Search NASA⌕ Search

SEARCH · Search NASA

Results for “depth profiling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,189 records · Page 66

The “accumulation effect” of positrons in the stack of foils, detected by measurements of the positron implantation profile

The profiles of positrons implanted from the radioactive source {sup 22}Na into a stack of foils and plates are the subject of our experimental and theoretical studies. The measurements were performed using the depth scanning of positron implantation profile method, and the theoretical calculations using the phenomenological multi-scattering model (MSM). Several stacks consisting of silver, gold and aluminum foils, and titanium and germanium plates were investigated. We notice that the MSM describes well the experimental profiles; however when the stack consisting of silver and gold foils, the backscattering and linear absorption coefficients differ significantly from those reported in the literature. We suggest the energy dependency of the backscattering coefficient for silver and gold. In the stacks which comprise titanium and germanium plates, there were observed the features, which indicate the presence of the “accumulation effect” in the experimental implantation profile. This effect was previously detected in implantation profiles in Monte Carlo simulations using the GEANT4 tool kit, and it consists in higher localization of positrons close the interface. We suppose that this effect can be essential for positron annihilation in any heterogeneous materials.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

SOLAR MODELS WITH NEW LOW METAL ABUNDANCES

In the past decade, the photospheric abundances of the Sun had been revised several times by many observers. The standard solar models constructed with the new low-metal abundances disagree with helioseismic results and detected neutrino fluxes. The solar model problem has puzzled some stellar physicists for more than 10 years. Rotation, enhanced diffusion, convection overshoot, and magnetic fields are used to reconcile the new abundances with helioseismology. The too low helium subsurface abundance in enhanced diffusion models can be improved by the mixing caused by rotation and magnetic fields. The problem of the depth of the convective zone in rotating models can be resolved by convection overshoot. Consequently, the Asplund–Grevesse–Sauval rotation model including overshooting (AGSR) reproduces the seismically inferred sound-speed and density profiles and the convection zone depth as well as the Grevesse and Sauval model computed before. But this model fails to reproduce the surface helium abundance, which is 0.2393 (2.6 σ away from the seismic value), and neutrino fluxes. The magnetic model called AGSM keeps the agreement of the AGSR and improves the prediction of the surface helium abundance. The observed separation ratios r {sub 02} and r {sub 13} are reasonably reproduced by AGSM. Moreover, neutrino fluxes calculated by this model are not far from the detected neutrino fluxes and the predictions of previous works.

79 ASTRONOMY AND ASTROPHYSICS↗

Characterizing Intracluster Light in the Hubble Frontier Fields

We investigate the intracluster light (ICL) in the six Hubble Frontier Field clusters at 0.3<z<0.6. We employ a new method, which is free from any functional form of the ICL profile, and exploit the unprecedented depth of this Hubble Space Telescope imaging to map the ICL’s diffuse light out to clustrocentric radii R∼300 kpc (μ{sub ICL}∼27 mag arcsec{sup −2}). From these maps, we construct radial color and stellar mass profiles via SED fitting and find clear negative color gradients in all systems with increasing distance from the Brightest Cluster Galaxy (BCG). While this implies older/more metal-rich stellar components in the inner part of the ICL, we find that the ICL mostly consists of a ≲2 Gyr population, and plausibly originated with logM{sub ∗}/M{sub ⊙}≲10 cluster galaxies. Furthermore, we find that 10%–15% of the ICL’s mass at large radii (≳150 kpc) lies in a younger/bluer stellar population (∼1 Gyr), a phenomenon not seen in local samples. We attribute this light to the higher fraction of star-forming/(post-)starburst galaxies in clusters at z∼0.5. Ultimately, we find the ICL’s total mass to be logM{sub ∗}{sup ICL}/M{sub ⊙}∼11–12, constituting 5%–20% of the clusters’ total stellar mass, or about half of the value at z∼0. The above implies distinct formation histories for the ICL and BCGs/other massive cluster galaxies; i.e., the ICL at this epoch is still being constructed rapidly (∼40 M{sub ⊙} yr{sup −1}), while the BCGs have mostly completed their evolution. To be consistent with the ICL measurements of local massive clusters, such as Virgo, our data suggest mass acquisition mainly from quiescent cluster galaxies is the principal source of ICL material in the subsequent ∼5 Gyr of cosmic time.

79 ASTRONOMY AND ASTROPHYSICS↗

SU-E-T-561: Development of Depth Dose Measurement Technique Using the Multilayer Ionization Chamber for Spot Scanning Method

Purpose: To develop a measurement technique which suppresses the difference between profiles obtained with a multilayer ionization chamber (MLIC) and with a water phantom. Methods: The developed technique multiplies the raw MLIC data by a correction factor that depends on the initial beam range and water equivalent depth. The correction factor is derived based on a Bragg curve calculation formula considering range straggling and fluence loss caused by nuclear reactions. Furthermore, the correction factor is adjusted based on several integrated depth doses measured with a water phantom and the MLIC. The measured depth dose profiles along the central axis of the proton field with a nominal field size of 10 by 10 cm were compared between the MLIC using the new technique and the water phantom. The spread out Bragg peak was 20 cm for fields with a range of 30.6 cm and 6.9 cm. Raw MLIC data were obtained with each energy layer, and integrated after multiplying by the correction factor. The measurements were performed by a spot scanning nozzle at Nagoya Proton Therapy Center, Japan. Results: The profile measured with the MLIC using the new technique is consistent with that of the water phantom. Moreover, 97% of the points passed the 1% dose /1mm distance agreement criterion of the gamma index. Conclusion: We have demonstrated that the new technique suppresses the difference between profiles obtained with the MLIC and with the water phantom. It was concluded that this technique is useful for depth dose measurement in proton spot scanning method.

07 ISOTOPE AND RADIATION SOURCES↗

SU-E-T-406: Evaluation of the Stealth Chamber by IBA Under Large Field Conditions

Purpose: To evaluate the performance of the stealth chamber by IBA under large field conditions. Methods: Measurement of PDDs and profiles for fields of 10×10, 15×15, 20×20 and 25×25 cm2 were acquired in a blue phantom2 scanning system for 6 and 15 MV beams in a Varian TrueBeam linear accelerator. The stealth chamber has a field size limit of 25×25 cm2. Measurements with two different detector set were performed. First a cc13 chamber as field and reference chamber was acquired. And with a cc13 chamber as field detector and the stealth chamber as the reference chamber. PDDs for the fields mentioned above were conducted and profiles with the same fields at depth of dmax, 5, 10 and 20 cm were acquired for comparison. Results: Examination of the PDDs and profile comparison with a criterion of 1% and 1 mm agreement was performed. Very good agreement between the cc13 and stealth chamber set was observed within the chosen criterion. Conclusion: This work indicates the comparable results obtained with the use of the stealth chamber and cc13 as the reference chamber in relative dosimetry measurements.

43 PARTICLE ACCELERATORS↗

Robust surfactant-assisted one-pot sample preparation for label-free single-cell and nanoscale proteomics

With advanced mass spectrometry (MS)-based proteomics, genome-scale proteome coverage can be achieved from bulk cells. However, such bulk measurement obscures cell to cell heterogeneity, precluding proteome profiling of single cells and small numbers of cells of interest. To address this issue, in recent 5 years there are a surge of small sample preparation methods developed for robust effective collection and processing of single cells and small numbers of cells for in-depth MS-based proteome profiling. Based on their broad accessibility, they can be categorized into two types: specific device- and standard PCR tube- or multi-well plate-based methods. Herein we describe the detailed protocol of our recently developed, easily adoptable, Surfactant-assisted One-Pot (SOP) sample preparation coupled with MS method termed SOP-MS for label-free single-cell and nanoscale proteomics. SOP-MS capitalizes on the combination of a MS-compatible surfactant, DDM (n-Dodecyl-ß-D-maltoside), and standard low-bind PCR tube or multi-well plate for ‘all-in-one’ one-pot sample preparation without sample transfer. With its robust and convenient features, SOP-MS can be readily implemented in any MS laboratory for single-cell and nanoscale proteomics. With further improvements in MS detection sensitivity and sample throughput, we believe that SOP-MS could open an avenue for single-cell proteomics with broad applicability in the biological and biomedical research.

Single-cell proteomics, nanoscale proteomics, SOP-↗

Improvements in Monte Carlo Simulation of Large Electron Fields

Two Monte Carlo systems, EGSnrc and Geant4, were used to calculate dose distributions in large electron fields used in radiotherapy. Source and geometry parameters were adjusted to match calculated results with measurement. Both codes were capable of accurately reproducing the measured dose distributions of the 6 electron beams available on the accelerator. Depth penetration was matched to 0.1 cm. Depth dose curves generally agreed to 2% in the build-up region, although there is an additional 2-3% experimental uncertainty in this region. Dose profiles matched to 2% at the depth of maximum dose in the central region of the beam, out to the point of the profile where the dose begins to fall rapidly. A 3%/3mm match was obtained outside the central region except for the 6 MeV beam, where dose differences reached 5%. The discrepancy observed in the bremsstrahlung tail in published results that used EGS4 is no longer evident. The different systems required different source energies, incident beam angles, thicknesses of the exit window and primary foils, and distance between the primary and secondary foil. These results underscore the requirement for an experimental benchmark of electron scatter for beam energies and foils relevant to radiotherapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Advancing Tunnel Detection Via Vertical Acoustic Profiling

This study demonstrates that placing an acoustic source at depth significantly enhances the detection of tunnels. By adapting the methodology of vertical seismic profiling to acoustic-range frequencies, we introduce a novel approach for tunnel detection. To our knowledge, this report documents the first application of this technique. The field study was conducted on a cleared site at the Oak Ridge National Laboratory; the subsurface was clay. A series of vertical shafts were bored immediately before and after the placement of a 40 ft long, 3 ft diameter steel pipe located 10 ft below the surface. Acoustic signatures were produced at various depths up to 30 ft and an array of surface geophones was used to collect the resulting signals. The innovation lies in using subsurface acoustic signatures to better enable the collection of wide-angle diffracted waves by surface geophones. These diffracted waves appear as subharmonic frequencies of the source signal and are recorded by a surface geophone array. While the concept draws from vertical seismic profiling used in oil and gas exploration, a key distinguishing feature is the use of acoustic frequencies, which are necessary for detecting small subsurface features. The findings have important implications. Critical information pertaining to diffracted source signals are not measured by current state-of-the-art methods. Although this study confirms enhanced detectability, accurate localization and imaging will require additional research. Future work should focus on leveraging diffracted-wave strength and time delays to enable full imaging and characterization.

47 OTHER INSTRUMENTATION↗

Benzene polycarboxylic acids, lignin and hydrolysable lipids data from the whole-soil warming experiment at Blodgett Forest, CA, 2018, from: "Rapid loss of complex polymers and pyrogenic carbon in subsoils under whole soil warming"

This data package contains benzene polycarboxylic acids, lignin and hydrolysable lipids data used for the paper: “Rapid loss of subsoil plant-derived polymers and pyrogenic carbon with whole-soil warming”.On April 2018 (after 4.5 years of warming), we collected soil cores down to 90 cm depth from the whole soil profile warming experiment at the University of California Blodgett Forest Research Station, in the Sierra Nevada foothills near Georgetown, CA at 1370 m above sea level. Cores were collected from 6 experimental plots (three replicated blocks); samples were collected in 10 cm increments from 0 to 90 cm depth. This data package includes a file in .csv format and a file in .xlsx format, which can be accessed and processed using MS Excel or R. Benzene polycarboxylic acid, lignin and hydrolysable lipid concentrations are provided as processed data files.The aim of the measurements was to assess how +4°C of whole-soil warming for 4.5 years will affect structurally complex polymeric compounds at different soil depths. The research was supported by Swiss National Science Foundation (SNF) project 172744 (DEEP C) and U.S. Department of Energy, Office of Science, Office of Biological and Environmental Research under contract number DE-AC02-05CH11231.

54 ENVIRONMENTAL SCIENCES↗

Estimation of bare soil evaporation for different depths of water table in the wind-blown sand area of the Ordos Basin, China

Soil surface evaporation is a significant component of the hydrological cycle, occurring at the interface between the atmosphere and vadose zone, but it is affected by factors such as groundwater level, soil properties, solar radiation and others. In order to understand the soil evaporation characteristics in arid regions, a field experiment was conducted in the Ordos Basin, central China, and high accuracy sensors of soil moisture, moisture potential and temperature were installed in three field soil profiles with water-table depths (WTDs) of about 0.4, 1.4 and 2.2 m. Soil-surface-evaporation values were estimated by observed data combined with Darcy’s law. Results showed that: (1) soil-surface-evaporation rate is linked to moisture content and it is also affected by air temperature. When there is sufficient moisture in the soil profile, soil evaporation increases with rising air temperature. For a WTD larger than the height of capillary rise, the soil evaporation is related to soil moisture content, and when air temperature is above 25 °C, the soil moisture content reduces quickly and the evaporation rate lowers; (2) phreatic water contributes to soil surface evaporation under conditions in which the WTD is within the capillary fringe. This indicates that phreatic water would not participate in soil evaporation for a WTD larger than the height of capillary rise. This finding developed further the understanding of phreatic evaporation, and this study provides valuable information on recognized soil evaporation processes in the arid environment.

58 GEOSCIENCES↗

Ruthenium nano-oxide layer in CoFe-Ru-CoFe trilayer system: An x-ray reflectivity study

A grazing incidence x-ray reflectivity technique is used to determine the electron density profile as a function of depth in CoFe-Ru-CoFe and CoFe-Ru nano-oxide layer (NOL)-CoFe trilayers. Four trilayers with ruthenium thicknesses of 8, 8.5, and 9 A and one with Ru 8.5 A NOL, prepared by a dc planetary sputtering system, were investigated. For all samples, the electron density profile (EDP) shows a central peak that is related to the Ru layer. Natural oxidation in all of the samples introduces a graded EDP of the top CoFe layers, which decreases gradually to zero. The large surface resistivity of Ru 8.5 A NOL as compared to Ru 8.5 A is related to the remarkable difference between their EDPs. EDP changes have also been investigated in Ru NOL trilayers after annealing at 280 deg. C. The Ru phase in the EDP was observed to confirm the thermal stability of the spacer layer after annealing.

36 MATERIALS SCIENCE↗

A simplified approach to characterizing a kilovoltage source spectrum for accurate dose computation

Purpose: To investigate and validate the clinical feasibility of using half-value layer (HVL) and peak tube potential (kVp) for characterizing a kilovoltage (kV) source spectrum for the purpose of computing kV x-ray dose accrued from imaging procedures. To use this approach to characterize a Varian Registered-Sign On-Board Imager Registered-Sign (OBI) source and perform experimental validation of a novel in-house hybrid dose computation algorithm for kV x-rays. Methods: We characterized the spectrum of an imaging kV x-ray source using the HVL and the kVp as the sole beam quality identifiers using third-party freeware Spektr to generate the spectra. We studied the sensitivity of our dose computation algorithm to uncertainties in the beam's HVL and kVp by systematically varying these spectral parameters. To validate our approach experimentally, we characterized the spectrum of a Varian Registered-Sign OBI system by measuring the HVL using a Farmer-type Capintec ion chamber (0.06 cc) in air and compared dose calculations using our computationally validated in-house kV dose calculation code to measured percent depth-dose and transverse dose profiles for 80, 100, and 125 kVp open beams in a homogeneous phantom and a heterogeneous phantom comprising tissue, lung, and bone equivalent materials. Results: The sensitivity analysis of the beam quality parameters (i.e., HVL, kVp, and field size) on dose computation accuracy shows that typical measurement uncertainties in the HVL and kVp ({+-}0.2 mm Al and {+-}2 kVp, respectively) source characterization parameters lead to dose computation errors of less than 2%. Furthermore, for an open beam with no added filtration, HVL variations affect dose computation accuracy by less than 1% for a 125 kVp beam when field size is varied from 5 Multiplication-Sign 5 cm{sup 2} to 40 Multiplication-Sign 40 cm{sup 2}. The central axis depth dose calculations and experimental measurements for the 80, 100, and 125 kVp energies agreed within 2% for the homogeneous and heterogeneous block phantoms, and agreement for the transverse dose profiles was within 6%. Conclusions: The HVL and kVp are sufficient for characterizing a kV x-ray source spectrum for accurate dose computation. As these parameters can be easily and accurately measured, they provide for a clinically feasible approach to characterizing a kV energy spectrum to be used for patient specific x-ray dose computations. Furthermore, these results provide experimental validation of our novel hybrid dose computation algorithm.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-F-T-28: Evaluation of BEBIG HDR Co-60 After-Loading System for Skin Cancer Treatment Using Conical Surface Applicator

Purpose: To evaluate the possibility of utilizing the BEBIG HDR 60Co remote after-loading system for malignant skin surface treatment using Monte Carlo (MC) simulation technique. Methods: First TG-43 parameters of BEBIG-Co-60 and Nucletron Ir-192-mHDR-V2 brachytherapy sources were simulated using MCNP6 code to benchmark the sources against the literature. Second a conical tungsten-alloy with 3-cm diameter of Planning-Target-Volume (PTV) at surface for use with a single stepping HDR source is designed. The HDR source is modeled parallel to treatment plane at the center of the conical applicator with a source surface distance (SSD) of 1.5-cm and a removable plastic end-cap with a 1-mm thickness. Third, MC calculated dose distributions from HDR Co-60 for conical surface applicator were compared with the simulated data using HDR Ir-192 source. The initial calculations were made with the same conical surface applicator (standard-applicator) dimensions as the ones used with the Ir-192 system. Fourth, the applicator wall-thickness for the Co-60 system was increased (doubled) to diminish leakage dose to levels received when using the Ir-192 system. With this geometry, percentage depth dose (PDD), and relative 2D-dose profiles in transverse/coronal planes were normalized at 3-mm prescription-depth evaluated along the central axis. Results: PDD for Ir-192 and Co-60 were similar with standard and thick-walled applicator. 2D-relative dose distribution of Co-60, inside the standard-conical-applicator, generated higher penumbra (7.6%). For thick-walled applicator, it created smaller penumbra (<4%) compared to Ir-192 source in the standard-conicalapplicator. Dose leakage outside of thick-walled applicator with Co-60 source was approximately equal (≤3%) with standard applicator using Ir-192 source. Conclusion: Skin cancer treatment with equal quality can be performed with Co-60 source and thick-walled conical applicators instead of Ir-192 with standard applicators. These conical surface applicator must be used with a protective plastic end-cap to eliminate electron contamination and over-dosage of the skin.

60 APPLIED LIFE SCIENCES↗

Switchgrass ( Panicum virgatum L.) cultivars have similar impacts on soil carbon and nitrogen stocks and microbial function

Abstract Switchgrass ( Panicum virgatum L.) production for biofuel has the potential to produce reasonable yields on lands not suited for conventional agriculture. We assessed nine switchgrass cultivars representing lowland and upland ecotypes grown for 11 years at a site in the upper Midwest USA for belowground differences in soil carbon and nitrogen stocks, soil organic matter fractions, and standing root biomass to 1 m depth. We also compared potential nitrogen mineralization and carbon substrate use through community‐level physiological profiling in surface soils (0–10 cm depth). Average yields and standing root biomass differed among cultivars and between ecotypes, but we found no significant cultivar‐related impacts on soil carbon and nitrogen stocks, on the distribution of particulate and mineral‐associated soil organic matter fractions, nor on potential nitrogen mineralization or microbial community‐level physiological profiles. That these traits did not differ among cultivars suggests that soil carbon and nitrogen gains under switchgrass are likely to be robust with respect to cultivar differences, and to this point not much affected by breeding efforts.

Agriculture↗

SU-E-T-451: Accuracy and Application of the Standard Imaging W1 Scintillator Dosimeter

Purpose: To evaluate the Standard Imaging W1 scintillator dosimeter in a range of clinical radiation beams to determine its range of possible applications. Methods: The W1 scintillator is a small perturbation-free dosimeter which is of interest in absolute and relative clinical dosimetry due to its small size and water equivalence. A single version of this detector was evaluated in Co-60 and linac photon and electron beams to investigate the following: linearity, sensitivity, precision, and dependence on electrometer type. In addition, depth-dose and cross-plane profiles were obtained in both photon and electron beams and compared with data obtained with wellbehaved ionization chambers. Results: In linac beams the precision and linearity was very impressive, with typical values of 0.3% and 0.1% respectively. Performance in a Co-60 beam was much poorer (approximately three times worse) and it is not clear whether this is due to the lower signal current or the effect of the continuous beam (rather than pulsed beam of the linac measurements). There was no significant difference in the detector reading when using either the recommended SI Supermax electrometer or two independent high-quality electrometers, except for low signal levels, where the Supermax exhibited an apparent threshold effect, preventing the measurement of the bremsstrahlung background in electron depth-dose curves. Comparisons with ion chamber measurements in linac beams were somewhat variable: good agreement was seen for cross-profiles (photon and electron beams) and electron beam depth-dose curves, generally within the 0.3% precision of the scintillator but systematic differences were observed as a function of measurement depth in photon beam depth-dose curves. Conclusion: A first look would suggest that the W1 scintillator has applications beyond small field dosimetry but performance appears to be limited to higher doserate and/or pulsed radiation beams. Further work is required to resolve discrepancies compared to ion chambers.

60 APPLIED LIFE SCIENCES↗

Continuous snow depth and temperature measurements from dense network of above-ground distributed temperature profiling systems from 2021-09-23 to 2024-08-23, Seward Peninsula, Alaska

The dataset contains temperature measurements from distributed temperature profiling (DTP) systems (Dafflon et al., 2022; Wielandt et al., 2022; Wang et al., 2024a; Fiolleau et al., 2024) deployed vertically above the ground surface at a large number of locations from 2021 to 2024. The research is designed to improve understanding of the local heterogeneity in snow depth and snow thermal insulation dynamics, as well as their interactions in a discontinuous permafrost region (Wang et al., 2025). The DTP systems were deployed at 96 locations in a watershed along the Nome-Teller road at mile marker 27 (T27) and at 54 locations on a hillslope along the Kougarok road at mile marker 64 (K64) in the Seward Peninsula, Alaska. The probe location information is stored in Probe_locations_T27.csv and Probe_locations_K64.csv. Temperature measurements were recorded at 15-minute intervals using high-precision digital sensors (accuracy: ±0.1°C, resolution: 0.0078°C). The temperature probes, either 1.4 m or 1.6 m long, contain sensors spaced every 5 cm or 10 cm along their length. The temperature data are stored in compressed files following the format: DTP_snow_air_temperature_(site)_(start)_(end).zip, where site is either T27 or K64, and start and end represent the time series period. Within each ZIP file, individual CSV files are named by probe ID and contain temperature records at different heights above the ground surface.This dataset also includes derived snow depth time series over three snow seasons, estimated from temperature measurements. Snow depth was estimated by identifying the consecutive sensor pair that exhibited the largest drop in high-frequency temperature fluctuations (detailed in the methods). These data are stored in: Snow_depths_flags_(site)_(start)_(end).csv, which includes snow depth time series and corresponding quality flags (defined in the methods) from different probes. Additionally, the dataset includes derived metrics and supporting measurements at selected locations over two snow seasons, contributing to the manuscript of Wang et al., 2025. These locations were chosen based on the availability of high-quality snow depth time series during both seasons. The additional data include: (1) Air temperature proxies measured from the top sensors on the pole when they were not buried by snow, stored in Air_temperature_proxies_(site)_(start)_(end).csv (2) Ground interface temperature, recorded at 3 cm above the ground, stored in Ground_interface_temperature_(site)_(start)_(end).csv (3) Site characteristics, including vegetation height, elevation, and the topographic position index (TPI) within a 50 m radius, stored in Selected_probe_locations_gps_vegheight_tpi_elevation_(site).csv. These metrics were derived from 1 m resolution summer LiDAR-based digital elevation models and digital surface models from Singhania et al., 2023, DOI:10.5440/1832016. Metadata files include data descriptions (_dd.csv) for tabular data. All included files are listed and described in xxxx_flmd.csv.This dataset is an updated version of a previous archive (Wang et al., 2024b, DOI: 10.15485/2475020), incorporating multiple seasons and improved snow depth estimation. Please note that due to large amount of information present in this dataset, many specificities associated with the acquisition of snow temperature, air temperature proxy and estimation of snow depth, and the future archiving of additional datasets on the soil temperature, thaw depth and soil characteristics at these locations, the author would welcome being contacted by people planning to use this dataset.The Next-Generation Ecosystem Experiments: Arctic (NGEE Arctic), was a research effort to reduce uncertainty in Earth System Models by developing a predictive understanding of carbon-rich Arctic ecosystems and feedbacks to climate. NGEE Arctic was supported by the Department of Energy's Office of Biological and Environmental Research.The NGEE Arctic project had two field research sites: 1) located within the Arctic polygonal tundra coastal region on the Barrow Environmental Observatory (BEO) and the North Slope near Utqiagvik (Barrow), Alaska and 2) multiple areas on the discontinuous permafrost region of the Seward Peninsula north of Nome, Alaska.Through observations, experiments, and synthesis with existing datasets, NGEE Arctic provided an enhanced knowledge base for multi-scale modeling and contributed to improved process representation at global pan-Arctic scales within the Department of Energy's Earth system Model (the Energy Exascale Earth System Model, or E3SM), and specifically within the E3SM Land Model component (ELM).

54 ENVIRONMENTAL SCIENCES↗

Utah FORGE: Temperature Contours at 200 m

The individual shapefiles in this dataset delineate estimated temperature contours (20, 40, 60, and 80 deg C) at a depth of 200 m in the Milford, Utah FORGE area. Contours were derived from 86 geothermal, gradient, and other wells drilled in the area since the mid-1970s with depths greater than 50 m. Conductive temperature profiles for wells less than 200 m were extrapolated to determine the temperature at the desired depth. Because 11 wells in the eastern section of the study area (in and around the Mineral Mountains) are at higher elevations compared to those closer to the center of the basin, temperature profiles were extrapolated to a constant elevation of 200 m below the 1830 m (6000 ft) a.s.l. datum (approximate elevation of alluvial fans at the base of the Mineral Mountains) to smooth the contours across the ridges and valleys.

15 GEOTHERMAL ENERGY↗