At least 1,189 records · Page 66

Selecting a Control Strategy for Plug and Process Loads

Plug and Process Loads (PPLs) are building loads that are not related to general lighting, heating, ventilation, cooling, and water heating, and typically do not provide comfort to the building occupants. PPLs in commercial buildings account for almost 5% of U.S. primary energy consumption. On an individual building level, they account for approximately 25% of the total electrical load in a minimally code-compliant commercial building, and can exceed 50% in an ultra-high efficiency building such as the National Renewable Energy Laboratory's (NREL) Research Support Facility (RSF) (Lobato et al. 2010). Minimizing these loads is a primary challenge in the design and operation of an energy-efficient building. A complex array of technologies that measure and manage PPLs has emerged in the marketplace. Some fall short of manufacturer performance claims, however. NREL has been actively engaged in developing an evaluation and selection process for PPLs control, and is using this process to evaluate a range of technologies for active PPLs management that will cap RSF plug loads. Using a control strategy to match plug load use to users' required job functions is a huge untapped potential for energy savings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy use of residential safety, security, and health devices

Miscellaneous electrical loads (MELs) are responsible for a significant fraction of energy consumption in buildings. This paper addresses one category of MELs: Safety, Security, and Health Devices (SSHDs). Common SSHDs include: electrical life safety equipment, smoke alarms, radon mitigation fans, and home oxygen concentrators. The installation or use of these devices is dictated by building codes, health providers, insurance companies, and other entities—none of which would ordinarily consider energy efficiency a priority. For this project, the most important residential devices were explored in terms of their governing regulations, functions, technologies, and energy use. The power consumption of 41 life safety SSHDs were measured. Individual power consumption of life safety devices is very small but many are typically required in every home. Devices performing the same functions have wide ranges in power use. Opportunities for reducing SSHD energy use were investigated, the results are summarized, and recommendations are made for further actions that could be taken to reduce SSHD energy use. Finally, SSHDs identified in this paper are responsible for at least one percent of current U.S. residential electricity consumption, but that number will climb steadily as existing buildings are upgraded and new types of SSHDs appear.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Historical perspectives of BEPU research in US

Civilian nuclear energy started in earnest in the 1950s and experienced rapid growth in 1960-80s with increasingly larger reactors. These reactors were initially regulated based on the experience from the smaller reactors, but this could not be applied to the larger power reactors. Therefore, in 1974 the US Nuclear Regulatory Commission set up safety requirements based on defense in depth in 10 CFR 50.46, and set of guidance in 10 CFR 50 presented in Appendix K, for models and simulations of reactor safety analyses, to ensure conservatism in predicted safety parameters. These methods resulted in both conservative safety margins as well as economic and operational penalties. In the late 1970s and early 1980s, a large number of experiential programs provided data that allowed for the creation of best estimate models. These best estimate models showed the conservatism in Appendix K models. In 1988-89, USNRC modified the regulations and allowed the use of best estimate models provided they were coupled to a reliable and defensible measure of uncertainty in the prediction of safety parameters. This change in regulation strongly encouraged global activity for the development of best estimate codes and methods. To aide in this development, the USNRC provided one acceptable approach, the Code Scaling, Acceptability and Uncertainty Evaluation Methodology (CSAU). This approach was later refined in the Evaluation Model Development and Assessment Process (EMDAP).

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Strategies to Save 50% Site Energy in Grocery and General Merchandise Stores

This paper summarizes the methodology and main results of two recently published Technical Support Documents. These reports explore the feasibility of designing general merchandise and grocery stores that use half the energy of a minimally code-compliant building, as measured on a whole-building basis. We used an optimization algorithm to trace out a minimum cost curve and identify designs thatsatisfy the 50% energy savings goal. We started from baseline building energy use and progressed to more energy-efficient designs by sequentially adding energy design measures (EDMs). Certain EDMs figured prominently in reaching the 50% energy savings goal for both building types: (1) reduced lighting power density; (2) optimized area fraction and construction of view glass or skylights, orboth, as part of a daylighting system tuned to 46.5 fc (500 lux); (3) reduced infiltration with a main entrance vestibule or an envelope air barrier, or both; and (4) energy recovery ventilators, especially in humid and cold climates. In grocery stores, the most effective EDM, which was chosen for all climates, was replacing baseline medium-temperature refrigerated cases with high-efficiencymodels that have doors.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The Role of Building Codes and Controls in Enhancing Community Resilience

Countries, states, and cities around the world are seeking to enhance power sector resilience through a combination of policy and technology. However, few of these efforts fully incorporate the built environment into power sector planning. Buildings account for more than a third of the global annual energy consumption and more than 60% of the annual electricity consumption. As such, buildings play a critical role in enhancing resilience in the power sector. Buildings can aid in power sector resilience by increasing power system flexibility, shaving and shifting demand, and providing on-site energy generation. All of these strategies require incentives to encourage participation. This paper presents an overview of energy management strategies to better incorporate building design and operation in power sector resilience planning.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Development of a standard capture efficiency test method for residential kitchen ventilation

Cooking activities are a major source of indoor air pollutants. To control pollutants generated from cooking activities, a range hood is commonly used in residential kitchens. Several building codes require that a range hood be installed in new homes to control pollutants from cooking, and the required airflow rates for range hoods are specified by indoor air quality standards. However, airflow alone does not show how much of the cooking pollutants are exhausted by the range hood. A better metric to evaluate range hood indoor air quality performance is capture efficiency -- the fraction of contaminants emitted during cooking that are exhausted directly to the outside via the range hood. The current article summarizes the development of a range hood capture efficiency test method for use in laboratory testing and equipment rating.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Development of a Standard Test Method for Reducing the Uncertainties in Measuring the Capture Efficiency of Range Hoods

Cooking activities are a major source of indoor air pollutants. To control pollutants generated from cooking activities, a range hood is commonly used in residential kitchens. Several building codes require that a range hood be installed in new homes to control pollutants from cooking, and the required airflow rates for range hoods are specified by indoor air quality (IAQ) standards. However, air flow alone does not tell us how much of the cooking pollutants are exhausted by the range hood. A better metric to evaluate range hood IAQ performance is capture efficiency (CE)—the fraction of contaminants emitted during cooking that are exhausted directly to the outside via the range hood. This paper summarizes the development of a range hood CE test method for use in laboratory testing and equipment rating.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy efficiency in wireless communication systems

Wireless communication systems and methods utilize one or more remote terminals, one or more base terminals, and a communication channel between the remote terminal(s) and base terminal(s). The remote terminal applies a direct sequence spreading code to a data signal at a spreading factor to provide a direct sequence spread spectrum (DSSS) signal. The DSSS signal is transmitted over the communication channel to the base terminal which can be configured to despread the received DSSS signal by a spreading factor matching the spreading factor utilized to spread the data signal. The remote terminal and base terminal can dynamically vary the matching spreading factors to adjust the data rate based on an estimation of operating quality over time between the remote terminal and base terminal such that the amount of data being transmitted is substantially maximized while providing a specified quality of service.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Assessment of MELCOR condensation models with the presence of noncondensable gas in natural convection flow regime

Condensation of steam vapor is an important mode of energy removal from the reactor containment. The presence of noncondensable gas complicates the process and makes it difficult to model. MELCOR, one of the more widely used system codes for containment analyses, uses the heat and mass transfer analogy to model condensation heat transfer. To investigate previously reported nodalization-dependence in natural convection flow regime, MELCOR condensation model as well as other models are studied. The nodalization-dependence issue is resolved by using physical length from the actual geometry rather than node size of each control volume as the characteristic length scale for MELCOR containment analyses. At the transition to turbulent natural convection regime, the McAdams correlation for convective heat transfer produces a better prediction compared to the original MELCOR model. The McAdams correlation is implemented in MELCOR and the prediction is validated against a set of experiments on a scaled AP600 containment. The MELCOR with our implemented model produces improved predictions. For steam molar fractions in the gas mixture greater than about 0.58, the predictions are within the uncertainty margin of the measurements. The simulation results still underestimate the heat transfer from the gas-steam mixture, implying that conservative predictions are provided.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Building America Case Study: Selecting Ventilation Systems for Existing Homes (Fact Sheet)

This document addresses adding -or improving - mechanical ventilation systems to existing homes. The purpose of ventilation is to remove contaminants from homes, and this report discusses where, when, and how much ventilation is appropriate in a home, including some discussion of relevant codes and standards. Advantages, disadvantages, and approximate costs of various system types are presented along with general guidelines for implementing the systems in homes. CARB intends for this document to be useful to decision makers and contractors implementing ventilation systems in homes. Choosing the "best" system is not always straightforward; selecting a system involves balancing performance, efficiency, cost, required maintenance, and several other factors. It is the intent of this document to assist contractors in making more informed decisions when selecting systems. Ventilation is an integral part of a high-performance home. With more air-sealed envelopes, a mechanical means of removing contaminants is critical for indoor environmental quality and building durability.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

NUMERICAL VERIFICATION OF THE RELAP-7 CORE CHANNEL SINGLE-PHASE MODEL

The RELAP-7 code is the next generation of nuclear reactor system safety analysis code being developed at the Idaho National Laboratory (INL). All the physics in RELAP-7 are fully coupled and the errors resulted from the traditional operator-splitting approach are eliminated. By using 2nd order methods in both time and space and eliminating operator-splitting errors, the numerical error of RELAP-7 can be minimized. Numerical verification is the process to verify the orders of numerical methods. It is an important part of modern verification and validation process. The core channel component in RELAP-7 is designed to simulate coolant flow as well as the conjugated heat transfer between coolant flow and the fuel rod. A special treatment at fuel centerline to avoid numerical singularity for the cylindrical heat conduction in the continuous finite element mesh is discussed. One steady state test case and one fast power up transient test case are utilized for the verification of the core channel model with single-phase flow. Analytical solution for the fuel pin temperature and figures of merit such as peak clad temperature and peak fuel temperature are used to define numerical errors. These cases prove that the mass and energy are well conserved and 2nd order convergence rates for both time and space are achieved in the core channel model.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

State-Level Employment Projections for Four Clean Energy Technologies in 2025 and 2030

As states and local governments weigh how to spur economic growth, stimulate job creation, and simultaneously adapt to meet climate goals, modern energy codes, and energy demand, this report provides a simple and transparent method to estimate the size of the workforce needed to support modeled deployments for energy efficiency in buildings, stationary battery energy storage (BES), solar photovoltaics (PV), and land-based wind in 2025 and 2030. In addition to a straightforward estimation method, this report includes state-level job estimates for two different deployment scenarios: a business-as-usual scenario and a more accelerated deployment scenario. The scope of the technologies included in this report is limited to four key energy technologies within the power sector that have strong job growth prospects and widespread geographic deployment potential. Although the included technologies are not all-encompassing, they have generated specific interest from state energy offices across the nation.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

A Buildings Module for the Stochastic Energy Deployment System

The U.S. Department of Energy (USDOE) is building a new long-range (to 2050) forecasting model for use in budgetary and management applications called the Stochastic Energy Deployment System (SEDS), which explicitly incorporates uncertainty through its development within the Analytica(R) platform of Lumina Decision Systems. SEDS is designed to be a fast running (a few minutes), user-friendly model that analysts can readily run and modify in its entirety through a visual programming interface. Lawrence Berkeley National Laboratory is responsible for implementing the SEDS Buildings Module. The initial Lite version of the module is complete and integrated with a shared code library for modeling demand-side technology choice developed by the National Renewable Energy Laboratory (NREL) and Lumina. The module covers both commercial and residential buildings at the U.S. national level using an econometric forecast of floorspace requirement and a model of building stock turnover as the basis for forecasting overall demand for building services. Although the module is fundamentally an engineering-economic model with technology adoption decisions based on cost and energy performance characteristics of competing technologies, it differs from standard energy forecasting models by including considerations of passive building systems, interactions between technologies (such as internal heat gains), and on-site power generation.

25 ENERGY STORAGE↗

Building America Research Benchmark Definition, Updated December 19, 2008

To track progress toward aggressive multi-year, whole-house energy savings goals of 40%–70% and onsite power production of up to 30%, the U.S. Department of Energy (DOE) Residential Buildings Program and the National Renewable Energy Laboratory (NREL) developed the Building America (BA) Research Benchmark in consultation with the BA industry teams. The Benchmark is generally consistent with mid-1990s standard practice, as reflected in the Home Energy Rating System (HERS) Technical Guidelines (RESNET 2002), with additional definitions that allow the analyst to evaluate all residential end-uses, an extension of the traditional HERS rating approach that focuses on space conditioning and hot water. Unlike the reference homes used for HERS, ENERGY STAR ® , and most energy codes, the Benchmark represents typical construction at a fixed point in time so it can be used as the basis for Building America’s multi-year energy savings goals without the complication of chasing a “moving target.” As time passes, we expect energy codes to become increasingly energy efficient compared to the Benchmark as better construction practices and more efficient equipment become commonplace in the market. A series of user profiles, intended to represent the behavior of a “standard” set of occupants, was created for use in conjunction with the Benchmark. The Benchmark is intended for use with detached and attached single-family housing only. It is not suitable for multi-family housing as written. Energy analysis of a Prototype compared to the Benchmark can be performed with any software tool that complies with the BA Performance Analysis Procedures (Hendron et al. 2004). In addition, NREL will provide examples of technology packages that can be used to achieve different source energy savings based on BEopt analysis results (Anderson and Roberts, 2008). These technology packages, or alternative packages that provide equivalent source energy savings, may be used to demonstrate minimum whole house source energy savings for BA Gate reviews.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Economic analysis of CCUS: Accelerated development for CO 2 EOR and storage in residual oil zones under the context of 45Q tax credit

Residual oil zones (ROZ) undergoing CO 2 Enhanced Oil Recovery (CO 2 -EOR) may benefit from specific strategies to maximize their value. We evaluated several strategies for producing from a Permian Basin, West Texas, USA field’s ROZ. This ROZ lies below the main pay zone (MPZ) of the field. Such brownfield ROZs occur in the Permian Basin and elsewhere. Since brownfield ROZs are hydraulically connected to the MPZs, development sequences and schemes influence oil production, CO 2 storage, and net present value (NPV). We conducted economic assessments of various CO 2 injection/production schemes in the stacked ROZ-MPZ reservoir based on flow simulations of a high-resolution geocellular model built from wireline logs and core data and calibrated through production history matching. Flow simulations of water alternating gas (WAG) injection, such as switching injection from the MPZ to the ROZ and commingled production, were studied. Simulation results showed that simultaneous CO 2 injection into the MPZ and ROZ lead to the largest oil production and, generally, the largest NPV. If instead, CO 2 was simultaneously injected into the MPZ and ROZ, then into the ROZ alone, this maximized CO 2 storage. CO 2 storage can be used as a tax credit under the Internal Revenue Code, Section 45Q. Storage performance depends on the development approach and WAG ratio. Developing the ROZ increased storage compared to only producing from the MPZ. The WAG ratio to maximize oil production did not always yield the largest NPV. These findings are potentially applied to other Brownfield ROZs, which are common below San Andres reservoirs in the Permian Basin and other basins. ROZ development can increase oilfields’ NPV and carbon storage potential. Our study can serve as an analog for similar reservoirs. Here this work provides valuable insights into the further optimization of brownfield ROZ development and information for operators to plan to develop stacked ROZ-MPZ reservoirs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Measure Guideline: Selecting Ventilation Systems for Existing Homes

This document addresses adding -or improving - mechanical ventilation systems to existing homes. The purpose of ventilation is to remove contaminants from homes, and this report discusses where, when, and how much ventilation is appropriate in a home, including some discussion of relevant codes and standards. Advantages, disadvantages, and approximate costs of various system types are presented along with general guidelines for implementing the systems in homes. CARB intends for this document to be useful to decision makers and contractors implementing ventilation systems in homes. Choosing the "best" system is not always straightforward; selecting a system involves balancing performance, efficiency, cost, required maintenance, and several other factors. It is the intent of this document to assist contractors in making more informed decisions when selecting systems. Ventilation is an integral part of a high-performance home. With more air-sealed envelopes, a mechanical means of removing contaminants is critical for indoor environmental quality and building durability.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Monitoring of Unvented Roofs with Fibrous Insulation, Diffusion Vents, and Interior Vapor Control in a Cold Climate

Unvented roof assemblies have been accepted in North American building codes since 2007; code-compliant construction calls for a minimum thickness of “air-impermeable insulation” (based on climate zone) to avoid cold-weather condensation and moisture risks. This is typically implemented with polyurethane spray foam insulation; however, negatives of this material include high first cost and possible adverse environmental impacts. Implementing unvented roofs in a moisture-safe manner with air-permeable fibrous fill insulations (e.g., fiberglass or cellulose) could potentially reduce the first cost of unvented roof designs, allowing for more widespread use. Building unvented roofs in a cost-effective, airtight, and moisture-safe manner opens up options for high-performance house designers and builders.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

HPC4Mobilty w/ UCB

The purpose of this project is to examine the energy impact of urban-scale traffic for the Los Angeles Basin by developing and implementing a scalable traffic assignment model. An energy optimization function will be posed and when integrated into the optimization code for travel assignment it can be mathematically proven to converge. The energy optimization function can then be compared to the typical travel time optimization that is traditionally used in traffic assignment models. The analysis will begin with static traffic assignment models with the routing for all origin and destinations computed in parallel on high performance computing facilities. Convergence of the numerical methods rely on the solution of convex programs (or extensions of these). This step will mostly consist of demonstrating the ability to parallelize the Frank Wolfe algorithm on various platforms. This work will contribute to LBNL’s efforts to develop new processes, analytical tools, program designs, and business models to advance the state of the art in next-generation sustainable transportation solutions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗