Search NASA⌕ Search

SEARCH · Search NASA

Results for “additional protocol”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,189 records · Page 66

SU-C-207-02: A Method to Estimate the Average Planar Dose From a C-Arm CBCT Acquisition

Purpose: The planar average dose in a C-arm Cone Beam CT (CBCT) acquisition had been estimated in the past by averaging the four peripheral dose measurements in a CTDI phantom and then using the standard 2/3rds peripheral and 1/3 central CTDIw method (hereafter referred to as Dw). The accuracy of this assumption has not been investigated and the purpose of this work is to test the presumed relationship. Methods: Dose measurements were made in the central plane of two consecutively placed 16cm CTDI phantoms using a 0.6cc ionization chamber at each of the 4 peripheral dose bores and in the central dose bore for a C-arm CBCT protocol. The same setup was scanned with a circular cut-out of radiosensitive gafchromic film positioned between the two phantoms to capture the planar dose distribution. Calibration curves for color pixel value after scanning were generated from film strips irradiated at different known dose levels. The planar average dose for red and green pixel values was calculated by summing the dose values in the irradiated circular film cut out. Dw was calculated using the ionization chamber measurements and film dose values at the location of each of the dose bores. Results: The planar average dose using both the red and green pixel color calibration curves were within 10% agreement of the planar average dose estimated using the Dw method of film dose values at the bore locations. Additionally, an average of the planar average doses calculated using the red and green calibration curves differed from the ionization chamber Dw estimate by only 5%. Conclusion: The method of calculating the planar average dose at the central plane of a C-arm CBCT non-360 rotation by calculating Dw from peripheral and central dose bore measurements is a reasonable approach to estimating the planar average dose. Research Grant, Siemens AG.

60 APPLIED LIFE SCIENCES↗

SPRUCE Vegetation Phenology in Experimental Plots from Phenocam Imagery, 2015-2022

This data set consists of PhenoCam data from the SPRUCE experiment from the beginning of whole ecosystem warming (Hanson et al. 2017) in August 2015 through March 31 of 2023, with start- and end-of-season phenological transition dates derived through the end of autumn 2022. Digital cameras, or phenocams, installed in each SPRUCE enclosure track seasonal variation in vegetation “greenness”, a proxy for vegetation phenology and associated physiological activity. Three separate regions of interest (ROIs) were defined for each camera field of view, corresponding to different vegetation types and demarcating (1) Picea trees (vegetation type EN, for evergreen needleleaf); (2) Larix trees (vegetation type DN, for deciduous needleleaf); and (3) the mixed shrub layer (vegetation type SH). This data set consists of three sets of data files: 3-day summary product files: One file for each camera and each ROI (i.e. vegetation type), characterizing vegetation color at a 3-day time step Contains 35 files in *.csv format inside a compressed (*.zip) file. Transition date file: Estimates “greenness rising” (spring) and “greenness falling” (autumn) transition dates derived from the smoothed daily green chromatic coordinate (GCC) values, for each camera and each ROI (i.e. vegetation type) Contains one file in *.csv format Snow flag files: Indicate days with snow on trees or snow on ground for each experimental enclosure Contains two files in *.csv format, one for snow on trees and one for snow on ground This data set consists of two sets of companion files: Accompanying HTML files show the 90th quantiles of the mean GCC plotted together with transition dates for each vegetation type and plot. Contains three files in HTML format, one for each vegetation type One additional file in HTML format with the transition dates plotted for each vegetation type, by year R files for processing Phenocam files and flags. Contains five files in R file (*.R) format in one compressed (*.zip) file User Note: All imagery is posted in near-real time to the PhenoCam Project web page (http://phenocam.sr.unh.edu/), where it is publicly available. Scroll to “spruce” in the Gallery or link directly to the 29 SPRUCE cameras at https://tinyurl.com/y7z5mau7. The data reported here are based on the complete camera record from SPRUCE and supersedes the previously released phenocam datasets (see Related Data Sets). The estimated transition dates for previously released datasets may differ slightly (in most cases, by ±3 days or less), because following standard PhenoCam processing protocols (Richardson et al. 2018, Scientific Data), smoothing and interpolation, outlier removal, and transition date estimation are always conducted using the full data record.

SPRUCE Experiment, Marcell Experimental Forest, Sp↗

Multi‐Material Gradient Printing Using Meniscus‐enabled Projection Stereolithography (MAPS)

Light‐based additive manufacturing methods are widely used to print high‐resolution 3D structures for applications in tissue engineering, soft robotics, photonics, and microfluidics, among others. Despite this progress, multi‐material printing with these methods remains challenging due to constraints associated with hardware modifications, control systems, cross‐contamination, waste, and resin properties. Here, a new printing platform coined Meniscus‐enabled Projection Stereolithography (MAPS) is reported, a vat‐free method that relies on generating and maintaining a resin meniscus between a crosslinked structure and bottom window to print lateral, vertical, discrete, or gradient multi‐material 3D structures with no waste and user‐defined mixing between layers. MAPS is compatible with a wide range of resins shown and can print complex multi‐material 3D structures without requiring specialized hardware, software, or complex washing protocols. MAPS's ability to print structures with microscale variations in mechanical stiffness, opacity, surface energy, cell densities, and magnetic properties provides a generic method to make advanced materials for a broad range of applications.

bioprinting↗

Metal leaching from Lithium-ion and Nickel-metal hydride batteries and photovoltaic modules in simulated landfill leachates and municipal solid waste materials

Photovoltaic (PV) modules and batteries can either be recycled or disposed of in landfills at end-of-life (EoL). This work focuses on disposal since the benefit of recycling PV modules and batteries is well established. This study characterizes the potential toxicity due to metals leaching from selected PV modules and batteries through both the Toxicity Characteristic Leaching Procedure (TCLP) and in-house batch leaching protocols to probe the impact on metallic ion mobility as a function of the different types of e-waste entering the waste stream, the magnitude of device damage when placed into the waste stream, and the simulated municipal solid waste (SMSW) composition. Our results showed that one PV module and three battery types in this study should be classified as hazardous waste within the U.S. However, for some of the other e-wastes, metals of concern including Cr, Cu, Hg, Ni, Pb, and Zn leached during the batch tests but not in the TCLP regulatory method. For most of the waste types, the amounts of metals that leached in the TCLP test and batch tests were much lower than the total extractable amounts, demonstrating the potential for additional unaccounted for amounts of metals to leach. Our results demonstrate that the TCLP regulatory method might fail at predicting potential leaching and at capturing the complexity of e-waste leaching in landfill conditions. It confirms that additional work is needed urgently to develop appropriate EoL procedures for MSW with PV and battery e-waste.

42 ENGINEERING↗

Response of LiF:Mg,Ti thermoluminescent dosimeters at photon energies relevant to the dosimetry of brachytherapy (<1 MeV)

Purpose: High energy photon beams are used in calibrating dosimeters for use in brachytherapy since absorbed dose to water can be determined accurately and with traceability to primary standards in such beams, using calibrated ion chambers and standard dosimetry protocols. For use in brachytherapy, beam quality correction factors are needed, which include corrections for differences in mass energy absorption properties between water and detector as well as variations in detector response (intrinsic efficiency) with radiation quality, caused by variations in the density of ionization (linear energy transfer (LET) -distributions) along the secondary electron tracks. The aim of this work was to investigate experimentally the detector response of LiF:Mg,Ti thermoluminescent dosimeters (TLD) for photon energies below 1 MeV relative to {sup 60}Co and to address discrepancies between the results found in recent publications of detector response. Methods: LiF:Mg,Ti dosimeters of formulation MTS-N Poland were irradiated to known values of air kerma free-in-air in x-ray beams at tube voltages 25-250 kV, in {sup 137}Cs- and {sup 60}Co-beams at the Swedish Secondary Standards Dosimetry Laboratory. Conversions from air kerma free-in-air into values of mean absorbed dose in the dosimeters in the actual irradiation geometries were made using EGSnrc Monte Carlo simulations. X-ray energy spectra were measured or calculated for the actual beams. Detector response relative to that for {sup 60}Co was determined at each beam quality. Results: An increase in relative response was seen for all beam qualities ranging from 8% at tube voltage 25 kV (effective energy 13 keV) to 3%-4% at 250 kV (122 keV effective energy) and {sup 137}Cs with a minimum at 80 keV effective energy (tube voltage 180 kV). The variation with effective energy was similar to that reported by Davis et al.[Radiat. Prot. Dosim. 106, 33-43 (2003)] with our values being systematically lower by 2%-4%. Compared to the results by Nunn et al.[Med. Phys. 35, 1861-1869 (2008)], the relative detector response as a function of effective energy differed in both shape and magnitude. This could be explained by the higher maximum read-out temperature (350 deg. C) used by Nunn et al.[Med. Phys. 35, 1861-1869 (2008)], allowing light emitted from high-temperature peaks with a strong LET dependence to be registered. Use of TLD-100 by Davis et al.[Radiat. Prot. Dosim. 106, 33-43 (2003)] with a stronger super-linear dose response compared to MTS-N was identified as causing the lower relative detector response in this work. Conclusions: Both careful dosimetry and strict protocols for handling the TLDs are required to reach solid experimental data on relative detector response. This work confirms older findings that an over-response relative to {sup 60}Co exists for photon energies below 200-300 keV. Comparison with the results from the literature indicates that using similar protocols for annealing and read-out, dosimeters of different makes (TLD-100, MTS-N) differ in relative detector response. Though universality of the results has not been proven and further investigation is needed, it is anticipated that with the use of strict protocols for annealing and read-out, it will be possible to determine correction factors that can be used to reduce uncertainties in dose measurements around brachytherapy sources at photon energies where primary standards for absorbed dose to water are not available.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Diazotroph Community Characterization via a High-Throughput nifH Amplicon Sequencing and Analysis Pipeline

The dinitrogenase reductase gene ( nifH ) is the most widely established molecular marker for the study of nitrogen-fixing prokaryotes in nature. A large number of PCR primer sets have been developed for nifH amplification, and the effective deployment of these approaches should be guided by a rapid, easy-to-use analysis protocol. Bioinformatic analysis of marker gene sequences also requires considerable expertise. In this study, we advance the state of the art for nifH analysis by evaluating nifH primer set performance, developing an improved amplicon sequencing workflow, and implementing a user-friendly bioinformatics pipeline. Furthermore, the developed amplicon sequencing workflow is a three-stage PCR-based approach that uses established technologies for incorporating sample-specific barcode sequences and sequencing adapters. Based on our primer evaluation, we recommend the Ando primer set be used with a modified annealing temperature of 58°C, as this approach captured the largest diversity of nifH templates, including paralog cluster IV/V sequences. To improve nifH sequence analysis, we developed a computational pipeline which infers taxonomy and optionally filters out paralog sequences. In addition, we employed an empirical model to derive optimal operational taxonomic unit (OTU) cutoffs for the nifH gene at the species, genus, and family levels. A comprehensive workflow script named TaxADivA (TAXonomy Assignment and DIVersity Assessment) is provided to ease processing and analysis of nifH amplicons. Our approach is then validated through characterization of diazotroph communities across environmental gradients in beach sands impacted by the Deepwater Horizon oil spill in the Gulf of Mexico, in a peat moss-dominated wetland, and in various plant compartments of a sugarcane field. IMPORTANCE: Nitrogen availability often limits ecosystem productivity, and nitrogen fixation, exclusive to prokaryotes, comprises a major source of nitrogen input that sustains food webs. The nifH gene, which codes for the iron protein of the nitrogenase enzyme, is the most widely established molecular marker for the study of nitrogen-fixing microorganisms (diazotrophs) in nature. In this study, a flexible sequencing/analysis pipeline, named TaxADivA, was developed for nifH amplicons produced by Illumina paired-end sequencing, and it enables an inference of taxonomy, performs clustering, and produces output in formats that may be used by programs that facilitate data exploration and analysis. Diazotroph diversity and community composition are linked to ecosystem functioning, and our results advance the phylogenetic characterization of diazotroph communities by providing empirically derived nifH similarity cutoffs for species, genus, and family levels. Thus, the utility of our pipeline is validated for diazotroph communities in a variety of ecosystems, including contaminated beach sands, peatland ecosystems, living plant tissues, and rhizosphere soil.

59 BASIC BIOLOGICAL SCIENCES↗

The development and application of the Remotely Monitored Sealing Array (RMSA).

Advanced sealing technologies are often an integral part of a containment surveillance (CS) approach to detect undeclared diversion of nuclear materials. As adversarial capabilities continue to advance, the sophistication of the seal design must advance as well. The intelligent integration of security concepts into a physical technology used to seal monitored items is a fundamental requirement for secure containment. Seals have a broad range of capabilities. These capabilities must be matched appropriately to the application to establish the greatest effectiveness from the seal. However, many current seal designs and their application fail to provide the high confidence of detection and timely notification that can be appreciated with new technology. Additionally, as monitoring needs rapidly expand, out-pacing budgets, remote monitoring of low-cost autonomous sealing technologies becomes increasingly appealing. The Remotely Monitored Sealing Array (RMSA) utilizes this technology and has implemented cost effective security concepts establishing the high confidence that is expected of active sealing technology today. RMSA is a system of relatively low-cost but secure active loop seals for the monitoring of nuclear material containers. The sealing mechanism is a fiber optic loop that is pulsed using a low-power LED circuit with a coded signal to verify integrity. Battery life is conserved by the use of sophisticated power management techniques, permitting many years of reliable operation without battery replacement or other maintenance. Individual seals communicate by radio using a secure transmission protocol using either of two specially designated communication frequency bands. Signals are encrypted and authenticated by private key, established during the installation procedure, and the seal bodies feature both active and passive tamper indication. Seals broadcast to a central 'translator' from which information is both stored locally and/or transmitted remotely for review. The system is especially appropriate for nuclear material storage facilities, indoor or outdoor, enabling remote inspection of status rather than tedious individual seal verification, and without the need for interconnected cabling. A handheld seal verifier is also available for an inspector to verify any particular individual seal in close proximity. This paper will discuss the development of the RMSA sealing system, its capabilities, its application philosophy, and projected future trends.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Disease Control After Reduced Volume Conformal and Intensity Modulated Radiation Therapy for Childhood Craniopharyngioma

Purpose: To estimate the rate of disease control after conformal radiation therapy using reduced clinical target volume (CTV) margins and to determine factors that predict for tumor progression. Methods and Materials: Eighty-eight children (median age, 8.5 years; range, 3.2-17.6 years) received conformal or intensity modulated radiation therapy between 1998 and 2009. The study group included those prospectively treated from 1998 to 2003, using a 10-mm CTV, defined as the margin surrounding the solid and cystic tumor targeted to receive the prescription dose of 54 Gy. The CTV margin was subsequently reduced after 2003, yielding 2 groups of patients: those treated with a CTV margin greater than 5 mm (n=26) and those treated with a CTV margin less than or equal to 5 mm (n=62). Disease progression was estimated on the basis of additional variables including sex, race, extent of resection, tumor interventions, target volume margins, and frequency of weekly surveillance magnetic resonance (MR) imaging during radiation therapy. Median follow-up was 5 years. Results: There was no difference between progression-free survival rates based on CTV margins (>5 mm vs ≤5 mm) at 5 years (88.1% ± 6.3% vs 96.2% ± 4.4% [P=.6386]). There were no differences based on planning target volume (PTV) margins (or combined CTV plus PTV margins). The PTV was systematically reduced from 5 to 3 mm during the time period of the study. Factors predictive of superior progression-free survival included Caucasian race (P=.0175), no requirement for cerebrospinal fluid shunting (P=.0066), and number of surveillance imaging studies during treatment (P=.0216). Patients whose treatment protocol included a higher number of weekly surveillance MR imaging evaluations had a lower rate of tumor progression. Conclusions: These results suggest that targeted volume reductions for radiation therapy using smaller margins are feasible and safe but require careful monitoring. We are currently investigating the differences in outcome based on host factors to explain the results.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-F-T-231: Improving the Efficiency of a Radiotherapy Peer-Review System for Quality Assurance

Purpose: To improve the efficiency of a radiotherapy peer-review system using a commercially available software application for plan quality evaluation and documentation. Methods: A commercial application, FullAccess (Radialogica LLC, Version 1.4.4), was implemented in a Citrix platform for peer-review process and patient documentation. This application can display images, isodose lines, and dose-volume histograms and create plan reports for peer-review process. Dose metrics in the report can also be benchmarked for plan quality evaluation. Site-specific templates were generated based on departmental treatment planning policies and procedures for each disease site, which generally follow RTOG protocols as well as published prospective clinical trial data, including both conventional fractionation and hypo-fractionation schema. Once a plan is ready for review, the planner exports the plan to FullAccess, applies the site-specific template, and presents the report for plan review. The plan is still reviewed in the treatment planning system, as that is the legal record. Upon physician’s approval of a plan, the plan is packaged for peer review with the plan report and dose metrics are saved to the database. Results: The reports show dose metrics of PTVs and critical organs for the plans and also indicate whether or not the metrics are within tolerance. Graphical results with green, yellow, and red lights are displayed of whether planning objectives have been met. In addition, benchmarking statistics are collected to see where the current plan falls compared to all historical plans on each metric. All physicians in peer review can easily verify constraints by these reports. Conclusion: We have demonstrated the improvement in a radiotherapy peer-review system, which allows physicians to easily verify planning constraints for different disease sites and fractionation schema, allows for standardization in the clinic to ensure that departmental policies are maintained, and builds a comprehensive database for potential clinical outcome evaluation.

60 APPLIED LIFE SCIENCES↗

Microreactor Automated Control System - Digital Twin Models and Advanced Control Systems Updates

Automation of control systems is expected to be important in the economic and safe operation of microreactors. Therefore, there is a need to develop and demonstrate automated control for microreactors, along with the development of testbeds for this purpose. This report provides updates on the status of a nonnuclear microreactor automated control system (MACS)—a real-time, hardware-in-the-loop testbed for non-nuclear testing of microreactor control system automation. A real-time hardware-in-the-loop testbed incorporates the realistic dynamics of physical systems into control system development and testing. The collaborative effort between Oak Ridge National Laboratory (ORNL) and Idaho National Laboratory (INL) resulted in the development of a prototypic microreactor plant-level digital twin that includes the reactor and a balance of plant system. Advanced control strategies were incorporated to demonstrate testing of control automation solutions. The gRPC communication protocol, which was implemented in the hardware-in-the-loop testbed by INL, was coupled to a digital twin model developed using the TRANsient Simulation Framework of Reconfigurable Models (TRANSFORM) library in Modelica. This digital twin simulation was tested with the ViBRANT hardware for realistic feedback and visual representation of control action in real time. A modular Python client structure was developed to manage functional mock-up unit-based simulation and real-time gRPC communication. Hardware-in-the-loop testing indicated that the modeled reactor—a natural-convection, molten-salt coolant loop configuration—responds well to control of drum positioning for modulation of reactor core power, as well as system-level control and downstream demand changes. Ongoing research is focused on integrating additional control algorithms that utilize data from newly included sensors within the MACS hardware testbed, as well as demonstrating and assessing the performance of the different automated control algorithms on multiple additional operational scenarios.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Genetic time traveling: sequencing old herbarium specimens, including the oldest herbarium specimen sequenced from kingdom Fungi, reveals the population structure of an agriculturally significant rust

Summary Sequencing herbarium specimens can be instrumental in answering ecological, evolutionary, and taxonomic inquiries. We developed a protocol for sequencing herbarium specimens of rust fungi (Pucciniales) and proceeded to sequence specimens ranging from 4 to 211 yr old from five different genera. We then obtained sequences from an economically important biological control agent, Puccinia suaveolens , to highlight the potential of sequencing herbarium specimens in an ecological sense and to evaluate the following hypotheses: (1) The population structure of a plant pathogen changes over time, and (2) introduced pathogens are more diverse in their native range. Our efforts resulted in sequences from 87 herbarium specimens that revealed a high level of diversity with a population structure that exhibited spatial–temporal patterns. The specimens sequenced from Europe showed more diversity than the ones from North America, uncovering an invasion pattern likely related to its European native host in North America. Additionally, to the best of our knowledge, the specimen from France collected in c. 1811 is the oldest herbarium specimen sequenced from kingdom Fungi. In conclusion, sequencing old herbarium specimens is an important tool that can be extrapolated to better understand plant–microbe evolution and to evaluate old type specimens to solidify the taxonomy of plant pathogenic fungi.

Plant Sciences↗

Costs to Automate Demand Response - Taxonomy and Results from Field Studies and Programs

During the past decade, the technology to automate demand response (DR) in buildings and industrial facilities has advanced significantly. Automation allows rapid, repeatable, reliable operation. This study focuses on costs for DR automation in commercial buildings with some discussion on residential buildings and industrial facilities. DR automation technology relies on numerous components, including communication systems, hardware and software gateways, standards-based messaging protocols, controls and integration platforms, and measurement and telemetry systems. This report compares cost data from several DR automation programs and pilot projects, evaluates trends in the cost per unit of DR and kilowatts (kW) available from automated systems, and applies a standard naming convention and classification or taxonomy for system elements. Median costs for the 56 installed automated DR systems studied here are about $200/kW. The deviation around this median is large with costs in some cases being an order of magnitude great or less than the median. This wide range is a result of variations in system age, size of load reduction, sophistication, and type of equipment included in cost analysis. The costs to automate fast DR systems for ancillary services are not fully analyzed in this report because additional research is needed to determine the total cost to install, operate, and maintain these systems. However, recent research suggests that they could be developed at costs similar to those of existing hot-summer DR automation systems. This report considers installation and configuration costs and does include the costs of owning and operating DR automation systems. Future analysis of the latter costs should include the costs to the building or facility manager costs as well as utility or third party program manager cost.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Performance of Windows in Walls With Continuous Insulation

Window openings in walls are a significant contributor to poor thermal performance because of thermal bridging through the framing members (e.g., studs, joists, plates, bracing) and because windows lack the thermal properties of insulation. Window installation guidance for walls with continuous insulation (CI) is critical for continued market growth of this energy efficiency technology. This research project offers window manufacturers a starting point and a potential path toward developing installation instructions for windows over CI. The objectives of the research include evaluating the common method for installing windows in walls with CI, as well as establishing acceptance criteria for evaluating the performance of windows installed in walls with and without CI. The research measures: 1. The performance characteristics (e.g., water management, structural integrity) of windows in walls without CI. 2. The performance of different thicknesses and types of CI used in walls. 3. The performance of different types of window assemblies (e.g., double-hung windows, mulled double-hung windows, mulled casement windows, and slider windows) installed over CI. 4. The performance of window flange types (e.g., rigid mounting and less robust flanges) installed over CI. 5. Installing windows over CI using baseline installation instructions versus window manufacturer installation instructions. The project’s sequential testing protocol consists of the following: • A water penetration resistance testing adapted from two ASTM standards: E331 (uniform static air pressure in four steps) and E547 (cyclic static air pressure) • A temperature cycling adapted from ASTM E2264 Method B (convective hot air) • A service condition wind loading test adapted from ASTM E330 • A six-month vertical displacement observation phase prior to the structural performance testing • A final water penetration resistance test after vertical displacement observation • A structural performance test adapted from ASTM E330. Key research findings include: • The criterion for passing a water penetration resistance test is that there is no water overflowing at the interior face of the studs. If there is any bubbling or slight pooling of water at the sill, then it must recede after the pressure is removed. Excessive leakage and/or water leaking to the interior face of the framing around the window constitutes a failure. • All single double-hung windows installed directly to lumber or over oriented strand board passed all test protocols. • For most wall specimens, the test results showed that the use of foam sheathing did not affect the performance of the window for water leakage. • All wall specimens underwent temperature cycling. The results indicated that temperature cycling had little to no effect on windows installed over foam sheathing. • For wall specimens that underwent six-month vertical displacement monitoring, the results showed that windows installed over foam sheathing do not sag over time. • The single-hung and double-hung windows installed using window manufacturer installation instructions passed the structural performance test, compared to failures observed in windows that were installed using generic installation instructions. The generic and manufacturer installation methods differed on the following construction details: type of fasteners, fastening patterns on the flanges, and window shimming details. • Additional testing is required to determine methods to improve structural pressure performance of slider windows. Potential solutions that would require additional testing may include fastener spacing, different types of fasteners, masonry window clips, construction adhesive, foam sealant, stronger window flange material, and/or straps.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Merged Observatory Data Files (MODFs): an integrated observational data product supporting process-oriented investigations and diagnostics

A large and ever-growing body of geophysical information is measured in campaigns and at specialized observatories as a part of scientific expeditions and experiments. These collections of observed data include many essential climate variables (as defined by the Global Climate Observing System) but are often distinguished by a wide range of additional non-routine measurements that are designed to not only document the state of the environment but also the drivers that contribute to that state. These field data are used not only to further understand environmental processes through observation-based studies but also to provide baseline data to test model performance and to codify understanding to improve predictive capabilities. To address the considerable barriers and difficulty in utilizing these diverse and complex data for observation–model research, the Merged Observatory Data File (MODF) concept has been developed. A MODF combines measurements from multiple instruments into a single file that complies with well-established data format and metadata practices and has been designed to parallel the development of corresponding Merged Model Data Files (MMDFs). Using the MODF and MMDF protocols will facilitate the evolution of model intercomparison projects into model intercomparison and improvement projects by putting observation and model data “on the same page” in a timely manner. The MODF concept was developed especially for weather forecast model studies in the Arctic. The surprisingly complex process of implementing MODFs in that context refined the concept itself. Thus, this article explains the concept of MODFs by providing details on the issues that were revealed and resolved during that first specific implementation. Detailed instructions are provided on how to make MODFs, and this article can be considered a MODF creation manual.

54 ENVIRONMENTAL SCIENCES↗

Delamination-Assisted Ultrafast Wrinkle Formation in a Freestanding Film

Freestanding films provide a versatile platform for materials engineering thanks to additional structural motifs not found in films with a substrate. A ubiquitous example is wrinkles, yet little is known about how they can develop over as fast as a few picoseconds due to a lack of experimental probes to visualize their dynamics in real time on the nanoscopic scale. Here, we use time-resolved electron diffraction to directly observe light-activated wrinkling formation in freestanding La 2/3 Ca 1/3 MnO 3 films. Via a “lock-in” analysis of oscillations in the diffraction peak position, intensity, and width, we quantitatively reconstructed how wrinkles develop on the time scale of lattice vibration. Contrary to the common assumption of fixed boundary conditions, we found that wrinkle development is associated with ultrafast delamination at the film boundaries. Finally, our work provides a generic protocol to quantify wrinkling dynamics in freestanding films and highlights the importance of the film–substrate interaction in determining the properties of freestanding structures.

36 MATERIALS SCIENCE↗

Save Energy Now Assessments Results 2008 Summary Report

In October 2005, U.S. Department of Energy Secretary Bodman launched his Easy Ways to Save Energy campaign with a promise to provide energy assessments to 200 of the largest U.S. manufacturing plants. DOE's Industrial Technologies Program (ITP) responded to the Secretary's campaign with its Save Energy Now initiative, featuring a new and highly cost-effective form of energy savings assessment. The approach for these assessments drew heavily on the existing resources of ITP's technology delivery component. Over the years, ITP Technology Delivery has worked with industry partners to assemble a suite of respected software tools, proven assessment protocols, training curricula, certified energy experts, and strong partnerships for deployment. The Save Energy Now assessments conducted in calendar year 2006 focused on natural gas savings and targeted many of the nation's largest manufacturing plants - those that consume at least 1 TBtu of energy annually. The 2006 Save Energy Now assessments focused primarily on assessments of steam and process heating systems, which account for an estimated 74% of all natural gas use by U.S. manufacturing plants. Because of the success of the Save Energy Now assessments conducted in 2006 and 2007, the program was expanded and enhanced in two major ways in 2008: (1) a new goal was set to perform at least 260 assessments; and (2) the assessment focus was expanded to include pumping, compressed air, and fan systems in addition to steam and process heating. DOE ITP also has developed software tools to assess energy efficiency improvement opportunities in pumping, compressed air, and fan systems. The Save Energy Now assessments integrate a strong training component designed to teach industrial plant personnel how to use DOE's opportunity assessment software tools. This approach has the advantages of promoting strong buy-in of plant personnel for the assessment and its outcomes and preparing them better to independently replicate the assessment process at the company's other facilities. Another important element of the Save Energy Now assessment process is the follow-up process used to identify how many of the recommended savings opportunities from individual assessments have been implemented in the industrial plants. Plant personnel involved with the Save Energy Now assessments are contacted 6 months, 12 months, and 24 months after individual assessments are completed to determine implementation results. A total of 260 Save Energy Now assessments were successfully completed in calendar year 2008. This means that a total of 718 assessments were completed in 2006, 2007, and 2008. As of July 2009, we have received a total of 239 summary reports from the ESAs that were conducted in year 2008. Hence, at the time that this report was prepared, 680 final assessment reports were completed (200 from year 2006, 241 from year 2007, and 239 from year 2008). The total identified potential cost savings from these 680 assessments is $1.1 billion per year, including natural gas savings of about 98 TBtu per year. These results, if fully implemented, could reduce CO{sub 2} emissions by about 8.9 million metric tons annually. When this report was prepared, data on implementation of recommended energy and cost savings measures from 488 Save Energy Now assessments were available. For these 488 plants, measures saving a total of $147 million per year have been implemented, measures that will save $169 million per year are in the process of being implemented, and plants are planning implementation of measures that will save another $239 million per year. The implemented recommendations are already achieving total CO{sub 2} reductions of about 1.8 million metric tons per year. This report provides a summary of the key results for the Save Energy Now assessments completed in 2008; details of the 6-month, 12-month, and 24-month implementation results obtained to date; and an evaluation of these implementation results. This report also summarizes key accomplishments, findings, and lessons learned from all the Save Energy Now assessments completed to date. A separate report (Wright et al. 2010) provides more detailed information on key results for all of the 2008 assessments of steam, process heating, pumping, compressed air, and fan systems. Two prior reports (Wright et al. 2007 and Wright et al. 2009) detail the results from the 2006 and 2007 assessments and discuss the major components of the assessment process and improvements in the process made in 2007.

03 NATURAL GAS↗

Save Energy Now Assessments Results 2008 Detailed Report

In October 2005, U.S. Department of Energy Secretary Bodman launched his Easy Ways to Save Energy campaign with a promise to provide energy assessments to 200 of the largest U.S. manufacturing plants. DOE's Industrial Technologies Program (ITP) responded to the Secretary's campaign with its Save Energy Now initiative, featuring a new and highly cost-effective form of energy savings assessment. The approach for these assessments drew heavily on the existing resources of ITP's technology delivery component. Over the years, ITP Technology Delivery has worked with industry partners to assemble a suite of respected software tools, proven assessment protocols, training curricula, certified energy experts, and strong partnerships for deployment. The Save Energy Now assessments conducted in calendar year 2006 focused on natural gas savings and targeted many of the nation's largest manufacturing plants - those that consume at least 1 TBtu of energy annually. The 2006 Save Energy Now assessments focused primarily on assessments of steam and process heating systems, which account for an estimated 74% of all natural gas use by U.S. manufacturing plants. Because of the success of the Save Energy Now assessments conducted in 2006 and 2007, the program was expanded and enhanced in two major ways in 2008: (1) a new goal was set to perform at least 260 assessments; and (2) the assessment focus was expanded to include pumping, compressed air, and fan systems in addition to steam and process heating. DOE ITP also has developed software tools to assess energy efficiency improvement opportunities in pumping, compressed air, and fan systems. The Save Energy Now assessments integrate a strong training component designed to teach industrial plant personnel how to use DOE's opportunity assessment software tools. This approach has the advantages of promoting strong buy-in of plant personnel for the assessment and its outcomes and preparing them better to independently replicate the assessment process at the company's other facilities. Another important element of the Save Energy Now assessment process is the follow-up process used to identify how many of the recommended savings opportunities from individual assessments have been implemented in the industrial plants. Plant personnel involved with the Save Energy Now assessments are contacted 6 months, 12 months, and 24 months after individual assessments are completed to determine implementation results. A total of 260 Save Energy Now assessments were successfully completed in calendar year 2008. This means that a total of 718 assessments were completed in 2006, 2007, and 2008. As of July 2009, we have received a total of 239 summary reports from the ESAs that were conducted in year 2008. Hence, at the time that this report was prepared, 680 final assessment reports were completed (200 from year 2006, 241 from year 2007, and 239 from year 2008). The total identified potential cost savings from these 680 assessments is $1.1 billion per year, including natural gas savings of about 98 TBtu per year. These results, if fully implemented, could reduce CO{sub 2} emissions by about 8.9 million metric tons annually. When this report was prepared, data on implementation of recommended energy and cost savings measures from 488 Save Energy Now assessments were available. For these 488 plants, measures saving a total of $147 million per year have been implemented, measures that will save $169 million per year are in the process of being implemented, and plants are planning implementation of measures that will save another $239 million per year. The implemented recommendations are already achieving total CO{sub 2} reductions of about 1.8 million metric tons per year. This report provides a summary of the key results for the Save Energy Now assessments completed in 2008; details of the 6-month, 12-month, and 24-month implementation results obtained to date; and an evaluation of these implementation results. This report also summarizes key accomplishments, findings, and lessons learned from all the Save Energy Now assessments completed to date. A separate report (Wright et al. 2010) provides more detailed information on key results for all of the 2008 assessments of steam, process heating, pumping, compressed air, and fan systems. Two prior reports (Wright et al. 2007 and Wright et al. 2009) detail the results from the 2006 and 2007 assessments and discuss the major components of the assessment process and improvements in the process made in 2007.

03 NATURAL GAS↗

Direct analysis of cotton swipes for uranium and plutonium isotopic determination by microextraction-ICP-MS

The determination of uranium and plutonium isotopic abundance on environmental samples collected by International Atomic Energy Agency (IAEA) inspectors is vital for the detection of undeclared nuclear activities and material under the international nuclear safeguards regime. Current analytical protocols require time-consuming sample preparation steps prior to subsequent measurement by inorganic mass spectrometry (MS). Recent efforts from this laboratory have focused on developing sample preparation methods for faster analysis, potentially allowing higher sample throughput[1]. Alternative methods including microextraction sampling in conjunction with inductively coupled plasma-mass spectrometry (ICP-MS) have been recently explored. This methodology, microextraction-ICP-MS, was developed such that uranium and plutonium could be extracted from the swipe surface and directed into the ICP-MS for an in-situ measurement, eliminating the need for swipe ashing and digestion. A commercial off-the-shelf microextraction system was customized with an automated movable XY stage that can be programmed to save sampling locations, allowing for automated rapid sampling of swipe surfaces. Additional efforts have focused on the utilization of collision cell technology to the microextraction ICP-MS method. This would eliminate the need for lengthy column chemistry procedures to purify separated uranium and plutonium fractions before analysis. Here, the extracted U/Pu analyte is measured by reacting the uranium ions with CO2 in the collision cell of an ICP-MS, shifting the uranium to UO+, which will not interfere with the plutonium isotopic determination. The developed method utilizing collision cell – ICP-MS technology has demonstrated the ability to measure plutonium isotope ratios in the presence of high uranium concentration on the transient signal from the microextraction system utilizing certified reference materials from JRC-Geel and the New Brunswick Laboratory Program Office.

Bradley, Veronica↗