At least 1,189 records · Page 66

Photovoltaic effect on silicon–alumina–ferromagnet tunnel junction providing insights about spin-dependent molecular spintronics solar cells

The study focuses on the observation of the photovoltaic (PV) effect on Si/AlOx/FM semiconductor–insulator–ferromagnetic metal (SIFM) structure. Utilization of ~10 nm NiFe film as the top ferromagnet (FM) layer was permeable for sufficient light radiation necessary for reaching the silicon substrate for the generation of electron–hole pairs upon photoexcitation. The effect of light intensity and magnetic field was studied on the SIFM’s PV response. We also investigated the role of silicon doping and the AlOx tunnel barrier between Si and FM in exploring suitable band bending necessary for separating the electron–hole pairs. Increasing the dopant density in Si and a damaged AlOx tunnel barrier quenched the PV effect. Ferromagnet/Insulator/Ferromagnet (FMIFM) was also studied to gain deeper mechanistic insights into the spin-dependent photovoltaic effect observed on FM/AlOx/FM tunnel junction-based molecular spintronics devices. Bridging of magnetic molecules between the Si and FM electrodes of SIFM increased the overall device current by establishing additional parallel conduction channels along with the AlOx tunnel barrier. However, SIFM with molecular conduction channels did not produce a PV effect. This study reported the PV effect on well-designed SIFM and opened possibilities for exploring new systems. More importantly, this paper provided insights into the role of molecule-induced exchange coupling in transforming an ordinary, cheap, and widely available ferromagnet into a semiconductor-like material capable of showing PV.

14 SOLAR ENERGY↗

Ceramic distribution members for solid state electrolyte cells and method of producing

A solid state electrolyte cells apparatus and method of producing is disclosed. The apparatus can be used for separating oxygen from an oxygen-containing feedstock or as a fuel cell for reacting fluids. Cells can be stacked so that fluids can be introduced and removed from the apparatus through ceramic distribution members having ports designed for distributing the fluids in parallel flow to and from each cell. The distribution members can also serve as electrodes to membranes or as membrane members between electrodes. The distribution member design does not contain any horizontal internal ports which allows the member to be thin. A method of tape casting in combination with an embossing method allows intricate radial ribs and bosses to be formed on each distribution member. The bosses serve as seals for the ports and allow the distribution members to be made without any horizontal internal ports.

Clark, Douglas J.↗

Method of producing ceramic distribution members for solid state electrolyte cells

A solid state electrolyte cells apparatus and method of producing is disclosed. The apparatus can be used for separating oxygen from an oxygen-containing feedstock or as a fuel cell for reacting fluids. Cells can be stacked so that fluids can be introduced and removed from the apparatus through ceramic distribution members having ports designed for distributing the fluids in parallel flow to and from each cell. The distribution members can also serve as electrodes to membranes or as membrane members between electrodes, The distribution member design does not contain any horizontal internal ports which allows the member to be thin. A method of tape casting in combination with an embossing method allows intricate radial ribs and bosses to be formed on each distribution member. The bosses serve as seals for the ports and allow the distribution members to be made without any horizontal internal ports.

Clark, Douglas J.↗

Tuning the Selectivity of Carboxylic Acid–Based Eutectic Solvents for the Dissolution and Electrochemical Separation of Metal Oxides

Extracting metals from natural resources and recovering from waste materials with less-hazardous solvents is essential for sustainable technological advancements. The commonly employed method utilizes harsh chemicals for metal dissolution and the ensuing separation. Here, in this study, we examined the potential of eutectic solvents (types III and IV) as alternative media for the selective dissolution of metals and metal oxides and their subsequent electrochemical separation. Notably, type III eutectics composed of betaine:acetic acid and triazole:lactic acid exhibited excellent solubility for cobalt oxide (24.1 g·L –1 ) and copper oxide (30.5 g·L –1 ), respectively. In comparison, the type IV eutectic mixture of Ca(NO 3 ) 2 ·4H 2 O:acetic acid demonstrated the highest conductivity and lowest viscosity with solubility for both copper oxide (6.1 g·L –1 ) and metallic copper (5.4 g·L –1 from a used electronic circuit). Using a Ca(NO 3 ) 2 ·4H 2 O:acetic acid mixture, copper was selectively dissolved from a waste printed circuit board and subsequently electrodeposited onto a nickel electrode. These findings highlight the tunability of DESs for the selective recovery of metals from electronic waste, offering a promising approach for sustainable metal recycling and resource recovery.

electrodeposition↗

IonCCD™ for direct position-sensitive charged-particle detection: from electrons and keV ions to hyperthermal biomolecular ions

A novel charged-particle sensitive, pixel based detector array is described and its usage is demonstrated for a variety of applications, from detection of elemental particles (electrons) to hyper-thermal large biomolecular positive and negative ions including keV light atomic and molecular ions. The array detector is a modified light-sensitive charged coupled device (CCD). The IonCCDTM was engineered for direct charged particle detection by replacing the semi-conductor part of the CCD pixel by a conductor1. In contrast with the CCD, where the semi-conductive pixel is responsible for electron-hole pair formation upon photon bombardment, the IonCCD uses a capacitor coupled to the conductive electrode for direct charge integration. The detector can be operated from atmospheric pressure to high vacuum since no high voltages are needed. The IonCCD, presented in this work is an array of 2126 active pixels with 21 um pixel width and 3 um pixel gap. The detection area is 1.5x51mm2 where 1.5 mm and 51 mm are pixel and detector array length, respectively. The result is a one-dimensional position-sensitive detector with 24 um spatial resolution and 88 % pixel area ratio (PAR). In this work we demonstrate the capabilities and the performance of the detector. For the first time we show the direct detection of 250 eV electrons providing linearity response and detection efficiency of the IonCCD as function of electron beam current. Using positive ions from and electron impact source (E-I), we demonstrate that the detection efficiency of the IonCCD is virtually independent of particle energy [250 eV, 1250 eV], particle impact angle [45o, 90o] and particle flux. By combining the IonCCD with a double focusing sector field of Mattauch-Herzog geometry (M-H), we demonstrate fast acquisition of mass spectra in direct air sniffing mode. A first step towards fast in vivo breath analysis is presented. Detection of hyper-thermal biomolecular ions produced using an electrospray ionization source (ESI) is presented. The IonCCD was used as beam profiler to characterize the beam shape and intensity of 15 eV protonated and deprotonated biomolecular ions at the exit of an RF only collisional quadrupole. We present simultaneous detection of 140 eV doubly protonated biomolecular ions when the IonCCD is combined with the M-H analyzer. The latter, demonstrates the possibility of simultaneous separation and micro-array deposition of biological material using a miniature sector field.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

First Flight of the Gamma-Ray Imager Polarimeter for Solar Flares (GRIPS) Instrument

The Gamma-Ray Imager/Polarimeter for Solar ares (GRIPS) instrument is a balloon-borne telescope designed to study solar-flare particle acceleration and transport. We describe GRIPS's first Antarctic long-duration flight in January 2016 and report preliminary calibration and science results. Electron and ion dynamics, particle abundances and the ambient plasma conditions in solar flares can be understood by examining hard X-ray (HXR) and gamma-ray emission (20 keV to 10 MeV). Enhanced imaging, spectroscopy and polarimetry of flare emissions in this energy range are needed to study particle acceleration and transport questions. The GRIPS instrument is specifically designed to answer questions including: What causes the spatial separation between energetic electrons producing hard X-rays and energetic ions producing gamma-ray lines? How anisotropic are the relativistic electrons, and why can they dominate in the corona? How do the compositions of accelerated and ambient material vary with space and time, and why? GRIPS's key technological improvements over the current solar state of the art at HXR/gamma-ray energies, the Reuven Ramaty High Energy Solar Spectroscopic Imager (RHESSI), include 3D position-sensitive germanium detectors (3D-GeDs) and a single-grid modulation collimator, the multi-pitch rotating modulator (MPRM). The 3D-GeDs have spectral FWHM resolution of a few hundred keV and spatial resolution less than 1cu mm. For photons that Compton scatter, usually greater or equal to 150 keV, the energy deposition sites can be tracked, providing polarization measurements as well as enhanced background reduction through Compton imaging. Each of GRIPS's detectors has 298 electrode strips read out with ASIC/FPGA electronics. In GRIPS's energy range, indirect imaging methods provide higher resolution than focusing optics or Compton imaging techniques. The MPRM grid-imaging system has a single-grid design which provides twice the throughput of a bi-grid imaging system like RHESSI. The grid is composed of 2.5 cm deep tungsten-copper slats, and quasi-continuous FWHM angular coverage from 12.5-162 arcsecs are achieved by varying the slit pitch between 1-13 mm. This angular resolution is capable of imaging the separate magnetic loop footpoint emissions in a variety of are sizes. In comparison, RHESSI's 35-arcsec resolution at similar energies makes the footpoints resolvable in only the largest ares.

Duncan, Nicole↗

Toward Polarization-Switched Molecular Pumps

Pumping of fluids is universally performed by using mechanical or thermal compressors. We demonstrate for the first time a new solid-state molecular pumping mechanism induced by switching the adsorption affinity for a gas through polarization of a chromophore under an applied electric field. Mass spectrometry was used to trace refrigerant gas (difluoromethane) uptake on a chromophore-coated capacitor under applied voltage and subsequent desorption when the voltage and electrode polarization was removed showing an exchange capacity of 0.11 mol of refrigerant per liter of chromophore. Calorimetry confirmed a reversible enthalpy change of 9 Kcal/mol in the polarization-induced sorption-desorption process. Here, the present work establishes the principle and feasibility of non-mechanical molecular pumping, which can be exploited for refrigeration, catalysis, gas separation, among many other potential applications.

42 ENGINEERING↗

Resistive foil edge grading for accelerator and other high voltage structures

In a structure or device having a pair of electrical conductors separated by an insulator across which a voltage is placed, resistive layers are formed around the conductors to force the electric potential within the insulator to distribute more uniformly so as to decrease or eliminate electric field enhancement at the conductor edges. This is done by utilizing the properties of resistive layers to allow the voltage on the electrode to diffuse outwards, reducing the field stress at the conductor edge. Preferably, the resistive layer has a tapered resistivity, with a lower resistivity adjacent to the conductor and a higher resistivity away from the conductor. Generally, a resistive path across the insulator is provided, preferably by providing a resistive region in the bulk of the insulator, with the resistive layer extending over the resistive region.

42 ENGINEERING↗

Molecular Design Principle of All-organic Dyes for Dye-Sensitized Solar Cells

All-organic dyes have shown promising potential as an effective sensitizer in dye-sensitized solar cells (DSSCs). The design concept of all-organic dyes to improve light-to-electric-energy conversion is discussed based on the absorption, electron injection, dye regeneration, and recombination. How the electron-donor–acceptor-type framework can provide better light harvesting through bandgap-tuning and why proper arrangement of acceptor/anchoring groups within a conjugated dye frame is important in suppressing improper charge recombination in DSSCs are discussed. Separating the electron acceptor from the anchoring unit in the donor–acceptor-type organic dye would be a promising strategy to reduce recombination and improve photocurrent generation.

14 SOLAR ENERGY↗

Stress evolution in lithium metal electrodes

The potential advantages of lithium metal anodes have received widespread attention (highest capacity, lowest reduction potential, etc). However, the poor stability of Li metal / liquid electrolyte interfaces leads to chronic problems, such as dendrite formation and capacity loss. The possible impact of mechanical effects on interface stability and dendrite formation are difficult to probe directly. In this study, stress evolution during lithium plating and stripping was monitored with precise in situ measurements. The data obtained with different film thicknesses made it possible to separate the stresses associated with the lithium metal and the solid electrolyte interphase (SEI). The results show that significant stresses are created in the SEI films. Based on this, a basic model of wrinkling-ratcheting-delamination is also presented. This analysis indicates that plasticity in a growing Li film can enhance surface wrinkling, and thus lead to morphological destabilization of a planar growth front.

25 ENERGY STORAGE↗

A Four‐Electron Sulfur Electrode Hosting a Cu 2+ /Cu + Redox Charge Carrier

Abstract The elemental sulfur electrode with Cu 2+ as the charge carrier gives a four‐electron sulfur electrode reaction through the sequential conversion of S↔CuS↔Cu 2 S. The Cu‐S redox‐ion electrode delivers a high specific capacity of 3044 mAh g −1 based on the sulfur mass or 609 mAh g −1 based on the mass of Cu 2 S, the completely discharged product, and displays an unprecedently high potential of sulfur/metal sulfide reduction at 0.5 V vs. SHE. The Cu‐S electrode also exhibits an extremely low extent of polarization of 0.05 V and an outstanding cycle number of 1200 cycles retaining 72 % of the initial capacity at 12.5 A g −1 . The remarkable utility of this Cu‐S cathode is further demonstrated in a hybrid cell that employs an Zn metal anode and an anion‐exchange membrane as the separator, which yields an average cell discharge voltage of 1.15 V, the half‐cell specific energy of 547 Wh kg −1 based on the mass of the Cu 2 S/carbon composite cathode, and stable cycling over 110 cycles.

Wu, Xianyong↗

Characterization of applied fields for ion mobility separations in traveling wave based structures for lossless ion manipulations (SLIM)

Ion mobility (IM) is rapidly gaining attention for the analysis of biomolecules due to the ability to distinguish the shapes of ions. However, conventional constant electric field drift tube IM has limited resolving power, constrained by practical limitations on the path length and maximum applied voltage. The implementation of traveling waves (TW) in IM removes the latter limitation, allowing higher resolution to be achieved using extended path lengths. These can be readily obtainable in structures for lossless ion manipulations (SLIM), which are fabricated from electric fields that are generated by appropriate potentials applied to arrays of electrodes patterned on two parallel surfaces. In this work we have investigated the relationship between the various SLIM variables, such as electrode dimensions, inter-surface gap, and the TW applied voltages, that directly impact the fields experienced by ions. Ion simulation and theoretical calculations have been utilized to understand the dependence of SLIM geometry and effective electric field. The variables explored impact both ion confinement and the observed IM resolution in Structures for Lossless Ion Manipulations (SLIM) modules.

Hamid, Ahmed M.↗

Cubine, a Quasi Two-Dimensional Copper–Bismuth Nanosheet

We report on the discovery of a quasi two-dimensional copper–bismuth nano sheet from ab initio calculations, which we call cubine. According to our predictions, single layers of cubine can be isolated from the recently reported high-pressure CuBi bulk material at an energetic cost of merely ≈20 meV/Å2, comparable to values to separate single layers of graphene from graphite. Our calculations suggest that cubine has remarkable electronic and electrochemical properties: It is a superconductor with a moderate electron–phonon coupling λ = 0.5, leading to Tc ≈ 1 K, and can be readily intercalated with lithium with a high diffusibility, rendering it a promising candidate material to boost the rate capacity of current electrodes in lithium-ion batteries.

Amsler, Maximilian↗