New Whole-House Solutions Case Study: Affordable Cold Climate Infill Housing with Hybrid Insulation Approach, Wyandotte, Michigan

Even builders who are relatively new to energy-efficient construction can consistently reach a target whole house airtightness of 1.5 air changes per hour at 50 Pascals (ACH50) with high R-value enclosures that use a hybrid insulation approach. In 2010, the City of Wyandotte, Michigan, started construction to build affordable, energy-efficient homes on lots in existing neighborhoods. A goal was to engage local builders in energy-efficient construction and be able to deliver the new houses for less than $100/ft2. By the end of 2012, approximately 25 new houses were built by five local builders under this program. To help builders consistently achieve the airtightness target, a local architect worked with researchers from Building Science Corporation, a Building America team, to develop a technology specification with several key pieces. A high R-value wall and roof assembly made use of 2 ×6 advanced framing and a hybrid insulation approach that included insulating sheathing to control thermal bridging and closed cell spray polyurethane foam insulation (ccSPF) for its airtightness and vapor control benefits. This approach allows the air barrier to be completed and tested before any finishing work occurs, ensuring that problems are spotted and corrected early in the construction process.

BSC↗

Community College Energy Code Training Program

The U.S. Department of Energy (DOE) Office of Energy Efficiency and Renewable Energy (EERE) funded a series of research and training programs under the Advanced Building Construction with Energy Efficient Technologies and Practices (ABC) initiative. The aim is to develop new training programs to support the development of a skilled workforce in the building energy efficiency industry. In response, the University of Illinois Smart Energy Design Assistance Center (SEDAC), in collaboration with State Energy Offices in Illinois, Hawaii, and Nevada, developed the Community College Energy Code Training Program. The program is designed to prepare a new generation of energy-literate professionals that understand energy efficiency and its relation to energy codes for new construction and existing buildings through: a) the development of a curriculum and innovative pedagogical materials, b) dissemination through a national network of state energy offices: c) outreach targeting Community College students and instructors.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Assessment of the Griffin Reactor Multiphysics Application Using the Empire Micro Reactor Design Concept

In late 2019, INL and ANL agreed to jointly develop the reactor physics code named Griffin based on the integration of the two code suites, MAMMOTH/Rattlesnake (INL) and MC2 - 3/PROTEUS (ANL). Griffin is being developed based on the MOOSE framework and MOOSE quality assurance procedures. This decision was made to be able to allow DOE-NE to efficiently invest funding to this area and to provide effective and timely support for existing and potential users; the latter includes industry and government organizations who are developing various types of advanced reactors in the near and long term. Since MAMMOTH/Rattlesnake has been developed based on the MOOSE framework, the INL/ANL Griffin development team agreed to build Griffin beginning with a merger of MAMMOTH and Rattlesnake into a single code and moving forward by implementing capabilities from the PROTEUS suite into Griffin. Moving forward, both ANL and INL efforts are equally invested in the Griffin project, with management support, to provide an advanced reactor multiphysics tool to assist in reactor design, optimization, and safety analysis. Much work remains in moving Griffin forward to migrate PROTEUS capabilities and to optimize performance to meet user needs. The main objective of this work is to assess the current status of Griffin capabilities in terms of performance and accuracy, to determine priorities for PROTEUS migration, and to identify capabilities and features to improve for supporting the code integration effort. For this assessment, the Empire micro reactor problem that was developed in the ARPA-E MEITNER program was selected as an advance reactor concept of interest to the technical community. The Empire reactor problem was expanded from its original incomplete specification to be a small heat-pipe-cooled micro reactor core with ~113 cm radius and 70 cm in height, composed of 18 fuel assemblies, 12 control drums, and beryllium radial and axial reflectors. In the current model, using 5 cm axial reflectors specified in the original Empire assembly model, more than 10% of neutrons leak axially and through the empty center safety hole, as well as through heat pipe channels in fuel assembly elements that extend through the top reflector region. Several calculation models of the core were defined for systematic assessment, including 2-D and 3-D fuel assemblies and whole cores with cylindrical boundaries. Cross sections were generated using Serpent 2, and meshes were produced using the Argonne mesh tool or the INL neutronics meshing tools combined with CUBIT. Cross sections and meshes were converted to the ISOXML and Exodus formats, respectively, so that Griffin and PROTEUS could use consistent data for solving the reactor problems. With the prepared cross sections and meshes, PROTEUS was run first to ensure that all input data were correctly generated and input options in terms of angle, mesh, and energy group were accurately determined. Comparisons against Serpent 2 solutions were made in terms of eigenvalue and pin power. The same calculations and comparisons were then conducted using Griffin. For the fuel assembly and whole core problems, the PROTEUS eigenvalues agreed well with reference Serpent 2 solutions within 100 and 30 pcm, respectively, and pin power differences relative to Serpent 2 were overall less than 2.2% and RMS 0.8% for the whole core models. This indicated that all input data were properly prepared. Using the same data, Griffin was run selecting the SAAF-CFEM SN solver with Legendre-Gaussian quadrature and NDA and DSA for acceleration. It was found that the SAAF-CFEM solver of Griffin required finer meshes to achieve eigenvalue and pin power solutions in good agreement with Serpent 2, consequently requiring more memory requirement and longer computation time. On the other hand, the SPH-Diffusion 2-D core calculations performed using Griffin were able to recover the exact eigenvalue from the reference Serpent 2 solutions, resulting in a pin-power distribution with an RMS of 0.6% and maximum absolute difference of less than 1.4%. The runtimes for SPH-Diffusion for the 2-D core were less than 3 minutes on 40 cores. During this evolution of this evaluation, many updates were made in Griffin by the Griffin development team of INL (focusing on software updates) and ANL (reviewing and supporting software updates) to complete this assessment. Observations from the code assessment are presented in the conclusion section of this report, followed by a discussion of recommendations for future work.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

‘Wasteaware’ benchmark indicators for integrated sustainable waste management in cities

Highlights: • Solid waste management (SWM) is a key utility service, but data is often lacking. • Measuring their SWM performance helps a city establish priorities for action. • The Wasteaware benchmark indicators: measure both technical and governance aspects. • Have been developed over 5 years and tested in more than 50 cities on 6 continents. • Enable consistent comparison between cities and countries and monitoring progress. - Abstract: This paper addresses a major problem in international solid waste management, which is twofold: a lack of data, and a lack of consistent data to allow comparison between cities. The paper presents an indicator set for integrated sustainable waste management (ISWM) in cities both North and South, to allow benchmarking of a city’s performance, comparing cities and monitoring developments over time. It builds on pioneering work for UN-Habitat’s solid waste management in the World’s cities. The comprehensive analytical framework of a city’s solid waste management system is divided into two overlapping ‘triangles’ – one comprising the three physical components, i.e. collection, recycling, and disposal, and the other comprising three governance aspects, i.e. inclusivity; financial sustainability; and sound institutions and proactive policies. The indicator set includes essential quantitative indicators as well as qualitative composite indicators. This updated and revised ‘Wasteaware’ set of ISWM benchmark indicators is the cumulative result of testing various prototypes in more than 50 cities around the world. This experience confirms the utility of indicators in allowing comprehensive performance measurement and comparison of both ‘hard’ physical components and ‘soft’ governance aspects; and in prioritising ‘next steps’ in developing a city’s solid waste management system, by identifying both local strengths that can be built on and weak points to be addressed. The Wasteaware ISWM indicators are applicable to a broad range of cities with very different levels of income and solid waste management practices. Their wide application as a standard methodology will help to fill the historical data gap.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Methodology to assess “no-touch” building audit software using simulated utility data

Building audits are conducted in many commercial buildings to identify opportunities to reduce energy costs and improve building operation. Because audits require significant effort by building engineers, they are usually only affordable for larger commercial buildings. “No-touch” building audit tools have thus been developed to identify potential savings based on a simplified analysis of building energy consumption patterns via high-level energy data such as monthly utility bills. This paper presents a comprehensive and standardized methodology to evaluate the accuracy of no-touch audit tools in detecting and diagnosing building energy problems and quantifying potential energy savings. The test suite is based on output data from a well-characterized set of building energy models, and the methodology is illustrated by applying it to a representative no-touch building audit tool. Results show that the tool estimates building energy end uses with reasonable accuracy but is less accurate in identifying probably causes of high energy.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Completing a Prototype Rocket Instrument that uses Precise Laser Measurements of Miniscule Sensor Displacements to Determine Upper Atmosphere Properties

IRAD develops and tests a laser position sensing concept to provide precise knowledge of the position of electric field spheres at the end of booms from which information of upper atmosphere properties can be determined. IRAD develops laser measurement concepts using small, inexpensive laser position sensors and building on space-based laser developments at Goddard. A prototype assembly using “paddles” has been designed to demonstrate their use on future sounding rocket and satellite missions.

Instrumentation↗

Overview of the Westinghouse Small Modular Reactor building layout

The Westinghouse Small Modular Reactor (SMR) is an 800 MWt (>225 MWe) integral pressurized water reactor (iPWR), in which all of the components typically associated with the nuclear steam supply system (NSSS) of a nuclear power plant are incorporated within a single reactor pressure vessel. This paper is the third in a series of four papers, which describe the design and functionality of the Westinghouse SMR. It focuses in particular upon the plant building layout and modular design of the Westinghouse SMR. In the development of small modular reactors, the building layout is an area where the safety of the plant can be improved by applying new design approaches. This paper will present an overview of the Westinghouse SMR building layout and indicate how the design features improve the safety and robustness of the plant. The Westinghouse SMR is designed with no shared systems between individual reactor units. The main buildings inside the security fence are the nuclear island, the rad-waste building, the annex building, and the turbine building. All safety related equipment is located in the nuclear island, which is a seismic class 1 building. To further enhance the safety and robustness of the design, the reactor, containment, and most of the safety related equipment are located below grade on the nuclear island. This reduces the possibility of severe damage from external threats or natural disasters. Two safety related ultimate heat sink (UHS) water tanks that are used for decay heat removal are located above grade, but are redundant and physically separated as far as possible for improved safety. The reactor and containment vessel are located below grade in the center of the nuclear island. The rad-waste and other radioactive systems are located on the bottom floors to limit the radiation exposure to personnel. The Westinghouse SMR safety trains are completely separated into four unconnected quadrants of the building, with access between quadrants only allowed above grade. This is an improvement to conventional reactor design since it prevents failures of multiple trains during floods or fires and other external events. The main control room is located below grade, with a remote shutdown room in a different quadrant. All defense in depth systems are placed on the nuclear island, primarily above grade, while the safety systems are located on lower floors. The economics of the Westinghouse SMR challenges the established approach of large Light Water Reactors (LWR) that utilized the economies of scale to reach economic competitiveness. To serve the market expectation of smaller capital investment and cost competitive energy, a modular design approach is implemented within the Westinghouse SMR. The Westinghouse SMR building layout integrates the three basic design constraints of modularization; transportation, handling and module-joining technology. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Smart Building Technology Training Modules for Academic and Professional Education

Smart building technologies are a new suite of resources that improve building energy efficiency and resilience, reduce carbon emissions, and provide load flexibility to the grid. However, in both college curricula and building professionals’ continuing education, there is a lack of systematic instruction on smart building technologies–topics that include smart building concepts, key components, smart building controls, “Internet of Things” (IoT) devices, and how to integrate multiple energy systems including distributed energy resources (DER). This major gap in smart building education prevents stakeholders from understanding and adopting smart building technologies in building design and operations. Slipstream leads a DOE-funded project developing a semester-long smart building curriculum for college students and adapting the contents into 16 training videos for building professionals and the general public. The education and training cover the drivers and benefits of smart building technologies, key building energy systems, the latest sensor technologies and IoT devices, and focus on topics related to smart building controls (i.e., energy management information systems, smart building control platforms, cybersecurity, grid-interactive-efficient buildings (GEBs), smart building control methods, and occupant-centric control. This paper describes the project approach, provides outlines of the training materials, and identifies lessons learned in creating the content. We also suggest ways to scale the instruction of smart building concepts to empower the workforce to accelerate the adoption of smart building technologies in the real world.

99 GENERAL AND MISCELLANEOUS↗

FRMAC Mission Analysis: What is it, and why is it useful?

In 2002, the Director of the U.S. Department of Energy's (DOE's) National Nuclear Security Administration, Division of Emergency Response, requested a team of DOE scientists, considered experts in the field of radiological consequence management, assemble and construct a mission analysis upon which the DOE could build its response program and plan for future requirements. The team developed five scenarios upon which to build the data quality objectives (DQOs) that they considered necessary to ensure a comprehensive consequence management response from the DOE perspective. The resulting document was called the Consequence Management Mission Analysis. Based upon the positive reaction to this document and its obvious benefit to the Consequence Management mission, it was decided to expand the scope of the document to cover a mission analysis of the entire Federal Radiological Monitoring and Assessment Center (FRMAC) mission. The documentation team was expanded to include representatives from all signatories to the National Response Plan who have a role in responding to radiological emergencies. The scope of the FRMAC Mission Analysis includes all federal response resources which are activated to provide rapid support to affected state and local governments in the form of radiological monitoring and dose assessment activities at the incident site. An analysis of the necessary resources was performed to determine the required numbers and types of responders, in addition to the procedures and equipment necessary for performing the monitoring and dose assessment activities from the time the federal assets arrive at the site through the first week of the incident. The five scenarios that were considered were: (1) Nuclear Detonation; (2) Nuclear Reactor Incident or Event Involving Significant Release; (3) Alpha Radiological Dispersal Devise or Failed Improvised Nuclear Device; (4) Beta-Gamma Radiological Dispersal Device; and (5) Psychological Threat.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Transforming BIM to BEM: Generation of Building Geometry for the NASA Ames Sustainability Base BIM

Typical processes of whole Building Energy simulation Model (BEM) generation are subjective, labor intensive, time intensive and error prone. Essentially, these typical processes reproduce already existing data, i.e. building models already created by the architect. Accordingly, Lawrence Berkeley National Laboratory (LBNL) developed a semi-automated process that enables reproducible conversions of Building Information Model (BIM) representations of building geometry into a format required by building energy modeling (BEM) tools. This is a generic process that may be applied to all building energy modeling tools but to date has only been used for EnergyPlus. This report describes and demonstrates each stage in the semi-automated process for building geometry using the recently constructed NASA Ames Sustainability Base throughout. This example uses ArchiCAD (Graphisoft, 2012) as the originating CAD tool and EnergyPlus as the concluding whole building energy simulation tool. It is important to note that the process is also applicable for professionals that use other CAD tools such as Revit (“Revit Architecture,” 2012) and DProfiler (Beck Technology, 2012) and can be extended to provide geometry definitions for BEM tools other than EnergyPlus. Geometry Simplification Tool (GST) was used during the NASA Ames project and was the enabling software that facilitated semi-automated data transformations. GST has now been superseded by Space Boundary Tool (SBT-1) and will be referred to as SBT-1 throughout this report. The benefits of this semi-automated process are fourfold: 1) reduce the amount of time and cost required to develop a whole building energy simulation model, 2) enable rapid generation of design alternatives, 3) improve the accuracy of BEMs and 4) result in significantly better performing buildings with significantly lower energy consumption than those created using the traditional design process, especially if the simulation model was used as a predictive benchmark during operation. Developing BIM based criteria to support the semi-automated process should result in significant reliable improvements and time savings in the development of BEMs. In order to define successful BIMS, CAD export of IFC based BIMs for BEM must adhere to a standard Model View Definition (MVD) for simulation as provided by the concept design BIM MVD (buildingSMART, 2011). In order to ensure wide scale adoption, companies would also need to develop their own material libraries to support automated activities and undertake a pilot project to improve understanding of modeling conventions and design tool features and limitations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Application of PoF Based Virtual Qualification Methods for Reliability Assessment of Mission Critical PCBs

Reliability is the ability of a product to perform the function for which it was intended for a specified period of time (or cycles) for a given set of life cycle conditions. In today's compressed mission development cycles where designing, building and testing the physical models has to occur in a matter of months not years, Projects don't have the luxury of iteratively building and testing those models. Physics of failure (PoF) is an engineering-based approach to reliability that begins with an understanding of materials, processes, physical interactions, degradation and failure mechanisms, as well as identifying failure models. The PoF approach uses modeling and simulation to qualify a design and manufacturing process, with the ultimate intent of eliminating failures early in the design process by addressing the root cause. The physics-of-failure analysis proactively incorporates reliability into the design process by establishing a scientific basis for evaluating new materials, structures and technologies. Virtual physics-of-failure modeling allows engineers to determine if new technological node can be added to an existing system. This presentation will illustrate an application of a PoF based tool during the initial phases of a printed circuit board assembly development and how the NASA GSFC team was able to dynamically study the effects of electronics parts and printed circuit board material configuration changes under simulated thermal and vibrational stresses

Electronics packaging↗

Application of PoF Based Virtual Qualification Methods for Reliability Assessment of Mission Critical PCBs

Reliability is the ability of a product to perform the function for which it was intended for a specified period of time (or cycles) for a given set of life cycle conditions. In today's compressed mission development cycles where designing, building and testing the physical models has to occur in a matter of months not years, Projects don't have the luxury of iteratively building and testing those models. Physics of failure (PoF) is an engineering-based approach to reliability that begins with an understanding of materials, processes, physical interactions, degradation and failure mechanisms, as well as identifying failure models. The PoF approach uses modeling and simulation to qualify a design and manufacturing process, with the ultimate intent of eliminating failures early in the design process by addressing the root cause. The physics-of-failure analysis proactively incorporates reliability into the design process by establishing a scientific basis for evaluating new materials, structures and technologies. Virtual physics-of-failure modeling allows engineers to determine if new technological node can be added to an existing system. This presentation will illustrate an application of a PoF based tool during the initial phases of a printed circuit board assembly development and how the NASA GSFC team was able to dynamically study the effects of electronics parts and printed circuit board material configuration changes under simulated thermal and vibrational stresses.

Physics of Failure↗

High-fidelity multiphysics load following and accidental transient modeling of microreactors using NEAMS tools: Application of NEAMS codes to perform multiphysics modeling analyses of micro-reactor concepts

The feasibility of modeling microreactors using high-fidelity models with the Nuclear Energy Advanced Modeling and Simulation (NEAMS) tools is investigated in this report. Three overarching questions guided this research: can NEAMS tools readily be applied for high-fidelity multiphysics modeling of different types of transients in microreactor designs; how accurate are the results obtained; and are improvements needed in accuracy or user experience of NEAMS tools, especially considering newly developed capabilities? This work builds upon FY-2022 work, and two microreactor concepts considering heat pipe (HP-MR) and gas-cooled (GC-MR) technologies were further analyzed using high-fidelity multiphysics simulations. The NEAMS tools considered and coupled within the MultiApp environment are Griffin for neutronics, BISON for thermo-mechanics, Sockeye for heat pipe modeling (in HP-MR), SAM for 1D Fluid – 3D solid modeling of coolant channels and system modeling of balance of plant components (in GC-MR), and the SWIFT code for hydrogen redistribution in hydride moderator. The Heat Pipe MicroReactor (HP-MR) concept was further analyzed in FY-2023 to demonstrate the stochastic TRISO failure modeling capability in BISON to check operational limits of the TRISO fuel. A new full-core Gas-Cooled MicroReactor (GC-MR) model was developed based on the initial assembly-model used in Y-2022 and used for steady-state and accidental depressurization transient simulations. Accuracy of the simulations performed was assessed through 1) verification analyses completed on the different physics with code-to-code comparison, and 2) validation of the multiphysics simulations based on modeling of the Kilopower Reactor Using Stirling Technology (KRUSTY) experiment. In FY-2023, the mesh and model of KRUSTY was updated to closely match publicly available data, and the neutronic model was verified and validated against experimental control rod worth measurements. The multiphysics model of KRUSTY was developed and used for steady-state analysis and for modeling reactivity insertion transient. The calculated power increase and stabilization agrees well with experimental data following adjustment in fuel thermal expansion coefficient. As an important component of this project, the ANL team gathered experience with a wide range of NEAMS tools: the MOOSE Mesh System, Griffin, BISON, SWIFT, Sockeye, SAM, Workbench, and the MOOSE MultiApp System, and provided assessment of new capabilities. Noteworthy are the user assessment of the “vapor-only” flow model in Sockeye and development of a multiphysics startup transient in HP-MR unit cell for use as tutorial in Sockeye. The full-core GC-MR model was used for assessment of SAM for balance of plant modeling and for demonstrating the SWIFT code capability for hydrogen redistribution modeling in multiphysics transient analyses. In this process, several bugs/issues were identified and reported to developers. Finally, the assembly GC-MR model developed in FY-2022 coupling Griffin, BISON and SAM through flow blockage and rod ejection transients was published to the National Reactor Innovation Center (NRIC) Virtual Test Bed (VTB). The Heat Pipe MicroReactor (HP-MR) concept high-fidelity multiphysics coupling of Griffin/BISON/Sockeye in load-following and heat pipe failure transients was also published on the VTB. Those submissions are enabling thorough review of these models as well as wide distribution to industry, regulator, and university users. In this analysis, several new research questions were uncovered, and follow-up analyses are recommended to further improve some models, consider additional transients, and continue development of VTB models.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Development of Fault Models for Hybrid Fault Detection and Diagnostics Algorithm: October 1, 2014 -- May 5, 2015

This report describes models of building faults created for OpenStudio to support the ongoing development of fault detection and diagnostic (FDD) algorithms at the National Renewable Energy Laboratory. Building faults are operating abnormalities that degrade building performance, such as using more energy than normal operation, failing to maintain building temperatures according to the thermostat set points, etc. Models of building faults in OpenStudio can be used to estimate fault impacts on building performance and to develop and evaluate FDD algorithms. The aim of the project is to develop fault models of typical heating, ventilating and air conditioning (HVAC) equipment in the United States, and the fault models in this report are grouped as control faults, sensor faults, packaged and split air conditioner faults, water-cooled chiller faults, and other uncategorized faults. The control fault models simulate impacts of inappropriate thermostat control schemes such as an incorrect thermostat set point in unoccupied hours and manual changes of thermostat set point due to extreme outside temperature. Sensor fault models focus on the modeling of sensor biases including economizer relative humidity sensor bias, supply air temperature sensor bias, and water circuit temperature sensor bias. Packaged and split air conditioner fault models simulate refrigerant undercharging, condenser fouling, condenser fan motor efficiency degradation, non-condensable entrainment in refrigerant, and liquid line restriction. Other fault models that are uncategorized include duct fouling, excessive infiltration into the building, and blower and pump motor degradation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Affordable Cold Climate Infill Housing with Hybrid Insulation Approach, Wyandotte, Michigan (Fact Sheet)

Even builders who are relatively new to energy-efficient construction can consistently reach a target whole house airtightness of 1.5 air changes per hour at 50 Pascals (ACH50) with high R-value enclosures that use a hybrid insulation approach. The City of Wyandotte, Michigan, started a construction program in 2010 to build affordable, energy-efficient homes on lots in existing neighborhoods. A goal of the program was to engage local builders in energy-efficient construction and be able to deliver the new houses for less than $100/ft2. By the end of 2012, approximately 25 new houses were built by five local builders under this program. To help builders consistently achieve the airtightness target, a local architect worked with researchers from Building Science Corporation, a U.S. Department of Energy Building America team, to develop a technology specification with several key pieces. A high R-value wall and roof assembly made use of 2 ?6 advanced framing and a hybrid insulation approach that included insulating sheathing to control thermal bridging and closed cell spray polyurethane foam insulation (ccSPF) for its airtightness and vapor control benefits. This approach allows the air barrier to be completed and tested before any finishing work occurs, ensuring that problems are spotted and corrected early in the construction process.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Development and thermal performance verification of composite insulation boards containing foam-encapsulated vacuum insulation panels

High-performance thermal insulation is a critical need for buildings. This article presents the development and thermal characterization of composite foam insulation boards containing low-cost vacuum insulation cores. The composite foam-vacuum insulation boards were created in a semi-automatic operation in a foam insulation manufacturing plant. The low-cost vacuum insulation is a new technology called modified atmosphere insulation. The production process of modified atmosphere insulation is much simpler than traditional vacuum insulation manufacturing, and it has the potential for significant cost reduction at the same thermal performance. Prototypes of small- and full-scale composite insulation boards were created for testing and evaluation under laboratory and natural weatherization conditions. The laboratory tests showed that the overall thermal resistance of the composite insulation board is at least twice that of current rigid foam insulation used in building envelope. Lastly, ongoing test of the composite insulation in a natural exposure test facility indicates that the high thermal performance was retained through handling and installation as well as natural aging over a period of one and a half years.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

DOE Zero Energy Ready Home Case Study: Amaris Custom Homes, St. Paul, Minnesota

For this project, Amaris worked with U.S. Department of Energy (DOE) team, NorthernSTAR Building America Partnership, to develop the first Zero Energy Ready Home (ZERH) in Minnesota's cold climate using reasonable, cost-effective, and replicable construction materials and practices. The result is a passive solar, super-efficient 3542-ft2 walkout ranch-style home with all the creature comforts. Along with meeting ZERH standards, Amaris also achieved certifications for Leadership in Energy & Environmental Design for Homes v4, MN Green Path Emerald, and a Builders Association of the Twin Cities Reggie Award of Excellence. The home achieves a HERS score of 41 without photovoltaics; with PV, the home achieves a HERS score of 5.

Building America↗

Assessment of urban aerosol pollution over the Moscow megacity by the MAIAC aerosol product

We estimated the distribution of aerosol optical thickness (AOT) with a spatial resolution of 1 km over the Moscow megacity using the MAIAC aerosol product based on MODIS satellite data (Lyapustin et al., 2018) for the warm period of the year (May–September, 2001–2017). AERONET (Aerosol Robotic Network)-based validation of satellite estimates near the city centre at Moscow_MSU_MO and over the Moscow suburbs at Zvenigorod revealed that MAIAC AOT at 0.47 μm is in agreement with AERONET AOT though underestimated by 0.05–0.1 for AOT < 1 and overestimated for smoke conditions with AOT > 1. The MAIAC AOT biases were almost the same for the Moscow_MSU_MO and Zvenigorod AERONET sites, which indicated that the MAIAC algorithm effectively removed the effect of the bright urban surface in the city centre. For the ground-based measurements, the difference between annual median AOT at Moscow_MO_MSU and Zvenigorod (∆AOT) varied within -0:002 to +0:03, with statistically significant positive bias for most years, and an average ∆AOT was about 0.02. According to the MAIAC dataset, the ∆AOT varied within ±0:01 and was not statistically significant. The ∆AOT started decreasing recently due to intensive urban development of the territory around Zvenigorod and the decrease in pollutant emissions in Moscow, which is mainly caused by the environmental regulations. According to the MAIAC dataset, the most pronounced spatial AOT differences over the territory of Moscow were observed at the 5% quantile level, where they reached 0.05–0.06 over several locations and could be attributed to the stationary sources of aerosol pollution, for example, large areas of construction sites, aerosol pollution from roads and highways, or agriculture activities. The differences between the maximum and the mean AOT for different quantiles, except the 95% quantile, within the Moscow region, were about 0.02–0.04, which could be attributed to the local aerosol sources. The application of the MAIAC algorithm over the whole Moscow region has revealed a decreasing AOT trend over the centre of Moscow and an increasing trend over the “New” Moscow territory which experienced an intensive build-up and agricultural development.