Search NASA⌕ Search

SEARCH · Search NASA

Results for “quality monitoring”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,189 records · Page 66

On The Processing of Log Files for Monitoring Antenna Health

In order to improve the quality of geodetic results, we have developed an infrastructure for timely processing of telemetry from IVS observing stations. We check every hour for new log files with telemetry from both VLBI observing sessions, single dish experiments, and stow-in data collection and automatically process them. The telemetry data we use is the system temperature, phase calibration phases and amplitudes, system equivalent flux density, and the differences between formatter clock and GPS clock. For the system temperature and phase calibration, processing includes filtering out outliers and computing averages and rms of the scatter in each scan. Furthermore, for the phase calibration we also compute the group delay and detect spurious signals. Cleaned and post-processed telemetry is archived. Our process detects abnormalities, such as, anomalously high system temperature, unstable phase calibration phases, jumps in the GPS and formatter clock differences, and others. With our procedure, the latency of detection of station abnormalities is reduced to less than two hours. Early detection of abnormalities reduces the amount of affected data since station personnel get early alerts. We discuss our experience of running this system since 2022.

Phase Calibration↗

On The Processing of Log Files for Monitoring Antenna Health

In order to improve the quality of geodetic results, we have developed an infrastructure for timely processing of telemetry from IVS observing stations. We check every hour for new log files with telemetry from both VLBI observing sessions, single dish experiments, and stow-in data collection and automatically process them. The telemetry data we use is the system temperature, phase calibration phases and amplitudes, system equivalent flux density, and the differences between formatter clock and GPS clock. For the system temperature and phase calibration, processing includes filtering out outliers and computing averages and rms of the scatter in each scan. Furthermore, for the phase calibration we also compute the group delay and detect spurious signals. Cleaned and post-processed telemetry is archived. Our process detects abnormalities, such as, anomalously high system temperature, unstable phase calibration phases, jumps in the GPS and formatter clock differences, and others. With our procedure, the latency of detection of station abnormalities is reduced to less than two hours. Early detection of abnormalities reduces the amount of affected data since station personnel get early alerts. We discuss our experience of running this system since 2022.

VLBI↗

Interannual variability and trends of summertime PM2.5-based air quality in the Intermountain West

Abstract Summertime air quality is a growing public health concern in the populated region of Northern Utah. Whereas winter air pollution is highly linked with local atmospheric temperature inversions associated with upper atmospheric high-pressure and radiational cooling in valleys, the relationship between climate factors and the frequency of poor air quality during summer is still unknown. Analyzing the last 20 years of data, we demonstrated that summertime unhealthy days (as defined by PM2.5 air quality index level) in Northern Utah highly correlate with the number of dry-hot days, wildfire size, and an upper atmospheric ridge over the Northwestern United States. The persistent atmospheric ridge enhances lightning-caused fire burned areas in northwestern states and then transports the wildfire smoke toward Northern Utah. Similarly, climate model simulations confirm observational findings, such as an increasing trend of the upper atmospheric ridge and summertime dry days in the northwestern states. Such metrics developed in this study could be used to establish longer-term monitoring and seasonal forecasting for air quality and its compounding factors, which is currently limited to forecasting products for only several days.

54 ENVIRONMENTAL SCIENCES↗

Development of Large Scale Extrusion Deposition for Structural Applications

Large Scale Extrusion Deposition (LSED) is an evolving additive manufacturing (AM) technology that research, such as that taking place at Oak Ridge National Laboratory (ORNL) and companies like Local Motors, are continuing to utilize and develop new applications. A major LSED application of interest has been molds and tooling as it allows for much shorter production time and lower cost. However, interest has been expanding into using LSED for more structural applications due to more frequent use of high performing polymer composites as feedstock. The use of LSED for structural applications is of particular interest to Local Motors as it is currently being used to create commercially viable, energy efficient electric vehicles. LSED offers a unique opportunity when compared to traditional manufacturing methods as it can significantly reduce the number of components necessary, while decreasing embodied energy and carbon emissions. Even with these benefits however, it is important that LSED is properly understood from a structural aspect as this field has not been as heavily researched as tooling. To ensure a high level of safety and repeatability is an essential responsibility of a manufacturer whose products are structural in nature. As such it is important to understand the materials and LSED process to make structural objects that the manufacturer can be confident in. The main goals of this project were to: develop and investigate materials that are of interest for structural LSED applications, further develop and understand the current machines used in LSED and develop simulations tools of LSED and the mechanical properties of the created structure. Material development focused on composite materials that have high mechanical properties and are stable in a variety of environments. The materials were tested to determine their as printed mechanical and thermal properties as these are necessary for simulations. Once the materials were investigated thoroughly, it allowed for simulations to be performed to compare to experimental data with simulations. Materials were also vetted to determine candidates for multi-material printing. The machine development focused around the areas of process monitoring, non-destructive evaluation, and quality control. Finally, the goal of the simulations was to develop a realistic model of printed structures, including in-process simulation and dynamic simulation. The routes to get to some of these goals and the depth in which they were investigated changed throughout the project due to personnel changes and the COVID-19 pandemic. This project resulted in many valuable results such as the development of an nondestructive evaluation (NDE) technique for interlayer defects, proof of simulation for warpage in simple parts, the development and utilization of a profilometer to monitor a print for defects or inconsistencies, thorough investigation of a material used commercially for structural LSED applications and valuable experimental data on the applicability and advantages of multi-material crush structures versus their neat counterparts by creation and testing of samples.

36 MATERIALS SCIENCE↗

Overview of GSICS visible calibration methods.

Global Space-based Inter-Calibration System (GSICS) is an international collaborative effort initiated in 2005 by the World Meteorological Organization (WMO) and the Coordination Group for Meteorological Satellites (CGMS) to 1-monitor, 2-improve and 3-harmonize the quality of observations from operational weather and environmental satellites of the Global Observing System (GOS). GSICS aims at ensuring consistent accuracy among space-based observations worldwide for climate monitoring, weather forecasting, and environmental applications by 1-monitoring instrument performance, 2-operational inter-calibration of satellite instruments, 3-radiometrically scaling observations to absolute reference standards, 4-recalibration of archived datasets. Although many of the GSIC visible inter-calibration methods are based on medium pixel-level imagers such as MODIS, VIIRS, AVHRR, and geostationary sensors, the methods are applicable to high spatial resolution imagery such as Landsat. For sensor inter-calibration efforts, coincident ray-matched reflectance pairs are used to transfer the calibration from the reference to the target instrument. Spectral band adjustment factors (SBAF) are applied to account for any spectral band differences. For sensor stability monitoring, PICS, deep convective cloud (DCC) and polar ice Earth viewed targets are utilized. GSICS uses the moon for stability monitoring by using the GSICS Implementation of the USGS Robotic Lunar Observatory (ROLO) model (GIRO). GSICS is looking forward to the launch of CLARREO on the international space station (ISS) in 2023. The CLARREO hyperspectral reflective solar band (RSB) sensor will establish an absolute calibration reference in space, which will characterize invariant targets and will inter-calibrate concurrent sensors. Examples of these calibration methods will be presented at the workshop.

Visible calibration methods↗

MO-A-16A-01: QA Procedures and Metrics: In Search of QA Usability

Radiation therapy has undergone considerable changes in the past two decades with a surge of new technology and treatment delivery methods. The complexity of radiation therapy treatments has increased and there has been increased awareness and publicity about the associated risks. In response, there has been proliferation of guidelines for medical physicists to adopt to ensure that treatments are delivered safely. Task Group recommendations are copious, and clinical physicists' hours are longer, stretched to various degrees between site planning and management, IT support, physics QA, and treatment planning responsibilities.Radiation oncology has many quality control practices in place to ensure the delivery of high-quality, safe treatments. Incident reporting systems have been developed to collect statistics about near miss events at many radiation oncology centers. However, tools are lacking to assess the impact of these various control measures. A recent effort to address this shortcoming is the work of Ford et al (2012) who recently published a methodology enumerating quality control quantification for measuring the effectiveness of safety barriers. Over 4000 near-miss incidents reported from 2 academic radiation oncology clinics were analyzed using quality control quantification, and a profile of the most effective quality control measures (metrics) was identified.There is a critical need to identify a QA metric to help the busy clinical physicists to focus their limited time and resources most effectively in order to minimize or eliminate errors in the radiation treatment delivery processes. In this symposium the usefulness of workflows and QA metrics to assure safe and high quality patient care will be explored.Two presentations will be given:Quality Metrics and Risk Management with High Risk Radiation Oncology ProceduresStrategies and metrics for quality management in the TG-100 Era Learning Objectives: Provide an overview and the need for QA usability metrics: Different cultures/practices affecting the effectiveness of methods and metrics. Show examples of quality assurance workflows, Statistical process control, that monitor the treatment planning and delivery process to identify errors. To learn to identify and prioritize risks and QA procedures in radiation oncology. Try to answer the question: Can a quality assurance program aided by quality assurance metrics help minimize errors and ensure safe treatment delivery. Should such metrics be institution specific.

07 ISOTOPE AND RADIATION SOURCES↗

Report of AAPM Therapy Physics Committee Task Group 74: In-air output ratio, S{sub c}, for megavoltage photon beams

The concept of in-air output ratio (S{sub c}) was introduced to characterize how the incident photon fluence per monitor unit (or unit time for a Co-60 unit) varies with collimator settings. However, there has been much confusion regarding the measurement technique to be used that has prevented the accurate and consistent determination of S{sub c}. The main thrust of the report is to devise a theoretical and measurement formalism that ensures interinstitutional consistency of S{sub c}. The in-air output ratio, S{sub c}, is defined as the ratio of primary collision water kerma in free-space, K{sub p}, per monitor unit between an arbitrary collimator setting and the reference collimator setting at the same location. Miniphantoms with sufficient lateral and longitudinal thicknesses to eliminate electron contamination and maintain transient electron equilibrium are recommended for the measurement of S{sub c}. The authors present a correction formalism to extrapolate the correct S{sub c} from the measured values using high-Z miniphantom. Miniphantoms made of high-Z material are used to measure S{sub c} for small fields (e.g., IMRT or stereotactic radiosurgery). This report presents a review of the components of S{sub c}, including headscatter, source-obscuring, and monitor-backscattering effects. A review of calculation methods (Monte Carlo and empirical) used to calculate S{sub c} for arbitrary shaped fields is presented. The authors discussed the use of S{sub c} in photon dose calculation algorithms, in particular, monitor unit calculation. Finally, a summary of S{sub c} data (from RPC and other institutions) is included for QA purposes.

61 RADIATION PROTECTION AND DOSIMETRY↗

Surface Characterization of Carbon Fiber Reinforced Polymers by Picosecond Laser Induced Breakdown Spectroscopy

Adhesive bonding of composite materials requires reliable monitoring and detection of surface contaminants as part of a vigorous quality control process to assure robust and durable bonded structures. Surface treatment and effective monitoring prior to bonding are essential in order to obtain a surface which is free from contaminants that may lead to inferior bond quality. In this study, the focus is to advance the laser induced breakdown spectroscopy (LIBS) technique by using pulse energies below 100 μJ (μLIBS) for the detection of low levels of silicone contaminants in carbon fiber reinforced polymer (CFRP) composites. Various CFRP surface conditions were investigated by LIBS using ∼10 ps, 355 nm laser pulses with pulse energies below 30 μJ. Time-resolved analysis was conducted to optimize the gate delay and gate width for the detection of the C I emission line at 247.9 nm to monitor the epoxy resin matrix of CFRP composites and the Si I emission line at 288.2 nm for detection of silicone contaminants in CFRP. To study the surface sensitivity to silicone contamination, CFRP surfaces were coated with polydimethylsiloxane (PDMS), the active ingredient in many mold release agents. The presence of PDMS was studied by inspecting the Si I emission lines at 251.6 nm and 288.2 nm. The measured PDMS areal densities ranged from 0.15 to 2 μg/cm(sup 2). LIBS measurements were performed before and after laser surface ablation. The results demonstrate the successful detection of PDMS thin layers on CFRP using picosecond μLIBS.

Rodolfo Ledesma↗

West Valley Demonstration Project (WVDP) Annual Site Environmental Report (ASER) for Calendar Year 2023

The report, prepared for the U.S. Department of Energy West Valley Demonstration Project office (DOE-WVDP), summarizes the environmental protection program at the WVDP for calendar year (CY) 2023. Monitoring and surveillance of the facilities used by the DOE are conducted to verify protection of public health and safety and the environment. The report is a key component of DOE’s effort to keep the public informed of environmental conditions at the WVDP. The quality assurance protocols applied to the environmental monitoring program ensure the validity and accuracy of the monitoring data. In addition to demonstrating compliance with environmental laws, regulations, and directives, evaluation of data collected in 2023 continued to indicate that WVDP activities pose no threat to public health or safety, or to the environment.

Record of Decision↗

West Valley Demonstration Project (WVDP) (Annual Site Environmental Report (ASER), Calendar Year 2022)

The report, prepared for the U.S. Department of Energy West Valley Demonstration Project office (DOE-WVDP), summarizes the environmental protection program at the WVDP for calendar year (CY) 2022. Monitoring and surveillance of the facilities used by the DOE are conducted to verify protection of public health and safety and the environment. The report is a key component of DOE’s effort to keep the public informed of environmental conditions at the WVDP. The quality assurance protocols applied to the environmental monitoring program ensure the validity and accuracy of the monitoring data. In addition to demonstrating compliance with environmental laws, regulations, and directives, evaluation of data collected in 2022 continued to indicate that WVDP activities pose no threat to public health or safety, or to the environment.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

West Valley Demonstration Project Annual Site Environmental Report (CY2019)

The report, prepared for the U.S. Department of Energy West Valley Demonstration Project office (DOE-WVDP), summarizes the environmental protection program at the WVDP for calendar year (CY) 2019. Monitoring and surveillance of the facilities used by the DOE are conducted to verify protection of public health and safety and the environment. The report is a key component of DOE’s effort to keep the public informed of environmental conditions at the WVDP. The quality assurance protocols applied to the environmental monitoring program ensure the validity and accuracy of the monitoring data. In addition to demonstrating compliance with environmental laws, regulations, and directives, evaluation of data collected in 2019 continued to indicate that WVDP activities pose no threat to public health or safety, or to the environment.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Laser Disdrometer Quantities (LDQUANTS) and Video Disdrometer Quantities (VDISQUANTS) Value-Added Products Report

Disdrometers are useful instruments that measure the distribution of raindrop sizes (drop size distribution: DSD) and the associated rainfall rates/accumulation as those raindrops fall to the ground. These DSDs are a quantity of interest to members of the modeler and observational communities. However, use of disdrometer data for model evaluation, radar monitoring, or other activities requires careful quality control and processing for key DSD properties of interest (e.g., the number concentration of drops) to ensure appropriate physical (scattering, fall speed) assumptions. The U.S. Department of Energy Atmospheric Radiation Measurement (ARM) Laser Disdrometer Quantities and Video Disdrometer Quantities Value-Added Product (LDQUANTS/VDISQUANTS VAP) uses standard methods from Tokay et al. (e.g., 2013, 2014) to filter drops with unrealistic fall speeds. Further, it estimates several microphysical/geophysical quantities of parameterized DSDs (gamma or exponential assumption type fitting methods) as in previous disdrometer studies and ARM long-term efforts (e.g., Testud et al. 2001, Giangrande et al. 2014, Thompson et al. 2015). Disdrometers are also beneficial for cross-checks with other instrumentation, including rain gauges and radars. To support research interests and related radar monitoring activities, this product calculates radar equivalent quantities, including dual polarization radar quantities (e.g., Z, Differential Reflectivity ZDR, etc.), using T-Matrix scattering and additional wavelength, temperature, and drop shape assumptions (e.g., Thurai et al. 2007). All of these efforts allow disdrometer data sets to become more useful and easily handled by modeling and observational studies, or routine instrumentation checks.

47 OTHER INSTRUMENTATION↗

Cleaned 5-Minute Resolution Air Quality and Meteorological Data from Nine TCEQ CAMS Sites in Houston, Texas (Nov 2021 – Oct 2022)

These data encompass 5-minute air monitoring and meteorological observations collected in the greater Houston, Texas metropolitan region, at nine (9) Continuous Ambient Monitoring Stations (CAMS) operated by the Texas Commission on Environmental Quality (TCEQ) between November 1, 2021 and October 31, 2022. The CAMS sites (CAMS 1, 8, 35, 45, 148, 403, 405, 410, and 1052) were chosen because their instrumentation includes measurements of PM2.5. These sites also provide continuous multi-parameter air-quality and meteorological measurements. Particulate matter (PM2.5, PM10) was sampled along with several trace gases, including ozone (O3), nitrogen oxides (NO, NO2, NOx), sulfur dioxide (SO2), and carbon monoxide (CO). The data set also contains standard surface meteorological parameters (temperature, humidity, pressure, wind speed, and wind direction). Several sites also include AutoGC-based measurements of volatile organic compounds (VOCs). Air monitoring instruments deployed at the selected sites comprise the following systems: BAM-1020 or TEOM (PM2.5), Thermo Scientific TEI 49i (O3), TEI 42i (NOx), and AutoGCs (VOCs). This data set is similar to the data included within the houairq5mX1.00 datastream, except for a few additional quality control steps. A systematic data cleaning and verification process was performed on the data set to ensure its quality and preparation for analysis. Removal of non-numeric status flags (e.g., [LIM], [QAS], [SPZ], [CAL], [PMA], [AQI], [SPN], [MAL]) was accomplished by employing rule-based string parsing to extract valid numerical values. Missing entries were set to -9999; however, invalid or anomalous values (e.g., 99999) were retained as originally reported by the TCEQ to preserve data provenance. The time sequence was verified for completeness, removal of duplicates, and uniformity at 5-minute intervals. Column labeling was standardized, and corresponding values were assessed for physical plausibility. All timestamps in the data set were reported in Coordinated Universal Time (UTC) as provided by the TCEQ. Further, the latitude and longitude coordinates were added for each CAMS site. A subset of the data (June 1–September 30, 2022) has been used in the following publication: Subba et al. 2025. “Implications of sea breeze circulations on boundary layer aerosols in the southern coastal Texas region.” EGUsphere 2025: 1–49, https://doi.org/10.5194/egusphere-2025-2659.

latitude↗

Four Years of Airborne Measurements of Wildfire Emissions in California, with a Focus on the Evolution of Emissions During the Soberanes Megafire

Biomass burning is an important source of trace gases and particles which can influence air quality on local, regional, and global scales. With wildfire events increasing due to changes in land use, increasing population, and climate change, characterizing wildfire emissions and their evolution is vital. In this work we report in situ airborne measurements of carbon dioxide (CO2), methane (CH4), water vapor (H2O), ozone (O3), and formaldehyde (HCHO) from nine wildfire events in California between 2013 and 2016, which were sampled as part of the Alpha Jet Atmospheric eXperiment (AJAX) based at NASA Ames Research Center. One of those fires, the Soberanes Megafire, began on 22 July 2016 and burned for three months. During that time, five flights were executed to sample emissions near and downwind of the Soberanes wildfire. In situ data are used to determine enhancement ratios (ERs), or excess mixing ratio relative to CO2, as well as assess O3 production from the fire. Changes in the emissions as a function of fire evolution are explored. Air quality impacts downwind of the fire are addressed using ground-based monitoring site data, satellite smoke products, and the Community Multiscale Air Quality (CMAQ) photochemical grid model.

Iraci, Laura T.↗

West Valley Demonstration Project (WVDP) Annual Site Environmental Report (ASER) for Calendar Year 2024

The report, prepared for the U.S. Department of Energy West Valley Demonstration Project office (DOE-WVDP), summarizes the environmental protection program at the WVDP for calendar year (CY) 2024. Monitoring and surveillance of the facilities used by the DOE are conducted to verify protection of public health and safety and the environment. The report is a key component of DOE’s effort to keep the public informed of environmental conditions at the WVDP. The quality assurance protocols applied to the environmental monitoring program ensure the validity and accuracy of the monitoring data. In addition to demonstrating compliance with environmental laws, regulations, and directives, evaluation of data collected in 2024 continued to indicate that WVDP activities pose no threat to public health or safety, or to the environment.

54 ENVIRONMENTAL SCIENCES↗

Quality Assurance Project Plan for Closure of the Central Facilities Area Sewage Treatment Plant Lagoon 3 and Land Application Area

This quality assurance project plan describes the technical requirements and quality assurance activities of the environmental data collection/analyses operations to close Central Facilities Area Sewage treatment Plant Lagoon 3 and the land application area. It describes the organization and persons involved, the data quality objectives, the analytical procedures, and the specific quality control measures to be employed. All quality assurance project plan activities are implemented to determine whether the results of the sampling and monitoring performed are of the right type, quantity, and quality to satisfy the requirements for closing Lagoon 3 and the land application area.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

An Architecture for Real-Time Interpretation and Visualization of Structural Sensor Data in a Laboratory Environment

A visualization system is being developed out of the need to monitor, interpret, and make decisions based on the information from several thousand sensors during experimental testing to facilitate development and validation of structural health monitoring algorithms. As an added benefit the system will enable complete real-time sensor assessment of complex test specimens. Complex structural specimens are routinely tested that have hundreds or thousands of sensors. During a test, it is impossible for a single researcher to effectively monitor all the sensors and subsequently interesting phenomena occur that are not recognized until post-test analysis. The ability to detect and alert the researcher to these unexpected phenomena as the test progresses will significantly enhance the understanding and utilization of complex test articles. Utilization is increased by the ability to halt a test when the health monitoring algorithm response is not satisfactory or when an unexpected phenomenon occurs, enabling focused investigation potentially through the installation of additional sensors. Often if the test continues, structural changes make it impossible to reproduce the conditions that exhibited the phenomena. The prohibitive time and costs associated with fabrication, sensoring, and subsequent testing of additional test articles generally makes it impossible to further investigate the phenomena. A scalable architecture is described to address the complex computational demands of structural health monitoring algorithm development and laboratory experimental test monitoring. The researcher monitors the test using a photographic quality 3D graphical model with actual sensor locations identified. In addition, researchers can quickly activate plots displaying time or load versus selected sensor response along with the expected values and predefined limits. The architecture has several key features. First, distributed dissimilar computers may be seamlessly integrated into the information flow. Second, virtual sensors may be defined that are complex functions of existing sensors or other virtual sensors. Virtual sensors represent a calculated value not directly measured by particular physical instrument. They can be used, for example, to represent the maximum difference in a range of sensors or the calculated buckling load based on the current strains. Third, the architecture enables autonomous response to preconceived events, where by the system can be configured to suspend or abort a test if a failure is detected in the load introduction system. Fourth, the architecture is designed to allow cooperative monitoring and control of the test progression from multiple stations both remote and local to the test system. To illustrate the architecture, a preliminary implementation is described monitoring the Stitched Composite Wing recently tested at LaRC.

Doggett, William↗