Search NASA⌕ Search

SEARCH · Search NASA

Results for “threshold based”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,189 records · Page 66

Proposed Rectal Dose Constraints for Patients Undergoing Definitive Whole Pelvic Radiotherapy for Clinically Localized Prostate Cancer

Purpose: Although several institutions have reported rectal dose constraints according to threshold toxicity, the plethora of trials has resulted in multiple, confusing dose-volume histogram recommendations. A set of standardized, literature-based constraints for patients undergoing whole pelvic radiotherapy (RT) for prostate cancer would help guide the practice of prostate RT. The purpose of this study was to develop these constraints, demonstrate that they are achievable, and assess the corresponding rectal toxicity. Methods and Materials: An extensive literature search identified eight key studies relating dose-volume histogram data to rectal toxicity. A correction factor was developed to address differences in the anatomic definition of the rectum across studies. The dose-volume histogram constraints recommended by each study were combined to generate the constraints. The data from all patients treated with definitive intensity-modulated RT were then compared against these constraints. Acute rectal toxicity was assessed. Results: A continuous, proposed rectal dose-constraint curve was generated. Intensity-modulated RT not only met this constraint curve, but also was able to achieve at least 30-40% lower dose to the rectum. The preliminary clinical results were also positive: 50% of patients reported no acute bowel toxicity, 33% reported Grade 1 toxicity, and 17% reported Grade 2 toxicity. No patients reported Grade 3-4 acute rectal toxicity. Conclusions: In this study, we developed a set of proposed rectal dose constraints. This allowed for volumetric assessment of the dose-volume relationship compared with single dose-volume histogram points. Additional research will be performed to validate this threshold as a class solution for rectal dose constraints.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Temperature-Dependent Transport Characteristics of 2D MoS2 Channel FETs Grown Using Salt-Based Precursors

D Transition Metal Dichalcogenides (TMDs), particularly MoS2, are promising candidates for sub-10 nm Gate All Around (GAA) CMOS FETs. Salt-assisted Chemical Vapor Deposition (CVD) enable lateral MoS2 growth at atmospheric pressure and low temperatures. This work analyzes salt-based precursor-driven CVD-grown MoS2 FETs at various temperatures. MoS2 was grown using Ammonium Molybdate salt, sulfurized at 750∘C, and transferred onto p−Si3/SiO2 substrates. At room temperature, threshold voltage (VT) ranged from -35 V to -25 V, with a peak drain current of 1.2μA/μm. As temperature increased above 325K, VT shifted exponentially, and carrier mobility dropped significantly. At 400 K, the gate lost channel control, though gate leakage current remained low. These results are compared with non-salt-based MoS2 growth to assess salt precursor effects.Notice: This manuscript has been authored by UT-Battelle, LLC, under contract DE-AC05-00OR22725 with the US Department of Energy (DOE). The US government retains and the publisher, by accepting the article for publication, acknowledges that the US government retains a nonexclusive, paid-up, irrevocable, worldwide license to publish or reproduce the published form of this manuscript, or allow others to do so, for US government purposes. DOE will provide public access to these results of federally sponsored research in accordance with the DOE Public Access Plan (https://www.energy.gov/doe-public-access-plan).

Jones, Andrew [ORNL] (ORCID:0009000233849687)↗

Photoionization of two-electron atoms via highly doubly excited states: Numerical and semiclassical results

The quantum regime of highly doubly excited states in two-electron atoms has, so far, been largely inaccessible both to numerical methods as well as to experiments. Recent advances in semiclassical closed orbit theory in combination with a quantum mapping approach have shown a new way into this region of high dynamical complexity. In particular, new scaling laws near the double-ionization threshold as well as the dominant semiclassical contributions to the total photoionization cross section can be identified. We will present this new approach here in all its detail. It is based on representing the photoionization cross section in terms of quantum maps. These quantum maps or quantum propagators are used as a starting point for developing an efficient numerical method for calculating cross sections. Furthermore, by writing the quantum operators in semiclassical approximations, it is possible to interpret the quantum results in terms of classical triple collision orbits and to derive threshold laws near the three-particle breakup point. Semiclassical and numerical quantum results show excellent agreement for a model system, namely collinear helium.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Memristive Ion Channel-Doped Biomembranes as Synaptic Mimics

Solid-state neuromorphic systems based on transistors or memristors have yet to achieve the interconnectivity, performance, and energy efficiency of the brain due to excessive noise, undesirable material properties, and nonbiological switching mechanisms. Here in this work, we demonstrate that an alamethicin-doped, synthetic biomembrane exhibits memristive behavior, emulates key synaptic functions including paired-pulse facilitation and depression, and enables learning and computing. Unlike state-of-the-art devices, our two-terminal, biomolecular memristor features similar structure (biomembrane), switching mechanism (ion channels), and ionic transport modality as biological synapses while operating at considerably lower power. The reversible and volatile voltage-driven insertion of alamethicin peptides into an insulating lipid bilayer creates conductive pathways that exhibit pinched current–voltage hysteresis at potentials above their insertion threshold. Moreover, the synapse-like dynamic properties of the biomolecular memristor allow for simplified learning circuit implementations. Finally, low-power memristive devices based on stimuli-responsive biomolecules represent a major advance toward implementation of full synaptic functionality in neuromorphic hardware.

36 MATERIALS SCIENCE↗

Investigation of negative bias temperature instability dependence on fin width of silicon-on-insulator-fin-based field effect transistors

The fin width dependence of negative bias temperature instability (NBTI) of double-gate, fin-based p-type Field Effect Transistors (FinFETs) fabricated on silicon-on-insulator (SOI) wafers was investigated. The NBTI degradation increased as the fin width narrowed. To investigate this phenomenon, simulations of pre-stress conditions were employed to determine any differences in gate oxide field, fin band bending, and electric field profile as a function of the fin width. The simulation results were similar at a given gate stress bias, regardless of the fin width, although the threshold voltage was found to increase with decreasing fin width. Thus, the NBTI fin width dependence could not be explained from the pre-stress conditions. Different physics-based degradation models were evaluated using specific fin-based device structures with different biasing schemes to ascertain an appropriate model that best explains the measured NBTI dependence. A plausible cause is an accumulation of electrons that tunnel from the gate during stress into the floating SOI fin body. As the fin narrows, the sidewall device channel moves in closer proximity to the stored electrons, thereby inducing more band bending at the fin/dielectric interface, resulting in a higher electric field and hole concentration in this region during stress, which leads to more degradation. The data obtained in this work provide direct experimental proof of the effect of electron accumulation on the threshold voltage stability in FinFETs.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Quantum physics of stars

Stars are slowly developing objects; the lifetimes of the different burning phases are determined by the strength of nuclear reactions, which in turn are defined by the quantum structure of the associated nuclei at the threshold and the respective reaction mechanisms. Stars, from the nuclear physics perspective, are cold environments where only a few of the key nuclear reactions have been measured at the actual stellar plasma temperatures. This is also the case for more dynamic astrophysical phenomena from the big bang to stellar explosions. Most of the nuclear reaction rates are therefore based on theoretical extrapolations. A number of discrepancies between these predictions and the associated stellar signatures have been observed, and many may be due to low-energy or near-threshold quantum effects. These effects need to be understood in order to reliably model nuclear reaction processes, not only for stars but also for low-temperature plasma environments such as controlled magnetic or inertial confinement fusion systems, which operate in similar temperature regimes. This review summarizes the various theoretical techniques presently used for deriving reaction rates and discusses possible quantum effects that may impact the reaction cross section near the reaction threshold. These resemble enhanced single-particle and cluster structures near threshold and associated interference effects. New experimental techniques such as deep-underground accelerators or the study of transfer reactions to mimic the quantum-mechanical transition strength, the so-called Trojan horse method, provide ways to directly or indirectly probe the reaction features that determine the reaction rates at stellar energies. Furthermore, this is demonstrated on a number of key nuclear reactions for different nucleosynthesis environments. Finally, current inconsistencies between experimental predictions and observations are discussed.

Models & methods for nuclear reactions↗

SU-E-T-647: Quality Assurance of VMAT by Gamma Analysis Dependence On Low-Dose Threshold

Purpose: The AAPM TG-119 instructed institutions to use low-dose threshold (LDT) of 10% or a ROI determined by the jaw when they collected gamma analysis QA data of planar dose distribution. Also, based on a survey by Nelms and Simon, more than 70% of institutions use a LDT between 0% and 10% for gamma analysis. However, there are no clinical data to quantitatively demonstrate the impact of the LDT on the gamma index. Therefore, we performed a gamma analysis with LDTs of 0% to 15% according to both global and local normalization and different acceptance criteria: 3%/3 mm, 2%/2 mm, and 1%/1 mm. Methods: A total of 30 treatment plans—10 head and neck, 10 brain, and 10 prostate cancer cases—were randomly selected from the Varian Eclipse TPS, retrospectively. For the gamma analysis, a predicted portal image was acquired through a portal dose calculation algorithm in the Eclipse TPS, and a measured portal image was obtained using a Varian Clinac iX and an EPID. Then, the gamma analysis was performed using the Portal Dosimetry software. Results: For the global normalization, the gamma passing rate (%GP) decreased as the LDT increased, and all cases of low-dose thresholds exhibited a %GP above 95% for both the 3%/3 mm and 2%/2 mm criteria. However, for local normalization, the %GP increased as LDT increased. The gamma passing rate with LDT of 10% increased by 6.86%, 9.22% and 6.14% compared with the 0% in the case of the head and neck, brain and prostate for 3%/3 mm criteria, respectively. Conclusion: Applying the LDT in the global normalization does not have critical impact to judge patient-specific QA results. However, LDT for the local normalization should be carefully selected because applying the LDT could affect the average of the %GP to increase rapidly.

61 RADIATION PROTECTION AND DOSIMETRY↗

Extraction of the Brain from CT Head Scans Based on Domain Knowledge

We present an automatic approach for an efficient brain extraction from CT head scans. Regions of interest are first set in each slice by applying thresholding and region growing. Next, the brain candidates are extracted by using three-dimensional region growing with a variable, anatomy-dependent structuring element. Domain knowledge, including Hounsfield unit ranges, anatomy, and image acquisition parameters, is applied. The proposed method has been applied automatically to 27 CT normal and pathological scans and has shown promising results. The average sensitivity, specificity and Dice's index for 5 cases are 99.6%, 99.4% and 98.7%, respectively.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Exponential Escape Rate of Filamentary Incubation in Mott Spiking Neurons

Mott materials such as vanadium oxides, when subject to a strong applied voltage, present an inhomogeneous insulator-to-metal transition with formation of metallic filaments within the insulating bulk. This property is enabling the development of compact and power-efficient neuromorphic devices known as Mott neurons. However, the nature of the transition has not been fully understood yet, as it may be attributed to different effects, including Joule self-heating and hot-carrier injection. Moreover, the experimental determination of the threshold voltage needed to induce the transition has proven to be challenging, as the transition becomes increasingly unpredictable when the threshold is approached. The physical understanding of these issues would not only deepen our understanding of Mott insulators, but would also be an important step toward the realization of neuromorphic devices based on such materials. In this work we use numerical simulations based on the Mott resistor network model to study the nature of the filament incubation and formation process. Here, we show that both electronic and thermal effects, in the form of current density focusing and Joule self-heating, respectively, contribute to the filamentary incubation and growth. Remarkably, we find that the percolation of the metallic filaments near the threshold is intrinsically stochastic, qualitatively similar to the familiar Arrhenius activated behavior and to the stochastic firing of biological neurons. More precisely, we characterize the filament percolation as a Poisson point process, which has the same probability distribution as mathematical models of neuronal firing with an exponential escape rate. Finally, we support the numerical simulation results by performing experiments in VO 2 that are in agreement with the exponential escape rate behavior. Thus, we establish a functionality of Mott insulators that opens a path toward implementing neuromorphic hardware with quantum materials.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Automation and optimization of stopping and range of ions in matter simulation runtime

Prior to every ion implantation experiment a simulation of the ion range and other relevant parameters is performed using Monte-Carlo based codes. Although increasing computing power has improved the speed of these calculations, the demands on Monte-Carlo codes are also increasing, requiring evaluation of the optimal number of simulations while ensuring accuracy within threshold bounds. We evaluate the “Stopping and Range of Ions in Matter” (SRIM) code due to its widespread usage. We show how dividing simulations into multiple parallel simulations with different random seeds can lead to calculation speedup and find lower bounds for the required number of ion traces simulated based on an exemplar system of a Ga focused ion beam and a high energy C beam as used in high linear energy transfer testing. Here our results indicate simulations can yield results within the underlying data accuracy of SRIM at 10X and 100X shorter simulation time than the SRIM default values.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Wavelength Scaling of High-Harmonic Yield: Threshold Phenomena and Bound State Symmetry Dependence

Describing harmonic generation (HG) in terms of a system's complex quasienergy, the harmonic power P{sub {delta}}{sub E}({lambda}) (over a fixed interval, {delta}E, of harmonic energies) is shown to reproduce the wavelength scaling predicted recently by two groups of authors based on solutions of the time-dependent Schroedinger equation: P{sub {delta}}{sub E}({lambda}){approx}{lambda}{sup -x}, where x{approx_equal}5-6. Oscillations of P{sub {delta}}{sub E}({lambda}) on a fine {lambda} scale are then shown to have a quantum origin, involving threshold phenomena within a system of interacting ionization and HG channels, and to be sensitive to the bound state wave function's symmetry.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Optimizing the accuracy of a helical diode array dosimeter: A comprehensive calibration methodology coupled with a novel virtual inclinometer

Purpose: The goal of any dosimeter is to be as accurate as possible when measuring absolute dose to compare with calculated dose. This limits the uncertainties associated with the dosimeter itself and allows the task of dose QA to focus on detecting errors in the treatment planning (TPS) and/or delivery systems. This work introduces enhancements to the measurement accuracy of a 3D dosimeter comprised of a helical plane of diodes in a volumetric phantom. Methods: We describe the methods and derivations of new corrections that account for repetition rate dependence, intrinsic relative sensitivity per diode, field size dependence based on the dynamic field size determination, and positional correction. Required and described is an accurate ''virtual inclinometer'' algorithm. The system allows for calibrating the array directly against an ion chamber signal collected with high angular resolution. These enhancements are quantitatively validated using several strategies including ion chamber measurements taken using a ''blank'' plastic shell mimicking the actual phantom, and comparison to high resolution dose calculations for a variety of fields: static, simple arcs, and VMAT. A number of sophisticated treatment planning algorithms were benchmarked against ion chamber measurements for their ability to handle a large air cavity in the phantom. Results: Each calibration correction is quantified and presented vs its independent variable(s). The virtual inclinometer is validated by direct comparison to the gantry angle vs time data from machine log files. The effects of the calibration are quantified and improvements are seen in the dose agreement with the ion chamber reference measurements and with the TPS calculations. These improved agreements are a result of removing prior limitations and assumptions in the calibration methodology. Average gamma analysis passing rates for VMAT plans based on the AAPM TG-119 report are 98.4 and 93.3% for the 3%/3 mm and 2%/2 mm dose-error/distance to agreement threshold criteria, respectively, with the global dose-error normalization. With the local dose-error normalization, the average passing rates are reduced to 94.6 and 85.7% for the 3%/3 mm and 2%/2 mm criteria, respectively. Some algorithms in the convolution/superposition family are not sufficiently accurate in predicting the exit dose in the presence of a 15 cm diameter air cavity. Conclusions: Introduction of the improved calibration methodology, enabled by a robust virtual inclinometer algorithm, improves the accuracy of the dosimeter's absolute dose measurements. With our treatment planning and delivery chain, gamma analysis passing rates for the VMAT plans based on the AAPM TG-119 report are expected to be above 91% and average at about 95% level for {gamma}(3%/3 mm) with the local dose-error normalization. This stringent comparison methodology is more indicative of the true VMAT system commissioning accuracy compared to the often quoted dose-error normalization to a single high value.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Topology optimization under uncertainty via non-intrusive polynomial chaos expansion

This paper presents a systematic approach for topology optimization under uncertainty that integrates non-intrusive polynomial chaos expansion with design sensitivity analysis for reliability-based and robust topology optimization. Uncertainty is introduced in loading and in geometry to address the manufacturing variability. The manufacturing variability is modeled via a thresholding technique in which the threshold field is represented by a reduced dimensional random field. Response metrics such as compliance and volume are characterized as polynomial chaos expansions of the underlying uncertain parameters thus allowing accurate and efficient estimation of statistical moments, failure probabilities and their sensitivities. The number of simulations is reduced for linear structures under loading uncertainty by means of superposition. Efficiency of the non-intrusive polynomial chaos approach is highlighted by comparison with the Monte Carlo method in terms of the number of simulations. To demonstrate the effect of uncertainty, optimized designs that consider uncertainty are compared to those that do not. Finally, comparisons of polynomial chaos expansion to existing analytical methods on a benchmark numerical example are also provided for reliability-based and worst case designs.

42 ENGINEERING↗

An optimization of the FPGA trigger based on the artificial neural network for a detection of neutrino-origin showers

Observations of ultra-high energy neutrinos became a priority in experimental astro-particle physics. Up to now, the Pierre Auger Observatory did not find any candidate on a neutrino event. This imposes competitive limits to the diffuse flux of ultra-high energy neutrinos in the EeV range and above. A very low rate of events potentially generated by neutrinos is a significant challenge for a detection technique and requires both sophisticated algorithms and high-resolution hardware. A trigger based on a artificial neural network was implemented into the Cyclone{sup R} V E FPGA 5CEFA9F31I7. The prototype Front-End boards for Auger-Beyond-2015 with Cyclone{sup R} V E can test the neural network algorithm in real pampas conditions in 2015. Showers for muon and tau neutrino initiating particles on various altitudes, angles and energies were simulated in CORSICA and Offline platforms giving pattern of ADC traces in Auger water Cherenkov detectors. The 3-layer 12-10-1 neural network was taught in MATLAB by simulated ADC traces according the Levenberg-Marquardt algorithm. Results show that a probability of a ADC traces generation is very low due to a small neutrino cross-section. Nevertheless, ADC traces, if occur, for 1-10 EeV showers are relatively short and can be analyzed by 16-point input algorithm. For 100 EeV range traces are much longer, but with significantly higher amplitudes, which can be detected by standard threshold algorithms. We optimized the coefficients from MATLAB to get a maximal range of potentially registered events and for fixed-point FPGA processing to minimize calculation errors. Currently used Front-End boards based on no-more produced ACEXR PLDs and obsolete Cyclone{sup R} FPGAs allow an implementation of relatively simple threshold algorithms for triggers. New sophisticated trigger implemented in Cyclone{sup R} V E FPGAs with large amount of DSP blocks, embedded memory running with 120 - 160 MHz sampling may support to discover neutrino events in the Pierre Auger Observatory. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-J-72: Dosimetric Study of Cone-Beam CT-Based Radiation Treatment Planning Using a Patient-Specific Stepwise CT-Density Table

Purpose: To assess dose calculation accuracy of cone-beam CT (CBCT) based treatment plans using a patient-specific stepwise CT-density conversion table in comparison to conventional CT-based treatment plans. Methods: Unlike CT-based treatment planning which use fixed CT-density table, this study used patient-specific CT-density table to minimize the errors in reconstructed mass densities due to the effects of CBCT Hounsfield unit (HU) uncertainties. The patient-specific CT-density table was a stepwise function which maps HUs to only 6 classes of materials with different mass densities: air (0.00121g/cm3), lung (0.26g/cm3), adipose (0.95g/cm3), tissue (1.05 g/cm3), cartilage/bone (1.6g/cm3), and other (3g/cm3). HU thresholds to define different materials were adjusted for each CBCT via best match with the known tissue types in these images. Dose distributions were compared between CT-based plans and CBCT-based plans (IMRT/VMAT) for four types of treatment sites: head and neck (HN), lung, pancreas, and pelvis. For dosimetric comparison, PTV mean dose in both plans were compared. A gamma analysis was also performed to directly compare dosimetry in the two plans. Results: Compared to CT-based plans, the differences for PTV mean dose were 0.1% for pelvis, 1.1% for pancreas, 1.8% for lung, and −2.5% for HN in CBCT-based plans. The gamma passing rate was 99.8% for pelvis, 99.6% for pancreas, and 99.3% for lung with 3%/3mm criteria, and 80.5% for head and neck with 5%/3mm criteria. Different dosimetry accuracy level was observed: 1% for pelvis, 3% for lung and pancreas, and 5% for head and neck. Conclusion: By converting CBCT data to 6 classes of materials for dose calculation, 3% of dose calculation accuracy can be achieved for anatomical sites studied here, except HN which had a 5% accuracy. CBCT-based treatment planning using a patient-specific stepwise CT-density table can facilitate the evaluation of dosimetry changes resulting from variation in patient anatomy.

60 APPLIED LIFE SCIENCES↗

Analysis of coupled-bunch instabilities for the NSLS-II storage ring with a 500MHz 7-cell PETRA-III cavity

The NSLS-II storage ring is designed to operate with superconducting RF-cavities with the aim to store an average current of 500 mA distributed in 1080 bunches, with a gap in the uniform filling for ion clearing. At the early stage of the commissioning (phase 1), characterized by a bare lattice without damping wigglers and without Landau cavities, a normal conducting 7-cell PETRA-III RF-cavity structure has been installed with the goal to store an average current of 25 mA. In this paper we discuss our analysis of coupled-bunch instabilities driven by the Higher Order Modes (HOMs) of the 7-cell PETRA-III RF-cavity. As a cure of the instabilities, we apply a well-known scheme based on a proper detuning of the HOMs frequencies based upon cavity temperature change, and the use of the beneficial effect of the slow head–tail damping at positive chromaticity to increase the transverse coupled-bunch instability thresholds. In addition, we discuss measurements of coupled-bunch instabilities observed during the phase 1 commissioning of the NSLS-II storage ring. In our analysis we rely, in the longitudinal case, on the theory of coupled-bunch instability for uniform fillings, while in the transverse case we complement our studies with numerical simulations with OASIS, a novel parallel particle tracking code for self-consistent simulations of collective effects driven by short and long-range wakefields.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Using Falcon to develop an RIA PCMI failure criteria

This paper documents the development of failure criteria for both pressurized water reactor (PWR) and boiling water reactor (BWR) fuel rod failure due to pellet cladding mechanical interaction (PCMI) during a reactivity insertion accident (RIA). This study was initiated to use cladding mechanical properties using data from separate effects tests to provide a basis to translate nuclear safety research reactor (NSRR) test data to commercial light water reactor conditions. The approach employed for the revised licensing criteria combined elements of experimental results and analytical evaluations to develop a fundamental understanding of fuel behavior during RIA events. The transient behavior of intermediate and high burnup fuel rods using well characterized RIA simulation tests was established. Cladding mechanical properties using data from separate effects tests was also developed. The Zircaloy cladding mechanical properties database of separate effects tests was used to develop the cladding integrity models. The cladding integrity models were then used in combination with the application of the Falcon fuel behavior code to translate NSRR test data to commercial light water reactor conditions. Because of the complex manner in which burnup influences fuel rod failure, it was not possible to develop a fuel rod failure threshold directly from the experimental data. An alternative approach was required that combined analytical modeling and experimental data to develop the PCMI-related contribution to the failure threshold. The analytical approach computed the radial average peak fuel enthalpy required to cause cladding failure by PCMI as a function of hydrogen content. This was accomplished by applying a critical strain energy density (CSED)-based cladding integrity model using data from total and uniform elongation tests of irradiated low-tin Zircaloy-4, ZIRLO, and Zircaloy-2 cladding materials. The CSED was developed as a function of cladding hydrogen content because hydrogen induced embrittlement is a primary effect of burnup. It was found that the failure threshold decreased with hydrogen content due to the increase in PCMI loading as a result of gap closure effects and by the decrease in cladding ductility with hydrogen accumulation. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

WE-H-BRC-03: Failure Mode and Effects Analysis in the First Clinical Implementation of a Novel Stereotactic Breast Radiotherapy Device: GammaPod™

Purpose: GammaPod™, the first stereotactic radiotherapy device for early stage breast cancer treatment, has been recently installed and commissioned at our institution. A multidisciplinary working group applied the failure mode and effects analysis (FMEA) approach to perform a risk analysis. Methods: FMEA was applied to the GammaPod™ treatment process by: 1) generating process maps for each stage of treatment; 2) identifying potential failure modes and outlining their causes and effects; 3) scoring the potential failure modes using the risk priority number (RPN) system based on the product of severity, frequency of occurrence, and detectability (ranging 1–10). An RPN of higher than 150 was set as the threshold for minimal concern of risk. For these high-risk failure modes, potential quality assurance procedures and risk control techniques have been proposed. A new set of severity, occurrence, and detectability values were re-assessed in presence of the suggested mitigation strategies. Results: In the single-day image-and-treat workflow, 19, 22, and 27 sub-processes were identified for the stages of simulation, treatment planning, and delivery processes, respectively. During the simulation stage, 38 potential failure modes were found and scored, in terms of RPN, in the range of 9-392. 34 potential failure modes were analyzed in treatment planning with a score range of 16-200. For the treatment delivery stage, 47 potential failure modes were found with an RPN score range of 16-392. The most critical failure modes consisted of breast-cup pressure loss and incorrect target localization due to patient upper-body alignment inaccuracies. The final RPN score of these failure modes based on recommended actions were assessed to be below 150. Conclusion: FMEA risk analysis technique was applied to the treatment process of GammaPod™, a new stereotactic radiotherapy technology. Application of systematic risk analysis methods is projected to lead to improved quality of GammaPod™ treatments. Ying Niu and Cedric Yu are affiliated with Xcision Medical Systems.

60 APPLIED LIFE SCIENCES↗