Search NASA⌕ Search

SEARCH · Search NASA

Results for “atomically precise”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,189 records · Page 66

Quantum Enhanced Technologies

Quantum effects have a wide variety of applications in computation, communication, and metrology. To explore practical quantum enhanced technologies, we are investigating quantum metrology in neutral atom systems, such as inertial sensors and clocks, which could revolutionize the field of precision navigation. The lower noise boundary on measurements of a two-level quantum system is given by the standard quantum limit (SQL). This limits the signal-to-noise ratio (SNR) to SNR = $\sqrt{N}$ where N is the number of atoms. Using Quantum Non-Demolition techniques (QND), it has been demonstrated that one can surpass the SQL, with the ultimate limit given by the Heisenberg Limit of SNR = N . For many implementations, this limit corresponds to an improvement by several orders of magnitude. However, achieving even the SQL is difficult in practical systems. To realize the gains of quantum enhanced metrology one must first realize high fidelity measurements of quantum systems. This fidelity is often limited by sources of technical noise in the system which must be characterized and mitigated. In this report we attempt to experimentally reach the SQL in a system of laser-cooled Rubidium 87 atoms. Atomic transitions were induced through microwave radiation and the stimulated Raman interaction. We characterize the various sources of noise that hinder the achievement of the SQL and compare our measurements to theoretical models that take these impediments into consideration. Additionally, we survey the literature for spin-squeezing techniques which allow for Heisenberg-limited measurements in similar cold-atom systems. Our investigation confirmed the difficulty of achieving even moderate amounts of squeezing for a metrologically relevant quantity. However, spin squeezing could prove to be an important technique for atom interferometry if substantial improvements in implementation are made. This work is done in collaboration with the University of New Mexico.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Atomic Ordering-Induced Ensemble Variation in Alloys Governs Electrocatalyst On/Off States

The catalytic behavior of a material is influenced by ensembles—the geometric configuration of atoms. Traditional approaches, mainly utilizing solid-solution alloys in electrocatalysis, have often overlooked the challenges posed by concurrent changes in the electronic structure (i.e. d-band center) when the composition is altered. Here, this study introduces a methodology that distinctly separates the geometric effects (i.e. ensembles) from the electronic structure. We compare the reactivity of compositionally identical, but structurally different Pd 3 Bi ordered intermetallic and solid-solution alloys. Remarkably, we find that Pd 3 Bi intermetallics display nearly no reactivity for the methanol oxidation (MOR), while their solid-solution counterparts have significant reactivity. This highlights a unique case where materials with identical chemical compositions demonstrate drastically different catalytic behavior underscoring the critical importance of ensembles in electrocatalysis. Specifically, Pd 3 Bi intermetallics form smaller ensembles (average coordination number: 4.5 ± 1.6) with almost no measurable MOR activity at room temperature, in contrast to the solid-solution Pd 3 Bi that exhibit larger ensembles (average coordination number: 6.8 ± 0.9) and considerable MOR reactivity (0.5 mA cm −2 Pd ). An ordered Pd 3 Bi alloy, with an intermediate ensemble size (average coordination number: 5.3 ± 1.2), displays moderate MOR activity (0.1 mA cm −2 Pd ), further confirming the direct correlation between ensemble size and catalytic activity. Notably, all Pd 3 Bi alloys maintain similar electronic structures, because the chemical composition of the alloys is fixed, indicating that the differences in reactivity are predominantly from changes to the ensemble size. Our findings offer an approach for precisely controlling catalytic activity through manipulating the geometric configuration of the atoms within an alloy, paving the way for more efficient catalyst design.

alloys↗

FPGA-Based Networked Phasemeter for a Heterodyne Interferometer

A document discusses a component of a laser metrology system designed to measure displacements along the line of sight with precision on the order of a tenth the diameter of an atom. This component, the phasemeter, measures the relative phase of two electrical signals and transfers that information to a computer. Because the metrology system measures the differences between two optical paths, the phasemeter has two inputs, called measure and reference. The reference signal is nominally a perfect square wave with a 50- percent duty cycle (though only rising edges are used). As the metrology system detects motion, the difference between the reference and measure signal phases is proportional to the displacement of the motion. The phasemeter, therefore, counts the elapsed time between rising edges in the two signals, and converts the time into an estimate of phase delay. The hardware consists of a circuit board that plugs into a COTS (commercial, off-the- shelf) Spartan-III FPGA (field-programmable gate array) evaluation board. It has two BNC inputs, (reference and measure), a CMOS logic chip to buffer the inputs, and an Ethernet jack for transmitting reduced-data to a PC. Two extra BNC connectors can be attached for future expandability, such as external synchronization. Each phasemeter handles one metrology channel. A bank of six phasemeters (and two zero-crossing detector cards) with an Ethernet switch can monitor the rigid body motion of an object. This device is smaller and cheaper than existing zero-crossing phasemeters. Also, because it uses Ethernet for communication with a computer, instead of a VME bridge, it is much easier to use. The phasemeter is a key part of the Precision Deployable Apertures and Structures strategic R&D effort to design large, deployable, segmented space telescopes.

Rao, Shanti↗

Atomic-Scale Mechanism of Unidirectional Oxide Growth

A basic knowledge of the unidirectional growth mechanisms is required for precise control on size, shape, and thereby functionalities of nanostructures. The oxidation of many metals results in oxide nanowire growth with a bicrystal grain boundary along the axial direction. Using transmission electron microscopy that spatially and temporally resolves CuO nanowire growth during the oxidation of copper, here we provide direct evidence of the correlation between unidirectional crystal growth and bicrystal grain boundary diffusion. Based on atomic scale observations of the upward growth at the nanowire tip, oscillatory downward growth of atomic layers on the nanowire sidewall and the parabolic kinetics of lengthening, bicrystal grain boundary diffusion is the mechanism by which Cu ions are delivered from the nanowire root to the tip. Together with density-functional theory calculations, we further show that the asymmetry in the corner-crossing barriers promotes the unidirectional oxide growth by hindering the transport of Cu ions from the nanowire tip to the sidewall facets. We anticipate the broader applicability of these results in manipulating the growth of nanostructured oxides by controlling the bicrystal grain boundary structure that favors anisotropic diffusion for unidirectional, one-dimensional crystal growth for nanowires or isotropic diffusion for two-dimensional platelet growth.

36 MATERIALS SCIENCE↗

Angle-Resolved Spectroscopy of Positronium Emission from a Cu(110) Surface

We report the affinity A Ps of positronium (Ps) atoms for a metal is the negative of the maximum kinetic energy with which Ps is emitted into vacuum when thermalized positrons in a metal encounter the surface. When this quantity is measured by ground state Ps time of flight (TOF), the precision is severely limited by the short triplet state lifetime of 142 ns. By quickly converting the emitted Ps atoms into long-lived Rydberg states, we are able to dramatically increase the TOF to allow precision measurements of A Ps . From our measurements made on a Cu(110) sample at T = 128 K, we find A Ps (128 K) = (-2.476±0.010 stat ±0.013 syst ) eV, compared with the result A Ps (128 K) = (-2.545±0.010 stat ±0.010 syst ) eV found using highly accurate generalized gradient approximations for both electrons and positrons within density functional theory. Such precision opens up opportunities in the quest for an improved density functional.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Magic ratio of window width to grating period for van der Waals potential measurements using material gratings

We report improved precision measurements of the van der Waals potential strength (C{sub 3}) for Na atoms and a silicon-nitride (SiN{sub x}) surface. We studied diffraction from nanofabricated gratings with a particular 'magic' open fraction that allows us to determine C{sub 3} without the need for separate measurements of the width of the grating openings. Therefore, finding the magic open fraction improves the precision of C{sub 3} measurements. The same effect is demonstrated for a grating with an arbitrary open fraction by rotating it to a particular 'magic' angle, yielding C{sub 3}=3.42+-0.19 eV A{sup 3} for Na and a SiN{sub x} surface. This precision is sufficient to detect a change in C{sub 3} due to a thin metal coating on the grating surface. We discuss the contribution to C{sub 3} of core electrons and edge effects.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Precision of ENDF and ENDL Formatted Data Files

The purpose is to ensure that today’s processing codes produced output to meet today’s accuracy needs. Since 1958 ENDL and about 1965 ENDF have each used a text format to define nuclear and atomic data in 11 columns for each data field. When these formats originated this was judged to be adequate to reproduce the accuracy of data at the time and to meet the needs of our applications. When these formats originated the dominant computer language of the day was FORTRAN and if written using an E11.4 format it would include only 4 or 5 digits of precision, e.g., 0.1234E-03 or 1.2345E-02, varying from one computer/system to another the result was not even unique. In the case of ENDF the 4 digit precision was not even adequate to uniquely define the atomic weight of the target, e.g., U238 = 92238 = 0.9224E+5 = WRONG! From its inceptions the ENDF format had a precision problem. One of my first tasks when in 1967 fresh out of graduate school I joined what later became the National Nuclear Data Center (NNDC), was to address this precision problem. By working with ENDF producers and users throughout the U.S. we verified, 1) E or D is not required to define FORTRAN readable numbers, e.g., E+4 or +4 are both o.k. 2) With ENDF energy eV and cross section in barns, 2 digit exponents are almost never required. 3) Since energy is never negative we could use the first of the 11 columns for a digit. Knowing this allowed us to produce ENDF/B-II to 6 or 7 digit precision, e.g., blank, decimal point, 2 or 3 digit exponent, e.g., ^1.23456-12 or ^1.234567-3. Below is an example of the actual ENDF/B-II data released. Note, the date 1970 and the atomic weight, ZA, uniquely defined to 6-digit accuracy, ^9.22350+ 4.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Lattice Interferometer for Laser-Cooled Atoms

We demonstrate an atom interferometer in which atoms are laser cooled into a 1D optical lattice, suddenly released, and later subjected to a pulsed optical lattice. For short pulses, a simple analytical theory predicts the signal. We investigate both short and longer pulses where the analytical theory fails. Longer pulses yield higher precision and larger signals, and we observe a coherent signal at times that can differ significantly from the expected echo time. The interferometer has potential for precision measurements of (Planck constant/2pi)/m{sub A}, and can probe the dynamics of atoms in an optical lattice.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Rosette-scan video-rate atomic force microscopy: Trajectory patterning and control design

We introduce an analysis and a systematic design methodology for a novel nonraster scan method based on a rosette pattern and demonstrate its application in video-rate atomic force microscopy. This pattern is traced when the lateral axes of a parallel kinematic scanner are commanded to follow a combination of two sinusoids with identical amplitudes and different frequencies. We create an internal-model-based controller to enhance the tracking performance of this pattern and implement the scheme on a microelectromechanical system scanner. The conclusions reveal high-precision tracking of the rosette pattern in order to acquire time-lapsed atomic force microscope images at the rate of 10 frames/s.

42 ENGINEERING↗

Dissipation-induced Tonks-Girardeau gas of polaritons

A scheme for the generation of a Tonks-Girardeau (TG) gas of polaritons with purely dissipative interaction is described. We put forward a master equation approach for the description of stationary light in atomic four-level media and show that, under suitable conditions, two-particle decays are the dominant photon loss mechanism. These dissipative two-photon losses increase the interaction strength by at least one order of magnitude as compared to dispersive two-photon processes and can drive the polaritons into the TG regime. Characteristic correlations of the TG gas, including quantities that distinguish it from free fermions, can be measured via standard quantum optical techniques. Our scheme thus allows one to feasibly generate highly correlated photon states, which can be of considerable use in quantum-information processing and precision measurements.

74 ATOMIC AND MOLECULAR PHYSICS↗

Critical aspects of nano-indentation technique in application to hardened cement paste

Several open questions related to the experimental protocol and processing of data acquired by the nano-indentation (NI) technique are investigated. The volume fractions of mechanically different phases obtained from statistical NI (SNI) analysis are shown to be different from those obtained by back-scattered electron (BSE) image analysis and X-ray diffraction (XRD) method on the same paste. Judging from transmission electron microscope (TEM) images, the representative volume element of low-density calcium-silicate hydrates (C-S-H) can be considered to be around 500 nm, whereas for high-density C-S-H it is about 100 nm. This raises the question how the appropriate penetration depth for NI experiments should be selected. Changing the maximum load from 1 mN to 5 mN, the effect of penetration depth on the experimental results is studied. As an alternative to the SNI method, a 'manual' indentation method is proposed, which combines information from BSE and atomic-force microscopy (AFM), coupled to the NI machine. The AFM allows to precisely indent a high-density C-S-H rim around unhydrated clinkers in cement paste. Yet the results from that technique still show a big scatter.

36 MATERIALS SCIENCE↗

Entangling atomic spins with a Rydberg-dressed spin-flip blockade

Controlling the quantum entanglement between parts of a many-body system is key to unlocking the power of quantum technologies such as quantum computation, high-precision sensing, and the simulation of many-body physics. The spin degrees of freedom of ultracold neutral atoms in their ground electronic state provide a natural platform for such applications thanks to their long coherence times and the ability to control them with magneto-optical fields. However, the creation of strong coherent coupling between spins has been challenging. In this paper, we demonstrate a strong and tunable Rydberg-dressed interaction between spins of individually trapped caesium atoms with energy shifts of order 1 MHz in units of Planck’s constant. This interaction leads to a ground-state spin-flip blockade, whereby simultaneous hyperfine spin flips of two atoms are inhibited owing to their mutual interaction. Finally, we employ this spin-flip blockade to rapidly produce single-step Bell-state entanglement between two atoms with a fidelity ≥81(2)%.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Advancing Photo(Electro)Chemical Water Splitting: The Promise of Atomically Dispersed Single‐, Dual‐, and Alloy‐Site Catalysts

Single-atom catalysts (SACs) have rapidly gained prominence as an emerging class of electrocatalysts for water splitting, owing to their uniform and precisely defined active sites. By maintaining uniform reaction pathways, SACs minimize the formation of unwanted byproducts, thus exhibiting extremely high selectivity and atomic efficiency. A key determinant of SAC performance lies in the interfacial interaction between the isolated metal atoms and the supporting material under strong metal–support coordination, which is vital for maintaining long-term activity. However, despite these benefits, reproducibly synthesizing SACs with high metal loadings while retaining uniform dispersion remains a significant challenge. To address the intrinsic challenges of SACs, recent research has expanded into dual-atom catalysts (DACs) and single-atom alloy catalysts (SAACs), providing synergistic active sites and combining the benefits of SACs with bimetallic systems. Furthermore, this review systematically explores the latest advancements in synthesis methods and innovations for SACs for electrochemical water splitting. Additionally, it examines the evolution of catalyst design, emphasizing the unique structural and electronic characteristics of single-site, dual-site, and alloyed SAC systems and highlighting their critical roles in accelerating water-splitting reaction kinetics as well as the prevailing challenges and outlining promising directions for advancing hydrogen production via water electrolysis.

08 HYDROGEN↗

Optical rotation in excess of 100 rad generated by Rb vapor in a multipass cell

Paramagnetic Faraday rotation is a powerful technique for atom sensing widely used in quantum nondemolition measurements, fundamental symmetry tests, and other precision measurements. We demonstrate the use of a multipass optical cell for Faraday rotation spectroscopy and observe polarization rotation in excess of 100 rad from spin-polarized Rb vapor. Unlike optical cavities, multipass cells have a deterministic number of light passes and can be used to measure large optical rotations. We also observe a tenfold suppression of transverse spin relaxation when Rb atoms are placed in a coherent superposition state immune to spin-exchange collisions.

74 ATOMIC AND MOLECULAR PHYSICS↗

Correlating the three-dimensional atomic defects and electronic properties of two-dimensional transition metal dichalcogenides

The electronic, optical and chemical properties of two-dimensional transition metal dichalcogenides strongly depend on their three-dimensional atomic structure and crystal defects. Using Re-doped MoS 2 as a model system, here we present scanning atomic electron tomography as a method to determine three-dimensional atomic positions as well as positions of crystal defects such as dopants, vacancies and ripples with a precision down to 4 pm. We further measure the three-dimensional bond distortion and local strain tensor induced by single dopants. By directly offering these experimental three-dimensional atomic coordinates to density functional theory, we obtain more accurate electronic band structures than derived from conventional density functional theory calculations that relies on relaxed three-dimensional atomic coordinates. We anticipate that scanning atomic electron tomography not only will be generally applicable to determine the three-dimensional atomic coordinates of two-dimensional materials, but also will enable ab initio calculations to better predict the physical, chemical and electronic properties of these materials.

36 MATERIALS SCIENCE↗

Absolute Geodetic Rotation Measurement Using Atom Interferometry

We demonstrate a cold-atom interferometer gyroscope which overcomes accuracy and dynamic range limitations of previous atom interferometer gyroscopes. We show how the instrument can be used for precise determination of latitude, azimuth (true north), and Earth's rotation rate. Spurious noise terms related to multiple-path interferences are suppressed by employing a novel time-skewed pulse sequence. Extended versions of this instrument appear capable of meeting the stringent requirements for inertial navigation, geodetic applications of Earth's rotation rate determination, and tests of general relativity.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Vapor Phase Installation of CpCo(CO) 2 in MOF‐808

Metal-organic frameworks (MOFs), including MOF-808 present an opportunity for vapor phase installation of reactive centers that may serve as uniform sites for precision catalysis. The mechanism of cobalt installation in MOF-808 through atomic layer deposition (ALD) upon CpCo(CO )2 exposure is investigated through in situ FTIR spectroscopy complemented by density functional theory modeling. The role of subsequent H 2 O exposure in the hydrolysis of carbonyl and cyclopentadienyl ligands to complete the installation is also investigated. In situ FTIR study reveals that upon exposure of CpCo(CO) 2 to MOF-808 at 115 °C, a long-lived, stable intermediate is formed that presents carbonyl stretching vibrations similar to the undissociated precursor that are attributed to multiple chemisorbed carbonyl complexes. In MOF-808, cobalt species are initially absorbed near the BTC linker rather than directly on the nodes, revealing the importance of non-covalent interactions in the installation process. DFT suggests that H 2 O exposure promotes carbonyl elimination but leaves a cyclopentadienyl-capped cobalt that is more stable than the complete hydrolysis product. The simulations are consistent with cobalt installation in MOF-808 using CpCo(CO) 2 and H 2 O at 115 °C and further consistent with the lack of ALD thin film deposition of cobalt oxide thin films on planar supports.

36 MATERIALS SCIENCE↗

Achieving Highly Durable Random Alloy Nanocatalysts through Intermetallic Cores

Pt catalysts are widely studied for the oxygen reduction reaction, but their cost and susceptibility to poisoning limit their use. A strategy to address both problems is to incorporate a second transition metal to form a bimetallic alloy; however, the durability of such catalysts can be hampered by leaching of non-noble metal components. Here, we show that random alloyed surfaces can be stabilized to achieve high durability by depositing the alloyed phase on top of intermetallic seeds using a model system with PdCu cores and PtCu shells. Specifically, random alloyed PtCu shells were deposited on PdCu seeds that were either the atomically random face-centered cubic phase (FCC A1, Fm$\bar{3}$m) or the atomically ordered CsCl-like phase (B2, Pm$\bar{3}$m). Precise control over crystallite size, particle shape, and composition allowed for comparison of these two core@shell PdCu@PtCu catalysts and the effects of the core phase on electrocatalytic durability. Indeed, the nanocatalyst with the intermetallic core saw only an 18% decrease in activity after stability testing (and minimal Cu leaching), whereas the nanocatalyst with the random alloy core saw a 58% decrease (and greater Cu leaching). The origin of this enhanced durability was probed by classical molecular dynamics simulations of model catalysts, with good agreement between model and experiment. Although many random alloy and intermetallic nanocatalysts have been evaluated, this study directly compares random alloy and intermetallic cores for electrocatalysis with the enhanced durability achieved with the intermetallic cores likely general to other core@shell nanocatalysts.

36 MATERIALS SCIENCE↗