Search NASA⌕ Search

SEARCH · Search NASA

Results for “Acceleration methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,207 records · Page 67

Moment Representation of Regularized Lattice Boltzmann Methods on NVIDIA and AMD GPUs

The lattice Boltzmann method is a highly scalable Navier-Stokes solver that has been applied to flow problems in a wide array of domains. However, the method is bandwidth-bound on modern GPU accelerators and has a large memory footprint. In this paper, we present new 2D and 3D GPU implementations of two different regularized lattice Boltzmann methods, which are not only able to achieve an acceleration of ∼ 1.4 × w.r.t. reference lattice Boltzmann implementations but also reduce the memory requirements by up to 35% and 47% in 2D and 3D simulations respectively. These new approaches are evaluated on NVIDIA and AMD GPU architectures.

Valero Lara, Pedro↗

Space charge studies in FFAG using the tracking code Zgoubi

A method is implemented in Zgoubi that allows the computation of space charge effects in 2D distributions and with some restrictions in 3D distributions. It relies on decomposing field maps or analytical elements into slices and applying a space charge kick to the particles. The aim of this study is to investigate the accuracy of this technique, its limitations/advantages by comparisons with other linear/nonlinear computation methods and codes, and to apply it to high power fixed field ring design studies.

43 PARTICLE ACCELERATORS↗

Production Review of Accelerator-Based Medical Isotopes

The production of reactor-based medical isotopes is fragile, which has meant supply shortages from time to time. This paper reviews alternative production methods in the form of cyclotrons, linear accelerators and neutron generators. Finally, the status of the production of medical isotopes in China is described.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Improved Criticality Convergence via a Modified Monte Carlo Power Iteration Method

Monte Carlo transport codes typically estimate the fundamental mode of a nuclear system via a power iteration method. If the eigenvalues of the system are denoted $k$ 1 , $k$ 2 , $k$ 3 ..." with $k$ 1 > $k$ 2 ≥ $k$ 3 ≥ $k$ 4 ··· > 0, and corresponding eigenfunctions Ψ $m$ , it is well known that the Ψ $m$ mode disappears after $n$ iterations as ($k$ $m$ /$k$ 1 ) $n$ . When the dominance ratio $k$ 2 /$k$ 1 is near unity, the convergence to Ψ 1 can be very slow, even if the convergence to $k$ 1 is fast. The convergence to Ψ 1 sometimes can be dramatically improved by estimating Ψ 1 and Ψ 2 . A Monte Carlo implementation of the modified power iteration method requires the neutrons representing Ψ 2 to have both negative and positive weights because Ψ 2 cannot be of one sign. Thus, Ψ 2 is a sum of negatively and positively weighted neutrons. Instead of summing using point detector methods, a new simple binning procedure accelerates convergence to Ψ 1 .

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

SU-E-T-512: Electromagnetic Simulations of the Dielectric Wall Accelerator

Purpose: To characterize and parametrically study the key components of a dielectric wall accelerator through electromagnetic modeling and particle tracking. Methods: Electromagnetic and particle tracking simulations were performed using a commercial code (CST Microwave Studio, CST Inc.) utilizing the finite integration technique. A dielectric wall accelerator consists of a series of stacked transmission lines sequentially fired in synchrony with an ion pulse. Numerous properties of the stacked transmission lines, including geometric, material, and electronic properties, were analyzed and varied in order to assess their impact on the transverse and axial electric fields. Additionally, stacks of transmission lines were simulated in order to quantify the parasitic effect observed in closely packed lines. Particle tracking simulations using the particle-in-cell method were performed on the various stacks to determine the impact of the above properties on the resultant phase space of the ions. Results: Examination of the simulation results show that novel geometries can shape the accelerating pulse in order to reduce the energy spread and increase the average energy of accelerated ions. Parasitic effects were quantified for various geometries and found to vary with distance from the end of the transmission line and along the beam axis. An optimal arrival time of an ion pulse relative to the triggering of the transmission lines for a given geometry was determined through parametric study. Benchmark simulations of single transmission lines agree well with published experimental results. Conclusion: This work characterized the behavior of the transmission lines used in a dielectric wall accelerator and used this information to improve them in novel ways. Utilizing novel geometries, we were able to improve the accelerating gradient and phase space of the accelerated particle bunch. Through simulation, we were able to discover and optimize design issues with the device at low cost. Funding: Morgridge Institute for Research, Madison WI; Conflict of Interest: Dr. Mackie is an investor and board member at CPAC, a company developing compact accelerator designs similar to those discussed in this work, but designs discussed are not directed by CPAC. Funding: Morgridge Institute for Research, Madison WI; Conflict of Interest: Dr. Mackie is an investor and board member at CPAC, a company developing compact accelerator designs similar to those discussed in this work, but designs discussed are not directed by CPAC.

43 PARTICLE ACCELERATORS↗

N Jettiness: An Inclusive Event Shape to Veto Jets

Jet vetoes are essential in many analyses at the LHC and Tevatron. Typical signals have a specific number of hard jets or leptons, while backgrounds have additional jets. Vetoing undesired jets efficiently discriminates signal and background. For a sample with {>=}N jets, the veto to give N energetic jets defines an 'exclusive' N-jet cross section. This strongly restricts the phase space and causes large double logarithms in perturbation theory that must be summed. Jet vetoes are typically implemented using jet algorithms, yielding complicated phase-space restrictions, and reliance on leading-log parton-shower Monte Carlo simulations. We introduce a global event shape 'N jettiness' {tau}{sub N}, which is defined for events with N signal jets. Requiring {tau}{sub N}<<1 constrains radiation between the signal jets and provides a theoretically well-controlled jet veto. N jettiness yields a factorization formula with inclusive jet and beam functions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

AI-Driven Accelerated Inclusion Analysis for Energy Efficient Steelmaking (Final CRADA Report)

This was a collaborative effort between Lawrence Livermore National Security, LLC (LLNS) as manager and operator of Lawrence Livermore National Laboratory (LLNL) and ArcelorMittal USA Research LLC (“ArcelorMittal” as the Participant), to use scanning electron microscopy (SEM) images, computer vision and machine learning methods, and high-performance computing to accelerate the inclusion analysis process of liquid steel so that new methods can be used for near-real time process control on the shop floor.

36 MATERIALS SCIENCE↗

MIVOC method with temperature control

The Heavy Ion Medical Accelerator in Chiba at the National Institute of Radiological Sciences has been used for cancer therapy, physics, and biology experiments since 1994. Its ion sources produce carbon ion for cancer therapy. They also produce various ions (H{sup +}-Xe{sup 21+}) for physics and biology experiments. Most ion species are produced from gases by an 18 GHz electron cyclotron resonance ion source. However, some of ion species is difficult to produce from stable and secure gases. Such ion species are produced by the sputtering method. However, it is necessary to reduce material consumption rate as much as possible in the case of rare and expensive stable isotopes. We have selected ''metal ions from volatile compounds method'' as a means to solve this problem. We tested a variety of compounds. Since each compound has a suitable temperature to obtain the optimum vapor pressure, we have developed an accurate temperature control system. We have produced ions such as {sup 58}Fe{sup 9+}, Co{sup 9+}, Mg{sup 5+}, Ti{sup 10+}, Si{sup 5+}, and Ge{sup 12+} with the temperature control.

43 PARTICLE ACCELERATORS↗

SU-D-17A-02: Four-Dimensional CBCT Using Conventional CBCT Dataset and Iterative Subtraction Algorithm of a Lung Patient

Purpose: The Iterative Subtraction Algorithm (ISA) method generates retrospectively a pre-selected motion phase cone-beam CT image from the full motion cone-beam CT acquired at standard rotation speed. This work evaluates ISA method with real lung patient data. Methods: The goal of the ISA algorithm is to extract motion and no- motion components form the full reconstruction CBCT. The workflow consists of subtracting from the full CBCT all of the undesired motion phases and obtain a motion de-blurred single-phase CBCT image, followed by iteration of this subtraction process. ISA is realized as follows: 1) The projections are sorted to various phases, and from all phases, a full reconstruction is performed to generate an image CTM. 2) Generate forward projections of CTM at the desired phase projection angles, the subtraction of projection and the forward projection will reconstruct a CTSub1, which diminishes the desired phase component. 3) By adding back the CTSub1 to CTm, no motion CBCT, CTS1, can be computed. 4) CTS1 still contains residual motion component. 5) This residual motion component can be further reduced by iteration.The ISA 4DCBCT technique was implemented using Varian Trilogy accelerator OBI system. To evaluate the method, a lung patient CBCT dataset was used. The reconstruction algorithm is FDK. Results: The single phase CBCT reconstruction generated via ISA successfully isolates the desired motion phase from the full motion CBCT, effectively reducing motion blur. It also shows improved image quality, with reduced streak artifacts with respect to the reconstructions from unprocessed phase-sorted projections only. Conclusion: A CBCT motion de-blurring algorithm, ISA, has been developed and evaluated with lung patient data. The algorithm allows improved visualization of a single phase motion extracted from a standard CBCT dataset. This study has been supported by National Institute of Health through R01CA133539.

60 APPLIED LIFE SCIENCES↗

Electron Multi-Beams (Electron Grids, Electron Lattices and Electron Grates): New Elements for Accelerators

Since the initial proposal in 1990s, the method of electron lenses has been successfully developed and employed at the high energy particle colliders, like Tevatron and RHIC. Here we propose a new set of electron multi beam elements (electron grids, electron lattices, electron grates and other) which employ many beams in various spatial configurations, with possible time varying currents. We present major principles of operation and generation of such systems and briefly discuss a set of possible applications in accelerators.

43 PARTICLE ACCELERATORS↗

Real-Time 3D Image Guidance Using a Standard LINAC: Measured Motion, Accuracy, and Precision of the First Prospective Clinical Trial of Kilovoltage Intrafraction Monitoring–Guided Gating for Prostate Cancer Radiation Therapy

Purpose: Kilovoltage intrafraction monitoring (KIM) is a new real-time 3-dimensional image guidance method. Unlike previous real-time image guidance methods, KIM uses a standard linear accelerator without any additional equipment needed. The first prospective clinical trial of KIM is underway for prostate cancer radiation therapy. In this paper we report on the measured motion accuracy and precision using real-time KIM-guided gating. Methods and Materials: Imaging and motion information from the first 200 fractions from 6 patient prostate cancer radiation therapy volumetric modulated arc therapy treatments were analyzed. A 3-mm/5-second action threshold was used to trigger a gating event where the beam is paused and the couch position adjusted to realign the prostate to the treatment isocenter. To quantify the in vivo accuracy and precision, KIM was compared with simultaneously acquired kV/MV triangulation for 187 fractions. Results: KIM was successfully used in 197 of 200 fractions. Gating events occurred in 29 fractions (14.5%). In these 29 fractions, the percentage of beam-on time, the prostate displacement was >3 mm from the isocenter position, reduced from 73% without KIM to 24% with KIM-guided gating. Displacements >5 mm were reduced from 16% without KIM to 0% with KIM. The KIM accuracy was measured at <0.3 mm in all 3 dimensions. The KIM precision was <0.6 mm in all 3 dimensions. Conclusions: Clinical implementation of real-time KIM image guidance combined with gating for prostate cancer eliminates large prostate displacements during treatment delivery. Both in vivo KIM accuracy and precision are well below 1 mm.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Diaphragm flange and method for lowering particle beam impedance at connected beam tubes of a particle accelerator

A diaphragm flange for connecting the tubes in a particle accelerator while minimizing beamline impedance. The diaphragm flange includes an outer flange and a thin diaphragm integral with the outer flange. Bolt holes in the outer flange provide a means for bolting the diaphragm flange to an adjacent flange or beam tube having a mating bolt-hole pattern. The diaphragm flange includes a first surface for connection to the tube of a particle accelerator beamline and a second surface for connection to a CF flange. The second surface includes a recessed surface therein and a knife-edge on the recessed surface. The diaphragm includes a thickness that enables flexing of the integral diaphragm during assembly of beamline components. The knife-edge enables compression of a soft metal gasket to provide a leak-tight seal.

43 PARTICLE ACCELERATORS↗

A multi-beamlet analysis of the MITICA accelerator

The thermo-mechanical analysis and the mechanical design of the accelerator of MITICA (i.e. the full size prototype of the ITER neutral beam injector under construction at RFX [1]) are based on the calculation of the power deposition induced by particle impacts. This calculation is performed by EAMCC [2], a relativistic particle tracking code based on the Monte-Carlo method for describing collisions inside the accelerator, under prescribed electric and magnetic fields. The magnetic field maps are produced by 3D codes, while the electric field maps come from the 2D axi-symmetric code SLACCAD [3]. In order to perform a multi-beamlet analysis, which allows to take into account the beamlet-beamlet repulsion, and to consider other effects neglected under the hypothesis of axi-symmetric beam, a fully 3D version of the code is required. In this paper, a modified version of EAMCC, fully 3D, capable of modifying the mesh of the 3D maps and of dealing with uneven meshes is presented. A finer mesh is used just in the regions where a more detailed description of the fields is required, for a more realistic simulation. A comparison between the original code and the modified version is presented at first, as a validation of the modifications introduced in the latter. Subsequently, the main results of a single-beamlet analysis performed with the two versions of the code are shown and the differences between the 2D and the 3D simulations discussed. The last part is dedicated to the multi-beamlet simulation of the accelerator.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Technical Note: Motion-perturbation method applied to dosimetry of dynamic MLC target tracking—A proof-of-concept

Purpose: Previous studies show that dose to a moving target can be estimated using 4D measurement-guided dose reconstruction based on a process called virtual motion simulation, or VMS. A potential extension of VMS is to estimate dose during dynamic multileaf collimator (MLC)-tracking treatments. The authors introduce a modified VMS method and quantify its performance as proof-of-concept for tracking applications. Methods: Direct measurements with a moving biplanar diode array were used to verify accuracy of the VMS dose estimates. A tracking environment for variably sized circular MLC apertures was simulated by sending preprogrammed control points to the MLC while simultaneously moving the accelerator treatment table. Sensitivity of the method to simulated tracking latency (0–700 ms) was also studied. Potential applicability of VMS to fast changing beam apertures was evaluated by modeling, based on the demonstrated dependence of the cumulative dose on the temporal dose gradient. Results: When physical and virtual latencies were matched, the agreement rates (2% global/2 mm gamma) between the VMS and the biplanar dosimeter were above 96%. When compared to their own reference dose (0 induced latency), the agreement rates for VMS and biplanar array track closely up to 200 ms of induced latency with 10% low-dose cutoff threshold and 300 ms with 50% cutoff. Time-resolved measurements suggest that even in the modulated beams, the error in the cumulative dose introduced by the 200 ms VMS time resolution is not likely to exceed 0.5%. Conclusions: Based on current results and prior benchmarks of VMS accuracy, the authors postulate that this approach should be applicable to any MLC-tracking treatments where leaf speeds do not exceed those of the current Varian accelerators.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗