Search NASA⌕ Search

SEARCH · Search NASA

Results for “Workflow”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,189 records · Page 66

The Artificial Scientist: in-Transit Machine Learning of Plasma Simulations

Large-scale simulations or scientific experiments produce petabytes of data per run. This poses massive challenges for I/O and storage when scientific analysis workflows are run manually offline. Unsupervised deep learning-based techniques to extract patterns and non-linear relations from these large amounts of data provide a way to build scientific understanding from raw data, reducing the need for manual pre-selection of analysis steps, but require exascale compute and memory to process the full dataset available. In this paper, we demonstrate a heterogeneous streaming workflow in which plasma simulation data is streamed directly to a Machine Learning (ML) application training a model on the simulation data in-transit, completely circumventing the capacity-constrained filesystem bottleneck. This workflow employs openPMD to provide a high level interface to describe scientific data and also uses ADIOS2, to transfer volumes of data that exceed the capabilities of the filesystem. We employ experience replay to avoid catastrophic forgetting in learning from this non-steady state process in a continual manner and adapt it to improve model convergence while learning in-transit. As a proof-of-concept, we approach the ill-posed inverse problem of predicting particle dynamics from radiation in a particle-incell (PIConGPU) simulation of the Kelvin-Helmholtz instability (KHI). We detail hardware-software co-design challenges as we scale PIConGPU to full Frontier, the Top-1 system as of June 2024 Top500 list.

Kelling, Jeffrey [Helmholtz-Zentrum Dresden Rossen↗

DICER: Data Intensive Computing Environment and Runtime for Evaluating Unprecedented Scale of Geospatial-Temporal Human Mobility Data

With the significant increase in sources and volume of human mobility data through commercial data vendors as well as microsimulation of cities, the scale of geospatial-temporal data to analyze and assess for mobility characterization has grown to the level of Big Data. There are mobility related commercial organizations deploying scalable computing, but often the system architecture, workflow, and intermediate processing components are not fully disclosed in relevant scope. Current research literature has a notable lack of studies demonstrating architectures and workflows for human mobility analytics that are implemented on a TeraByte scale of geospatial-temporal data. In this context, this paper presents a hyperscale-level system solution named DICER (Data Intensive Computing Environment and Runtime) for processing and analytics of geospatial-temporal data at big data scale. Although the cluster computing architecture of DICER with Apache Spark job running on Kubernetes cluster is not new, there are innovations in the workflow, hierarchical processing logic, and a wide range of intermediate preprocessing and mobility metrics calculation. We have performed case studies to validate the effectiveness of DICER system solution by performing detailed analytics and assessment of human mobility microsimulation output at three different scopes and scale, including a usecase with 16.97 TeraByte and 259.2 Billion rows of data. In addition, we have presented another case study of utilizing DICER to perform the same mobility processing and comparative analytics on large-scale commercially available geospatial-temporal data. All these case studies validate the efficiency and usefulness of DICER in computing population mobility characteristics from geospatial-temporal trajectory data at an unprecedented scale (not only just data volume, but also combination of: number of user entities, temporal frequency, spatial resolution, data duration).

De, Debraj↗

Data Provenance Hybridization Supporting Extreme-Scale Scientific WorkflowApplications

As high performance computing (HPC) infrastructures continue to grow in capability and complexity, so do the applications that they serve. HPC and distributed-area computing (DAC) (e.g. grid and cloud) users are looking increasingly toward workflow solutions to orchestrate their complex application coupling, pre- and post-processing needs To gain insight and a more quantitative understanding of a workflow’s performance our method includes not only the capture of traditional provenance information, but also the capture and integration of system environment metrics helping to give context and explanation for a workflow’s execution. In this paper, we describe IPPD’s provenance management solution (ProvEn) and its hybrid data store combining both of these data provenance perspectives.

provenance↗

Understanding data motion in the modern HPC data center

The utilization and performance of storage, compute, and network resources within HPC data centers have been studied extensively, but much less work has gone toward characterizing how these resources are used in conjunction to solve larger scientific challenges. To address this gap, we present our work in characterizing workloads and workflows at a data-center-wide level by examining all data transfers that occurred between storage, compute, and the external network at the National Energy Research Scientific Computing Center over a three-month period in 2019. Using a simple abstract representation of data transfers, we analyze over 100 million transfer logs from Darshan, HPSS user interfaces, and Globus to quantify the load on data paths between compute, storage, and the wide-area network based on transfer direction, user, transfer tool, source, destination, and time. We show that parallel I/O from user jobs, while undeniably important, is only one of several major I/O workloads that occurs throughout the execution of scientific workflows. We also show that this approach can be used to connect anomalous data traffic to specific users and file access patterns, and we construct time-resolved user transfer traces to demonstrate that one can systematically identify coupled data motion for individual workflows.

Lockwood, GK↗

Accelerating Simulation for High-Fidelity PV Inverter System Reliability Assessment with High-Performance Computing

The overall cost of photovoltaic (PV) systems has shown a downward trend during the last decade; however, PV inverter failures account for the highest cost of operation and maintenance. To address this, reliability tools with powerful computation and better accuracy are required for the lifetime prediction and degradation evaluation of PV inverters. This paper proposes an event-driven parallel computing-based simulator. The proposed simulator applies high-performance computing techniques and other accessory optimization techniques-including cluster merging, adaptive model updates, and steady-state identification-to make reliability assessments for PV inverters under given input mission profiles and operating conditions with high efficiency and high fidelity. The main idea of the simulator and its workflow are introduced. Then, a demo PV inverter system simulator is implemented, and the speedup of the total simulations of the switching model reaches 123.03 times.

high-performance computing↗

Integrating continuous hypermutation with high–throughput screening for optimization of cis,cis –muconic acid production in yeast

Directed evolution is a powerful method to optimize proteins and metabolic reactions towards user-defined goals. It usually involves subjecting genes or pathways to iterative rounds of mutagenesis, selection and amplification. While powerful, systematic searches through large sequence-spaces is a labour-intensive task, and can be further limited by a priori knowledge about the optimal initial search space, and/or limits in terms of screening throughput. Here, we demonstrate an integrated directed evolution workflow for metabolic pathway enzymes that continuously generate enzyme variants using the recently developed orthogonal replication system, OrthoRep and screens for optimal performance in high-throughput using a transcription factor-based biosensor. We demonstrate the strengths of this workflow by evolving a rate-limiting enzymatic reaction of the biosynthetic pathway for cis,cis-muconic acid (CCM), a precursor used for bioplastic and coatings, in Saccharomyces cerevisiae. After two weeks of simply iterating between passaging of cells to generate variant enzymes via OrthoRep and high-throughput sorting of best-performing variants using a transcription factor-based biosensor for CCM, we ultimately identified variant enzymes improving CCM titers > 13-fold compared with reference enzymes. Taken together, the combination of synthetic biology tools as adopted in this study is an efficient approach to debottleneck repetitive workflows associated with directed evolution of metabolic enzymes.

59 BASIC BIOLOGICAL SCIENCES↗

Employing sequential experiments to gain insights on the interaction between creep and fatigue damage in Ni‐base superalloys

Abstract The interaction between creep and fatigue damage in Ni‐base superalloy CMSX‐8 was explored using a sequential workflow that decouples creep and fatigue steps to quantify how accumulated creep damage interacts with subsequent isothermal low‐cycle fatigue (LCF) and vice versa. Two workflows were considered: creep followed by LCF and LCF followed by creep. For the first workflow, the subsequent LCF was evaluated at temperatures of 20°C, 750°C, and 1100°C. It was found that the extent of deleterious interaction of prior creep on LCF depended on increasing subsequent fatigue test temperature. For the LCF followed by creep, fatigue tests were first conducted at 20°C and 1100°C to 60% of life, and then creep was conducted at 800°C, where primary creep is promoted, or 900°C, where primary creep is absent. LCF damage accumulated at 1100°C accelerated creep and decreased ductility, while fatigue damage at room temperature had minimal effect on the creep behavior.

Gorgannejad, Sanam↗

Machine-learning-enabled on-the-fly analysis of RHEED patterns during thin film deposition by molecular beam epitaxy

Thin film deposition is a fundamental technology for the discovery, optimization, and manufacturing of functional materials. Deposition by molecular beam epitaxy (MBE) typically employs reflection high-energy electron diffraction (RHEED) as a real-time in situ probe of the growing film. However, the state-of-the-art for RHEED analysis during deposition requires human observation. Here, we present an approach using machine learning (ML) methods to monitor, analyze, and interpret RHEED images on-the-fly during thin film deposition. In the analysis workflow, RHEED pattern images are collected at one frame per second and featurized using a pretrained deep convolutional neural network. The feature vectors are then statistically analyzed to identify changepoints; these changepoints can be related to changes in the deposition mode from initial film nucleation to a transition regime, smooth film deposition, and in some cases, an additional transition to a rough, islanded deposition regime. The feature vectors are additionally analyzed via graph analysis and community classification. The graph is quantified as a stabilization plot, and we show that inflection points in the stabilization plot correspond to changes in the growth regime. The full RHEED analysis workflow is termed RHAAPsody and includes data transfer and output to a visual dashboard. We demonstrate the functionality of RHAAPsody by analyzing the precaptured RHEED images from epitaxial depositions of anatase TiO2 on SrTiO3(001) and show that the analysis workflow can be executed in less than 1 s. Our approach shows promise as one component of ML-enabled real-time feedback control of the MBE deposition process.

36 MATERIALS SCIENCE↗

SU-E-T-544: A Radiation Oncology-Specific Multi-Institutional Federated Database: Initial Implementation

Purpose: To implement a common database structure and user-friendly web-browser based data collection tools across several medical institutions to better support evidence-based clinical decision making and comparative effectiveness research through shared outcomes data. Methods: A consortium of four academic medical centers agreed to implement a federated database, known as Oncospace. Initial implementation has addressed issues of differences between institutions in workflow and types and breadth of structured information captured. This requires coordination of data collection from departmental oncology information systems (OIS), treatment planning systems, and hospital electronic medical records in order to include as much as possible the multi-disciplinary clinical data associated with a patients care. Results: The original database schema was well-designed and required only minor changes to meet institution-specific data requirements. Mobile browser interfaces for data entry and review for both the OIS and the Oncospace database were tailored for the workflow of individual institutions. Federation of database queries--the ultimate goal of the project--was tested using artificial patient data. The tests serve as proof-of-principle that the system as a whole--from data collection and entry to providing responses to research queries of the federated database--was viable. The resolution of inter-institutional use of patient data for research is still not completed. Conclusions: The migration from unstructured data mainly in the form of notes and documents to searchable, structured data is difficult. Making the transition requires cooperation of many groups within the department and can be greatly facilitated by using the structured data to improve clinical processes and workflow. The original database schema design is critical to providing enough flexibility for multi-institutional use to improve each institution s ability to study outcomes, determine best practices, and support research. The project has demonstrated the feasibility of deploying a federated database environment for research purposes to multiple institutions.

60 APPLIED LIFE SCIENCES↗

TH-E-BRE-08: GPU-Monte Carlo Based Fast IMRT Plan Optimization

Purpose: Intensity-modulated radiation treatment (IMRT) plan optimization needs pre-calculated beamlet dose distribution. Pencil-beam or superposition/convolution type algorithms are typically used because of high computation speed. However, inaccurate beamlet dose distributions, particularly in cases with high levels of inhomogeneity, may mislead optimization, hindering the resulting plan quality. It is desire to use Monte Carlo (MC) methods for beamlet dose calculations. Yet, the long computational time from repeated dose calculations for a number of beamlets prevents this application. It is our objective to integrate a GPU-based MC dose engine in lung IMRT optimization using a novel two-steps workflow. Methods: A GPU-based MC code gDPM is used. Each particle is tagged with an index of a beamlet where the source particle is from. Deposit dose are stored separately for beamlets based on the index. Due to limited GPU memory size, a pyramid space is allocated for each beamlet, and dose outside the space is neglected. A two-steps optimization workflow is proposed for fast MC-based optimization. At first step, rough beamlet dose calculations is conducted with only a small number of particles per beamlet. Plan optimization is followed to get an approximated fluence map. In the second step, more accurate beamlet doses are calculated, where sampled number of particles for a beamlet is proportional to the intensity determined previously. A second-round optimization is conducted, yielding the final Result. Results: For a lung case with 5317 beamlets, 10{sup 5} particles per beamlet in the first round, and 10{sup 8} particles per beam in the second round are enough to get a good plan quality. The total simulation time is 96.4 sec. Conclusion: A fast GPU-based MC dose calculation method along with a novel two-step optimization workflow are developed. The high efficiency allows the use of MC for IMRT optimizations.

60 APPLIED LIFE SCIENCES↗

SU-C-213-03: Custom 3D Printed Boluses for Radiation Therapy

Purpose: To develop a clinical workflow and to commission the process of creating custom 3d printed boluses for radiation therapy. Methods: We designed a workflow to create custom boluses using a commercial 3D printer. Contours of several patients were deformably mapped to phantoms where the test bolus contours were designed. Treatment plans were created on the phantoms following our institutional planning guideline. The DICOM file of the bolus contours were then converted to stereoLithography (stl) file for the 3d printer. The boluses were printed on a commercial 3D printer using polylactic acid (PLA) material. Custom printing parameters were optimized in order to meet the requirement of bolus composition. The workflow was tested on multiple anatomical sites such as skull, nose and chest wall. The size of boluses varies from 6×9cm2 to 12×25cm2. To commission the process, basic CT and dose properties of the printing materials were measured in photon and electron beams and compared against water and soft superflab bolus. Phantoms were then scanned to confirm the placement of custom boluses. Finally dose distributions with rescanned CTs were compared with those computer-generated boluses. Results: The relative electron density(1.08±0.006) of the printed boluses resemble those of liquid tap water(1.04±0.004). The dosimetric properties resemble those of liquid tap water(1.04±0.004). The dosimetric properties were measured at dmax with an ion chamber in electron and photon open beams. Compared with solid water and soft bolus, the output difference was within 1% for the 3D printer material. The printed boluses fit well to the phantom surfaces on CT scans. The dose distribution and DVH based on the printed boluses match well with those based on TPS generated boluses. Conclusion: 3d printing provides a cost effective and convenient solution for patient-specific boluses in radiation therapy.

60 APPLIED LIFE SCIENCES↗

TU-AB-303-03: CBCT-Based On-Site Simulation, Planning, and Delivery (OSPD) for Whole Brain Radiotherapy

Purpose: To demonstrate the feasibility of a CBCT-based on-site simulation, planning, and delivery (OSPD) for whole brain radiotherapy, in which all steps from imaging, planning to treatment delivery are performed at the treatment unit in one appointment time slot. This work serves as the proof of concept for future OSPD single fraction radiation therapy. Methods: An integrated on-site imaging, planning and delivery workflow was developed and tested for whole brain radiotherapy. An automated two-opposed-oblique-beam plan is created by utilizing the treatment planning system scripting and simple field-in-field IMRT. The IMRT plan is designed with maximum 8 control points to cover the target volume consisting of the brain to C1/C2 of the spinal cord, with dose homogeneity criteria from −5% to +7% of the prescription dose. Due to inaccuracy of reconstructed Hounsfield unit numbers in CBCT images, the dose distribution is calculated with non-heterogeneity correction introducing only clinically insignificant dose discrepancy. A coherent and synchronized workflow was designed for a team of attending physician, physicist, therapists, and dosimetrist to work closely with the ability to quickly modify, approve, and implement the treatment. Results: Thirty-one patients have been treated with this OSPD treatment, without compromising the plan quality compared to our regular clinically used parallel apposed 2D plans. The average time for these procedures are 48.02 ±11.55 minutes from the time patient entered the treatment room until s/he exited, and 35.09 ±10.35 minutes from starting CBCT until last beam delivered. This time duration is comparable to the net time when individual tasks are summed up during our regular CT- based whole brain planning and delivery. Conclusions: The OSPD whole brain treatment has been tested to be clinically feasible. The next step is to further improve the efficiency and to streamline the workflow. Other disease sites will be also tested with this new technology.

60 APPLIED LIFE SCIENCES↗

SU-F-J-110: MRI-Guided Single-Session Simulation, Online Adaptation, and Treatment

Purpose: To develop a combined simulation and treatment workflow for MRI-guided radiation therapy using the ViewRay treatment planning and delivery system. Methods: Several features of the ViewRay MRIdian planning and treatment workflows are used to simulate and treat patients that require emergent radiotherapy. A simple “pre-plan” is created on diagnostic imaging retrieved from radiology PACS, where conformal fields are created to target a volume defined by a physician based on review of the diagnostic images and chart notes. After initial consult in radiation oncology, the patient is brought to the treatment room, immobilized, and imaged in treatment position with a volumetric MR. While the patient rests on the table, the pre-plan is applied to the treatment planning MR and dose is calculated in the treatment geometry. After physician review, modification of the plan may include updating the target definition, redefining fields, or re-balancing beam weights. Once an acceptable treatment plan is finalized and approved, the patient is treated. Results: Careful preparation and judicious choices in the online planning process allow conformal treatment plans to be created and delivered in a single, thirty-minute session. Several advantages have been identified using this process as compared to conventional urgent CT simulation and delivery. Efficiency gains are notable, as physicians appreciate the predictable time commitment and patient waiting time for treatment is decreased. MR guidance in a treatment position offers both enhanced contrast for target delineation and reduction of setup uncertainties. The MRIdian system tools designed for adaptive radiotherapy are particularly useful, enabling plan changes to be made in minutes. Finally, the resulting plans, typically 6 conformal beams, are delivered as quickly as more conventional AP/PA beam arrangements with comparatively superior dose distributions. Conclusion: The ViewRay treatment planning software and delivery system can accommodate a fast simulation and treatment workflow.

60 APPLIED LIFE SCIENCES↗

SU-F-T-97: Outlier Identification in Radiation Therapy Knowledge Modeling

Purpose: To investigate the impact of outliers on knowledge modeling in radiation therapy, and develop a systematic workflow for identifying and analyzing geometric and dosimetric outliers using pelvic cases. Methods: Four groups (G1-G4) of pelvic plans were included: G1 (37 prostate cases), G2 (37 prostate plus lymph node cases), and G3 (37 prostate bed cases) are all clinical IMRT cases. G4 are 10 plans outside G1 re-planned with dynamic-arc to simulate dosimetric outliers. The workflow involves 2 steps: 1. identify geometric outliers, assess impact and clean up; 2. identify dosimetric outliers, assess impact and clean up.1. A baseline model was trained with all G1 cases. G2/G3 cases were then individually added to the baseline model as geometric outliers. The impact on the model was assessed by comparing leverage statistic of inliers (G1) and outliers (G2/G3). Receiver-operating-characteristics (ROC) analysis was performed to determine optimal threshold. 2. A separate baseline model was trained with 32 G1 cases. Each G4 case (dosimetric outliers) was then progressively added to perturb this model. DVH predictions were performed using these perturbed models for remaining 5 G1 cases. Normal tissue complication probability (NTCP) calculated from predicted DVH were used to evaluate dosimetric outliers’ impact. Results: The leverage of inliers and outliers was significantly different. The Area-Under-Curve (AUC) for differentiating G2 from G1 was 0.94 (threshold: 0.22) for bladder; and 0.80 (threshold: 0.10) for rectum. For differentiating G3 from G1, the AUC (threshold) was 0.68 (0.09) for bladder, 0.76 (0.08) for rectum. Significant increase in NTCP started from models with 4 dosimetric outliers for bladder (p<0.05), and with only 1 dosimetric outlier for rectum (p<0.05). Conclusion: We established a systematic workflow for identifying and analyzing geometric and dosimetric outliers, and investigated statistical metrics for detecting. Results validated the necessity for outlier detection and clean-up to enhance model quality in clinical practice. Research Grant: Varian master research grant.

60 APPLIED LIFE SCIENCES↗

SU-F-T-433: Evaluation of a New Dose Mimicking Application for Clinical Flexibility and Reliability

Purpose: Clinical workflow and machine down time occasionally require patients to be temporarily treated on a system other than the initial treatment machine. A new commercial dose mimicking application provides automated cross-platform treatment planning to expedite this clinical flexibility. The aim of this work is to evaluate the feasibility of automatic plan creation and establish a robust clinical workflow for prostate and pelvis patients. Methods: Five prostate and five pelvis patients treated with helical plans were selected for re-planning with the dose mimicking application, covering both simple and complex scenarios. Two-arc VMAT and 7- and 9-field IMRT plans were generated for each case, with the objective function of achieving similar dose volume histogram from the initial helical plans. Dosimetric comparisons include target volumes and organs at risk (OARs) (rectum, bladder, small bowel, femoral heads, etc.). Dose mimicked plans were evaluated by a radiation oncologist, and patient-specific QAs were performed to validate delivery. Results: Overall plan generation and transfer required around 30 minutes of dosimetrist’s time once the dose-mimicking protocol is setup for each site. The resulting VMAT and 7- and 9-field IMRT plans achieved equivalent PTV coverage and homogeneity (D99/DRx = 97.3%, 97.2%, 97.2% and HI = 6.0, 5.8, and 5.9, respectively), compared to helical plans (97.6% and 4.6). The OAR dose discrepancies were up to 6% in rectum Dmean, but generally lower in bladder, femoral heads, bowel and penile bulb. In the context of 1–5 fractions, the radiation oncologist evaluated the dosimetric changes as not clinically significant. All delivery QAs achieved >90% pass with a 3%/3mm gamma criteria. Conclusion: The automated dose-mimicking workflow offers a strategy to avoid missing treatment fractions due to machine down time with non-clinically significant changes in dosimetry. Future work will further optimize dose mimicking plans and investigate other cross-platform treatment delivery options.

60 APPLIED LIFE SCIENCES↗

SU-G-TeP1-05: Development and Clinical Introduction of Automated Radiotherapy Treatment Planning for Prostate Cancer

Purpose: To develop an automated radiotherapy treatment planning and optimization workflow for prostate cancer in order to generate clinical treatment plans. Methods: A fully automated radiotherapy treatment planning and optimization workflow was developed based on the treatment planning system Monaco (Elekta AB, Stockholm, Sweden). To evaluate our method, a retrospective planning study (n=100) was performed on patients treated for prostate cancer with 5 field intensity modulated radiotherapy, receiving a dose of 35×2Gy to the prostate and vesicles and a simultaneous integrated boost of 35×0.2Gy to the prostate only. A comparison was made between the dosimetric values of the automatically and manually generated plans. Operator time to generate a plan and plan efficiency was measured. Results: A comparison of the dosimetric values show that automatically generated plans yield more beneficial dosimetric values. In automatic plans reductions of 43% in the V72Gy of the rectum and 13% in the V72Gy of the bladder are observed when compared to the manually generated plans. Smaller variance in dosimetric values is seen, i.e. the intra- and interplanner variability is decreased. For 97% of the automatically generated plans and 86% of the clinical plans all criteria for target coverage and organs at risk constraints are met. The amount of plan segments and monitor units is reduced by 13% and 9% respectively. Automated planning requires less than one minute of operator time compared to over an hour for manual planning. Conclusion: The automatically generated plans are highly suitable for clinical use. The plans have less variance and a large gain in time efficiency has been achieved. Currently, a pilot study is performed, comparing the preference of the clinician and clinical physicist for the automatic versus manual plan. Future work will include expanding our automated treatment planning method to other tumor sites and develop other automated radiotherapy workflows.

60 APPLIED LIFE SCIENCES↗

MO-B-BRC-03: CT-Based Prostate HDR

Brachytherapy has proven to be an effective treatment option for prostate cancer. Initially, prostate brachytherapy was delivered through permanently implanted low dose rate (LDR) radioactive sources; however, high dose rate (HDR) temporary brachytherapy for prostate cancer is gaining popularity. Needle insertion during prostate brachytherapy is most commonly performed under ultrasound (U/S) guidance; however, treatment planning may be performed utilizing several imaging modalities either in an intra- or post-operative setting. During intra-operative prostate HDR, the needles are imaged during implantation, and planning may be performed in real time. At present, the most common imaging modality utilized for intra-operative prostate HDR is U/S. Alternatively, in the post-operative setting, following needle implantation, patients may be simulated with computed tomography (CT) or magnetic resonance imaging (MRI). Each imaging modality and workflow provides its share of benefits and limitations. Prostate HDR has been adopted in a number of cancer centers across the nation. In this educational session, we will explore the role of U/S, CT, and MRI in HDR prostate brachytherapy. Example workflows and operational details will be shared, and we will discuss how to establish a prostate HDR program in a clinical setting. Learning Objectives: Review prostate HDR techniques based on the imaging modality Discuss the challenges and pitfalls introduced by the three imagebased options for prostate HDR brachytherapy Review the QA process and learn about the development of clinical workflows for these imaging options at different institutions.

60 APPLIED LIFE SCIENCES↗

MO-B-BRC-04: MRI-Based Prostate HDR

Brachytherapy has proven to be an effective treatment option for prostate cancer. Initially, prostate brachytherapy was delivered through permanently implanted low dose rate (LDR) radioactive sources; however, high dose rate (HDR) temporary brachytherapy for prostate cancer is gaining popularity. Needle insertion during prostate brachytherapy is most commonly performed under ultrasound (U/S) guidance; however, treatment planning may be performed utilizing several imaging modalities either in an intra- or post-operative setting. During intra-operative prostate HDR, the needles are imaged during implantation, and planning may be performed in real time. At present, the most common imaging modality utilized for intra-operative prostate HDR is U/S. Alternatively, in the post-operative setting, following needle implantation, patients may be simulated with computed tomography (CT) or magnetic resonance imaging (MRI). Each imaging modality and workflow provides its share of benefits and limitations. Prostate HDR has been adopted in a number of cancer centers across the nation. In this educational session, we will explore the role of U/S, CT, and MRI in HDR prostate brachytherapy. Example workflows and operational details will be shared, and we will discuss how to establish a prostate HDR program in a clinical setting. Learning Objectives: Review prostate HDR techniques based on the imaging modality Discuss the challenges and pitfalls introduced by the three imagebased options for prostate HDR brachytherapy Review the QA process and learn about the development of clinical workflows for these imaging options at different institutions.

60 APPLIED LIFE SCIENCES↗