Search NASA⌕ Search

SEARCH · Search NASA

Results for “data reconstruction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,189 records · Page 66

Search for pair-produced three-jet resonances in proton-proton collisions at s = 13 TeV

Here, a search has been performed for pair-produced resonances decaying into three jets. The proton-proton collision data used for this analysis were collected with the CMS detector in 2016 at a center-of-mass energy of 13 TeV and correspond to an integrated luminosity of 35.9 fb$^{-1}$. The mass range from 200 to 2000 GeV is explored in four separate mass regions. The observations show agreement with standard model expectations. The results are interpreted within the framework of $R$-parity violating SUSY, where pair-produced gluinos decay to a six quark final state. Gluino masses below 1500 GeV are excluded at 95% confidence level. An analysis based on data with multijet events reconstructed at the trigger level extends the reach to masses as low as 200 GeV. Improved analysis techniques have led to enhanced sensitivity, allowing the most stringent limits to date to be set on gluino pair production.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Suppression of Decoherence in Fast-Atom Diffraction at Surfaces

Scattering of fast neutral atoms with keV kinetic energies at alkali-halide surfaces under grazing angles displays intriguing diffraction patterns. The surprisingly strong persistence of quantum coherence despite the impulsive interaction with an environment at solid state density and elevated temperatures raises fundamental questions such as to the suppression of decoherence and of the quantum-to-classical crossover. We present an ab initio simulation of the quantum diffraction of fast helium beams at a LiF (100) surface in the <110> direction and compare with recent experimental diffraction data. From the quantitative reconstruction of diffraction images the vertical LiF-surface reconstruction, or buckling, can be determined.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Strategies for high-throughput focused-beam ptychography

X-ray ptychography is being utilized for a wide range of imaging experiments with a resolution beyond the limit of the X-ray optics used. Introducing a parameter for the ptychographic resolution gain G p (the ratio of the beam size over the achieved pixel size in the reconstructed image), strategies for data sampling and for increasing imaging throughput when the specimen is at the focus of an X-ray beam are considered. As a result, the tradeoffs between large and small illumination spots are examined.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Plug-and-Play Methods for Integrating Physical and Learned Models in Computational Imaging: Theory, algorithms, and applications

Plug-and-play (PnP) priors constitute one of the most widely used frameworks for solving computational imaging problems through the integration of physical models and learned models. PnP leverages high-fidelity physical sensor models and powerful machine learning methods for prior modeling of data to provide state-of-the-art reconstruction algorithms. PnP algorithms alternate between minimizing a data fidelity term to promote data consistency and imposing a learned regularizer in the form of an image denoiser. Recent highly successful applications of PnP algorithms include biomicroscopy, computerized tomography (CT), magnetic resonance imaging (MRI), and joint ptychotomography. This article presents a unified and principled review of PnP by tracing its roots, describing its major variations, summarizing main results, and discussing applications in computational imaging. Additionally, we also point the way toward further developments by discussing recent results on equilibrium equations that formulate the problem associated with PnP algorithms.

97 MATHEMATICS AND COMPUTING↗

TU-A-12A-08: Computing Longitudinal Material Changes in Bone Metastases Using Dual Energy Computed Tomography

Purpose: This study demonstrates a methodology for tracking changes in metastatic bone disease using trajectories in material basis space in serial dual energy computed tomography (DECT) studies. Methods: This study includes patients with bone metastases from breast cancer that had clinical surveillance CT scans using a General Electric CT750HD in dual energy mode. A radiologist defined regions-of-interested (ROI) for bone metastasis, normal bone, and marrow across the serial DECT scans. Our approach employs a Radon transform to forward-projection the basis images, namely, water and iodine, into sinogram space. This data is then repartitioned into fat/bone and effective density/Z image pairs using assumed energy spectrums for the x-ray energies. This approach both helps remove negative material densities and avoids adding spectrum-hardening artifacts. These new basis data sets were then reconstructed via filtered back-projection to create new material basis pair images. The trajectories of these pairs were then plotted in the new basis space providing a means to both visualize and quantitatively measure changes in the material properties of the tumors. Results: ROI containing radiologist defined metastatic bone disease showed well-defined trajectories in both fat/bone and effective density/Z space. ROI that contained radiologist defined normal bone and marrow did not exhibit any discernible trajectories and were stable from scan to scan. Conclusions: The preliminary results show that changes in material composition and effective density/Z image pairs were seen primarily in metastasis and not in normal tissue. This study indicates that by using routine clinical DECT it may be possible to monitor therapy response of bone metastases because healing or worsening bone metastases change material composition of bone. Additional studies are needed to further validate these results and to test for their correlation with outcome.

60 APPLIED LIFE SCIENCES↗

TU-AB-207-00: Digital Tomosynthesis

Digital Tomosynthesis (DT) is becoming increasingly common in breast imaging and many other applications. DT is a form of computed tomography in which a limited set of projection images are acquired over a small angular range and reconstructed into a tomographic data set. The angular range and number of projections is determined both by the imaging task and equipment manufacturer. For example, in breast imaging between 9 and 25 projections are acquired over a range of 15° to 60°. It is equally valid to treat DT as the digital analog of classical tomography - for example, linear tomography. In fact, the name “tomosynthesis” is an acronym for “synthetic tomography”. DT shares many common features with classical tomography, including the radiographic appearance, dose, and image quality considerations. As such, both the science and practical physics of DT systems is a hybrid between CT and classical tomographic methods. This lecture will consist of three presentations that will provide a complete overview of DT, including a review of the fundamentals of DT, a discussion of testing methods for DT systems, and a description of the clinical applications of DT. While digital breast tomosynthesis will be emphasized, analogies will be drawn to body imaging to illustrate and compare tomosynthesis methods. Learning Objectives: To understand the fundamental principles behind tomosynthesis, including the determinants of image quality and dose. To learn how to test the performance of tomosynthesis imaging systems. To appreciate the uses of tomosynthesis in the clinic and the future applications of tomosynthesis.

60 APPLIED LIFE SCIENCES↗

TU-AB-207-01: Introduction to Tomosynthesis

Digital Tomosynthesis (DT) is becoming increasingly common in breast imaging and many other applications. DT is a form of computed tomography in which a limited set of projection images are acquired over a small angular range and reconstructed into a tomographic data set. The angular range and number of projections is determined both by the imaging task and equipment manufacturer. For example, in breast imaging between 9 and 25 projections are acquired over a range of 15° to 60°. It is equally valid to treat DT as the digital analog of classical tomography - for example, linear tomography. In fact, the name “tomosynthesis” is an acronym for “synthetic tomography”. DT shares many common features with classical tomography, including the radiographic appearance, dose, and image quality considerations. As such, both the science and practical physics of DT systems is a hybrid between CT and classical tomographic methods. This lecture will consist of three presentations that will provide a complete overview of DT, including a review of the fundamentals of DT, a discussion of testing methods for DT systems, and a description of the clinical applications of DT. While digital breast tomosynthesis will be emphasized, analogies will be drawn to body imaging to illustrate and compare tomosynthesis methods. Learning Objectives: To understand the fundamental principles behind tomosynthesis, including the determinants of image quality and dose. To learn how to test the performance of tomosynthesis imaging systems. To appreciate the uses of tomosynthesis in the clinic and the future applications of tomosynthesis.

60 APPLIED LIFE SCIENCES↗

TU-AB-207-02: Testing of Body and Breast Tomosynthesis Sytems

Digital Tomosynthesis (DT) is becoming increasingly common in breast imaging and many other applications. DT is a form of computed tomography in which a limited set of projection images are acquired over a small angular range and reconstructed into a tomographic data set. The angular range and number of projections is determined both by the imaging task and equipment manufacturer. For example, in breast imaging between 9 and 25 projections are acquired over a range of 15° to 60°. It is equally valid to treat DT as the digital analog of classical tomography - for example, linear tomography. In fact, the name “tomosynthesis” is an acronym for “synthetic tomography”. DT shares many common features with classical tomography, including the radiographic appearance, dose, and image quality considerations. As such, both the science and practical physics of DT systems is a hybrid between CT and classical tomographic methods. This lecture will consist of three presentations that will provide a complete overview of DT, including a review of the fundamentals of DT, a discussion of testing methods for DT systems, and a description of the clinical applications of DT. While digital breast tomosynthesis will be emphasized, analogies will be drawn to body imaging to illustrate and compare tomosynthesis methods. Learning Objectives: To understand the fundamental principles behind tomosynthesis, including the determinants of image quality and dose. To learn how to test the performance of tomosynthesis imaging systems. To appreciate the uses of tomosynthesis in the clinic and the future applications of tomosynthesis.

60 APPLIED LIFE SCIENCES↗

TU-AB-207-03: Tomosynthesis: Clinical Applications

Digital Tomosynthesis (DT) is becoming increasingly common in breast imaging and many other applications. DT is a form of computed tomography in which a limited set of projection images are acquired over a small angular range and reconstructed into a tomographic data set. The angular range and number of projections is determined both by the imaging task and equipment manufacturer. For example, in breast imaging between 9 and 25 projections are acquired over a range of 15° to 60°. It is equally valid to treat DT as the digital analog of classical tomography - for example, linear tomography. In fact, the name “tomosynthesis” is an acronym for “synthetic tomography”. DT shares many common features with classical tomography, including the radiographic appearance, dose, and image quality considerations. As such, both the science and practical physics of DT systems is a hybrid between CT and classical tomographic methods. This lecture will consist of three presentations that will provide a complete overview of DT, including a review of the fundamentals of DT, a discussion of testing methods for DT systems, and a description of the clinical applications of DT. While digital breast tomosynthesis will be emphasized, analogies will be drawn to body imaging to illustrate and compare tomosynthesis methods. Learning Objectives: To understand the fundamental principles behind tomosynthesis, including the determinants of image quality and dose. To learn how to test the performance of tomosynthesis imaging systems. To appreciate the uses of tomosynthesis in the clinic and the future applications of tomosynthesis.

60 APPLIED LIFE SCIENCES↗

High resolution functional photoacoustic tomography of breast cancer

Purpose: To evaluate the feasibility of functional photoacoustic tomography (fPAT) for high resolution detection and characterization of breast cancer and to demonstrate for the first time quantitative hemoglobin concentration and oxygen saturation images of breasts that were formed with model-based reconstruction of tomographic photoacoustic data. Methods: The study was HIPAA compliant and was approved by the university institutional review board. Written informed consents were obtained from all the participants. Ten cases, including six cancer and four healthy (mean age = 50 yr; age range = 41–66 yr), were examined. Functional images of breast tissue including absolute total hemoglobin concentration (Hb{sub T}) and oxygen saturation (StO{sub 2}%) were obtained by fPAT and cross validated with magnetic resonance imaging (MRI) readings and/or histopathology. Results: Hb{sub T} and StO{sub 2}% maps from all six pathology-confirmed cancer cases (60%) show clear detection of tumor, while MR images indicate clear detection of tumor for five of six cancer cases; one small tumor was read as near-complete-resolution by MRI. The average Hb{sub T} and StO{sub 2}% value of suspicious lesion area for the cancer cases was 61.6 ± 18.9 μM/l and 67.5% ± 5.2% compared to 25.6 ± 7.4 μM/l and 65.2% ± 3.8% for background normal tissue. Conclusions: fPAT has the potential to be a significant add-on in breast cancer detection and characterization as it provides submillimeter resolution functional images of breast lesions.

60 APPLIED LIFE SCIENCES↗

Using ancient protein kinases to unravel a modern cancer drug’s mechanism

Evolution of dynamics affects function The drug Gleevac inhibits Abl kinases and is used to treat multiple cancers. The closely related Src kinases also play a role in cancer but are not inhibited effectively by Gleevac. Nevertheless, Gleevac-bound structures of Src and Abl are nearly identical. Based on this structural information and protein sequence data, Wilson et al. reconstructed the common ancestor of Src and Abl. Mutations that affected conformational dynamics caused Gleevac affinity to be gained on the evolutionary trajectory toward Abl and lost on the trajectory toward Src. Science , this issue p. 882

59 BASIC BIOLOGICAL SCIENCES↗

Redox stratification of an ancient lake in Gale crater, Mars

In 2012, NASA’s Curiosity rover landed on Mars to assess its potential as a habitat for past life and investigate the paleoclimate record preserved by sedimentary rocks inside the ~150-kilometer-diameter Gale impact crater. Geological reconstructions from Curiosity rover data have revealed an ancient, habitable lake environment fed by rivers draining into the crater. We synthesize geochemical and mineralogical data from lake-bed mudstones collected during the first 1300 martian solar days of rover operations in Gale. We present evidence for lake redox stratification, established by depth-dependent variations in atmospheric oxidant and dissolved-solute concentrations. Paleoclimate proxy data indicate that a transition from colder to warmer climate conditions is preserved in the stratigraphy. Lastly, a late phase of geochemical modification by saline fluids is recognized.

58 GEOSCIENCES↗

Detection of reflected Cherenkov light from extensive air showers in the SPHERE experiment as a method of studying superhigh energy cosmic rays

Although a large number of experiments were carried out during the last few decades, the uncertainty in the spectrum of all nuclei of primary cosmic rays (PCRs) with superhigh energies is still high, and the results of many experiments on nuclear composition of PCRs are contradictory. An overview of the SPHERE experiment on detecting Vavilov-Cherenkov radiation from extensive air shower (EAS) reflected from a ground snow surface is given. A number of experimental studies implementing this method are presented and their results are analyzed. Some other popular methods of studying PCRs with superhigh energies (E{sub 0} > 10{sup 15} eV) and their main advantages and drawbacks are briefly considered. The detecting equipment of the SPHERE-2 experiment and the technique of its calibration are considered. The optical properties of snow, which are important for experiments on reflected Cherenkov light (CL) from EAS, are discussed and the history of observing reflected EAS CL is described. The algorithm of simulating the detector response and calculating the fiducial acceptance of shower detection is described. The procedure of processing the experimental data with a subsequent reconstruction of the spectrum of all PCR nuclei and analysis of the mass composition is shown. The first results of reconstructing the spectrum and separating groups of cosmic-ray nuclei with high energies in the SPHERE-2 experiment are presented. Main sources of systematic errors are considered. The prospects of developing the technique of observation of reflected EAS CL in future experiments are discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Energy spectrum and transport in narrow HgTe quantum wells

The results of an experimental study of the transport phenomena and the hole energy spectrum of two-dimensional systems in the quantum well of HgTe zero-gap semiconductor with normal arrangement of quantum-confinement subbands are presented. An analysis of the experimental data allows us to reconstruct the carrier energy spectrum near the hole subband extrema. The results are interpreted using the standard kP model.

36 MATERIALS SCIENCE↗

Measurements of the $\mathrm{Z}$ $\mathrm{Z}$ production cross sections in the $2\mathrm{l} 2\nu $ channel in proton–proton collisions at $\sqrt{s} = 7$ and $8~\mathrm{TeV} $ and combined constraints on triple gauge couplings

Measurements of the $\mathrm{Z}$ $\mathrm{Z}$ production cross sections in proton–proton collisions at center-of-mass energies of 7 and 8 $~\mathrm{TeV}$ are presented. Candidate events for the leptonic decay mode $\mathrm{Z}\mathrm{Z}\rightarrow 2\mathrm{l} 2\nu $ , where $\mathrm{l}$ denotes an electron or a muon, are reconstructed and selected from data corresponding to an integrated luminosity of 5.1 (19.6) $\,\text {fb}^\text {-1}$ at 7 (8) $~\mathrm{TeV}$ collected with the CMS experiment. The measured cross sections, $\sigma (\mathrm {p}\mathrm {p}\rightarrow \mathrm{Z}\mathrm{Z}) = 5.1_{-1.4}^{+1.5}\,\text {(stat)} \,_{-1.1}^{+1.4}\,\text {(syst)} \pm 0.1\,\text {(lumi)} \text {~pb} $ at 7 $~\mathrm{TeV}$ , and $7.2_{-0.8}^{+0.8}\,\text {(stat)} \,_{-1.5}^{+1.9}\,\text {(syst)} \,\pm \, 0.2\,\text {(lumi)} \text {~pb} $ at 8 $~\mathrm{TeV}$ , are in good agreement with the standard model predictions with next-to-leading-order accuracy. The selected data are analyzed to search for anomalous triple gauge couplings involving the $\mathrm{Z}$ $\mathrm{Z}$ final state. In the absence of any deviation from the standard model predictions, limits are set on the relevant parameters. These limits are then combined with the previously published CMS results for $\mathrm{Z}$ $\mathrm{Z}$ in 4 $\mathrm{l}$ final states, yielding the most stringent constraints on the anomalous couplings.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Operation and performance of the ATLAS tile calorimeter in LHC Run 2

The ATLAS tile calorimeter (TileCal) is the hadronic sampling calorimeter covering the central region of the ATLAS detector at the Large Hadron Collider (LHC). This paper gives an overview of the calorimeter’s operation and performance during the years 2015–2018 (Run 2). In this period, ATLAS collected proton–proton collision data at a centre-of-mass energy of 13 TeV and the TileCal was 99.65% efficient for data-taking. The signal reconstruction, the calibration procedures, and the detector operational status are presented. The performance of two ATLAS trigger systems making use of TileCal information, the minimum-bias trigger scintillators and the tile muon trigger, is discussed. Studies of radiation effects allow the degradation of the output signals at the end of the LHC and HL-LHC operations to be estimated. Finally, the TileCal response to isolated muons, hadrons and jets from proton–proton collisions is presented. The energy and time calibration methods performed excellently, resulting in good stability and uniformity of the calorimeter response during Run 2. The setting of the energy scale was performed with an uncertainty of 2%. The results demonstrate that the performance is in accordance with specifications defined in the Technical Design Report.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

als microct recon (microct) v1

Jupyter notebooks to reconstruct and visualize microCT data from ALS beamline 8.3.2. Relies on standard tomography and image processing tools (astra, tomopy, itk, scikit-image) and ipywidgets (sliders, drop down menus, etc) to make parameter selection and data visualization easy for users.

Parkinson, Dilworth↗