Search NASA⌕ Search

SEARCH · Search NASA

Results for “array detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,189 records · Page 66

A new component of hard X-rays in solar flares

High-resolution (approximately 1 keV FWHM) spectral measurements from 13 to 300 keV of a solar flare hard X-ray burst observed on 1980 June 27 by a balloon-borne array of cooled germanium planar detectors are presented. At energies below about 35 keV, a new component of solar flare hard X-rays is identified. This component is characterized by an extremely steep spectrum which fits closely to that from a Maxwellian electron distribution with a maximum temperature of about 34 x 10 to the 6th K and an emission measure of 2.9 x 10 to the 48th per cu cm. This hot isothermal component appears at the peak of the normal power-law-like impulsive X-ray burst component, and it remains isothermal and dominates the X-ray emission below about 30 keV through the decay of the flare event.

Lin, R. P.↗

Integrating 128-element linear imager for the 1 to 5 microns region

Useful charge integration has been achieved in high quality photovoltaic InSb diodes when combined with a FET multiplexing (MUX) scheme. An experimental detector assembly with a linear array of 128 InSb diodes coupled to a FEX MUX has been developed. The first stage J-FET preamp, pixel reset switch, MUX, and the InSb array are contained in a hybrid microcircuit of compact dimensions. A low noise preamplifier topology which capitalizes on the low video line capacitance inherent with hybrid fabrication techniques is also utilized. Measurements indicate a signal-to-noise ratio of over 1000:1 and response uniformity of + or - 2 percent. Sample images show subtle detail which supports the estimated radiometric sensitivity of 0.01 K.

Bailey, G. C.↗

Design and verification of a cloud field optical simulator

A concept and an apparatus designed to investigate the reflected and transmitted distributions of light from optically thick clouds is presented. The Cloud Field Optical Simulator (CFOS) is a laboratory device which utilizes an array of incandescent lamps as a source, simulated clouds made from cotton or styrofoam as targets, and an array of silicon photodiodes as detectors. The device allows virtually any source-target-detector geometry to be examined. Similitude between real clouds and their CFOS cotton or styrofoam counterparts is established by relying on a linear relationship between optical depth and the ratio of reflected to transmitted light for a semiinfinite layer. Comparisons of principal plane radiances observed by the CFOS with Monte Carlo computations for a water cloud at 0.7 micron show excellent agreement. Initial applications of the CFOS are discussed.

Davis, J. M.↗

Design and verification of a cloud field optical simulator

A concept and an apparatus designed to investigate the reflected and transmitted distributions of light from optically thick clouds is presented. The Cloud Field Optical Simulator (CFOS) is a laboratory device which utilizes an array of incandescent lamps as a source, simulated clouds made from cotton or styrofoam as targets, and an array of silicon photodiodes as detectors. The device allows virtually any source-target-detector geometry to be examined. Similitude between real clouds and their CFOS cotton or styrofoam counterparts is established by relying on a linear relationship between optical depth and the ratio of reflected to transmitted light for a semi-infinite layer. Comparisons of principal plane radiances observed by the CFOS with Monte Carlo computations for a water cloud at 0.7 microns show excellent agreement.

Davis, J. M.↗

High resolution hard X-ray spectra of solar and cosmic sources

High resolution hard X-ray observations of a large solar flare and the Crab Nebula were obtained during balloon flights using an array of cooled germanium planar detectors. In addition, high time resolution high sensitivity measurements were obtained with a 300 square cm NaI/CsI phoswich scintillator. The Crab spectrum from both flights was searched without finding evidence of line emission below 200 keV. In particular, for the 73 keV line previously reported a 3 sigma upper limit for a narrow (1 keV FWHM) line .0019 and .0014 ph square cm/sec for the 1979 and 1980 flights, respectively was obtained.

Schwartz, R. A.↗

Plans for a fast image recording system at ESO

A 256 diode-array will be installed as detector on the ESO OPTRONICS S-3000 measuring machine in order to increase the acquisition rate. A high intensity LED will be used as light source in a pulse mode. The data will be stored on a random access mass storage device as density values for later education. The scanning time for a 30 cm x 30 cm plate with a step size of 10 micron will be less than 10 hours while the dynamic range of the data is expected to be 2.5 density units with an offset of at least 1 unit.

Grosboel, P. J.↗

Observation of EAS using a large water tank

Using a large water tank (30 m in diameter, 4.5 m in depth) transition of extensive air showers (EAS) was investigated at Taro (200 m above sea level). There are set 150,0.4 sq m proportional counters on the bottom of the water tank. A conventional EAS array of 25 plastic scintillation detectors was arranged within several tens meter from the water tank. A proportional counter (10x10x200 cc x2) is made of a square shaped pipe of iron. Tungsten wire (100 mu m phi) is stretched tight in the center of the counter. A gas mixture of 90% argon and 10% methane is used at 760 mmHg. About 3000 EAS were obtained through 1 m of water since 1984.

Inoue, K.↗

The thickness of the shower disc as observed in showers produced by primaries above 10 (19)eV

The thickness of the shower disk has been measured in showers initiated by primaries of energy to 10 the 19th power eV using the large area water Cerenkov detectors of the Haverah Park array. Results are presented which (1) provide supporting evidence for the accuracy of analysis procedures in giant showers, (2) offer an evaluation of the mini-array technique for the detection of giant showers and (3) extend earlier work on developmental fluctuations above 10 to the 19th power eV.

Lawrence, M. A.↗

A faint object spectrometer for the infrared

A cryogenic astronomical spectrometer for the NASA Infrared Telescope Facility is described. This spectrometer will employ an array of at least 20 detectors and provide a resolving power of 100 to 1500 at 1-5 microns. The resolving power will be adjustable by changing gratings.

Tokunaga, A. T.↗

Composition of faint comets

The study uses an emission line, differential imaging camera built by the Science Operations Branch. This instrument allows photometric data to be obtained over a large area of a comet in a large number of resolution elements. The detector is a 100x100 Reticon array which with interchangeable optics can give resolutions from 2" to 30" over a field of 1' to 15'. The camera through its controlling computer can simultaneously take images in on-line and continuum filters and through computer subtraction and calibration present a photometric image of the comet produced by only the emission of the molecule under study. Initial work has shown two significant problems. First the auxiliary equipment of the telescope has not allowed the unambiguous location of faint comets so that systematic observations could be made, and secondly initial data has not shown much molecular emission from the faint comets which were located. Work last year on a software and hardware display system and this year on additional guide motors on the 36-inch telescope has allowed the differential camera to act as its own finder and guide scope. Comet IRAS was observed in C2 and CO+, as well as an occultation by the comet of SAO029103. The perodic comet Giacobini-Zinner was also observed in C2.

Brown, L. W.↗

A study of Si:In hybrid surface channel IRCCD devices

Hybrid silicon Infrared Charge Coupled Devices (IRCCDs) are evaluated for use as viable astronomical detectors. A Si:In photoconductor array which is bump-bonded to a silicon multiplexer is described. A summary of the device parameters is given.

Tollestrup, E.↗

Method of fabricating an imaging X-ray spectrometer

A process for fabricating an X-ray spectrometer having imaging and energy resolution of X-ray sources is discussed. The spectrometer has an array of adjoinging rectangularly shaped detector cells formed in a silicon body. The walls of the cells are created by laser drilling holes completely through the silicon body and diffusing n(+) phosphorous doping material therethrough. A thermally migrated aluminum electrode is formed centrally through each of the cells.

Alcorn, G. E.↗

Evaluation of Airborne Visible/Infrared Imaging Spectrometer Data of the Mountain Pass, California carbonatite complex

Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) data of the Mountain Pass, California carbonatite complex were examined to evaluate the AVIRIS instrument performance and to explore alternative methods of data calibration. Although signal-to-noise estimates derived from the data indicated that the A, B, and C spectrometers generally met the original instrument design objectives, the S/N performance of the D spectrometer was below expectations. Signal-to-noise values of 20 to 1 or lower were typical of the D spectrometer and several detectors in the D spectrometer array were shown to have poor electronic stability. The AVIRIS data also exhibited periodic noise, and were occasionally subject to abrupt dark current offsets. Despite these limitations, a number of mineral absorption bands, including CO3, Al-OH, and unusual rare earth element bands, were observed for mine areas near the main carbonatite body. To discern these bands, two different calibration procedures were applied to remove atmospheric and solar components from the remote sensing data. The two procedures, referred to as the single spectrum and the flat field calibration methods gave distinctly different results. In principle, the single spectrum method should be more accurate; however, additional fieldwork is needed to rigorously determine the degree of calibration success.

Crowley, James↗

Visible and infrared mapping spectrometer (VIMS) - A facility instrument for planetary missions

A second-generation visible and IR mapping spectrometer (VIMS), selected for both the Mars Observer and Comet Rendezvous Asteroid Flyby (CRAF) missions, is described. VIMS is a scanning spectrometer with a focal plane consisting of linear arrays of visible and IR detectors, cooled by a radiative cooler. It is noted that a wide-angle scan using a full-aperture scan mirror was implemented for the Mars Observer; a narrow-angle scan using a scanning secondary mirror within a Cassegrain foreoptic was achieved for the CRAF mission.

Wellman, John B.↗

Heavy Nucleus Collector (HNC) project for the NASA Long Duration Exposure Facility (LDEF)

The primary goal of the heavy nucleus collector (HNC) experiment was to obtain high resolution composition measurements for cosmic ray nuclei in the platinum-lead and actinide region of the periodic table. Secondary objectives include studies of selected groups of elements of lower charge. These goals were to be realized by orbiting a large area array of dielectric nuclear track detectors in space for several years. In this time sufficient actinide nuclei would be collected to determine the nucleosynthetic age of the cosmic radiation and the relative mix of r- and s-process elements in the cosmic ray source. The detector consists of approximately 50 trays assembled in pressurized canisters. Each tray would contain 8 half-stacks (4 stacks total) and an event thermometer which would record the temperature of each event at the time of exposure. Each stack would contain 7 layers of Rodyne-P, CR-39 and Cronar plastic track detectors interleaved with copper stripping foils. Upon return to Earth, detectors would be removed for analysis. Ultraheavy nuclei would have left tracks through the detector sheets that would be made visible after etching in a hot sodium hydroxide solution.

Tarle, Gregory↗

Hot plasma and energetic particles in Neptune's magnetosphere

Voyager 2's low energy charged particle instrument employed an array of solid-state detectors in various configurations to measure energetic electrons and ions within the Neptune magnetosphere in several energy channels. Various features of the intensity, spectral, and anisotropic data obtained suggest that the Triton satellite exerts an important controlling influence over the outer regions of the Neptunian magnetosphere. Composition measurements have indicated the presence of H, H2, and He-4 at 1300:1:0.1 relative abundances, respectively, suggesting a Neptunian ionospheric source for the trapped particle population.

Krimigis, S. M.↗

The Nuclear Astrophysics Explorer

The Nuclear Astrophysics Explorer (NAE) is a concept for a possible future NASA Explorer mission which would obtain high resolution, E/Delta E about 500, observations of gamma-ray lines in order to study many fundamental problems in astrophysics. It operates from 15 keV to 10 MeV with a 3-sigma sensitivity of about 3 x 10 to the -6th ph/sq cm-s in a 10 to the 6th s observation. This is 100 times below the presently known gamma-ray line fluxes. The NAE uses a heavily shielded array of nine cooled Ge detectors in a very low background configuration. Its 10-deg field of view contains a versatile coded mask system which provides 2D imaging with 4-deg resolution, 1D imaging with 2-deg resolution and efficient measurements of emission from diffuse and point sources. The late 1990s is the earliest the NAE mission could begin. The scientific motivation, instrument concept, mission concept and expected results, and status and plans for the NAE are presented.

Matteson, James L.↗

EXOSS - A hard X-ray and soft gamma-ray astronomy mission

The Energetic X-ray Observatory on Space Station (EXOSS) is a mission concept for high-sensitivity coded-aperture sky surveys and studies of the spectral and temporal behavior of astrophysical sources from approximately 3 keV to 1 MeV. The scientific motivation for the mission and the instrument requirements, including the need for high angular resolution to resolve and identify numerous detectable sources, are summarized. Two baseline telescopes are described: one employing a 1.4-sq-m array of Xe gas imaging proportional counters to cover the 3 to 100 keV range with 1 arcmin resolution; the second using a 2.8-sq-m array of NaI/CsI imaging phoswich detectors to span the 20 keV to MeV range with 12 arcmin resolution.

Cook, W. R.↗