Search NASA⌕ Search

SEARCH · Search NASA

Results for “array detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,189 records · Page 66

Characterization of Non-uniformities in Superconducting Tunnel Junction Radiation Detectors

The small dimensions of superconducting tunnel junction (STJ) radiation detectors have motivated the development of STJ arrays to increase detection efficiency and statistical accuracy. We have used a pulsed UV laser and X-rays to characterize and understand non-uniformities in the response of different pixels in Ta-based STJ arrays. To separate the contributions of the detector and the readout electronics, we have also injected the pulses from an arbitrary waveform generator into the array’s amplifier chain. We discuss the magnitude and the sources of the non-uniformity and approaches to reduce it.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Design, upgrade and characterization of the silicon photomultiplier front-end for the AMIGA detector at the Pierre Auger Observatory

AMIGA (Auger Muons and Infill for the Ground Array) is an upgrade of the Pierre Auger Observatory to complement the study of ultra-high-energy cosmic rays (UHECR) by measuring the muon content of extensive air showers (EAS). It consists of an array of 61 water Cherenkov detectors on a denser spacing in combination with underground scintillation detectors used for muon density measurement. Each detector is composed of three scintillation modules, with 10 m 2 detection area per module, buried at 2.3 m depth, resulting in a total detection area of 30 m 2 . Silicon photomultiplier sensors (SiPM) measure the amount of scintillation light generated by charged particles traversing the modules. In this paper, the design of the front-end electronics to process the signals of those SiPMs and test results from the laboratory and from the Pierre Auger Observatory are described. Compared to our previous prototype, the new electronics shows a higher performance, higher efficiency and lower power consumption, and it has a new acquisition system with increased dynamic range that allows measurements closer to the shower core. The new acquisition system is based on the measurement of the total charge signal that the muonic component of the cosmic ray shower generates in the detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Gamma-Ray Spectroscopy at TRIUMF-ISAC: the New Frontier of Radioactive Ion Beam Research

High-resolution gamma-ray spectroscopy is essential to fully exploit the unique scientific opportunities at the next generation radioactive ion beam facilities such as the TRIUMF Isotope Separator and Accelerator (ISAC). At ISAC the 8{pi} spectrometer and its associated auxiliary detectors is optimize for {beta}-decay studies while TIGRESS an array of segmented clover HPGe detectors has been designed for studies with accelerated beams. This paper gives a brief overview of these facilities and also presents recent examples of the diverse experimental program carried out at the 8{pi} spectrometer.

43 PARTICLE ACCELERATORS↗

Operation of the Fast Neutron Coincidence Collar (FNCL) with a DD-Neutron Generator

For more than 30 years, the quantitative assay of the 235 U content of light water reactor fresh fuel assemblies relied on measuring coincidence neutrons from fissions induced by an Am(Li) neutron source using 3 He based detectors. The Fast Neutron Collar (FNCL) developed by the International Atomic Energy Agency (IAEA), replaces traditional 3 He proportional counters with an array of liquid scintillator detectors arranged about the fuel assembly to provide improved measurement precision and reduced sensitivity to gadolinium poison rods. The FNCL relies on Am(Li) neutron sources that are no longer commercially available. This work examines the replacement of Am(Li) sources with a commercial off the-shelf deuterium–deuterium (DD) neutron generator. In addition to mitigating supply concerns, the neutron generator offers advantages in measurement precision and potential automation of sequential passive/active neutron measurements. This report presents the initial performance results for both the integrated DD/FNCL and Am(Li)/FNCL assays of compact depleted uranium, low-enriched uranium, and highly enriched uranium standards along with an estimate of the expected performance for fresh fuel assemblies. A discussion of the design and operation of the “FNCL Analysis and Simulation Software” is also provided.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Multi-element CZT array for nuclear safeguards applications

To address drawbacks of a CZT detector due to its limited size, a dual-CZT array, consisting of two CZT detectors and a DAS (Data Acquisition System), was constructed and algorithm to handle the spectra from the CZT array was discussed in this study. Spectra of 4.5% enriched UO{sub 2} powder were obtained using the dual-CZT array. The detection efficiency acquired by the CZT array was about twice higher than that of a single CZT spectra, while FWHMs are nearly identical (about 7.0 keV) for each spectrum. The results of this study show that a much better detection efficiency of CZT can be achieved without degrading its energy resolution. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A measurement of the 2 neutrino double beta decay rate of Te-130 in the CUORICINO experiment

CUORICINO was a cryogenic bolometer experiment designed to search for neutrinoless double beta decay and other rare processes, including double beta decay with two neutrinos (2vββ). The experiment was located at Laboratori Nazionali del Gran Sasso and ran for a period of about 5 years, from 2003 to 2008. The detector consisted of an array of 62 TeO 2 crystals arranged in a tower and operated at a temperature of 10 mK. Events depositing energy in the detectors, such as radioactive decays or impinging particles, produced thermal pulses in the crystals which were read out using sensitive thermistors. The experiment included 4 enriched crystals, 2 enriched with 130 Te and 2 with 128 Te, in order to aid in the measurement of the 2vββ rate. The enriched crystals contained a total of 350 g 130 Te. The 128-enriched (130-depleted) crystals were used as background monitors, so that the shared backgrounds could be subtracted from the energy spectrum of the 130- enriched crystals. Residual backgrounds in the subtracted spectrum were fit using spectra generated by Monte-Carlo simulations of natural radioactive contaminants located in and on the crystals. The 2vββ half-life was measured to be T 2v 1/2 = [9.81± 0.96(stat)± 0.49(syst)] x10 20 y.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

X-ray analysis of electron Bernstein wave heating in MST

A pulse height analyzing x-ray tomography system has been developed to detect x-rays from electron Bernstein wave heated electrons in the Madison symmetric torus reversed field pinch (RFP). Cadmium zinc telluride detectors are arranged in a parallel beam array with two orthogonal multi-chord detectors that may be used for tomography. In addition a repositionable 16 channel fan beam camera with a 55° field of view is used to augment data collected with the Hard X-ray array. The chord integrated signals identify target emission from RF heated electrons striking a limiter located 12° toroidally away from the RF injection port. This provides information on heated electron spectrum, transport, and diffusion. RF induced x-ray emission from absorption on harmonic electron cyclotron resonances in low current (<250 kA) RFP discharges has been observed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Detector and Readout Assembly and Characterization for the Simons Array

The Simons Array (SA) is a cosmic microwave background (CMB) polarization experiment comprised of three telescopes that will observe the CMB at 90, 150, 220, and 270GHz with more than 22,000 Transition Edge Sensor (TES) bolometers. The cryogenic receivers inside each telescope are named POLARBEAR-2a, POLARBEAR-2b, and POLARBEAR-2c (PB-2a, PB-2b, and PB-2c, respectively). To allow for the large number of detectors, SA uses frequency-division multiplexing with multiplexing factor of 40. We describe the process developed to assemble the readout circuit repeatably for SA. After assembly, we characterize the readout circuit and TESs at cryogenic temperatures in a condition of negligible incident optical power. Impedances in the readout circuit bias our estimates of TES parameters, and we describe a method to account for this.

cosmic microwave background↗

Multi-element germanium detectors for synchrotron applications

In this paper, we have developed a series of monolithic multi-element germanium detectors, based on sensor arrays produced by the Forschungzentrum Julich, and on Application-specific integrated circuits (ASICs) developed at Brookhaven. Devices have been made with element counts ranging from 64 to 384. These detectors are being used at NSLS-II and APS for a range of diffraction experiments, both monochromatic and energy-dispersive. Compact and powerful readout systems have been developed, based on the new generation of FPGA system-on-chip devices, which provide closely coupled multi-core processors embedded in large gate arrays. Finally, we will discuss the technical details of the systems, and present some of the results from them.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Antenna-coupled microcavities for enhanced infrared photo-detection

We demonstrate mid-infrared detectors embedded into an array of double-metal nano-antennas. The antennas act as microcavities that squeeze the electric field into thin semiconductor layers, thus enhancing the detector responsivity. Furthermore, thanks to the ability of the antennas to gather photons from an area larger than the device's physical dimensions, the dark current is reduced without hindering the photo-generation rate. In these devices, the background-limited performance is improved with a consequent increase of the operating temperature. Our results illustrate how the antenna-coupled microcavity concept can be applied to enhance the performances of infrared opto-electronic devices.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Gamma Ray Multiplicity of 252Cf Spontaneous Fission using LiBerACE

We are studying the gamma ray and neutron multiplicity of various fission processes, beginning with the spontaneous fission of {sup 252}Cf, for a variety of basic and applied science purposes. The Livermore-Berkeley Array for Collaborative Experiments (LiBerACE) consists of six high-purity germanium Clover detectors (HPGe) each enclosed by an array of 16 bismuth-germanate (BGO) detectors. These detectors were arranged in a cubic pattern around a 1 {micro}Ci {sup 252}Cf source to attempt to cover as much solid angle of gamma ray emission as possible with a high level of segmentation. The single-gamma detector response function is determined at several energies by tagging in a HPGe detector on the photopeak of one of two gamma rays in two-gamma ray calibration sources and observing the multiplicity of the remainder of the array. Summing these single-gamma responses in groups yields the response function of the array to higher multiplicity events, which are convolved with multiplicity distributions from theoretical models and compared to the measured results to test the models validity.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Commercially Fabricated Low Loss Superconducting Resonators Integrated With Detectors for Frequency Domain Multiplexing Readout of Future Cosmic Microwave Background Experiments

Planned Stage-IV cosmic microwave background (CMB) experiments call for telescopes with the order of 500 000 transition edge sensor (TES) bolometers. Such large arrays would benefit from detector multiplexing, as well as miniaturization and integration of readout components. Additionally, fabrication of micro-fabricated devices at a commercial foundry could potentially boost production rate and reduce overall cost. To this end, HYPRES, Inc., LBNL, and U.C. Berkeley are developing low loss, superconducting LC resonators integrated with antenna coupled TES bolometers for frequency multiplexing readout. The resonators are fabricated on the same wafer and are in the same process flow as the TES detectors, reducing size, weight, and wiring complexity of a detector module compared to the conventional design, where each component is fabricated separately. We have fabricated and tested resonators from 0.6 to 70 MHz, both as standalone devices and integrated with TES bolometers, all fabricated on 150- mm wafers. Finally, we discuss the design and fabrication of these devices and present measurements of the standalone resonators.

47 OTHER INSTRUMENTATION↗

DARHT-II Beam Position Monitor B-Dot Owner’s Manual

Azimuthal arrays of magnetic and electric field detectors are used to measure the position of the centroid of the DARHT relativistic electron beams. These arrays consist of four detectors with 90-degree azimuthal separation. Differencing the opposing detectors and normalizing to the sum of all four gives the position of the beam, subject to negligibly small errors as discussed in Attachment A. This measurement yields the centroid of the current density, independent of the beam azimuthal asymmetry.

42 ENGINEERING↗

Hierarchical Phased-Array Antennas Coupled to Al KIDs: A Scalable Architecture for Multi-band Millimeter/Submillimeter Focal Planes

We present the optical characterization of two-scale hierarchical phased-array antenna kinetic inductance detectors (KIDs) for millimeter/submillimeter wavelengths. Our KIDs have a lumped-element architecture with parallel plate capacitors and aluminum inductors. The incoming light is received with a hierarchical phased array of slot dipole antennas, split into 4 frequency bands (between 125 GHz and 365 GHz) with on-chip lumped-element band-pass filters, and routed to different KIDs using microstriplines. Individual pixels detect light for the 3 higher-frequency bands (190–365 GHz), and the signals from four individual pixels are coherently summed to create a larger pixel detecting light for the lowest frequency band (125–175 GHz). The spectral response of the band-pass filters was measured using Fourier transform spectroscopy (FTS), the far-field beam pattern of the phased-array antennas was obtained using an infrared source mounted on a 2-axis translating stage, and the optical efficiency of the KIDs was characterized by observing loads at 294 K and 77 K. We report on the results of these three measurements.

47 OTHER INSTRUMENTATION↗

Feasibility of an Active Interrogation System to Classify Waste with He-4 Neutron Spectroscopy

This work investigates a 4 He-detector active interrogation system that leverages neutron spectroscopy to classify nuclear waste streams. MCNP models tested the concept through the simulation of a D-D neutron generator, an array of 4 He detectors, and various waste compositions. The fast-neutron Differential Die-Away signature was augmented with a neutron-energy discrimination signature. This signature isolates induced fission neutrons, the energy of which is greater than that of the D-D monoenergetic spectrum. With the incorporation of this spectroscopic technique, the measurement time decreased by 3–9% (depending on the degree of neutron moderation and absorption presented by the sample), demonstrating how neutron spectroscopy can enhance active interrogation methods. The reduced measurement times would have significant financial and logistical benefits for facilities with large footprints of low-level waste production.

4He detectors↗

System Modeling and Design Optimization for a Next-Generation Unattended Sensor

We are developing a next-generation unattendedsensor that can detect and identify radiation sources while operating on battery power for several weeks. The system achieves smaller size and weight over systems that use NaI:Tl and 3He detectors by using a relatively new scintillator, Cs2LiYCl6:Ce:Ce (CLYC). This material can detect both gamma rays and thermal neutrons, has energy resolution of ~4% full width at half maximum at 662 keV, and allows for particle discrimination by pulse amplitude as well as pulse shape. The overall design features an array of sixteen CLYC detectors, each read out by a photomultiplier tube and custom pulse processing electronics. A field-programmable gate array analyzes the energy spectra using computationally efficient algorithms for anomaly detection.

McDonald, Benjamin S.↗

Techniques for the measurement of disruption halo currents in the National Spherical Torus Experiment

This paper describes techniques for measuring halo currents, and their associated toroidal peaking, in the National Spherical Torus Experiments [M. Ono et al., Nucl. Fusion 40, 557 (2000)]. The measurements are based on three techniques: (1) measurement of the toroidal field created by the poloidal halo current, either with segmented Rogowski coils or discrete toroidal field sensors, (2) the direct measurement of halo currents into specially instrument tiles, and (3) small Rogowski coils placed on the mechanical supports of in-vessel components. For the segmented Rogowski coils and discrete toroidal field detectors, it is shown that the toroidal peaking factor inferred from the data is significantly less than the peaking factor of the underlying halo current distribution, and a simple model is developed to relate the two. For the array of discrete toroidal field detectors and small Rogowski sensors, the compensation steps that are used to isolate the halo current signal are described. The electrical and mechanical design of compact under-tile resistive shunts and mini-Rogowski coils is described. Example data from the various systems are shown.

42 ENGINEERING↗

CUORE: The first bolometric experiment at the ton scale for the search for neutrino-less double beta decay

The Cryogenic Underground Observatory for Rare Events (CUORE) is the most massive bolometric experiment searching for neutrino-less double beta (0νββ) decay. The detector consists of an array of 988 TeO 2 crystals (742 kg) arranged in a compact cylindrical structure of 19 towers. Here, this paper will describe the CUORE experiment, including the cryostat, and present the detector performance during the first year of running. Additional detail will describe the effort made in improving the energy resolution in the 130 Te 0νββ decay region of interest (ROI) and the suppression of backgrounds. A description of work to lower the energy threshold in order to give CUORE the sensitivity to search for other rare events, such as dark matter, will also be provided.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗