Search NASASearch

SEARCH · Search NASA

Results for “75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND SUPERFLUIDITY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

1,693 records · Page 67

Storing Affordability: Battery Storage as an Asset to Reduce Data Center Cost Shifts

This report examines how battery energy storage systems (BESS) can help utilities accommodate large load growth while protecting affordability for existing ratepayers. Rapid growth in electricity demand from artificial intelligence (AI) data centers is straining the U.S. grid. Furthermore, many new data centers are entering rural markets, which could offer economic benefits but may also pose implementation challenges for smaller utilities. At the same time, retail electricity prices are increasing faster than inflation, elevating customer affordability as a key challenge. While data centers have not been the primary driver of increases in residential prices to date, they have pushed wholesale energy and capacity prices higher in several markets. Fundamental utility cost-allocation principles show that data center growth can be rate-positive for existing customers only if new peak demand grows faster than the costs a utility must incur to serve it. Several factors, including a utility’s degree of wholesale market exposure, forecast uncertainty and stranded-asset risk, and tariff design can determine the outcome of load growth on retail rates. Energy storage can make several affordability contributions in the face of this landscape of uncertainty and market volatility, including deferral of higher-cost grid investments through improved utilization of existing assets and flexibility of new large loads, insulation from volatile wholesale prices through peak shaving, and reliability support to address grid risks stemming from the behavior of AI data center loads. Different potential BESS deployment pathways—utility-scale front-of-the-meter systems, aggregated small-scale storage installations, and data center-sited behind-the-meter storage—are compared against each other and against conventional capacity alternatives. This framework is intended as a conceptual resource to utilities, particularly smaller public utilities with rural service territories, who may be considering the role that energy storage can play in insulating existing ratepayers from data center cost shifts.

25 ENERGY STORAGE

Carbon Tetrachloride Degradation Results for 200-ZP-1 Operable Unit

Carbon tetrachloride (CT) contamination in the 200-ZP-1 Operable Unit (OU) at the Hanford Site originated from large-volume discharges to the subsurface during plutonium production operations between 1955 and 1973. Contamination migrated through more than 70 meters of unsaturated sediment to reach the underlying unconfined aquifer, where it persists as a large and complex groundwater plume. The 200-ZP-1 OU Record of Decision (ROD) requires that groundwater CT concentrations be reduced to 3.4 µg/L within 125 years. Current groundwater modeling projections estimate that the existing pump-and-treat, even when combined with monitored natural attenuation (specifically hydrolysis), will not achieve this target within the designated timeframe. A fundamental contributor to this shortfall is the extremely slow rate of CT hydrolysis under Hanford aquifer conditions, which has been estimated to have a half-life of 630 years. If faster-acting biotic and abiotic degradation processes are operating within the aquifer, their contribution to CT mass reduction could have a meaningful impact. However, site-specific measurements of these processes and their rates have not previously been performed. This report documents the results of a two-phase laboratory investigation designed to characterize and quantify the capacity of site-specific 200-ZP-1 OU sediments and groundwater to support natural attenuation of CT through biotic and abiotic pathways. In this context, degradation capacity is defined as the intrinsic potential of the subsurface matrix to transform CT under optimized, controlled conditions. System capacity is evaluated in two ways: (1) as rate-limited capacity, which establishes the maximum kinetic velocity of CT transformation and is measured using half-lives and first order rate constants; and (2) as mass limited capacity, which defines the total contaminant mass the batch experimental system can degrade before reactants are exhausted, representing the maximum amount of contaminant the microbial community and reactive mineral phases can transform under the experimental conditions.

abiotic degradation

Supervisory genset control in range-extended electric vehicle

A controls system for a range-extended electric vehicle comprising an overall system control unit, an engine control module configured to control a range extender of the range-extended electric vehicle, power electronics configured to control a generator of the range-extended electric vehicle, and a supervisory control module coupled between the overall system control unit and the engine control module and the power electronics, the supervisory control module configured to receive information from the overall system control unit and provide commands to the engine control module and the power electronics.

Li, Ke

Analysis of an irradiated uranium sample for source attribution without chemical separation using microplasma ionization and ultrahigh resolution mass spectrometry

The use of element isotope ratios has great potential in not only determining the reactor type used to produce plutonium (Pu) but also in determining the burnup and the time since irradiation. While a powerful nuclear forensic technique, determining element isotope ratios is complicated by severe isobaric interferences when performed on typical inductively coupled plasma mass spectrometers. Such analyses require extensive chemical separations prior to analysis to alleviate the inter-elemental isobars. Ultrahigh mass resolution spectrometry provides a potential alternative, greatly reducing the complexity of sample preparation and turnaround times for these critical measurements. To demonstrate the power of the approach, a sample of irradiated, depleted uranium was analyzed with the liquid sampling—atmospheric pressure glow discharge ion source coupled to an Orbitrap mass spectrometer. The Orbitrap is augmented with an external data acquisition system, Spectroswiss’s FTMS-Booster X2T, allowing collection of extended ion transients, providing higher mass resolution. In using this approach, the 150 Sm/ 149 Sm and 152 Sm/ 149 Sm isotope ratios were found to be within 20% of predicted values without any chemical separations and without mass bias corrections. In addition, the 240 Pu/ 239 Pu isotope ratio was determined, free from the 238 UH + interferences common to the ICP-MS platforms, while at the same time allowing for the determination of U isotopic signatures. While these demonstrative results are from a single sample, the advantages of the microplasma/ultrahigh mass resolution approach to intra-element isotope ratio determinations are clear.

Fuel burnup

SAVY-4000 Finite-Element Drop Test Analysis

PFE Auxiliary Systems conducted drop testing on SAVY-4000 containers to evaluate structural response under 12-foot drop conditions. In support of that effort, a finite-element modeling capability was developed to simulate drop response across multiple container sizes and impact orientations. The purpose of this work was to provide a consistent analysis framework that could support interpretation of testing, compare response trends across multiple configurations, and generate quantities of interest for later comparison with experimental data. More broadly, the analysis and testing were intended to assess whether the containers continued to perform their primary function after a 12-foot drop, namely maintaining structural integrity and containment of the contents. The modeling approach combined an implicit preload analysis with an explicit drop simulation so that each drop event began from a mechanically realistic assembled condition, including compression of the silicone O-ring. Separate models were developed for 2-quart, 5-quart, 12-quart, and 10-gallon containers. The results were evaluated in terms of strain-gauge response, collar-lid gap behavior, and accumulated plastic strain. In addition, parametric studies were performed on the 2-quart container to assess sensitivity to O-ring stiffness, friction, canister thickness, geometry tolerance, and mesh density. The simulations showed that predicted drop responses depended strongly on both container size and drop orientation. Gap metrics identified cases in which the predicted collar-lid opening exceeded the nominal O-ring cross-section threshold, while plastic strain metrics identified localized regions of elevated permanent deformation. Parametric studies showed that the predicted response was especially sensitive to the assumed O-ring stiffness and contact friction, while the geometry tolerance study produced smaller changes in the cases examined. The main value of this work was that it established a repeatable modeling and simulation workflow to support drop-test implementation, evaluate effects of future configuration changes, and understand modeling assumptions that most influenced predicted response. At the current stage, the results were viewed as preliminary model predictions rather than validated predictions. The next step would be to compare drop-test data to the model so that predictive values of the workflow could be refined and used with greater confidence to assess whether the containers maintained structural integrity and containment of the contents after a 12-foot drop.

42 ENGINEERING

A Novel Approach to Investigate Thermal Protection Systems Materials

The Koo Research Group (KRG) at The University of Texas at Austin (UT) and KAI has specialized in “Ablation Research” for more than fifteen years. Recently, the group has developed several incredibly unique capabilities that can advance “Thermal Protection Systems (TPS) Materials Research & Development” using an integrated experimental and numerical approach. The paper aims to introduce the methodology KRG has developed to solve this challenging problem. It will discuss how the KRG develops “Process-Properties-Performance” relationships of novel TPS materials in a systematical approach using (a) processing and fabrication, (b) thermal characterization of properties, (c) aerothermal testing, (d) microstructures characterization and analysis, and (e) numerical modeling. Progress and challenges of this research will also be discussed.

Engineering

AutoSourceID-Classifier: Star-galaxy classification using a convolutional neural network with spatial information

Aims.Traditional star-galaxy classification techniques often rely on feature estimation from catalogs, a process susceptible to introducing inaccuracies, thereby potentially jeopardizing the classification’s reliability. Certain galaxies, especially those not manifesting as extended sources, can be misclassified when their shape parameters and flux solely drive the inference. We aim to create a robust and accurate classification network for identifying stars and galaxies directly from astronomical images. Methods.The AutoSourceID-Classifier (ASID-C) algorithm developed for this work uses 32x32 pixel single filter band source cutouts generated by the previously developed AutoSourceID-Light (ASID-L) code. By leveraging convolutional neural networks (CNN) and additional information about the source position within the full-field image, ASID-C aims to accurately classify all stars and galaxies within a survey. Subsequently, we employed a modified Platt scaling calibration for the output of the CNN, ensuring that the derived probabilities were effectively calibrated, delivering precise and reliable results. Results.We show that ASID-C, trained on MeerLICHT telescope images and using the Dark Energy Camera Legacy Survey (DECaLS) morphological classification, is a robust classifier and outperforms similar codes such as SourceExtractor. To facilitate a rigorous comparison, we also trained an eXtreme Gradient Boosting (XGBoost) model on tabular features extracted by SourceExtractor. While this XGBoost model approaches ASID-C in performance metrics, it does not offer the computational efficiency and reduced error propagation inherent in ASID-C’s direct image-based classification approach. ASID-C excels in low signal-to-noise ratio and crowded scenarios, potentially aiding in transient host identification and advancing deep-sky astronomy.

Astronomy & Astrophysics

Pressure Safety Training (Rev. 8)

This is the workbook for the Pressure Safety Training Course. It is intended as a reference manual and guide for all work with pressurized liquids or gases. This workbook contains basic references to make work with pressure safer. It is intended to supplement classroom instruction, rather than serve as a definitive text on pressure. Earlier versions of the manual were intended specifically for training at Lawrence Livermore National Laboratory. This revision is a generic version intended for training at all DOE facilities. The information in the Standards chapter is from the LLNL Health and Safety Manual. It is included here as a convenient reference and guide for developing similar standards at your own facility.

42 ENGINEERING

Cully Community Solar

This report summarizes the outcomes, accomplishments, challenges, and lessons learned from Verde’s Cully Community Solar project, funded by the U.S. Department of Energy’s Solar Energy Technologies Office. The project focused on advancing community solar development through engineering, permitting, interconnection, ecological site design, workforce development, and community engagement. During the project period, Verde and its partners successfully developed and commissioned a 1.25 MW ground-mounted community solar system while also advancing planning for additional community solar capacity and developing approaches that can inform future projects in complex urban environments.

14 SOLAR ENERGY

Acute Exposure to Aerosolized Nanoplastics Modulates Redox-Linked Immune Responses in Human Airway Epithelium

Micro- and nanoplastics (MPs and NPs) are pervasive environmental pollutants detected in aquatic ecosystems, with emerging evidence suggesting their presence in airborne particles generated by water body motion. Inhalation exposure to airborne MPs and NPs remains understudied despite documented links between occupational exposure to these particles and adverse respiratory outcomes, including airway inflammation, oxidative stress, and chronic respiratory diseases. This study explored the effects of acute NP exposure on a fully differentiated 3D human airway epithelial model derived from 14 healthy donors. Airway epithelium was exposed to aerosolized 50 nm polystyrene NPs at concentrations ranging from 2.5 to 2500 µg/mL for three minutes per day over three days. Functional assays revealed no significant alterations in tissue integrity, cell survival, mucociliary clearance, or cilia beat frequency, suggesting intact epithelial function post-exposure. However, cytokine and chemokine profiling identified a significant five-fold increase in CCL3 (MIP-1α), a neutrophilic chemoattractant, in NP-exposed samples compared to controls. This was corroborated by increased neutrophil chemotaxis in response to conditioned media from NP-exposed tissues, indicating a pro-inflammatory neutrophilic response. Conversely, levels of interleukins (IL-21, IL-2, IL-15), CXCL10, and TGF-β were significantly reduced, suggesting immunomodulatory effects that may impair adaptive immune responses and tissue repair mechanisms. These findings demonstrate that short-term exposure to NP-containing aerosols induces a distinct pro-inflammatory response in airway epithelium, characterized by enhanced neutrophil recruitment and reduced secretion of key immune modulators. These findings underscore the potential for aerosolized NPs to induce oxidative and inflammatory stress, raising concerns about their long-term impact on respiratory health and redox regulation.

Biochemistry & Molecular Biology

Field Validation of Thermoelectric Generation System at Holcim Cement Plant in Alpena, Michigan

Executive Summary Project Background The Industrial Technology Validation (ITV) program aims to identify and demonstrate the performance of new, emerging, and underutilized energy-saving technologies in the industrial sector to help inform decisions to help accelerate their commercialization and deployment, as well as to help make industries more competitive. This ITV demonstration evaluated a thermoelectric generation (TEG) technology at a cement plant, aiming to reduce energy demand in the cement industry. A median cement plant consumes 5.73 million British thermal units per ton of clinker production (resulting in 0.838 metric tons of carbon dioxide [CO₂] emissions per ton of clinker) (Boyd and Zhang 2011, EPA 2021), equivalent to approximately 6.9 trillion British thermal units (TBtu) per year in energy consumption at a cement plant producing 3,300 tons of clinker per day.¹ Collaborating with Holcim, Advanced Thermovoltaic Systems (ATS) developed and deployed a pilot-scale thermoelectric power system to efficiently capture and convert waste heat to electricity. The system leverages the Seebeck effect to convert temperature differences on two sides of semiconductor cartridges into electrical power (ScienceDirect, n.d.). This generation is realized with minimal moving parts compared to existing waste-heat-to-generation solutions and allows capture from heat sources with temperatures as low as 150°C. This project aimed to validate a scalable solution applicable for capturing medium-temperature waste heat, including ambient losses from other high-temperature processes, and high-temperature sources less suitable for other waste-heat-to-power solutions. By recovering this otherwise wasted heat, this project intends to validate improvements to overall process efficiency through reduction in purchased electricity, thereby reducing operational costs while enhancing resiliency and competitiveness. Description and Scope This study evaluated the performance of a TEG system from ATS as a solution to convert waste heat into useful power at a Holcim cement plant in Alpena, Michigan. This plant is a fully integrated cement plant that has been operating since 1907. The facility operates continuously (24/7/365) with approximately 250 employees and five long dry kilns, yielding a total production capacity of 7,852 tons of cement per day (EPA 2023). Currently, the Alpena plant uses waste heat boilers to convert waste heat from the exhaust of each kiln into steam, which drives steam turbine generators. The ATS TEG is being evaluated for its potential to supplement the steam turbines by capturing the remaining lower grade heat. This technology is also being considered for other Holcim plants where steam turbines are not a viable option. ATS installed a pilot-scale TEG unit with an array of 582 individual thermoelectric semiconductor cartridges, of which 573 were operational. The cartridges are sandwiched between 48 hot plates and 49 cold plates. Each cartridge is designed to generate 20 watts (W) of gross power at a hot-side temperature of 240°C and cold-side temperature of 20°C. As such, the total gross generation capacity of the installed system is 11.5 kilowatts (kW) at design conditions. The system configuration for the evaluation was designed to prioritize convenience of installation and minimize disruption to production at the site, while ensuring that the heat required can be obtained for evaluating the TEG system at various operational conditions. To accomplish this, a portion of the steam supplied to Alpena’s steam turbine generation system was diverted to be used as the heat source for the TEG system, while water was supplied to the cold side of the system from nearby Lake Huron. This configuration was designed for the evaluation of the pilot-scale system to assess the performance at different conditions. A commercial-scale system will likely vary from the pilot system depending on typical configurations, including both scale and application. Future commercial applications of the ATS system would involve integrating the system into the exhaust from kiln preheaters, clinker coolers, or radiant heat capture from kiln shells for the heat source. For the cold source, a range of cooling solutions can be considered, including a mechanical cooling system, depending on the location and the application. To increase the generation capacity for commercial applications, the technology provider is working toward developing a commercial-scale TEG system, which would combine multiple TEG units (each similar in design to the pilot system) together. The scope of this evaluation includes the pilot-scale TEG system and all impacted equipment including pumps, controllers, and power handling equipment. Study Objectives The evaluation's goal was to assess the potential of the ATS TEG system to generate useful electrical power by capturing waste heat from cement production kilns. The objectives of this study are to evaluate and verify the following claims made by ATS regarding the pilot-scale system installed at the Holcim Alpena plant. The following design parameters and claims are also outlined in Table ES- 1 and Table ES- 2: • Gross Power: The thermoelectric system converts heat into power to create gross power, the total measured power generated by the system. The 573 active cartridge pilot-scale system is expected to generate 11.5 kW of gross power at the designed hot-side temperature of 240°C and cold-side temperature of 20°C. Power production is dependent on the temperature difference between the heat source (ultimately from the waste heat) and cold temperature supply source. • Net Power: The net power is the total usable power provided to the site by the TEG system after deducting parasitic power loads from the gross generated power. Supplementary equipment is required to operate the TEG system including pumps, controllers, and, in certain anticipated applications, mechanical cooling, which introduce parasitic loads to system operation. After deducting the parasitic loads from the gross power generation, ATS anticipates achieving a net power generation of 7.5 kW from the pilot-scale system. • Thermal Efficiency: The thermal efficiency is the percent of the total heat transferred to the TEG system that is converted to gross power. Historically, TEGs have a thermal efficiency of 2%–5% (DOE 2008). Prior industrial-scale TEG systems, such as the E1 TEG offered by Alphabet Energy, operated at an efficiency of 2.5% (Lamonica, 2014). ATS anticipates achieving an average efficiency of 4.8% or higher in converting heat energy to usable electricity. • Cartridge Performance: The TEG system comprises 573 active individual semiconductor cartridges, each of which generates a portion of the total power. Cartridge optimization and selection is an important design consideration for potential future TEG system design performance. Therefore, understanding the distribution of gross power and efficiency within the pilot system is vital to understanding what is achievable. At a design hot-side temperature of 240°C and cold-side temperature of 20°C, ATS anticipates a cartridge performance of 20 W of gross power per cartridge at an efficiency of 4.8% per cartridge. In addition to evaluating the claimed performance of the TEG pilot-scale unit, the study estimated the potential annual impacts of a scaled-up commercial system used to capture kiln waste heat over annual operations. The evaluation estimated the gross and net annual electric generation achievable by capturing heat from the two proposed tap-in points: the kiln exhaust and the clinker cooler exhaust; see Section 2.1 for details. Two use cases were examined: • Holcim Alpena: The Holcim Alpena site consists of long dry kilns with superheater boilers, which differs from the rest of Holcim’s cement plant portfolio and results in lower waste heat temperatures. The study estimates gross and net annual generation using the superheater boiler exhaust and clinker cooler exhaust, based on 2023 operational data. • Typical Installation: Common cement plants have preheater kilns with higher exhaust temperatures than Holcim Alpena across a range of production rates. The study estimates gross and net annual generation using the preheater exhaust and clinker cooler exhaust, with a sensitivity analysis to account for the typical range of preheater exhaust temperatures, clinker cooler exhaust temperatures, and clinker production rates. Methodology The evaluation methodology followed a measurement and verification (M&V) strategy based on the International Performance Measurement and Verification Protocol Option B through comprehensive measurements and analyses of the affected systems. Evaluation data was collected from March 9 to March 11, 2024, the test period of the pilot TEG system. During the test period, in coordination with the ITV team, the ATS team adjusted system operations to capture the range of variability expected for each of the variables pertinent to performance of the system. The methodology consisted of two parts: evaluating the performance of the pilot unit's TEG system and estimating the annual TEG impact in terms of gross and net power based on a given waste heat profile. First, the evaluation of the thermoelectric generation performance of the pilot unit relative to the claims was performed by analyzing the collected test data. Gross power of the pilot TEG system was directly measured. Net power was determined by deducting the measured parasitic power from the gross power. The gross power generation was compared to heat transferred to the system by the working fluid (which was heated by steam generated from the kiln waste heat) to calculate the thermal efficiency achieved by the system. Performance of individual semiconductor cartridges within the pilot array was also assessed in terms of measured gross cartridge power and calculated cartridge thermal efficiency. The second part of the evaluation estimated the annual TEG impacts in terms of gross power and net power (calculated from the difference between gross power and parasitic power). This analysis comprised development of mathematical regression models for gross power and parasitic power, with assessment of each model’s goodness-of-fit characteristics to ensure satisfaction of statistical requirements. The models predicted the gross power generation, the parasitic load based on the temperature difference between the hot working fluid and the cold-side fluid (cold water from Lake Huron) entering the system, the volumetric flow rate of the cold-side fluid at the inlet, and the volumetric flow rate of the hot working fluid at the inlet. The annual impact analysis considered a theoretical commercial-scale system sized to capture the available waste heat at a cement plant, consisting of linked pilot-scale units that receive heat from a theoretical gas-to-working-fluid heat exchanger. To estimate annual impacts at the Alpena plant, the gross power and parasitic power regression models were applied to the arrays in the theoretical commercial-scale system. The heat supplied to the unit was calculated based on the kiln run time, annual production, kiln exhaust waste heat, and clinker cooler waste heat derived from 2023 Holcim Alpena kiln operational data. Net power impacts were calculated by deducting the resulting parasitic power from the estimated gross power. Inputs for the model were generated from a combination of hourly data, assumed design considerations for TEG system scale-up from the pilot-scale unit, and assumptions regarding TEG system operations. This analysis was then used as the basis for estimating annual impacts of typical TEG installation at cement plants, by applying sensitivity analyses to key kiln operational characteristics including kiln preheater exhaust temperatures, cooler clinker exhaust temperatures, and plant daily production rates across a range of expected values. Project Results/Findings Table ES- 2 and Table ES- 2 provide a summary of the operating conditions and evaluation results compared to the stated claims from the technology provider. Key takeaways include: • Gross Power: The peak gross power achieved during the testing period was 10.0 kW, compared to the 11.5 kW expected for 573 active cartridges. The claimed gross power was associated with a target hot side of 240°C; however, the system only received a maximum hot-side mean plate temperature of 212°C during the testing period. • Net Power: The pilot-scale unit exceeded the claims for net power, achieving a peak of 7.7 kW net compared to a claim of 7.5 kW. One factor contributing to the higher achieved net power is the relatively high water pressure available through Lake Huron. The pilot TEG system did not require cold-side pumps during the test, whereas most installations would. This reduced the parasitic loads on the system, ultimately contributing to higher net power relative to the gross power. • Thermal Efficiency: The pilot-scale unit outperformed the claimed efficiency, achieving a peak system efficiency of 5.0% thermal efficiency compared to the stated 4.8%. • Cartridge Performance: To compare cartridge performance against claims, the study focused on the third day of testing, which aimed for conditions closest to the design specifications, with a hot side of 240°C and cold-side exit temperature of 6.4°–30°C. On this day, the mean gross power observed in the cartridges within the TEG array was 18.1 W/cartridge, and the peak performance was 34.7 W/cartridge. The estimated mean cartridge efficiency was 5.2%, and the estimated efficiency at peak gross cartridge power was 10%. The regression models developed for gross power generation and parasitic loads were used to estimate the generation impact for given heat input to the TEG from the working fluid (captured from the waste heat) and from the cold loop (Lake Huron) on an hourly basis for a year of operation. Based on this analysis, installation of a commercial-scale TEG system at the Holcim cement plant in Alpena, Michigan, with a waste heat exchanger of 0.85 effectiveness, would generate up to 391 kW of net power, translating to between 920,000 and 1,800,000 kilowatt-hours (kWh) in net electricity per year. Based on typical grid emissions for Alpena, this would avoid estimated net emissions by 752 metric tons of CO₂ annually.² The sensitivity analysis estimated that typical TEG system installations at cement plants could generate an average of 56–1,040 kW of net power, or between 488,000 and 9,110,000 kWh of net energy. This generation potential is most significantly affected by plant production rates and also influenced by preheater and clinker cooler exhaust temperatures. Applying the national average emission rate, typical commercial-scale installations at Holcim plants are projected to avoid between 182 and 3,401 metric tons of CO₂ annually per site. Table ES- 3 shows a summary of the estimated annual impacts.³ While parasitic loads are significant and vary by application, this analysis assumed the use of heating loop pumps and access to Lake Huron as a cold sink. This setup assumed no need for cooling loop pumps due to the available water pressure at the test site. Applications that require cooling towers or additional equipment are likely to experience higher parasitic loads. Therefore, the study’s estimates are most applicable to scenarios with similar parasitic load configurations—namely, access to a high-pressure cold sink. Applicability to other locations may be limited, as differing conditions could necessitate additional pumps and cooling systems, potentially impacting performance significantly.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

Development of Hydrogen Burner for FT4000® Aeroderivative Engine - Final Report

This report details an effort to develop a retrofittable fuel/air injector for the FT4000® aeroderivative gas turbine that enables use of hydrogen as a carbon-free fuel for efficient power generation. The FT4000 engine’s low-NOx combustor was developed by Pratt & Whitney and RTX Technology Research Center with core technology from the Pratt & Whitney PW4000 turbofan aircraft engine. The current FT4000 production engine operates on either natural gas or No. 2 fuel oil with water injection to achieve high thermal efficiency and low emissions. This engine is fielded by Mitsubishi Power Aero and delivers 70 MW of power with a simple-cycle efficiency of over 41% when operating with wet compression. The work reported here advances the technology readiness level of the FT4000 combustor for operation with hydrogen, starting with an experimental assessment of the current production hardware with increasing hydrogen content mixed with natural gas and ending with improved nozzle concepts for fully robust operation with 100% hydrogen. High-pressure single-sector combustor rig tests have been completed, demonstrating the ability for the dual fuel nozzle to operate an FT4000 combustor on 100% hydrogen with low nitrogen oxide (NOx) emissions. Metal temperature measurements and video images of the flame structure from zero to 100% hydrogen highlight opportunities to improve the fuel nozzle robustness for high hydrogen conditions. The design of new fuel/air mixer concepts to improve durability and operability with high hydrogen levels was also completed. A total of eleven new concepts were developed and analyzed, ranging from modifications to the bill-of-materials nozzle to fully clean sheet designs. The concepts were evaluated with non-reacting and reacting flow evaluations to assess the performance of the new hardware designs. Non-reacting tests included Phase Doppler Particle Analysis (PDPA) for droplet size and velocity, mechanical patternation for liquid water flux, and planar laser induced fluorescence (PLIF) with acetone-seeding for gaseous fuel/air mixing characterization. Five scaled candidate fuel nozzle designs, in addition to a scaled bill-of-materials nozzle, were then successfully evaluated in an atmospheric pressure burner rig. The nozzles were evaluated for performance with natural gas, hydrogen/natural gas blends, and pure hydrogen. For 100% hydrogen, the nozzles were evaluated with and without water injection. Optical and infrared imaging of the flame and fuel nozzle was captured. NOx emissions were sampled from fixed emissions probes. The results show measurable differences between the various designs, and the data was used to down-select the two most promising designs to advance to future full pressure rig testing. Results from this study have cleared the current production FT4000 engines with dual fuel nozzles to operate at baseload power on blends of hydrogen mixed with natural gas and water. Two promising nozzle designs have been developed to enable fully robust operation with up to 100% hydrogen. These nozzles require validation at full baseload operating conditions before they can be introduced to the field.

03 NATURAL GAS

The cluster decomposition of the configurational energy of multicomponent alloys

Abstract The cluster expansion method (CEM) is a widely used lattice-based technique in the study of multicomponent alloys. Despite its prevalent use, a clear understanding of expansion terms is lacking. We present a modern mathematical formalism of the CEM and introduce thecluster decomposition—a unique and basis-independent decomposition for functions of the atomic configuration in a crystal. We identify the cluster decomposition as an invariant ANOVA decomposition; and demonstrate how functional analysis of variance and sensitivity analysis can be used to interpret interactions among species. Furthermore, we show how the mathematical structure of the cluster decomposition enables numerical evaluation that scales with the number of clusters and is independent of the number of species. Overall, our work enables rigorous interpretations of interactions among species, provides opportunities to explore parameter estimation beyond linear regression, introduces a numerical efficient implementation, and enables analysis of cluster expansions based on established mathematical and statistical principles.

Chemistry

Solar Heat for Industrial Processes: Integration with Chemical Reactors

The integration of solar thermal systems with chemical reactors has been proposed as part of a larger effort to develop and deploy solar heat for industrial processes (SHIP) technologies. A strong motivation for SHIP processes and technologies is the potential for high thermal efficiency coupled with low-cost thermal energy storage (TES) which can enable commercial deployment of such systems. While there are different ways to categorize SHIP technologies, one important such distinction is between directly irradiated systems and indirect off-sun process driven by a SHIP system. While directly irradiated systems can provide high thermal efficiencies and high fluxes, they usually require complex engineering solutions due to the need for redesigning the established processes and unit operations. In most cases, it is also more challenging to couple such a process to a TES system, losing some of the benefits of SHIP. On the other hand, using a SHIP system to drive an industrial process off-sun can allow better integration with existing process chains, easier TES capabilities, and potential for more applications fitting a specific SHIP technology. However, the integration of SHIP systems with the industrial processes is not fully explored in detail, especially in the case of high-temperature processes such as reforming, cracking, cement manufacturing, and iron/steelmaking. Many of these systems require heating fluxes of >50 kW/m^2, supplied via combustion of hydrocarbons in a fire box and benefitting from radiative heat transfer between the flue gases and the reaction zones. As such, using SHIP systems for such processes is more complex than providing the same thermal input in the form of a heat transfer medium (HTM) entering the reactor, kiln, or furnace. Moreover, in case convective heat transfer using SHIP is envisioned, for example using supercritical CO2 as the HTM from a particle receiver, the thermal integration might be more challenging than initially envisioned: lower heat transfer coefficients and limited approach temperature might require large flow rates, causing a mismatch between the process thermal requirements and the thermal capacity of the SHIP system. In addition, even if the heat exchange between SHIP and reactor is effective, there is still a cold leg HTM at the reaction temperature or slightly below it. Chemical plants usually include a set of heat exchangers, heat recovery steam generators, and even power generation units - in a tightly integrated design - to recover the flue gases which are eventually vented. With SHIP systems mostly operating on a closed HTM loop, bottoming the cold leg is crucial. In this talk, we will present different modeling results for a variety of syngas production reactions, using catalytic and chemical looping processes, and discuss some of the challenges and design considerations for off-sun chemical reactors using SHIP systems.

14 SOLAR ENERGY

Amazonian fog harbors viable microbes

Fog formation over tropical forests remains poorly characterized, despite its potential role in bioaerosol dispersion and ecosystem processes. Here, we analyzed fog samples collected at the Amazon Tall Tower Observatory using flow cytometry and culture-based techniques to characterize viable microbial communities. Microbial cell concentrations varied over an order of magnitude across 13 fog events, reaching up to 8 × 104 cells per ml of fog water. Flow cytometry consistently detected metabolically active cells, while culturing and mass spectrometry-based identification yielded eight viable bacterial species and seven fungal taxa. The bacteria Serratia marcescens, Ralstonia pickettii and Sphingomonas paucimobilis exhibited seasonal variations in prevalence. The fungal species identified were primarily mesophilic saprophytes and endophytes, commonly associated with soil and plant surfaces. Our findings indicate that fog harbors viable microbes, including Serratia marcescens and Ralstonia pickettii, which may imply a relevance of fog for microbial dispersal, colonization and nutrient cycling in the Amazon rainforest.

Godoi, Ricardo H. (ORCID:0000000247744870)

Methanol mixing−controlled compression ignition enabled via homogeneous charge compression ignition of dimethyl ether through catalytic decomposition of methanol

Methanol is a potentially attractive fuel for marine and off−road engines owing to its availability at bunkering and global distribution locations. Although methanol is well−distributed worldwide, its fuel chemistry and ignition properties make it poorly suited as a direct drop−in replacement for diesel fuel in compression−ignition engines. However, industrial processes are regularly used to convert methanol, via catalytic dehydration, to dimethyl ether (DME) over nonprecious metal catalysts. This chemical conversion can occur at relatively low pressures, temperatures, and catalyst space velocities, highlighting a potential opportunity to generate DME via onboard catalytic dehydration of methanol. DME’s fuel kinetic and ignition properties for compression ignition are much more favorable than those of methanol or even diesel fuel, but DME is more challenging than diesel fuel or methanol to pump, store, and deliver through conventional diesel fueling injection hardware. Thus, a potential opportunity exists to use the ignition and kinetic properties of DME, with the transportation and delivery advantages of methanol, in a methanol−fueled mixing−controlled compression−ignition engine. The present work explores performance, combustion behavior, and emissions reduction opportunities for methanol mixing−controlled combustion, enabled by a HCCI of DME that represents a small fraction of the total fuel energy that can be generated onboard via catalytic dehydration of methanol.

Splitter, Derek [ORNL] (ORCID:0000000174044047)

DNA Crystals as a Template for Patterned Functional Materials

DNA nanotechnology offers a wide toolkit of molecular functionalities and scales, including intricate motifs less than 10 nm and periodic structures exceeding 100 µm. At larger scales, however, there are often significant tradeoffs for DNA structures, namely stability and mechanical strength. This work describes the design, synthesis, and characterization of a functionalized DNA crystal. Using a ligated DNA crystal grants significant freedom for various functional materials to be applied, in this case, semiconducting cadmium sulfide and palladium metal. Properties investigated in this study include stability, mechanical strength, and optoelectronic properties such as photoluminescence (PL) and electric conductivity. Significant changes are observed based on the functional material applied to DNA crystals. The Young's modulus of the crystal varies by about five orders of magnitude when functionalized with palladium. PL and semiconductive behaviors were observed when cadmium sulfide was attached. These crystals represent an expansion of the capabilities of DNA structures at these length scales, and additionally a platform for future studies exchanging the materials or altering the ligation scheme.

CdS

Evaluating technology upgrades as a complement to traditional bill assistance programs

State programs to improve energy affordability and reduce energy burden (the share of income spent on energy) could mitigate concerns about rising electricity prices. Many states offer bill assistance and rebates for weatherization and rooftop solar to income-qualifying households. Here, we analyse how these approaches may complement one another to improve energy affordability. Results illustrate trade offs between program costs and energy burden reduction, as well as between a program’s upfront and ongoing costs. Generally, the three strategies complement one another to improve energy affordability at lower net present cost than bill assistance alone, with varying effects across regions. Weatherization can reduce the solar installation capacity needed, and both together can reduce or eliminate ongoing reliance on bill assistance. Under full uptake among cost-effective households, fully rebated weatherization and solar rebated at $0.48/Watt, combined with bill assistance, yield the same modelled net present cost as bill assistance alone while reducing the share of low-income owner-occupied households with high energy burdens from 66% to 19%, compared with 34% under bill assistance alone. Absent tax credits, weatherization still reduces energy burden and bill assistance program costs, whereas solar may not be cost-competitive.

Forrester, Sydney P