Search NASA⌕ Search

SEARCH · Search NASA

Results for “statistical image analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,189 records · Page 66

SU-D-9A-02: Relative Effects of Threshold Choice and Spatial Resolution Modeling On SUV and Volume Quantification in F18-FDG PET Imaging of Anal Cancer Patients

Purpose: PET imaging with F18-FDG is utilized for treatment planning, treatment assessment, and prognosis. A region of interest (ROI) encompassing the tumor may be determined on the PET image, often by a threshold T on the PET standard uptake values (SUVs). Several studies have shown prognostic value for relevant ROI properties including maximum SUV value (SUVmax), metabolic tumor volume (MTV), and total glycolytic activity (TGA). The choice of threshold T may affect mean SUV value (SUVmean), MTV, and TGA. Recently spatial resolution modeling (SRM) has been introduced on many PET systems. SRM may also affect these ROI properties. The purpose of this work is to investigate the relative influence of SRM and threshold choice T on SUVmean, MTV, TGA, and SUVmax. Methods: For 9 anal cancer patients, 18F-FDG PET scans were performed prior to treatment. PET images were reconstructed by 2 iterations of Ordered Subsets Expectation Maximization (OSEM), with and without SRM. ROI contours were generated by 5 different SUV threshold values T: 2.5, 3.0, 30%, 40%, and 50% of SUVmax. Paired-samples t tests were used to compare SUVmean, MTV, and TGA (a) for SRM on versus off and (b) between each pair of threshold values T. SUVmax was also compared for SRM on versus off. Results: For almost all (57/60) comparisons of 2 different threshold values, SUVmean, MTV, and TGA showed statistically significant variation. For comparison of SRM on versus off, there were no statistically significant changes in SUVmax and TGA, but there were statistically significant changes in MTV for T=2.5 and T=3.0 and in SUVmean for all T. Conclusion: The near-universal statistical significance of threshold choice T suggests that, regarding harmonization across sites, threshold choice may be a greater concern than choice of SRM. However, broader study is warranted, e.g. other iterations of OSEM should be considered.

60 APPLIED LIFE SCIENCES↗

The Laboratory for Oceans Computing Facility

The first VAX computer in the Laboratory for Oceans Computing Facility (LOCF) was installed and the facility was largely expanded. The growth is not only in hardware and software, but also in the number of users and in supporting research and development projects. The LOCF serves as a general purpose computing facility for: ocean color research projects, sea ice research projects, processing of the Nimbus-7 Coastal Zone Color Scanner data set, real time ingest and analysis of TIROS-N satellite data, study of the Synthetic Aperture Radar data, study of LANDSAT data, and many others. The physical space and the electrical power layout of the computing room were modified to accommodate all the equipment. The LOCF has several image processing stations which include two International Imaging Systems (IIS) model 75 processors and one Adage processor. The facility has the capability of ingesting the TIROS-N HRPT satellite data on a real time basis. More than 30 software packages were installed on the systems. System software packages, network software, FORTRAN and C compilers, database management software, image processing software, graphics, mathematics and statistics packages, TAE, Catalog Manager, GEMPAK, LAS and many other software developed on the LOCF computers such as SEAPAK have greatly advanced the capability of the LOCF.

Kao, R.↗

Mapping of the Ronda peridotite massif (Spain) from AVIRIS spectro-imaging survey: A first attempt

In both AVIRIS and ISM data, through the use of mixing models, geological boundaries of the Ronda massif are identified with respect to the surrounding rocks. We can also yield first-order vegetation maps. ISM and AVIRIS instruments give consistent results. On the basis of endmember fraction images, it is then possible to discard areas highly vegetated or not belonging to the peridotite massif. Within the remaining part of the mosaic, spectro-mixing analysis reveals spectral variations in the peridotite massif between the well-exposed areas. Spatially organized units are depicted, related to differences in the relative depth of the absorption band at 1 micron, and it may be due to a different pyroxene content. At this stage, it is worth noting that, although mineralogical variations observed in the rocks are at a sub-pixel scale for the airborne analysis, we see an emerging spatial pattern in the distribution of spectral variations across the massif which might be prevailingly related to mineralogy. Although it is known from fieldwork that the Ronda peridotite massif exhibits mineralogical variations at local scale in the content of pyroxene, and at regional scale in different mineral facies, ranging from garnet-, to spinel- to plagioclase-lherzolites, no attempt has been done yet to produce a synoptic map relating the two scales of analysis. The present work is a first attempt to reach this objective, though a lot more work is still required. In particular, for the purpose of mineralogical interpretation, it is critical to relate the airborne observation to field work and laboratory spectra of Ronda rocks already obtained, with the use of image endmembers and associated reference endmembers. Also, the pretty rough linear mixing model used here is taken as a 'black-box' process which does not necessarily apply correctly to the physical situation at the sub-pixel level. One may think of using the ground-truth observations bearing on the sub-pixel statistical characteristics (texture, structural pattern, surface distribution and vegetation contribution (grass,..)) to produce a more advanced mixing model, physically appropriate to the geologic and environmental contexts.

Pinet, P. C.↗

Observations of Small Debris from the Cosmos 1408 Anti-Satellite Test using the HUSIR and Goldstone Radars

On 15 November 2021, Russia conducted a direct-ascent anti-satellite (ASAT) test against its Cosmos 1408 satellite, which had been in orbit since 1982. The test produced at least 1500 fragments trackable by the U.S. Space Surveillance Network (SSN). The test is a significant event because the resulting cloud has the potential to endanger the International Space Station and other satellites in low Earth orbit (LEO). For almost 30 years, the NASA Orbital Debris Program Office (ODPO) has used the Haystack Ultrawideband Satellite Imaging Radar (HUSIR), operated by the Massachusetts Institute of Technology’s Lincoln Laboratory to perform statistical measurements of debris in LEO too small to be tracked by the SSN, nominally down to 5.5 mm at 1000 km altitude. The ODPO also utilizes the Goldstone Orbital Debris Radar (Goldstone), operated by NASA’s Jet Propulsion Laboratory, to characterize the small debris environment in LEO down to approximately 3 mm at 1000 km altitude. To characterize the small debris component of the Cosmos 1408 ASAT test, a series of observation campaigns were conducted with the HUSIR and Goldstone radars. This paper discusses the observation planning, including beam overlap analysis needed for Goldstone bistatic operation, using a model of the debris cloud produced with the NASA Standard Satellite Breakup Model. A description of the radars and the data processing techniques used to analyze the data are also discussed. Finally, results of the measurement campaigns including cumulative count rate versus size and surface area flux versus altitude and inclination are presented

James Murray↗

Liver segmentation in contrast enhanced CT data using graph cuts and interactive 3D segmentation refinement methods

Purpose: Liver segmentation is an important prerequisite for the assessment of liver cancer treatment options like tumor resection, image-guided radiation therapy (IGRT), radiofrequency ablation, etc. The purpose of this work was to evaluate a new approach for liver segmentation. Methods: A graph cuts segmentation method was combined with a three-dimensional virtual reality based segmentation refinement approach. The developed interactive segmentation system allowed the user to manipulate volume chunks and/or surfaces instead of 2D contours in cross-sectional images (i.e, slice-by-slice). The method was evaluated on twenty routinely acquired portal-phase contrast enhanced multislice computed tomography (CT) data sets. An independent reference was generated by utilizing a currently clinically utilized slice-by-slice segmentation method. After 1 h of introduction to the developed segmentation system, three experts were asked to segment all twenty data sets with the proposed method. Results: Compared to the independent standard, the relative volumetric segmentation overlap error averaged over all three experts and all twenty data sets was 3.74%. Liver segmentation required on average 16 min of user interaction per case. The calculated relative volumetric overlap errors were not found to be significantly different [analysis of variance (ANOVA) test, p = 0.82] between experts who utilized the proposed 3D system. In contrast, the time required by each expert for segmentation was found to be significantly different (ANOVA test, p = 0.0009). Major differences between generated segmentations and independent references were observed in areas were vessels enter or leave the liver and no accepted criteria for defining liver boundaries exist. In comparison, slice-by-slice based generation of the independent standard utilizing a live wire tool took 70.1 min on average. A standard 2D segmentation refinement approach applied to all twenty data sets required on average 38.2 min of user interaction and resulted in statistically not significantly different segmentation error indices (ANOVA test, significance level of 0.05). Conclusions: All three experts were able to produce liver segmentations with low error rates. User interaction time savings of up to 71% compared to a 2D refinement approach demonstrate the utility and potential of our approach. The system offers a range of different tools to manipulate segmentation results, and some users might benefit from a longer learning phase to develop efficient segmentation refinement strategies. The presented approach represents a generally applicable segmentation approach that can be applied to many medical image segmentation problems.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-J-79: Evaluation of Prostate Volume Changes During Radiotherapy Using Implanted Markers and On-Board Imaging

Purpose: To evaluate prostate volume changes during radiation therapy using implanted gold markers and on-board imaging. Methods: Twenty-five patients were included who underwent an implantation of three gold markers. Cartesian coordinates of markers were assessed in kV-images. The coordinates of centers of two markers were measured on kV-images from the center of the marker at the apex which was reference. The distances between the markers were extrapolated from the coordinates using the Euclid formula. The radius of the sphere through markers was calculated using sinus theorem. The prostate volume for the first and last fraction was substituted with a sphere model and was calculated for each patient. The t-test was used for analysis. Results: The mean prostate volume for first and last fraction was 24.65 and 20.87 cc, respectively (p≤0.05). The prostate volume was smaller for 23 patients, whereas there was an expansion for 2 patients. Fifteen patients had androgen deprivation during radiotherapy (H group) and ten did not (NH group). The mean prostate volume for the first and last fraction for the NH group was 30.73 cc and 24.89 cc and for the H group 20.84 cc and 18.19 cc, respectively. There was a 15.8% volume change during treatment for the NH group and 12.2% for the H group, but the difference was not statistically significant. The radius difference of the theoretical sphere for the first and last fraction was 0.98 mm (range, 0.09–2.95 mm) and remained below 2 mm in 88% of measurements. Conclusion: There was a significant volume change during prostate radiotherapy. The difference between H group and NH group was not significant. The radius changes did not exceed 3 mm and it was below adaptive treatment requirements. Our results indicate that prostate volume changes during treatment should be taken into account during contouring and treatment planning.

60 APPLIED LIFE SCIENCES↗

Remote Sensing of Tundra Ecosystems Using High Spectral Resolution Reflectance: Opportunities and Challenges

Abstract Observing the environment in the vast regions of Earth through remote sensing platforms provides the tools to measure ecological dynamics. The Arctic tundra biome, one of the largest inaccessible terrestrial biomes on Earth, requires remote sensing across multiple spatial and temporal scales, from towers to satellites, particularly those equipped for imaging spectroscopy (IS). We describe a rationale for using IS derived from advances in our understanding of Arctic tundra vegetation communities and their interaction with the environment. To best leverage ongoing and forthcoming IS resources, including National Aeronautics and Space Administration’s Surface Biology and Geology mission, we identify a series of opportunities and challenges based on intrinsic spectral dimensionality analysis and a review of current data and literature that illustrates the unique attributes of the Arctic tundra biome. These opportunities and challenges include thematic vegetation mapping, complicated by low‐stature plants and very fine‐scale surface composition heterogeneity; development of scalable algorithms for retrieval of canopy and leaf traits; nuanced variation in vegetation growth and composition that complicates detection of long‐term trends; and rapid phenological changes across brief growing seasons that may go undetected due to low revisit frequency or be obscured by snow cover and clouds. We recommend improvements to future field campaigns and satellite missions, advocating for research that combines multi‐scale spectroscopy, from lab studies to satellites that enable frequent and continuous long‐term monitoring, to inform statistical and biophysical approaches to model vegetation dynamics.

54 ENVIRONMENTAL SCIENCES↗

Constraining Lorentz Invariance Violation Using the Crab Pulsar Emission Observed up to TeV Energies by MAGIC

Spontaneous breaking of Lorentz symmetry at energies on the order of the Planck energy or lower is predicted by many quantum gravity theories, implying non-trivial dispersion relations for the photon in vacuum. Consequently, gamma-rays of different energies, emitted simultaneously from astrophysical sources, could accumulate measurable differences in their time of flight until they reach the Earth. Such tests have been carried out in the past using fast variations of gamma-ray flux from pulsars, and more recently from active galactic nuclei and gamma-ray bursts. We present new constraints studying the gamma-ray emission of the galactic Crab Pulsar, recently observed up to TeV energies by the Major Atmospheric Gamma-ray Imaging Cherenkov (MAGIC) collaboration. A profile likelihood analysis of pulsar events reconstructed for energies above 400 GeV finds no significant variation in arrival time as their energy increases. Ninety-five percent CL limits are obtained on the effective Lorentz invariance violating energy scale at the level of E{sub QG{sub 1}}>5.5×10{sup 17} GeV (4.5×10{sup 17} GeV) for a linear, and E{sub QG{sub 2}}>5.9×10{sup 10} GeV (5.3×10{sup 10} GeV) for a quadratic scenario, for the subluminal and the superluminal cases, respectively. A substantial part of this study is dedicated to calibration of the test statistic, with respect to bias and coverage properties. Moreover, the limits take into account systematic uncertainties, which are found to worsen the statistical limits by about 36%–42%. Our constraints would have been much more stringent if the intrinsic pulse shape of the pulsar between 200 GeV and 400 GeV was understood in sufficient detail and allowed inclusion of events well below 400 GeV.

79 ASTRONOMY AND ASTROPHYSICS↗

Quantitative NO{sub 2} molecular tagging velocimetry at 500 kHz frame rate

NO{sub 2} molecular tagging velocimetry (MTV) is demonstrated at repetition rates as high as 500 kHz in a laboratory scale Mach 5 wind tunnel. A pulse burst laser and a home built optical parametric oscillator system were used to simultaneously generate the required 355 and 226 nm wavelengths for NO{sub 2} photodissociation (tagging) and NO planar laser induced fluorescence imaging (interrogation), respectively. NO{sub 2} MTV images were obtained both in front and behind the characteristic bow shock from a 5 mm diameter cylinder. From Gaussian curve fitting, an average free stream flow velocity of 719 m/s was obtained. Absolute statistical precision in velocity of {approx}11.5 m/s was determined, corresponding to relative precision of 1.6%-5%, depending upon the region of the flow probed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A complete grain-level assessment of the stress-strain evolution and associated deformation response in polycrystalline alloys

Polycrystalline alloys are used pervasively across structural applications contingent upon extensive experimental testing. A statistically representative number of tests are required to expose the variability in the material's performance, as a result of non-uniform microstructures and associated micromechanical fields. In a more direct means of capturing this pertinent information, multi-modal experimental techniques are presented to measure and track the complete micromechanical state, evolving during loading, of each and every grain within the regions of interest. Specifically, a combination of high-energy X-ray diffraction microscopy and digital image correlation coupled with electron backscatter diffraction are conducted on a specimen for each of the alloys, Haynes 282 and Ti7Al. The results of the multi-modal analysis definitively demonstrate that the degree of heterogeneity increases with deformation level and is used to assess the number of grains necessary for a representative volume element description of the stress state for each of these materials. Moreover, higher resolution imaging is used for identification of the slip system activity and subsequently used to study slip transmission events. An accurate knowledge of the resolved shear stress in adjacent grains (grain interactions) is demonstrated to be a key descriptor of the slip transmission events.

36 MATERIALS SCIENCE↗

Monthly Oceanic Rainfall from TRMM Microwave Imager (TMI) Data

We evaluated the performance of the Tropical Rainfall Measuring Mission (TRMM) Microwave Imager (TMI) at-launch algorithm for monthly oceanic rain rate using two years (January 1998 - December 1999) of TMI data. The TMI at-launch algorithm is based on Wilheit et al.'s technique for estimating monthly oceanic rainfall that relies on histograms of multichannel microwave measurements. Comparisons with oceanic monthly rain rates derived from the Defense Meteorological Satellite Program (DMSP) F-13 and F-14 Special Sensor Microwave Imager (SSM/I) data show the average rain rates over the TRMM region (between 400S and 40N) are 3.0, 2.85 and 2.89 mm/day, respectively for F-13, F-14 and TMI. Based on the latest version of TB data (version 5), both rainrate and freezing height derived from TMI are similar to those from the F-13 and F-14 SSM/I data. However, regionally the differences are statistically significant at the 95% confidence. Three hourly monthly rainrates are also computed from 3-hourly TB histograms to examine the diurnal cycle of precipitation. Over most of the oceanic TRMM area, a distinct early morning rainfall peak is found. A harmonic analysis shows that the amplitude of the 12h harmonic is significant and comparable to that of the 24h harmonic.

Chang, Alfred T. C.↗

Arctic Tundra Vegetation Functional Types Based on Photosynthetic Physiology and Optical Properties

Climate change in tundra regions may alter vegetation species composition and ecosystem carbon balance. Remote sensing provides critical tools for monitoring these changes as optical signals provide a way to scale from plot measurements to regional patterns. Gas exchange measurements of pure patches of key vegetation functional types (lichens, mosses, and vascular plants) in sedge tundra at Barrow AK, show three significantly different values of light use efficiency (LUE) with values of 0.013+/-0.001, 0.0018+/-0.0002, and 0.0012 0.0001 mol C/mol absorbed quanta for vascular plants, mosses and lichens, respectively. Further, discriminant analysis of patch reflectance identifies five spectral bands that can separate each vegetation functional type as well as nongreen material (bare soil, standing water, and dead leaves). These results were tested along a 100 m transect where midsummer spectral reflectance and vegetation coverage were measured at one meter intervals. Area-averaged canopy LUE estimated from coverage fractions of the three functional types varied widely, even over short distances. Patch-level statistical discriminant functions applied to in situ hyperspectral reflectance successfully unmixed cover fractions of the vegetation functional types. These functions, developed from the tram data, were applied to 30 m spatial resolution Earth Observing-1 Hyperion imaging spectrometer data to examine regional variability in distribution of the vegetation functional types and from those distributions, the variability of LUE. Across the landscape, there was a fivefold variation in tundra LUE that was correlated to a spectral vegetation index developed to detect vegetation chlorophyll content.

Huemmrich, Karl F.↗

Simulating image coaddition with the Nancy Grace Roman Space Telescope – II. Analysis of the simulated images and implications for weak lensing

One challenge for applying current weak lensing analysis tools to the Nancy Grace Roman Space Telescope is that individual images will be undersampled. Our companion paper presented an initial application of Imcom – an algorithm that builds an optimal mapping from input to output pixels to reconstruct a fully sampled combined image – on the Roman image simulations. In this paper, we measure the output noise power spectra, identify the sources of the major features in the power spectra, and show that simple analytic models that ignore sampling effects underestimate the power spectra of the coadded noise images. We compute the moments of both idealized injected stars and fully simulated stars in the coadded images, and their one- and two-point statistics. We show that the idealized injected stars have root-mean-square ellipticity errors (1–6) × 10 -4 per component depending on the band; the correlation functions are ≥2 orders of magnitude below requirements, indicating that the image combination step itself is using a small fraction of the overall Roman second moment error budget, although the fourth moments are larger and warrant further investigation. The stars in the simulated sky images, which include blending and chromaticity effects, have correlation functions near the requirement level (and below the requirement level in a wide-band image constructed by stacking all four filters). We evaluate the noise-induced biases in the ellipticities of injected stars, and explain the resulting trends with an analytical model. We conclude by enumerating the next steps in developing an image coaddition pipeline for Roman.

79 ASTRONOMY AND ASTROPHYSICS↗

Use of ERTS data for a multidisciplinary analysis of Michigan resources

The author has identified the following significant results. The results of this investigation of ratioing simulated ERTS spectral bands and several non-ERTS bands (all collected by an airborne multispectral scanner) indicate that significant terrain information is available from band-ratio images. Ratio images, which are based on the relative spectral changes which occur from one band to another, are useful for enhancing differences and aiding the image interpreter in identifying and mapping the distribution of such terrain elements as seedling crops, all bare soil, organic soil, mineral soil, forest and woodlots, and marsh areas. In addition, the ratio technique may be useful for computer processing to obtain recognition images of large areas at lower costs than with statistical decision rules. The results of this study of ratio processing of aircraft MSS data will be useful for future processing and evaluation of ERTS-1 data for soil and landform studies. Additionally, the results of ratioing spectral bands other than those currently collected by ERTS-1 suggests that some other bands (particularly a thermal band) would be useful in future satellites.

Andersen, A. L.↗

Standardization of a Volumetric Displacement Measurement for Two-Body Abrasion Scratch Test Data Analysis

A limitation has been identified in the existing test standards used for making controlled, two-body abrasion scratch measurements based solely on the width of the resultant score on the surface of the material. A new, more robust method is proposed for analyzing a surface scratch that takes into account the full three-dimensional profile of the displaced material. To accomplish this, a set of four volume displacement metrics are systematically defined by normalizing the overall surface profile to statistically denote the area of relevance, termed the Zone of Interaction (ZOI). From this baseline, depth of the trough and height of the ploughed material are factored into the overall deformation assessment. Proof of concept data were collected and analyzed to demonstrate the performance of this proposed methodology. This technique takes advantage of advanced imaging capabilities that now allow resolution of the scratched surface to be quantified in greater detail than was previously achievable. A quantified understanding of fundamental particle-material interaction is critical to anticipating how well components can withstand prolonged use in highly abrasive environments, specifically for our intended applications on the surface of the Moon and other planets or asteroids, as well as in similarly demanding, harsh terrestrial settings

Kobrick, Ryan L.↗

Software and Algorithms for Biomedical Image Data Processing and Visualization

A new software equipped with novel image processing algorithms and graphical-user-interface (GUI) tools has been designed for automated analysis and processing of large amounts of biomedical image data. The software, called PlaqTrak, has been specifically used for analysis of plaque on teeth of patients. New algorithms have been developed and implemented to segment teeth of interest from surrounding gum, and a real-time image-based morphing procedure is used to automatically overlay a grid onto each segmented tooth. Pattern recognition methods are used to classify plaque from surrounding gum and enamel, while ignoring glare effects due to the reflection of camera light and ambient light from enamel regions. The PlaqTrak system integrates these components into a single software suite with an easy-to-use GUI (see Figure 1) that allows users to do an end-to-end run of a patient s record, including tooth segmentation of all teeth, grid morphing of each segmented tooth, and plaque classification of each tooth image. The automated and accurate processing of the captured images to segment each tooth [see Figure 2(a)] and then detect plaque on a tooth-by-tooth basis is a critical component of the PlaqTrak system to do clinical trials and analysis with minimal human intervention. These features offer distinct advantages over other competing systems that analyze groups of teeth or synthetic teeth. PlaqTrak divides each segmented tooth into eight regions using an advanced graphics morphing procedure [see results on a chipped tooth in Figure 2(b)], and a pattern recognition classifier is then used to locate plaque [red regions in Figure 2(d)] and enamel regions. The morphing allows analysis within regions of teeth, thereby facilitating detailed statistical analysis such as the amount of plaque present on the biting surfaces on teeth. This software system is applicable to a host of biomedical applications, such as cell analysis and life detection, or robotic applications, such as product inspection or assembly of parts in space and industry.

Talukder, Ashit↗

Global Precipitation Measurement (GPM) Mission Products and Services at the NASA Goddard Earth Sciences Data and Information Services Center (GES DISC)

The NASA Goddard Earth Sciences (GES) Data and Information Services Center (DISC) hosts and distributes GPM data within the NASA Earth Observation System Data Information System (EOSDIS). The GES DISC is also home to the data archive for the GPM predecessor, the Tropical Rainfall Measuring Mission (TRMM). Over the past 17 years, the GES DISC has served the scientific as well as other communities with TRMM data and user-friendly services. During the GPM era, the GES DISC will continue to provide user-friendly data services and customer support to users around the world. GPM products currently and to-be available: -Level-1 GPM Microwave Imager (GMI) and partner radiometer products, DPR products -Level-2 Goddard Profiling Algorithm (GPROF) GMI and partner products, DPR products -Level-3 daily and monthly products, DPR products -Integrated Multi-satellitE Retrievals for GPM (IMERG) products (early, late, and final) A dedicated Web portal (including user guides, etc.) has been developed for GPM data (http://disc.sci.gsfc.nasa.gov/gpm). Data services that are currently and to-be available include Google-like Mirador (http://mirador.gsfc.nasa.gov/) for data search and access; data access through various Web services (e.g., OPeNDAP, GDS, WMS, WCS); conversion into various formats (e.g., netCDF, HDF, KML (for Google Earth), ASCII); exploration, visualization, and statistical online analysis through Giovanni (http://giovanni.gsfc.nasa.gov); generation of value-added products; parameter and spatial subsetting; time aggregation; regridding; data version control and provenance; documentation; science support for proper data usage, FAQ, help desk; monitoring services (e.g. Current Conditions) for applications. The United User Interface (UUI) is the next step in the evolution of the GES DISC web site. It attempts to provide seamless access to data, information and services through a single interface without sending the user to different applications or URLs (e.g., search, access, subset, Giovanni, documents).

precipitation↗

TU-H-CAMPUS-IeP1-01: Bias and Computational Efficiency of Variance Reduction Methods for the Monte Carlo Simulation of Imaging Detectors

Purpose: Variance reduction techniques (VRTs) are employed in Monte Carlo simulations to obtain estimates with reduced statistical uncertainty for a given simulation time. In this work, we study the bias and efficiency of a VRT for estimating the response of imaging detectors. Methods: We implemented Directed Sampling (DS), preferentially directing a fraction of emitted optical photons directly towards the detector by altering the isotropic model. The weight of each optical photon is appropriately modified to maintain simulation estimates unbiased. We use a Monte Carlo tool called fastDETECT2 (part of the hybridMANTIS open-source package) for optical transport, modified for VRT. The weight of each photon is calculated as the ratio of original probability (no VRT) and the new probability for a particular direction. For our analysis of bias and efficiency, we use pulse height spectra, point response functions, and Swank factors. We obtain results for a variety of cases including analog (no VRT, isotropic distribution), and DS with 0.2 and 0.8 optical photons directed towards the sensor plane. We used 10,000, 25-keV primaries. Results: The Swank factor for all cases in our simplified model converged fast (within the first 100 primaries) to a stable value of 0.9. The root mean square error per pixel for DS VRT for the point response function between analog and VRT cases was approximately 5e-4. Conclusion: Our preliminary results suggest that DS VRT does not affect the estimate of the mean for the Swank factor. Our findings indicate that it may be possible to design VRTs for imaging detector simulations to increase computational efficiency without introducing bias.

60 APPLIED LIFE SCIENCES↗