Search NASA⌕ Search

SEARCH · Search NASA

Results for “Accelerators, Instrumentation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,207 records · Page 67

Present and Future of Central Production With STAR Detector at RHIC

The present status and future of the physics program of Central Production using the STAR detector at RHIC are described. The program focuses on particle production in the Double Pomeron Exchange (DPE) process. Forward protons from the DPE interaction are detected in the Roman Pot system installed at 55.5 m and 58.5 m on both sides of the STAR interaction point. The recoil system of charged particles from the DPE process is measured in the STAR Time Projection Chamber (TPC). The first data were taken during the 2009 RHIC Run 9 using polarized proton-proton collisions at {radical}(s) 200 GeV. The preliminary spectra of two pion and four pion invariant mass reconstructed by STAR TPC in central region of pseudo-rapidity |{eta}|<1, are presented. Plans to take data with the current system at {radical}(s) = 500 GeV and plans to upgrade the forward proton tagging system, so that it can reach higher masses and obtain large data samples to allow searching for glueballs that could be produced in the DPE process, are also discussed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Forward Di-Hadron Correlations in d+Au Collisions in PHENIX

Suppression in nuclear modification factors have been observed in past measurements at RHIC at {radical}(s{sub NN}) = 200 GeV in deuteron-gold collisions. Gluon saturation has been proposed as one among many explanations for this effect. Due to the gluon densities at low Bjoerken-x in the Lorentz-contracted gold nuclei, saturation effects are expected to be enhanced in the forward direction of the deuteron. Two new electromagnetic calorimeters have been incorporated into the PHENIX experiment covering pseudo-rapidities of 3.1<{eta}<3.7(3.9). We have used these calorimeters to study forward di-hadron correlations, probing parton momentum fractions down to x{sub Bj}{approx_equal}10{sup -3} in the gold nuclei. This analysis is based on the 2008 d+Au data with an integrated luminosity of 80 nb{sup -1}.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Neutron Structure Function from BoNuS

The BoNuS experiment at Jefferson Lab's Hall B measured the structure of the quasi-free neutron via electron scattering off a deuteron target and detection of the slowly recoiling spectator protonat very backward angles. The very low momentum backward recoiling protons were detected by a novel radial time projection chamber featuring gas electron multipliers, augmenting the CLAS detector. Data were taken successfully in the Fall of 2005.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurement of optical emission from the hydrogen plasma of the Linac4 ion source and the SPL plasma generator

At CERN, a non caesiated H{sup -} ion volume source derived from the DESY ion source is being commissioned. For a proposed High Power Superconducting Proton Linac (HP-SPL), a non caesiated plasma generator was designed to operate at the two orders of magnitude larger duty factor required by the SPL. The commissioning of the plasma generator test stand and the plasma generator prototype are completed and briefly described. The 2 MHz RF generators (100 kW, 50 Hz repetition rate) was successfully commissioned; its frequency and power will be controlled by arbitrary function generators during the 1 ms plasma pulse. In order to characterize the plasma, RF-coupling, optical spectrometer, rest gas analyzer and Langmuir probe measurements will be used. Optical spectrometry allows direct comparison with the currently commissioned Linac4 H{sup -} ion source plasma. The first measurements of the optical emission of the Linac4 ion source and of the SPL plasma generator plasmas are presented.

43 PARTICLE ACCELERATORS↗

Baryon spectroscopy at CLAS and CLAS12

The N* programme at CLAS in Jefferson Lab is dedicated to the study of the spectrum of baryon resonances and the search for missing resonances. Recent developments in polarized beams and targets at CLAS have made it possible to measure many of the single and double polarization observables which are necessary to disentangle the contributing processes. In particular, CLAS is well on the way to making the first complete measurement on pseudoscalar meson production. The current status of the N* program is presented together with preliminary results from recently completed experiments. A brief overview of the hadron spectroscopy capabilities of the upgraded CLAS12 detector is also be presented, with emphasis on the plans for a tagged, quasi real photon beam.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Meson Spectroscopy at CLAS and CLAS12

We report on meson spectroscopy using the CLAS at Jefferson Lab. We study photo-production of exotic mesons and strangeonia on the largest data sample ever to be produced at photon energies of about 5 GeV. We also describe an experiment to continue meson spectroscopy at CLAS12 (CLAS energy upgrade) using electroproduction at very low Q{sup 2}(''quasireal photons'') up to photon energies of 10 GeV.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A simple approximation for the current-voltage characteristics of high-power, relativistic diodes

A simple approximation for the current-voltage characteristics of a relativistic electron diode is presented. The approximation is accurate from non-relativistic through relativistic electron energies. Although it is empirically developed, it has many of the fundamental properties of the exact diode solutions. The approximation is simple enough to be remembered and worked on almost any pocket calculator, so it has proven to be quite useful on the laboratory floor.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ion concentration ratio measurements of ion beams generated by a commercial microwave electron cyclotron resonance plasma source

A commercially available electron cyclotron resonance (ECR) plasma source (GenII Plasma Source, tectra GmbH) is widely used for surface processing. This plasma source is compatible with ultrahigh vacuum systems, and its working pressure is relatively low, around 10 –6 –10 –4 Torr even without differential pumping. Here, we report ion flux concentration ratios for each ion species in an ion beam from this source, as measured by a mass/energy analyzer that is a combination of a quadrupole mass spectrometer, an electrostatic energy analyzer, and focusing ion optics. In this study, the examined beams were those arising from plasmas produced from feed gases of H 2 , D 2 , N 2 , O 2 , Ar, and dry air over a range of input power and working pressures. H 2 (D 2 ) plasmas are widely used for nuclear fusion applications and, hence, the ion concentration ratios of H + , H 2 + , and H 3 + reported here will be useful information for research that applies this plasma source to well-controlled plasma-material interaction studies. Ion energy distributions, stability of operation, and impurity concentrations were also assessed for each of the plasma species investigated.

47 OTHER INSTRUMENTATION↗

Calibration of photoelastic modulator based dichrometers: maintaining constant phase across the spectrum

Photoelastic modulators can alter the polarization state of a beam of ultraviolet, visible or infrared photons by means of periodic stress-induced differences in the refractive index of a transparent material that forms the optical element of the device and is isotropic in the absence of stress. Furthermore, they have found widespread application in instruments that characterize or alter the polarization state of a beam in fields as diverse as astronomy, structural biology, materials science and ultraviolet lithography for the manufacture of nano-scale integrated circuits. Measurement of circular dichroism, the differential absorption of left- and right circularly polarized light, and of strain-induced birefringence of optical components are major applications. Instruments using synchrotron radiation and photoelastic modulators with CaF 2 optical elements have extended circular dichroism measurements down to wavelengths of about 130 nm in the vacuum ultraviolet. Maintaining a constant phase shift between two orthogonal polarization states across a spectrum requires that the amplitude of the modulated stress be changed as a function of wavelength. For commercially available photoelastic modulators, the voltage that controls the amplitude of modulation required to produce a specified phase shift, which is a surrogate for the stress modulation amplitude, has been shown to be an approximately linear function of wavelength in the spectral region where the optical element is transparent. But, extrapolations of such straight lines cross zero voltage at a non-zero wavelength, not at zero-wavelength. For modulators with calcium fluoride and fused silica optical elements, the zero-crossing wavelength is always in the spectral region where the optical element of the modulator strongly absorbs the incident radiation, and at a wavelength less than the longest-wavelength apparent resonance deduced from experimental values of the refractive index fit to the Sellmeier equation. Using a model that relates the refractive indices of a stressed optical element to the refractive index of its unstressed state, an expression for the modulator control voltage was derived that closely fits the experimental data. Our result provides a theoretical rational for the apparently linear constant-phase programming voltage, and thus provides theoretical backing for the calibration procedure frequently used for these modulators. Lastly there are other factors that can influence the calibration of a photoelastic modulator, including temperature and atmospheric pressure, are discussed briefly.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Results from a Prototype Chicane-Based Energy Spectrometer for a Linear Collider

The International Linear Collider (ILC) and other proposed high energy e{sup +}e{sup -} machines aim to measure with unprecedented precision Standard Model quantities and new, not yet discovered phenomena. One of the main requirements for achieving this goal is a measurement of the incident beam energy with an uncertainty close to 10{sup -4}. This article presents the analysis of data from a prototype energy spectrometer commissioned in 2006-2007 in SLAC's End Station A beamline. The prototype was a 4-magnet chicane equipped with beam position monitors measuring small changes of the beam orbit through the chicane at different beam energies. A single bunch energy resolution close to 5 {center_dot} 10{sup -4} was measured, which is satisfactory for most scenarios. We also report on the operational experience with the chicane-based spectrometer and suggest ways of improving its performance.

43 PARTICLE ACCELERATORS↗

{Lambda}-p femtoscopy in collisions of Ar+KCl at 1.76A GeV

Results on {Lambda}p femtoscopy are reported at the lowest energy so far. At a beam energy of 1.76A GeV, the reaction Ar+KCl was studied with the High Acceptance Di-Electron Spectrometer (HADES) at SIS18/GSI. A high-statistics and high-purity {Lambda} sample was collected, allowing for the investigation of {Lambda}p correlations at low relative momenta. The experimental correlation function is compared to corresponding model calculations allowing the determination of the space-time extent of the {Lambda}p emission source. The {Lambda}p source radius is found to be slightly smaller than the pp correlation radius for a similar collision system. The present {Lambda}p radius is significantly smaller than that found for Au+Au/Pb+Pb collisions in the AGS, SPS, and RHIC energy domains but larger than that observed for electroproduction from He. Taking into account all available data, we find the {Lambda}p source radius to increase almost linearly with the number of participants to the power of one-third.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Injection of electron beams into two laser wakefields and generation of electron rings

Throughout this work, mutual injection of electron beams into two laser plasma wakefields was observed experimentally when driving laser pulses interfered in plasma at a small crossing angle and were slightly relatively delayed, approximately by one pulse duration. Particle-in-cell simulations revealed that the mutual injection was sensitive to the spatial overlap of the laser pulses, which therefore could be used to control the mutual injection. The dual synchronized, femtosecond electron beams are potentially useful for pump-probe experiments in ultrafast science. In addition, out-of-axis ring-shaped electron beams were detected in both experiments and simulations.

47 OTHER INSTRUMENTATION↗

Azimuthal Correlations of Forward Dihadrons in d+Au Collisions at RHIC in the Color Glass Condensate

We present a good description of recent experimental data on forward dihadron azimuthal correlations measured in deuteron-gold collisions at the BNL Relativistic Heavy Ion Collider (RHIC), where monojet production has been observed. Our approach is based on the color glass condensate theory for the small-x degrees of freedom of the nuclear wave function, including the use of nonlinear evolution equations with running QCD coupling. Our analysis provides further evidence for the presence of saturation effects in RHIC data.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

New Measurement of the {pi}{sup 0} Radiative Decay Width

High precision measurements of the differential cross sections for {pi}{sup 0} photoproduction at forward angles for two nuclei, {sup 12}C and {sup 208}Pb, have been performed for incident photon energies of 4.9-5.5 GeV to extract the {pi}{sup 0}{yields}{gamma}{gamma} decay width. The experiment was done at Jefferson Lab using the Hall B photon tagger and a high-resolution multichannel calorimeter. The {pi}{sup 0}{yields}{gamma}{gamma} decay width was extracted by fitting the measured cross sections using recently updated theoretical models for the process. The resulting value for the decay width is {Gamma}({pi}{sup 0}{yields}{gamma}{gamma})=7.82{+-}0.14(stat){+-}0.17(syst) eV. With the 2.8% total uncertainty, this result is a factor of 2.5 more precise than the current Particle Data Group average of this fundamental quantity, and it is consistent with current theoretical predictions.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

ERL Timing and optimized CBETA models

This project develops a method of finding instrument settings that minimize the power load on accelerating radio-frequency (RF) cavities in an energy recovery linac (ERL). A general symmetry theory, which has been developed in detail and was previously tested in simple ERL models, will be used to optimize more detailed models of the Cor nell Brookhaven ERL Test Accelerator (CBETA). CBETA specifications are detailed in Fig. 1. Due to the high overlap with previous work, this report briefly summarizes the relevant outcomes of older ERL symmetry models; however, the reader is encouraged to consult for a more comprehensive coverage of these topics. This report will focus primarily on extensions of symmetry modeling toward more complex systems, including multi particle beams or CBETA-specific cavity tracking.

43 PARTICLE ACCELERATORS↗

Fermilab PIP-II CDS & CM Cryogenic Controls System

Details on Final design for Cryogenic Electrical & Controls System for Fermilab' s next-gen particle accelerator PIP-II. Electrical Controls System includes instrumentation and controls of Cryogenics Distribution System and Cryomodules. Design includes Siemens PCS7 Controls System with 26 Remote IO Rittal Cabinets and 48 Relay Racks for Temperature Readouts, Valve Positioners, Level, Heater Controls etc. Electrical Drawings and Design have been completed with focus now on fabrication of the 26 Rittal Cabinets and 48 Relay Racks. All materials have been procured. EPICS will be used as a SCADA system communicating to S7 Controllers via OPC UA.

Patel, Pratik [Fermilab]↗

Silicon Detector Letter of Intent

This document presents the current status of SiD's effort to develop an optimized design for an experiment at the International Linear Collider. It presents detailed discussions of each of SiD's various subsystems, an overview of the full GEANT4 description of SiD, the status of newly developed tracking and calorimeter reconstruction algorithms, studies of subsystem performance based on these tools, results of physics benchmarking analyses, an estimate of the cost of the detector, and an assessment of the detector R&D needed to provide the technical basis for an optimised SiD.

43 PARTICLE ACCELERATORS↗