Search NASA⌕ Search

SEARCH · Search NASA

Results for “multiple precision”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,189 records · Page 66

Precise Tracking of the Magellan and Pioneer Venus Orbiters by Same-Beam Interferometry. Part 2: Orbit Determination Analysis

A new radio metric positioning technique has demonstrated improved orbit determination accuracy for the Magellan and Pioneer Venus Orbiter orbiters. The new technique, known as Same-Beam Interferometry (SBI), is applicable to the positioning of multiple planetary rovers, landers, and orbiters which may simultaneously be observed in the same beamwidth of Earth-based radio antennas. Measurements of carrier phase are differenced between spacecraft and between receiving stations to determine the plane-of-sky components of the separation vector(s) between the spacecraft. The SBI measurements complement the information contained in line-of-sight Doppler measurements, leading to improved orbit determination accuracy. Orbit determination solutions have been obtained for a number of 48-hour data arcs using combinations of Doppler, differenced-Doppler, and SBI data acquired in the spring of 1991. Orbit determination accuracy is assessed by comparing orbit solutions from adjacent data arcs. The orbit solution differences are shown to agree with expected orbit determination uncertainties. The results from this demonstration show that the orbit determination accuracy for Magellan obtained by using Doppler plus SBI data is better than the accuracy achieved using Doppler plus differenced-Doppler by a factor of four and better than the accuracy achieved using only Doppler by a factor of eighteen. The orbit determination accuracy for Pioneer Venus Orbiter using Doppler plus SBI data is better than the accuracy using only Doppler data by 30 percent.

Folkner, W. M.↗

Airborne-Managed Spacing in Multiple Arrival Streams

A significant bottleneck in the current air traffic system occurs at the runway. Expanding airports and adding new runways will help solve this problem; however, this comes at a significant cost, financially, politically and environmentally. A complementary solution is to safely increase the capacity of current runways. This can be achieved by precise spacing at the runway threshold with a resulting reduction in the spacing buffer required under today s operations. At the NASA Langley Research Center, the Advanced Air Transportation Technologies (AATT) Project is investigating airborne technologies and procedures that will assist the pilot in achieving precise spacing behind another aircraft. This new spacing clearance instructs the pilot to follow speed cues from a new on-board guidance system called Airborne Merging and Spacing for Terminal Arrivals (AMSTAR). AMSTAR receives Automatic Dependent Surveillance-Broadcast (ADS-B) reports from the leading aircraft and calculates the appropriate speed for the ownership to fly in order to achieve the desired spacing interval, time or distance-based, at the runway threshold. Since the goal is overall system capacity, the speed guidance algorithm is designed to provide system benefit over individual efficiency. This paper discusses the concept of operations and design of AMSTAR to support airborne precision spacing. Results from the previous stage of development, focused only on in-trail spacing, are discussed along with the evolution of the concept to include merging of converging streams of traffic. This paper also examines how this operation might support future wake vortex-based separation and other advances in terminal area operations. Finally, the research plan for the merging capabilities, to be performed during the summer and fall of 2004 is presented.

Barmore, Bryan↗

High Multiplicity Infection by HIV-1 in Men Who Have Sex with Men

Elucidating virus-host interactions responsible for HIV-1 transmission is important for advancing HIV-1 prevention strategies. To this end, single genome amplification (SGA) and sequencing of HIV-1 within the context of a model of random virus evolution has made possible for the first time an unambiguous identification of transmitted/founder viruses and a precise estimation of their numbers. Here, we applied this approach to HIV-1 env analyses in a cohort of acutely infected men who have sex with men (MSM) and found that a high proportion (10 of 28; 36%) had been productively infected by more than one virus. In subjects with multivariant transmission, the minimum number of transmitted viruses ranged from 2 to 10 with viral recombination leading to rapid and extensive genetic shuffling among virus lineages. A combined analysis of these results, together with recently published findings based on identical SGA methods in largely heterosexual (HSX) cohorts, revealed a significantly higher frequency of multivariant transmission in MSM than in HSX [19 of 50 subjects (38%) versus 34 of 175 subjects (19%); Fisher’s exact p = 0.008]. To further evaluate the SGA strategy for identifying transmitted/founder viruses, we analyzed 239 overlapping 59 and 39 half genome or env-only sequences from plasma viral RNA (vRNA) and blood mononuclear cell DNA in an MSM subject who had a particularly well-documented virus exposure history 3–6 days before symptom onset and 14–17 days before peak plasma viremia (47,600,000 vRNA molecules/ml). All 239 sequences coalesced to a single transmitted/founder virus genome in a time frame consistent with the clinical history, and a molecular clone of this genome encoded replication competent virus in accord with model predictions. Higher multiplicity of HIV-1 infection in MSM compared with HSX is consistent with the demonstrably higher epidemiological risk of virus acquisition in MSM and could indicate a greater challenge for HIV-1 vaccines than previously recognized.

59 BASIC BIOLOGICAL SCIENCES↗

Exploring the NΛ–NΣ coupled system with high precision correlation techniques at the LHC

The interaction of Λ and Σ hyperons (Y) with nucleons (N) is strongly influenced by the coupled-channel dynamics. Due to the small mass difference of the NΛ and NΣ systems, the sizable coupling strength of the NΣ↔NΛ processes constitutes a crucial element in the determination of the NΛ interaction. In this letter we present the most precise measurements on the interaction of pΛ pairs, from zero relative momentum up to the opening of the NΣ channel. The correlation function in the relative momentum space for pΛ ⊕$\bar{p}$$\bar{Λ}$ pairs measured in high-multiplicity triggered pp collisions at $\sqrt{s}$=13 TeV at the LHC is reported. The opening of the inelastic NΣ channels is visible in the extracted correlation function as a cusp-like structure occurring at relative momentum k*=289 MeV/c. This represents the first direct experimental observation of the NΣ↔NΛ coupled channel in the pΛ system. The correlation function is compared with recent chiral effective field theory calculations, based on different strengths of the NΣ↔NΛ transition potential. A weaker coupling, as possibly supported by the present measurement, would require a more repulsive three-body NNΛ interaction for a proper description of the Λ in-medium properties, which has implications on the nuclear equation of state and for the presence of hyperons inside neutron stars.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Automated defect analysis in electron microscopic images

Electron microscopy and defect analysis are a cornerstone of materials science, as they offer detailed insights on the microstructure and performance of a wide range of materials and material systems. Building a robust and flexible platform for automated defect recognition and classification in electron microscopy will result in the completion of analysis orders of magnitude faster after images are recorded, or even online during image acquisition. Automated analysis has the potential to be significantly more efficient, accurate, and repeatable than human analysis, and it can scale with the increasingly important methods of automated data generation. Herein, an automated recognition tool is developed based on a computer vison–based approach; it sequentially applies a cascade object detector, convolutional neural network, and local image analysis methods. We demonstrate that the automated tool performs as well as or better than manual human detection in terms of recall and precision and achieves quantitative image/defect analysis metrics close to the human average. The proposed approach works for images of varying contrast, brightness, and magnification. Furthermore, these promising results suggest that this and similar approaches are worth exploring for detecting multiple defect types and have the potential to locate, classify, and measure quantitative features for a range of defect types, materials, and electron microscopic techniques.

47 OTHER INSTRUMENTATION↗

A multi-point laser Doppler vibrometer with fiber-based configuration

Laser Doppler vibrometer (LDV) is a non-contact optical interferometric system to measure vibrations of structures and machines with a high precision. Normal LDV can only offer a single-point measurement. Scanning LDV is usually impractical to do measurement on transient events. In this paper, a fiber-based self-synchronized multi-point LDV is proposed. The multiple laser beams with different frequency shifts are generated from one laser source. The beams are projected onto a vibrating object, reflected and interfered with a common reference beam. The signal including vibration information of multiple spatial points is captured by one single-pixel photodetector. The optical system is mainly integrated by fiber components for flexibility in measurement. Two experiments are conducted to measure a steady-state simple harmonic vibration of a cantilever beam and a transient vibration of a beam clamped at both ends. In the first measurement, a numerical interpolation is applied to reconstruct the mode shape with increased number of data points. The vibration mode obtained is compared with that from FEM simulation. In transient vibration measurement, the first five resonant frequencies are obtained. The results show the new-reported fiber-based multipoint LDV can offer a vibration measurement on various spatial points simultaneously. With the flexibility of fiber configuration, it becomes more practical for dynamic structural evaluation in industrial areas.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

DESI 2024 IV: Baryon Acoustic Oscillations from the Lyman alpha forest

We present the measurement of Baryon Acoustic Oscillations (BAO) from the Lyman-α(Lyα) forest of high-redshift quasars with the first-year dataset of the Dark Energy Spectroscopic Instrument (DESI). Our analysis uses over 420 000 Lyα forest spectra and their correlation with the spatial distribution of more than 700 000 quasars. An essential facet of this work is the development of a new analysis methodology on a blinded dataset. We conducted rigorous tests using synthetic data to ensure the reliability of our methodology and findings before unblinding. Additionally, we conducted multiple data splits to assess the consistency of the results and scrutinized various analysis approaches to confirm their robustness. For a given value of the sound horizon (r d ), we measure the expansion at z eff = 2.33 with 2% precision, H(z eff ) = (239.2 ± 4.8) (147.09 Mpc /r d ) km/s/Mpc. Similarly, we present a 2.4% measurement of the transverse comoving distance to the same redshift, DM(z eff ) = (5.84 ± 0.14) (r d /147.09 Mpc) Gpc. Together with other DESI BAO measurements at lower redshifts, these results are used in a companion paper to constrain cosmological parameters.

79 ASTRONOMY AND ASTROPHYSICS↗

Expansion of the tmRNA sequence database and new tools for search and visualization

Abstract Transfer–messenger RNA (tmRNA) contributes essential tRNA-like and mRNA-like functions during the process of trans-translation, a mechanism of quality control for the translating bacterial ribosome. Proper tmRNA identification benefits the study of trans-translation and also the study of genomic islands, which frequently use the tmRNA gene as an integration site. Automated tmRNA gene identification tools are available, but manual inspection is still important for eliminating false positives. We have increased our database of precisely mapped tmRNA sequences over 50-fold to 97 179 unique sequences. Group I introns had previously been found integrated within a single subsite within the TψC-loop; they have now been identified at four distinct subsites, suggesting multiple founding events of invasion of tmRNA genes by group I introns, all in the same vicinity. tmRNA genes were found in metagenomic archaeal genomes, perhaps a result of misbinning of bacterial sequences during genome assembly. With the expanded database, we have produced new covariance models for improved tmRNA sequence search and new secondary structure visualization tools.

59 BASIC BIOLOGICAL SCIENCES↗

Cascaded Sapphire Fiber Bragg Gratings Inscribed by Femtosecond Laser for Molten Steel Studies

This research reports a distributed fiber optic high-temperature sensing system tailored for applications in the steel industry and various other sectors. Recent advancements in optical sensor technology have led to the exploration of sapphire crystal fibers as a solution for sensing in harsh environments. Utilizing a femtosecond (fs) laser, cascaded fiber Bragg gratings (FBGs) were meticulously fabricated within a multimode sapphire optical fiber. These FBGs endowed the system with distributed sensing capabilities and underwent rigorous testing under extreme temperatures, reaching up to 1800 °C. Here, the study delves into the investigation of the FBG reflection spectrum, facilitated by the development of a sophisticated multimode demodulation system, which contributed to the attainment of precise temperature measurements with a performance accuracy of 99.9%. Demonstrating exceptional thermal stability, the sapphire FBGs endured temperatures of 1600 °C for a sustained duration of 22 h. Furthermore, this article explores the application of distributed temperature sensing employing multiple sapphire FBGs, showcasing their utility in temperature measurements related to molten steel studies.

47 OTHER INSTRUMENTATION↗

Gradient-Based Novelty Detection Boosted by Self-Supervised Binary Classification

Novelty detection aims to automatically identify out-of-distribution (OOD) data, without any prior knowledge of them. It is a critical step in data monitoring, behavior analysis and other applications, helping enable continual learning in the field. Conventional methods of OOD detection perform multi-variate analysis on an ensemble of data or features, and usually resort to the supervision with OOD data to improve the accuracy. In reality, such supervision is impractical as one cannot anticipate the anomalous data. In this paper, we propose a novel, self-supervised approach that does not rely on any pre-defined OOD data: (1) The new method evaluates the Mahalanobis distance of the gradients between the in-distribution and OOD data. (2) It is assisted by a self-supervised binary classifier to guide the label selection to generate the gradients, and maximize the Mahalanobis distance. In the evaluation with multiple datasets, such as CIFAR-10, CIFAR-100, SVHN and TinyImageNet, the proposed approach consistently outperforms state-of-the-art supervised and unsupervised methods in the area under the receiver operating characteristic (AUROC) and area under the precision-recall curve (AUPR) metrics. We further demonstrate that this detector is able to accurately learn one OOD class in continual learning.

Sun, Jingbo↗

A strainmeter array as the fulcrum of novel observatory sites along the Alto Tiberina Near Fault Observatory

Fault slip is a complex natural phenomenon involving multiple spatiotemporal scales from seconds to days to weeks. To understand the physical and chemical processes responsible for the full fault slip spectrum, a multidisciplinary approach is highly recommended. The Near Fault Observatories (NFOs) aim at providing high-precision and spatiotemporally dense multidisciplinary near-fault data, enabling the generation of new original observations and innovative scientific products. The Alto Tiberina Near Fault Observatory is a permanent monitoring infrastructure established around the Alto Tiberina fault (ATF), a 60 km long low-angle normal fault (mean dip 20°), located along a sector of the Northern Apennines (central Italy) undergoing an extension at a rate of about 3 mm yr –1 . The presence of repeating earthquakes on the ATF and a steep gradient in crustal velocities measured across the ATF by GNSS stations suggest large and deep (5–12 km) portions of the ATF undergoing aseismic creep. Both laboratory and theoretical studies indicate that any given patch of a fault can creep, nucleate slow earthquakes, and host large earthquakes, as also documented in nature for certain ruptures (e.g., Iquique in 2014, Tōhoku in 2011, and Parkfield in 2004). Nonetheless, how a fault patch switches from one mode of slip to another, as well as the interaction between creep, slow slip, and regular earthquakes, is still poorly documented by near-field observation. With the strainmeter array along the Alto Tiberina fault system (STAR) project, we build a series of six geophysical observatory sites consisting of 80–160 m deep vertical boreholes instrumented with strainmeters and seismometers as well as meteorological and GNSS antennas and additional seismometers at the surface. By covering the portions of the ATF that exhibits repeated earthquakes at shallow depth (above 4 km) with these new observatory sites, we aim to collect unique open-access data to answer fundamental questions about the relationship between creep, slow slip, dynamic earthquake rupture, and tectonic faulting.

58 GEOSCIENCES↗

Symbolic computation of recurrence equations for the Chebyshev series solution of linear ODE's

If a linear ordinary differential equation with polynomial coefficients is converted into integrated form then the formal substitution of a Chebyshev series leads to recurrence equations defining the Chebyshev coefficients of the solution function. An explicit formula is presented for the polynomial coefficients of the integrated form in terms of the polynomial coefficients of the differential form. The symmetries arising from multiplication and integration of Chebyshev polynomials are exploited in deriving a general recurrence equation from which can be derived all of the linear equations defining the Chebyshev coefficients. Procedures for deriving the general recurrence equation are specified in a precise algorithmic notation suitable for translation into any of the languages for symbolic computation. The method is algebraic and it can therefore be applied to differential equations containing indeterminates.

Geddes, K. O.↗

Radar Interferometer for Topographic Mapping of Glaciers and Ice Sheets

A report discusses Ka-band (35-GHz) radar for mapping the surface topography of glaciers and ice sheets at high spatial resolution and high vertical accuracy, independent of cloud cover, with a swath-width of 70 km. The system is a single- pass, single-platform interferometric synthetic aperture radar (InSAR) with an 8-mm wavelength, which minimizes snow penetration while remaining relatively impervious to atmospheric attenuation. As exhibited by the lower frequency SRTM (Shuttle Radar Topography Mission) AirSAR and GeoSAR systems, an InSAR measures topography using two antennas separated by a baseline in the cross-track direction, to view the same region on the ground. The interferometric combination of data received allows the system to resolve the pathlength difference from the illuminated area to the antennas to a fraction of a wavelength. From the interferometric phase, the height of the target area can be estimated. This means an InSAR system is capable of providing not only the position of each image point in along-track and slant range as with a traditional SAR but also the height of that point through interferometry. Although the evolution of InSAR to a millimeter-wave center frequency maximizes the interferometric accuracy from a given baseline length, the high frequency also creates a fundamental problem of swath coverage versus signal-to-noise ratio. While the length of SAR antennas is typically fixed by mass and stowage or deployment constraints, the width is constrained by the desired illuminated swath width. As the across-track beam width which sets the swath size is proportional to the wavelength, a fixed swath size equates to a smaller antenna as the frequency is increased. This loss of antenna size reduces the two-way antenna gain to the second power, drastically reducing the signal-to-noise ratio of the SAR system. This fundamental constraint of high-frequency SAR systems is addressed by applying digital beam-forming (DBF) techniques to synthesize multiple simultaneous receive beams in elevation while maintaining a broad transmit illumination. Through this technique, a high antenna gain on receive is preserved, thereby reducing the required transmit power and thus enabling high-frequency SARs and high-precision InSAR from a single spacecraft.

Moller, Delwyn K.↗

High Precision, Absolute Total Column Ozone Measurements from the Pandora Spectrometer System: Comparisons with Data from a Brewer Double Monochromator and Aura OMI

We present new, high precision, high temporal resolution measurements of total column ozone (TCO) amounts derived from ground-based direct-sun irradiance measurements using our recently deployed Pandora single-grating spectrometers. Pandora's small size and portability allow deployment at multiple sites within an urban air-shed and development of a ground-based monitoring network for studying small-scale atmospheric dynamics, spatial heterogeneities in trace gas distribution, local pollution conditions, photochemical processes and interdependencies of ozone and its major precursors. Results are shown for four mid- to high-latitude sites where different Pandora instruments were used. Comparisons with a well calibrated double-grating Brewer spectrometer over a period of more than a year in Greenbelt MD showed excellent agreement and a small bias of approximately 2 DU (or, 0.6%). This was constant with slant column ozone amount over the full range of observed solar zenith angles (15-80), indicating adequate Pandora stray light correction. A small (1-2%) seasonal difference was found, consistent with sensitivity studies showing that the Pandora spectral fitting TCO retrieval has a temperature dependence of 1% per 3K, with an underestimation in temperature (e.g., during summer) resulting in an underestimation of TCO. Pandora agreed well with Aura-OMI (Ozone Measuring Instrument) satellite data, with average residuals of <1% at the different sites when the OMI view was within 50 km from the Pandora location and OMI-measured cloud fraction was <0.2. The frequent and continuous measurements by Pandora revealed significant short-term (hourly) temporal changes in TCO, not possible to capture by sun-synchronous satellites, such as OMI, alone.

Ozone↗

Event Reconstruction in the NOvA Experiment

The NOvA experiment observes oscillations in two channels (electron-neutrino appearance and muon-neutrino disappearance) using a predominantly muon-neutrino NuMI beam. The Near Detector records multiple overlapping neutrino interactions in each event and the Far Detector has a large background of cosmic rays due to being located on the surface. The oscillation analyses rely on the accurate reconstruction of neutrino interactions in order to precisely measure the neutrino energy and identify the neutrino flavor and interaction mode. Similarly, measurements of neutrino cross sections using the Near Detector require accurate identification of the particle content of each interaction. A series of pattern recognition techniques have been developed to split event records into individual spatially and temporally separated interactions, to estimate the interaction vertex, and to isolate and classify individual particles within the event. This combination of methods to achieve full event reconstruction in the NOvA detectors has discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Mass Spectrometry–Based Proteogenomics: New Therapeutic Opportunities for Precision Medicine

Proteogenomics refers to the integration of comprehensive genomic, transcriptomic, and proteomic measurements from the same samples with the goal of fully understanding the regulatory processes converting genotypes to phenotypes, often with an emphasis on gaining a deeper understanding of disease processes. Although specific genetic mutations have long been known to drive the development of multiple cancers, gene mutations alone do not always predict prognosis or response to targeted therapy. The benefit of proteogenomics research is that information obtained from proteins and their corresponding pathways provides insight into therapeutic targets that can complement genomic information by providing an additional dimension regarding the underlying mechanisms and pathophysiology of tumors. This review describes the novel insights into tumor biology and drug resistance derived from proteogenomic analysis while highlighting the clinical potential of proteogenomic observations and advances in technique and analysis tools.

60 APPLIED LIFE SCIENCES↗

Multiple scattering in planetary atmospheres

Methods for solving radiative transfer problems within the extended visible spectrum in planetary atmospheres are reviewed for use by the nonspecialist. Emphasis is placed on rapid, approximate procedures for the determination of such quantities as the plane and spherical (Bond) albedo, surface illumination, absorbed energy, limb darkening, phase curve, and spectra. Precise numerical methods and analytical results are also discussed. Recent approaches to such complications as atmospheric inhomogeneity and reflection from a porous regolith are described briefly.

Irvine, W. M.↗

“MODAL NOISE” IN SINGLE-MODE FIBERS: A CAUTIONARY NOTE FOR HIGH PRECISION RADIAL VELOCITY INSTRUMENTS

Exploring the use of single-mode fibers (SMFs) in high precision Doppler spectrometers has become increasingly attractive since the advent of diffraction-limited adaptive optics systems on large-aperture telescopes. Spectrometers fed with these fibers can be made significantly smaller than typical “seeing-limited” instruments, greatly reducing cost and overall complexity. Importantly, classical mode interference and speckle issues associated with multi-mode fibers, also known as “modal noise,” are mitigated when using SMFs, which also provide perfect radial and azimuthal image scrambling. However, SMFs do support multiple polarization modes, an issue that is generally ignored for larger-core fibers given the large number of propagation modes. Since diffraction gratings used in most high resolution astronomical instruments have dispersive properties that are sensitive to incident polarization changes, any birefringence variations in the fiber can cause variations in the efficiency profile, degrading illumination stability. Here we present a cautionary note outlining how the polarization properties of SMFs can affect the radial velocity (RV) measurement precision of high resolution spectrographs. This work is immediately relevant to the rapidly expanding field of diffraction-limited, extreme precision RV spectrographs that are currently being designed and built by a number of groups.

79 ASTRONOMY AND ASTROPHYSICS↗