a small package across conditions ranging from normal suit pressure to elevated pressure. This paper describes the development of a novel device that combines the flow measurement and cooling functions in a single, compact flow meter/heat exchanger (FMHX). We have developed design methods that enable us to assess trade-offs, optimize performance, and specify the design of an FMHX that meets the requirements and constraints for operation in future PLSSs. We used empirical design correlations combined with computational fluid dynamics analysis to design the FMHX design. Data from tests of a proof-of-concept FMHX validate the design methods and show that the device meets all design requirements. We used the results from these tests to refine the design parameters and predict performance of an optimized, prototype FMHX.

Izenson, Michael G.↗

Validation of SE-EPI-based T2 mapping for characterization of prostate cancer: a new method compared with the traditional CPMG method

Purpose: We aim to compare the results of spin echo–echo planar imaging (SE-EPI)-based T2 mapping with those of the conventional Carr–Purcell–Meiboom–Gill (CPMG) method and to investigate the potential validity of SE-EPI-T2 mapping for the characterization of prostate cancer (PCa). Methods: Our retrospective study included 42 PCa patients and 42 noncancer patients who underwent 3.0T MRI with b values ranging from 0 to 2000 s/mm{sup 2} and echo times (TEs) ranging from 32 to 100 ms before biopsies. Bland–Altman analysis was used to compare the agreement between the two methods. The correlations between CPMG-T2 values and SE-EPI-T2 values at different b values were determined by Spearman’s rho analysis or Pearson analysis. The Mann–Whitney U test and two-sample t tests were used to analyze the differences between the cancerous and noncancerous groups. Results: Substantial agreement regarding the measurements was observed between the two methods. The average correlation between the CPMG-T2 values and SE-EPI-T2 values was moderate and positive, and the best correlations were found at b = 200 s/mm{sup 2} in the noncancer group (r = 0.557, P = 0.000) and at b = 100 s/mm{sup 2} in the cancer group (r = 0.537, P = 0.000). In addition, statistically significant differences were found between the noncancer and cancer groups in T2 values and ADC values (diff TEs) (P = 0.000). Conclusions: Substantial agreement in the measurements was found between the SE-EPI method and CPMG method. SE-EPI-based T2 mapping has potential clinical value for the prostate and can be considered an alternative to the traditional CPMG-T2 mapping method.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Development of a BISON validation case for the TRISO transient irradiations in NSRR using effective heat capacity methods

The current tristructural isotropic (TRISO) fuel assessment and validation database in BISON primarily covers steady- state irradiation and high-temperature furnace testing. Transient assessment cases are potentially needed to support U.S. industry efforts in designing and deploying commercial reactors using TRISO fuels. Historical transient tests in- volving TRISO fuels used highly conservative conditions compared to the typical high-temperature gas-cooled reactor accident scenarios. Despite this, modeling historical transient tests is fundamental for evaluating BISON’s predictive capabilities, adapting material properties for high-temperature and high-particle-power regimes, and developing a sys- tematic validation approach for TRISO transient applications. This work developed a 1D model of transient experiments carried out at the Nuclear Safety Research Reactor using BISON. BISON’s predictions of energy deposition, UO 2 melting onset, and molten volume fractions are compared against experimental measurements. Melting was modeled using an effective specific heat capacity model for UO 2 . We found that BISON’s predictions are in reasonable agreement with experimental data for low-energy-deposition cases, and that BISON overpredicts melting at higher energy depositions. We also discuss the potential causes of discrepancies between the simulated and measured results and propose ways to further develop the model. Although these simulations used conservative conditions compared to those expected for actual TRISO-fueled reactors, they extended the range of conditions reflected in the data in the existing BISON database for TRISO fuels.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Rapid 235 U/ 238 U determination by matrix assisted ionization–time-of-flight mass spectrometry

Matrix-assisted ionization (MAI) of inorganic analytes is a nascent research domain that holds promise for rapid, potentially facility-deployable analytical applications. Here, we present results of MAI uranium isotopic analysis ( 235 U/ 238 U) obtained on the timescale of minutes utilizing simple sample preparation and an ambient ionization time-of-flight mass spectrometer (ToF MS). Experimental MAI-ToF MS characterization of uranium Certified Reference Materials (CRMs) was used to establish method calibration and validate quantitative 235 U/ 238 U determination spanning depleted, natural, and low-enriched uranium isotopic compositions. Secondary standard analyses with total uranium mass loadings of 5–500 ng per analysis yield accurate calibrated 235 U/ 238 U results and relative uncertainties of 4.7–17.2% (approx. ±95% confidence level), with weighted-mean uncertainties approaching 1.5%. This method permits accurate determination of uranium isotopic composition in a sample with uranium content as low as 200 pg for equal atom 235 U: 238 U. Instrument detection limits constrain the minimum uranium mass required to identify the presence of highly enriched uranium (HEU ≥20% 235 U) as only 500 pg using the method presented here. MAI-ToF MS quantitation of relatively extreme isotope ratios ( 235 U/ 238 U ≤ 0.01) is limited by detection of minor 235 U (LoD 100 pg 235 U/analysis ≈ 10 ng total U/analysis), and subsequent method optimization is anticipated to further reduce these limits. These findings underscore the potential of MAI-ToF MS for isotopic characterization of uranium and other inorganic species for both basic and applied science.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-Resolution Imaging of Supraglacial Hydrological Features on the Greenland Ice Sheet with NASA’s Airborne Topographic Mapper (ATM) Instrument Suite

Seasonal meltwater pools on the surface of the Greenland Ice Sheet (GrIS) during late spring and summer in lakes on the surface and transforms the ice sheet's surface into a wet environment in the ablation zone below the equilibrium line. These supraglacial lakes in topographic lows on the ice surface are connected by a dendritic pattern of meandering streams and channels that together form a hydrological system consisting of supra-, en-, and subglacial components. Here, we use lidar data from NASA's Airborne Topographic Mapper (ATM) instrument suite and high-resolution optical imagery collected as part of Operation IceBridge (OIB) in spring 2019 over the GrIS to develop methods for the study of supraglacial hydrological features. While airborne surveys have a limited temporal and spatial coverage compared to imaging spaceborne sensors, their high footprint density and high-resolution imagery reveal a level of detail that is currently not obtainable from spaceborne measurements. The accuracy and resolution of airborne measurements complement spaceborne measurements, can support calibration and validation of spaceborne methods, and provide information necessary for high-resolution process studies of the supraglacial hydrological system on the GrIS that currently cannot be achieved from spaceborne observations alone.

ATM↗

Deep eutectic solvents as green and sustainable diluents in headspace gas chromatography for the determination of trace level genotoxic impurities in pharmaceuticals

Genotoxic impurities (GTIs) are potential carcinogens that need to be controlled down to ppm or lower concentration levels in pharmaceuticals under strict regulations. The static headspace gas chromatography (HS-GC) coupled with electron capture detection (ECD) is an effective approach to monitor halogenated and nitroaromatic genotoxins. Deep eutectic solvents (DESs) possess tunable physico-chemical properties and low vapor pressure for HS-GC methods. In this study, zwitterionic and non-ionic DESs have been used for the first time to develop and validate a sensitive analytical method for the analysis of 24 genotoxins at sub-ppm concentrations. Compared to non-ionic diluents, zwitterionic DESs produced exceptional analytical performance and the betaine: 7 (1,4- butane diol) DES outperformed the betaine: 5 (1,4-butane diol) DES. Limits of detection (LOD) down to the 5-ppb concentration level were achieved in DESs. Wide linear ranges spanning over 5 orders of magnitude (0.005–100 µg g –1 ) were obtained for most analytes with exceptional sensitivities and high precision. The method accuracy and precision were validated using 3 commercially available drug substances and excellent recoveries were obtained. Finally, this study broadens the applicability of HS-GC in the determination of less volatile GTIs by establishing DESs as viable diluent substitutes for organic solvents in routine pharmaceutical analysis.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Too Good to Be True? Evaluation of Colonoscopy Sensitivity Assumptions Used in Policy Models

Background: Models can help guide colorectal cancer screening policy. Although models are carefully calibrated and validated, there is less scrutiny of assumptions about test performance. Methods: We examined the validity of the CRC-SPIN model and colonoscopy sensitivity assumptions. Standard sensitivity assumptions, consistent with published decision analyses, assume sensitivity equal to 0.75 for diminutive adenomas (<6 mm), 0.85 for small adenomas (6–10 mm), 0.95 for large adenomas (≥10 mm), and 0.95 for preclinical cancer. We also selected adenoma sensitivity that resulted in more accurate predictions. Targets were drawn from the Wheat Bran Fiber study. In the study, we examined how well the model predicted outcomes measured over a three-year follow-up period, including the number of adenomas detected, the size of the largest adenoma detected, and incident colorectal cancer. Results: Using standard sensitivity assumptions, the model predicted adenoma prevalence that was too low (42.5% versus 48.9% observed, with 95% confidence interval 45.3%–50.7%) and detection of too few large adenomas (5.1% versus 14.% observed, with 95% confidence interval 11.8%–17.4%). Predictions were close to targets when we set sensitivities to 0.20 for diminutive adenomas, 0.60 for small adenomas, 0.80 for 10- to 20-mm adenomas, and 0.98 for adenomas 20 mm and larger. Conclusions: Colonoscopy may be less accurate than currently assumed, especially for diminutive adenomas. Alternatively, the CRC-SPIN model may not accurately simulate onset and progression of adenomas in higher-risk populations. Impact: Misspecification of either colonoscopy sensitivity or disease progression in high-risk populations may affect the predicted effectiveness of colorectal cancer screening. When possible, decision analyses used to inform policy should address these uncertainties.

60 APPLIED LIFE SCIENCES↗

Efficient general method for numerically modeling laser pulse propagation, overlap, and lifetime effects in amplifiers

An efficient numerical time-dependent general method is developed to address incoherent pulse overlap and lifetime effects in laser amplifiers. The alternating propagation-population laser energetics method (APPLE) has been validated against a semi-discrete coupled rate equation numerical method (SDRE) and analytic formalisms in bounding cases. APPLE is based on decoupled rates applied to a time-dependent framework where both space-time-dependent populations and pulse energetics are consistently updated in each time step. A significant advantage of APPLE lies in its conceptual simplicity, ease of implementation, and relatively small computational cost. SDRE tracks the populations through coupled rates and uses the method of lines to discretize the hyperbolic partial differential transport equations allowing for use of ordinary differential equation solvers. With reasonably sized mesh, we report both energetic and power pulse shape relative differences on the order of one percent between the models over a large range of initial conditions.

47 OTHER INSTRUMENTATION↗

Nonlinear Aeroelastic Analysis Using a Time-Accurate Navier-Stokes Equations Solver

A method to simulate limit cycle oscillation (LCO) due to control surface freeplay using a modified CFL3D, a time-accurate Navier-Stokes computational fluid dynamics (CFD) analysis code with structural modeling capability, is presented. This approach can be used to analyze aeroelastic response of aircraft with structural behavior characterized by nonlinearity in the force verses displacement curve. A limited validation of the method, using very low Mach number experimental data for a three-degrees-of-freedom (pitch/plunge/flap deflection) airfoil model with flap freeplay, is also presented.

Kuruvila, Geojoe↗

Improved Calibration of Modeled Discharge and Storage Change in the Atchafalaya Floodplain Using SAR Interferometry

This study focuses on the feasibility of using SAR interferometry to support 2D hydrodynamic model calibration and provide water storage change in the floodplain. Two-dimensional (2D) flood inundation modeling has been widely studied using storage cell approaches with the availability of high resolution, remotely sensed floodplain topography. The development of coupled 1D/2D flood modeling has shown improved calculation of 2D floodplain inundation as well as channel water elevation. Most floodplain model results have been validated using remote sensing methods for inundation extent. However, few studies show the quantitative validation of spatial variations in floodplain water elevations in the 2D modeling since most of the gauges are located along main river channels and traditional single track satellite altimetry over the floodplain are limited. Synthetic Aperture Radar (SAR) interferometry recently has been proven to be useful for measuring centimeter-scale water elevation changes over the floodplain. In the current study, we apply the LISFLOOD hydrodynamic model to the central Atchafalaya River Basin, Louisiana, during a 62 day period from 1 April to 1 June 2008 using two different calibration schemes for Manning's n. First, the model is calibrated in terms of water elevations from a single in situ gauge that represents a more traditional approach. Due to the gauge location in the channel, the calibration shows more sensitivity to channel roughness relative to floodplain roughness. Second, the model is calibrated in terms of water elevation changes calculated from ALOS PALSAR interferometry during 46 days of the image acquisition interval from 16 April 2008 to 1 June 2009. Since SAR interferometry receives strongly scatters in floodplain due to double bounce effect as compared to specular scattering of open water, the calibration shows more dependency to floodplain roughness. An iterative approach is used to determine the best-fit Manning's n for the two different calibration approaches. Results suggest similar floodplain roughness but slightly different channel roughness. However, application of SAR interferometry provides a unique view of the floodplain flow gradients, not possible with a single gauge calibration. These gradients, allow improved computation of water storage change over the 46-day simulation period. Overall, the results suggest that the use of 2D SAR water elevation changes in the Atchafalaya basin offers improved understanding and modeling of floodplain hydrodynamics.

Jung, Hahn Chul↗

Risk considerations for autonomy software

This paper summarizes key findings related to methods for the risk considerations of autonomy software. Existing methods for Verification and Validation (V&V) of autonomy software are summarized and a method for the assurance of autonomy software is suggested and demonstrated on a command execution use case. Risk and reliability are defined in the context of autonomy and an approach for risk assessment of autonomy is presented using an example use case. Key insights regarding areas of uncertainty for autonomy are provided, along with a suggested architecture for the systematic consideration of reliability within the context of a given autonomous planner.

Meshkat, Leila↗

On-Orbit Prospective Echocardiography on International Space Station

A number of echocardiographic research projects and experiments have been flown on almost every space vehicle since 1970, but validation of standard methods and the determination of Space Normal cardiac function has not been reported to date. Advanced Diagnostics in Microgravity (ADUM) -remote guided echocardiographic technique provides a novel and effective approach to on-board assessment of cardiac physiology and structure using a just-in-time training algorithm and real-time remote guidance aboard the International Space Station (ISS). The validation of remotely guided echocardiographic techniques provides the procedures and protocols to perform scientific and clinical echocardiography on the ISS and the Moon. The objectives of this study were: 1.To confirm the ability of non-physician astronaut/cosmonaut crewmembers to perform clinically relevant remotely guided echocardiography using the Human Research Facility on board the ISS. 2.To compare the preflight, postflight and in-flight echocardiographic parameters commonly used in clinical medicine.

Hamilton, Douglas R.↗

DeepONet-grid-UQ: A trustworthy deep operator framework for predicting the power grid’s post-fault trajectories

This paper proposes a novel data-driven method for the reliable prediction of the power grid’s post-fault trajectories, i.e., the power grid’s dynamic response after a disturbance or fault. Here, the proposed method is based on the recently proposed concept of Deep Operator Networks (DeepONets). Unlike traditional neural networks that learn to approximate functions, DeepONets are designed to approximate nonlinear operators, i.e., mappings between infinite-dimensional spaces. Under this operator framework, we design a novel and efficient DeepONet that (i) takes as inputs the trajectories collected before and during the fault and (ii) outputs the predicted post-fault trajectories. In addition, we endow our method with the much-needed ability to balance efficiency with reliable/trustworthy predictions via uncertainty quantification. To this end, we propose and compare two novel methods that enable quantifying the predictive uncertainty. First, we propose a Bayesian DeepONet (B-DeepONet) that uses stochastic gradient Hamiltonian Monte-Carlo to sample from the posterior distribution of the DeepONet trainable parameters. Then, we design a Probabilistic DeepONet (Prob-DeepONet) that uses a probabilistic training strategy to enable quantifying uncertainty at virtually no extra computational cost. Finally, we validate the proposed methods’ predictive power and uncertainty quantification capability using the New York-New England power grid model.

24 POWER TRANSMISSION AND DISTRIBUTION↗