Experimental research of graphite behavior under the air ingress accident condition of High Temperature Gas-cooled Reactor - 18752
As the major component of both cladding and grid spacer materials of High Temperature Gas-cooled Reactor (HTGR), graphite plays an important role on heat removal during the severe accident sequence. However, its heat transfer behavior in high temperature condition may be affected by the oxidation of graphite when the air or steam ingresses in an accident. In this research, an experiment was conducted to analyze the graphite heat transfer behavior in high temperature oxidable environment. An assembly including two graphite rings was used as the test section. It was heated up by a tungsten wire, which is installed inside the inner graphite ring and be joule heated. Temperature was measured by several K-type thermos-couples in certain positions. Argon gas was injected in advance to avoid the unwanted oxidation by the oxygen in the air. Air was injected into the gap between two graphite rings once the temperature of the inner ring reached target point to create the oxidable environment. Based on the results, a rapid increase of inner graphite ring's temperature can be observed after starting injected the air, and a rapid decrease after stopped the injection. It might due to the chemical reaction heat during the graphite surface oxidation. By comparing the steady state before and after air injection, the inner specimen s temperature is a little bit lower after the oxidation, which suggests that its ability of radiation heat transfer might be enhanced a little bit by oxidation. By visualized the test section, coarser surface at the inner graphite ring can be observed after the oxidation. In addition, about 8.9% mass loss of the oxidized graphite can also be found from the posttest examination. (authors)