Search NASA⌕ Search

SEARCH · Search NASA

Results for “source characterization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,189 records · Page 66

Single-shot in-line x-ray phase-contrast imaging of void-shockwave interactions in fusion energy materials

Recent breakthroughs in nuclear fusion, specifically the report of reactions exceeding scientific breakeven at the National Ignition Facility (NIF), highlight the potential of inertial fusion energy (IFE) as a sustainable and virtually limitless energy source. However, further progress in IFE requires characterization of defects in ablator materials and how they affect fuel capsule compression. Voids within the ablator can degrade energy yield, but their impact on the density distribution has primarily been studied through simulations, with limited high-resolution experimental validation. To address this, we used the x-ray free-electron laser (XFEL) at the matter in extreme conditions (MECs) instrument at the Linac coherent light source (LCLS) to capture 2D x-ray phase-contrast (XPC) images of a void-bearing sample with a composition similar to inertial confinement fusion (ICF) ablators. By driving a compressive shockwave through the sample using MEC's long-pulse laser system, we analyzed how voids influence shockwave propagation and density distribution during compression. To quantify this impact, we extracted phase information using two phase retrieval algorithms. First, we applied the contrast transfer function (CTF) method, paired with Tikhonov regularization and a fast optimization approach to generate an initial phase estimate. We then refined the result using a projected gradient descent (PGD) method that works directly with the sample's refractive index. Comparing these results with radiation adaptive grid Eulerian (xRAGE) radiation hydrodynamic simulations enables identification of model validation needs or improvements. By calculating phase maps in situ, it becomes possible to reconstruct areal density maps, improving understanding of laser-capsule interactions and advancing IFE research.

Hodge, D. S. [Colorado State Univ., Fort Collins, ↗

Source position verification and dosimetry in HDR brachytherapy using an EPID

Purpose: Accurate treatment delivery in high dose rate (HDR) brachytherapy requires correct source dwell positions and dwell times to be administered relative to each other and to the surrounding anatomy. Treatment delivery inaccuracies predominantly occur for two reasons: (i) anatomical movement or (ii) as a result of human errors that are usually related to incorrect implementation of the planned treatment. Electronic portal imaging devices (EPIDs) were originally developed for patient position verification in external beam radiotherapy and their application has been extended to provide dosimetric information. The authors have characterized the response of an EPID for use with an {sup 192}Ir brachytherapy source to demonstrate its use as a verification device, providing both source position and dosimetric information.Methods: Characterization of the EPID response using an {sup 192}Ir brachytherapy source included investigations of reproducibility, linearity with dose rate, photon energy dependence, and charge build-up effects associated with exposure time and image acquisition time. Source position resolution in three dimensions was determined. To illustrate treatment verification, a simple treatment plan was delivered to a phantom and the measured EPID dose distribution compared with the planned dose.Results: The mean absolute source position error in the plane parallel to the EPID, for dwells measured at 50, 100, and 150 mm source to detector distances (SDD), was determined to be 0.26 mm. The resolution of the z coordinate (perpendicular distance from detector plane) is SDD dependent with 95% confidence intervals of ±0.1, ±0.5, and ±2.0 mm at SDDs of 50, 100, and 150 mm, respectively. The response of the EPID is highly linear to dose rate. The EPID exhibits an over-response to low energy incident photons and this nonlinearity is incorporated into the dose calibration procedure. A distance (spectral) dependent dose rate calibration procedure has been developed. The difference between measured and planned dose is less than 2% for 98.0% of pixels in a two-dimensional plane at an SDD of 100 mm.Conclusions: Our application of EPID dosimetry to HDR brachytherapy provides a quality assurance measure of the geometrical distribution of the delivered dose as well as the source positions, which is not possible with any current HDR brachytherapy verification system.

61 RADIATION PROTECTION AND DOSIMETRY↗

Secondary ion mass spectrometry: The application in the analysis of atmospheric particulate matter

Currently, considerable attention has been paid to atmospheric particulate matter (PM) investigation due to its importance in human health and global climate change. Surface characterization of PM is important since the chemical heterogeneity between the surface and bulk may vary its impact on the environment and human being. Secondary ion mass spectrometry (SIMS) is a surface technique with high surface sensitivity, capable of high spatial chemical imaging and depth profiling. Recent research shows that SIMS holds great potential in analyzing both surface and bulk chemical information of PM. In this review, we presented the working principal of SIMS in PM characterization, summarized recent applications in PM analysis from different sources, discussed its advantages and limitations, and proposed the future development of this technique with a perspective in environmental sciences.

aerosol↗

Combined analysis of HPK 3.1 LGADs using a proton beam, beta source, and probe station towards establishing high volume quality control

The upgrades of the CMS and ATLAS experiments for the high luminosity phase of the Large Hadron Collider will employ precision timing detectors based on Low Gain Avalanche Detectors (LGADs). We present a suite of results combining measurements from the Fermilab Test Beam Facility, a beta source telescope, and a probe station, allowing full characterization of the HPK type 3.1 production of LGAD prototypes developed for these detectors. We demonstrate that the LGAD response to high energy test beam particles is accurately reproduced with a beta source. Finally, we further establish that probe station measurements of the gain implant accurately predict the particle response and operating parameters of each sensor, and conclude that the uniformity of the gain implant in this production is sufficient to produce full-sized sensors for the ATLAS and CMS timing detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design, characterization, and performance of a hard x-ray transmission microscope at the National Synchrotron Light Source II 18-ID beamline

A transmission X-ray microscope (TXM) has been designed and commissioned at the 18-ID Fullfield X-ray Imaging (FXI) beamline at the National Synchrotron Light Source-II (NSLS-II). This instrument operates in the 5-11 keV range, and, with the current set of optics, is capable of 30 nm spatial resolution imaging, with a field of view (FOV) of about 40 microns. For absorption contrast, the minimum exposure time for a single projection image is about 20 ms and an entire 3D tomography data set can be acquired in under one minute. The system enables tomographic reconstructions with sub-50 nm spatial resolution without the use of markers on the sample or corrections for rotation run-outs.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Characterizing the plasma-induced thermal loads on a 200 kW light-ion helicon plasma source via infra-red thermography

The light-ion helicon plasma source of the Proto-MPEX linear plasma device has been recently upgraded to enable pulsed (0.5–1 s) operation up to 200 kW. The main objective of this work is to report on the plasma-induced surface heat fluxes incident on the helicon window during high power operation (60–150 kW net power) for the purpose of the design of the upcoming material plasma exposure eXperiment (MPEX). The IR imaging system and associated physics models for the extraction of surface heat fluxes are presented. Furthermore, experimental results demonstrate that the control of the plasma strike point via magnetic flux mapping and the use of dedicated limiters is effective at reducing the heat loads on the dielectric window. Moreover, it is found that the flux mapping must create a gap between the plasma and the dielectric window of at least the plasma radial decay length. Extrapolated to 200 kW net RF power, this mode of operation can reduce the power lost to the dielectric window by 33%. The results presented have direct application to the design of high-powered helicon plasma sources that operate in a steady state. Examples include linear divertor simulators such as MPEX, electric thrusters, negative ion sources for NBI and linear plasma–material interaction test stands.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Sequential x-ray diffraction topography at 1-BM x-ray optics testing beamline at the advanced photon source

We report progress on implementation and commissioning of sequential X-ray diffraction topography at 1-BM Optics Testing Beamline of the Advanced Photon Source to accommodate growing needs of strain characterization in diffractive crystal optics and other semiconductor single crystals. The setup enables evaluation of strain in single crystals in the nearly-nondispersive double-crystal geometry. Si asymmetric collimator crystals of different crystallographic orientations were designed, fabricated and characterized using in-house capabilities. Imaging the exit beam using digital area detectors permits rapid sequential acquisition of X-ray topographs at different angular positions on the rocking curve of a crystal under investigation. Results on sensitivity and spatial resolution are reported based on experiments with high-quality Si and diamond crystals. The new setup complements laboratory-based X-ray topography capabilities of the Optics group at the Advanced Photon Source.

43 PARTICLE ACCELERATORS↗

Flat Field Anomalies in an X-ray CCD Camera Measured Using a Manson X-ray Source

The Static X-ray Imager (SXI) is a diagnostic used at the National Ignition Facility (NIF) to measure the position of the X-rays produced by lasers hitting a gold foil target. The intensity distribution taken by the SXI camera during a NIF shot is used to determine how accurately NIF can aim laser beams. This is critical to proper NIF operation. Imagers are located at the top and the bottom of the NIF target chamber. The CCD chip is an X-ray sensitive silicon sensor, with a large format array (2k x 2k), 24 μm square pixels, and 15 μm thick. A multi-anode Manson X-ray source, operating up to 10kV and 10W, was used to characterize and calibrate the imagers. The output beam is heavily filtered to narrow the spectral beam width, giving a typical resolution E/ΔE≈10. The X-ray beam intensity was measured using an absolute photodiode that has accuracy better than 1% up to the Si K edge and better than 5% at higher energies. The X-ray beam provides full CCD illumination and is flat, within ±1% maximum to minimum. The spectral efficiency was measured at 10 energy bands ranging from 930 eV to 8470 eV. We observed an energy dependent pixel sensitivity variation that showed continuous change over a large portion of the CCD. The maximum sensitivity variation occurred at 8470 eV. The geometric pattern did not change at lower energies, but the maximum contrast decreased and was not observable below 4 keV. We were also able to observe debris, damage, and surface defects on the CCD chip. The Manson source is a powerful tool for characterizing the imaging errors of an X-ray CCD imager. These errors are quite different from those found in a visible CCD imager.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Approaching the Lower Temporal Limit of Laser‐Produced Plasma Sources for Table‐Top Soft X‐Ray NEXAFS Measurements

Abstract The increasing popularity of time‐resolved X‐ray absorption measurements for understanding dynamics in molecular and material systems has led to many advances in table‐top sources for pulsed X‐rays. We report on a table‐top laser‐produced plasma (LPP) source that can perform soft X‐ray (SXR), near‐edge X‐ray absorption fine structure (NEXAFS) measurements using a laser source with 23 ps pulse duration. The spectrometer's key specifications, such as brilliance, resolution, and stability, are characterized against the more commonly used longer‐pulse‐duration LPP sources. The 23 ps laser produced approximately an order of magnitude weaker SXR flux than the 8 ns laser for a higher power density due to the smaller total energy absorbed by the plasma. The increased repetition rate, as well as the use of a high line‐density X‐grating, and a self‐referencing scheme still allowed for NEXAFS measurements of Si 3 N 4 and TiO 2 thin films with 2.5 minute acquisition times, a resolving power of E/ΔE=424, and a signal‐to‐noise ratio of 100. It was observed that degradation of the gas jet nozzle led to long‐term instability of the source, which can be remediated using alternative nozzle designs. This work demonstrates the feasibility of achieving higher temporal resolution in future time‐resolved X‐ray absorption measurements using table‐top LPP sources.

Nimlos, Danika [Division of Chemistry and Chemical↗

Random quasi-phase-matching for pulse characterization from the near to the long wavelength infrared

Experiments requiring ultrafast laser pulses require a full characterization of the electric field to glean meaning from the experimental data. Such characterization typically requires a separate parametric optical process. As the central wavelength range of new sources continues to increase so too does the need for nonlinear crystals suited for characterizing these wavelengths. Here we report on the use of poly-crystalline zinc selenide as a universal nonlinear crystal in the frequency resolved optical gating characterization technique from the near to long-wavelength infrared. Due to its property of random quasi-phase-matching it’s capable of phase matching second-harmonic and sum-frequency generation of ultra-broadband pulses in the near and long wavelength infrared, while being crystal orientation independent. With the majority of ultra-fast laser sources being in this span of wavelengths, this work demonstrates a greatly simplified approach towards ultra-fast pulse characterization spanning from the near to the long-wavelength infrared. To our knowledge there is no single optical technique capable of such flexible capabilities.

Davis, Brandin (ORCID:0000000166964548)↗

{gamma}-MnS nano and micro architectures: Synthesis, characterization and optical properties

Highlights: {yields} In this article we have reported the formation of {gamma}-MnS nano/microcrystalline material by a novel proposed route. Na{sub 2}[Mn(HL){sub 2}(H{sub 2}O){sub 2}]; 1:2 (M:L) chelate complex was synthesized in the first step by our previously reported method. The chelate complex precursor was subsequently decomposed by alkaline solution of thiocarbamide, resulting formation of {gamma}-MnS crystals in situ. {yields} The effect of reaction time and surfactant have been observed and discussed. The materials were characterized for crystallanity and morphology by SEM, TEM, XRD, UV-Vis, PL spectra and the results are thoroughly discussed. {yields} {gamma}-MnS crystals were formed when metal complex was used as metal source whereas Mn{sub 3}O{sub 4} was the dominant product when MnSO{sub 4}.H{sub 2}O was used as metal source. {yields} We have also proposed a plausible formation mechanism based on experimental evidence, analyses and previous reports. {yields} Optical property of the material has also been discussed in the present article. -- Abstract: {gamma}-MnS nanocrystalline materials have been prepared by reaction of Na{sub 2}[Mn(HL){sub 2}(H{sub 2}O){sub 2}]; 1:2 (M:L) chelate complex with alkaline solution of thiocarbamide in aqueous solution phase. Effect of metal chelate complex, reaction time and surfactant sodium dodecyl sulfate; SDS on phase, morphology and size of the products have been investigated. The metal chelate complex was synthesized by reacting Mn(II) ions with eriochrome black T (NaH{sub 2}L) in alkaline medium. {gamma}-MnS crystals were formed when metal complex was used as metal source whereas Mn{sub 3}O{sub 4} was the dominant product when MnSO{sub 4}.H{sub 2}O was used as metal source. Materials thus formed having various morphologies were characterized by X-ray diffraction, scanning electron microscopy (SEM), transmission electron microscopy (TEM) to determine the crystallinity, phase, structure and morphology. The optical properties of the thus prepared samples were determined by UV-vis absorption spectra and photoluminescence spectra. A possible formation mechanism of crystals has been discussed in this article.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Fe line diagnostics of cataclysmic variables and galactic ridge X-ray emission

The properties of the Galactic Ridge X-ray Emission (GRXE) observed in the 2–10 keV band place fundamental constraints on various types of X-ray sources in the Milky Way. Although the primarily discrete origin of the emission is now well established, the responsible populations of these sources remain uncertain, especially at relatively low fluxes. To provide insights into this issue, we systematically characterize the Fe emission line properties of the candidate types of the sources in the solar neighborhood and compare them with those measured for the GRXE. Our source sample includes 6 symbiotic stars, 16 intermediate polars (IPs), 3 polars, 16 quiescent dwarf novae, and 4 active binaries (ABs); they are all observed with the Suzaku X-ray Observatory. The data of about one-fourth of these sources are analyzed for the first time. We find that the mean equivalent width (EW{sub 6.7}) of the 6.7 keV line and the mean 7.0/6.7 keV line ratio are 107 ± 16.0 eV and 0.71 ± 0.04 for IPs and 221 ± 135 eV and 0.44 ± 0.14 for polars, respectively, which are all substantially different from those (490 ± 15 eV and 0.2 ± 0.08) for the GRXE. Instead, the GRXE values are better agreed by the EW{sub 6.7} (438 ± 84.6 eV) and the ratio (0.27 ± 0.06) observed for the DNe. We further find that the EW{sub 6.7} is strongly correlated with the 2–10 keV luminosity of the DNe, which can be characterized by the relation EW{sub 6.7}=(438±95eV)(L/10{sup 31}ergs{sup −1}){sup (−0.31±0.15)}. Accounting for this correlation, the agreement can be improved further, especially when the contributions from other class sources to the GRXE are considered, which all have low EW{sub 6.7} values. We conclude that the GRXE mostly consists of typically faint but numerous DNe, plus ABs, while magnetic cataclysmic variables are probably mainly the high-flux representatives of the responsible populations and dominate the GRXE only in harder energy bands.

79 ASTRONOMY AND ASTROPHYSICS↗

Three-dimensional global fluid simulations of cylindrical magnetized plasmas

Plasma dynamics in cylindrical geometry, with many well diagnosed experiments in operation worldwide, is of fundamental interest. These linear machines can provide an unique testing ground for direct and detailed comparisons of numerical simulations of nonlinear plasma dynamics with experiments. Thus, it is possible to assess the reproductive and predictive capabilities of plasma simulations in unprecedented detail. Here, three-dimensional global fluid simulations of a cylindrical magnetized plasma are presented. This plasma is characterized by the existence of spatially localized sources and sinks. The traditional scale separation paradigm is not applied in the simulation model to account for the important evolution of the background profiles due to the dynamics of turbulent fluctuations. Furthermore, the fluid modeling of sheath boundary conditions, which determine the plasma conditions, are an important ingredient to the code presented here. The linear properties of the model equations are studied and are shown to agree well with experimental observations of linear drift modes. The fully nonlinear simulations are characterized by turbulent fluctuations, which are dominated by low mode numbers in the large radial pressure gradient region. In the far plasma edge, the fluctuations display an intermittent character due to convection within radially extended spatiotemporal potential fluctuations. This paper reports on the model and general code results, while the detailed comparison to a specific experiment is left to a follow-up paper.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

High average power, highly brilliant laser-produced plasma source for soft X-ray spectroscopy

In this work, a novel laser-produced plasma source is presented which delivers pulsed broadband soft X-radiation in the range between 100 and 1200 eV. The source was designed in view of long operating hours, high stability, and cost effectiveness. It relies on a rotating and translating metal target and achieves high stability through an on-line monitoring device using a four quadrant extreme ultraviolet diode in a pinhole camera arrangement. The source can be operated with three different laser pulse durations and various target materials and is equipped with two beamlines for simultaneous experiments. Characterization measurements are presented with special emphasis on the source position and emission stability of the source. As a first application, a near edge X-ray absorption fine structure measurement on a thin polyimide foil shows the potential of the source for soft X-ray spectroscopy.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High lifetime and mobility CdTe alloys by co-sublimation

The focus of this project was to understand controlled doping of CdTe and CdSe x Te 1-x films using group V element dopants such as nitrogen and arsenic. Using methods such as metal organic precursor injection as well as deposition of absorber with source charge incorporated with desired group V dopant. Using characterization methods such as Secondary Ion Mass Spectroscopy and capacitance vs voltage measurement dopant incorporation and activation was verified. Since our deposition system had CuCl deposition source, this source was permanently removed from the system and vacuum chamber was thoroughly cleaned out. CdSe x Te 1-x grading into CdTe has led to higher device efficiency owing to an improvement in short-circuit current (J SC ) due to its lower band-gap. More device fabrication and characterization was performed in an effort to optimize the lower band-gap CdSe x Te 1-x . This optimization was performed using different co-sublimation method where CdTe and Se were co-sublimated in varying proportion to sweep the band-gap of CdSe x Te 1-x that deposited on the substrate.

14 SOLAR ENERGY↗

Extragalactic Peaked-spectrum Radio Sources at Low Frequencies

We present a sample of 1483 sources that display spectral peaks between 72 MHz and 1.4 GHz, selected from the GaLactic and Extragalactic All-sky Murchison Widefield Array (GLEAM) survey. The GLEAM survey is the widest fractional bandwidth all-sky survey to date, ideal for identifying peaked-spectrum sources at low radio frequencies. Our peaked-spectrum sources are the low-frequency analogs of gigahertz-peaked spectrum (GPS) and compact-steep spectrum (CSS) sources, which have been hypothesized to be the precursors to massive radio galaxies. Our sample more than doubles the number of known peaked-spectrum candidates, and 95% of our sample have a newly characterized spectral peak. We highlight that some GPS sources peaking above 5 GHz have had multiple epochs of nuclear activity, and we demonstrate the possibility of identifying high-redshift ( z > 2) galaxies via steep optically thin spectral indices and low observed peak frequencies. The distribution of the optically thick spectral indices of our sample is consistent with past GPS/CSS samples but with a large dispersion, suggesting that the spectral peak is a product of an inhomogeneous environment that is individualistic. We find no dependence of observed peak frequency with redshift, consistent with the peaked-spectrum sample comprising both local CSS sources and high-redshift GPS sources. The 5 GHz luminosity distribution lacks the brightest GPS and CSS sources of previous samples, implying that a convolution of source evolution and redshift influences the type of peaked-spectrum sources identified below 1 GHz. Finally, we discuss sources with optically thick spectral indices that exceed the synchrotron self-absorption limit.

79 ASTRONOMY AND ASTROPHYSICS↗

A Small-Animal Irradiation Facility for Neutron Capture Therapy Research at the RA-3 Research Reactor

The National Atomic Energy Commission of Argentina (CNEA) has constructed a thermal neutron source for use in Boron Neutron Capture Therapy (BNCT) applications at the RA-3 research reactor facility located in Buenos Aires. The Idaho National Laboratory (INL) and CNEA have jointly conducted some initial neutronic characterization measurements for one particular configuration of this source. The RA-3 reactor (Figure 1) is an open pool type reactor, with 20% enriched uranium plate-type fuel and light water coolant. A graphite thermal column is situated on one side of the reactor as shown. A tunnel penetrating the graphite structure enables the insertion of samples while the reactor is in normal operation. Samples up to 14 cm height and 15 cm width are accommodated.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗